e:iot文件夹spider67 mobilespider67 mobile user manual rev. 1.1 · 2019. 9. 1. · 1 1 quickstart...
TRANSCRIPT
-
User ManualELCO Spider67 Mobile SeriesIoT I/O Gateway
-
Content
1 Quick start...................................................................................................................................... 1
1.1 Hardware environment..................................................................................................... 1
1.2 Network environment........................................................................................................2
2 Product description.......................................................................................................................3
2.1 Product features.................................................................................................................4
2.2 Product model....................................................................................................................5
3 Basic hardware parameters........................................................................................................ 7
3.1 SPMB-16DIO data sheet..................................................................................................7
3.2 SPMB-04AIO data sheet..................................................................................................8
4 Hardware interface description.................................................................................................10
4.1 SPMB-16DIO function port description....................................................................... 10
4.1.1 SPMB-16DIO gateway........................................................................................10
4.1.2 SPMB-16DIO I/O port description.....................................................................10
4.1.3 SPMB-16DIO LED indicator description.......................................................... 11
4.1.4 SPMB-16DIO module description.....................................................................12
4.1.5 SPMB-16DIO I/O channel description..............................................................13
4.1.6 SPMB-16DIO power supply interface description..........................................14
4.1.7 SPMB-16DIO I/O module expansion instructions..........................................15
4.1.8 SPMB-16DIO SIM card operating instructions............................................... 15
4.2 SPMB-04AIO function interface description............................................................... 19
4.2.1 SPMB-04AIO series gateway............................................................................ 19
4.2.2 SPMB-04AIO series LED indicator description.............................................. 19
4.2.3 SPMB-04AIO series I/O Module description...................................................21
4.2.4 SPMB-04AIO series I/O Channel description.................................................21
4.2.5 SPMB-04AIO series power supply interface description.............................. 22
4.3 SPMB series of WiFi configuration operation description........................................23
4.4 Product Dimensions........................................................................................................25
4.4.1 SPMB-16DIO series............................................................................................25
-
4.4.2 SPMB-04AIO series............................................................................................ 25
5 Management platform operation description......................................................................... 26
5.1 User Login........................................................................................................................ 26
5.2 Group management function description....................................................................27
5.3 User management...........................................................................................................28
5.4 Introduction of the basic functions of the platform.....................................................30
5.4.1 Page layout description.......................................................................................30
5.4.2 Device management function description........................................................31
5.4.3 Configuration for gateway.................................................................................. 33
5.4.4 Configuration for I/O device............................................................................... 36
5.4.5 Cloud logic control function description........................................................... 39
5.5 Dashboard function description.................................................................................... 41
5.6 Alarm log function description....................................................................................... 44
5.7 Device binding function description..............................................................................44
5.8 Customize formula function description...................................................................... 45
6 FOTA.............................................................................................................................................47
7 Appendix.......................................................................................................................................47
7.1 Glossary............................................................................................................................47
7.2 Legal notes.......................................................................................................................47
-
1
1 Quick startThe purpose of this manual is to help users quickly get familiar with and understand how
to use the Spider67 Mobile series, and use the tools and application management
platform to achieve user data collection and monitoring.
It is recommended that users read this chapter systematically and follow the instructions
to have a basic understanding of the ELCO Spider67 Mobile product. At the same time,
ELCO will continue to improve and explain specific functional details, please refer to the
subsequent version updates.
If you encounter problems during use, you can submit them to our Customer Support
Center or send an email to the IoT question mailbox: [email protected]
For product related information, you can go to the official website to download the
corresponding product manual:
ELCO website: http://www.elco-holding.com.cn
ELCO Spider67 Mobile platform website: http://spider67.elcocloud.com
1.1 Hardware environment
The standard application architecture of the Spider67 Mobile is as follows:
Hardware (standard application):
- Servers running the IoTHub system and the Spider67 Mobile application management
platform (cloud deployment version, local server version), and related software and
network support resources;
- One computer for configuration operation: used for login configuration platform, WiFi
related version configuration requires Android or iOS mobile terminal, the specific
requirements refer to Bluetooth configuration tool App related requirements;
-
2
- Spider67 Mobile related hardware 1 set (standard sales package only includes gateway,
various antennas, 2m M12 single-ended pre-wired plug-in power cord), if expanded I/O
and supporting connection components needed, please purchase them separately;
- The WiFi version gateway needs to be equipped with a WiFi router (AP hotspot)
according to the network working mode;
- The LTE version needs to prepare a SIM card (the SIM card is not standard, the specific
specifications refer to the relevant description);
Wiring:
- Connect extended I/O components according to requirements (optional parts, refer to
relevant selection manual and operation instructions);
- Connect the sensor or output point of the relevant I/O point according to actual needs;
Networking:
- For LTE version gateway, insert the SIM card in the power off state (refer to the relevant
instructions for use);
- For WiFi version gateway, complete the related operations through the supporting
Bluetooth configuration tool App after power-on;
Power:
- Spider67 Mobile series gateway products are equipped with M12 A-Code male
connector to connect to the gateway power interface. The power supply part refers to the
detailed requirements and selects qualified power supply to ensure the stability of network
connection and I/O transmission.
