Bluetooth controllable, Casambi enabled, 4 input 4 output interface, with feedback led and multivoltage power supply. It can be
connected, only by qualified professionals. Can be controlled via PLH Aria keypads, and with Casambi app available for iOs (iPhone 4S
or later, iPad 3 or later, iPod Touch 5th gen or later) and Android devices (Android 4.4 KitKat or later devices produced after 2013 with
full Bluetooth 4.0 support).
Drawings and measures
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Technical specifications
Electrical input specs Voltage range and frequency AC | DC: Input Dry contact
Output Transistor
Feedback Led
Radio transceiver Maximum output power: Ambient temperature, ta: Max. case temperature, tc: Max. relative humidity: Range (depending on the surrondings)
Wiring Wire range, solid & stranded:
Mechanical data Dimensions:Weight:Degree of protection:
90 - 250V (0,5 VA) | 12-30V DC (1W)
4 NO to ground and pass through
4 (100mA and 30V DC max); open-collector to ground; control of inductive load allowed (with relays)
white (output) and blue (input) on board
2,4...2,483 Ghz +4 dBm -20...+45 °C +65 °C 0...80%, non-cond. up to 15 m
interface si provided with precutted 5 cm wires 0,5 mm2 16 AWG
50,0 x 50,0 x 40,0 mm 50 gIP67
Firmware: 5081 Output: 4 Switch (relais bistable) - 0 Push button (relais monostable) Input: 4 dry contact
5082 Output: 3 Switch (relais bistable) - 1 Push button (relais monostable) Input: 4 dry contact
5083 Output: 2 Switch (relais bistable) - 2 Push button (relais monostable) Input: 4 dry contact
5084 Output: 1 Switch (relais bistable) - 3 Push button (relais monostable) Input: 4 dry contact
5085 Output: 0 Switch (relais bistable) - 4 Push button (relais monostable) Input: 4 dry contact
5975 Output: 4 Pwm Input: 4 dry contact
� �
Installation Make sure that the mains voltage is switched off when making any connections. Use right connectors or seal butt slice to join the jellyfish interface to the
electric wires of the plant.. If you install the interface into a heat sensitive environment (i.e. inside a luminaire or in a ceiling outlet box above a luminaire), make sure that the ambient temperature does not exceed the specified maximum value.
Wiring
Insulate the not used wires. Use the right connectors for the connections, not included, like Perma-Seal Butt Slice (Molex 19164-0013) or Wago 221, 243 or 2273 series.
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
Input 1 2aInput 2 2bInput 3 2cInput 4 2d
Common (-) 2e
Common (-) 3aOutput 4 3bOutput 3 3cOutput 2 3dOutput 1 3e
Common (+) 3f
4a Common (-)4b Input 44c Input 34d Input 24e Input 1
90-250V AC Neutral 1a90-250V AC Phase 1b
6a Max 30V DC (+)6b Max 30V DC (-)
Perma-Seal Butt Slice Molex
Wago 221
� �
Example 1: connection with BUS dry contact interface Gira 1119 00 Konnex interface In this solution you can control directly, using a PLH Aria keypad or a smartphone, a KNX bus system via a bus dry contact interface. Power supply need to be
granted (230V AC or maximum 30V DC using the right wires) Refer to Gira Interface specification document for any further information http://download.gira.com/data3/11193290.pdf Firmware 5085 PLH Jellyfish
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
- +
A1/E1
A2/E2 E3 E4
com
GN RD YE PK GY
90-250V AC Neutral 1a90-250V AC Phase 1b
6a Max 30V DC (+)6b Max 30V DC (-)
KNX Bus
� �
Example 2: connection with BUS dry contact interface Philips LCU2070 DALI interface In this solution you can control directly, using a PLH Aria keypad or a smartphone, a Dali bus system via a bus dry contact interface. Power supply need to be
granted (230V AC or maximum 30V DC using the right wires) Refer to Philips Interface specification document for any further information http://www.assets.lighting.philips.com/is/content/PhilipsLighting/a7f5741c4ff54b2c90e4a68f00b8c881 Firmware 5085 PLH Jellyfish
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
90-250V AC Neutral 1a90-250V AC Phase 1b
6a Max 30V DC (+)6b Max 30V DC (-)
LCU2070/009137 003 35103Made in E.U.PFT yyww
DA+DA-123456
DALI Bus
� �
