5
Insulation Class:....................................................................................................................F2 WARNING: Not suitable for pumping flammable or combustible liquids or use in a hazardous duty environment. DATA-280P-05-17 Technical Specifications Enclosure: ...........................................................................................Open Drip Proof (IP44) Available Voltage: .................................................................SP-280P & SP-280P-V : 110V Horsepower (Watts):...............................................................................................1.1 (825) Phase:.................................................................................................................................1 Amps:.............................................................................................2.5 - 8 (varies by voltage) Frequency: .............................................................................................................50-60 Hz Certification:.....................................................................................ETL (110V) or CE (220V) Housing Material:...................................................................Thermoplastic Polyester Resin Power Cord Length:..........................................................................................16 ft. (4,8 m) Power Cord Plug Type:..............................................NEMA 5-15-P (110V) or CEE 7/7 (220V) Noise Level:...............................................................................................................84 dBa Low Voltage Release:.........................................................SP-280P-2 & SP-280P-2-V : Yes Thermal Overload:..........................................................................................................Yes Variable Speed:.....................................SP-280P-V, SP-280P-2-V, & SP-280P-2-VNL : Yes Drum Pump Motors | SP-280P Series Weight:............................................................................................................10 lbs (4,5 kg) .................................................SP-280P, SP-280P-V, SP-280P-2NL & SP-280P-2-VNL : No ...........................................................................SP-280P, SP-280P-2 & SP-280P-2NL : No ....................................SP-280P-2, SP-280P-2-V, SP-280P-2-NL & SP-280P-2-VNL : 220V Note: Not recommended for use with the SP-700SR or 800SR Series pump.

Upload: others

Post on 05-Jan-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Drum Pump Motors SP-280P Series - AIQSA

Insulation Class:....................................................................................................................F2

WARNING: Not suitable for pumping flammable or combustible liquids or use in a hazardous duty environment.

DATA-280P-05-17

PSI (BAR) FT (M)

GPM(LPM)

5 4

6

PSI (BAR) FT (M)

GPM(LPM)

13

2

Technical Specifications

Enclosure: ...........................................................................................Open Drip Proof (IP44)Available Voltage: .................................................................SP-280P & SP-280P-V : 110V

Horsepower (Watts):...............................................................................................1.1 (825)

Phase:.................................................................................................................................1Amps:.............................................................................................2.5 - 8 (varies by voltage)Frequency: .............................................................................................................50-60 Hz

Certification:.....................................................................................ETL (110V) or CE (220V)Housing Material:...................................................................Thermoplastic Polyester Resin

Power Cord Length:..........................................................................................16 ft. (4,8 m)

Power Cord Plug Type:..............................................NEMA 5-15-P (110V) or CEE 7/7 (220V)Noise Level:...............................................................................................................84 dBaLow Voltage Release:.........................................................SP-280P-2 & SP-280P-2-V : Yes

Thermal Overload:..........................................................................................................Yes

Variable Speed:.....................................SP-280P-V, SP-280P-2-V, & SP-280P-2-VNL : Yes

Drum Pump Motors | SP-280P Series

Weight:............................................................................................................10 lbs (4,5 kg)

.................................................SP-280P, SP-280P-V, SP-280P-2NL & SP-280P-2-VNL : No

...........................................................................SP-280P, SP-280P-2 & SP-280P-2NL : No

....................................SP-280P-2, SP-280P-2-V, SP-280P-2-NL & SP-280P-2-VNL : 220V

Note: Not recommended for use with the SP-700SR or 800SR Series pump.

Page 2: Drum Pump Motors SP-280P Series - AIQSA

Insulation Class:....................................................................................................................F2

WARNING: Not suitable for pumping flammable or combustible liquids or use in a hazardous duty environment.

DATA-ENC-05-17

PSI (BAR) FT (M)

GPM(LPM)

5 4

6

PSI (BAR) FT (M)

GPM(LPM)

13

2

Technical Specifications

Enclosure: ...........................................................................................................TEFC (IP54)Available Voltage: .....................................................................SP-ENC & SP-ENC-V : 110V

Horsepower (Watts):...............................................................................................1.1 (825)

Phase:.................................................................................................................................1Amps:.............................................................................................2.5 - 8 (varies by voltage)Frequency: .............................................................................................................50-60 Hz

Certification:.....................................................................................ETL (110V) or CE (220V)Housing Material:...................................................................................Anodized AluminumPower Cord Length:..........................................................................................16 ft. (4,8 m)