Status indicator:
- According to different versions of the gateway configuration, PWR lights, WiFi lights,
module lights, LTE lights, and I/O lights are all green to indicate normal operation (refer to
the relevant instructions for details).
1.2 Network environment
The configuration and data transmission of the Spider67 Mobile series gateways need
network environment support. The LTE version gateway needs to use the relevant LTE
network.
-
3
Remark:
SPMB-16DIO normal products sold in China supports the LTE network of China Mobile,
China Unicom and China Telecom . Through the installation of the relevant operator's SIM
/ IoT card, it achieves network connectivity and data transmission.
SPMB-16DIO -EU series products sold in Euro need confirm with ELCO Germany to get
support from network partner.
According to the configuration of the gateway, the WiFi version requires the local WiFi
router to provide the AP, or for the LTE+WiFi version, WiFi can be used as the AP to
connect related WiFi gateway module (04AIO product).
2 Product descriptionThe Spider67 Mobile IoT I/O products, including digital, analog gateways and expansion
I/O, come standard with the IoTHub user application platform. The system is independent
of PLC and related control systems, and has the capability of intelligent IoT control node
with autonomous acquisition and uploading and logic control.
-
4
Spider67 Mobile gateway products support sensor formula customization and I/O logic
control capabilities, which can realize basic I/O channel definition and configuration, I/O
logic definition and configuration, digital and analog signal acquisition and upload, and
local support edge Logic processing capability, threshold judgment and output and
intervention control, wherein the input support extension can connect water (liquid) level
meter, temperature and humidity sensor, various gas detection sensors, pressure,
vibration, current and voltage, etc., support 0- 5V, 0-10V, 0-20mA, 4-20mA multiple
channel types are selected for industrial temperature and humidity monitoring, heat
network monitoring, gas monitoring, equipment testing, environmental testing,
meteorological testing, modern agricultural control and other industrial applications.
2.1 Product features
Standard M12 circular connector wiring, up to IP67 protection
LTE, WiFi version is optional, to meet the data transmission needs of different
application
Support Bluetooth configuration, standard configuration App tool, user-friendly
operation (WiFi version)
Multiple analog specifications, single gateway or I/O modules can be customized
within the scope
-
5
Analog support 16-bit resolution, current acquisition accuracy ±0.2% FSR, voltage
acquisition accuracy ±0.1% FSR
Support prefabricated patch Io card to meet various working conditions and security
protection requirements (LTE related version)
Secure Transmission Layer Protocol (TLS) encryption to ensure security and integrity
in data transmission
Standard ELCO IoTHub platform connection protocol to support third-party protocol
extension and application development
Standard application management platform to support customized application
platform development or API interface service
2.2 Product model
Item Product model Spider67 Mobile hardware description
1 SPMB-16DIO-001 Digital (16-way) extensible gateway, LTE version
2 SPMB-16DIO-002 Digital (16-way) extensible gateway, WiFi version
3 SPMB-16DIO-003 Digital (16-way) extensible gateway, LTE+WiFi version
4 SPMB-04AIO-012 Current analog input (4-way) gateway, WiFi version
5 SPMB-04AIO-022 Voltage analog input (4-way) gateway, WiFi version
Model Description
-- SPMB-16DIO-001, SPMB-16DIO-003 products all support LTE communication version
products. The matched LTE modules support standard Micro-SIM, SMD Io card. The user
can provide its IoT SIM card to ELCO for factory pre-installed service, and the default
factory related products do not include the data flow charge.
