EIGERFLEX ® -Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data) 4.110 EIGERFLEX ® -Clima pipe DN 20-110, Carrier pipe ø 25-125 mm 4.2 Planning, design engineering 4.200 Pressure loss 4.205 Heat losses 4.3 Components 4.300 Connection 4.310 Insulating material 4.320 Pipe Fittings / Screwed, welded 4.330 End cap 4.340 Wall sealing ring / Pipe warning tape 4.345 Wall duct / Core drilling 4.5 Underground construction work, assembly 4.500 Trench dimensions Pipe entry into buildings Openings in walls

Upload: others

Post on 01-Apr-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Description

CPE

4.0

05.02.2006

4.0 Table of contents

4.1 System description

4.100 System description (data) 4.110 EIGERFLEX®-Clima pipe DN 20-110, Carrier pipe ø 25-125 mm

4.2 Planning, design engineering

4.200 Pressure loss4.205 Heat losses

4.3 Components

4.300 Connection4.310 Insulating material4.320 Pipe Fittings / Screwed, welded4.330 End cap4.340 Wall sealing ring / Pipe warning tape4.345 Wall duct / Core drilling

4.5 Underground construction work, assembly

4.500 Trench dimensionsPipe entry into buildingsOpenings in walls

Page 2: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

System descriptionflexible district cooling pipe system

CPE

4.100

05.02.2006

1. Medium pipe

Material: Polyethylene (HDPE) class SDR11, acc. to DIN EN ISO 12162Life expectancy: 50 years at 20°C and 16 bar continuous load (acc. DIN 8074) Characteristics: Suitable for cold water and sewage/waste water pipes operating up

to 30 °C and 13.5 bar

3. Heat insulation

Material: - EIGERFLEX® - potable water:CFC-free, 100% CO2 -blown polyurethane foam (PUR)

- EIGERFLEX® - cooling:CFC-free, cyclopentan-blown polyurethane-foam (PUR)

PE medium pipe

DensityHeat conductivityUltimate tensile strength (tearing resistance)Modulus of elasticityLinear expansion coefficientCrystallite melting range

Ref.temperature °C

––

202020–

Value

0,952-0,9600.43>19

10001.8 · 10 E-4

130-135

g/cm3

W/mKN/mm3

N/mm3

1/K°C

Test standard

DIN 53479DIN 52612DIN 53455DIN 53457DIN 52328

PUR-insulation

DensityThermal conductivity: Co2-foam Thermal conductivity: Pentane-foamClosed cellular structureWater absorption after 24 hrs.

Ref.temperature °C

–3030––

Value

> 60 ≤ 0.029≤ 0.022

≥ 90≤ 10

kg/m3

W/mKW/mK%%

Test standard

DIN 53420DIN 52612DIN 52612

–EN 253

4. Casing

Material: Polyethylene of low density, PE-LD, extruded seamlessPurpose: Protection against mechanical damages and moisture

PE-LD-protective casing

DensityHeat conductivity Crystallite melting range

Ref. temperature °C

–––

Value

928-9380.43

105-110

kg/m3

W/mK°C

Test standard

DIN 53479DIN 52612

Page 3: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Product range25 - 125 mm

CPE

4.110

05.02.2006

PE-foil PE-LD casing, corrugated

PUR-foamPE Medium pipe

UNO

s1s

d D

EIGERFLEX®-Clima pipe

Type DN Inches

[“]

Medium pipe PE

d x s

mm

Outher casing

D x s1

mm

Min. bendingradius

m

Medium

pipe

volume

Weight

kg/m

max. delivery length

Jumbo-Coil Maxi-Coil

m m

25/7632/7640/9150/9163/12675/12690/162110/162125/182

20253240506580

100110

3/4"1"11/4"11/2"2"21/2"3"4"41/2”

25 x 2.332 x 2.940 x 3.750 x 4.663 x 5.875 x 6.890 x 8.2

110 x 10.0125 x 11.4

78 x 2.078 x 2.093 x 2.293 x 2.2128 x 2.7128 x 2.7163 x 3.2163 x 3.2183 x 3.3

0.70.70.80.81.01.01.21.21.5

0.3270.5390.8351.3072.0912.9614.2546.3628.199

0.901.001.391.542.602.754.565.696.97

76076056056028028014414486

• Further insulation thickness classes on request (quantity > 500 m) • Larger lengths can be supplied on request.

