2
EBARA CONSTANT SPEED PRESSURE BOOSTER UNIT MODEL UD2 DIMENSIONS Max. Approx. 900 260 Approx. 340 Discharge Suction 145 145 290 Max. Approx. 450 H2 Approx. H1 Discharge H2 Max. Approx. 1100 100 100 Suction W Max. Approx.800 Approx. H1 200 300 L 100 300 160 L 100 W Approx. 650 Max. Approx. 1200 Max. Approx. 550 Discharge Suction H2 Approx. H1 H2 Discharge Suction Max. Approx. 1300 360 Max. Approx. 750 160 620 100 100 L Approx. H1 Pressure tank 3M32 : 1 piece 3M40 : 2 pieces Approx. 425 20 20 25 25 160 Model kW Ds UD2-S CDX120/12 H1 H2 UD2-S CDX120/20 UD2-S 2CDX120/15 UD2-S 2CDX120/20 UD2-S 2CDX120/30 UD2-S 2CDX120/40 UD2-S CDX200/20 UD2-S CDX200/25 UD2-S 2CDX200/30 UD2-S 2CDX200/40 UD2-S 2CDX200/50 R 1 1/4 Ds Dd Ds (DIN 10bar Flange) Model kW Ds Dd UD2-S 3M32-160/2.2 H1 H2 L UD2-S 3M32-200/3.0 UD2-S 3M32-200/4.0 UD2-S 3M32-200/5.5 UD2-S 3M40-160/3.0 UD2-S 3M40-160/4.0 UD2-S 3M40-200/5.5 UD2-S 3M40-200/7.5 UD2-S 3M40-200/11 Model kW Ds Dd H1 H2 0.9 1.5 1.1 1.5 2.2 3.0 1.5 1.8 2.2 3.0 3.7 G 1 1/4 G 1 1/4 G 1 1/4 G 1 1/4 G 1 1/4 G 1 1/4 G 1 1/2 G 1 1/2 G 1 1/2 G 1 1/2 G 1 1/2 UD2-D CDX120/12 UD2-D CDX120/20 UD2-D 2CDX120/15 UD2-D 2CDX120/20 UD2-D 2CDX120/30 UD2-D 2CDX120/40 UD2-D CDX200/20 UD2-D CDX200/25 UD2-D 2CDX200/30 UD2-D 2CDX200/40 UD2-D 2CDX200/50 0.9 1.5 1.1 1.5 2.2 3.0 1.5 1.8 2.2 3.0 3.7 G 1 1/4 G 1 1/4 G 1 1/4 G 1 1/4 G 1 1/4 G 1 1/4 G 1 1/2 G 1 1/2 G 1 1/2 G 1 1/2 G 1 1/2 UD2-D CMA 1.00 UD2-D CDX 90/10 0.75 0.75 G 1 G 1 1/4 2.2 3.0 4.0 5.5 3.0 4.0 5.5 7.5 11 Ds Dd Dd ( DIN 10bar Flange) Ds (DIN 10 bar Flange) Ø50 R1 1/2 Ø65 R 2 Ø50 R1 1/2 Ø50 R1 1/2 Ø50 R1 1/2 Ø65 R 2 Ø65 R 2 Ø65 R 2 Ø65 R 2 W UD2-D 3M32-160/2.2 UD2-D 3M32-200/3.0 UD2-D 3M32-200/4.0 UD2-D 3M32-200/5.5 UD2-D 3M40-160/3.0 UD2-D 3M40-160/4.0 UD2-D 3M40-200/5.5 UD2-D 3M40-200/7.5 UD2-D 3M40-200/11 2.2 3.0 4.0 5.5 3.0 4.0 5.5 7.5 11 Ø50 Ø65 Ø50 Ø50 Ø50 Ø65 Ø65 Ø65 Ø65 Model kW Ds Dd H1 H2 L 465 486 465 465 486 486 465 486 465 486 486 206 218 206 206 218 218 206 218 206 218 218 625 675 675 675 650 650 695 695 695 232 232 260 260 260 232 260 260 260 410 410 410 410 410 410 410 410 520 675 695 675 675 695 695 675 695 675 695 695 677 675 206 218 206 206 218 218 206 218 206 218 218 197 206 480 480 480 480 480 480 480 480 480 480 510 480 480 755 805 805 805 800 800 850 850 850 232 232 260 260 260 232 260 260 260 520 520 520 560 520 520 560 560 650 48 57 57 63 72 64 77 89 100 Weight Weight 31 35 34 36 42 45 33 36 44 44 51 Weight 61 68 66 69 82 88 65 70 86 86 102 59 59 R 1 1/2 R 1 1/2 R 1 1/2 R 1 1/2 R 1 1/2 R 1 1/2 R 2 R 2 R 2 R 2 R 2 R 1 1/4 R 1 1/4 106 119 132 150 111 125 152 175 198 Weight Ø65 Ø80 Ø65 Ø65 Ø65 Ø80 Ø80 Ø80 Ø80 DIMENSION TABLE DIMENSION TABLE DIMENSION TABLE DIMENSION TABLE Unit : H1 to W (mm) Weight (kg) Unit : H1 to H2 (mm) Weight (kg) L 385 430 25 25 W 340 350 340 340 340 340 340 340 340 430 430 430 430 430 430 430 430 430 430 430 160 MODEL UD2-S CDX & 2CDX MODEL UD2-S 3M MODEL UD2-D CMA, CDX & 2CDX MODEL UD2-D 3M Note : (1) kW is shown output per 1 pump. (2) All specifications subject to prior notice. NORMAL PRESSURE BOOSTER UNIT Unit : H1 to W (mm) Weight (kg) Unit : H1 to L (mm) Weight (kg)