-- SPMB series support product of WiFi communication version, provide WiFi module
(2.4GHz). Users can apply the configuration tool App to complete the basic WiFi function
and server function configuration;
-- All products are connected to ELCO IoTHub platform by default. Based on the Spider67
protocol and CB200 protocol, some products can be integrated with TCP/IP, UDP, DHCP,
-
6
HTTP, Modbus/TCP, etc. according to user requirements. For details, refer to the technical
support description of the actual gateway product;
-- SPMB-16DIO series gateway product only supports digital input and output interface,
you can define I/O type through configuration platform. For analog input and output
products, you need to select expansion I/O components, and perform I/O capability
expansion and configuration applications according to relevant rules;
-- SPMB-04AIO series gateway products support current analog and voltage analog
inputs. Specific requirements are selected with reference to the relevant models. This
series does not support I/O expansion capabilities;
-- Digital I/O gateway and I/O module product only support PNP type for sensors
connection. Analog gateway and I/O module products support ±20mA, ±10V, 0~20mA,
4~20mA, 0~5V, 0~10V. Related products refer to the specific selection manual. For
analog sensor conversion, refer to the application management platform custom formula
function;
-
7
3 Basic hardware parameters
3.1 SPMB-16DIO data sheet
Spider67 Mobile SPMB-16DIO series hardware only provide 16-way digital input or output
I/O connect ports for sensors or actuators.
Input voltage Nominal voltage 24VDC(10 ~ 30VDC) (+/- 10%)
Output voltage
Output voltage 24VDC(10 ~ 30VDC) (+/- 10%)
Output current 2A per channel (max. 2.5A per channel)
Short circuit current 20mA@ per channel
Switch outputOutput voltage Output voltage -0.7V
Output type PNP
Digital input
Logic low/high level voltage 0V~1.2V / 3.5V~30V
Input Current 6.4mA (@24VDV input)
Short circuit current Continuous 200mA (pulse 400mA)
Output type PNP
Matching sensor PNP 3-wire、PNP 4-wire、PNP 2-wire
LTE module
LTE-FDD, LTE-TDD, UMTS/HSPA+, GSM/GPRS
Built-in SIM card
Support external antennas to improve signal quality
GSM/GPRS power level EGSM900(2W), DCS1800(1W)
EDGE power level EGSM900(0.5W), DCS1800(0.4W)
UMTS power level WCDMA(0.25W)
LTE power level 0.25W
WiFi module
safety WEP, WPA-PSK, WPA2-PSK
Spectrum range 2412MHz-2484MHz
Transmit power
802.11b:16±2dBm(@11Mbps)
802.11g:14±2dBm(@54Mbps)
802.11n:13±2dBm(@HT20,MCS7s)
-
8
Maximum distance* 100 meters (open and unobstructed)
Bluetooth
module
Spectrum range 2402MHz-2480MHz
Transmit power -20dBm~4dBm
Maximum distance* 10 meters (open and unobstructed)
Working temperature / humidity -25℃ ~ +70℃/0~95% RH without condensation
Storage temperature / humidity -25℃ ~ +90℃/0~95% RH without condensation
Protection level IP67(**)
Anti-vibration level Compliance with IE68-2-6
Remarks:
*: The supporting module supports multi-mode system, and the actual application needs
to be combined with the operator network!
**: The back cover of the gateway supports opening and installing the IoT card, and the
sealing effect will affect the protection level!
3.2 SPMB-04AIO data sheet
Spider67 Mobile SPMB-04AIO series hardware only provide 4-way digital input I/O
connect ports for sensors.
Input voltage Nominal voltage 24VDC(10 ~ 30VDC) (±10%)
Analog input
±20mA、±10V、0~20mA、4~20mA、0~5V、0~10V
Current signal ±0.2% FSR
Resolution 16 bits
Impedance 120Ω
Voltage signal ±0.1% FSR
Impedance 1KΩ
WiFi module
WLAN IEEE 802.11b/g/n 2.4GHz
safety WEP,WPA-PSK,WPA2-PSK
Spectrum range 2412MHz-2484MHz
Transmit power802.11b:16±2dBm(@11Mbps)
802.11g:14±2dBm(@54Mbps)
-
9
802.11n:13±2dBm(@HT20,MCS7s)
Max. distance* 100 meters (open and unobstructed)
Network protocolIoTHub platform Spider67 protocol,CB200 protocol
Standard agreement TCP/IP, UDP, DHCP, HTTP, Modbus/TCP
Bluetooth
module
Spectrum range 2402MHz-2480MHz
Transmit power -20dBm~4dBm
Maximum distance* 10 meters (open and unobstructed)
Operating temperature -25℃ ~ +70℃/0~95% RH no condensation
storage temperature -35℃ ~ +85℃0~95% RHno condensation
Protection level IP67(**)
Anti-vibration level Compliance with IE68-2-6
Remarks:
*: The max. communication distance is combined with the actual scene test!
