dubis2020 physiological opticscvrl.ucl.ac.uk/neur0017/lecture notes/dubis/dubis physiological...

78
Physiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January 2020 NEUR 0017 Visual Neuroscience

Upload: others

Post on 10-Jun-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Physiological Optics and the Photoreceptor Mosaic

Adam M Dubis, PhD

14 January 2020

NEUR 0017Visual

Neuroscience

Page 2: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Outline

o The eyeo Visual opticso Image qualityo Measuring image qualityo What limits visual performance?o Refractive errorso Samplingo Why visual acuity should be limited by the optics and

samplingo Adaptive opticso Chromatic aberrations

Page 3: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

The retina is carpeted with light-sensitive rods and cones

An inverted image is formed on the retina by the cornea and lens.

Page 4: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Cornea – Clearmembrane on the front ofthe eye.Crystalline Lens –Lens thatcan change shape toalter focus.Retina – Photosensitiveinner lining of eyeFovea – central region ofretina with sharpestvision.Optic Nerve – bundle ofnerve fibers that carryinformation to the brain.

Jim Schwiegerling

Page 5: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Amar Gajakosh – Help 4 Students

Eye Dissection and Part of the Eye

Page 6: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Visual optics

Page 7: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Borrowed from Jim Schwiegerling

Cornea Crystalline Lens

Heidelberg Engineering

Leitgeb Laboratory

Page 8: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Retinal cross-section

Retina 200 ´LIGHT

Page 9: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Accommodation to Target Distance

Distant target, relaxed ciliary muscles

Near target, accommodated eye, constricted ciliary muscles.

Larry Thibos

Page 10: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Jim Schwiegerling

Relaxed ciliary muscle pulls zonules taut an flattens crystalline lens.

Constricted ciliary muscle releases tension on zonules and crystalline lens bulges.

Accommodation

Page 11: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Presbyopia (age related far-sightedness)

Page 12: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

From Webvision, Michael Kalloniatis

Nearsighted

Farsighted

PSFs for different refractive errors

Page 13: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Corrective lenses

Myopia Hyperopia

Page 14: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Focalplane

Light

Lens

Emmetropia(normal)

Myopia(nearsightedness)

Hyperopia(farsightedness)

Presbyopia(aged)

Page 15: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Retinal Sampling and Resolution

Page 16: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Imaging Resolution

Sensor

Object

ImagingBeam

Poor Optical Resolution

Poor Sensor Resolution

Good Optical and Sensor Resolution

Page 17: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

The Point Spread Function (PSF) characterizes the optical performance of the eye.

Page 18: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

18

Point Spread Function Shapevs Resolution

Page 19: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Point Spread

FunctionOpticalSystemscene image

( )xd ( )xPSFOpticalSystempoint source point spread function

Optical systems are rarely ideal.

Point spread function of Human Eyes

PSFInput

Page 20: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

From Webvision, Michael Kalloniatis

Point in visual space

Point spread function (PSF)

Page 21: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Measuring Image Quality Psychophysically

1. Visual acuity measures- Review methods for measurement in the clinic/trial setting- What do these measures represent

2. Spatial contrast sensitivity measures- Review methods for measurement in the clinic/trial setting- How does this represent our vision

Page 22: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

6/60

6/30

6/21

6/15

6/126/9

6/7.56/6

Smallest resolvable black and whitetarget. Many different types oftests are available , but the letter chart introduced by Snellen in 1862 is the most common.

Page 23: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

6/60

6/30

6/21

6/15

6/126/9

6/7.56/6

Snellen defined “standard vision” as the ability to recognize one of his optotypes when it subtended 5 minutes of arc. Thus, the optotypecan only be recognized if the person viewing it can discriminate a spatial pattern separated by a visual angle of 1 minute of arc.

A Snellen chart is placed at a standard distance, twenty feet in the US (6 metres in Europe). At this distance, the symbols on the line representing "normal" acuity subtend an angle of five minutes of arc, and the thickness of the lines and of the spaces between the lines subtends one minute of arc. This line, designated 20/20, is the smallest line that a person with normal acuity can read at a distance of twenty feet.

The letters on the 20/40 line are twice as large. A person with normal acuity could be expected to read these letters at a distance of forty feet. This line is designated by the ratio 20/40. If this is the smallest line a person can read, the person's acuity is "20/40."

NORMALACUITY

Page 24: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Visual Acuity: four standard methods

Letter acuity

(Snellen)

Grating acuity

2-line resolution

2-point resolution

vs.

vs.

Orientation resolution acuity

Detection acuity

Borrowed from Arthur Bradley

Can the subject correctly identify the letter or the letter orientation?

Can the subject see two lines or points rather than one?

Page 25: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

25

MAR

MAR = Minimum Angle of Resolution

MAR is the smallest gap between letter strokes or grating bars that can be detected/resolved.

