dx7ld -- stratus multi-deck - kysor warren -- stratus multi-deck capacities length (ft) facing area...
TRANSCRIPT
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 12/6/2012DX7LD -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 21.30 48.388 42.60 96.7612 63.97 145.26
Refrigeration Data
BTUH per FT of Case Unlighted Shelves
LED Lights
BTUH per FT of Case Unlighted Shelves
T8 LightsEvap. Temp.
Discharge Air
Parallel Single Parallel Single Temp Velocity 280 302 321 347 +28°F +34°F 185 FPM
BTUH determined using EC fan motors.
Electrical Data
Length ECM Fan Data Light - Amps Anti-Sweat (Vista C)Fan Qty Amps T8 Gelcore LED Optimax Pro Amps
4’ 1 0.10 0.96 0.16 0.16 0.858’ 2 0.20 1.44 0.28 0.33 1.1312’ 4 0.40 1.82 0.42 0.48 1.96
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 3 45 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX7LD Cross View
Add 3” thickness for a pair of ends.
DX7LD Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 6/21/2013DX7LD (Glycol) — STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 21.3 48.38
8 42.6 96.76
12 63.97 145.26
Refrigeration Data
BTUH per FT of Case Unlighted Shelves
LED Lights
BTUH per FT of CaseUnlighted Shelves
*T8 LightsEvap. Temp. Discharge Air
Parallel Single *Parallel *Single Temp Velocity
280 302 *321 *347 +28°F +34°F 185 FPM
BTUH determined using EC fan motors.
Electrical Data
Length ECM Fan Data Light - Amps Anti-Sweat (Vista C)
Fan Qty Amps T8 Gelcore LED Optimax Pro Amps4’ 1 0.1 0.96 0.16 0.16 0.85
8’ 2 0.2 1.44 0.28 0.33 1.13
12’ 4 0.4 1.82 0.42 0.48 1.96
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 3 45 min +47°F
Glycol Data
Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 1,284 35 +20°F +12°F 0.234 0.40 PSI
8’ 2,578 35 +20°F +12°F 0.468 0.40 PSI
12’ 3,852 35 +20°F +12°F 0.704 0.80 PSI
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com
DX7LD Cross View
Add 3” thickness for a pair of ends.
DX7LD Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 12/6/2012DX7LN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 20.1 50.76 30.1 76.18 40.1 101.412 60.2 152.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1158 1251 1164 1257 11 19 11 19 +26°F +33°F 185 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps Per
Lighted Shelf
Nose Light - Amps
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row
LED2 Row
T84’ 1 0.1 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.2 0.12 0.25 0.2 0.5 0.48 112’ 4 0.4 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX7LN Cross View
Add 3” thickness for a pair of ends.
DX7LN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 6/21/2013DX7LN (Glycol) — STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 20.1 50.7
6 30.1 76.1
8 40.1 101.4
12 60.2 152.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1158 1251 1164 1257 11 19 11 19 +26°F +33°F 185 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps Per
Lighted Shelf
Nose Light - Amps
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row
LED2 Row
T84’ 1 0.1 0.12 0.25 0.1 0.25 0.24 0.5
6’ 2 0.2 0.09 0.22 0.18 0.44 0.37 0.88
8’ 2 0.2 0.12 0.25 0.2 0.5 0.48 1
12’ 4 0.4 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 35 min +47°F
Glycol Data
Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 5,132 35 +20°F +12°F 1.316 1.8 PSI
6’ 7,698 35 +20°F +12°F 1.974 4.0 PSI
8’ 10,263 35 +20°F +12°F 2.633 1.8 PSI
12’ 15,395 35 +20°F +12°F 3.948 4.0 PSI
Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.
A Proud Partner of: 5201 Transport Blvd. • Columbus, GA 31907Toll-Free: 800.866.5596 • Phone: 706.568.1514heatcraftrpd.com
DX7LN Cross View
Add 3” thickness for a pair of ends.
DX7LN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX7UD -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 21.3 48.388 42.6 96.76
12 63.97 145.26
Refrigeration Data
BTUH per FT of Case Unlighted Shelves
LED Lights
BTUH per FT of Case Unlighted Shelves
T8 Lights Evap. Temp. Discharge Air
Parallel Single Parallel Single Temp Velocity 280 302 321 347 +28°F +34°F 185 FPM
BTUH determined using EC Fan Motors.
Electrical Data
Length ECM Fan Data Light - Amps Anti-Sweat (Vista C)
Fan Qty Amps T8 Gelcore LED Optimax Pro Amps4’ 1 0.1 0.96 0.16 0.16 0.858’ 2 0.2 1.44 0.28 0.33 1.1312’ 4 0.4 1.82 0.42 0.48 1.96
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 3 45 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX7UD Cross View
Add 3” thickness for a pair of ends.
DX7UD Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX7UN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 21.02 50.76 31.48 76.18 41.99 101.412 62.96 152.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1193 1288 1199 1295 11 19 11 19 +26°F +33°F 185 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps
Per Lighted Shelf
Canopy Light - Amps
Fan Qty Amps LED T8 1 Row LED
2 Row T8
4’ 1 0.14 0.12 0.25 0.24 0.56’ 2 0.28 0.09 0.22 0.37 0.888’ 2 0.28 0.12 0.25 0.48 112’ 4 0.56 0.12 0.25 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX7UN Cross View
Add 3” thickness for a pair of ends.
DX7UN Plan View
DX7U
P - Multi-D
eck - Platinum
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 deg F and 55% relative humidity. Kysor/Warren, whose policy is one of continuous improve-ment, reserves the right to change at any time, specifications, design or prices without incurring obligation.
