eco monitor pro

16
1 MITSUBISHI Energy Measuring Unit EMU2 EMU2 - - RD3 RD3 - - C (for 3 circuits) C (for 3 circuits) EMU2 EMU2 - - RD7 RD7 - - C (for 7 circuits) C (for 7 circuits)

Upload: andrew-maverick

Post on 28-Nov-2015

47 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Eco Monitor Pro

1

MITSUBISHI Energy Measuring Unit

EMU2EMU2--RD3RD3--C (for 3 circuits)C (for 3 circuits) EMU2EMU2--RD7RD7--C (for 7 circuits)C (for 7 circuits)

Page 2: Eco Monitor Pro

2

Measuring energy enables to visualize waste and loss of energy, and it supports energy saving activities.

1) For monthly result management2) For departmental control of energy usage

3) For recording and managing energy data

•Obtain a basic unit by using energy usage and production quantity in a production line and facilities, and analyze it as a productivity index;

1) Analyze energy waste and loss in production line

2) Be aware of facility operation3) Analyze for operation improvement, such as production

process improvement and efficient operating condition

Don’t overlook waste of energy!!

Unit control helps to improve productivity.

Page 3: Eco Monitor Pro

3

1. The concept of 1. The concept of EcoMonitorEcoMonitorProPro

•Package(1) Wider range of product line-up

Meet the needs of various circuit conditions.

Lineup: 3, 5, 7 circuits (for 3P3W/1P2W), 2, 4 circuits (for 3P4W)

(2) Low voltage to high voltageIncoming circuits (high voltage) and distribution circuits (low voltage) are

measurable with one unit.

•Flexible(1) Measurement according to use

It can set different display items by every circuit

(2) Multiple transformer systems measurable with one unit(3) Display unit

Measuring data on multiple circuits displayable with one display unit.

(4) Sensor cableAdjustable to appropriate length as needs.

Package Flexible

Page 4: Eco Monitor Pro

4

Model name

EMU2-RD3-C

EMU2-RD5-C

EMU2-RD7-C

EMU2-RD2-C-4W

EMU2-RD4-C-4W

EMU2-RD3-FEMU2-RD5-FEMU2-RD7-FEMU2-RD2-F-4W

EMU2-RD4-F-4W

EMU2-CM-C

EMU2-D65

EMU2-D65M

EMU2-PK3-EN

EMU2-CT5

EMU2-CT5-4W

EMU-CT50

EMU-CT100

EMU-CT250

EMU-CT400

EMU-CT600

EMU2-CB1-DR

EMU2-CB1-DR-4W

EMU2-CB-T1M

EMU2-CB-T5M

EMU2-CB-T10M

EMU2-CB-T1MS

EMU2-CB-T5MS

EMU2-CB-T10MS

Main unit

Peripheral

equipment

Split-type current sensor (for 5A)

Split-type current sensor

Current sensor cable/Extention cable

CC-Link communication module

Display unit

Logging display unit

Data collection PC kit

Product name

Energy Measuring Unit

CC-Link

1Φ 2W

3Φ 3W

3Φ 4W

Non

communication

1Φ 2W

3Φ 3W

3Φ 4W

22. . ProductProduct llineupineup

Page 5: Eco Monitor Pro

5

3.13.1 Suitable configurationSuitable configuration

Wide selection to suite the number of circuitsWide selection to suite the number of circuits

3. Characteristic3. Characteristic

For 3P3W/1P2WFor 3P3W/1P2W

For 3P4WFor 3P4W

EMU2-RD3-C (for 3 circuits) EMU2-RD5-C (for 5 circuits) EMU2-RD7-C (for 7 circuits)

EMU2-RD2-C-4W (for 2 circuits) EMU2-RD4-C-4W (for 4 circuits)

Page 6: Eco Monitor Pro

6

System extension possible by adding communication moduleSystem extension possible by adding communication module

3.23.2 System extensibilitySystem extensibility

System extension according to budgetSystem extension according to budgetSystem extension according to budget

EcoMonitorPro

(Non communication type)

CC-Link communication module

Page 7: Eco Monitor Pro

7

Incoming circuit (High voltage) and distribution circuit (Low voIncoming circuit (High voltage) and distribution circuit (Low voltage)ltage)

can be measured at 1 unitcan be measured at 1 unit

Current sensorCurrent sensor

EMUEMU--CT250CT250

Low voltageLow voltageLow voltage

EMU2EMU2--RD3RD3--CC

High voltageHigh voltageHigh voltage

3.33.3 HighHigh/Low voltage at 1 unit/Low voltage at 1 unit

Page 8: Eco Monitor Pro

8

Multi trans system can be measured at 1 unitMulti trans system can be measured at 1 unit

Current sensorCurrent sensor

EMUEMU--CT250CT250

AirAir--conditioningconditioning LightingLighting

EMU2EMU2--RD5RD5--CC

3.3.4 4 HighHigh/Low voltage circuit can be measured at 1 unit/Low voltage circuit can be measured at 1 unit

Page 9: Eco Monitor Pro

9

••Multiple circuits displayed with one display unitMultiple circuits displayed with one display unit

••A display unit can be installed on an IEC rail or a panel board.A display unit can be installed on an IEC rail or a panel board.

