electrodynamic vibration test systems in order to operate in vertical and horizontal ... is build as...
TRANSCRIPT
Sy
ste
ms
Dy
na
mic
Te
st
Electrodynamic Vibration Test SystemsSW2-6200APP ( 6KN)SW2-6230APP ( 6KN)SW2-1240APP (10KN)SW2-2320APP (20KN)
SW2-2LS3-340APP (20KN)
Technical subject to changes without prior notice !
air cooled
6 - 20 kN
Index
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
Serial description 3
Power amplifier TGE series 4
The operation of RMS-Electrodynamic Test Systems 5
Digital Controller "Test Manager SWR 1200" 6
Combination with horizontal slip tables 7
Test fixtures and load-bearing platforms 8
RMS-vibration systems in temperature- /climatic chamber operation 9
Technical Data SW2-6200APP (6KN) 10
Technical Data SW2-6230APP (6KN) 12
Technical Data SW2-1240APP (10KN) 14
Technical Data SW2-2320APP (20KN) 16
Technical Data SW2-2LS3-340APP (20KN) 18
Page
2
Field of Applications
Air Cooled Design
Cooling Blower
High Overturning Moment
Automatic Payload Support
Standard Vertical and Horizontal Operation
High Protection Standard
Controller
The 6-20KN air cooled medium force shaker series is designed with a lightweight armature to test medium weight specimens. They are suitable forresonance determination, premature aging and fatigue testing of sensorsand electronic components as well as complete assemblies. Severalfeatures make these shakers series reliable and affordable for yourapplications.The shaker operates in a wide useful frequency range of 5 to 3500 Hz insine, random and shock mode. The shaker series provide different armaturediameters appropriate to the specimen size. Several features make theseshakers reliable and affordable systems for your applications.
The 6-20KN medium force shaker series and the TGE series power amplifierare totally air cooled, an important feature for easy installation andeconomical operation.
The 6-20 force shaker systems are optional equipped with a blower silencerthat significantly reduces the ambient noise.An advanced noise reduction is possible by an additional acousticenclosure.
The armature design incorporates the robust structures for top guidance anda unique roller-bearing for bottom guidance. The system is capable toprovide high overturning moments for testing products with a high centre ofgravity.
A superior automatic pneumatic load support system guarantees a fullnominal displacement with a maximum vertical load for test specimen andfixtures.
The 6-20KN medium force shaker series are air suspended in a rigid swivelframe in order to operate in vertical and horizontal configuration. The shakercan easily be moved in either vertical or a horizontal direction and can beused in combination with a slip table or environmental chamber with optionalthermal barrier.
A high standard protection system of interlock circuits ensures the best levelof protection for the operator, test specimens and the systems themselves.
All RMS Shaker Systems can be operated with the RMS controller “TestManager SWR1200”and with all third party Control Systems
The vibrators SW2-6200 APP up to SW2-2LS3-340APP
RMS Dynamic Test SystemsRMS Dynamic Test Systems 3
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
1 1
10
1
2
3
4
5 6 7 8
9
11
12
13
RMS amplifiers have a clear structureaccording to CE and additional Germanand European industrial standards
1 Fan2 Power modules3 Lead fuses4 Blower motor protection relay5 Mains connection6 Field coil connection7 Shaker connection8 Blower connection9 Reset button
10 Modul monitor11 Fuses12 Connection strip13 Link fuses
Legend
4
Power Amplifier
• 3
• 3
• U
• H
• H
• 100%
• 110 kHz
• Low
• Compact
• PLC
• Remote
• Very high
The systems are driven with a RMS power amplifier TGE series whichis build as a 19” width and 2000 mm standard height cabinet or as acompact 700 mm height case.
• Air cooled design in accordance to European Type ofProtection IP 53.
up to 160KVA output power in steps of 10KVA power modules
KVA power modules for low power shaker systems
sing latest MOSFET technology
igh efficiency
igh protection standards with a full range of system interlockcircuits ensures high reliability
compliance with international safety and EMC standards
switching frequency allow high signal bandwidth
harmonic distortion
stand alone-design including field/degaussing field supply
and EMI filter with free space for vibration controller or customer
instrumentation.