**: The interface needs to be sealed with a sealing cover!
-
10
4 Hardware interface description
4.1 SPMB-16DIO function port description
4.1.1 SPMB-16DIO gateway
4.1.2 SPMB-16DIO I/O port description
The SPMB-16DIO is equipped with 8 ports (P0~P7) for a total of 16-way digital
transmission channels. 16-way I/O channel type configurations (in the digital range) can
be completed through the application management platform and configuration tools,
including a variety of typical I/O modes, as follows:
- 16DIO mode, input or output for user-defined application mode
- 16DI mode, 16-way digital input application mode
- 16DO mode, 16-way digital output application mode
-
11
- 8DI+8DO mode, 8-way input + 8-way output application mode
- Free configuration mode ( refer to ELCO configuration file definition rules)
4.1.3 SPMB-16DIO LED indicator description
SPMB-16DIO has multi-channel LED indicator light, which is convenient for users to
observe and judge the working status of the equipment, and quickly complete the
diagnostic analysis of the equipment.
(Note: SPMB-16DIO series is the same)
Symbol Function definitionStatusindicator
Indicator color description
PWR PowerGreen NormalRed Abnormal
WiFi module signal
Red The Device wireless connection is failedOrange The device is not connected using WIFI
GreenThe device uses WIFI connection and
the connection is normal.
MODModule status Red Working failure
Green Working normally
LTE module signal
Red The Device wireless connection is failed
OrangeThe device does not use LTE connection
or the signal strength is weak
GreenThe device uses LTE connection and has
good signal strength
Link Extended I/O statusRed
No expansion I/O module or extendedI/O module abnormal
GreenExtended external I/O modulecommunication is normal
Remark:
Please make sure that the device is powered on, LTE test need the SIM card is installed
correctly, or WiFi network is connected, or extended I/O module is connected correctly,
some environments need to wait 2-3 minutes after the device is powered on.
-
12
Symbol Function definitionStatusindicator
Indicator color description
B&AP0-P7
I/O channel statusGreen High input or outputNo color Low input or outputRed Short circuit or overload
Remark:
The I/O status requires correct sensor connect, including power supply and signal lines.
Detail sensor connect please review the section “4.1.5 SPMB-16DIO I/O channel
description”
4.1.4 SPMB-16DIO module description
In order to facilitate platform configuration management and protocol definition, the
module of Spider67 Mobile in IoTHub standard communication protocol is defined as 0~X
(Remark: This X not a fixed value for all application mode, the value depends on the
number of final expansion modules, and the relevant regulations refer to ELCO final
technical specifications and update instructions. Currently Gateway could extend
max 6 expansion I/O modules, so the X value max is 8).
On the application platform the Gateway configuration page need user know how to define
the module, the channel marked is “M*_P*A”, refer to the figure below is “M0_P0 A”
-
13
The maximum port based on the extension module is 4 ports. In order to facilitate
configuration management, the IoTHub system defines each group of 4 I/O ports as a
module by default, so the SPMB-16DIO series gateways P0~P3 ports are defined as
Module_0, P4~P7 ports is defined as Module_1 (refer to the following figure). The
subsequent extended I/O modules are sequentially numbered as Module_2, Module_3,
and so on.
4.1.5 SPMB-16DIO I/O channel description
Each signal channel acts as a separate channel for digital signal input or control signal
output. The IoTHub standard communication protocol is based on the coding rules from 0
to X (the X value depends on the number of final expansion modules. Relevant
regulations refer to ELCO final technical specifications and update instructions.). P0 portA
channel is defined as Channel_0, P0 portB channel is defined as Channel_1. Combined
with the module information is defined as module_0_channel_0. The rest can be done in
the same manner.
The SPMB-16DIO gateway I/O port is of standard M12 A Code connector. The associated
Pins are defined as follows:
-
14
I/O port pin definitionInformation indication
No. Function1 +24VDC2 A signal input ▲A indicator3 GND4 B signal input ▲B indicator5 PE
4.1.6 SPMB-16DIO power supply interface description
The SPMB-16DIO gateway power supply interface is M12 A-Code male interface, which
uses the ELCO connection system standard A-Code connector product, or A-Code field
wiring connector to connect the power supply.
Remark: The power supply requirements of the equipment refer to the equipment
requirements. Unqualified power supply may affect the equipment use or cause
equipment damage! !
M12 A-Code male interface
Note: The PIN indication map needs to be rotated counterclockwise by 180 ° to
correspond to the gateway installation diagram.
