dx8ld—stratus multi-deck - kysor warren€™ 21.30 48.38 8’ 42.60 96.76 12’ 63.97 145.26...
TRANSCRIPT
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 7/15/2013DX8LD—STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4’ 21.30 48.38
8’ 42.60 96.76
12’ 63.97 145.26
Refrigeration Data
BTUH per FT of Case Unlighted Shelves
LED Lights
BTUH per FT of Case Unlighted Shelves
T8 LightsEvap. Temp.
Discharge Air
Parallel Single Parallel Single Temp Velocity
280 302 321 347 +28°F +34°F 185 FPM
BTUH determined using EC fan motors. Electrical Data
Length ECM Fan Data Light - Amps Anti-Sweat (Vista C)Fan Qty Amps Gelcore LED Optimax Pro Amps
4’ 1 0.10 0.28 0.16 0.85
8’ 2 0.20 0.53 0.33 1.13
12’ 4 0.40 0.82 0.48 1.96
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 1 45 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com
2178
1614
6
42
6758
88
AIR
SP
AC
E
3
4178
3478
292927
8
4234
16
30
70
48-1/8 (72-1/4)
42
43
29
24 (36)
712
24 (36)
18
512
96-1/4 (144-1/2)
ELECTRICAL ACCESS POINT
REFRIGERATION PENETRATION
DRAIN CONNECTION(WITH TRAP RIGHT OR LEFT)
FRONT OF CASE
29STUB UPAREA
STANDARD KICKPLATE LOCATION (PLATINUM)
3
3
3912
35
- STANDARD KICKPLATE LOCATION (MODERN, CLASSIC)- OPTIONAL KICKPLATE LOCATION (PLATINUM)
SKIDRAIL
3SKIDRAIL
MINIMUM AIR SPACE
LEG
LEG
LEG
LEG
312 7
3534
714
Add 3” thickness for a pair of ends.
DX8LD Cross View
DX8LD Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 12/6/2012DX8LN -- STRATUS Multi-Deck
Capacities
Length Facing Area (FT²) Cubic Capacity (FT³)4’ 21.4 53.66’ 32.1 80.48’ 42.8 107.212’ 64.2 160.8
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1161 1254 1167 1260 11 19 11 19 +26°F +33°F 225 FPMAdd 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps Per
Lighted Shelf
Nose Light - Amps
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row
LED2 Row
T84’ 1 0.14 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.28 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.28 0.12 0.25 0.2 0.5 0.48 1
12’ 4 0.56 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX8LN Cross View
Add 3” thickness for a pair of ends.
DX8LN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 6/21/2013DX8LN (Glycol) — STRATUS Multi-Deck
Capacities
Length Facing Area (FT²) Cubic Capacity (FT³)4’ 21.4 53.6
6’ 32.1 80.4
8’ 42.8 107.2
12’ 64.2 160.8
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1161 1254 1167 1260 11 19 11 19 +26°F +33°F 225 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps Per
Lighted Shelf
Nose Light - Amps
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row
LED2 Row
T84’ 1 0.14 0.12 0.25 0.1 0.25 0.24 0.5
6’ 2 0.28 0.09 0.22 0.18 0.44 0.37 0.88
8’ 2 0.28 0.12 0.25 0.2 0.5 0.48 1
12’ 4 0.56 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F
Glycol Data
Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 5,644 35 +20°F +10°F 1.447 2.0 PSI
6’ 8,466 35 +20°F +10°F 2.172 4.40 PSI
8’ 11,288 35 +20°F +10°F 2.895 2.0 PSI
12’ 16,935 35 +20°F +10°F 4.343 4.40 PSI
Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.
A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com
DX8LN Cross View
Add 3” thickness for a pair of ends.
DX8LN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 7/15/2013DX8UD—STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4’ 22.60 51.32
8’ 45.20 102.64
12’ 67.85 154.00
Refrigeration Data
BTUH per FT of Case Unlighted Shelves
LED Lights Evap. Temp. Discharge Air
Parallel Single Temp Velocity
300 325 +28°F +34°F 185 FPM
BTUH determined using EC Fan Motors. Electrical Data
Length ECM Fan Data Light - Amps Anti-Sweat
(Vista C)Fan Qty Amps Gelcore LED Optimax Pro Amps
4’ 1 0.10 0.16 0.16 0.85
8’ 2 0.20 0.28 0.33 1.13
12’ 4 0.40 0.42 0.48 1.96
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 3 45 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com
DX8UD Cross View
Add 3” thickness for a pair of ends.