Upload: others

Post on 14-Apr-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EBARA CONSTANT SPEED PRESSURE BOOSTER UNITebara.com.hk/UPFILE/Productload/20171320434115.pdf · EBARA CONSTANT SPEED PRESSURE BOOSTER UNIT MODEL UD2 DIMENSIONS Max. Approx. 900 260

EBARA CONSTANT SPEEDPRESSURE BOOSTER UNITMODEL UD2

DIMENSIONSM

ax. A

ppro

x. 9

00

260

Approx. 340

Discharge

Suction

145 145290

Max.Approx. 450

H2 A

ppro

x. H

1Discharge

H2

Max

. App

rox.

110

0

100 100

Suction

W

Max.Approx.800

App

rox.

H1

200

300L

100

300 160

L100

W

Approx. 650

Max

. App

rox.

120

0

Max. Approx. 550

Discharge

Suction

H2

App

rox.

H1

H2

Discharge

Suction

Max

. App

rox.

130

0

360Max. Approx. 750

160

620100 100

L

App

rox.

H1

Pressure tank3M32 : 1 piece3M40 : 2 pieces

Approx. 425

20 20 25 25

160

Model kW DsUD2-S CDX120/12

H1 H2

UD2-S CDX120/20UD2-S 2CDX120/15UD2-S 2CDX120/20UD2-S 2CDX120/30UD2-S 2CDX120/40UD2-S CDX200/20UD2-S CDX200/25UD2-S 2CDX200/30UD2-S 2CDX200/40UD2-S 2CDX200/50

R 1 1/4

Ds

Dd

Ds(DIN 10bar

Flange)

Model kW Ds DdUD2-S 3M32-160/2.2

H1 H2 L

UD2-S 3M32-200/3.0UD2-S 3M32-200/4.0UD2-S 3M32-200/5.5UD2-S 3M40-160/3.0UD2-S 3M40-160/4.0UD2-S 3M40-200/5.5UD2-S 3M40-200/7.5UD2-S 3M40-200/11

Model kW Ds Dd H1 H2

0.9 1.5 1.1 1.5 2.2 3.0 1.5 1.8 2.2 3.0 3.7

G 1 1/4G 1 1/4

G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2

UD2-D CDX120/12UD2-D CDX120/20UD2-D 2CDX120/15UD2-D 2CDX120/20UD2-D 2CDX120/30UD2-D 2CDX120/40UD2-D CDX200/20UD2-D CDX200/25UD2-D 2CDX200/30UD2-D 2CDX200/40UD2-D 2CDX200/50

0.9 1.5 1.1 1.5 2.2 3.0 1.5 1.8 2.2 3.0 3.7

G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/2G 1 1/2G 1 1/2G 1 1/2G 1 1/2

