ROOM AIR CONDITIONING ■
UTOPIA SPLITS ■
SET FREE VRF ■
SYSTEM FREE ■
VENTILATION ■
CONTROL SYSTEMS ■
DOMESTIC HEATING ■
AIR CONDITIONING
PRICE LIST 2017
HITACHI’S RANGE OF INNOVATIVE HEATING AND COOLING PRODUCTS FOR HOME, COMMERCIAL AND INDUSTRIAL
APPLICATIONS ARE ENGINEERED FOR SEASONAL EFFICIENCY AND COME WITH
A GENEROUS 5-YEAR* WARRANTY.
*3-YEAR WARRANTY ON RAC AND CONTROLS
ROOM AIR CONDITIONINGCOMPACT AND STYLISH RAC DESIGNS WITH HIGH SEASONAL EFFICIENCY AND LOW NOISE,
INCLUDING S-SERIES WHICH ELIMINATES 99% OF AIRBORNE ALLERGENS AND BACTERIA.
WALL MOUNTED / P.4-7FLOOR MOUNTED / P.8-9
MONOZONE DUCTED / P.10-11CASSETTE / P.12
MULTIZONE OUTDOOR / P.13MULTIZONE INDOOR / P.14-18
3
4
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 18WEC
2.0 (1.99) 2.5 5.8/3.8 A+/A 1/4" - 3/8" 20/10 0.72/- 1 Ph to Outdoor 3 + E 16
530x660x278 24.5 Summit Heat Pump R410a Outdoor Unit
£480RAK 18PEC 280x780x218 7.5
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 25WEC
2.5 (2.28) 3.4 5.8/3.8 A+/A 1/4" - 3/8" 20/10 0.72/- 1 Ph to Outdoor 3 + E 16
530x660x278 24.5 Summit Heat Pump R410a Outdoor Unit
£504RAK 25PEC 280x780x218 7.5
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 35WEC
3.5 (2.87) 4.2 5.85/3.8 A+/A 1/4" - 3/8" 20/10 0.95/- 1 Ph to Outdoor 3 + E 16
530x660x278 27.5 Summit Heat Pump R410a Outdoor Unit
£595RAK 35PEC 280x780x218 7.5
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 50WEC
5.0 (3.47) 6.0 5.88/3.8 A+/A 1/4" - 1/2" 20/10 1.25/- 1 Ph to Outdoor 3 + E 25
600x792x299 40.0 Summit Heat Pump R410a Outdoor Unit
£791RAK 50PEC 280x780x218 8.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC3 Card Key Contact £12
SPX-WDC5+HAS100TSA Card Key & Malfunction Dry Contact Kit £65
SPX-WDC7+HAS100TSA Malfunction Dry Contact Kit £65
RAK-PEC
ROOM AIR CONDITIONING / WALL MOUNTED:
SUMMIT
5
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 18WPB
2.0 (1.9) 2.5 7.0/4.3 A++/A+ 1/4" - 3/8" 20/10 0.95/- 1 Ph to Outdoor 3 + E 16
530x660x278 27.5 Performance Heat Pump R410a Outdoor Unit
£560RAK 18RPB 280x780x218 7.5
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 25WPB2.5 (2.2) 3.4 7.6/4.4 A++/A+ 1/4" - 3/8" 20/10 0.95/- 1 Ph to
Outdoor 3 + E 16 530x660x278 27.5 Performance Heat Pump
R410a Outdoor Unit £594RAK 25RPB 280x780x218 7.5 Wall Mounted Indoor Unit
RAC 35WPC
3.5 (2.7) 4.2 7.2/4.6 A++/A+ 1/4" - 3/8" 20/10 1.05/- 1 Ph to Outdoor 3 + E 16
548x750x288 33.0 Performance Heat Pump R410a Outdoor Unit (
£697RAK 35RPC 295x900x230 10.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 50WPC
5.0 (3.8) 6.0 7.2/4.41 A++/A+ 1/4" - 1/2" 20/10 1.25/- 1 Ph to Outdoor 3 + E 25
600x792x299 41.0 Performance Heat Pump R410a Outdoor Unit
£929RAK 50RPC 295x900x232 10.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 60WPA
6.1 (4.4) 6.8 6.0/4.0 A+/A+ 1/4" - 1/2" 30/20 1.65/- 1 Ph to Outdoor
3 + 2 Core Screened 25
650x850x298 45.0 Performance Heat Pump R410a Outdoor Unit
£1,314RAK 60PPA 295x1030x207 12.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 70WPA
7.0 (5.4) 8.0 6.8/4.41 A++/A+ 1/4" - 5/8" 30/20 1.85/- 1 Ph to Outdoor
3 + 2 Core Screened 32
800x850x298 55.0 Performance Heat Pump R410a Outdoor Unit
£1,747RAK 70PPA 333x1150x245 15.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC3 Card Key Contact (RAK-RPB & RPC Only) £12
SPX-WDC4 Card Key Contact (RAK-PPA) £12
SPX-WDC5+HAS100TSA Card Key & Malfunction Dry Contact Kit (RAK-RPB & RPC Only) £65
ROOM AIR CONDITIONING / WALL MOUNTED:
PERFORMANCE RAK-WPB/CRAK-PPA
6
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 25WXB
2.5 (2.3) 3.2 8.5/4.7 A+++/A++ 1/4" - 3/8" 20/10 1.08/- 1 Ph to Outdoor 3 + E 16
548×750×288 34.0 Shirokuma Heat Pump R410a Outdoor Unit
£739RAK 25RXB 295x900x210 11.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 35WXB
3.5 (3.0) 4.0 8.5/4.72 A+++/A++ 1/4" - 3/8" 20/10 1.17/- 1 Ph to Outdoor 3 + E 16
548×750×288 34.0 Shirokuma Heat Pump R410a Outdoor Unit
£850RAK 35RXB 295x900x210 11.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 50WXB
5.0 (3.7) 5.8 7.2/4.5 A++/A+ 1/4 - 1/2" 30/10 1.35/- 1 Ph to Outdoor 3 + E 25
736×800×350 49.5 Shirokuma Heat Pump R410a Outdoor Unit
£1,241RAK 50RXB 295x900x210 11.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC3 Card Key Contact £12
SPX-WDC5+HAS100TSA Card Key & Malfunction Dry Contact Kit £65
SPX-WDC7+HAS100TSA Malfunction Dry Contact Kit £65
ROOM AIR CONDITIONING / WALL MOUNTED:
SHIROKUMA RAK-RXB
7
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 18WSB
1.8 (1.8) 2.3 7.41/4.6 A++/A++ 1/4 - 1/2" 20/10 1.35/- 1 Ph to Outdoor 3 + E 25
600x792x299 40.0 S Series Heat Pump R410a Outdoor Unit
£1,187RAK 18PSB 295x798x258 12.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 25WSB
2.5 (2.2) 3.2 8.50/4.68 A+++/A++ 1/4 - 1/2" 20/10 1.35/- 1 Ph to Outdoor 3 + E 25
600x792x299 40.0 S Series Heat Pump R410a Outdoor Unit
£1,230RAK 25PSB 295x798x258 12.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 35WSB
3.5 (2.7) 4.0 8.50/4.72 A+++/A++ 1/4 - 1/2" 20/10 1.35/- 1 Ph to Outdoor 3 + E 25
600x792x299 40.0 S Series Heat Pump R410a Outdoor Unit
£1,363RAK 35PSB 295x798x258 12.0
Wall Mounted Indoor Unit, c/w Wireless Remote
Controller
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC3 Card Key Contact £12
ROOM AIR CONDITIONING / WALL MOUNTED:
S-SERIES RAK-PSB
8
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 25FPA
2.5 (2.3) 3.4 5.8/4.3 A+/A+ 1/4" - 3/8" 20/10 0.87/- 1 Ph to Outdoor 2 Core Screened 16
548x750x288 31.0 Summit Heat Pump R410a Outdoor Unit
£1061RAF 25RPA 600x760x235 14.0
Floor Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 35FPA
3.5 (2.9) 4.2 6.0/4.3 A+/A+ 1/4" - 3/8" 20/10 1.05/- 1 Ph to Outdoor 2 Core Screened 16
548x750x288 35.0 Summit Heat Pump R410a Outdoor Unit
£1213RAF 35RPA 600x760x235 14.0
Floor Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 50FPA
5.0 (3.8) 6.0 5.9/4.0 A+/A+ 1/4" - 1/2" 20/10 1.25/- 1 Ph to Outdoor 2 Core Screened 25
600x792x299 40.0 Summit Heat Pump R410a Outdoor Unit
£1453RAF 50RPA 600x760x235 14.0
Floor Mounted Indoor Unit, c/w Wireless Remote
Controller
Accessories
Model No. Description List Price
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC1 Card Key Contact £12
ROOM AIR CONDITIONING / FLOOR MOUNTED:
STANDARD RAF-FPA
9
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 25FXB
2.5 (2.5) 3.4 6.38/4.24 A++/A+ 1/4" - 3/8" 20/10 0.87/- 1 Ph to Outdoor 3 + E 16
548x750x288 32 Shirokuma Heat Pump R410a Outdoor Unit
£1,462RAF 25RXB 590x750x215 15
Floor Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 35FXB
3.5 (2.9) 4.5 6.39/4.14 A++/A+ 1/4" - 3/8" 20/10 0.87/- 1 Ph to Outdoor 3 + E 16
548x750x288 32 Shirokuma Heat Pump R410a Outdoor Unit
£1,485RAF 35RXB 590x750x215 15
Floor Mounted Indoor Unit, c/w Wireless Remote
Controller
RAC 50FXB
5.0 (3.8) 6.0 5.97/4.15 A+/A+ 1/4" - 1/2" 30/10 1.4/- 1 Ph to Outdoor 3 + E 25
736x800x350 50 Shirokuma Heat Pump R410a Outdoor Unit
£1,893RAF 50RXB 590x750x215 15
Floor Mounted Indoor Unit, c/w Wireless Remote
Controller
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC3 Card Key Contact £12
SPX-WDC5+HAS100TSA Card Key & Malfunction Dry Contact Kit £65
SPX-WDC7+HAS100TSA Malfunction Dry Contact Kit £65
ROOM AIR CONDITIONING / FLOOR MOUNTED:
SHIROKUMA RAF-RXB
10
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 25NPA2.5 (2.0) 3.5 5.1/3.8 A/A 1/4" - 3/8" 20/10 1.15/- 1Ph to
Outdoor 2 Core Screened 16570x750x280 38 Monozone R410a Heat
Pump Outdoor Unit£1,032
RAD 25RPA 235x750x400 16 Ducted Indoor Unit (No Remote Included)
RAC 35NPA3.5 (2.5) 4.8 5.1/3.8 A/A 1/4" - 3/8" 20/10 1.15/- 1Ph to
Outdoor 2 Core Screened 16570x750x280 38 Monozone R410a Heat
Pump Outdoor Unit£1,203
RAD 35RPA 235x750x400 16 Ducted Indoor Unit (No Remote Included)
RAC 50NPA5.0 (3.8) 6.0 4.7/3.8 B/A 1/4" - 1/2" 20/10 1.4/- 1Ph to
Outdoor 2 Core Screened 16650x850x298 45 Monozone R410a Heat
Pump Outdoor Unit£1,523
RAD 50RPA 235x750x400 16 Ducted Indoor Unit (No Remote Included)
Accessories
Model No. Description List Price
SPX-RCKA Wireless Remote Controller £29
SPX-RCDA Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC2 Card Key Contact £12
ROOM AIR CONDITIONING / DUCTED:
MONOZONE RAD-RPA
11
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 50DPA5.0 (4.0) 6.0 5.4/3.8 A/A 1/4" - 3/8" 30/20 1.8/- 1Ph to
Outdoor3 + 2 Core Screened 32
800x850x298 51.5 Monozone R410a Heat Pump Outdoor Unit
£1,544RAD 50PPA 270x900x720 35.0 Ducted Indoor Unit
(No Remote Included)
RAC 60DPA6.0 (4.5) 7.3 5.1/3.8 A/A 1/4" - 3/8" 30/20 1.8/- 1Ph to
Outdoor3 + 2 Core Screened 32
800x850x298 55.0 Monozone R410a Heat Pump Outdoor Unit
£1,734RAD 60PPA 270x900x720 35.0 Ducted Indoor Unit
(No Remote Included)
RAC 70DPA7.1 (5.1) 8.0 5.1/3.8 A/A 1/4" - 5/8" 30/20 1.8/- 1Ph to
Outdoor3 + 2 Core Screened 32
800x850x298 55.0 Monozone R410a Heat Pump Outdoor Unit
£1,955RAD 70PPA 270x900x720 35.0 Ducted Indoor Unit
(No Remote Included)
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCKA Wireless Remote Controller £29
SPX-RCDA Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC2 Card Key Contact £12
SPX-RTH1 Remote Sensor £29
ROOM AIR CONDITIONING / DUCTED:
MONOZONE HIGH PRESSURE RAD-PPA
12
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAC 25NPA
2.5 (2.0) 3.5 5.7/3.8 A+/A 1/4" - 3/8" 20/10 1.15/- 1Ph to Outdoor
3 + 2 Core Screened 16
570x750x280 38.0 Monozone R410a Heat Pump Outdoor Unit
£1,327RAI 25RPA 285x580x580 20.0
Cassette Indoor Unit, c/w Wireless Remote
Controller (Price Includes RAI-ECPP Grille)
RAC 35NPA
3.5 (2.9) 4.8 5.8/3.8 A+/A 1/4" - 3/8" 20/10 1.15/- 1Ph to Outdoor
3 + 2 Core Screened 16
570x750x280 38.0 Monozone R410a Heat Pump Outdoor Unit
£1,457RAI 35RPA 285x580x580 20.0
Cassette Indoor Unit, c/w Wireless Remote
Controller (Price Includes RAI-ECPP Grille)
RAC 50NPA
5.0 (3.8) 6.2 5.2/3.8 A/A 1/4" - 1/2" 20/10 1.4/- 1Ph to Outdoor
3 + 2 Core Screened 16
650x850x298 45.0 Monozone R410a Heat Pump Outdoor Unit
£1,717RAI 50RPA 285x580x580 20.0
Cassette Indoor Unit, c/w Wireless Remote
Controller (Price Includes RAI-ECPP Grille)
RAI-ECPP 32x650x650 4.0 Cassette - (RAI-25~50RPA Grille) £183
Accessories
Model No. Description List Price
SPX-RCKA Wireless Remote Controller £29
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC2 Card Key Contact £12
ROOM AIR CONDITIONING / CASSETTE:
600 X 600 CASSETTE RAI-RPA
13
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAM 33NP2B 3.3 4.0 6.30/4.30 A++/A+ 1/4"x2 - 3/8"x2 20/20 1.03/- 230/1/50 3 + E 16 570x750x280 38Multizone Heat Pump
Outdoor Unit (Maximum 2 Indoor Units)
£809
RAM 40NP2B 4 5.2 7.00/4.33 A++/A+ 1/4"x2 - 3/8"x2 35/20 1.45/- 230/1/50 3 + E 16 570x750x280 41Multizone Heat Pump
Outdoor Unit (Maximum 2 Indoor Units)
£890
RAM 53NP2B 5.3 6.8 7.15/4.31 A++/A+ 1/4"x2 - 3/8"x2 35/20 1.9/- 230/1/50 3 + E 20 750x850x298 53Multizone Heat Pump
Outdoor Unit (Maximum 2 Indoor Units)
£1,003
RAM 53NP3B 5.3 6.8 7.15/4.31 A++/A+ 1/4"x3 - 3/8"x3 45/20 1.9/20 230/1/50 3 + E 20 750x850x298 53Multizone Heat Pump
Outdoor Unit (Maximum 3 Indoor Units)
£1,083
RAM 68NP3B 6.8 8.5 6.60/4.20 A++/A+ 1/4"x3 - 3/8"x3 60/20 2.3/20 230/1/50 3 + E 20 800x850x298 58Multizone Heat Pump
Outdoor Unit (Maximum 3 Indoor Units)
£1,493
RAM 70NP4B 7 8.5 6.30/4.20 A++/A+ 1/4"x4 - 3/8"x3/1/2"x1 60/20 2.3/20 230/1/50 3 + E 20 800x850x298 58
Multizone Heat Pump Outdoor Unit
(Maximum 4 Indoor Units)£1,620
RAM 90NP5B 9 11.0 6.50/4.20 A++/A+ 1/4"x5 - 3/8"x3/1/2"x2 75/20 2.7/15 230/1/50 3 + E 25 800x950x370 71
Multizone Heat Pump Outdoor Unit
(Maximum 5 Indoor Units)£2,153
RAM 110NP6B 10.6 13.6 6.30/4.20 A++/A+ 1/4"x6 - 3/8"x6 45x2/20 3.3/20 230/1/50 3 + E 25 1450x855x308 113Multizone Heat Pump
Outdoor Unit (Maximum 6 Indoor Units)
£2,563
ROOM AIR CONDITIONING / MULTIZONE OUTDOOR UNITS:
MULTIZONE
RAM 53NP2/3B RAM 68/70NP3/4B
RAM 33/40NP2B
RAM 110NP6BRAM 90NP5B
14
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description Unit List
Price
RAK 15QPB 1.5 (1.5) 2.0 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 280x780x218 7.5 Wall Mounted Indoor Unit £190
RAK 18RPB 2.0 (1.9) 2.5 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 280x780x218 7.5 Wall Mounted Indoor Unit £200
RAK 25RPB 2.5 (2.2) 3.4 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 280x780x218 7.5 Wall Mounted Indoor Unit £216
RAK 35RPC 3.5 (2.7) 4.2 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 295x900x230 10.0 Wall Mounted Indoor Unit £233
RAK 50RPC 5.0 (3.8) 6.0 Refer to Outdoor
Refer to Outdoor 1/4" - 1/2" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 295x900x230 10.0 Wall Mounted Indoor Unit £332
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC3 Card Key Contact (RAK-RPB & RPC Only) £12
SPX-WDC4 Card Key Contact (RAK-PPA) £12
SPX-WDC5+HAS100TSA Card Key & Malfunction Dry Contact Kit (RAK-RPB & RPC Only) £65
ROOM AIR CONDITIONING / MULTIZONE INDOOR UNITS:
WALL MOUNTED - PERFORMANCE RACK-RPB/C
15
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description Unit List
Price
RAK 18QXB 1.8 (1.8) 2.5 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 295x900x210 11.0 Wall Mounted Indoor Unit £286
RAK 25RXB 2.5 (2.3) 3.2 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 295x900x210 11.0 Wall Mounted Indoor Unit £222
RAK 35RXB 3.5 (3.0) 4.0 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 295x900x210 11.0 Wall Mounted Indoor Unit £258
RAK 50RXB 5.0 (3.7) 5.8 Refer to Outdoor
Refer to Outdoor 1/4" - 1/2" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 295x900x210 11.0 Wall Mounted Indoor Unit £361
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC3 Card Key Contact £12
SPX-WDC5+HAS100TSA Card Key & Malfunction Dry Contact Kit £65
SPX-WDC7+HAS100TSA Malfunction Dry Contact Kit £65
ROOM AIR CONDITIONING / MULTIZONE INDOOR UNITS:
WALL MOUNTED - SHIROKUMA RAK-RXB
16
ROOM AIR CONDITIONING / MULTIZONE INDOOR UNITS:
