CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflec-tive die-formed white painted steel reflector, .125” white snap-in acrylic lens with matte finish, removable for lamp replacement.
ELECTRICAL T5, T5HO: Standard programmed start UL listed Class P, T5 electronic, sound rated A, thermally protected, high power factor ballasts less than 10% THD, universal voltage (120-277) with 50/60Hz operation. Standard single circuit. Each ballast provided with disconnects to meet luminaire disconnect code requirement.
LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted.
L U M I N A I R E S P E C I F I C A T I O N
EV3SCO- 1T5__- ___- ___- __-
1T5-1T5HO-
(1) T5 (1) T5HO
Matte WhiteMetallic SilverTextured BlackGraphiteBronzeCustom Color
W-S-BL-GR-BR-CC-
Sample Catalog #: EV3SCO-1T5-FL-120-1C-W
120-277-347-UNV-
120 V277 V347 V2
UNV2
(120-277)
1C-1D-1B-
1E-
Single CircuitSingle Circuit Dimming3
Single Circuit with Battery Pack2, 3
Single Circuit with Emergency Circuit3
__-
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
EV3SCO- Edge Evo-lution 3, Staggered Outside Corner, Satine Lens4
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2016 Pinnacle Architectural Lighting® February 2016
HOUSING LAMPS MOUNTING VOLTAGE CIRCUITING5 FINISH
Standard 1/2” FlangeSpackle FlangeFlangeless1
FL-SF-NF-
Inaccessible Ceiling
EV3SCOT5, T5HO, T8 EV3 Outside Illuminated CornerFor use with Edge Evolution 3 Staggered
Project Name
TypeCatalog Number
DateEDGEE V O L U T I O N
1NF to be utilized for metal pan/ millwork ceilings. 2347v and UNV not available with battery pack. 3Some Edge configurations will not accommodate all electrical options. Consult Factory. 4Corner avail-able with satine lens only. 5Corner units are wired for circuiting to match standard fixture in pattern. No ballast, battery, or other will be inside corner unit. 6 See page 3 for grid retention bracket details.
5-1/8”
3”G1/G9/GS: 3-13/16”
FL & FLF: 4”
5-1/8”
3”G1/G9/GS: 3-13/16”
15”
15”
FL: 4-1/8”
Utilize EV3SCO Specification sheet for Specifying corner unit only.
YEAR LEDWARRANTY
ConvertibleLED
ConvertibleLFL
LFL LED
YEAR LEDWARRANTY
ConvertibleLED
ConvertibleLFL
LFL LEDLampsStaggered
LampsStaggered
MOUNTING Edge is designed to install into acoustical grid and inaccessible ceilings. Specify GX, FL, SF, NF for ceiling type. Outside 90º corner easily joins to standard Edge Evolution 3 staggered units. Grid retention brackets are integral to housing. Each housing contains 4 grid retention brackets. Consult factory for detailed installation instructions.
(1) Lens per Ouside corner unit.
FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish, consult factory for chip of standard paint finishes. Contact factory for additional custom color and finish options.
G1-G9-GB-GS-
1” Ceiling Grid9/16” Ceiling Grid9/16” Ceiling Grid with Bevel TrimScrew Slot Ceiling Grid
Acoustical Grid Ceiling6
E D G E E V O L U T I O N 3 / 9 0 ° O U T S I D E C O R N E R
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2016 Pinnacle Architectural Lighting® February 2016
MOUNTING DETAILS
Metal Pan or Millwork: Specify NF or NFN in part #
Drywall, Flangeless Look: Specify SF or SFS in part #
Flange Detail Non-Flange Spackle Flange
Exposed Flange Detail: Specify FL or FLF in part #
Metal Pan or Millwork: Specify NF or NFN in part #
Drywall, Flangeless Look: Specify SF or SFS in part #
Flange Detail Non-Flange Spackle Flange
Exposed Flange Detail: Specify FL or FLF in part #
1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot Mounting
Screw Slot Grid: Use GS or GSG in part #
9/16” Grid, Tegular Tile: Use GS or GSG in part #
9/16” Grid, Tegular Tile: Use GB or GBG in part #
9/16” Grid, Tegular Tile: Use G9 or G9G in part #
9/16” Grid, Standard Tile: Use G9 or G9G in part #
1” Grid, Tegular Tile: Use G1 or G1G in part #
1” Grid, Standard Tile: Use G1 or G1G in part #
1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot Mounting
Screw Slot Grid: Use GS or GSG in part #
9/16” Grid, Tegular Tile: Use GS or GSG in part #
9/16” Grid, Tegular Tile: Use GB or GBG in part #
9/16” Grid, Tegular Tile: Use G9 or G9G in part #
9/16” Grid, Standard Tile: Use G9 or G9G in part #
1” Grid, Tegular Tile: Use G1 or G1G in part #
1” Grid, Standard Tile: Use G1 or G1G in part #
LAYOUT
Corner
Edge Evolution 3Staggered Unit
Edge Evolution 3Staggered Unit
CONFIGURATION The EV3SCO is des igned to work wi th s taggered Edge Evo lu t ion 3 p roduct to a l low fo r the c reat ion o f un ique pat te rns and cont inue a l ight ing theme th roughout more spaces . See the EV3A spec sheets fo r more in fo rmat ion .
E D G E E V O L U T I O N 3 / 9 0 ° O U T S I D E C O R N E R
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2016 Pinnacle Architectural Lighting® February 2016
G R I D R E T E N T I O N B R A C K E T
Joint holes for #8-32 Screws
Biscuit
Joint holes for #8-32 Screws
Biscuit
GRID RETENTION: At every joint, the addition of grid retention brackets results in a sturdy connection between the fixtures and the grid. Insert screws through the bracket into the grid to secure.
JOINT ALIGNMENT: Incor-porating biscuits and screws not only creates a secure joint but also aids in fixture alignment.