Example 3: connection with BUS dry contact interface C2N-UNI8IO Crestron interface In this solution you can control directly, using a PLH Aria keypad or a smartphone, a Cresnet bus system via a dry contact interface. Power supply need to be
granted (230V AC or maximum 30V DC using the right wires) Refer to Crestron Interface specification document for any further information https://www.crestron.com/getmedia/41ce847e-5535-492f-a1df-298812b77537/ss_c2n-uni8io_1 Firmware 5085 PLH Jellyfish
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
OUTPU
T INPUT
GG12345678
5V1234567824V
90-250V AC Neutral 1a90-250V AC Phase 1b
6a Max 30V DC (+)6b Max 30V DC (-)
Cresnet Bus
� �
Example 4: connection with BUS dry contact interface QSE-CI-WCI Lutron interface In this solution you can control directly, using a PLH Aria keypad or a smartphone, a Lutron bus system via a dry contact interface. Power supply need to be
granted (230V AC or maximum 30V DC using the right wires) Refer to Lutron Interface specification document for any further information http://www.lutron.com/TechnicalDocumentLibrary/369681a.pdf Firmware 5085 PLH Jellyfish
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
90-250V AC Neutral 1a90-250V AC Phase 1b
6a Max 30V DC (+)6b Max 30V DC (-)
QS
LIN
K w
irin
g 12345678
LEDs
Contact Closure Inputs2(Orange)
3(Yellow)
4(Green)
5(Blue)
6(Purple)
7(Gray)
8 9(Black)
1(Red)
� �
Example 5: connection with relays bistable In this solution you can control directly, using a PLH Aria keypad or a smartphone or a local normally open push buttons (4 in this scheme), relays with coil in
extra low tension and contact in 230V (for example Finder 46 series) and 24 V leds. Power supply need to be granted (230V AC or maximum 30V DC using the right wires) Firmware 5083
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
Finder 46 series
k1 k2
230V AC Phase
230V AC Neutral
load 230V
load 230V
230V AC Neutral 1a230V AC Phase 1b
6a 24V DC (+)6b 24V DC (-)
k1 k2
� �
Example 6: control of curtains In this solution you can control 2 curtain in 230V AC directly, using a PLH Aria keypad or a smartphone or a local normally open push buttons (4 in this
scheme), relays with mechanical interlock with coil in extra low tension and contact in 230V. Power supply need to be granted (230V AC or maximum 30V DC using the right wires) Firmware 5085
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
230V AC Neutral 1a230V AC Phase 1b
6a 24V DC (+)6b 24V DC (-)
k3 down k4 upk1 down k2 up
Finder 46 series
k1
230V AC Phase
230V AC Neutral
M1
UP DOWN
k236 36
5 7 4 2 5 7 4 2
k3
M1
UP DOWN
k436 36
5 7 4 2 5 7 4 2
� �
Example7: control of single channel D-PWM ballast In this solution you can control, using a PLH Aria keypad or a smartphone, a PWM dimmer led. Power supply need to be granted (230V AC or maximum 30V
DC using the right wires) Refer to Dalcnet specification document for any further information http://www.dalcnet.com/wp-content/uploads/DLA1248_1CH_ita.pdf Firmware 5975 PLH Jellyfish
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
90-250V AC Neutral 1a90-250V AC Phase 1b
6a Max 30V DC (+)6b Max 30V DC (-)
DC In 12-48V DC (+)DC In 12-48V DC (-)
LED
� �
Example8: control of multi channel D-PWM ballast In this solution you can control, using a PLH Aria keypad or a smartphone, a PWM multi dimmer led. Power supply need to be granted (230V AC or maximum
30V DC using the right wires) Refer to Dalcnet specification document for any further information http://www.dalcnet.com/wp-content/uploads/DLA1224_4CH_ita.pdf Firmware 5975 PLH Jellyfish
© 2017 - epic srl - All rights reserved - Subject to technical change - Check periodically the website Doc. DS_A.JF rev. 1.0
Warning!
Hazardous voltages. Risk of electric shock or fire. Only qualified professionals should make the
connections in accordance with the local regulations and rules. Disconnect the mains power
supply and verify its absence prior to installation.
!
90-250V AC Neutral 1a90-250V AC Phase 1b
6a Max 30V DC (+)6b Max 30V DC (-)
LEDBOOSTER
12-24V DC (+)12-24V DC (-) SINGLE COLOR LED
IN PWM
DC IN OUT
TUNEBLE WHITE
RGBW
RGB