  • 8/12/2019 Durag Dust Monitor

    1/13

    D-R 290

    Dust and OpacityMonitor

  • 8/12/2019 Durag Dust Monitor

    2/13

    Seite 2

    D-R 290 Dust and Opacity Monitor

  • 8/12/2019 Durag Dust Monitor

    3/13

    Seite 3

    Specifications of D-R 290

    Measuring range 0-200 / 4000 mg/m 3 per meter

    Light source Super wide band diode SWBDOptical density 0.1 - 1.6 optical density (Ext)

    Opacity 20 - 100 %, stack exit correction

    Length of measuring path 1 - 12 m, only two reflectors

    Bus interface optionally ModbusOutput signal 2 x 0-20 mA, 4mA Zero

    Range switching external and automatic (optional)

    Relay input/outputs 6 x status, potential free

    Integration time 5 1800 secondsAmbient temperature -20 - +50 C

    Mains 95-264 V, 48-62 Hz, 30 W (Monitor)115/230V, 50/60 Hz, 400 W (Fan)

  • 8/12/2019 Durag Dust Monitor

    4/13

    Seite 4

    D R 290 System Components

    D-R 290 AW

    Optical Measuring Unit Reflector Unit

    Evaluation UnitPurge Air Fan

    Reflector 1: 1 2.25 m

    Reflector 2: 1.75-12 m(special execution:

  • 8/12/2019 Durag Dust Monitor

    5/13

    Seite 5

    System Components

    1. Evaluation Unit

    2. Measuring Head

    3. Reflector

    4. Adjuster Flange

    5. Purge Air Fan

    6. Recorder

    7. Weather HoodsHead&Reflector

    8. Weather HoodBlower

    9. Fail Safe Shutter

    10. Control Unit forShutter

  • 8/12/2019 Durag Dust Monitor

    6/13

    Seite 6

    D-R 290 Control Panel

    Display of- mA

    - Opacity

    - Optical Density

    - mg/m 3

    Easy to operate

    No computer required forset-up

    Data entry by four keymenu

    OUTPUT 1 00:01

    Op 85.5 17.68mA

  • 8/12/2019 Durag Dust Monitor

    7/13

    Seite 7

    Easy 4-key Operating

    LED LED

    MOD STO

    Display measured values

    Display parameters

    Undo data modification

    Data entry

    Store data

    Select measured data from channel 1 / 2

    Select parameter

    Increase digit value

    Select digit / move cursor

    STO

    MOD

    +

    STO MOD +

  • 8/12/2019 Durag Dust Monitor

    8/13

    Seite 8

    D-R 290 On-Stack and Remote Control Unit

    Standard: On-Stack Display

    Optional: Remote Control

    Housing: Wall (IP68) or Rack Mounting

    2 ... max. 10 m

    2 ... max. 10 m max. 1000 m

    Evaluation Unit

    Display Unit Evaluation Unit

    mA

    OptionMODBUS

    mA

    OptionMODBUS

  • 8/12/2019 Durag Dust Monitor

    9/13

    Seite 9

    D-R 290 Dust Concentration and Opacity Monitor

  • 8/12/2019 Durag Dust Monitor

    10/13

    Seite 10

    Main Board Measuring Head

    S1 = Watch dog timer

    S2 = Enable S6

    S3 = Enable S4

    S4/1 = Output slope

    S4/2 = Control mode slope

    S4/3 = Span slope

    S4/4 = Offset Zero intern

    S4/5 = Offset Zero extern

    S4/6 = Basic adjust locked

    S5 = Data entry enable

    S6 = Service switch

    S7 = IncreaseS8 = Decrease

    S9 = TemperatureCompensation (optional)

    P1 = Offset setting

    1 2 3 4 5 6

    OFF

    P1S5 S8 S7 S4 S1

    S6 S2

    D-R 290 MK No 21

    gelb

    yellow

    rot

    red

    Abgleich Adjustment

    Speichern FreigabeStorage release

    on

    off

    on

    off

    S3

    Speichern FreigabeStorage release

    Abgleich Adjustment

    gesperrt

    locked 1 2 3 4 5 6 7 8

    OFF

    S9

    d r w

    _ r 2

    9 0

    _ 0 2 3

    _ 0 2

    _ M K N o

    2 1

  • 8/12/2019 Durag Dust Monitor

    11/13

    Seite 11

    Customer length Calibration

    Mount instrument on calibration flanges in a dust-free environment, at theexact distance as measuring path length and power on.

    Set switch S2/S3 up, check the optical alignment & make it perfect & setS2/S3 down.

    Press switch S5 towards left. The yellow LED starts blinking & system will automatically start calibration

    cycle.- LED Int. CALIB- Zero point INTERNAL calibration.- Span calibration- Zero point EXTERNAL calibration- Zero point check- Window check

    - Span check

    Normal operation Manually fine adjustment S2 / S3 , S4|4 (int), S4|5 (ext) & S7&S8

  • 8/12/2019 Durag Dust Monitor

    12/13

    Seite 12

    Error Messages

    data transfer Err 000 R6 R5 contamination exceeded Err 001 R5

    message external 1 AW Err 002 R5 message external 2 AW Err 003 R5 EEPROM Err 004 R5 RAM Err 005 R6 R5 PROM Err 006 R6 R5 AW-System Err 007 R6 R5 comparison Err 010 R5 R5= Error

    zero point external Err 020 R5 zero point internal Err 030 R5 R6= System fault stepper motor Err 040 R6 R5 LED Error Err 050 R6 R5 heated window Err 060 R5 optic head Err 070 R6 R5 message input 1 AZ Err 100 R5 message input 2 AZ Err 200 R5 message input 3 AZ Err 300 R5 message input 4 AZ Err 400 R5 message input 5 AZ Err 500 R5 message input 6 AZ Err 600 R5 AZ-System Err 700 R6 R5

  • 8/12/2019 Durag Dust Monitor

    13/13

    Maintenance Works:

    Cleaning of optical lenses Cleaning of blower filters

    Cleaning of External parts Check the alignment of the instrument

    Seite 13