Power supply interface pin definitionInformation indication1 Module and output
+24VDC2 Module and output
+24VDC——
3 Module and output GND ——4 Module and output GND ——5 PE ——
-
15
4.1.7 SPMB-16DIO I/O module expansion instructions
SPMB-16DIO supports I/O extension function, and realizes IoT I/O expansion application
by using ELCO connection system component and Spider67 I/O expansion module
product through module expansion interface (M12 B-Code). The current version of the
gateway supports up to 4 I/O modules. The subsequent version upgrades refer to the
ELCO upgrade standard.
M12 B-Code female interface
Note: The PIN indicator map needs to be rotated 135 ° clockwise to correspond to the
gateway installation diagram.
Power supply interface pin definitionInformation indication
1 Reserved2 485 _BUS_A Not open3 GND4 485 _BUS_A Not open5 PORT_MAC_SET
4.1.8 SPMB-16DIO SIM card operating instructions
SPMB-16DIO supports LTE versions, the related product network connection requires the
communication operator’s SIM card or the IoT card support, and the data traffic function is
enabled.
Remark: the description applies to Rev 1.1, Rev 1.2 hardware products!
Gateway communication board expansion SIM operation steps:
1) The gateway is powered off; open the protective back cover at the bottom of the
gateway, as shown in the following figure, you can see the SIM card slot. The standard
card slot is a flip-type slot.
-
16
2) The user needs to follow the correct SIM card placement operation to ensure that the
SIM card is in good contact.
3) After the card is inserted, install the protective back cover to ensure that the gateway
housing meets the factory setting requirements. The assembly process ensures that this
operation does not affect the connection of the associated antenna to ensure the
effectiveness of communications.
-
17
Remarks: Due to the SIM card replacement, if you need a higher degree of protection, you
can use the glass glue to seal the bottom cover yourself, or choose the ELCO built-in chip
SIM card solution.
The gateway communication board reserved SIM card specification is a Micro-SIM card.
Its dimensions are as shown below. The operator's choice needs to comply with the
supporting LTE module support network type, such as the user's bulk order can accept
IoT card pre-assembly service.
-
18
The communication expansion board supports the SIM card/IoT card. For example, the
user’s bulk order can use the IoT card pre-installed service, and the SIM card version
supports the back cover potting service (in combination with the ELCO update
specification) to meet the higher level of protection needs.
The Chip SIM card / IoT card reference specification dimensions as shown below:
Remark: the chip SIM card not the e-SIM support Over the Air defined in China
-
19
4.2 SPMB-04AIO function interface description
4.2.1 SPMB-04AIO series gateway
SPMB-04AIO products are equipped with 4 ports. I/O channel type configuration (in
analog range) can be accomplished through application management platform and
configuration tools, including a variety of typical I/O modes, as follows:
—— 4-channel current analog input mode
—— 4-channel voltage analog input mode
Note: The final delivery model is based on the ELCO CRM system or product manual!
4.2.2 SPMB-04AIO series LED indicator description
SPMB-04AIO products set multi-channel LED indicator light, which is convenient for users
to observe and judge the working status of the device, and quickly complete the diagnosis
and analysis of device.
-
20
Symbol Functiondefinition Indicatingstatus
Indicator color description
PWR Power indicationGreen Normal workRed Abnormal
WiFi module signalindication
RedThe device wireless connection is
unsuccessful
OrangeThe device does not use WIFI
connection
GreenThe device uses WIFI connection and
the connection is normal
MODModule statusindication
Red The device itself is malfunctioningGreen The device itself is working normally
LinkExtended I/O status
indication
RedNo extended I/O module or extended I/O
module abnormal
GreenExtended external I/O modulecommunication is normal
Symbol Functiondefinition Indicatingstatus
Indicator color description
P0-P3I/O channel status
indication
Green Normal signalRed Abnormal signal
Colorless No signal
The I/O status requires correct sensor connect, including power supply and signal lines.
Detail sensor connect please review the section “4.2.4 SPMB-04AIO series I/O channel
description”
-
21
4.2.3 SPMB-04AIO series I/O Module description
In order to facilitate platform configuration management and protocol definition, the
module of the Spider67 Mobile series in the IoTHub standard communication protocol is
defined as 0~X (the value of X depends on the number of final extended modules, and the
relevant regulations refer to the final technical specifications and update instructions of
ELCO). Based on the maximum port of the extended module is 4 ports, for ease of
configuration management, the IoTHub system defines each group of 4 I/O ports as a
Module by default, so the SPMB-4AIO series gateway main body P0~P3 ports are defined
as Module_0.
