Perimeter Mount Installation ........................................................ 2 FL-Inaccessible Installation ....................................................... 3-5 Horizontal Corner Installation ....................................................... 6 Straight Field Cut Illuminated Extension Installation ..................... 7-11 Angled Field Cut Illuminated Extension Installation ................... 12-16 Lens Detail ............................................................................... 17 EDGE Evolution6 INSTALLATION INSTRUCTIONS

Upload: others

Post on 24-Apr-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EDGE Evolution6 INSTALLATION INSTRUCTIONS

Perimeter Mount Installation ........................................................ 2FL-Inaccessible Installation ....................................................... 3-5Horizontal Corner Installation ....................................................... 6Straight Field Cut Illuminated Extension Installation ..................... 7-11Angled Field Cut Illuminated Extension Installation ................... 12-16Lens Detail ............................................................................... 17

EDGE Evolution6 INSTALLATIONINSTRUCTIONS

Page 2: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product.2. Minimum 90ºC supply conductors3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.4. Fixtures must be mounted directly to structure.

1. Remove lens and reflectors.2. Housing mounts to bracket via 1/4 20 hardware.The first fixture in each row requires 2 mount locations all oth-ers require one.

Step 1:Layout/ Dimensions

Perimeter Mount Installation6EDGEE V O L U T I O N

Return toMain Menu

Designed and Fabricated in Denver Colorado Phone: 303.322.5570 www.pinnacle-ltg.com

2 o

f 17

© 2021 Pinnacle Architectural Lighting

EV6_Booklet_OCT2021

“A”

4’

6’

8’

“B”

“C”

“A” “B” “C”

96”

72”

48”

2-5/16”

2-5/16”

2-5/16” 91-7/16”

43-3/8”

67-3/4”

Overall Actual Fixture Length

First Stud Location

Second Stud Location

“E”

“A”

2’

3’

4’

6’

8’

“F”

“A” “E” “F”

95”

71”

47”

35”

23”

36-3/4”

47”

35”

23”

48-3/4” 90-3/8”

42-3/8”

30-3/8”

18-3/8”

66-3/8”

First Stud Location

Overall Actual Fixture Length

Second Stud Location

6’ and 8’ fixtures

4’ fixtures

Dim “B”Dim “C”

Dim “B”Dim “A”

Dim “B” Dim “B”Dim “C”

Dim “A”

6’ and 8’ fixtures

Dim “A”

Dim “A”

Dim “F”

Dim “F”

Dim “E”

Dim “E”

2’ 3’ and 4’ fixtures

First or Intermediate Fixture

Individual or Final Fixture

5-5/8”

Front View

Fixture length can be found on fixture label inside of fixture. An “End Trim” may be used as a gauge for ensuring minimum width. Always install lenses during installation and louvers

AFTER ALL finishing work has been completed.

Fixture Length + 1/2”

Rough-In

6-7/8”5-3/4”

5”

5-13/16”

Page 3: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product.2. Minimum 90ºC supply conductors3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.4. Fixtures must be mounted directly to structure.

Flanged - Inaccessible Installation

Do not screw into side of housing.* *

1. Layout fixture and threaded rod locations. (see page 3)2. Layout and install junction boxes and whip out below ceiling level.3. Install 1/4-20 threaded rod to structure.4. Install ceiling material.5. Cut out the fixture rough-in.

Step 1:Layout/ Dimensions

1. Attach end trim to end fixtures using #6-20 thread forming screws.2. Remove applicable access cover.3. Attach conduit to access cover using 1/2” trade fittings.4. Make electrical connections inside fixture.5. Replace access cover.

Step 2:Making the Connections

6EDGEE V O L U T I O N

Return toMain Menu

Designed and Fabricated in Denver Colorado Phone: 303.322.5570 www.pinnacle-ltg.com

© 2021 Pinnacle Architectural Lighting

EV6_Booklet_OCT2021

1/2” Trade ConduitConnector (by others)

End 1/2” Trade K.O.

1/2” Trade K.O.

Access Cover Screw

Access Cover

1/4-20 Hardware

#6-20 thread forming screws

End trim(End Trims come installed on individual units)

5-5/8”

Front View

5-3/4”

5”

6-1/8”

3-13/16”

1-3/4”

Fixture length can be found on fixture label inside of fixture. An “End Trim” may be used as a gauge for ensuring minimum width. Always install lenses during installation and louvers

AFTER ALL finishing work has been completed.

Fixture Length + 1/2”

Rough-In

(by others)

3 o

f 17

Page 4: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product.2. Minimum 90ºC supply conductors3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.4. Fixtures must be mounted directly to structure.

1. Remove lens or louver and reflector.2. Surface mount fixture through mounting slot to threaded rod.3. If first fixture remove end knock outs for through wiring.

Step 3:Individual or First Fixture

1. Remove lens or louver and reflector.2. Fixtures are through-wired for continuous runs.3. Remove end knock-outs between fixtures.4. Lift and rotate fixture into place.5. Surface mount fixture through mounting slot to threaded rod.6. Make necessary wiring connections between fixtures.7. Align fixtures using supplied biscuits (2) and secure fixtures together using supplied #8-32 screws (2).