Ring dimensions: Jumbo Coil outer diameter 2800 mm x 800 mm (width)Maxi Coil outer diameter 2800 mm x 1200 mm (width)Seafreight Coil fitted for open top seafreight containers or 40 ft

high cube containers

5205203773771921929292-

Page 4: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Pressure lossPE pipe, flow diagramm

CPE

4.200

05.02.2006

Water, average temperature 20 °C

Roughness ε = 0.01 mm (PEHD)(1 mmWS = 9.81 Pa)

Pressure loss ∆p [Pa/m]

Water speed

Flo

win

m[k

g/h

]

1000

010

0030

050

020

0030

0050

0020

000

3000

0

10020 20050

1000

200050

0

32/26.2

(DN 25)

40/32.6

(DN 32)

50/40.8

(DN 40)

63/51.4

(DN 50)

75/61.4

(DN 65)

30 40 300

4000

0

1600

1200

1800

1400

4000

2.0m

/s1.5m

/s1.0m

/s

0.4m

/s

0.75m

/s0.5m

/s

3.0m

/s

120

180

140

160

80 800

0.3m

/s

90/73.6

(DN 80)110/90

(DN 100)

400

25/20.4

(DN 20)

125/102.2

(DN 110)

Page 5: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Heat lossesunder ground/above ground

CPE

4.205

05.02.2006

21 3 4 5

40/91 63/12675/126

90/162

Ch

ille

dw

ate

r,T

m°C

15°

10°

Heat loss, q W/m W/m1.5 2.5 3.5 4.5 5.5 6

25/76

50/91

110/162 125/182

0.140

0.189 0.2260.210

0.272

0.245

0.412 0.420

Dimensions

0 0.5

32/760.178

U- Value (W/mK)

415° 10° 5° 1°

2 6 8 10

75/1

26

Chilled water, Tm °C

40°

35°

30°

Air temperature, Ta °C

25°

Heat loss, q (W/m) W/m3 5 7 9 11 12

20°

0.301

Dim

ensions

36°

U- Valu

e (W/m

K)

25/7

6

0.143

32/7

6

0.184

40/9

1

0.195

63/1

260.2

32

50/9

1

0.257

90/1

620.2

75

110/

162

0.420

125/

182

0.421

1. Laying under ground

2. Laying above ground

Heat transfer coefficient: a = 14 W/m2KAmbient conditions: wind strength, Scale Beaufort 1, velocity 0.3-1.5 m/s

Average earth temperature: TE = 15°CConductivity of ground: λ = 0.5 W/mK

Page 6: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

ConnectionJoint sleeve, GFK-shell

CPE

4.300

05.02.2006

Joint sleeved1 d2

1 2 3 4

EIGERFLEX

Fitting the T-piece

3 2 4 51

d1 d3

d2

645 mm

max

.490

mm

1 PE joint, see sheet CPE 4.3202 Insulation material, see sheet CPE 4.3103 Shrinkdown sleeve pipe4 Shrinkdown tube

all Ø dimensions in mm

d27691

126162182

76xxx

91

xx

126

xx

162

xx

d1

182

x

Ø d1 Ø d325/76-25/7632/76-32/7640/91-40/9140/91-32/7650/91-50/9150/91-40/9163/126-63/12663/126-50/9175/126-75/12675/126-63/12690/162-90/16290/162-75/126110/162-110/162110/162- 90/162125/182-125/182125/182-110/162

25/76xxxxxxxxxxxxxxxx

32/76

xxxxxxxxxxxxxxx

40/91

x

xxxxxxxxxxxx

50/91

xxxxxxxxxxxx

63/126

x

xxxxxxxx

75/126

x

xxxxxx

90/162

x

xxxx

110/162

xxxx

Junction, Ø d2125/182

xx

Page 7: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Insulation materialPE-foam hose, PUR-foam pack

CPE

4.310

05.02.2006

T-piece sets and sockets

PUR-foam bottleThe required volume of polyurethane foam is supplied in the appropriate foam bottlepacking sizes for the various sockets and T-pieces. The delivered stick has to bepushed through the foam bottle. The two components are mixed together by anelectrical mixer.

PUR-foam packageBase:CO2-blown, CFC-free PUR-Foam

Security requirement for thefoam insulation

plastic gloves

eye protection

Sockets

Polyethylene foam hose Pipe-extruded insulation of closed cell, high-quality polyethylene, ideally suited forinsulating EIGERFLEX sockets. Various insulation coating thicknesses for the mostcommon pipe diameters.

The insulating material (thickness and length) is supplied for the relevant socket types.The hoses should be adapted exactly to the sockets on the building site.