4.2.4 SPMB-04AIO series I/O Channel description
Each signal channel acts as a separate Channel for digital signal input or control signal
output. In IoTHub standard communication protocol, according to the encoding rules it
adds from 0 to X (the value of X depends on the number of final extended modules, and
the relevant regulations refer to the final technical specifications and update instructions of
ELCO).P0 port A channel is defined as Channel_0, P0 port B channel is defined as
Channel_1.Combining with the module information it is defined as module_0_channel_0,
subsequent numbers and so on..
The SPMB-04AIO gateway I/O port is in a standard M12 A Code connector. The relevant
Pins are defined as follows:
-
22
I/O port pin definitionInformation indication
No. Function1 DC24V+ ——2 AI/AO+ ——3 DC24V- ——4 AI/AO- ——5 Shield ground PE ——
4.2.5 SPMB-04AIO series power supply interface description
The power supply interface of SPMB-04AIO series gateway product is M12 A-Code male
interface, which uses ELCO connection system standard A-Code connector product, or
A-Code field wiring connector to connect the power supply.
Note: The power supply requirements of the device refer to the device requirements.
Unqualified power supply may affect the use of the device or cause device damage!!
Detailed explanation of M12 A-Code Male interface
Note: The PIN indication map needs to be rotated counterclockwise by 180 ° to
correspond to the gateway installation diagram.
Power supply interface pin definitionInformation indication
No. Function1 Module and Output +
24VDC——
2 Module and Output +24VDC
——
3 Module and Output GND ——4 Module and Output GND ——5 PE ——
-
23
4.3 SPMB series of WiFi configuration operation description
Some SPMB-16DIO products and 04AIO products all support WiFi network.The related
products WiFi network working mode and configuration mode are different.You need to
complete the relevant settings based on the Bluetooth configuration tool App.
The WiFi function of SPMB-16DIO product supports AP and AP Client working modes. AP
mode supports gateway extended connection of 0~7 AP Client, including SPMB-16DIO,
04AIO gateway products, and third-party WiFi terminal products(gateway, sensor)for
related adaptation work. Related configuration can be configured through the Bluetooth
configuration tool App which provided by the ELCO.
The WiFi function of SPMB-04AIO product only supports AP Client working mode.
Related configuration can be configured through the Bluetooth configuration tool App
which provided by the ELCO. The specific operations are as follows:
Four operation steps: adding device, selecting device, configuring device and configuring
delivery.
-
24
-
25
4.4 Product Dimensions
4.4.1 SPMB-16DIO series
4.4.2 SPMB-04AIO series
-
26
5 Management platform operation descriptionThe current platform operation is only for the SPMB-16DIO series products, and the
04AIO products are not yet adapted. Subsequently, ELCO will update the relevant
platform functions and operation descriptions according to the product delivery schedule.
The final interpretation right belongs to ELCO.
5.1 User Login
User login interface
Users enter the provided management platform address through the IE browser and use
the relevant username/password to complete the user login. Different browsers support
different platform systems, including the reality of the interface of the reality and the
storage of login information, etc., ELCO recommends to use Google Chrome or other
browser products that support the Chrome kernel in order to get the best user experience.
The reference interface is as follows.
Note: Different browsers and operating systems may store or record login information!
Note:
Please contact the relevant customer manager for the relevant username and password.
If the user has purchased a customized deployment management platform, the login
address and login information refer to the delivery manual.
-
27
Currently platform is v1.1, if the version upgrades,the login information and interface may
change, and the final interpretation right belongs to ELCO.
5.2 Group management function description
If the user login for the first time as an administrator account, group management and user
management shall be carried out according to the actual usage requirements, so as to
facilitate the specific application management of the subsequent platform.
The platform supports user group management, which facilitates the assignment and
usage management of subsequent terminals. You can create a group by creating a new
group, or modify the group name by modifying button, or delete the group.
-
28
5.3 User management
Authorized users are the subject of subsequent operations. Based on group management,
new user and management of authorized should be completed in advance.
The system default administrator can add users, and the related operations can be
enabled by buttons. This function requires administrator privileges to perform related
operations.
Remark: Administrator account please contact ELCO company.
: This function is to change the password operation, which is convenient for users to
modify the initialization password and enhance the security of use.
: Edit user information
: Delete user information
Refer to the following configuration for adding users and configuring user interface. After
editing, you need to confirm the validation.
New user operation:
-
29
Modify operation process for user information, administrator account could modify their
own and any user account, select the account and click the edit button to do the process,
and click “Ok” to complete.