controlled using touch screen user interface
controllable
peak performance for shock and random tests
All RMS shaker systems comply with the German, and internationalsafety, EMI, EMC standards and the European Community directives:
• EU- Directive „Safety of machinery" 98/37/EWG• DIN EN ISO 12100-1 and -2 , Safety of machinery Basis• DIN EN 1050 Safety of machinery Principles for risk assessment• DIN EN 60204-1, Safety of machinery Electrical equipment of
machines• DIN EN 50178, Electronic equipment for use in power installations• DIN EN 61000-6-2 and -4, Electromagnetic compatibility ( EMC )
RMS Dynamic Test SystemsRMS Dynamic Test Systems 5
Off v1.02
StartConfiguration
OperationOutput current#
Stop
Current limit 53%50% 100%
SCP-System Control Panel
Typical 19-inch rack configuration with:- Power module TGE 10-4- SCP System Control Panel- Degaussing field supply
100%
CURRENT I peak
0
CURRENT Irms
0 100%
CURRENT limit 100%
23.08.01 11:26:18
OPERATION
Blower ON
Hydraulic OFF
Field Maximum ON
Amplifier ON
Release ON
Slip Table Mode DISABLEDExternal-Start DISABLED
100%
CURRENT I peak
0
CURRENT Irms
0 100%
CURRENT limit 100%
23.08.01 11:14:52
OFF
CURRENT LIMITinput 0-100 100 %
Field Maximum OFF
MIN MAX
Hydraulic OFF
OFF ONBlower OFF
OFF ONExternal-Start DISABLED
OFF ON
BACKService
The operation of RMS-Electrodynamic Test Systems
The SCP unit can be usedseparately as remote unit(Option)
SCP - System Control Panel- comfort configuration (optional) -recommended for larger systemconfigurations with slip table.The SCP - System Control Panel - providesinstant access to all essential systeminformation via touch screen input and LCDdisplay. Panel can be used remotly.
SCU System Control Unit - Standard equipment for amplifiers TGE 10-X -Microprocessor based amplifier / system control unit with LCD function display (monochrome) providesinstant access to essential information of the system as amplifier status, setting including interlocks andoutput current information. Remote function for amplifier start / stop included.
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
Digital Controller "Test Manager SWR 1200 and SWR 1220"
Field of application:
The SWR 1200 Test Manager is an intelligent controllerfor the activation of electrodynamic and servo hydraulicvibrator systems.With its modern microprocessor technology andergonomically designed software architecture it is the firstchoice of testing and R&D departments. It is a useful toolin enforcing the application of many international testspecifications (e.g. DIN EN 600 68-2, VDE, MIL, etc.)
Characteristics:The self-explanatory user interface (based on MS Windows) together with the modular upgrading concept are themain focuses of the SWR 1200. The Test Manager is networked (TCP/IP) and has comprehensive analysisfunctions.
Options:
The SWR 1200 Test Manager is availablewith the following options:• Basic software: sine, random, shock• Sine on random• Resonance mode• Road simulation• ActiveX interface• Test sequencing• Remote display software• 4 or 8 channel• and more......
Blockdiagram of a vibration system with controller
4a
STANDBY START
Test Manager SWR 1200
Power
ON
OFF
1 2 3 4 5 6 7 8 TEST
4
2
3
1
5
7
8
9
S o R SINE-SWEEP SHOCK RANDOM
6
REMOTE DISPL. RESONANCE R o R AktiveX
1010
4b
1.2.3.4.4a. 4b:5.6.7.8.9.
10.
Vibration GeneratorPower amplifier with or without Field Power SupplyTest Manager Controller SWRHost-PCHost-PC 2 Remote control unitPrinterNetworkEquipment under test (EUT), acceleration sensors connected (ICP-type)AccelerometerCharge amplifier - necessary when piezoelectric accelerometers used.Software
SHOCKSINE RANDOM RESONANCE
ActiveXTESTSEQUENZING
RANDOM ONRANDOM
SINE ONRANDOM
REMOTECONTROL
a
t
TIME HISTORY TEMP./CLIMATICCHAMBER CONTROL
Software applications
6
RMS Dynamic Test SystemsRMS Dynamic Test Systems
Field of application:
Characteristics:
Options:H
R
Horizontal slip tables extend the applications of vibration systems. A slip table isrequired in 3-axis tests where the operating position of the specimen is specified.The vertical axis (z) is tested on the shaker and the horizontal axes (x + y) on the sliptable. The shaker can be pivoted within its frame for this purpose.A slip table enables a test of very heavy or bulky specimen in a horizontal position.This combination is the perfect completion for specimens which have to be tested intheir original fitting position.