6/6 (20/20) letter: bar/stroke width = 1 arc minute, letter height = 5 min Grating period = 2 arc minute (1/30 degree) when bar = 1 min, and grating SF = 1/period = 30 c/deg,

{One period or cycle

Arthur Bradley

Page 26: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Snellen Metric Snellen

MAR in arc minutes Log MAR Decimal Grating VA

c/deg

20/10 6/3 0.5 -0.3 2.0 60

20/15 6/4.5 0.75 -.12 1.33 40

20/20 6/6 1 0.0 1.0 30

20/25 6/7.5 1.25 0.1 0.8 24

20/30 6/9 1.5 0.18 0.7 21

20/40 6/12 2 0.3 0.5 15

20/50 6/15 2.5 0.4 0.4 12

20/70 6/21 3.5 0.54 0.3 9

20/100 6/30 5 0.7 0.2 6

20/200 6/60 10 1.0 0.1 3

Comparison of seven different visual acuity measures

Arthur Bradley

NORMALACUITY

Page 27: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

logM

AR

Log Retinal Illuminance (Trolands)

6/60

6/6

Rod vision

logM

AR

Retinal Eccentricity (degrees)

6/60

6/6

Scotopic

0 30

Photopic

Vision is not always 6/6!

Light Level

Eccentricity

Arthur Bradley

Page 28: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Measuring Image Quality Psychophysically

1. Visual acuity measures- Review methods for measurement in the clinic/trial setting- What do these measures represent

2. Spatial contrast sensitivity measures- Review methods for measurement in the clinic/trial setting- How does this represent our vision

Page 29: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Image of line

PSF

Spatial MTF

What would the results for a perfect lens look like?

Page 30: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Source: Hans Irtel

Incr

easi

ng s

patia

l fre

quen

cy

Increasing contrast

Spatial Frequency Gratings

Page 31: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Spatial MTFSpatial frequency in this image increases in the horizontal direction and modulation depth decreases in the vertical direction.

Increasing spatial frequency

Incr

easi

ng c

ontra

st

Page 32: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Spatial MTF

Increasing spatial frequency

Incr

easi

ng c

ontra

stThe apparent border between visible and invisible modulation corresponds to your own visual modulation transfer function.

Page 33: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

low highmediumSpatial Frequency (c/deg)

Cont

rast

Sen

sitiv

ity

(1/c

ontra

st th

resh

old)

Peak CS

Peak SFHigh SFcut-off

Contrast Sensitivity Function (CSF)2. Grating Contrast Sensitivity

Arthur Bradley

“Bandpass”

Page 34: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Example of grating contrast sensitivity test using printed gratingsIn

crea

sing

spa

tial f

requ

ency

Increasing contrast sensitivity

Increasing contrast

Arthur Bradley

Page 35: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

What happens as the visual system light adapts?

Spatial CSFs

Page 36: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Light Level

PhotopicMesopic

Scotopic

20/200 20/15

Eccentricity

Foveal4deg

30deg

Contrast sensitivity varies!

Arthur Bradley

Page 37: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

What limits visual performance?

Page 38: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Imaging Resolution

Sensor

Object

ImagingBeam

Poor Optical Resolution

Poor Sensor Resolution

Good Optical and Sensor Resolution

Page 39: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Optical Image on Retina

Neural Retina Cortex Perception

Stages

Arthur Bradley

Page 40: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Optical Image on Retina

Stages

Arthur Bradley

Consider optical limits first

Page 41: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

From Webvision, Michael Kalloniatis

For a diffraction-limited image an Airy disk pattern is formed on the retina from a point source due to the diffraction at the pupil.

Airy disc (PSF)

Perception

2D profile

Page 42: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

From Webvision, Michael Kalloniatis

How does this affect spatial resolution?

Airy disc (PSF)

Perception

2D profile

Page 43: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

From Webvision, Michael Kalloniatis

Two points in visual space

Overlapping point spread functions (PSF)

Page 44: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

The Rayleigh criterion for resolving two point sources of equal brightness is when the peak of one diffraction pattern lies upon the first minimum of the other. This yields a theoretical maximum angular resolution referred to as diffraction-limited resolution given by:

where Δθ is in radians, D is the diameter of the aperture (i.e. the pupil in this case) in the same units as the wavelength λ of the light.

Two points in visual space

From Webvision,Michael Kalloniatis

Light intensity profile (PSF) at the back of the eye produced by the points

Page 45: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

So, for a 550 nm light and a 3 mm diameter pupil, Δθ = 0.77 min of arc.

Two points in visual space

Light intensity profile (PSF) at the back of the eye produced by the points

Page 46: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

From Webvision, Michael Kalloniatis

Two lines in visual space

The two lines (a) can be perceptually resolved, but the two lines (b) cannot and are perceived as a single line.