Administrator account could delete any user account, select the account and click the
delete button to do the process, and click “Yes” to complete, platform will get a success
message.
This operation is performed related configuration management by administrator, and the
administrator account needs to be contacted with the ELCO customer manager for
confirmation.
-
30
5.4 Introduction of the basic functions of the platform
5.4.1 Page layout description
Specific page operation information refers to the specific menu content.
Note: The standard version of the platform UI will be optimized based on user’s feedback
and platform upgrades. The final interpretation right belongs to ELCO.
The layout on the left side of the page is the platform
"Menu Bar", and the menu bar can be minimized by the
" " button on the right side. The rightmost side is the
user login operation information and alarm information.
The reality content of the main page is Dashboard.
Users can add relevant key information reality as
required, logging in, and directly view the related
information.
-
31
Users can choose basic Settings and platform language through relevant menus listed
below, include review the version information, change password, logout, or change
language within Chinese\English\Deutsch.
5.4.2 Device management function description
Users can add related devices by themselves through the “Add” button on the right side of
the device management page. The "Listening Device" button reserves the function for the
system and does not provide application logic now.
Users add devices by inputting the IMEI number of product shell, and the device
confirmation is completed by the right query button.
Note: Before the device is entered, you need to ensure that the device is connected to the
network (insert SIM card or connect to WiFi), and ensure that the device is powered on.
Click the “ ” button user could add a new device by themselves.
-
32
This process need confirm the IMEI is correct for the new device, if there is an error, the
system will prompt you for the possibility.
By querying, if the device has registered and bound in IoTHub system, a green correct
prompt icon appears on the right side of the added page, and the information addition
page is automatically entered. You can view the device ID (Device ID is automatic
allocation by IoTHub), customize"Device Name", and "Group"allocation options, and
make sure to add the device.
-
33
“ ” button is used to unbind the operation. Through this operation, the binding
relationship between the terminal and the platform can be released. The unbind terminal
can be added to the platform again.
5.4.3 Configuration for gateway
After the device is added, user could review the Signal strength & the Signal symbol for
device, and could perform related configuration, logical association, and unbinding
operations on the device through the buttons in the “Operation” menu.
Click the “ ” device configuration button, through which you enter the device
configuration page. Based on the actual requirements and Spider67 Mobile hardware of
the user side, the related configuration functions of SPMB-16DIO gateway and extended
I/O device can be completed in the next process.
-
34
The 16DIO product page displays the configuration graphical interface of 2 channels by
default. The default channel configuration configuration can be selected through the
graphical interface. The operation steps are as follows:
Through the Port selection of the gateway body, the outer circle of the corresponding Port
of the page turns green, and the channel information on the right side displays the current
information.
Enter the relevant information configuration page, including Label, I/O type definition
(input or output), signal type definition, High or Low threshold, formula (for calculating of
sensor collection value and display value, specific reference sensor manufacturer
formula), linkage configuration.
-
35
Remark: After the support linkage is selected, the subsequent linkage configuration
function can be completed. The SPMB-16DIO series standard gateway configuration port
only for digital Channel. For analog collection requirements, the analog extended I/O
module product needs to be purchased separately.
-
36
After the gateway configuration process, the port & the channel turn color from black to
green to show the configuration is completed, use could select “Cache configuration” if the
configuration still not completed, or “Delivery configuration” to complete this configuration.
5.4.4 Configuration for I/O device
Extended I/O device operation,through the right " " button to complete the module type
selection and addition operation.The main type of extended module is analog, which
covers current analog, voltage analog input and output module, and then gradually
perfecting and enriching.
-
37
After selecting the module type, the page displays the extended I/O device graphical
configuration page, through the Port selection of the I/O body, the outer circle of the
corresponding Port of the page turns green, and the channel information on the right side
displays the current information. The specific configuration can be specifically configured
through the “ " button in the upper right corner of the channel frame. Channel title, I/O
definition (input or output), signal definition, formula (for calculating of sensor collection
value and display value, specific reference sensor manufacturer formula), linkage
configuration.
-
38
After the gateway configuration process, the port & the channel turn color from black to
green to show the configuration is completed, use could select “Cache configuration” if the
configuration still not completed or add other I/O device again, or “Delivery configuration”
to complete this configuration.
After entering the “Configuration” page, the gateway still need some process to work, user
need to configure the gateway, including setting list below:
“Reporting Interval”: adjusting the time through subsequent -/+ operations, the unit of time
is second.
“←”: return button, return the page of device list.
“ ” : view the full Spider67 Mobile system configuration
“Cache configuration”: cache all configuration temporary.