EMU2EMU2--RD7RD7--CC

Display unitDisplay unit

EMU2EMU2--D65D65

(1) Panel mounting(1) Panel mounting (2) IEC rail mounting(2) IEC rail mounting

IEC railIEC rail

Switching boardSwitching board29mm29mm

LCD display with

backlight

3.3.5 Display unit (5 Display unit (Easily view, easily attachment)Easily view, easily attachment)

Page 10: Eco Monitor Pro

10

It can share one display unit with multi It can share one display unit with multi EcoMinitorProEcoMinitorPro..

EMU2EMU2--RD7RD7--CC

Display unitDisplay unit

EMU2EMU2--D65D65

EMU2EMU2--RD7RD7--CC

SharableSharable

3.3.5 Display unit (5 Display unit (Easily view, easily attachment)Easily view, easily attachment)

Page 11: Eco Monitor Pro

11

Current sensorCurrent sensor

EMUEMU--CT250CT250

Sensor cableSensor cable

0.5m0.5m

ExtentionExtention cablecable

Adjustable to appropriate length in 1, 5, Adjustable to appropriate length in 1, 5,

and 10m. (Max. 50m)and 10m. (Max. 50m)

EMU2EMU2--RD7RD7--CC

3.3.6 6 Current sensor cableCurrent sensor cable

Page 12: Eco Monitor Pro

12

Easier installation by a splitEasier installation by a split--type 5A current sensortype 5A current sensor

SplitSplit--type 5A current sensortype 5A current sensorEMU2EMU2--CT5CT5

Existing CTExisting CT

**/5A**/5A

3.3.7 7 SplitSplit--type 5A current sensortype 5A current sensor

Page 13: Eco Monitor Pro

13

Energy saving data analysis is easily possible by logging displaEnergy saving data analysis is easily possible by logging display unity unit

Logging display unitLogging display unit

EMU2EMU2--D65D65--MM

Communication cableCommunication cable

Software

installation

Logging data storage

3.3.8 8 OffOff--line loggingline logging

Page 14: Eco Monitor Pro

14

2circuits/3circuits 12hours

4circuits/5circuits 4hours

7circuits 2hours

1min data

1hour data

Wh + selected 3 items

1sec/ 1min/ 1hour

10 days

131 days

Logging cycle

1sec data

Logging period

Storable data

•Easy loggingMeasured data can be stored by connecting logging display unit to an EcoMonitorPro.

Second/minute/hour-scale cycle data stored immediately.

•One-touch simple connectionDirectly connected to a PC without a network connection.

•Data collectionCollect stored data on a PC and exchange CSV file format.

3.3.8 8 OffOff--line loggingline logging

Page 15: Eco Monitor Pro

15

3.3.8 8 OffOff--line loggingline logging

Page 16: Eco Monitor Pro

16

High accuracy measurement ASIC

•High accuracy (Accuracy: ±±±± 1.0%)

•The number of measurable items: 9 items

•Short cycled load (ex: spot-welding machine) can be

measure.

A/D converter

Voltage Current

Low pass filter

Amplitude and Phase

correction

Wh data output

Co

llec

tion

circ

uit

(Fre

qu

en

cy)

Co

llec

tion

circ

uit

(Lo

ad

pro

pe

rty)

A/D converter

-Measurable items-

•Current (A)

•Voltage (V)

•Electric power (W)

•Reactive power (var)

•Power factor (cosΦ)

•Frequency (Hz)

•Harmonic current (HA)

•Harmonic voltage (HV)

•Electric energy (Wh)

•Reactive energy (varh)

-Measurable items-

•Current (A)

•Voltage (V)

•Electric power (W)

•Reactive power (var)

•Power factor (cosΦ)

•Frequency (Hz)

•Harmonic current (HA)

•Harmonic voltage (HV)

•Electric energy (Wh)

•Reactive energy (varh)

3.3.9 9 High performanceHigh performance