600 X 600 CASSETTEModel No.
Nominal Cooling Capacity
(Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description Unit List
Price
RAI 25QPB 2.5 (2.0) 3.5 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 285x580x580 20 Cassette Indoor Unit (Price
Includes RAI-ECPP Grille) £699
RAI 35QPB 3.5 (2.9) 4.8 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 285x580x580 20 Cassette Indoor Unit (Price
Includes RAI-ECPP Grille) £735
RAI 50QPB 5.0 (3.8) 6.2 Refer to Outdoor
Refer to Outdoor 1/4" - 1/2" Refer to
Outdoor Refer to Outdoor 1Ph from Outdoor 3 + E - 285x580x580 20 Cassette Indoor Unit (Price
Includes RAI-ECPP Grille) £772
RAI-ECPP 32x650x650 4.0 Cassette - (RAI-25~50QPB Grille) £183
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCKA Wireless Remote Controller £29
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC2 Card Key Contact £12
SPX-WDC6+HAS100TSA Card Key & Malfunction Dry Contact Kit £65
HA-S100TSA Malfunction Dry Contact Kit £12
RAI-QPB
17
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description Unit List
Price
RAD 18QPB 1.8 (1.8) 2.5 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to Out-
door Refer to Outdoor 1Ph from Outdoor 3 + E - 235x750x400 16.0 Ducted Indoor Unit
(No Remote Included) £404
RAD 25QPB 2.5 (2.0) 3.5 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to Out-
door Refer to Outdoor 1Ph from Outdoor 3 + E - 235x750x400 16.0 Ducted Indoor Unit
(No Remote Included) £428
RAD 35QPB 3.5 (2.5) 4.8 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to Out-
door Refer to Outdoor 1Ph from Outdoor 3 + E - 235x750x400 16.0 Ducted Indoor Unit
(No Remote Included) £499
RAD 50QPB 5.0 (3.8) 6.0 Refer to Outdoor
Refer to Outdoor 1/4" - 1/2" Refer to Out-
door Refer to Outdoor 1Ph from Outdoor 3 + E - 235x750x400 16.0 Ducted Indoor Unit
(No Remote Included) £576
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCKA1 Wireless Remote Controller £29
SPX-RCDA Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC2 Card Key Contact £12
SPX-WDC6+HAS100TSA Card Key & Malfunction Dry Contact Kit £65
HA-S100TSA Malfunction Dry Contact Kit £12
SPX-RTH1 Remote Sensor £29
ROOM AIR CONDITIONING / MULTIZONE INDOOR UNITS:
DUCTED RAD-QPB
18
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description Unit List
Price
RAF 25RXB 2.5 (2.5) 3.4 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to Out-
door Refer to Outdoor 1Ph from Outdoor 3 + E - 590x750x215 15
Floor - Mono-Multizone (inc. RAR-6N4 Wireless Remote, Nano-Stainless Pre-Filter and Wasabi Air
Purifying Filter)
£924
RAF 35RXB 3.5 (2.9) 4.5 Refer to Outdoor
Refer to Outdoor 1/4" - 3/8" Refer to Out-
door Refer to Outdoor 1Ph from Outdoor 3 + E - 590x750x215 15
Floor - Mono-Multizone (inc. RAR-6N4 Wireless Remote, Nano-Stainless Pre-Filter and Wasabi Air
Purifying Filter)
£926
RAF 50RXB 5.0 (3.8) 6 Refer to Outdoor
Refer to Outdoor 1/4" - 1/2" Refer to Out-
door Refer to Outdoor 1Ph from Outdoor 3 + E - 590x750x215 15
Floor - Mono-Multizone (inc. RAR-6N4 Wireless Remote, Nano-Stainless Pre-Filter and Wasabi Air
Purifying Filter)
£931
Accessories
Model No. Description List Price
SPX-WKT2 LCD Advancved Wired Remote Controller with 7 Day Timer £101
SPX-WKT5M 5m Extension Cable for SPX-WKT2 £18
SPX-RCDB Simple Wired Remote Controller £29
SPX-DST1 Distributor Kit to enable group control of up to 13 indoor units £23
SPX-WDST8M Wiring Kit - SPX-DST1 (8 metre cable length) £16
PSC-6RAD H-Link Adaptor £97
SPX-WDC3 Card Key Contact £12
SPX-WDC5+HAS100TSA Card Key & Malfunction Dry Contact Kit £65
SPX-WDC7+HAS100TSA Malfunction Dry Contact Kit £65
ROOM AIR CONDITIONING / MULTIZONE INDOOR UNITS:
FLOOR MOUNTED - SHIROKUMA RAF-RXB
UTOPIA SPLITSOPTIMISED TO MAXIMISE SEASONAL EFFICIENCIES, EVEN AT PARTIAL LOAD, UTOPIA IVX PREMIUM
AND COMFORT MODELS ARE ALSO ERP DIRECTIVE TIER 2 COMPLIANT.
ES SERIES / P.20-21IVX COMFORT / P.22-23IVX PREMIUM / P.24-26 IVX CENTRIFUGAL / P.26
19
20
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAS 3HVRNS3 7.1 8.0 3.05/3.88 A/A 3/8" - 5/8" 50/30 1.9(20)/30 230/1/50 2 Core Screened 20 600x792x300 44Utopia ES Heat Pump
R410a Inverter 1Ø Outdoor Unit
£1,050
RAS 4HVRNS3E 10.0 11.2 3.69/4.16 B/A 3/8" - 5/8" 50/30 2.9(30)/40 230/1/50 2 Core Screened 32 800x950x370 67Utopia ES Heat Pump
R410a Inverter 1Ø Outdoor Unit
£1,237
RAS 5HVRNS3E 12.5 14.0 3.23/3.7 A/A 3/8" - 5/8" 50/30 3.2(30)/60 230/1/50 2 Core Screened 32 1140x950x370 89Utopia ES Heat Pump
R410a Inverter 1Ø Outdoor Unit
£1,440
RAS 6HVRNS3E 14.0 16.0 2.9/3.29 C/C 3/8" - 5/8" 50/30 3.2(30)/60 230/1/50 2 Core Screened 32 1140x950x370 89Utopia ES Heat Pump
R410a Inverter 1Ø Outdoor Unit
£1,666
RAS 4HRNS3E 10.0 11.2 3.69/4.16 B/A 3/8" - 5/8" 50/30 2.9(30)/40 400/3/50 2 Core Screened 20 800x950x370 67Utopia ES Heat Pump
R410a Inverter 3Ø Outdoor Unit
£1,334
RAS 5HRNS3E 12.5 14.0 3.23/3.7 A/A 3/8" - 5/8" 50/30 3.2(30)/60 400/3/50 2 Core Screened 20 1140x950x370 89Utopia ES Heat Pump
R410a Inverter 3Ø Outdoor Unit
£1,626
RAS 6HRNS3E 14.0 16.0 2.9/3.29 C/C 3/8" - 5/8" 50/30 3.2(30)/60 400/3/50 2 Core Screened 20 1140x950x370 89Utopia ES Heat Pump
R410a Inverter 3Ø Outdoor Unit
£1,862
RAS 8HRNSE 20.0 22.4 3.01/3.42 B/B 3/8" - 1 1/8" 50/30 6.0(30)/65 400/3/50 2 Core Screened 32 1380x950x370 135Utopia ES Heat Pump
R410a Inverter 3Ø Outdoor Unit
£2,960
RAS 10HRNSE 25.0 28.0 2.81/3.21 C/C 1/2" - 1 1/8" 50/30 6.2(30)/120 400/3/50 2 Core Screened 32 1380x950x370 141Utopia ES Heat Pump
R410a Inverter 3Ø Outdoor Unit
£3,334
UTOPIA / CONDENSING UNITS:
ES SERIES RAS-H(V)RNS3ERAS HVRNS3
21
UTOPIA / SYSTEM PRICES:
ES SINGLE SPLIT SYSTEMSIndoor Unit Type Power Cooling Capacity (kW) Heating Capacity (kW) Outdoor Unit Indoor Unit Controller List Price
4 Way Cassette (RCI.FSN4)
Single Phase
7.1 5.6 RAS-3HVRNS3E RCI-3.0FSN4+P-N23NA2 PC-ARFPE £2,105
10.0 11.2 RAS-4HVRNS3E RCI-4.0FSN4+P-N23NA2 PC-ARFPE £2,374
12.5 14.0 RAS-5HVRNS3E RCI-5.0FSN4+P-N23NA2 PC-ARFPE £2,683
14.0 16.0 RAS-6HVRNS3E RCI-6.0FSN4+P-N23NA2 PC-ARFPE £3,085
Three Phase
10.0 11.2 RAS-4HRNS3E RCI-4.0FSN4+P-N23NA2 PC-ARFPE £2,471
12.5 14.0 RAS-5HRNS3E RCI-5.0FSN4+P-N23NA2 PC-ARFPE £2,869
14.0 16.0 RAS-6HRNS3E RCI-6.0FSN4+P-N23NA2 PC-ARFPE £3,281
Ceiling Suspended (RPC.FSN3E)
Single Phase
7.1 5.6 RAS-3HVRNS3E RPC-3.0FSN3E PC-ARFPE £1,972
12.5 14.0 RAS-5HVRNS3E RPC-5.0FSN3E PC-ARFPE £2,616
14.0 16.0 RAS-6HVRNS3E RPC-6.0FSN3E PC-ARFPE £3,050
Three Phase12.5 14.0 RAS-5HRNS3E RPC-5.0FSN3E PC-ARFPE £2,802
14.0 16.0 RAS-6HRNS3E RPC-6.0FSN3E PC-ARFPE £3,246
High Efficiency Ceiling Suspended (RPC.FSN3)
Single Phase12.5 14.0 RAS-5HVRNS3E RPC-5.0FSN3 PC-ARFPE £2,918
14.0 16.0 RAS-6HVRNS3E RPC-6.0FSN3 PC-ARFPE £3,411
Three Phase12.5 14.0 RAS-5HRNS3E RPC-5.0FSN3 PC-ARFPE £3,104
14.0 16.0 RAS-6HRNS3E RPC-6.0FSN3 PC-ARFPE £3,607
Ducted (RPI.FSN3/4E)
Single Phase
7.1 5.6 RAS-3HVRNS3E RPI-3.0FSN4E PC-ARFPE £1,896
10.0 11.2 RAS-4HVRNS3E RPI-4.0FSN4E PC-ARFPE £2,182
12.5 14.0 RAS-5HVRNS3E RPI-5.0FSN4E PC-ARFPE £2,483
14.0 16.0 RAS-6HVRNS3E RPI-6.0FSN4E PC-ARFPE £2,882
Three Phase
10.0 11.2 RAS-4HRNS3E RPI-4.0FSN4E PC-ARFPE £2,279
12.5 14.0 RAS-5HRNS3E RPI-5.0FSN4E PC-ARFPE £2,669
14.0 16.0 RAS-6HRNS3E RPI-6.0FSN4E PC-ARFPE £3,078
20.0 22.4 RAS-8HRNSE RPI-8.0FSN3E PC-ARFPE £4,699
25.0 28.0 RAS-10HRNSE RPI-10FSN3E PC-ARFPE £5,199
Wall Mounted (RPK.FSN3M) Single Phase 7.1 5.6 RAS-3HVRNS3E RPK-3.0FSN3M PC-ARFPE £1,947
22
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAS 3HVNC1 7.1 8.0 3.14/4.0 A+/A+ 3/8" - 5/8" 50/30 1.9(20)/40 230/1/50 2 Core Screened 20 600x792x300 44 Utopia IVX Comfort Heat Pump 1Ø Outdoor Unit £1,273
RAS 4HVNC1E 10.0 11.2 3.7/4.57 A++/A+ 3/8" - 5/8" 70/30 3.2(30)/40 230/1/50 2 Core Screened 32 1140x950x370 79 Utopia IVX Comfort Heat Pump 1Ø Outdoor Unit £1,432
RAS 5HVNC1E 12.5 14.0 3.37/3.89 A/A 3/8" - 5/8" 75/30 3.2(30)/60 230/1/50 2 Core Screened 32 1140x950x370 89 Utopia IVX Comfort Heat Pump 1Ø Outdoor Unit £1,844
RAS 6HVNC1E 14.0 16.0 3.26/3.56 A/B 3/8" - 5/8" 75/30 3.2(30)/60 230/1/50 2 Core Screened 32 1140x950x370 89 Utopia IVX Comfort Heat Pump 1Ø Outdoor Unit £2,157
RAS 4HNC1E 10.0 11.2 3.7/4.57 A++/A+ 3/8" - 5/8" 70/30 3.2(30)/40 400/3/50 2 Core Screened 16 1140x950x370 79 Utopia IVX Comfort Heat Pump 3Ø Outdoor Unit £1,532
RAS 5HNC1E 12.5 14.0 3.37/3.89 A/A 3/8" - 5/8" 70/30 3.2(30)/60 400/3/50 2 Core Screened 16 1140x950x370 89 Utopia IVX Comfort Heat Pump 3Ø Outdoor Unit £1,966
RAS 6HNC1E 14.0 16.0 3.26/3.56 A/B 3/8" - 5/8" 70/30 3.2(30)/60 400/3/50 2 Core Screened 16 1140x950x370 89 Utopia IVX Comfort Heat Pump 3Ø Outdoor Unit £2,297
RAS 8HNCE 20.0 22.4 3.36/3.81 A/A 3/8" - 1 1/8" 100/30 5.7(30)/Calc. 400/3/50 2 Core Screened 32 1380x950x370 136 Utopia IVX Comfort Heat Pump 3Ø Outdoor Unit £3,597
RAS 10HNCE 25.0 28.0 3.02/3.63 B/A 1/2" - 1 1/8" 100/30 6.2/30/Calc. 400/3/50 2 Core Screened 32 1380x950x370 138 Utopia IVX Comfort Heat Pump 3Ø Outdoor Unit £4,053
RAS 12HNC 30.0 33.5 2.57/3.54 E/B 1/2" - 1 1/8" 100/30 6.2(30)/Calc. 400/3/50 2 Core Screened 32 1650x1100x390 168 Utopia IVX Comfort Heat Pump 3Ø Outdoor Unit £5,100
UTOPIA / CONDENSING UNITS:
IVX COMFORT
UTOPIA / SYSTEM PRICES:
IVX COMFORT SINGLE SPLIT SYSTEMSIndoor Unit Type Power Cooling Capacity (kW) Heating Capacity (kW) Outdoor Unit Indoor Unit Controller List Price
4 Way Cassette (RCI.FSN4)
Single Phase
7.1 5.6 RAS-3HVNC1 RCI-3.0FSN4+P-N23NA2 PC-ARFPE £2,328
10.0 11.2 RAS-4HVNC1E RCI-4.0FSN4+P-N23NA2 PC-ARFPE £2,569
12.5 14.0 RAS-5HVNC1E RCI-5.0FSN4+P-N23NA2 PC-ARFPE £3,087
14.0 16.0 RAS-6HVNC1E RCI-6.0FSN4+P-N23NA2 PC-ARFPE £3,576
Three Phase
10.0 11.2 RAS-4HNC1E RCI-4.0FSN4+P-N23NA2 PC-ARFPE £2,669
12.5 14.0 RAS-5HNC1E RCI-5.0FSN4+P-N23NA2 PC-ARFPE £3,209
14.0 16.0 RAS-6HNC1E RCI-6.0FSN4+P-N23NA2 PC-ARFPE £3,716
RAS-HNCERAS-H(V)NC1ERAS-HVNC1
CONTINUED...