DX8UD Plan View
48-1/8 (72-1/4)
42
43
29
24 (36)
712
24 (36)
18
512
96-1/4 (144-1/2)
ELECTRICAL ACCESS POINT
REFRIGERATION PENETRATION
DRAIN CONNECTION(WITH TRAP RIGHT OR LEFT)
FRONT OF CASE
29STUB UPAREA
STANDARD KICKPLATE LOCATION (PLATINUM)
3
3
3912
35
- STANDARD KICKPLATE LOCATION (MODERN, CLASSIC)- OPTIONAL KICKPLATE LOCATION (PLATINUM)
SKIDRAIL
3SKIDRAIL
MINIMUM AIR SPACE
LEG
LEG
LEG
LEG
312 7
3534
714
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX8UN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 21.4 53.66 32.1 80.48 42.8 107.212 64.2 160.75
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1300 1404 1306 1410 11 19 11 19 +26°F +33°F 200 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps
Per Lighted Shelf
Canopy Light - Amps
Fan Qty Amps LED T8 1 Row LED
2 Row T8
4’ 1 0.14 0.12 0.25 0.24 0.56’ 2 0.28 0.09 0.22 0.37 0.888’ 2 0.28 0.12 0.25 0.48 112’ 4 0.56 0.12 0.25 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX8UN Cross View
Add 3” thickness for a pair of ends.
DX8UN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 6/21/2013DX8UN (Glycol) — STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 21.4 53.6
6 32.1 80.4
8 42.8 107.2
12 64.2 160.75
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1300 1404 1306 1410 11 19 11 19 +26°F +33°F 200 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps
Per Lighted Shelf
Canopy Light - Amps
Fan Qty Amps LED T8 1 Row LED
2 Row T8
4’ 1 0.14 0.12 0.25 0.24 0.5
6’ 2 0.28 0.09 0.22 0.37 0.88
8’ 2 0.28 0.12 0.25 0.48 1
12’ 4 0.56 0.12 0.25 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F
Glycol Data
Length Heat Load – BTUH
Glycol % PG
Supply Temp (°F)
Temp Rise (°F)
Flow Rate (GPM)
Pressure Drop (PSI)
4’ 5,224 35 +20 +10 1.145 1.80
6’ 7,836 35 +20 +10 1.717 4.10
8’ 10,448 35 +20 +10 2.290 1.80
12’ 15,672 35 +20 +10 3.434 4.10
Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.
A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com
DX8UN Cross View
Add 3” thickness for a pair of ends.
DX8UN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 12/6/2012DX8XN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 20.4 53.66 30.6 80.48 40.8 107.212 61.2 160.8
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1085 1172 1091 1178 11 19 11 19 +26°F +33°F 225 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps Per
Lighted Shelf
Nose Light - Amps
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row
LED2 Row
T84’ 1 0.14 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.28 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.28 0.12 0.25 0.2 0.5 0.48 1
12’ 4 0.56 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX8XN Cross View
Add 3” thickness for a pair of ends.
DX8XN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 6/21/2013DX8XN (Glycol) — STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 20.4 53.6
6 30.6 80.4
8 40.8 107.2
12 61.2 160.8
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1085 1172 1091 1178 11 19 11 19 +26°F +33°F 225 FPM
Add 13 BTUH/FT for additional LED canopy light Electrical Data
Length ECM Fan Data
Shelf Light - Amps Per
Lighted Shelf
Nose Light - Amps
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row
LED2 Row
T84’ 1 0.14 0.12 0.25 0.1 0.25 0.24 0.5
6’ 2 0.28 0.09 0.22 0.18 0.44 0.37 0.88
8’ 2 0.28 0.12 0.25 0.2 0.5 0.48 1
12’ 4 0.56 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F
Glycol Data
Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 5,276 35 +20°F +10°F 1.353 1.90 PSI
6’ 7,914 35 +20°F +10°F 2.030 4.10 PSI
8’ 10,552 35 +20°F +10°F 2.705 1.90 PSI
12’ 15,828 35 +20°F +10°F 4.060 4.10 PSI
Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.
A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com
DX8XN Cross View
Add 3” thickness for a pair of ends.
DX8XN Plan View