eei - stencastenca.com/upload/file/cert/panels/dnv-k-600-25... · 2019-11-28 · eei i ir\ri i ttti...

3
EEI I Ir\rI I TTTI 'I II'\II rttt 1l Y @ CERTIFICATE NO. F.T9T64 This Certificate consistsof 3 pages This is to certify that the Class B Bulkhead with typ e de signation( s ) K-600125 815 Bulkhead with cablepenetrations Manufactured by Norac AS ARENDAL, Norway is found to comply with Det Norske Veritas' Offshore Standards Det Norske Veritas' Rules for Classification of Ships Det Norske Veritas' Interpretation of SOLAS 1974 Convention as Amended Application Approved for use as an integratedpart of a vertical fire retarding division of classB-15. For restricted application, seepage2. This certificate is recognizedby Transport Canada. Place and date This Certificate is valid until Hovik,2009-11-09 iol3-t2-31 fpr Dw NonsrcVenrrns AS n , "/ | n | \ ' ll | | ^ I % DH;-- \ \\-W nS---q,n\LA ILL Ittcal ()fttt t(tll ltlnti"=" Petter Langnes I Local Office Headof Section DNV Kristiansand S Surveyor Notice: This Certificate is subject to terrns and conditions overleaf. Aoy signilicant changein designor construction may render this Certificate invalid. The validity date relates to the Type Approval Certifrcate and not to the approval of equipmenUsysterns installed. lfanyper9ngffers|o$ordamagewhichisprvedtohaVeb@n@Usedbyanyneg|igentact DETNORSKEVERnAS AS Form No.:20.90a lssue: January 98 FAX:(+47)67 57 99 11 Page 1 of 3 VERITASVEIEN 1, 1322 HWIK, NORWAY TEL: (+47) 67 s7 99 00

Upload: others

Post on 13-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EEI - Stencastenca.com/upload/File/Cert/Panels/DNV-K-600-25... · 2019-11-28 · EEI I Ir\rI I TTTI 'I II'\II rttt Y 1l @ CERTIFICATE NO. F.T9T64 This Certificate consists of 3 pages

EEII I r \ r II T T T I' I I I ' \ I I

r t t t 1 l

Y

@

CERTIFICATE NO. F.T9T64This Certificate consists of 3 pages

This is to certify that the

Class B Bulkheadw ith typ e de s i gnation( s )

K-600125 815 Bulkhead with cable penetrations

Manufactured by

Norac ASARENDAL, Norway

is found to comply withDet Norske Veritas' Offshore Standards

Det Norske Veritas' Rules for Classification of ShipsDet Norske Veritas' Interpretation of SOLAS 1974 Convention as Amended

ApplicationApproved for use as an integrated part of a vertical fire retarding division of class B-15.

For restricted application, see page2.

This certificate is recognized by Transport Canada.

Place and date This Certificate is valid untilHovik,2009-11-09 iol3-t2-31

fpr Dw Nonsrc Venrrns AS n ,"/ | n | \ ' ll | | ^ I% DH;-- \\\-W nS---q,n\LA ILLIttcal ()fttt t(tll ltlnti"="Petter Langnes I Local Office

Head of Section DNV Kristiansand S Surveyor

Notice: This Certificate is subject to terrns and conditions overleaf. Aoy signilicant change in design or construction may render this Certificate invalid.The validity date relates to the Type Approval Certifrcate and not to the approval of equipmenUsysterns installed.

l fanyper9ngffers|o$ordamagewhichisprvedtohaVeb@n@Usedbyanyneg| igentact

DETNORSKEVERnAS AS

Form No.:20.90a lssue: January 98

FAX: (+47) 67 57 99 11

Page 1 of 3

VERITASVEIEN 1, 1322 HWIK, NORWAY TEL: (+47) 67 s7 99 00

Page 2: EEI - Stencastenca.com/upload/File/Cert/Panels/DNV-K-600-25... · 2019-11-28 · EEI I Ir\rI I TTTI 'I II'\II rttt Y 1l @ CERTIFICATE NO. F.T9T64 This Certificate consists of 3 pages

Cert. No.: F-19164File No.: 471.12

Job Id.: 262.1-008785-l

Product description

"K-6OO{25 B15 bulkhead with cable penetrations"

K-6OO|25 B15 panels consist of a24 mm thick mineral wool core, type Rockwool T150,density 150 kg/m3, covered on the visible/unexposed side with 0.56 mm galvanized steelsheets or two layers of steel sheets type Norac CL with total thickness of 1.5 mm. Thereverse side is covered with 0.4 mm galvanized steel sheets or two layers of steel sheetstype Norac CL with total thickness of 1.5 mm. All interfaces between steeVsteel andsteeUinsulation are glued. The connection of panels can be done either by malelfemaleconnections or loose male and two female joints. A distance channel of 0.75 mm steel isused in each female connection. Standard width of the panels are 585 or 600 mm. Totalpanel thickness is 25 mm.