23
UTOPIA / SYSTEM PRICES:
IVX COMFORT SINGLE SPLIT SYSTEMS
Ceiling Suspended (RPC.FSN3E)
Single Phase
7.1 5.6 RAS-3HVNC1 RPC-3.0FSN3E PC-ARFPE £2,195
10.0 11.2 RAS-4HVNC1E RPC-4.0FSN3E PC-ARFPE £2,445
12.5 14.0 RAS-5HVNC1E RPC-5.0FSN3E PC-ARFPE £3,020
14.0 16.0 RAS-6HVNC1E RPC-6.0FSN3E PC-ARFPE £3,541
Three Phase
10.0 14.0 RAS-4HNC1E RPC-4.0FSN3E PC-ARFPE £2,545
12.5 14.0 RAS-5HNC1E RPC-5.0FSN3E PC-ARFPE £3,142
14.0 16.0 RAS-6HNC1E RPC-6.0FSN3E PC-ARFPE £3,681
High Efficiency Ceiling Suspended (RPC.FSN3E)
Single Phase
7.1 5.6 RAS-3HVNC1 RPC-3.0FSN3 PC-ARFPE £2,472
10.0 11.2 RAS-4HVNC1E RPC-4.0FSN3 PC-ARFPE £2,752
12.5 14.0 RAS-5HVNC1E RPC-5.0FSN3 PC-ARFPE £3,322
14.0 16.0 RAS-6HVNC1E RPC-6.0FSN3 PC-ARFPE £3,902
Three Phase
10.0 11.2 RAS-4HNC1E RPC-4.0FSN3 PC-ARFPE £2,852
12.5 14.0 RAS-5HNC1E RPC-5.0FSN3 PC-ARFPE £3,444
14.0 16.0 RAS-6HNC1E RPC-6.0FSN3 PC-ARFPE £4,042
Ducted (RPI-FSN3/4E)
Single Phase
7.1 5.6 RAS-3HVNC1 RPI-3.0FSN4E PC-ARFPE £2,119
10.0 11.2 RAS-4HVNC1E RPI-4.0FSN4E PC-ARFPE £2,377
12.5 14.0 RAS-5HVNC1E RPI-5.0FSN4E PC-ARFPE £2,887
14.0 16.0 RAS-6HVNC1E RPI-6.0FSN4E PC-ARFPE £3,373
Three Phase
10.0 11.2 RAS-4HNC1E RPI-4.0FSN4E PC-ARFPE £2,477
12.5 14.0 RAS-5HNC1E RPI-5.0FSN4E PC-ARFPE £3,009
14.0 16.0 RAS-6HNC1E RPI-6.0FSN4E PC-ARFPE £3,513
20.0 22.4 RAS-8HNCE RPI-8.0FSN3E PC-ARFPE £5,336
25.0 28.0 RAS-10HNCE RPI-10FSN3E PC-ARFPE £5,918
Wall Mounted (RPK.FSN3M)Single Phase
7.1 5.6 RAS-3HVNC1 RPK-3.0FSN3M PC-ARFPE £2,170
10.0 11.2 RAS-4HVNC1E RPK-4.0FSN3M PC-ARFPE £2,426
Three Phase 10.0 11.2 RAS-4HNC1E RPK-4.0FSN3M PC-ARFPE £2,526
24
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAS 2HVNP1 5.0 5.6 4.03/4.68 A++/A++ 1/4" - 1/2" 50/30 1.6(30)/30 230/1/50 2 Core Screened 16 600x792x300 43 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £879
RAS 2.5HVNP1 5.6 6.3 4.18/4.92 A+/A++ 1/4" - 1/2" 50/30 1.6(30)/30 230/1/50 2 Core Screened 20 600x792x300 43 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £977
RAS 3HVNP1E 7.1 8.0 4.49/4.88 A++/A+ 3/8" - 5/8" 50/30 2.3(30)/40 230/1/50 2 Core Screened 20 800x950x370 66 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £1,898
RAS 4HVNP1E 10.0 11.2 4.68/5.16 A++/A++ 3/8" - 5/8" 75/30 4.1(30)/60 230/1/50 2 Core Screened 32 1380x950x370 103 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £2,355
RAS 5HVNP1E 12.5 14.0 3.81/4.55 A/A 3/8" - 5/8" 75/30 4.2(30)/60 230/1/50 2 Core Screened 32 1380x950x370 103 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £2,661
RAS 6HVNP1E 14.0 16.0 3.41/4.23 A/A 3/8" - 5/8" 75/30 4.2(30)/60 230/1/50 2 Core Screened 32 1380x950x370 103 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £3,068
RAS 4HNP1E 10.0 11.2 4.68/5.16 A++/A++ 3/8" - 5/8" 75/30 4.1(30)/60 400/3/50 2 Core Screened 16 1380x950x370 103 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £2,522
RAS 5HNP1E 12.5 14.0 3.81/4.55 A/A 3/8" - 5/8" 75/30 4.2(30)/60 400/3/50 2 Core Screened 16 1380x950x370 103 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £2,812
RAS 6HNP1E 14.0 16.0 3.41/4.23 A/A 3/8" - 5/8" 75/30 4.2(30)/60 400/3/50 2 Core Screened 16 1380x950x370 103 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £3,233
RAS 8HNPE 20.0 22.4 3.56/4.21 A/A 3/8" - 1 1/8" 100/30 5.7(30)/Calc. 400/3/50 2 Core Screened 32 1380x950x370 136 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £4,221
RAS 10HNPE 25.0 28.0 3.07/3.84 B/A 1/2" - 1 1/8" 100/30 6.2(30)/Calc. 400/3/50 2 Core Screened 32 1380x950x370 138 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £4,848
RAS 12HNPE 30.0 33.5 2.65/3.64 D/A 1/2" - 1 1/8" 100/30 6.7(30)/Calc. 400/3/50 2 Core Screened 32 1650x1100x390 168 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £6,483
UTOPIA / CONDENSING UNITS:
IVX PREMIUM
UTOPIA / SYSTEM PRICES:
IVX PREMIUM SINGLE SPLIT SYSTEMSIndoor Unit Type Power Cooling Capacity (kW) Heating Capacity (kW) Outdoor Unit Indoor Unit Controller List Price
4 Way Cassette (RCI.FSN4)
Single Phase
5.0 5.6 RAS-2HVNP1 RCI-2.0FSN4+P-N23NA2 PC-ARFPE £1,869
5.6 6.3 RAS-2.5HVNP1 RCI-2.5FSN4+P-N23NA2 PC-ARFPE £2,006
7.1 5.6 RAS-3HVNP1E RCI-3.0FSN4+P-N23NA2 PC-ARFPE £2,953
10.0 11.2 RAS-4HVNP1E RCI-4.0FSN4+P-N23NA2 PC-ARFPE £3,492
12.5 14.0 RAS-5HVNP1E RCI-5.0FSN4+P-N23NA2 PC-ARFPE £3,904
14.0 16.0 RAS-6HVNP1E RCI-6.0FSN4+P-N23NA2 PC-ARFPE £4,487
Three Phase
10.0 11.2 RAS-4HNP1E RCI-4.0FSN4+P-N23NA2 PC-ARFPE £3,659
12.5 14.0 RAS-5HNP1E RCI-5.0FSN4+P-N23NA2 PC-ARFPE £4,055
14.0 16.0 RAS-6HNP1E RCI-6.0FSN4+P-N23NA2 PC-ARFPE £4,652
RAS-H(V)N1PE
CONTINUED...
25
UTOPIA / SYSTEM PRICES:
IVX PREMIUM SINGLE SPLIT SYSTEMS
Ceiling Suspended (RPC.FSN3E)
Single Phase
7.1 5.6 RAS-3HVNP1E RPC-3.0FSN3E PC-ARFPE £2,820
10.0 11.2 RAS-4HVNP1E RPC-4.0FSN3E PC-ARFPE £3,368
12.5 14.0 RAS-5HVNP1E RPC-5.0FSN3E PC-ARFPE £3,837
14.0 16.0 RAS-6HVNP1E RPC-6.0FSN3E PC-ARFPE £4,452
Three Phase
10.0 14.0 RAS-4HNP1E RPC-4.0FSN3E PC-ARFPE £3,535
12.5 14.0 RAS-5HNP1E RPC-5.0FSN3E PC-ARFPE £3,988
14.0 16.0 RAS-6HNP1E RPC-6.0FSN3E PC-ARFPE £4,617
High Efficiency Ceiling Suspended (RPC.FSN3)
Single Phase
5.0 5.6 RAS-2HVNP1 RPC-2.0FSN3 PC-ARFPE £1,975
5.6 6.3 RAS-2.5HVNP1 RPC-2.5FSN3 PC-ARFPE £2,135
7.1 5.6 RAS-3HVNP1E RPC-3.0FSN3 PC-ARFPE £3,097
10.0 11.2 RAS-4HVNP1E RPC-4.0FSN3 PC-ARFPE £3,675
12.5 14.0 RAS-5HVNP1E RPC-5.0FSN3 PC-ARFPE £4,139
14.0 16.0 RAS-6HVNP1E RPC-6.0FSN3 PC-ARFPE £4,813
Three Phase
10.0 11.2 RAS-4HNP1E RPC-4.0FSN3 PC-ARFPE £3,842
12.5 14.0 RAS-5HNP1E RPC-5.0FSN3 PC-ARFPE £4,290
14.0 16.0 RAS-6HNP1E RPC-6.0FSN3 PC-ARFPE £4,978
Ducted (RPI-FSN3/4E)
Single Phase
5.0 5.6 RAS-2HVNP1 RPI-2.0FSN4E PC-ARFPE £1,653
5.6 6.3 RAS-2.5HVNP1 RPI-2.5FSN4E PC-ARFPE £1,785
7.1 5.6 RAS-3HVNP1E RPI-3.0FSN4E PC-ARFPE £2,744
10.0 11.2 RAS-4HVNP1E RPI-4.0FSN4E PC-ARFPE £3,300
12.5 14.0 RAS-5HVNP1E RPI-5.0FSN4E PC-ARFPE £3,704
14.0 16.0 RAS-6HVNP1E RPI-6.0FSN4E PC-ARFPE £4,284
Three Phase
10.0 11.2 RAS-4HNP1E RPI-4.0FSN4E PC-ARFPE £3,467
12.5 14.0 RAS-5HNP1E RPI-5.0FSN4E PC-ARFPE £3,855
14.0 16.0 RAS-6HNP1E RPI-6.0FSN4E PC-ARFPE £4,449
20.0 22.4 RAS-8HNPE RPI-8.0FSN3E PC-ARFPE £5,960
25.0 28.0 RAS-10HNPE RPI-10FSN3E PC-ARFPE £6,713
Wall Mounted (RPK.FSN3M)Single Phase
5.0 5.6 RAS-2HVNP1 RPK-2.0FSN3M PC-ARFPE £1,741
5.6 6.3 RAS-2.5HVNP1 RPK-2.5FSN3M PC-ARFPE £1,840
7.1 5.6 RAS-3HVNP1E RPK-3.0FSN3M PC-ARFPE £2,795
10.0 11.2 RAS-4HVNP1E RPK-4.0FSN3M PC-ARFPE £3,349
Three Phase 10.0 11.2 RAS-4HNP1E RPK-4.0FSN3M PC-ARFPE £3,516
26
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RASC 4HNPE 10.0 11.2 6.65 1-5 3/8" - 5/8" 75/30 4.1(30)/60 400/3/50 2 Core Screened 20 555x1415x1015 192Utopia IVX Centrifugal Fan Heat Pump R410a
Inverter 3Ø Unit£3,479
RASC 5HNPE 12.5 14.0 6.41 1-5 3/8" - 5/8" 75/30 4.2(30)/60 400/3/50 2 Core Screened 20 555x1415x1015 192Utopia IVX Centrifugal Fan Heat Pump R410a
Inverter 3Ø Unit£3,739
RASC 6HNPE 14.0 15.5 6.19 1-5 3/8" - 5/8" 75/30 4.2(30)/60 400/3/50 2 Core Screened 20 555x1415x1015 192Utopia IVX Centrifugal Fan Heat Pump R410a
Inverter 3Ø Unit£4,196
RASC 8HNPE 20.0 22.4 6.15 1-6 3/8" - 1 1/8" 100/30 5.7(30)/Calc. 400/3/50 2 Core Screened 32 620x1850x1360 300Utopia IVX Centrifugal Fan Heat Pump R410a
Inverter 3Ø Unit£5,333
RASC 10HNPE 24.0 26.0 6.13 1-6 1/2" - 1 1/8" 100/30 6.2(30)/Calc. 400/3/50 2 Core Screened 32 620x1850x1360 303Utopia IVX Centrifugal Fan Heat Pump R410a
Inverter 3Ø Unit£5,877
UTOPIA
IVX CENTRIFUGAL
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAS 3XHVNP1E 7.1 8 4.49/4.88 A++/A+ 3/8" - 5/8" 50/30 2.3(30)/40 230/1/50 2 Core Screened 20 800x950x370 66 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £1,898
RAS 4XHVNP1E 10 11.2 4.68/5.16 A++/A++ 3/8" - 5/8" 75/30 4.1(30)/60 230/1/50 2 Core Screened 32 1380x950x370 103 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £2,355
RAS 5XHVNP1E 12.5 14 3.81/4.55 A/A 3/8" - 5/8" 75/30 4.2(30)/60 230/1/50 2 Core Screened 32 1380x950x370 103 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £2,661
RAS 6XHVNP1E 14 16 3.41/4.23 A/A 3/8" - 5/8" 75/30 4.2(30)/60 230/1/50 2 Core Screened 32 1380x950x370 103 Utopia IVX Premium Heat Pump 1Ø Outdoor Unit £3,068
RAS 4XHVNP1E 10 11.2 4.68/5.16 A++/A++ 3/8" - 5/8" 75/30 4.1(30)/60 400/3/50 2 Core Screened 16 1380x950x370 103 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £2,522
RAS 5XHNP1E 12.5 14 3.81/4.55 A/A 3/8" - 5/8" 75/30 4.2(30)/60 400/3/50 2 Core Screened 16 1380x950x370 103 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £2,812
RAS 6XHNP1E 14 16 3.41/4.23 A/A 3/8" - 5/8" 75/30 4.2(30)/60 400/3/50 2 Core Screened 16 1380x950x370 103 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £3,233
RAS 8XHNPE 20 22.4 3.56/4.21 A/A 3/8" - 1 1/8" 100/30 5.7(30)/Calc. 400/3/50 2 Core Screened 32 1380x950x370 136 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £4,221
RAS 10XHNPE 25 28 3.07/3.84 B/A 1/2" - 1 1/8" 100/30 6.2(30)/Calc. 400/3/50 2 Core Screened 32 1380x950x370 138 Utopia IVX Premium Heat Pump 3Ø Outdoor Unit £4,848
UTOPIA / CONDENSING UNITS:
IVX PREMIUM DX RAS-HX(V)NP1E
RASC-HNPE
SET FREE VRFINSTALL THE SET FREE RANGE OF MODULAR, FLEXIBLE UNITS FOR HIGH RELIABILITY,
MINIMAL MAINTENANCE AND OPTIMUM ENERGY SAVINGS.
MINI / P.28SIDE FLOW / P.28
MODULAR / P.29-31CH BOXES / P.32
27
28
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAS 4FSVN3E 11.2 12.5 4.07/4.13 1-8 3/8" - 5/8" 75/30 3.6/Calc. 230/1/50 2 Core Screened 32 1380x950x370 100Mini Set Free Heat
Pump R410a Inverter 1Ø Outdoor Unit
£3,319
RAS 5FSVN3E 14.0 16.0 3.61/3.81 1-10 3/8" - 5/8" 75/30 3.6/Calc. 230/1/50 2 Core Screened 32 1380x950x370 100Mini Set Free Heat
Pump R410a Inverter 1Ø Outdoor Unit
£3,739
RAS 6FSVN3E 15.5 18.0 3.32/3.67 1-12 3/8" - 5/8" 75/30 3.6/Calc. 230/1/50 2 Core Screened 32 1380x950x370 100Mini Set Free Heat
Pump R410a Inverter 1Ø Outdoor Unit
£4,142
RAS 4FSYN3E 11.2 12.5 4.12/4.17 1-8 3/8" - 5/8" 75/30 3.6/Calc. 400/3/50 2 Core Screened 20 1380x950x370 102Mini Set Free Heat
Pump R410a Inverter 3Ø Outdoor Unit
£3,485
RAS 5FSYN3E 14.0 16.0 3.65/3.85 1-10 3/8" - 5/8" 75/30 3.6/Calc. 400/3/50 2 Core Screened 20 1380x950x370 102Mini Set Free Heat
Pump R410a Inverter 3Ø Outdoor Unit
£3,883
RAS 6FSYN3E 15.5 18.0 3.35/3.71 1-12 3/8" - 5/8" 75/30 3.6/Calc. 400/3/50 2 Core Screened 20 1380x950x370 102Mini Set Free Heat
Pump R410a Inverter 3Ø Outdoor Unit
£4,345
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional Charge
(kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description System
List Price
RAS-8FSNM 22.4 25.0 3.56/4.24 A/A 3/8" - 3/4" 100/40 5.0/Calc. 400/3/50 2 Core Screened 16 1650x1100x390 170Sideflow VRF Heat
Pump R410a Inverter 3Ø Outdoor Unit
£5,091
RAS-10FSNM 28.0 31.5 3.21/4.04 A/A 1/2" - 7/8" 100/40 5.5/Calc. 400/3/50 2 Core Screened 20 1650x1100x390 170Sideflow VRF Heat
Pump R410a Inverter 3Ø Outdoor Unit
£5,928
RAS-12FSNM 33.5 37.5 2.7/3.79 B/A 1/2" - 1 1/8" 100/40 6.5/Calc. 400/3/50 2 Core Screened 25 1650x1100x390 173Sideflow VRF Heat
Pump R410a Inverter 3Ø Outdoor Unit
£7,108
SET FREE
MINI
SET FREE
SIDE FLOW RAS-FSNM
RAS-FS(V)N(Y)E
29
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional
Charge (kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description 2 Pipe
List Price3 Pipe
List Price
RAS 8FSXN1E 22.4 25.0 7.71 - Refer to TC 1000/50 5.4/Calc. 400/3/50 2 Core Screened 16 1720x950x765 215 Set Free VRF Heat Pump R410a 3Ø Outdoor Unit £5,538 £5,538
RAS 10FSXN1E 28.0 31.5 7.45 - Refer to TC 1000/50 6.4/Calc. 400/3/50 2 Core Screened 20 1720x950x765 230 Set Free VRF Heat Pump R410a 3Ø Outdoor Unit £6,083 £6,083
RAS 12FSXN1E 33.5 37.5 7.08 - Refer to TC 1000/50 7.3/Calc. 400/3/50 2 Core Screened 32 1720x950x765 230 Set Free VRF,R410a 3Ø Outdoor Unit £7,377 £7,377
RAS 14FSXN1E 40.0 45.0 6.17 - Refer to TC 1000/50 8.5/Calc. 400/3/50 2 Core Screened 32 1720x1210x765 310 Set Free VRF,R410a 3Ø Outdoor Unit £8,697 £8,697
RAS 16FSXN1E 45.0 50.0 6.06 - Refer to TC 1000/50 9.5/Calc 400/3/50 2 Core Screened 40 1720x1210x765 310 Set Free VRF,R410a 3Ø Outdoor Unit £10,249 £10,249
RAS 16FSXN1E-P 45.0 50.0 7.56 8+10 Refer to TC 1000/50 11.8/Calc. 400/3/50 2 Core Screened 16+20 1720x1920x765 445Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£11,816 £11,912
RAS 18FSXN1E 50.0 56.0 7.56 8+10 Refer to TC 1000/50 11.8/Calc. 400/3/50 2 Core Screened 16+20 1720x1920x765 445Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£11,816 £11,912
RAS 20FSXN1E 56.0 63.0 7.22 8+12 Refer to TC 1000/50 12.7/Calc. 400/3/50 2 Core Screened 16+32 1720x1920x765 445Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£13,110 £13,206
RAS 22FSXN1E 61.5 69.0 6.7 8+14 Refer to TC 1000/50 13.9/Calc. 400/3/50 2 Core Screened 16+32 1720x2180x765 525Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£14,430 £14,526
RAS 24FSXN1E 69.0 77.5 6.59 10+14 Refer to TC 1000/50 14.9/Calc. 400/3/50 2 Core Screened 20+32 1720x2180x765 540Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£14,975 £15,071
RAS 26FSXN1E 73.0 82.5 6.58 12+14 Refer to TC 1000/50 15.8/Calc. 400/3/50 2 Core Screened 32+32 1720x2180x765 540Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£16,379 £16,473
RAS 28FSXN1E 80.0 90.0 6.17 14+14 Refer to TC 1000/50 17.0/Calc. 400/3/50 2 Core Screened 32+32 1720x2440x765 620Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£17,699 £17,793
RAS 30FSXN1E 85.0 95.0 6.12 14+16 Refer to TC 1000/50 18.0/Calc. 400/3/50 2 Core Screened 32+40 1720x2440x765 620Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£19,251 £19,345
RAS 32FSXN1E 90.0 100.0 6.06 16+16 Refer to TC 1000/50 19.0/Calc. 400/3/50 2 Core Screened 40+40 1720x2440x765 620Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£20,803 £20,897
RAS 32FSXN1E-P 90.0 100.0 7.17 10+12+12 Refer to TC 1000/50 21.0/Calc. 400/3/50 2 Core Screened 20+32+32 1720x2890x765 690Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£21,450 £21,708
RAS 34FSXN1E 95.0 106.0 7.11 10+12+12 Refer to TC 1000/50 21.0/Calc. 400/3/50 2 Core Screened 20+32+32 1720x2890x765 690Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£21,450 £21,708
RAS 36FSXN1E 100.0 112.0 7.1 12+12+12 Refer to TC 1000/50 21.9/Calc. 400/3/50 2 Core Screened 32+32+32 1720x2890x765 690Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£22,744 £23,002
SET FREE / MODULAR:
STANDARD
CONTINUED...