Vibrator and slip table are mounted on a common base element which is installed onair isolators to eliminate vibration transmission into the ground.The slip plate with mounting inserts slides on an oil film provided by a hydraulic unit.Our horizontal slip tables consist of the slip table plate, linear bearings guidance, thecoupling between shaker and plate and finally the main frame with integrated swivelframe and hydraulic supply.The slip tables are suitable for combination with a temperature or climatic chamber.
ydrostatic bearing design for enhanced guidance to support heavy payloadslead to a restrained movement, resulting in pure linear motion.(Type SWHxxx1)
egarding the application and the size and weight of the specimen,the hydrostatical guided slip table types can be optionally equipped withup to 7 bearings
•
•
Horizontal slip tables
7
Slip table base withV-bearings
Slip table base withhydrostatic bearings
•
•
•
•
V
G
S
A
arious slip table dimensions can be supplied for our different vibration systems.
rid design and thread dimensions can be selected.
uitable accessories are available for use in combination with atemperature/climatic chamber.
number of thermal barriers are available to protect the slip tableagainst heat and cold from the connected temperature chamber.
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
Test fixtures and load-bearing platforms
T-Form / L-Form(Series SWP 5000/6000)
Test fixtures,square, rectangular,round.
Series SWP 1000 / 2000
Series SWP 3000
Field of application:
Characteristics:
Options:
We use test fixtures made of magnesium- and aluminium cast plates. These fixtures can be directly bolted to themoving element of the vibrator. The specimen can be mounted by means of the threaded inserts in the plate.
A special multipart transmitter shaft with a thermal barrier is available for combined use with a temperature chamber.Fixtures with additional bearings are also available for our systems with more than 5 kN.
For additional information please contact RMS sales department at
Only a small number of test items can be fastened directly onto the mounting surface of the vibrator. Shape, size andtest position of the test items require custom-built fixtures.
8
RMS Dynamic Test SystemsRMS Dynamic Test Systems
RMS-vibration systems in temperature- /climatic chamber operation
Field of application:
Characteristics:
Options:
International test specifications of automobile and aircraftindustry demand combined stress of vibration andtemperature/climate. The challenge is to combine the vibrationsystem optimal with the temperature/ climatic chamber.
Due to our multi-functional interface between chamber andvibrator we accomplish an optimal sealing of thetemperature/climatic chamber and an effective temperatureprotection for the vibrator. Thus we ensure a perfectcombination with all well-known temperature climatic chambermanufacturers.
In close collaboration between our design engineers and thespecialists for climatic chambers we develop special solutionsfor the individual requirements of our customers.
9
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
Technical Data SW2-6200APP (6KN)
Usable slip tables
)*1 slip table types ending with: 1 = hydrostatic bearings, 0 = V-groove bearings )*2 incl. joint)*3 depending on the location of the payload on the table
10
RMS Dynamic Test SystemsRMS Dynamic Test Systems 11
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
Technical Data SW2-6230APP (6KN)
Usable slip tables
)*1 slip table types ending with: 1 = hydrostatic bearings, 0 = V-groove bearings )*2 incl. joint)*3 depending on the location of the payload on the table
12
RMS Dynamic Test SystemsRMS Dynamic Test Systems 13
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
Technical Data SW2-1240APP (10KN)
Usable slip tables
)*1 slip table types ending with: 1 = hydrostatic bearings, 0 = V-groove bearings )*2 incl. joint)*3 depending on the location of the payload on the table
14
RMS Dynamic Test SystemsRMS Dynamic Test Systems 15
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
Technical Data SW2-2320APP (20KN)
Usable slip tables
)*1 slip table types ending with: 1 = hydrostatic bearings, 0 = V-groove bearings )*2 incl. joint)*3 depending on the location of the payload on the table
16
RMS Dynamic Test SystemsRMS Dynamic Test Systems 17
RMS Dynamische PrüfsystemeRMS Dynamische Prüfsysteme
Technical Data SW2-2LS3-340APP (20KN)
Usable slip tables
)*1 slip table types ending with: 1 = hydrostatic bearings, 0 = V-groove bearings )*2 incl. joint)*3 depending on the location of the payload on the table
18
RMS Dynamic Test SystemsRMS Dynamic Test Systems 19
ANSCHRIFT / CONTACTRMS Regelungs- und MesstechnikDynamic Test SystemsGutenbergstrasse 2721465 Reinbek / HamburgGermanyTel.: +49 (0)40 727 603-0Fax: +49 (0)40 722 30 66
2008
HeadquartersHamburg / Germany
RMS worldwide distribution network
SW6-20KN-V1-E-38/10/19