The panels may be fitted with cable penetrations as described below:

Solution No. l: Single cable penetration sealed with Fireseal 400Fireseal 400 is applied around the cable of type LKM-IIF 5 x 1.5 mm 2 Cu, or equivaleht,all the way though the panel and as a 10 x t2 mm (w x h) brim around the cable at eachside of the bulkhead. Circular hole in panel: Q 30 mm.

Solution No. 3b: Light switch/connection box sealed with steel shelf and Fireseal 400A light switch mounted in a halogen free connection box or depth 45 mm is facing theexposed side. A 150 c 150 x 25 mm (w x h x t) steel box in 9 mm steel is covering theconnexion box on unexposed side. The box is cladded with 6 mm Fibrefrax, except theperimeter and the 25 mm flange, which is cladded with 3 mm Fibrefrax. Two cables of typeLKM-UF 5 x 1.5 mm'Cu, or equivalent, enter the lower part of the steel box, where theopening is sealed with Fireseal400. Circular hole in panel: Q 73 mm.Restricted application: Light switch on exposed side only.

- Solution No. 9: Single cable penetration sealed with Roxtec RS 25Cable fitted with treaded sleeve for Roxtec RS 25, a32by 40 mm brass socket with brassnut on one side. Rubber gasket of thickness 1 mm on socket inside threaded sleeve. Thecable of type LKM-FIF 5 x 1.5 mm2 Cu, or equivalent, is fixed inside the sleeve byexpanding rubber, expanded by tightening expansion screws on one side. Circular hole inpanel: Q 32-33 mm.

Applications/Limitations

For restricted application, see the product description above.

The cable penetrations may be fitted in equivalent bulkheads with thickness at least 25 mm.

Each product is to be supplied with its manual for installation, use and maintenance.

DerNonsrEVBnrr,q.s ASForm No.: 20.90a lssue: January 98

FAX: (+47) 67 57 99 1 1

Page 2 of 3

VERITASVEIEN 1, 1322 H?,IIIK, NORWAY TEL: (+47) 67 57 99 00

Page 3: EEI - Stencastenca.com/upload/File/Cert/Panels/DNV-K-600-25... · 2019-11-28 · EEI I Ir\rI I TTTI 'I II'\II rttt Y 1l @ CERTIFICATE NO. F.T9T64 This Certificate consists of 3 pages

Cert. No.: F-19164File No.: 471.12

Job Id.: 262.1-008785-l

Type Approvaol documentation

Certification in accordance with Certification Note No. 1.2, Type Approval, April 2009.Test report No. GV96.60.1 dated 18 September 1998 from TUV Brandversuchshaus,Hamburg, Germany. Test report No. 103020.11 dated 5 December 2001 and No. 103070.26dated 28 March 2003 from SINTEF NBL, Trondheim, Norway.

Tested according to IMO FTP Code Par:t3 (trUO Res. ,4..754(18)).

Marking of product

The product or packing is to be marked with name of manufacturer, type designation andfire technical rating.

Transport Canada Approval

Based on the procedures laid down in the Transport Canada Publication entitled "ApprovalProcedures for, Ltfe Saving Equipment and Structural Fire Protection Products (TP14612)", Det Norske Veritas confirms that the product listed in this certificate is inaccordance with Transport Canada's requirements.

Certificate retention survey

Det Norske Veritas' surveyor is to be given permission to perform Certification RetentionSurveys at any time during the validity period of this certificate and at least every secondyear. The alrangement is to be in accordance with procedure described in Stdndard for

- Certification No. l.2item4.

END OF CERTIFICATE

i,DETNORSKEVERTTAS AS

Form No.:20.90a lssue: January 98

FAX: (+47) 67 57 99 11

Page 3 of 3

VERITASVEIEN 1, 1322 HAV|K, NORWAY TEL: (+47) 67 57 99 00