RAS-FSXN1E
30
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional
Charge (kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating (A)
Dimensions (HxWxD)
mm
Weight (kg) Description 2 Pipe
List Price3 Pipe
List Price
RAS 38FSXN1E 109.0 118.0 6.59 12+12+14 Refer to TC 1000/50 23.1/Calc. 400/3/50 2 Core Screened 32+32+32 1720x3150x765 770Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£24,064 £24,322
RAS 40FSXN1E 112.0 125.0 6.62 12+12+16 Refer to TC 1000/50 24.1/Calc. 400/3/50 2 Core Screened 32+32+40 1720x3150x765 770Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£25,616 £25,874
RAS 42FSXN1E 118.0 132.0 6.38 12+14+16 Refer to TC 1000/50 25.3/Calc. 400/3/50 2 Core Screened 32+32+40 1720x3410x765 850Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£26,936 £27,194
RAS 44FSXN1E 125.0 140.0 5.97 12+16+16 Refer to TC 1000/50 26.3/Calc. 400/3/50 2 Core Screened 32+40+40 1720x3410x765 850Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£28,488 £28,746
RAS 46FSXN1E 132.0 145.0 6.02 14+16+16 Refer to TC 1000/50 27.5/Calc. 400/3/50 2 Core Screened 32+40+40 1720x3670x765 930Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£29,808 £30,066
RAS 48FSXN1E 136.0 150.0 6.04 16+16+16 Refer to TC 1000/50 28.5/Calc. 400/3/50 2 Core Screened 40+40+40 1720x3670x765 930Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£31,360 £31,618
RAS 50FSXN1E 140.0 155.0 6.64 10+12+14+14 Refer to TC 1000/50 30.7/Calc. 400/3/50 2 Core Screened 20+32+32+32 1720x4380x765 1080Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£31,500 £31,725
RAS 52FSXN1E 145.0 160.0 6.62 12+12+14+14 Refer to TC 1000/50 31.6/Calc. 400/3/50 2 Core Screened 32+32+32+32 1720x4380x765 1080Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£32,794 £33,019
RAS 54FSXN1E 150.0 165.0 6.58 12+12+14+16 Refer to TC 1000/50 32.6/Calc. 400/3/50 2 Core Screened 32+32+32+40 1720x4380x765 1080Set Free VRF, R410a 3Ø
Outdoor Unit (Inc. Modular Connection Kit)
£34,346 £34,571
SET FREE / MODULAR:
STANDARD
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional
Charge (kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description 2 Pipe
List Price3 Pipe
List Price
RAS 5FSXNHE 14.0 16.0 8.4 - Refer to TC 1000/50 5.6/Calc. 400/3/50 2 Core Screened 16 1720x950x765 215High Efficiency Set Free VRF R410a 3Ø Outdoor
Unit£4,472 £4,472
RAS 6FSXNHE 16.0 18.0 8.53 - Refer to TC 1000/50 6.6/Calc. 400/3/50 2 Core Screened 16 1720x950x765 215High Efficiency Set Free VRF R410a 3Ø Outdoor
Unit£5,260 £5,260
RAS 8FSXNHE 22.4 25.0 8.72 - Refer to TC 1000/50 7.7/Calc. 400/3/50 2 Core Screened 16 1720x1210x765 260High Efficiency Set Free VRF R410a 3Ø Outdoor
Unit£5,980 £5,980
SET FREE / MODULAR:
HIGH EFFICIENCY
CONTINUED...
RAS-FSXNHE
31
Model No.Nominal
Cooling Capacity (Sens) kW
Nominal Heating
Capacity kW
Efficiency (SEER/SCOP)
Energy Rating
Pipe Sizes (Liquid - Gas)
Max Pipe Length/Height Difference (m)
Pre-Charge/ Additional
Charge (kg/g/m)
Power Supply
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD)
mm
Weight (kg) Description 2 Pipe
List Price3 Pipe
List Price
RAS 10FSXNHE 28.0 31.5 8.12 - Refer to TC 1000/50 7.7/Calc. 400/3/50 2 Core Screened 20 1720x1210x765 260High Efficiency Set Free VRF R410a 3Ø Outdoor
Unit£7,297 £7,297
RAS 12FSXNHE 33.5 37.5 7.35 - Refer to TC 1000/50 8.3/Calc. 400/3/50 2 Core Screened 25 1720x1210x765 260High Efficiency Set Free VRF, R410a 3Ø Outdoor
Unit£8,755 £8,755
RAS 12FSXNHE-P 33.5 37.5 8.79 6+8 Refer to TC 1000/50 13.3/Calc.. 400/3/50 2 Core Screened 16+16 1720x2180x765 475Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£11,435 £11,531
RAS 14FSXNHE 40.0 45.0 8.57 6+8 Refer to TC 1000/50 13.3/Calc.. 400/3/50 2 Core Screened 16+16 1720x2180x765 475Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£11,435 £11,531
RAS 16FSXNHE 45.0 50.0 8.7 8+8 Refer to TC 1000/50 15.4/Calc. 400/3/50 2 Core Screened 16+16 1720x2440x765 520Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£12,156 £12,252
RAS 18FSXNHE 50.0 56.0 8.38 8+10 Refer to TC 1000/50 15.5/Calc. 400/3/50 2 Core Screened 16+20 1720x2440x765 520Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£13,472 £13,568
RAS 20FSXNHE 56.0 63.0 7.84 8+12 Refer to TC 1000/50 16.0/Calc. 400/3/50 2 Core Screened 16+25 1720x2440x765 520Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£14,931 £15,027
RAS 22FSXNHE 61.5 69.0 7.69 10+12 Refer to TC 1000/50 16.0/Calc. 400/3/50 2 Core Screened 20+25 1720x2440x765 520Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£16,247 £16,343
RAS 24FSXNHE 69.0 77.5 7.32 12+12 Refer to TC 1000/50 16.6/Calc. 400/3/50 2 Core Screened 25+25 1720x2440x765 520Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£17,705 £17,801
RAS 24FSXNHE-P 69.0 77.5 8.68 8+8+10 Refer to TC 1000/50 23.0/Calc. 400/3/50 2 Core Screened 16+16+20 1720x3670x765 780Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£19,871 £20,129
RAS 26FSXNHE 73.0 82.5 8.48 8+8+10 Refer to TC 1000/50 23.0/Calc. 400/3/50 2 Core Screened 16+16+20 1720x3670x765 780Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£19,871 £20,129
RAS 28FSXNHE 80.0 90.0 8.05 8+8+12 Refer to TC 1000/50 23.7/Calc. 400/3/50 2 Core Screened 16+16+25 1720x3670x765 780Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£21,329 £21,587
RAS 30FSXNHE 85.0 95.0 7.93 8+10+12 Refer to TC 1000/50 23.7/Calc. 400/3/50 2 Core Screened 16+20+25 1720x3670x765 780Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£22,645 £22,903
RAS 32FSXNHE 90.0 100.0 7.65 8+12+12 Refer to TC 1000/50 24.3/Calc. 400/3/50 2 Core Screened 16+25+25 1720x3670x765 780Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£22,645 £24,362
RAS 34FSXNHE 95.0 106.0 7.58 10+12+12 Refer to TC 1000/50 24.3/Calc. 400/3/50 2 Core Screened 20+25+25 1720x3670x765 780Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£25,420 £25,678
RAS 36FSXNHE 100.0 112.0 7.35 12+12+12 Refer to TC 1000/50 24.9/Calc. 400/3/50 2 Core Screened 25+25+25 1720x3670x765 780Hi. Eff. Set Free VRF, R410a
3Ø Outdoor Unit (Inc. Modular Connection Kit)
£26,879 £27,137
SET FREE / MODULAR:
HIGH EFFICIENCY
32
Model No. Max No. of Indoor Units Dimensions (HxWxD) mm Weight (kg) Description Unit List Price
CH 6.0N2 7 191x301x214 7 R410a Changeover Box (0.6~6.0HP) £471
CH 10.0N2 8 191x301x214 7 R410a Changeover Box (6.1~10.0HP) (New) £589
SET FREE
CH BOXES CH-N2
INSTALL SET FREE FSXNH OR FSXN1E FOR FLEXIBLE 2-PIPE HEAT PUMP OR 3-PIPE HEAT RECOVERY FROM A SINGLE, COMPACT MODULAR UNIT WHEN COMBINED WITH HITACHI’S CH BOXES.
SYSTEM FREECOMBINE SYSTEM FREE INDOOR UNITS WITH EITHER UTOPIA SPLIT SYSTEMS OR
SET FREE VRF RANGES FOR ULTIMATE SCOPE AND INSTALLATION FLEXIBILITY.
CASSETTES / P.34-37WALL MOUNTED / P.38
DUCTED/ P.39-40FLOOR MOUNTED / P.41
33
34
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RCI 1.0FSN4 2.5 2.8 2.8 3.2 1/4" - 1/2" 27/28/30/33 9/11/13/15 230/1/50 2 Core Screened 5 248x840x840 20 4-Way Blow Cassette (Excluding Air Panel) £598
RCI 1.5(1.3)FSN4 3.2 3.6 3.8 4.2 1/4" - 1/2" 27/30/31/35 11/14/17/21 230/1/50 2 Core Screened 5 248x840x840 21 4-Way Blow Cassette (Excluding Air Panel) £615
RCI 1.5FSN4 3.6 4.0 4.0 4.8 1/4" - 1/2" 27/30/31/35 11/14/17/21 230/1/50 2 Core Screened 5 248x840x840 21 4-Way Blow Cassette (Excluding Air Panel) £615
RCI 2.0(1.8)FSN4 4.5 5.0 5.2 5.6 1/4" - 1/2" 27/30/32/37 11/14/17/22 230/1/50 2 Core Screened 5 248x840x840 21 4-Way Blow Cassette (Excluding Air Panel) £666
RCI 2.0FSN4 5.0 5.6 5.6 6.3 1/4" - 1/2" 27/30/32/37 11/14/17/22 230/1/50 2 Core Screened 5 248x840x840 21 4-Way Blow Cassette (Excluding Air Panel) £666
RCI 2.5(2.3)FSN4 5.1 5.7 6.7 7.5 3/8" - 5/8" 28/32/36/42 14/18/23/27 230/1/50 2 Core Screened 5 248x840x840 22 4-Way Blow Cassette (Excluding Air Panel) £705
RCI 2.5FSN4 5.6 6.3 7.1 8.5 3/8" - 5/8" 28/32/36/42 14/18/23/27 230/1/50 2 Core Screened 5 248x840x840 22 4-Way Blow Cassette (Excluding Air Panel) £705
RCI 3.0FSN4 7.1 8.0 8.0 9.0 3/8" - 5/8" 28/32/36/42 14/18/23/27 230/1/50 2 Core Screened 5 298x840x840 26 4-Way Blow Cassette (Excluding Air Panel) £731
RCI 4.0FSN4 10.0 11.2 11.2 12.5 3/8" - 5/8" 33/39/43/48 20/24/31/37 230/1/50 2 Core Screened 5 298x840x840 26 4-Way Blow Cassette (Excluding Air Panel) £813
RCI 5.0FSN4 12.5 14.0 14.0 16.0 3/8" - 5/8" 35/40/45/48 21/26/33/37 230/1/50 2 Core Screened 5 298x840x840 26 4-Way Blow Cassette (Excluding Air Panel) £919
RCI 6.0FSN4 14.0 16.0 16.0 18.0 3/8" - 5/8" 37/41/46/48 22/28/35/37 230/1/50 2 Core Screened 5 298x840x840 26 4-Way Blow Cassette (Excluding Air Panel) £1,095
P-N23NA2 40x950x950 6.5 Air Panel for RCI-FSN4 £223
Accessories
Model No. Description List Price
PS-MSK2 Motion Sensor Kit £82
OACI-160K2 Fresh Air Intake Kit (RCI 1.0 ~ 6.0FSN3Ei) £423
PD-75A Fresh Air Intake Kit (75mm Ø, Max 10% Air Volume) £125
PC-ALH3 Fascia Panel Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3B) £147
PC-ALHZF Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3B) £133
PC-LH3B Wireless Remote Controller £90
SYSTEM FREE
4 WAY CASSETTE - RCI-FSN4 RCI-FSN4
New RCI.FSN4 cassette replaces the RCI.FSN3Ei,RCI.FSN3Ek and RCI.FSN3 from May 2017
35
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RCIM 0.6FSN4 - 1.7 - 1.9 1/4" - 1/2" 24.5/28/30/34 6/7.5/8.5/10 230/1/50 2 Core Screened 5 285x570x570 16Mini 4-Way Blow Cassette
(Excluding Air Panel) (Only with Set Free FSXN1E & FSXNHE)
£641
RCIM 0.8FSN4 2.0 2.2 2.2 2.5 1/4" - 1/2" 24.5/29/33/36 6/8/9.5/11 230/1/50 2 Core Screened 5 285x570x570 16 Mini 4-Way Blow Cassette (Excluding Air Panel) £656
RCIM 1.0FSN4 2.5 2.8 2.8 3.2 1/4" - 1/2" 24.5/30/34/38 6/8.5/10/12 230/1/50 2 Core Screened 5 285x570x570 16 Mini 4-Way Blow Cassette (Excluding Air Panel) £664
RCIM 1.5(1.3)FSN4 3.2 3.8 3.6 4.2 1/4" - 1/2" 27.5/33/37/41 7/9.5/11/13 230/1/50 2 Core Screened 5 285x570x570 16 Mini 4-Way Blow Cassette (Excluding Air Panel) £678
RCIM 1.5FSN4 3.6 4.0 4.0 4.8 1/4" - 1/2" 27.5/33/37/41 7/9.5/11/13 230/1/50 2 Core Screened 5 285x570x570 16 Mini 4-Way Blow Cassette (Excluding Air Panel) £678
RCIM 2.0(1.8)FSN4 4.5 5.2 5.0 5.6 1/4" - 1/2" 31/35/39/45 8/10/12/15 230/1/50 2 Core Screened 5 285x570x570 16 Mini 4-Way Blow Cassette (Excluding Air Panel) £734
RCIM 2.0FSN4 5.0 5.6 5.6 6.3 1/4" - 1/2" 31/35/39/45 8/10/12/15 230/1/50 2 Core Screened 5 285x570x570 17 Mini 4-Way Blow Cassette (Excluding Air Panel) £734
RCIM 2.5FSN4 5.6 6.3 7.1 8.5 3/8" - 5/8" 35/39/43/47 10/12/14/16 230/1/50 2 Core Screened 5 285x570x570 17 Mini 4-Way Blow Cassette (Excluding Air Panel) £796
P-AP56NAM 30x620x620 2.5 Air Panel for RCIM-FSN4 £190
Accessories
Model No. Description List Price
PD-75C Fresh Air Intake Kit (75mm Ø, Max 10% Air Volume) £116
SOR-NEC Motion Sensor Kit £218
PC-ALHC1 Fascia Panel Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3B) £127
PC-ALHZF Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3B) £133
PC-LH3B Wireless Remote Controller £90
PC-LH3B Wireless Remote Controller £90
SYSTEM FREE
MINI 4 WAY CASSETTE - RCIM-FSN4 RCIM-FSN4
36
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RCD 1.0FSN2 2.5 2.8 2.8 3.2 1/4" - 1./2" 30/32/34 8/9/10 230/1/50 2 Core Screened 5 298x860x620 272-Way Blow Cassette (Excluding Air Panel)
(Model Discontinued, Check Stock)£741
RCD 2.0(1.8)FSN2 4.5 5.2 5.0 5.6 1/4" - 5/8" 30/32/35 11/13/15 230/1/50 2 Core Screened 5 298x860x620 272-Way Blow Cassette (Excluding Air Panel)
(Model Discontinued, Check Stock)£874
RCD 2.0FSN2 5.0 5.6 5.6 6.3 1/4" - 5/8" 30/32/35 11/13/15 230/1/50 2 Core Screened 5 298x860x620 272-Way Blow Cassette (Excluding Air Panel)
(Model Discontinued, Check Stock)£874
RCD 2.5(2.3)FSN2 5.1 6.7 5.7 7.5 3/8" - 5/8" 31/34/38 14/16/19 230/1/50 2 Core Screened 5 298x860x620 302-Way Blow Cassette (Excluding Air Panel)
(Model Discontinued, Check Stock)£923
RCD 2.5FSN2 5.6 7.1 6.3 8.5 3/8" - 5/8" 31/34/38 14/16/19 230/1/50 2 Core Screened 5 298x860x620 302-Way Blow Cassette (Excluding Air Panel)
(Model Discontinued, Check Stock)£923
RCD 4.0FSN2 10.0 11.2 11.2 12.5 3/8" - 5/8" 33/36/40 21/24/29 230/1/50 2 Core Screened 5 298x1420x620 482-Way Blow Cassette (Excluding Air Panel)
(Model Discontinued, Check Stock)£1,140
RCD 5.0FSN2 12.5 14.0 14.0 16.0 3/8" - 5/8" 36/40/43 25/29/34 230/1/50 2 Core Screened 5 298x1420x620 482-Way Blow Cassette (Excluding Air Panel)
(Model Discontinued, Check Stock)£1,283
P-N23DNA 40x1100x710 6 Air Panel for RCD 1.0 ~ 3.0FSN2 £298
P-N46DNA 40x1660x710 8 Air Panel for RCD 4.0 ~ 5.0FSN2 £318
Accessories
Model No. Description List Price
PC-ALHD Fascia Panel Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3A) £105
PC-ALHZ Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3A) £124
PC-LH3A Wireless Remote Controller £90
SYSTEM FREE
2 WAY CASSETTE - STANDARD - RCD-FSN2 RCD-FSN2
37