Page 8: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Pipe FittingsScrewed, welded

CPE

4.320

05.02.2006

Connection coupling Material: brass all dimensions in mm

L

Ø≤75

Ø≥90

L

Screwed PE T-piece Materia: brass

Ø75

Ø90

d2

d2

d1

d1

d3

d3

Alternative types of joint

L

Ø75

Ø90

L

PE-Pipe

25 x 2.332 x 2.940 x 3.750 x 4.663 x 5.875 x 6.890 x 8.2

110 x 10.0

type25 x 2.3-3/4“

32 x 2.9-1“40 x 3.7-11/4“50 x 4.6-11/2“

63 x 5.7-2“75 x 6.8-21/2“

90 x 8.2-3“110 x 10.0-4“

L53636771809292102

type25 x 2.332 x 2.940 x 3.750 x 4.663 x 5.875 x 6.890 x 8.2

110 x 10.0

L606771758189130130

Ø d1 Ø d325 x 2.3-25 x 2.3

32 x 2.9-32 x 2.9

40 x 3.7-40 x 3.7

40 x 3.7-32 x 2.9

50 x 4.6-50 x 4.6

50 x 4.6-40 x 3.7

63 x 5.8-63 x 5.8

63 x 5.8-50 x 4.6

75 x 6.8-75 x 6.8

75 x 6.8-63 x 5.8

90 x 8.2-90 x 8.2

90 x 8.2-75 x 6.8

110x10.0 -110x10.0

110 x10.0-90 x 8.2

Junction, Ø d2

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

25x

2.3

32x

2.9

40x

3.7

50x

4.6

63x

5.8

75x

6.8

90x

8.2

110

x10

Electro-fusion PE fittings or t-pieces *

PE pipe coupling (e.g. Straub or Norma) *

• dimension 125/182, using elecro-fusion PE fittings is suggested

(* not held in stock)

Page 9: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

End capshrinkable

CPE

4.330

05.02.2006

Heat shrinkable end cap

The end cap is shrunk on by applying a gas flame or hot airjet to the end of the pipe.Within dry rooms its application is not absolutely necessary.

Data table

Type

25/7632/7640/9150/9163/12675/12690/162110/162125/182

Shrink end cap

610316103161031863008632686326609996334063340

EIGERFLEX®-Clima

Page 10: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Wall sealing ring Pipe warning tape

CPE

4.340

05.02.2006

50

DDa

ACHTUNG!

FERNWÄRM

ELEITUNG

Wall sealing ring

Pipe warning tape

Tape for laying underground.

Standard length:250 m

Laying depth; see page CPE 4.500

Type

32/76, 25/7640/9150/9163/12675/12690/162110/162125/182

Da118133133168168203203218

Wall sealing ringOuter casing pipe

D789393128128163163183

EIGERFLEX®-Clima

Page 11: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Wall ductCore drilling

CPE

4.345

05.02.2006

DR

1

Exte

rnal

Cellar/

sh

aft

(In

tern

al)

3

4

DR

1

Cellar/

sh

aft

(In

tern

al)

Exte

rnal

2

4

3

Standard sealing ring Sealing ring with additional thrust ring

1 EIGERFLEX®--Clima pipe

2 Thrust ring, large 1 x 40 mm

3 Sealing ringdouble sealing, large 2 x 40 mm,hardness 35 shore

4 Pipe liner made of fibre cement orcoated core drill hole

* Suitability against pressurised water

Core drill holes

Prerequisites for installation are perfect drill holes.Since hairline cracks can exist in concrete or canarise as a result of the work, we recommendsealing the drill hole walls over the entire lengthswith a sealant

We cannot guarantee a good seal if theserecommendations are not observed.

ROuter diameter

EIGERFLEX®-Clima PE Ø mm

7691111126142162183

DPipe liner

Core drill holeØ mm

150150200200250250300

Ø D internal, mm7893113128143163183

Standard ringThrust ring

Ø D external, mm150150200200250250300

Page 12: EIGERFLEX -Clima CPE 4.0 Description · 2020. 5. 20. · EIGERFLEX®-Clima Description CPE 4.0 05.02.2006 4.0 Table of contents 4.1 System description 4.100 System description (data)

EIGERFLEX®-Clima

Trench dimensionsBuilding entry

CPE

4.500

05.02.2006

Trench section, 1 EIGERFLEX®-Clima piping

Building entry

80 80DA

A

D

1 2 3

D

B

T

10

alle Masse in cm

10D

1030

min

60

10

1 Pipe warning tape; see page CPE 4.3402 Excavated material3 Sand washed, grain size 0-3/4 mm

SLW 30 = 50 kN wheel load, resp. 300 kNtotal load according to DIN 1072. Forbigger loads (i.e. SLW 60) a load distribu-tion superstructure according RStO75 isrequired.Without traffic load the minimum coveringhight may be reduced by 20 cm.

Covering hight maximum covering hight: 2.6 mThe higher covering needs our according.

Outhercasing

Ø D mm7693113128143163183

min. bendingradius

m0.70.80.91.01.11.21.5

LargeB

cm25303035353538

DepthT

cm80808585859095

ca 80 mm

60 mm 80 mm

PE-connecting piece, see page CPE 4.320

End cap; see page CPE 4.330 Wall sealing ring, see page CPE 4.340

EIGEFLEX-Pipe,see page CPE 4.110

D

Wall entry

Wall breakthrough Breakthrough boredOutercasing

Ø D mm

7893113128163183

Amm

240250270290320380

Outercasing

Ø D mm

7893113128163183

Dmm

180200220240280300