Line spread functions at the back of the eye

Page 47: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Snellen Metric Snellen

MAR in arc

minutes

LogMAR Decimal Grating VA c/deg

JaegerNear VA

20/10 6/3 0.5 -0.3 2.0 60 NA20/15 6/4.5 0.75 -.12 1.33 40 NA20/20 6/6 1 0.0 1.0 30 J1+20/25 6/7.5 1.25 0.1 0.8 24 J120/30 6/9 1.5 0.18 0.7 21 J220/40 6/12 2 0.3 0.5 15 J320/50 6/15 2.5 0.4 0.4 12 J520/70 6/21 3.5 0.54 0.3 9 J7

20/100 6/30 5 0.7 0.2 6 J1020/200 6/60 10 1.0 0.1 3 J16

Comparison of seven different visual acuity measures

Arthur Bradley

DIFFRACTIONLIMIT

Page 48: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

The size of the pupil is an important factor affecting visual acuity.

A large pupil allows more light to reach the retina and reduces diffraction but resolution is reduced because the optical aberrations are greater (a greater area of the lens and cornea are used and they are imperfect).

A small pupil reduces optical aberrations but resolution is then diffraction limited.

A mid-size pupil of about 3 mm to 5 mm represents a compromise between the diffraction and aberration limits

Effect of Aperture: Pupil size

Page 49: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Aberrations of the Eye

Perfect optics Imperfect optics

Larry Thibos

Page 50: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

50

Removing Atmospheric Blur….Adaptive Optical Systems

Page 51: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Wave Aberration

(High order)

Perfect eye(diffraction-limited) MRB GYY MAK

5.7-mm pupil

Courtesy: Jason Porter

The Human Eye is Highly Aberrated

Page 52: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

The Human Eye is Highly Aberrated

Ideal, Diffraction-Limited Eye

Normal, Aberrated Eye

Lenslet Array

CCD Array

Spot Array Wave Aberration

f

Dd

Page 53: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Principle of Adaptive Optics Retinal Imaging

J. Carroll, D. Gray, A. Roorda, D. R. Williams (2005)

Page 54: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Principle of Adaptive Optics Retinal Imaging

J. Carroll, D. Gray, A. Roorda, D. R. Williams (2005)

Page 55: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January
Page 56: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January
Page 57: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January
Page 58: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January
Page 59: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Cone Inputs and Visual Sensation

Page 60: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Cone Stimulation Map

Page 61: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Chromatic aberrations

Page 62: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Base picture: Digital camera world

Chromatic aberration

Page 63: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Effect of chromatic blur on eye chart

Jim Schwiegerling

Page 64: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Ray Tracing: Light to Image

64

Sensor/Camera

EyeOphthalmoscope

Page 65: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Ray Tracing: Light to Image

65

Sensor/Camera

EyeOphthalmoscope

Page 66: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Ray Tracing: Light to Image

66

Sensor/Camera

EyeOphthalmoscope

Page 67: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Ray Tracing: Light to Image

67

Sensor/Camera

EyeOphthalmoscope

Page 68: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Ray Tracing: Light to Image

68

Sensor/Camera

EyeOphthalmoscope

Page 69: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Changes with eccentricity

Page 70: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

logM

AR

Retinal Eccentricity (degrees)

6/60

6/6

Scotopic

0 30

Photopic

Eccentricity

Arthur Bradley

Page 71: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Human photoreceptors

Rods§ Achromatic

night vision§ 1 type

Short-wavelength-sensitive (S) or “blue” cone

Middle-wavelength-sensitive (M) or “green” cone

Long-wavelength-sensitive (L) or “red” cone

Cones§ Daytime, achromatic

and chromatic vision§ 3 types

Rod

Page 72: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

0.3 mm of eccentricity is about 1 deg of visual angle

Rod and cone distribution

Page 73: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Cone distribution and photoreceptor mosaics

Page 74: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Roorda et al., 2001

Primate retina

Page 75: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Credit: Stuart Anstis, UCSD

Original photograph

Simulation of what we see when we fixate with cone vision.

The human visual system is a foveating system

Page 76: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Credit: Stuart Anstis, UCSD

Visual acuity gets much poorer with

eccentricity

Page 77: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

Conclusions• Light can function as both a particle and a wave, these are

important properties to understand how light interacts with the environment to permit vision

• Light passes through the cornea, where refractive index changes cause aberrated focusing

• Fixation is dependent on a cone rich foveal region that provides high acuity and colour vision, outside this region is rod rich, very light sensitive but lacks acuity or colourdiscrimination

Page 78: Dubis2020 Physiological opticscvrl.ucl.ac.uk/neur0017/Lecture Notes/Dubis/Dubis physiological optics.pdfPhysiological Optics and the Photoreceptor Mosaic Adam M Dubis, PhD 14 January

78

Interested in learning more?

[email protected]