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RCD 0.8FSN3 2.0 2.2 2.2 2.5 1/4" - 1/2" 27/28/29/30 6.5/7.5/9/10 230/1/50 2 Core Screened 5 345x860x630 23 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £735
RCD 1.0FSN3 2.5 2.8 2.8 3.2 1/4" - 1/2" 27/28/29/31 7/8.5/9.5/11 230/1/50 2 Core Screened 5 345x860x630 23 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £741
RCD 1.5(1.3)FSN3 3.2 3.8 3.6 4.2 1/4" - 1/2" 30/31/34/37 10/11.5/13/15 230/1/50 2 Core Screened 5 345x860x630 25 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £805
RCD 1.5FSN3 3.6 4.0 4.0 4.8 1/4" - 1/2" 30/31/34/37 10/11.5/13/15 230/1/50 2 Core Screened 5 345x860x630 25 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £805
RCD 2.0(1.8)FSN3 4.5 5.2 5.0 5.6 1/4" - 1/2" 30/33/36/39 10.5/12.5/14.5/16.5 230/1/50 2 Core Screened 5 345x860x630 25 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £874
RCD 2.0FSN3 5.0 85.6 5.6 6.3 1/4" - 1/2" 30/33/36/39 10.5/12.5/14.5/16.5 230/1/50 2 Core Screened 5 345x860x630 25 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £874
RCD 2.5(2.3)FSN3 5.1 6.7 5.7 7.5 3/8" - 5/8" 33/36/39/42 12.5/14.5/16.5/18.5 230/1/50 2 Core Screened 5 345x860x630 25 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £923
RCD 2.5FSN3 5.6 7.1 6.3 8.5 3/8" - 5/8" 33/36/39/42 12.5/14.5/16.5/18.5 230/1/50 2 Core Screened 5 345x860x630 25 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £923
RCD 3.0FSN3 7.1 8.0 8.0 9.0 3/8" - 5/8" 33/38/42/45 12.5/16/18.5/21 230/1/50 2 Core Screened 5 345x860x630 25 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £1,031
RCD 4.0FSN3 10.0 11.2 11.2 12.5 3/8" - 5/8" 34/37/40/43 20/23/26.5/30 230/1/50 2 Core Screened 5 345x1420x630 39 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £1,140
RCD 5.0FSN3 12.5 14.0 14.0 16.0 3/8" - 5/8" 35/41/44/47 21/27/31/35 230/1/50 2 Core Screened 5 345x1420x630 39 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £1,283
RCD 6.0FSN3 14.0 16.0 16.0 18.0 3/8" - 5/8" 39/42/45/48 24/28.5/32.5/37 230/1/50 2 Core Screened 5 345x1420x630 39 High Efficiency 2-Way Blow Cassette (Excluding Air Panel) £1,426
P-AP90DNA 30x1100x710 7.5 Air Panel for RCD 0.8 ~ 3.0FSN3 £302
P-AP160DNA 30x1660x710 10.5 Air Panel for RCD 4.0 ~ 6.0FSN3 £323
Accessories
Model No. Description List Price
SOR-NED Motion Sensor Kit £218
PC-ALHD1 Fascia Panel Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3B) £318
PC-ALHZF Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3B) £133
PC-LH3B Wireless Remote Controller £90
SYSTEM FREE
2 WAY CASSETTE - HIGH EFFICIENCY - RCD-FSN3 RCD-FSN3
38
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RPK 0.6FSN3M - 1.7 - 1.9 1/4" - 1/2" 29/31/32/35 6/7/7.5/8 230/1/50 2 Core Screened 5 300x790x230 10 Wall Mounted (Only with Set Free FSXN1E & FSXNHE) £476
RPK 0.8FSN3M 2.0 2.2 2.2 2.5 1/4" - 1/2" 30/32/35/39 6.5/7/8/10 230/1/50 2 Core Screened 5 300x790x230 10 Wall Mounted £486
RPK 1.0FSN3M 2.5 2.8 2.8 3.2 1/4" - 1/2" 30/32/35/39 6.5/7/8/10 230/1/50 2 Core Screened 5 300x790x230 10 Wall Mounted £497
RPK 1.5(1.3)FSN3M 3.2 3.8 3.6 4.2 1/4" - 1/2" 33/36/40/46 7.5/9/11/14 230/1/50 2 Core Screened 5 300x900x230 11 Wall Mounted £507
RPK 1.5FSN3M 3.6 4.0 4.0 4.8 1/4" - 1/2" 33/36/40/46 7.5/9/11/14 230/1/50 2 Core Screened 5 300x900x230 11 Wall Mounted £507
RPK 2.0(1.8)FSN3M 4.5 5.2 5.0 5.6 1/4" - 5/8" 33/38/40/42 10/13/14/15 230/1/50 2 Core Screened 5 333x1150x245 17 Wall Mounted £761
RPK 2.0FSN3M 5.0 5.6 5.6 6.3 1/4" - 5/8" 33/38/40/42 10/13/14/15 230/1/50 2 Core Screened 5 333x1150x245 17 Wall Mounted £761
RPK 2.5(2.3)FSN3M 5.1 6.5 5.7 7.8 3/8" - 5/8" 36/40/43/49 12/14/17/19 230/1/50 2 Core Screened 5 333x1150x245 18 Wall Mounted £762
RPK 2.5FSN3M 5.6 7.1 6.3 8.5 3/8" - 5/8" 36/40/43/49 12/14/17/19 230/1/50 2 Core Screened 5 333x1150x245 18 Wall Mounted £762
RPK 3.0FSN3M 7.1 8.0 8.0 9.0 3/8" - 5/8" 36/40/43/49 14/14/17/19 230/1/50 2 Core Screened 5 333x1150x245 18 Wall Mounted £796
RPK 4.0FSN3M 10.0 11.2 11.2 12.5 3/8" - 5/8" 41/46/49/51 15/17/19/22 230/1/50 2 Core Screened 5 333x1150x245 18 Wall Mounted £893
Accessories
Model No. Description List Price
PC-LH3A Wireless Remote Controller £90
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RPK 0.6FSNH3M - 1.7 - 1.9 1/4" - 1/2" 29/31/32/35 6/7/7.5/8 230/1/50 2 Core Screened 5 300x790x230 10Wall Mounted (Only with
Set Free FSXN1E & FSXNHE), (Requires EV1.5N)
£341
RPK 0.8FSNH3M 2.0 2.2 2.2 2.5 1/4" - 1/2" 30/32/35/39 6.5/7/8/10 230/1/50 2 Core Screened 5 300x790x230 10 Wall Mounted (Requires EV1.5N) £349
RPK 1.0FSNH3M 2.5 2.8 2.8 3.2 1/4" - 1/2" 30/32/35/39 6.5/7/8/10 230/1/50 2 Core Screened 5 300x790x230 10 Wall Mounted (Requires EV1.5N) £368
RPK 1.5(1.3)FSNH3M 3.2 3.8 3.6 4.2 1/4" - 1/2" 33/36/40/46 7.5/9/11/14 230/1/50 2 Core Screened 5 300x900x230 11 Wall Mounted (Requires EV1.5N) £384
RPK 1.5FSNH3M 3.6 4.0 4.0 4.8 1/4" - 1/2" 33/36/40/46 7.5/9/11/14 230/1/50 2 Core Screened 5 300x900x230 11 Wall Mounted (Requires EV1.5N) £384
RPK 2.0(1.8)FSN3M 164x109x201 1.5 Electronic Expansion Valve (RPK 0.6 ~ 1.5FSNH3M Only) £139
Accessories
Model No. Description List Price
PC-LH3A Wireless Remote Controller £90
SYSTEM FREE
WALL MOUNTED - RPK-FSN3(H)M
WALL MOUNTED (REMOTE EXPANSION VALVE)
RPK-FSN3M
39
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RPIM 0.6FSN4E - 1.7 - 1.9 1/4" - 1/2" 25/28/28 5.5/6.2/7 - 20 230/1/50 2 Core Screened 5 275x702x600 26Slim Width Ducted - (No Lift Pump),
(Only with Set Free FSXN1E & FSXNHE)
£538
RPIM 0.8FSN4E 2.0 2.2 2.2 2.5 1/4" - 1/2" 27/29/29 5.5/6.8/8 - 32 230/1/50 2 Core Screened 5 275x702x600 26 Slim Width Ducted (No Lift Pump) £550
RPIM 1.0FSN4E 2.5 2.8 2.8 3.2 1/4" - 1/2" 27/29/29 5.5/6.8/8 - 32 230/1/50 2 Core Screened 5 275x702x600 26 Slim Width Ducted (No Lift Pump) £572
RPIM 1.5(1.3)FSN4E 3.2 3.8 3.6 4.2 1/4" - 1/2" 28/30/30 8/9/10 - 27 230/1/50 2 Core Screened 5 275x702x600 26 Slim Width Ducted (No Lift Pump) £614
RPIM 1.5FSN4E 3.6 4.0 4.0 4.8 1/4" - 1/2" 28/30/30 8/9/10 - 27 230/1/50 2 Core Screened 5 275x702x600 26 Slim Width Ducted (No Lift Pump) £614
Accessories
Model No. Description List Price
PC-ALHZ Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3A) £124
PC-LH3A Wireless Remote Controller £90
DU-1ME Drain Pump Kit (RPIM-FSN4E) £89
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RPIM 0.6FSN4E-DU - 1.7 - 1.9 1/4" - 1/2" 25/28/28 5.5/6.2/7 - 20 230/1/50 2 Core Screened 5 275x702x600 26Slim Width Ducted (Includes
Lift Pump), (Only with Set Free FSXN1E & FSXNHE)
£667
RPIM 0.8FSN4E-DU 2.0 2.2 2.2 2.5 1/4" - 1/2" 27/29/29 5.5/6.8/8 - 32 230/1/50 2 Core Screened 5 275x702x600 26 Slim Width Ducted (Includes Lift Pump) £726
RPIM 1.0FSN4E-DU 2.5 2.8 2.8 3.2 1/4" - 1/2" 27/29/29 5.5/6.8/8 - 32 230/1/50 2 Core Screened 5 275x702x600 26 Slim Width Ducted (Includes Lift Pump) £754
RPIM 1.5(1.3)FSN4E-DU 3.2 3.8 3.6 4.2 1/4" - 1/2" 28/30/30 8/9/10 - 27 230/1/50 2 Core Screened 5 275x702x600 26 Slim Width Ducted (Includes Lift Pump) £799
RPIM 1.5FSN4E-DU 3.6 4.0 4.0 4.8 1/4" - 1/2" 28/30/30 8/9/10 - 27 230/1/50 2 Core Screened 5 275x702x600 26 Slim Width Ducted (Includes Lift Pump) £799
Accessories
Model No. Description List Price
PC-ALHZ Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3A) £124
PC-LH3A Wireless Remote Controller £90
SYSTEM FREE
DUCTED UNIT - SLIM WIDTH - RPIM-FSN4E(-DU)
SLIM WIDTH DUCTED UNIT
RPIM-FSN4E(-DU)
40
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RPI 0.6FSN4E - 1.7 - 1.9 1/4" - 1/2" 27/30/32 5.5/6.2/7 - 20 230/1/50 2 Core Screened 5 197x1084x600 29 Low Height Ducted (Only with Set Free FSXN1E & FSXNHE) £538
RPI 0.8FSN4E 2.0 2.2 2.2 2.5 1/4" - 1/2" 29/31/33 6.3/7.2/8 - 32 230/1/50 2 Core Screened 5 197x1084x600 29 Low Height Ducted £550
RPI 1.0FSN4E 2.5 2.8 2.8 3.2 1/4" - 1/2" 29/31/33 6.3/7.2/8 - 32 230/1/50 2 Core Screened 5 197x1084x600 29 Low Height Ducted £572
RPI 1.5(1.3)FSN4E 3.2 3.8 3.6 4.2 1/4" - 1/2" 29/31/34 8/9/10 - 27 230/1/50 2 Core Screened 5 197x1084x600 30 Low Height Ducted £614
RPI 1.5FSN4E 3.6 4.0 4.0 4.8 1/4" - 1/2" 29/31/34 8/9/10 - 27 230/1/50 2 Core Screened 5 197x1084x600 30 Low Height Ducted £614
RPI 2.0(1.8)FSN4E 4.5 5.2 5.0 5.6 1/4" - 5/8" 27/29/29 10/12.5/16 - 30 230/1/50 2 Core Screened 5 275x1084x600 35 Std. Ducted £673
RPI 2.0FSN4E 5.0 5.6 5.6 6.3 1/4" - 5/8" 27/29/29 10/12.5/16 - 30 230/1/50 2 Core Screened 5 275x1084x600 35 Std. Ducted £673
RPI 2.5(2.3)FSN4E 5.1 6.7 5.7 7.5 3/8" - 5/8" 28/30/30 13/16/19 - 30 230/1/50 2 Core Screened 5 275x1084x600 36 Std. Ducted £707
RPI 2.5FSN4E 5.6 7.1 6.3 8.5 3/8" - 5/8" 28/30/30 13/16/19 - 30 230/1/50 2 Core Screened 5 275x1084x600 36 Std. Ducted £707
RPI 3.0FSN4E 7.1 8.0 8.0 9.0 3/8" - 5/8" 29/31/31 16/19/22 - 30 230/1/50 2 Core Screened 5 275x1084x600 36 Std. Ducted £745
RPI 4.0FSN4E 10.0 11.2 11.2 12.5 3/8" - 5/8" 32/35/37 25/28/30 - 45 230/1/50 2 Core Screened 5 275x1474x600 48 Std. Ducted £844
RPI 5.0FSN4E 12.5 14.0 14.0 16.0 3/8" - 5/8" 33/35/38 29/32/35 - 50 230/1/50 2 Core Screened 5 275x1474x600 48 Std. Ducted £942
RPI 6.0FSN4E 14.0 16.0 16.0 18.0 3/8" - 5/8" 33/36/39 30/33/36 - 50 230/1/50 2 Core Screened 5 275x1474x600 48 Std. Ducted £1,115
RPI 8.0FSN3E 20.0 22.4 22.4 25.0 3/8" - 3/4" 51/54/54 59.5/66/66 - 220 230/1/50 2 Core Screened 10 423x1592x600 85 Std. Ducted £1,638
RPI 10.0FSN3E 25.0 28.0 28.0 31.0 3/8" - 7/8" 52/55/55 67.6/75/75 - 220 230/1/50 2 Core Screened 10 423x1592x600 87 Std. Ducted £1,764
RPI 16.0FSN3PE - 45.0 - 50.0 2 x 3/8" - 2 x 3/4" 53/-/56 119/-/132
- 180 230/1/50 2 Core Screened 25 846x1592x600 171 High Capacity Ducted (Only with Modular Set Free) £3,299
RPI 20.0FSN3PE - 56.0 - 63.0 2 x 3/8" - 2 x 7/8" 54/-/57 135/-/150
- 180 230/1/50 2 Core Screened 25 846x1592x600 175 High Capacity Ducted (Only with Modular Set Free) £3,542
Accessories
Model No. Description List Price
PC-ALHZ Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3A) £124
PC-LH3A Wireless Remote Controller £90
SYSTEM FREE
LOW HEIGHT/STANDARD DUCTED UNITS - RPI-FSN3/4E RPI-FSN4ERPI-FSN3E
41
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RPFI 1.0FSN2E 2.5 2.8 2.8 3.2 1/4" - 1/2" 29/32/35 6/7/8.5 230/1/50 2 Core Screened 5 620x848x220 19 Floor Mounted - Uncased £643
RPFI 1.5(1.3)FSN2E 3.2 3.8 3.6 4.2 1/4" - 1/2" 31/35/38 9/10/12 230/1/50 2 Core Screened 5 620x973x220 23 Floor Mounted - Uncased £660
RPFI 1.5FSN2E 3.6 4.0 4.0 4.8 1/4" - 1/2" 31/35/38 9/10/12 230/1/50 2 Core Screened 5 620x973x220 23 Floor Mounted - Uncased £660
RPFI 2.0(1.8)FSN2E 4.5 5.2 5.0 5.6 1/4" - 5/8" 32/36/39 11/14/16 230/1/50 2 Core Screened 5 620x1223x220 27 Floor Mounted - Uncased £776
RPFI 2.0FSN2E 5.0 5.6 5.6 6.3 1/4" - 5/8" 32/36/39 11/14/16 230/1/50 2 Core Screened 5 620x1223x220 27 Floor Mounted - Uncased £776
RPFI 2.5(2.3)FSN2E 5.1 6.7 5.7 7.5 3/8" - 5/8" 34/38/42 11/14/16 230/1/50 2 Core Screened 5 620x1223x220 28 Floor Mounted - Uncased £823
RPFI 2.5FSN2E 5.6 7.1 6.3 8.5 3/8" - 5/8" 34/38/42 11/14/16 230/1/50 2 Core Screened 5 620x1223x220 28 Floor Mounted - Uncased £823
Accessories
Model No. Description List Price
PC-ALHZ Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3A) £124
PC-LH3A Wireless Remote Controller £90
Model No.Nominal Cooling Capacity kW Nominal Heating Capacity kW Pipe Sizes
(Liquid - Gas)Sound Pressure (dB(A) (L/M/H)
Airflow m3/min (L/M/H)
Power Supply
(v/ph/Hz)
Interconnecting Cables
Suggested Fuse Rating
(A)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
PriceUtopia Set Free Utopia Set Free
RPF 1.0FSN2E 2.5 2.8 2.8 3.2 1/4" - 1/2" 29/32/35 6/7/8.5 230/1/50 2 Core Screened 5 630x1045x220 25 Floor Mounted - Cased £708
RPF 1.5(1.3)FSN2E 3.2 3.8 3.6 4.2 1/4" - 1/2" 31/35/38 9/10/12 230/1/50 2 Core Screened 5 630x1170x220 28 Floor Mounted - Cased £730
RPF 1.5FSN2E 3.6 4.0 4.0 4.8 1/4" - 1/2" 31/35/38 9/10/12 230/1/50 2 Core Screened 5 630x1170x220 28 Floor Mounted - Cased £730
RPF 2.0(1.8)FSN2E 4.5 5.2 5.0 5.6 1/4" - 5/8" 32/36/39 11/14/16 230/1/50 2 Core Screened 5 630x1420x220 33 Floor Mounted - Cased £799
RPF 2.0FSN2E 5.0 5.6 5.6 6.3 1/4" - 5/8" 32/36/39 11/14/16 230/1/50 2 Core Screened 5 630x1420x220 33 Floor Mounted - Cased £799
RPF 2.5(2.3)FSN2E 5.1 6.7 5.7 7.5 3/8" - 5/8" 34/38/42 11/14/16 230/1/50 2 Core Screened 5 630x1420x220 34 Floor Mounted - Cased £851
RPF 2.5FSN2E 5.6 7.1 6.3 8.5 3/8" - 5/8" 34/38/42 11/14/16 230/1/50 2 Core Screened 5 630x1420x220 34 Floor Mounted - Cased £851
Accessories
Model No. Description List Price
PC-ALHZ Wall Mounted Receiver Kit (Enables Infra Red Remote Control With PC-LH3A) £124
PC-LH3A Wireless Remote Controller £90
SYSTEM FREE
FLOOR MOUNTED UNCASED - RPFI FSN2E
SYSTEM FREE
FLOOR MOUNTED CASED - RPF-FSN2E
RPFI-FSN2E
RPF-FSN2E
VENTILATIONHITACHI’S VENTILATION PRODUCT RANGE ENSURES A STABLE INDOOR TEMPERATURE, SAVES ENERGY AND
PROVIDES FREE COOLING WHERE COOLING DEMAND IS GENERALLY HIGH ALL YEAR.