UD2-D CMA 1.00UD2-D CDX 90/10

0.75 0.75

G 1 G 1 1/4

2.2 3.0 4.0 5.5 3.0 4.0 5.5 7.5 11

Ds

Dd

Dd( DIN 10barFlange)

Ds(DIN 10 bar

Flange)

Ø50 R1 1/2

Ø65 R 2

Ø50 R1 1/2Ø50 R1 1/2Ø50 R1 1/2

Ø65 R 2

Ø65 R 2

Ø65 R 2Ø65 R 2

WUD2-D 3M32-160/2.2UD2-D 3M32-200/3.0UD2-D 3M32-200/4.0UD2-D 3M32-200/5.5UD2-D 3M40-160/3.0UD2-D 3M40-160/4.0UD2-D 3M40-200/5.5UD2-D 3M40-200/7.5UD2-D 3M40-200/11

2.2 3.0 4.0 5.5 3.0 4.0 5.5 7.5 11

Ø50

Ø65

Ø50Ø50Ø50

Ø65Ø65Ø65Ø65

Model kW Ds Dd H1 H2 L

465 486 465 465 486 486 465 486 465 486 486

206 218 206 206 218 218 206 218 206 218 218

625 675 675 675 650 650 695 695 695

232

232

260260260

232260260260

410

410

410410410

410410410520

675 695 675 675 695 695 675 695 675 695 695

677 675

206 218 206 206 218 218 206 218 206 218 218

197 206

480 480 480 480 480 480 480 480 480480 510

480 480

755 805 805 805 800 800 850 850 850

232

232

260260260

232260260260

520 520 520 560 520 520 560 560 650

48

57

576372

647789

100

WeightWeight 31 35 34 36 42 45 33 36 44 44 51

Weight

61 68 66 69 82 88 65 70 86 86

102

59 59

R 1 1/2R 1 1/2R 1 1/2R 1 1/2R 1 1/2R 1 1/2

R 2

R 2R 2

R 2R 2

R 1 1/4R 1 1/4

106 119 132 150 111 125 152 175 198

Weight

Ø65

Ø80

Ø65Ø65Ø65

Ø80Ø80Ø80Ø80

DIMENSION TABLE DIMENSION TABLE

DIMENSION TABLE DIMENSION TABLE Unit : H1 to W (mm) Weight (kg)

Unit : H1 to H2 (mm) Weight (kg)

L 385

430

25 25

W

340

350

340340340

340340340340

430 430 430 430 430

430 430 430 430 430 430

160

MODEL UD2-S CDX & 2CDX MODEL UD2-S 3M

MODEL UD2-D CMA, CDX & 2CDX MODEL UD2-D 3M

Note : (1) kW is shown output per 1 pump. (2) All specifications subject to prior notice.

NORMAL PRESSURE BOOSTER UNIT

Unit : H1 to W (mm) Weight (kg)

Unit : H1 to L (mm) Weight (kg)

Page 2: EBARA CONSTANT SPEED PRESSURE BOOSTER UNITebara.com.hk/UPFILE/Productload/20171320434115.pdf · EBARA CONSTANT SPEED PRESSURE BOOSTER UNIT MODEL UD2 DIMENSIONS Max. Approx. 900 260

NORMAL PRESSURE BOOSTER UNITMODEL UD2

APPLICATIONS

1. Domestic : High-rise buildings, Condominiums, Apartments etc.2. Commercial : Office buildings, Hotels, Shopping centres etc.3. Industrial : High-rise factories, Manufacturing & processing industries applications etc.4. Social service : Schools, Hospitals etc.

Hydro-pneumatic tank Uses approved diaphragmsuitable for potable water

Control panelUses approved diaphragmControls pumps operationfrom pressure and flow switches

Discharge pipeIntegrated manifold typeRobust & reliable construction.