Step 4:Continuous Rows

Flanged - Inaccessible Installation6EDGEE V O L U T I O N

Return toMain Menu

Designed and Fabricated in Denver Colorado Phone: 303.322.5570 www.pinnacle-ltg.com

© 2021 Pinnacle Architectural Lighting

EV6_Booklet_OCT2021

Reflector Screw

1/4-20 Hardware(by others)

Reflector

Mounting Slot

Joint holes for #8-32 Screws

Biscuit

4 o

f 17

Page 5: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product.2. Minimum 90ºC supply conductors3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.4. Fixtures must be mounted directly to structure.

1. Re-install reflector.2. Install lens.

Step 5:Finishing

Flanged - Inaccessible Installation6EDGEE V O L U T I O N

Return toMain Menu

Designed and Fabricated in Denver Colorado Phone: 303.322.5570 www.pinnacle-ltg.com

© 2021 Pinnacle Architectural Lighting

EV6_Booklet_OCT2021

Fixture

Reflector

Lens

5 o

f 17

Page 6: EDGE Evolution6 INSTALLATION INSTRUCTIONS

6 o

f 17

Corner Installation Sheet

1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product.2. Minimum 90ºC supply conductors3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.4. Fixtures must be mounted directly to structure.

Corner Piece1. Layout fixture and rough-in location. Fixture requires secondary mains, or blocking along the length of fixture, both sides. (Note: corners are 90º)2. Corners install same as fixture(s) and are required to be tied to structure.3. Remove knock out between fixtures and make necessary wiring con-nections. Join using supplied joining hardware.

Horizontal Corner 6EDGE

E V O L U T I O N

© 2015 Pinnacle Architectural Lighting

Return toMain Menu

EV6_Corners_Booklet_DEC2015Designed and Fabricated in Denver Colorado Phone: 303.322.5570 www.pinnacle-ltg.com

14”

14”

Joint holes for #8-32 Screws

Biscuit

Page 7: EDGE Evolution6 INSTALLATION INSTRUCTIONS

Below are the component pieces required for adjusting and installing the extension. Component pieces are located in the fixture box.

FIELD CUTABLE EXTENSION UNIT BREAKDOWN

Extension Box

End Bracket

End Cap

LED Reflector Assembly

STRAIGHTEXTENSIONEV6

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 EV6_FeildCutExtensions_OCT2021

PAGE 7 of 17

Page 8: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1 EXTENSION BOX PREP

Length

2 END BRACKET SETUP

Measure from this end

Measure the desired length of the final assembled fixture (Extension Box + Main Fixture). Measure the required length from the end of the extension box. Make sure to measure from the end that attached to the main fixture.

After cutting the extension box, locate end bracket. Attach end bracket to the open end of the extension box via 4 screws on side. This side will be what con-nects to the main fixture.

STRAIGHTEXTENSIONEV6

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 EV6_FeildCutExtensions_OCT2021

PAGE 8 of 17

Page 9: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1 EXTENSION BOX ASSEMBLY 2 LED EXTENSION INSTALLATION

Final AssemblyLED Board

Reflector

Reflector Bracket

The LED assembly is made up of 3 parts. The LED board, the reflector, and the bracket. All three are connected using screws. 4 screws in the corners of the reflector secure the reflector to the bracket. And 3 screws in the center of the reflector secure the LED board to the reflector.

Install the LED reflector assembly as shown below using (4) screws/rivets from the kit. Secure the parts in the top row of holes when viewing from a room view perspective. (note: the LED board in the exention box will sit “above”, when viewing from a room side, the main fixture’s LED board.)

STRAIGHTEXTENSIONEV6

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 EV6_FeildCutExtensions_OCT2021

PAGE 9 of 17

Page 10: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1 EXTENSION BOX INSTALLATION 2 RAIL TRIMMING

Joint Detail

Trim

Take the illuminated extension and connect the LED wires to the wires protruding from the main fixture. It is recommended to store any excess wiring in extension box. Slide the extension in between the rails and flush with fixture housing. Secure housing and extension together using two screws one for each side of the bracket.

Finish securing of extension to housing with two (2) additions screws, one for each side of the fixture. Once extension is full secured to main fixture trim the excess rails to be flush with end of extension. Once rails and extension box are flush install end cap with 2 screws to finish housing.

STRAIGHTEXTENSIONEV6

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 EV6_FeildCutExtensions_OCT2021

PAGE 10 of 17

Page 11: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1 TRIM LENS AND INSTALL

Measure from main fixture side of lens

Length

Select and measure the desired lens length. The lens included in the kits are lon-ger than required. Lens material expands with the heat of the LED boards. Run the saw at full speed and cut the lens slowly to avoid fracture and/or cracking. To account for this, subtract 1/32” from the total desired fixture length to account for thermal expansion. (i.e. 96” fixture takes a total or combined lens length of 95.969”)

DISCLAIMERSA carbide tipped saw blade for aluminum is recomended for cutted the extension box.An AGE MD12-962 Industrial Carbide tipped plastic saw blade is recommended for cutting the lens.This product must be installed in accordance with applicable installation and electrical codes by aprofessional familiar with the construction and operation of the product.Minimum 90° C supply conductor.