KPI ENERGY RECOVERY / P.43-44ECONOFRESH / P.43KPI ACTIVE / P.44
42
43
Model No. Sound Pressure (dB(A) (L/M/H)
Airflow m3/hr (L/M/H)
Maximum External Static Pressure (Pa)
Temperature Exchange Efficiency (L/M/H) %
Duct Connection Diameter (mm)
Dimensions (Hx-WxD) mm Weight (kg) Description Unit List
Price
KPI-252E4E 25/27/28 180/208/250 240 79/77/74 160 270x900x750 34 Energy Recovery Ventilation, inc. ErP Lot 11 compliant DC Fans £748
KPI-502E4E 30/31/33 360/420/500 210 78/77/74 200 330x1130x920 46 Energy Recovery Ventilation, inc. ErP Lot 11 compliant DC Fans £1,214
KPI-802E4E 33/34/35 540/650/800 120 78/76/75 250 385x1210x1015 51 Energy Recovery Ventilation, inc. ErP Lot 11 compliant DC Fans £1,778
KPI-1002E4E 32/34/37 620/800/1000 190 83/81/78 300 385x1600x1295 79 Energy Recovery Ventilation, inc. ErP Lot 11 compliant DC Fans £2,051
KPI-1502E4E 35/37/39 950/1250/1500 180 80/76/73 355 525x1800x1130 97 Energy Recovery Ventilation, inc. ErP Lot 11 compliant DC Fans £2,996
KPI-2002E4E 36/39/40 1200/1450/2000 170 80/78/76 355 525x1800x1430 106 Energy Recovery Ventilation, inc. ErP Lot 11 compliant DC Fans £3,682
Accessories
Model No. Description List Price
HEF-252 High Efficiency Filter ( Classified as F7 based on EN779) - KPI 252E4E £65
HEF-502 High Efficiency Filter ( Classified as F7 based on EN779) - KPI 502E4E £129
HEF-802 High Efficiency Filter ( Classified as F7 based on EN779) - KPI 802E4E £137
HEF-1002 High Efficiency Filter ( Classified as F7 based on EN779) - KPI 1001E4E £143
HEF-1502 High Efficiency Filter ( Classified as F7 based on EN779)KPI 1502E4E £153
HEF-2002 High Efficiency Filter ( Classified as F7 based on EN779) - KPI 2002E4E £183
STL-30-200-L600 Ductwork Sound Attenuator - KPI-502E4E £229
STL-30-250-L600 Ductwork Sound Attenuator - KPI-802E4E £276
STL-30-300-L600 Ductwork Sound Attenuator - KPI-1002E4E £298
STL-30-355-L600 Ductwork Sound Attenuator - KPI-1502 ~ 2002E4E £313
VENTILATION
KPI ENERGY RECOVERY KPI-E4E
Model No. Dimensions (HxWxD) mm Weight (kg) Description Unit List Price
EF 456NE 254x1350x270 12.5 Econofresh Kit (For installation with RPI 4.0/5.0/6.0FSN4E) £761
VENTILATION
ECONOFRESH EF-NE
44
Model No. Nominal Cooling Capacity (kW)
Nominal Heating Capacity kW
Sound Pressure (dB(A) (L/M/H)
Airflow m3/hr (L/M/H)
Maximum External Static Pressure (Pa)
Temperature Exchange
Efficiency (L/M/H) %
Duct Connection Diameter (mm)
Dimensions (HxWxD) mm
Weight (kg) Description Unit List
Price
KPI-502X4E 5.32 (1.81) 6.92 (2.12) 29/30/32 380/430/500 165 74/77/78 200 330x1435x920 62 Energy recovery Ventilation + DX Coil (Set Free 1.5hp) - inc. ErP Lot 11 compliant DC Fans £2,643
KPI-802X4E 7.96 (2.94) 9.79 (3.49) 32/33/34 590/700/800 110 75/76/78 250 385x1513x1015 69 Energy recovery Ventilation + DX Coil (Utopia/Set Free 2.0hp) - inc. ErP Lot 11 compliant DC Fans £3,123
KPI-1002X4E 10.83 (3.73) 12.93 (4.43) 31/33/36 740/820/1000 170 78/81/83 300 385x1904x1295 100 Energy recovery Ventilation + DX Coil (Utopia/Set Free 2.5hp) - inc. ErP Lot 11 compliant DC Fans £3,644
Accessories
Model No. Description List Price
HEF-502 High Efficiency Filter ( Classified as F7 based on EN779) - KPI 502X4E £129
HEF-802 High Efficiency Filter ( Classified as F7 based on EN779) - KPI 802X4E £137
HEF-1002 High Efficiency Filter ( Classified as F7 based on EN779) - KPI 1002X4E £143
STL-30-200-L600 Ductwork Sound Attenuator - KPI-502X4E £229
STL-30-300-L600 Ductwork Sound Attenuator - KPI-802X4E £298
STL-30-355-L600 Ductwork Sound Attenuator - KPI-1002X4E £313
VENTILATION
KPI ACTIVE
Values in brackets represent the heat recovery capacity.
KPI-X4E
Model No. Model No. Control Box Dimensions (HxWxD) mm Control Box Weight (kg) Expansion Valve Dimensions (HxWxD) mm Expansion Valve Weight (kg) Description Unit List
Price
EXV-2.0E2 291x341x127 3 431x199x103 2 DX Interface Kit (2HP) (Inlet/Outlet Temp, 0-10V,4-20mA Control) £129
EXV-2.5E2 291x341x127 3 431x199x103 3 DX Interface Kit (2.5HP) (Inlet/Outlet Temp, 0-10V,4-20mA Control) £129
EXV-3.0E2 291x341x127 3 431x199x103 3 DX Interface Kit (3HP) (Inlet/Outlet Temp, 0-10V,4-20mA Control) £129
EXV-4.0E2 291x341x127 3 431x199x103 3 DX Interface Kit (4HP) (Inlet/Outlet Temp, 0-10V,4-20mA Control) £129
EXV-5.0E2 291x341x127 3 431x199x103 3 DX Interface Kit (5HP) (Inlet/Outlet Temp, 0-10V,4-20mA Control) £129
EXV-6.0E2 291x341x127 3 431x199x103 3 DX Interface Kit (6HP) (Inlet/Outlet Temp, 0-10V,4-20mA Control) £129
EXV-8.0E2 291x341x127 3 431x199x103 5 DX Interface Kit (8HP) (Inlet/Outlet Temp, 0-10V,4-20mA Control) £129
EXV-10.0E2 291x341x127 3 431x199x103 5 DX Interface Kit (10HP) (Inlet/Outlet Temp, 0-10V,4-20mA Control) £129
VENTILATION
DX KITS EXV-E2
CONTROL SYSTEMSA WIDE RANGE OF CONTROL SYSTEMS TO ENABLE INTELLIGENT MANAGEMENT
OF HITACHI PRODUCTS AND ASSOCIATED SYSTEMS
CONTROLS AND ACCESSORIES / P.46SYSTEM FREE ACCESSORIES / P.47
RENEWAL KITS / P.48DOOR CURTAINS / P.49
45
46
Model No. Description Unit List Price
PC-ARH Simplified Wired Remote Controller £73
PC-ARFPE LCD Advanced Wired Remote Controller with 7 Day Timer £101
PC-LH3A Wireless Remote Controller (For compatibility see Technical Catalogue) £90
PC-LH3B Wireless Remote Controller (For compatibility see Technical Catalogue) £90
PSC-A64GT Touch Screen Central Controller (64 Zones) £1,920
PSC-A32MN Touch Screen Central Controller (32 Zones) £1,177
PSC-A64S Central Station (64 zones) £613
PSC-A1T 7 Day Timer for Central Station £212
PCS-A16RS Centralised On-Off Control Switch (16 Zones) £582
PSC-A160WEB1 Web Based Central Controller with Modbus Interface £2,698
CSNET Manager LT Touch Screen Central Controller (12" Screen), Internet connectable with HC-A64NET £2,222
CSNET Manager XT Touch Screen Central Controller (17" Screen), Internet connectable with HC-A64NET £3,605
Wall Mounted Support Wall Support For CSNET Manager LT/XT £51
Stand Mounted Support Desk Stand For CSNET Manager LT/XT £112
NET CONFIG KIT Net configuration kit for HC-A(8/64)MB and HC-A64NET £51
HC-A64NET Modbus BMS Interface (Control/Monitor 32 System Free Indoor Units) £680
HC-A8MB - MODBUS Modbus BMS Interface (Control/Monitor 8 System Free Indoor Units) £339
HC-A32MB - MODBUS Modbus BMS Interface (Control/Monitor 32 System Free Indoor Units) £1,277
HC-A64MB - MODBUS Modbus BMS Interface (Control/Monitor 64 System Free Indoor Units) £1,265
HC-A16KNX KNX BMS Interface (Control/Monitor 16 System Free Indoor Units) £1,283
KNX0001 KNX BMS Interface (Control/Monitor 128 System Free Indoor Units) £1,283
PC-A1IO Input/Output Interface for the CSNet Web £680
HARC-BXE (A/B) LonWorks BMS Interface (Control/Monitor 64(A) or 32(B) System Free IU) £3,972
PSC 5HR H-Link Relay £1,155
PCC-1A (5x) 3-Wire Adaptor for Remote Optional Functions £17
THM-R2AE Remote Thermistor (Loose) £21
CONTROL SYSTEMS
CONTROLS AND ACCESSORIES CS-NET Manager PSC-A64GTPC-ARFPE
47
Model No. Description Unit List Price
TW-22AN Utopia Inverter R410a Twin Branch Pipe £179
TW-102AN Utopia Inverter R410a Twin Branch Pipe £215
TG-53AN Utopia Inverter R410a Triple Branch Pipe £253
TG-103AN Utopia Inverter R410a Triple Branch Pipe £263
TRE-812N1 Utopia Inverter R410a Triple Header Branch £184
QE-812N1 Utopia Inverter R410a Quad Header Branch £199
E-102SN4 2-Pipe R410a Un-Insulated Multi Kit Line Branch £92
E-162SN4 2-Pipe R410a Un-Insulated Multi Kit Line Branch £123
E-242SN3 2-Pipe R410a Un-Insulated Multi Kit Line Branch £165
E-302SN3 2-Pipe R410a Un-Insulated Multi Kit Line Branch £194
E-52XN3 3-Pipe R410a Un-Insulated Multi Kit Line Branch £92
E-102XN3 3-Pipe R410a Un-Insulated Multi Kit Line Branch £127
E-162XN3 3-Pipe R410a Un-Insulated Multi Kit Line Branch £173
E-202XN3 3-Pipe R410a Un-Insulated Multi Kit Line Branch £200
E-242XN3 3-Pipe R410a Un-Insulated Multi Kit Line Branch £229
E-322XN3 3-Pipe R410a Un-Insulated Multi Kit Line Branch £271
MH-84AN1 2-Pipe R410a Un-Insulated Header Branch £202
MH-108AN 2-Pipe R410a Un-Insulated Header Branch £204
MH-108XN 3-Pipe R410a Un-Insulated Header Branch £282
DBS 12L Drain Boss Kit (RAS 2.0 ~ 2.5HVNP1E + RAS 3.0HVRNS3E) £14
DBS 26 Drain Boss Kit (All Outdoor Units except above) £14
DBS-TP10A Drain Boss Kit (Modular Set Free) £47
CONTROL SYSTEMS
SYSTEM FREE PIPE KITS & ACCESSORIES
48
Model No. Description Unit List Price
TRF-NP63S Renewal Kit RAS 2/2.5 IVX Comfort (External) £272
TRF-NP160S Renewal Kit RAS 3.0-6.0 IVX Comfort/Premium (External) £274
TRF-NP160U Renewal Kit RAS 4.0-6.0 IVX Premium (Internal) £255
TRF-NP280U Renewal Kit RAS 8.0 IVX Comfort/Premium (Internal) £331
TRF-NP335U1 Renewal Kit RAS 10.0-12.0 IVX Comfort/Premium (Internal) £331
CONTROL SYSTEMS
RENEWAL KITS (R22/R407C REPLACEMENT) UTOPIA IVX COMFORT & UTOPIA IVX PREMIUM
49
Model No. Nominal Heating Capacity kW Airflow (m3/hr) Dimensions
(HxWxD) mm Weight (kg) Description Unit List Price
LINEA M 1000 DX-H-K 3 9.0 1800 400x1000x460 52 3Hp 1000mm Air Curtain, Surface Mounted, 3.0m Mounting Height, Inc. DX Kit, 1Ø £4,506
LINEA M 1500 DX-H-K 4 14.0 2700 400x1500x460 83 4Hp 1500mm Air Curtain, Surface Mounted, 3.0m Mounting Height, Inc. DX Kit, 1Ø £5,194
LINEA M 2000 DX-H-K 6 18.0 3600 400x2000x460 113 6Hp 2000mm Air Curtain, Surface Mounted, 3.0m Mounting Height, Inc. DX Kit, 1Ø £5,795
LINEA M 2500 DX-H-K 8 25.0 4500 400x2500x460 145 8Hp 2500mm Air Curtain, Surface Mounted, 3.0m Mounting Height, Inc. DX Kit, 1Ø £6,721
Model No. Nominal Heating Capacity kW Airflow (m3/hr) Dimensions
(HxWxD) mm Weight (kg) Description Unit List Price
LINEA G 1000 DX-H-K 5 15.0 2700 400x1000x460 55 5Hp 1000mm Air Curtain, Surface Mounted, 4.0m Mounting Height, Inc. DX Kit, 1Ø £4,643
LINEA G 1500 DX-H-K 6 18.0 3600 400x1500x460 85 6Hp 1500mm Air Curtain, Surface Mounted, 4.0m Mounting Height,Inc. DX Kit, 1Ø £5,307
LINEA G 2000 DX-H-K 8 25.0 5400 400x2000x460 115 8Hp 2000mm Air Curtain, Surface Mounted, 4.0m Mounting Height, Inc. DX Kit, 1Ø £6,583
LINEA G 2500 DX-H-K 10 31.0 6300 400x2500x460 147 10Hp 2500mm Air Curtain, Surface Mounted, 4.0m Mounting Height, Inc. DX Kit, 1Ø £7,146
Model No. Nominal Heating Capacity kW Airflow (m3/hr) Dimensions
(HxWxD) mm Weight (kg) Description Unit List Price
AZRM 1000 DX-H-K 3 9 1800 260x1000x700 46 3Hp 1000mm Air Curtain, Recess/Void Mounted, 3.0m Mounting Height, Inc. DX Kit, 1Ø £5,394
AZRM 1500 DX-H-K 4 14 2700 260x1500x700 100 4Hp 1500mm Air Curtain, Recess/Void Mounted, 3.0m Mounting Height, Inc. DX Kit, 1Ø £5,782
AZRM 2000 DX-H-K 6 18 3600 260x2000x700 110 6Hp 2000mm Air Curtain, Recess/Void Mounted, 3.0m Mounting Height, Inc. DX Kit, 1Ø £6,383
AZRM 2500 DX-H-K 8 25 4500 260x2500x700 130 8Hp 2500mm Air Curtain, Recess/Void Mounted, 3.0m Mounting Height, Inc. DX Kit, 1Ø £7,309
Model No. Nominal Heating Capacity kW Airflow (m3/hr) Dimensions
(HxWxD) mm Weight (kg) Description Unit List Price
AZRG 1000 DX-H-K 5 15 2700 260x1000x700 48 5Hp 1000mm Air Curtain, Recess/Void Mounted, 4.0m Mounting Height, Inc. DX Kit, 1Ø £5,607
AZRG 1500 DX-H-K 6 18 3600 260x1500x700 102 6Hp 1500mm Air Curtain,Recess Void Mounted, 4.0m Mounting Height, Inc. DX Kit, 1Ø £5,995
AZRG 2000 DX-H-K 8 25 5400 260x2000x700 112 8Hp 2000mm Air Curtain, Recess/Void Mounted, 4.0m Mounting Height, Inc. DX Kit, 1Ø £7,084
AZRG 2500 DX-H-K 10 31 6300 260x2500x700 132 10Hp 2500mm Air Curtain, Recess/Void Mounted, 4.0m Mounting Height, Inc. DX Kit, 1Ø £7,760
CONTROL SYSTEMS
DOOR CURTAINSDOOR CURTAINS - SURFACE MOUNTED AIR CURTAIN, HEATING/COOLING, MOUNTING HEIGHT UP TO 3.0M
DOOR CURTAINS - SURFACE MOUNTED AIR CURTAIN, HEATING/COOLING, MOUNTING HEIGHT UP TO 4.0M
DOOR CURTAINS - SURFACE MOUNTED AIR CURTAIN, HEATING/COOLING, MOUNTING HEIGHT UP TO 4.0M
DOOR CURTAINS - RECESS/VOID MOUNTED AIR CURTAIN, HEATING/COOLING, MOUNTING HEIGHT UP TO 3.0M
50
DOMESTIC HEATINGTHE YUTAKI RANGE OF AIR SOURCE HEAT PUMPS PROVIDE EXCEPTIONAL YEAR-ROUND
PERFORMANCE FOR DOMESTIC HEATING AND HOT WATER
YUTAKI-M / P.51YUTAKI-S / P.51-52
YUTAKI-SCOMBI / P.53-54YUTAMPO WATER HEATER / P.54
YUTAKI-S80 / P.55ACCESSORIES / P.56
50
51
DOMESTIC HEATING
YUTAKI-MModel No.