Power Cord Plug Type:..............................................NEMA 5-15-P (110V) or CEE 7/7 (220V)

Noise Level:...............................................................................................................88 dBa

Low Voltage Release:............................................................SP-ENC-2 & SP-ENC-2-V : Yes

Thermal Overload:..........................................................................................................Yes

Variable Speed:.........................................SP-ENC-V, SP-ENC-2-V, & SP-ENC-2-VNL : Yes

Drum Pump Motors | SP-ENC Series

Weight:............................................................................................................13 lbs (5,9 kg)

.......................................................SP-ENC, SP-ENC-V, SP-ENC-2NL & SP-ENC-2-VNL : No

...............................................................................SP-ENC, SP-ENC-2 & SP-ENC-2NL : No

............................................SP-ENC-2, SP-ENC-2-V, SP-ENC-2NL & SP-ENC-2-VNL : 220V

Page 3: Drum Pump Motors SP-280P Series - AIQSA

Certification:.........SP-410EX : CSA Class I, Div. I, Group D, Insulation Class B, Temp Code T3C

DATA-400-05-17

PSI (BAR) FT (M)

GPM(LPM)

5 4

6

PSI (BAR) FT (M)

GPM(LPM)

13

2

Technical Specifications

Enclosure: ............................................................................................Explosion Proof (IP54)

Available Voltage: .....................................................................................SP-410EX : 110V

Horsepower (Watts):............................................................................SP-410EX : 0.3 (230)

Phase:.................................................................................................................................1Amps:.............................................................................................2 - 2.6 (varies by voltage)

Frequency: .............................................................................................................50-60 Hz

...........................................................................................SP-420EX : Atex II 2G Ex d IIA T4

Housing Material:..........................................Aluminum (Inner Housing) / Nylon (Outer Shell)

Power Cord Length:..........................................................................................12 ft. (3,7 m)

Power Cord Plug:..............................................................................................Not Provided

Noise Level:...............................................................................................................80 dBa

Thermal Overload:............................................................................................................No

Variable Speed:................................................................................................................No

Drum Pump Motors | SP-400 Series

Weight:............................................................................................................17 lbs (7,7 kg)

II 2G Ex d IIA T4

WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.

NOTE: Explosion proof motor regulations require that motors be returned to the manufacturer for repair.

.............................................................................................................SP-420EX : 0.8 (600)

...................................................................................................................SP-420EX : 220V

Page 4: Drum Pump Motors SP-280P Series - AIQSA

DATA-A1-05-17

PSI (BAR) FT (M)

GPM(LPM)

5 4

6

PSI (BAR) FT (M)

GPM(LPM)

13

2

Technical Specifications

Power Type: ...........................................................................................................Pneumatic

Horsepower (Watts):...............................................................................................0.5 (370)

Certification:.............................................................................................Atex II 2 G c IIB T4Housing Material:..................................................................................................Cast Steel

Noise Level:................................................................................................................78 dBa

Drum Pump Motors | SP-A1

Weight:............................................................................................................2.7 lbs (1,2 kg)

II 2 G c IIB T4

WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.

Note: Not recommended for use with the SP-700SR or 800SR Series pump.

Air Consumption:.........................................................27 CFM (13 l/sec) @ 80 psi (5.51 bar)

Air Inlet / Exhaust Size:......................................................................1/8" npt(f) / 1/8" npt(f)

Lubrication Required:.............................................................................................Yes, Daily

Adapter Material:.........................................................................................................Nylon

Page 5: Drum Pump Motors SP-280P Series - AIQSA

DATA-A2-05-17

PSI (BAR) FT (M)

GPM(LPM)

5 4

6

PSI (BAR) FT (M)

GPM(LPM)

13

2

Technical Specifications

Power Type: ...........................................................................................................Pneumatic

Horsepower (Watts):.............................................................................................0.75 (560)

Trigger Lock:........................................................................................................SP-A2 : No

Housing / Adapter Material:..................................................................................Aluminum

Noise Level:................................................................................................................87 dBa

Drum Pump Motors | SP-A2 Series

Weight:............................................................................................................3.4 lbs (1.5 kg)

WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.

Note: Not recommended for use with the SP-700SR or 800SR Series pump.

Air Consumption:......................................................28 CFM (13.2 l/sec) @ 100 psi (6,8 bar)

Air Inlet / Exhaust Size:......................................................................1/4" npt(f) / 3/8" npt(f)

Lubrication Required:.............................................................................................Yes, Daily

........................................................................................................................SP-A2TL : Yes