Flow switchDetects very low flow to cut offoperating pump thus reducingfrequency of on / off pump atlow flow

Pressure switchesAdjustable type - signal cut-in andcut-out of pumps

Steel baseIntegrating all components asa single unit

PumpRobust & high grade materialsprovide long life reliable operation

Pressure gaugeIndicator of water pressuret

Check valveQuick closing action reduceswater hammer

CONTROL SYSTEM

6

S ing leO pera tion

P ara lle lO pera tion

Q 1F low sw itch

opera tion rangeC ontinuous pum p

U ncontinuouspum p opera tionrange

Step 1) Both pumps are stopped when water tank is fully charged. In this condition water is supplied from the pressure tank, and water pressure in tank gradually decreases.Step 2) No.1 pump starts at pressure P1 (Point ) and water is Supplied from pump (and pressure tank)

Step 3) When more water is required and water pressure decreases to P2(Point ), No.2 pump also starts, operation point shifts to Point

and system shifts to parallel operation

Step 4) When water consumption decreases, water pressure in tank increases and when pressure reaches P3 (Point ), No.2 pump is stopped and operation point shifts to point .

Step 5) When water consumption further decreases, water pressure in tank increases and pressure switch is turned off, and the flow switch used to detect small flow, is turned off. When both pressure and flow switches are off, No.1 pump stops (Point ). Flow switch setting point is at small capacity point, therefore pump continuous operation range is much wider. Accordingly pump start frequency is greatly decreased.

1. All components are integrated on a rugged steel base. It is ready for use by only connecting with supply piping and to the power source.2. Layout is very compact and much lighter than conventional units. It occupies lesser space and requires easier installation than conventional units.3. The flow control system which prevents frequent start and stop of pumps, requires only small hydro-pneumatic pressure tank and ensures

constant fresh water supply.4. Pumps are in parallel operation for high demand and alternating in low demand, suitable for energy saving.(Model UD2-D)5. Various options are available on request.

FEATURES

6

5

1

2

3

4P 4

P 1

P 2

P 3

SELECTION CHART AND MODEL CODE

Pressure Booster Unit Model Code

UD2 -S CDX 90/10Pump model

Operation system

Constant speed pressure booster

S : 1 Pump operation systemD : 2 Pumps operation system

SPECIFICATIONSSTANDARD

Model UD2-S UD2-DLiquid handled property Fresh water, 0-40 dgree CInstallationOperation system

IndoorPump speed ConstantControl Controlled with pressure switch & flow switch*

AC, Three phase, 50Hz, 380VPower sourceMax. working pressureAllowabale suction pressure

6 to 10 barG (refer to model)Min. : -0.3bar, Max.: Refer to model

Pump operation No. 1 2Pump model CDX, 2CDX & 3M CMA,CDX, 2CDX & 3MControl panel

Pressure tank

Accessories

Starting methodConstructionOperation key

DOL(Up to 5.5kW) or Star-Delta(5.5 to 11kW)Dust proof typePush button & selector switch type Touch panel key type

ConstructionCapacity

Air precharged diaphragm typeRefer to model

OPTIONPump modelPressure tankInstallationOthers

Other modelsLarge capacityOutdoorOn request

Note) * In case of pump model CDX90/10 & CMA, flow switch is not provided.

MODEL UD2

40 50 60 70 80 100 200 300 400 500 600 700 800 1000

(80) (100) (120) (140) (160) (200) (400) (600) (800) (1000) (1200) (1400) (1600) (2000)

Unit Capacity (L/min)

1 Pump system2 Pumps system

1

2

3

4

5

6

7

8

10 9

Sup

ply

pres

sure

(kg/

cm2

G)

UNIT SELECTION CHART (Speed Approx. 2900min-1) Pump model

NORMAL PRESSURE BOOSTER UNIT

Control panel & support, Pressure switch, Flow switch*, Pressure tankPressure gauge, Common base, Piping & valves, Electrical wiring

Note : Models for pump CMA1.00 & CDX 90/10 are UD2-D (2 Pumps operation system)only.

CDX90/10CMA1.00

CDX120 /12

CDX120/20CDX200 /25CDX 200/20

2CDX120/15

2CDX120/20

2CDX120/30

2CDX200/50

2CDX200/402CDX200/30

3M32-160/2.2

3M32-200/43M32-160/3

3M32- 200/5.53M40-200/7.5

3M40-160/4

3M40-160/3

3M40-200/11

3M40-200/5.5

2CDX120/40