"Delivery configuration" : configuration delivery to the target device.
-
39
5.4.5 Cloud logic control function description
Based on the application platform, Spider67 Mobile hardware provide cloud-based logical
control capability for users, who can complete the logical association configuration for the
I/O of devices at the platform side, so as to complete the relevant simple logical control
requirements.
Remark: The current version of logic is based on cloud computing processing, and the
use process needs to ensure that the 4G or WiFi network connection is normal so that
logical instructions can be executed.
Associated operation supports the user to complete the I/O logical association
operation by dragging and dropping logic. This operation needs to set the support linkage
in the process of configuring the I/O Channel.
-
40
The input channel and output channel for Channel configuration linkage will appear in the
associated page. The above is the input channel signal source list and the below is the
output channel.
Click the “Linking Title” to modify the linkage name follow the logic demand.
Analog logic could define threshold to modify the Digital output, or Digital logic within two
digital channel, the logic input could include analog and digital channel, but output only for
digital channel.
-
41
5.5 Dashboard function description
The content of the Dashboard can visually display the status of the key data that the user
is concerned with.And the user can add relevant display content and set relevant alarm
thresholds by himself. The user adds and configures the new Dashboard through the right
" " button.
Dashboard graphics can be dragged, adjusted, paused, and deleted by the mouse!
Enter the Dashboard new page to do the relevant configurations, the process include
three step to get a new dashboard, the first step including the selection of “Device Name”,
gateway “imei”, “Data association” and preview, after confirm could click next button
continue process.
The second step could rename the “Chart title”, select “Formula” about the sensor connect
on the I/O port, after preview could click next button continue process.
-
42
The third step could select the “Chart type” and colors, after preview could click the “Insert
Chart” button completed the new dashboard.
-
43
Remark:
The current version platform "Display Icon Title" is automatically added by the system.
When "Data Association" is selected, the system automatically adds the title content, and
the subsequent versions gradually expand the user-defined solutions.
The icon type temporarily only provides a line chart solution, and subsequent UI gradually
upgrades to expand other types.
After the “Device” is selected, the system automatically displays the device "IMEI" number,
and the user can check whether the corresponding deivce information is correct or not
according to the files.
Data association is used to select a specific I/O channel (sensor) data source, which is
convenient for displaying user's attention data.
Polling frequency is the time interval of refreshing data per second for system.
High and low thresholds display the alarm data values, and the high and low threshold
alarm lines can be generated in the Dashboard. It is convenient for users to view and
compare data collection and display.
The color is used to define the display color of the curve.
Note: The X axis of the Dashboard display interface is the time axis, and the Y axis is the
automatic segmentation of the display accuracy. Combined with the sensor type, the
real-time collection value and data conversion formula calculation to realize automatic
change.
-
44
5.6 Alarm log function description
The current version of the UI alarm log is displayed in the form of a list, showing the
device name, Device Id, label name, device channel, alarm value, and alarm time
respectively.
Device Id is the unique ID number of the device automatically assigned by IoTHub. The
device channel corresponds to the description of relevant I/O interface. The alarm log
supports the " " function.
5.7 Device binding function description
The device binding function supports the administrator/user to complete device
assignment and user binding within the scope of authority. The user can select the group
-
45
and user name to perform the device assignment and binding operations, and confirm the
configuration after completing the relevant configuration.
The device bound by the end user can be directly associated with the user name, and
other users except the administrator cannot view it.
5.8 Customize formula function description
As an acquisition and transmission system of IoT, Spider67 Mobile system needs to
convert the measured values of sensors into analog-to-digital ones so as to complete data
transmission through the network, and the platform converts the data into the measured
values of sensors.
So, the platform supports user-defined conversion formulas for sensor measurement
values and application values, so that users can customize the conversion with different
brands and types of selected sensors to facilitate data application display (Dashboard
function).
Remark: This function is applicable to the conversion of analog sensor. Please refer to the
sensor manufacturer's manual for the specific conversion method.
Note: The specific calculation formula refers to the sensor user manual, the small letter “x”
represents the collection value by the Spider67 Mobile system, and the user completes
-
46
the definition of the formula based on this value (only supports addition, subtraction,
multiplication and division), and unit definition.
For example: a temperature sensor, user can modify the “Formula name”, “Conversion
formula”, “Display unit” and “Remarks”, and the key point is the “Conversion formula”.
-
47
6 FOTASpider67 Mobile series hardware support FOTA functions.
To Be Supplemented!!
7 Appendix
7.1 Glossary
To Be Supplemented!!
7.2 Legal notes