Download - UNIT HEATERS

Transcript
Page 1: UNIT HEATERS

UNIT HEATERS

Page 2: UNIT HEATERS

GHND/GHPD» Propeller Type Fan» Size 100 – 400 MBH» 80% Thermal Efficiency» Natural or LP Gas» 10 Year Warranty on Heat Exchanger,

Burners, and Flue Collector» ODP Motors Standard, TE Optional» Adjustable Power Venter Assembly

˃ Allows Greater Venting Flexibility. Can be rotated up to 90 Degrees in Each Direction.

» Heavy Duty Fan Guard ˃ OSHA Type Optional

» Easy Access to High Limit Control and Pilot Access» All Controls are Accessible without Removing

Side Jacket Panels

Page 3: UNIT HEATERS

GBND/GBPD» Same Components as the

GHND/GHPD Except the Propeller Assembly is Replaced with a Centrifugal Blower Assembly

» Size 100 - 400 MBH» 80% Thermal Efficiency» Belt Guard is Standard» Double Blowers with Single Shaft

Utilized on Units Size 300 - 400 MBH» 4 Point Suspension» Blower Allows Unit to Handle

Greater Static» Lower Operating Noise

Page 4: UNIT HEATERS

Separated Combustion Units

Page 5: UNIT HEATERS

GAND/GAPD» Propeller Style Unit Heater Designed for

Dusty, Dirty, Mildly Corrosive Environments and Areas of High Humidity and Slight Negative Pressures

» Separates the Unit’s Combustion Process from the Environment in Which the Unit is Installed by Taking Combustion Air from Outside the Contaminated Space

» Sizes Ranging from 100 - 400 MBH» 80% Thermal Efficiency» 1 Year Warranty on Heat Exchangers,

Burners and Flue Collectors» Power Venter Assembly Draws in the

Outside Combustion Air and Discharges Flue Gas

» Hinged Bottom Door Allows for Complete Access to Burners and Controls

Page 6: UNIT HEATERS

GKND/GKPD» Same Components as the GAND/GAPD

Except the Propeller Assembly is Replaced with a Centrifugal Blower

» Available in Sizes 100 - 400 MBH» 80% Thermal Efficiency» Belt Guard is Standard» 1 Year Warranty on Heat Exchanger,

Burners and Flue Collector» Double Blowers with Single Shaft

Utilized on Units Size 300 - 400 MBH» 4 Point Suspension» Blower allows unit to handle greater

static» Lower Operating Noise

Page 7: UNIT HEATERS

Indoor Duct Furnaces

Page 8: UNIT HEATERS

GLND/GLPD, option K or M» Side Access Burner Drawer» Sizes Ranging from 100 - 400 MBH» 30 - 80 ° F Temperature Rise» 80% Thermal Efficiency» 409 Stainless Steel Heat Exchanger

Recommended when Installed Downstream of Cooling Coil

» High Limit Accessible Through Side of Unit. Located Below 4x4 Junction Box

» 1 Year Warranty on Heat Exchanger, Burners, and Draft Diverter

Page 9: UNIT HEATERS

GLND/GLPD» Bottom Access Burner Drawer» 30 - 80 ° F Temperature Rise» 80% Efficient» Same Features as Side Access Models » Air Flow Baffle Required to Direct Air

to the Bottom of Heat Exchanger Where the Highest Amount of Heat Transfer is Occurring

» 1 Year Warranty on Heat Exchanger, Burners, and Draft Diverter

» High Limit has Spring Loaded Assembly to Insure Contact with Heat Exchanger Header

Page 10: UNIT HEATERS

GMND/GMPD» Same Components as the GAND/GAPD

Except the Supply Air Fan is Removed from the Unit

» Sizes Ranging from 100 to 400 MBH» 20 - 90 ° F Temperature Rise» 80% Thermal Efficiency.» 1 Year Warranty on Heat Exchanger,

Burners, and Flue Collectors» 4 Point Suspension» Bottom Access Only to Burner Drawer

Page 11: UNIT HEATERS

Tubular Gas Fired Unit Heaters

Trane’s most versatile product line

Page 12: UNIT HEATERS

GTND/GTPD – 30 to 120 MBH» ETL Certified for Residential Garage

Installations» Sizes Ranging from 30 to 120 MBH» Low Profile Design Ideal for Low

Clearance Installations» Over 82% Thermal Efficiency» Heavy Duty OSHA Fan Guard» Single Burner Design» LED Diagnostic Control Board» Open Drip Proof Motor Standard» 10 Year Heat Exchanger Warranty» Field Convertible to Separated

Combustion» Gas Conversion Kit Included

Page 13: UNIT HEATERS

GTND/GTPD – 150 to 400 MBH» Sizes from 150 to 400 MBH» 83% Thermal efficiency» Interior Baffles Aid in Heat Transfer and

Increase Outlet Velocity for Increased Throw Delivery

» Isolated Control Panel for Service Convenience

» Multiple In-Shot Burner Design» Direct Spark Ignition» Thermostat wires to an exterior terminal

strip located under the control cabinet access door for ease of installation

» Tubular Heat Exchanger for Long Life. » 10 Year Heat Exchanger Warranty

Page 14: UNIT HEATERS

Hydronic Unit Heaters

Page 15: UNIT HEATERS

UHSB – Header Type» (19) Sizes 18 - 360 MBH» OSHA Fan Guard Standard on 18 – 48

MBH = Residential Certified» Available for use with Steam or Hot

Water» Coil Connections on Top and Bottom of

Unit» Coil Constructed of Copper Tubes with

Aluminum Fins» Factory Tested at 200 PSI» Totally Enclosed Fan Motor Standard,

Explosion Proof Motor Optional» 1 Year Warranty

Page 16: UNIT HEATERS

UHSBA – Serpentine» (4) Sizes 8 - 36 MBH» Hot Water Only» Coil Connections on Side of Unit» OSHA Fan Guard is Standard» Residential Certified» Coil Constructed of Copper Tubes

with Aluminum Fins» Factory Tested at 200 PSI» Totally Enclosed Fan Motor

Standard, Explosion Proof Motor Optional

» 1 Year Warranty

Page 17: UNIT HEATERS

UHPB» (15) Sizes 41-705 MBH» Available in Steam or Hot Water» Coil Connections on Top and