Nominal Capacity Water 35/30°C
Ambient 7/6°C db/wb kWCOP
Water Connections
(Inch)
Minimum Water
Volume (L)
Water Flow Rate min/max
(l/s)
Sound Power Level (DB(A)
Power Supply (v/ph/Hz)
Suggested Fuse Rating With DHW Tank Heater (A)
Suggested Fuse Rating Without DHW
Tank Heater (A)
Expansion Vessel
Capacity (L)
Dimensions (HxWxD) mm
Weight (kg) Description System
List Price
RASM 3VNE 7.5 4.55 1 1/4" Female 28 0.6/2.1 61 230/1/50 32 20 6 800x1252x370 115 Monobloc Air to Water Heat Pump 1Ø £3,322
RASM 4VNE 11.0 5.0 1 1/4" Female 38 1.0/2.8 63 230/1/50 32 20 6 1380x1252x370 135 Monobloc Air to Water Heat Pump 1Ø £3,785
RASM 5VNE 14.0 4.7 1 1/4" Female 46 1.1/3.0 64 230/1/50 32 20 6 1380x1252x370 140 Monobloc Air to Water Heat Pump 1Ø £4,152
RASM 6VNE 16.0 4.57 1 1/4" Female 55 1.2/3.0 65 230/1/50 32 20 6 1380x1252x370 144 Monobloc Air to Water Heat Pump 1Ø £4,702
RASM 4NE 11.0 5.0 1 1/4" Female 38 1.0/2.8 63 400/3/50 50 32 6 1380x1252x370 135 Monobloc Air to Water Heat Pump 3Ø £3,933
RASM 5NE 14.0 4.7 1 1/4" Female 46 1.1/3.0 64 400/3/50 50 32 6 1380x1252x370 140 Monobloc Air to Water Heat Pump 3Ø £4,310
RASM 6NE 16.0 4.57 1 1/4" Female 55 1.2/3.0 65 400/3/50 50 32 6 1380x1252x370 144 Monobloc Air to Water Heat Pump 3Ø £4,862
DOMESTIC HEATING
YUTAKI-S SPLIT SYSTEMS - INDOOR UNITSModel No.
Nominal Capacity Water 35/30°C
Ambient 7/6°C db/wb kWCOP
Water Connections
(Inch)
Minimum Water
Volume (L)
Water Flow Rate min/max
(l/s)
Sound Power Level (DB(A)
Power Supply (v/ph/Hz)
Suggested Fuse Rating With DHW Tank Heater (A)
Suggested Fuse Rating Without DHW
Tank Heater (A)
Expansion Vessel
Capacity (L)
Dimensions (HxWxD) mm
Weight (kg) Description System
List Price
RMW 2.0NE 4.3 5.25 1" Female 28 0.5/1.9 37 230/1/50 20 6 1/4" - 5/8" 782x450x275 60 Split Air to Water Heat Pump - Indoor Unit £1,824
RWM 2.5NE 6.0 4.80 1" Female 28 0.6/2.0 37 230/1/50 20 6 3/8" - 5/8" 782x450x275 60 Split Air to Water Heat Pump - Indoor Unit £1,868
RWN 3.0NE 7.5 4.55 1" Female 28 0.6/2.1 37 230/1/50 20 6 3/8" - 5/8" 782x450x275 61 Split Air to Water Heat Pump - Indoor Unit £1,914
RWM 4.0NE 11.0 5.00 1 1/4" Female 38 1.0/2.9 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 960x520x360 71 Split Air to Water Heat
Pump - Indoor Unit £2,251
RWM 5.0NE 14.0 4.71 1 1/4" Female 46 1.1/3.0 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 960x520x360 71 Split Air to Water Heat
Pump - Indoor Unit £2,352
RWM 6.0NE 16.0 4.57 1 1/4" Female 55 1.2/3.0 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 960x520x360 71 Split Air to Water Heat
Pump - Indoor Unit £2,657
RWM 8.0NE 20.0 4.57 1 1/4" Female 76 2.0/4.5 47 230/1/50 + 400/3/50 20 6 3/8" - 1 1/8" 960x670x360 90 Split Air to Water Heat
Pump - Indoor Unit £3,065
RWM 10.0NE 24.0 4.30 1 1/4" Female 79 2.2/4.6 47 230/1/50 + 400/3/50 20 6 1/2" - 1 1/8" 960x670x360 93 Split Air to Water Heat
Pump - Indoor Unit £3,244
RASM-4-5-6(V)NE
RMW-NE
RASM-3VNE
52
DOMESTIC HEATING
YUTAKI-S SPLIT SYSTEMS OUTDOOR UNITS
DOMESTIC HEATING
HOT WATER CYLINDERS & BUFFER TANKS
Model No. Max Pipe Length (m) Chargeless Length/Additional Charge (kg/(m)/g/m) Power Supply Suggested Fuse Size
(Single/3 Phase)Pipe Sizes
(Liquid - Gas)Sound Power Level (DB(A)
Dimensions (HxWxD) mm Weight (kg) Description List Price -
Single PhaseList Price -
Three Phase
RAS 2WHVNP 50 15/30 230/1/50 20 1/4" - 1/2" 59 600x792x300 46 Split Air to Water Heat Pump - Indoor Unit £1,108 -
RAS 2.5WHVNP 50 15/30 230/1/50 20 1/4" - 1/2" 60 600x792x300 46 Split Air to Water Heat Pump - Indoor Unit £1,296 -
RAS 3WHVNP 50 15/40 230/1/50 20 3/8" - 5/8" 61 800x950x370 49 Split Air to Water Heat Pump - Indoor Unit £1,444 -
RAS 4WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 63 1380x950x370 116 Split Air to Water Heat Pump - Indoor Unit £2,207 £2,361
RAS 5WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 64 1380x950x370 116 Split Air to Water Heat Pump - Indoor Unit £2,535 £2,680
RAS 6WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 65 1380x950x370 116 Split Air to Water Heat Pump - Indoor Unit £2,866 £3,029
RAS 8WHNP 75 15/60 400/3/50 25 3/8" - 1 1/8" 71 1380x950x370 137 Split Air to Water Heat Pump - Indoor Unit - £4,115
RAS 10WHNP 75 15/60 400/3/50 25 1/2" - 1 1/8" 72 1380x950x370 138 Split Air to Water Heat Pump - Indoor Unit - £4,723
Model No. Description List Price
UKA-180UVC-01 180L Unvented Hot Water Cylinder £1,714
UKA-210UVC-01 210L Unvented Hot Water Cylinder £1,778
UKA-250UVS-01 250L Unvented Hot Water Cylinder with Solar Coil £2,127
UKA-300UVS-01 300L Unvented Hot Water Cylinder with Solar Coil £2,219
UKA-50UVB-01 50L Unvented Buffer Tank £402
UKA-95UVB-01 95L Unvented Buffer Tank £460
UKA-150UVB-01 150L Unvented Buffer Tank £526
UKA-210UVB-01 210L Unvented Buffer Tank £768
RAS 4-10WH(V)NP
UKA UV(C)(S)(B)
RAS 2-3WHVNP
53
DOMESTIC HEATING
YUTAKI-SCOMBI SPLIT SYSTEMS INDOOR UNITS
Model No.Nominal Capacity
Water 35/30°C Ambient 7/6°C db/wb kW
COPWater
Connections (Inch)
Minimum Water
Volume (L)
Water Flow Rate min/max
(l/s)
Sound Power Level (DB(A)
Power Supply (v/ph/Hz)
Suggested Fuse Rating With DHW Tank Heater (A)
Suggested Fuse Rating Without DHW
Tank Heater (A)
Expansion Vessel
Capacity (L)
Dimensions (HxWxD) mm
Weight (kg) Description System
List Price
RMD 2.0NWE-200S-K 4.3 5.25 1" Female 28 0.5/1.8 37 230/1/50 20 6 1/4" - 5/8" 1816x600x733 131Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£3,231
RWD2.0NWE-260S-K 4.3 5.25 1" Female 28 0.5/1.8 37 230/1/50 20 6 1/4" - 5/8" 1816x600x733 146Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£3,333
RWD 2.5NWE-200S-K 6.0 4.80 1" Female 28 0.6/1.9 37 230/1/50 20 6 3/8" - 5/8" 1816x600x733 131Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£3,342
RWD 2.5NWE-260S-K 6.0 4.80 1" Female 28 0.6/1.9 37 230/1/50 20 6 3/8" - 5/8" 1816x600x733 146Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£3,445
RWD 3.0NWE-200S-K 7.5 4.55 1" Female 28 0.6/1.9 37 230/1/50 20 6 3/8" - 5/8" 1816x600x733 132Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£3,456
RWD 3.0NWE-260S-K 7.5 4.55 1" Female 28 0.6/1.9 37 230/1/50 20 6 3/8" - 5/8" 1816x600x733 147Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£3,557
RWD 4.0NWE-200S-K 11.0 5.00 1 1/4" Female 38 1.0/2.7 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 1816x600x733 135
Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£4,125
RWD 4.0NWE-260S-K 11.0 5.00 1 1/4" Female 38 1.0/2.7 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 1816x600x733 150
Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£4,228
RWD 5.0NWE-200S-K 14.0 4.71 1 1/4" Female 46 1.1/2.8 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 1816x600x733 137
Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£4,143
RWD 5.0NWE-260S-K 14.0 4.71 1 1/4" Female 46 1.1/2.8 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 1816x600x733 152
Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£4,246
RWD 6.0NWE-200S-K 16.0 4.57 1 1/4" Female 55 1.2/2.8 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 1816x600x733 137
Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£4,289
RWD 6.0NWE-260S-K 16.0 4.57 1 1/4" Female 55 1.2/2.8 39 230/1/50 + 400/3/50 20 6 3/8" - 5/8" 1816x600x733 152
Split Air to Water Heat Pump - Indoor Unit &
DHW Cylinder£4,390
RWD 2.0~6.0NWE (200/260)S-K
54
DOMESTIC HEATING
YUTAKI-SCOMBI SPLIT SYSTEMS OUTDOOR UNITS
Model No. Max Pipe Length (m) Chargeless Length/Additional Charge (kg/(m)/g/m) Power Supply Suggested Fuse Size
(Single/3 Phase)Pipe Sizes
(Liquid - Gas)Sound Power Level (DB(A)
Dimensions (HxWxD) mm Weight (kg) Description List Price -
Single PhaseList Price -
Three Phase
RAS 2WHVNP 50 15/30 230/1/50 20 1/4" - 1/2" 59 600x792x300 46 Split Air to Water Heat Pump - Outdoor Unit £1,108 -
RAS 2.5WHVNP 50 15/30 230/1/50 20 1/4" - 1/2" 60 600x792x300 46 Split Air to Water Heat Pump - Outdoor Unit £1,296 -
RAS 3WHVNP 50 15/40 230/1/50 20 3/8" - 5/8" 61 800x950x370 49 Split Air to Water Heat Pump - Outdoor Unit £1,444 -
RAS 4WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 63 1380x950x370 116 Split Air to Water Heat Pump - Outdoor Unit £2,207 £2,361
RAS 5WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 64 1380x950x370 116 Split Air to Water Heat Pump - Outdoor Unit £2,535 £2,680
RAS 6WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 65 1380x950x370 116 Split Air to Water Heat Pump - Outdoor Unit £2,866 £3,029
RAS 4-6WH(V)NPRAS 2-3WHVNP
DOMESTIC HEATING
YUTAMPO WATER HEATER - INTERNAL UNIT
DOMESTIC HEATING
YUTAMPO WATER HEATER - OUTDOOR UNIT
Model No. Net Water Volume (l) COP Stand-By
Power (w)Heat Up Time
(10-53°C)
Max Volume of Usable Water (Vmax)(40°C)
Hot Water Reference
Temperature
Tank Working Range
(Inc. Electric Heater
Dimensions Weight (Dry)
Pipe Sizes (Liquid - Gas)
Water Pipe Connection Size (Inlet & Outlet)
(Inch)
Electric Heater (kw)
Power Supply
(v/ph/hz)
Recommended Fuse Size (A) Description List Price
TAW-270NH2A 270.0 3.20 33 4h20min 355 47.5 40-55°C (65°C) 1570x600x730 63 1/4" - 1/2" G 3/4" Male 2.0 230/1/50 20.0 Yutampo Indoor Unit £1,609
Model No. Max Pipe Length (m) Chargeless Length/Additional Charge (kg/(m)/g/m) Power Supply Suggested Fuse Size
(Single/3 Phase)Pipe Sizes
(Liquid - Gas)Sound Power Level (DB(A)
Dimensions (HxWxD) mm Weight (kg) Description List Price
RAW-25NH2A 20 -15 - +37°C 230/1/50 32/16 1/4" - 1/2" 46 570x750x280 38 Yutampo Outdoor Unit £774
TAW-NH2A
RAW-NH2A
55
DOMESTIC HEATING
YUTAKI-S80 SPLIT SYSTEMS - INDOOR UNITS
DOMESTIC HEATING
YUTAKI-S80 SPLIT SYSTEMS - OUTDOOR UNITS
Model No.Nominal Capacity
Water 35/30°C Ambient 7/6°C db/wb kW
COPWater
Connections (Inch)
Minimum Water
Volume (L)
Water Flow Rate min/max
(l/s)
Sound Power Level (DB(A)
Power Supply (v/ph/Hz)
Suggested Fuse Rating With DHW Tank Heater (A)
Suggested Fuse Rating Without DHW
Tank Heater (A)
Expansion Vessel
Capacity (L)
Dimensions (HxWxD) mm
Weight (kg) Description
List Price - Single Phase
List Price - Three Phase
RWH 4.0(V)NFE 11.0 5.00 1 1/4" Female 40 1.0/2.8 57 230/1/50 + 400/3/50 32/16 12 3/8" - 5/8" 802x600x623 116
Split Air to Water Very High Temperature Heat
pump - Indoor Unit£4,296 £4,773
RWH 5.0(V)NFE 14.0 4.71 1 1/4" Female 50 1.1/3.2 57 230/1/50 + 400/3/50 32/16 12 3/8" - 5/8" 802x600x623 116
Split Air to Water Very High Temperature Heat
pump - Indoor Unit£4,641 £5,072
RWH 6.0(V)NFE 16.0 4.57 1 1/4" Female 50 1.2/3.2 58 230/1/50 + 400/3/50 32/16 12 3/8" - 5/8" 802x600x623 116
Split Air to Water Very High Temperature Heat
pump - Indoor Unit£5,047 £5,610
Model No. Max Pipe Length (m) Chargeless Length/Additional Charge (kg/(m)/g/m) Power Supply Suggested Fuse Size
(Single/3 Phase)Pipe Sizes
(Liquid - Gas)Sound Power Level (DB(A)
Dimensions (HxWxD) mm Weight (kg) Description List Price -
Single PhaseList Price -
Three Phase
RAS 4WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 63 1380x950x370 116 Split Air to Water Heat Pump - Outdoor Unit £2,207 £2,361
RAS 5WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 64 1380x950x370 116 Split Air to Water Heat Pump - Outdoor Unit £2,535 £2,680
RAS 6WH(V)NP 75 15/60 230/1/50(400/3/50) 32/16 3/8" - 5/8" 65 1380x950x370 116 Split Air to Water Heat Pump - Outdoor Unit £2,866 £3,029
DOMESTIC HEATING
HOT WATER CYLINDERS & BUFFER TANKSModel No. Description List Price
UKA-180UVC-01 180L Unvented Hot Water Cylinder £1,714
UKA-210UVC-01 210L Unvented Hot Water Cylinder £1,778
UKA-250UVS-01 250L Unvented Hot Water Cylinder with Solar Coil £2,127
UKA-300UVS-01 300L Unvented Hot Water Cylinder with Solar Coil £2,219
RWH 4.0~6.0(V)NFE
UKA-UV(C)(S)
RAS 4-6WH(V)NP
56
DOMESTIC HEATING
ACCESSORIESAccessories
Model No. Description List Price
PC-ARFHE Unit Main Controller £95
ATW-RTU-04 Wireless On/Off Thermostat £176
ATW-RTU-05 Wireless Intelligent Thermostat £208
ATW-RTU-06 Wireless Intelligent Thermostat for Second Circuit £127
ATW-CKS-01 Cooling Kit - Yutaki-S - 4.3kW - 7.6kW £49
ATW-CKS-02 Cooling Kit - Yutaki-S - 11kW - 16kW £49
ATW-CKS-03 Cooling Kit - Yutaki-S - 20 - 24kW £49
ATW-CKSC-01 Cooling Kit - Yutaki S-Combi £49
ATW-CKM-01 Cooling Kit - Yutaki M £49
ATW-2TK-03 2nd Zone Mixing Kit (Integrated for Yutaki-SCombi) £49
ATW-2TK-04 2nd Zone Mixing Kit (Wall Mounted) £838
ATW-YMM-01 Yutaki-M Remote Control Box (Slave) £269
ATW-MAK-01 Kit for 4-20mA Application £24
ATW-ITS-01 Indoor Wired Temperature Sensor £24
ATW-WCV-01 Water Check Valve £32
WEH-6E Both 1Ø & 3Ø 6kW Electric Heater - 2/4/6kW Stages) £599
ATW-HSK-01 Hydraulic Seperator £310
ATW-3WV-01 3 Way Valvve £130
ATW-AQT-01 Aquastat £120
ATW-WTS-02Y Water Temperature Sensor For Hot Water Tank (Included with HAPE Tank) £49
Accessories
Model No. Description List Price
DBS-26 Drain Boss £15
ATW-DPK-01 Drain Pan Kit for RWM £88
ATW-DPK-02 Drain Pan Kit for RWM £88
ATW-SPS-01 Drain Pan Kit for RWM £191
ATW-20S-02 Swimming Pool Sensor £169
ATW-AOS-02 2nd Outdoor Temperature Sensor £159
ATW-CKM-01 Cooling Kit - Yutaki M £181
ATW-DPK-02 Drain Pan Kit for RWM £218
ATW-SPS-01 Drain Pan Kit for RWM £296
ATW-20S-02 Swimming Pool Sensor £227
ATW-AOS-02 2nd Outdoor Temperature Sensor £92
ATW-TAG-02 TaHoma Gateway £156
ATW-MVM-01 Mixing Vbalve Motor £117
ATW-KNX-02 KNX to H-Link Interface £83
ATW-MBS-02 Modbus Gatebridge £124
UKA-IVS-01 Isolation Valve/Strainer Kit £5,072
UKA-FLH-01 1 x Pair Pre-Insulated Flexible Hose Kit £5,072
UKA-AVF3-01 1 x Pack of 3 Anti-Vibration Feet (Yutaki-M) £5,072
AKA-AVF2-01 1 Pack of 2 Anti-Vibration Feet (Yutaki-S, Scombi, S80) £5,072
UKA-G3K-01 Unvented Cylinder G3 Kit £5,072
57
1. DEFINITIONS In these conditions;(1) “HITACHI” means: Hitachi Air Conditioning Europe SAS,
UK Branch (registration no. BR015653), Whitebrook Park, Lower Cookham Road, Maidenhead, Berkshire, SL6 8YA, United Kingdom.