All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.Damaged components must never be used.Contact Pinnacle prior to making any fixture alterations.Contact Pinnacle with any installation questions or field issues.

STRAIGHTEXTENSIONEV6

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 EV6_FeildCutExtensions_OCT2021

PAGE 11 of 17

Page 12: EDGE Evolution6 INSTALLATION INSTRUCTIONS

Below are the component pieces required for adjusting and installing the extension. Component pieces are located in the fixture box.

FIELD CUTABLE EXTENSION UNIT BREAKDOWN

LED Reflector Assembly

Extension Box

End Bracket

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570

EXTENSIONINSTALLATIONEV6

EV6_FeildCutExtensions_OCT2021

PAGE 12 of 17

Page 13: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1 EXTENSION BOX PREP

Length

2 END BRACKET SETUP

TabsTab

Fold side tabs

Measure from this end

Angle

Measure the desired length and angle of the final assembled fixture (Extension Box + Main Fixture). Measure the required length from the end of the extension box. Make sure to measure from the end that attached to the main fixture.

After cutting the extension box, locate end bracket. Fold the end brackets’s tabs to a position that will minimize the gap between the extension box and the end bracket. The additional tabs may be cut if desired.

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570

EXTENSIONINSTALLATIONEV6

EV6_FeildCutExtensions_OCT2021

PAGE 13 of 17

Page 14: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1 EXTENSION BOX ASSEMBLY 2 LED EXTENSION INSTALLATION

Secure the end bracket to the cut end of the extension box. Utilize 3 screws/rivets from kit and place them in the locations as shown below.

Install the LED board and reflector assembly as shown below using (4) screws/rivets from the kit. Secure the parts in the top row of holes when viewing from a room view perspective. (note: the LED board in the exention box will sit “above”, when viewing from a room side, the main fixture’s LED board.)

Final assembly

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570

EXTENSIONINSTALLATIONEV6

EV6_FeildCutExtensions_OCT2021

PAGE 14 of 17

Page 15: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1 EXTENSION BOX INSTALLATION 2 RAIL TRIMMING

Trim

Joint Detail

Take the illuminated extension and connect the LED wires to the wires protruding from the main fixture. It is recommended to store any excess wiring in extension box. Slide the extension in between the rails and flush with fixture housing. Secure housing and extension together using two screws one for each side of the bracket.

Once extension is installed to main fixture trim the excess rails to be flush with end of extension.

Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570

EXTENSIONINSTALLATIONEV6

EV6_FeildCutExtensions_OCT2021

PAGE 15 of 17

Page 16: EDGE Evolution6 INSTALLATION INSTRUCTIONS

1 TRIM LENS AND INSTALL

Measure from main fixture side of lens

Length

Angle

Select and measure the desired lens length and angle. The lens included in the kits are longer than required. Lens material expands with the heat of the LED boards. Run the saw at full speed and cut the lens slowly to avoid fracture and/or cracking. To account for this, subtract 1/32” from the total desired fixture length to account for thermal expansion. (i.e. 96” fixture takes a total or combined lens length of 95.969”)

DISCLAIMERSA carbide tipped saw blade for aluminum is recomended for cutted the extension box.An AGE MD12-962 Industrial Carbide tipped plastic saw blade is recommended for cutting the lens.This product must be installed in accordance with applicable installation and electrical codes by aprofessional familiar with the construction and operation of the product.Minimum 90° C supply conductor.

All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.Damaged components must never be used.Contact Pinnacle prior to making any fixture alterations.Contact Pinnacle with any installation questions or field issues.

EV6_FeildCutExtensions_OCT2021Designed in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570

EXTENSIONINSTALLATIONEV6

PAGE 16 of 17

Page 17: EDGE Evolution6 INSTALLATION INSTRUCTIONS

17 o

f 17

Snap In LensLensing detail sheet

Lens Installation Lens Removal1. Begin at one end of the lens and squeeze sides to allow it to flex. 2. Insert end of lens into place, lens will snap into place when installed properly.3. Slowly insert rest of lens down the length of the fixture

1. Insert a rigid object approx. 1/16” thick, such as a putty knife, into the edge between the lens and the fixture side about one inch from end.2. Using said object, gently pry lens away from fixture until it is released from the mounting edge.3. Once the section is released, start at that end of the fixture and pull the lens out of the fixture.

Fixture End

Snap-In LensOpen lens from here

Drop Lens - Do Not Push OnEnd Of Lens

Flat Lens Shown

Remove lens using sides of lens. DO NOT PUSH ON END OF LENS

Note: Low temperatures can effect the lens material, making it brittle. lease allow the lenses to warm to room temperature before installation.

6EDGEE V O L U T I O N

© 2021 Pinnacle Architectural Lighting

Return toMain Menu

EV6_Booklet_OCT2021Designed and Fabricated in Denver Colorado Phone: 303.322.5570 www.pinnacle-ltg.com