Bottom of Unit» Copper Coil with Aluminum Fins

Mechanically Bonded to the Tubes» Coils are Tested at 375 PSI» Threaded Steel Pipe Coil

Connections» Totally Enclosed Fan Motor

Standard, Explosion Proof Motor Optional

» 1 Year Warranty

Page 18: UNIT HEATERS

Engineered Products

Page 19: UNIT HEATERS

Trane Offers a Complete Line of Outdoor and Indoor HVAC Equipment to Satisfy Make-Up Air Needs

Page 20: UNIT HEATERS

Outdoor Unit Types» Model “GR” Option “G”– Gravity Vented Outdoor» Model “GR” Option “P”– Power Vented Outdoor

Page 21: UNIT HEATERS

Indoor Unit Types» Model “GG” – Power Vented Indoor

Page 22: UNIT HEATERS

Indoor Unit Types» Model “GX” – Separated Combustion Indoor

Page 23: UNIT HEATERS

Outdoor Units Types» Model “AH” Air Handler

Page 24: UNIT HEATERS

Arrangements» Consists of Individual Pre-Engineered Modules Arranged to

Address Your Individual Applications

Page 25: UNIT HEATERS

Furnace Type» Trane GR Duct Furnaces are Available in Two

Types.˃ Standard Temperature Rise (20°- 60°F)˃ High Temperature Rise (60°- 90°F)

» GG/GX 30°- 80° Rise Only

» Furnace Type Also Determines the Unit Access Side (Left or Right) Based on the Direction of Airflow Through the Unit.

Page 26: UNIT HEATERS

Furnace Construction Material

» Stainless Steel Packages: Provides a Total Package Protection by Including 409 SS Burners and Flue Collector

Duct Furnace Heat Exchangers are Available in 3 Types of Steel

Aluminized Steel

409 Stainless Steel

321 Stainless Steel

Page 27: UNIT HEATERS

Gas Controls» A Full Range of Gas Controls, Including:

» Single Stage

» Two Stage

» Electronic Modulation˃ Room Sensing˃ Duct Sensing (W/, W/O Rm. O/R)˃ Others, Including 4-20 mA & 0-10 VDC Controls and

Multi-Furnace Staging

Page 28: UNIT HEATERS

Coil Options» Factory Installed Coils

˃ Direct Expansion (DX)˃ Chilled Water˃ Steam ˃ Hot water

» Draw Through Design Maximizes Coil Efficiencies

» Full Size ASHRAE 62 Compliant Drain Pan

» 4 Row & 6 Row, Single or Dual Circuit

» Cooling Coil 1,000-6,300 CFM Range*

» 3-30 Tons, But There is Flexibility. When in Doubt, Call!

Page 29: UNIT HEATERS

Features and Benefits

» Standard Left Hand Access, Right Hand Optional» Multiple Gas and Air Control Options» 1” Matte Face Insulation

Page 30: UNIT HEATERS

Features and Benefits

» Economizer Control Door Safety Interlock

Page 31: UNIT HEATERS

Features and Benefits Ship Loose Parts List

Page 32: UNIT HEATERS

Motor Types Totally Enclosed (TE) Premium Efficiency (PETE)

» Open Drip Proof (ODP)» Premium Efficiency (PEODP)

Page 33: UNIT HEATERS

Air Inlet Configuration» Indicates ˃ Use of Outside and / or Return Air ˃ Use of an Air Hood (Shipped Separately)

Page 34: UNIT HEATERS

Air Control & Damper Arrangements

» Twenty Air Control Options Available» Options Range From Simple Two-Position

Dampers (Open & Closed) to Various Modulating Controls to ASHRAE Cycles I, II & III

» Other Options Available Including Enthalpy Controlled Economizer, Pressure Sensing & CO2 Monitoring

» Refer the Catalog For Full Descriptions of the Air Control and Damper Arrangements

Page 35: UNIT HEATERS

Factory Installed Options» Low Leak Damper» 409 SS Furnace Drip Pan» High Altitude Derate» Input Derate» Evaporative Cooler

˃ 12” CELdek® Media˃ 8” & 12“ GLASdek ® Media

» Clogged Filter Switch» Manual Blower Switch» Firestat (Supply and / or Return)» Freezestat (Time Delayed)» Ambient Lockout

» Interlock Relays (Specify Purpose)

» Moisture Eliminators» Horizontal Return» Status Lamps» Double Wall Construction» Service Convenience Package» High / Low Gas Pressure Switch» Filters (TA, WA & Pleated)» Through the Base Utility

Penetrations

Page 36: UNIT HEATERS

Field Installed Accessories» High Pressure Regulators» Time Clocks» GFI Convenience Outlet» Thermostats» DuctStats» Disconnect Switches

» Evaporative Cooler ˃ Fill & Drain Kit˃ Freezestat

» Remote Control Panel


Top Related