Defrost Per Day Fail Safe Termination
Off Cycle 6 18 min +47°F
Kysor/Warren 5201 Transport Blvd 800-866-5596 phone www.kysorwarren.com Columbus, GA 31907 706-568-8990 fax
Defrost Data
Electrical Data
All electrical data based on 115V and unlighted shelves.
Capacities Length Facing Area (FT²) Cubic Capacity (FT³)
8’ 38.3 101.4
12’ 57.4 152.2
6’ 28.7 76.1
4’ 19.1 50.7
Refrigeration Data
BTUH determined using EC Fan Motors. Add 13 BTUH/ft for additional LED canopy light.
BTUH per FT of Case Unlighted Shelves
One Row Canopy - LED Lights
BTUH per FT of Case Unlighted Shelves
One Row Canopy - T8 Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy Light
Evap. Temp. Parallel Single Parallel Single LED T8 LED T8 Temp Velocity
1082 1169 1088 1175 11 19 11 19 +26°F +33°F 185 FPM
Discharge Air
Length ECM Fan Data Shelf Light - Amps
Per Lighted Shelf Canopy Light - Amps
Fan Qty Amps LED T8 1 Row LED 2 Row T8
4’ 1 0.10 0.12 0.25 0.24 0.50
6’ 2 0.20 0.09 0.22 0.37 0.88
8’ 2 0.20 0.12 0.25 0.48 1.00
12’ 4 0.40 0.12 0.25 0.72 1.50
The above case model has case lengths that are UL and NSF approved. Issue: 1.30.2012
A proud partner of
DX7U
P - Multi-D
eck - Platinum
Add 3” thickness for a pair of ends.
Profile View
Floor Plan
FRONT OF CASE
STUB UPAREA
STANDARD KICKPLATE LOCATION
SKIDRAIL
SKIDRAIL
MINIMUM AIR SPACE
ELECTRICAL - TOP LEFT REAR REFRIGERATION PENETRATION
TOP
REAR
1-1/2 PVC DRAIN PRE-PIPED TO FRONT
ELECTRICAL ACCESS BOX
MIN
IMU
M A
IR S
PA
CE
4036
2
283
4234
1-1/2" PVCCONDENSATE DRAINS
112
4234
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX7XN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.1 50.76 28.7 76.18 38.3 101.412 57.4 152.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1082 1169 1088 1175 11 19 11 19 +26°F +33°F 185 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps Per
Lighted Shelf
Nose Light - Amps
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row
LED2 Row
T84’ 1 0.1 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.2 0.12 0.25 0.2 0.5 0.48 112’ 4 0.4 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Glycol Data
Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 4,796 35 +20°F +12°F 1.024 1.4 PSI6’ 7,194 35 +20°F +12°F 1.537 3.0 PSI8’ 9,592 35 +20°F +12°F 2.049 1.4 PSI12’ 14,388 35 +20°F +12°F 3.047 3.0 PSI
Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX7XN Cross View
Add 3” thickness for a pair of ends.
DX7XN Plan View
The above case model has case lengths that are UL and NSF approved.
Merchandising Applications
Issue Date: 11/14/2012DX7XN -- STRATUS Multi-Deck
Capacities
Length (FT) Facing Area (FT²) Cubic Capacity (FT³)4 19.1 50.76 28.7 76.18 38.3 101.412 57.4 152.2
Refrigeration Data
BTUH per FT of Case
Unlighted Shelves One Row Canopy -
LED Lights
BTUH per FT of Case
Unlighted Shelves One Row Canopy - T8
Lights
Add BTUH per FT per Row
Lighted Shelves
Add BTUH per FT per Row
Nose Lights or Additional T8 Canopy
Light
Evap. Temp.
Discharge Air
Parallel Single Parallel Single LED T8 LED T8 Temp Velocity 1082 1169 1088 1175 11 19 11 19 +26°F +33°F 185 FPM
Add 13 BTUH/FT for additional LED canopy light
Electrical Data
Length ECM Fan Data
Shelf Light - Amps Per
Lighted Shelf
Nose Light - Amps
Canopy Light - Amps
Fan Qty Amps LED T8 LED T8 1 Row
LED2 Row
T84’ 1 0.1 0.12 0.25 0.1 0.25 0.24 0.56’ 2 0.2 0.09 0.22 0.18 0.44 0.37 0.888’ 2 0.2 0.12 0.25 0.2 0.5 0.48 112’ 4 0.4 0.12 0.25 0.36 0.75 0.72 1.5
Defrost Data
Defrost Per Day Fail Safe TerminationOff Cycle 6 18 min +47°F
Glycol Data
Length Heat Load-BTUH Glycol % PG Supply Temp Temp Rise Flow Rate (GPM) Pressure Drop4’ 4,796 35 +20°F +12°F 1.024 1.4 PSI6’ 7,194 35 +20°F +12°F 1.537 3.0 PSI8’ 9,592 35 +20°F +12°F 2.049 1.4 PSI12’ 14,388 35 +20°F +12°F 3.047 3.0 PSI
Type I refrigerator, intended for use in an area where the environ-mental conditions are controlled and main-tained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Re-frigeration, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices with-out incurring obligation.
A Proud Partner of:
5201 Transport Blvd. · Columbus, GA 31907P: 800.866.5596 · F: 706.568.8990heatcraftrpd.com
DX7XN Cross View
Add 3” thickness for a pair of ends.
DX7XN Plan View