(2) “Buyer” means: the person, firm or company specified overleaf, to whom HITACHI’s Quotation, SalesConfirmation or Invoice is addressed.
(3) “Goods” means: the goods to be sold by HITACHI to the Buyer under the Contract.
(4) “Contract” means: the contract of sale hereby formed between HITACHI and Buyer.
2. CONSTRUCTION OF CONTRACT(1) The terms of the Contract shall consist of the particulars
overleaf and these conditions. Any term overleaf which is at variance with these conditions shall prevail over these conditions, which shall be construed accordingly, except with regard to price in respect of which provisions of subclause 6 (2) shall prevail.
(2) No other terms (whether contained in any document issued by the Buyer or in any written or oral communication between the parties) shall apply to the Contract nor shall these conditions or the particulars overleaf be modified without HITACHI’s written agreement.
(3) These conditions and the particulars overleaf shall be a complete record of the agreement between the parties with regard to the sale of the Goods. These conditions apply to all sales of Goods by HITACHI to the Buyer and shall apply in place of and prevail over any terms or conditions contained or referred to in the Buyer’s order or in correspondence or elsewhere or implied by trade, custom, practice or course of dealing unless agreed to in writing pursuant to subclause 2 (2) above and any purported provisions to the contrary are hereby excluded or extinguished.
(4) The Buyer must ensure that any pre-contractual representation on which it wishes to rely has been specified in the particulars overleaf. In entering the Contract, the Buyer does not rely upon any such representation made by or on behalf of HITACHI which has not been so specified.
(5) The acceptance by HITACHI of any Buyer’s order, wholly or partly, does not imply any commitment by HITACHI to accept any other order (or any other part of an order) whenever placed.
3. QUOTATIONS AND ORDERS(1) Unless accepted before lapse or withdrawal, or renewed
in writing by HITACHI, quotations shall lapse automatically after 30 days, but may be withdrawn earlier by HITACHI.
(2) Quotations are for information only and are not firm offers. There shall be no binding contract until HITACHI has accepted the buyer’s order by dispatching HITACHI’s official Sales Confirmation.
4. DELIVERY(1) The scope of supply by HITACHI under the Contract shall
be strictly limited to those specified overleaf, and no other goods or services are included.
(2) HITACHI will use all reasonable endeavours to deliver the Goods on or before the delivery date specified overleaf, however, HITACHI does not undertake, guarantee or warrant that delivery will be made on the delivery date specified.
(3) Any such delivery date specified shall be extended by any period or periods during which the manufacture or delivery of the Goods or other work by HITACHI in connection with this Contract is prevented, hindered, delayed or rendered uneconomic by reason of a Force Majeure Event (as defined in clause 19 below).
(4) The Buyer acknowledges that, in the case of semiconductor products, optoelectronic products and other electronic components, due to the advanced technology in the Goods and the specialist nature of the manufacturing process, manufacture of the Goods by HITACHI’s normal means may result in a loss of yield. In the event of such a loss of yield HITACHI shall notify the Buyer and shall use its best endeavours to supply the Goods in accordance with this Contract. If due to a Force Majeure Event or due to loss of yield HITACHI has insufficient stocks to meet all its commitments HITACHI may apportion stock between its customers at its sole discretion.
(5) If any delivery time specified overleaf is so extended by more that 90 days then the Buyer shall be entitled to give written notice to HITACHI requiring the Goods to be delivered within 30 days of the date of such notice, failing which the Buyer shall have the right to give further written notice determining the Contract forthwith.
(6) HITACHI shall be entitled to deliver the Goods in one or more installments. Where delivery is effected by installment each installment shall be treated as a separate contract. Delay in delivery or other default of any installment shall not relieve the Buyer of its obligations to accept and pay for the remaining deliveries.
(7) In the case of the Buyer residing in the United Kingdom, unless otherwise stated, HITACHI will at its own expense deliver to the Buyer’s premises. In the case of exports, unless otherwise stated, delivery will be FOB (Incoterms 2000) at a U.K. port designated by HITACHI.
(8) The delivery by HITACHI of a greater or lesser quantity of the Goods than the quantity provided for in the Contract, the delivery of other goods not provided for in the Contract, or the delivery of the Goods only some of which are defective, shall not entitle the Buyer to reject all of the Goods delivered. In order that HITACHI can comply with its carrier’s conditions any claim in respect of error in quantity or type of Goods or in respect of damage to the Goods in transit must be made in writing to HITACHI and the carrier notified in both cases within three days of receipt of the Goods. Failure to make such claim shall constitute unqualified acceptance of the Goods and waiver by the Buyer of all claims relating to error in quantity or type of goods delivered or relating to the condition of Goods delivered. Similarly, if any Goods invoiced by HITACHI are not delivered, in order that HITACHI can claim against its carriers where appropriate the Buyer must notify HITACHI within 10 days of the date of invoice, failing which the Buyer will be liable to pay for the Goods in full. Where liability for error in quantity, or
type of Goods or in respect of damage to the Goods in transit is accepted by HITACHI, HITACHI’s only obligation shall be, at its option, to make good any shortage or non-delivery and/or as appropriate to replace or repair any Goods found to be damaged or defective and/or to refund the cost of such Goods to the Buyer.
(9) If the Buyer refuses or fails to take delivery of Goods tendered in accordance with this Contract HITACHI shall be entitled to terminate this Contract with immediate effect, to dispose of the Goods as HITACHI may determine, and to recover from the Buyer any loss and expenses incurred as a result of such refusal or failure.
(10) Section 32 (2) of the Sale of Goods Act 1979 shall not apply. HITACHI shall not be required to give the Buyer the notice specified in Section 32 (3) of the Act.
(11) Unless expressly agreed in writing by HITACHI, all Goods shall be packed in accordance with HITACHI’s standard practice. The Buyer shall meet the costs of any special packaging requested by the Buyer or any packaging rendered necessary by delivery by any means other than HITACHI’s normal means of delivery.
5. RISK AND TITLE(1) Notwithstanding delivery, property in the Goods supplied
shall remain with HITACHI until those Goods and any other goods the subject of any other contract with HITACHI have been paid for in full (together with any accrued interest) and until property passes in accordance with this term:-
(a) Risk in the Goods shall pass on delivery and the Buyer shall store the Goods separately or in such a way as will show clearly that they are HITACHI’s property and the Buyer will ensure that they are kept in good condition and insured against loss or damage for HITACHI’s benefit. Until property in the Goods passes to the Buyer, the Buyer shall hold the proceeds of any claim on the insurance policy on trust for HITACHI and shall immediately account to HITACHI with the proceeds.
(b) The Buyer shall hold the Goods in a fiduciary capacity and as bailee for HITACHI who may without prejudice to any other of its rights repossess the Goods to which it has retained title as aforesaid and thereafter re-sell the same and for this purpose the Buyer hereby grants an irrevocable right and licence to HITACHI’s servants and agents to enter upon all or any of its premises with or without vehicles during normal business hours for the purpose of inspecting and/or repossessing Goods to which it has retained title. This right shall continue to subsist notwithstanding the termination of this Contract for any reason and is without prejudice to any accrued rights of HITACHI hereunder or otherwise.
(c) The Buyer may dispose of the Goods in the ordinary course of its business as principal and may pass title to a third party but the proceeds of sale arising therefrom shall be kept in a separate account on trust for HITACHI until such time as full payment for the Goods supplied has been made.
(d) HITACHI may at any time detach or separate any of its Goods which may have been incorporated in or attached to goods belonging to the Buyer or any third party.
(2) HITACHI reserve the right, exercisable at its option by notice in writing to the Buyer, to waive the provisions of
subclause 5(1) above at any time before payment has been made for the Goods supplied by the Buyer and to declare that property in the Goods shall have passed to the Buyer.
(3) Notwithstanding that property in the Goods shall not have passed to the Buyer, HITACHI, without prejudice to any other of its rights, may sue for the price of the Goods supplied in the event that payment is not made on the due date.
(4) Any return of Goods wholly or partly by the Buyer to HITACHI, except in the case of defective Goods pursuant to Clause 8, shall be subject to HITACHI’s prior written consent and Buyer’s payment to HITACHI of interest charges for the period from the date of HITACHI’s shipment of such Goods to the Buyer to the date of HITACHI’s receipt of such Goods. Freight, insurance and any other expenses incurred in connection with such return shall be borne by the Buyer.
6. PRICES(1) Unless otherwise stated overleaf, prices of the Goods
shall be exclusive of VAT, export duty and foreign import duty and any other import or other taxes, which shall where applicable be the subject of additional charges.
(2) Prices stated in any quotation or in HITACHI’s Sales Confirmation are provisional only and subject to adjustment to take account of increases in HITACHI’s costs and overheads, including, without limitation, costs of carriage and labour costs. The Contract price shall be HITACHI’s price ruling at the date of dispatch. All quotations/sales confirmations and invoices are issued subject to the unconditional reservation of HITACHI’s right to adjust prices in respect of the following:-
(a) Changes in the prevailing exchange rate between the currency in which the price is to be paid and the Japanese Yen.
(b) Changes in the current EU import duty.
7. PAYMENT(1) If HITACHI has granted the Buyer credit facilities, the
payment of the price must be made in full within 30 days of the date of invoice, unless otherwise specified overleaf or agreed to by HITACHI. Any extension of credit allowed for the Buyer may be changed or withdrawn at any time. Where no credit has been granted, payment must be made in full in cash prior to delivery. Payment shall be made in full direct to HITACHI in the currency invoiced. The Buyer shall not be entitled to exercise any right of set-off, counterclaim, abatement or analogous deduction against payment due to HITACHI. Time of payment is of the essence of a Contract. HITACHI reserves the right to suspend the provision of Goods to the Buyer where any amounts are overdue under any Contract with the Buyer until all such amounts have been paid.
(2) HITACHI shall be entitled to charge daily interest on any overdue sum at the rate of 3 per cent per annum above the current base lending rate of Barclays Bank PLC from due date until the date of actual payment in full (including any accrued interest) (after, as well as before, judgement).
(3) If, in the opinion of HITACHI, the creditworthiness of the Buyer shall have deteriorated prior to the delivery, HITACHI may require full or partial payment of the price
prior to delivery or the provision of security for payment in full (including any accrued interest) by the Buyer in a form acceptable to HITACHI notwithstanding any credit terms that may have been agreed between HITACHI and the Buyer.
(4) Notwithstanding any purported contrary appropriation by the Buyer, all payments made by the Buyer to HITACHI shall be appropriated first to Goods which have been resold by the Buyer and then to Goods which remain in the possession or under the control of the Buyer.
(5) HITACHI is entitled to offset any amount owing to it from the Buyer against any amount owed to the Buyer by HITACHI.
8. DEFECTIVE GOODS(1) If the Goods are defective on delivery, and the defects
arise from faulty materials or workmanship and are not caused by fair wear and tear, abnormal or unsuitable conditions of storage, transportation or use, or the combination of the Goods with any goods not supplied by HITACHI or any act, neglect or default of the Buyer or any third party and HITACHI is given written notice of the defects promptly upon discovery by the Buyer and at any rate within six months (or such other period of time as may specifically be agreed to by HITACHI for certain types of Goods) after delivery then, unless otherwise specified overleaf, HITACHI’s sole obligation shall be (at its option) to repair or replace the defective item or allow the Buyer the price thereof and to pay or reimburse the reasonable carriage charges for the return of defective Goods to HITACHI and for delivery of the replaced or repaired item.
(2) Unless otherwise agreed between HITACHI and the Buyer, if any of the Goods are not HITACHI made, the provisions of subclause 8(1) above shall apply only to the extent covered by any warranty made by the supplier of such Goods to HITACHI.
(3) The Buyer shall retain the Goods at its premises until instructed by HITACHI to return them. Goods alleged to be defective shall be subject to inspection and testing by HITACHI at its own or (if HITACHI so chooses) at the Buyer’s premises and the Buyer shall allow HITACHI adequate facilities at the Buyer’s premises to investigate the complaint.
(4) Subject to subclause 8(1) above, HITACHI gives no representation or warranty and there is not incorporated in the Contract any condition whether express or implied, statutory or otherwise, as to the Goods other than the statutory warranty of title, and any such representations, conditions or warranties are hereby expressly excluded and HITACHI shall be under no liability to the Buyer for any loss, damage or injury (including special, direct, indirect or consequential loss and loss of profit) resulting from defective materials, faulty workmanship or otherwise howsoever arising and whether or not caused by the negligence of HITACHI, its employees or agents SAVE THAT HITACHI shall accept liability for death or personal injury caused by the negligence of HITACHI.
HITACHI’S
CONDITIONS OF SALE
58
9. INSOLVENCY AND DEFAULT If the Buyer fails to pay HITACHI in accordance with these
conditions or breaches any other of these conditions or any other contract with HITACHI or enters into a deed of arrangement or commits an act of bankruptcy or compounds with his creditors or if a receiving order is made against him or if (being a company) an order is made or a resolution is passed for the winding-up of the Buyer (otherwise than for the purposes of amalgamation or reconstruction previously approved in writing by HITACHI) or if a receiver is appointed over any of the Buyer’s assets or undertakings or if circumstances arise which entitle the Court or a creditor to appoint a receiver or manager or which entitle the Court to make a winding-up order or if the Buyer takes or suffers any similar or analogous action in consequence of debt HITACHI may, without prejudice to its other rights, postpone delivery or manufacture (both in respect of the Contract in question and any other contracts HITACHI might have with the Buyer) until such payment has been made or other breach rectified and/or (at its option) to terminate the Contract (and/or any other such contracts) and to recover payment for all deliveries already made and for the cost of materials and labour already expended for the purpose of future deliveries (less any allowance of the value thereof as utilised by HITACHI for other purposes) and also to recover from the Buyer a sum equivalent to HITACHI’s loss of profit arising out of such termination. The exercise of HITACHI’s option to postpone delivery or manufacture shall not prevent the subsequent exercise of HITACHI’s option to terminate the Contract and/or any other such contracts.
10. THIRD PARTY RIGHTS(1) In this clause 10 “Third Party Rights” shall mean any rights
under letters patent, registered or unregistered designs, trademarks, copyright or any other intellectual property rights and rights in know-how whether or not capable of being protected by statute, which are owned or controlled by any third party.
(2) Where any of the Goods are produced to the Buyer’s specification or where the Buyer’s use of the Goods infringes any Third Party Rights notwithstanding that the Goods themselves do not constitute such an infringement, the Buyer shall indemnify HITACHI against all actions, claims, costs, damages or losses arising from any infringement of such rights in respect of the Goods so produced or the use to which the Buyer has put the Goods as the case may be.
(3) Any reference by HITACHI to patents, copyright, registered designs, trade marks and analogous forms of protection shall not constitute a warranty of the validity thereof.
(4) HITACHI does not warrant that the Goods do not infringe any Third Party Rights, and all warranties to that effect whether express or implied, statutory or otherwise are hereby excluded. If at any time it is alleged that the Goods infringe any Third Party Rights, or if in HITACHI’s reasonable opinion such an allegation is likely to be made, HITACHI may at its option and at its own expense:
(a) modify or replace the Goods without detracting from
the overall performance of the Goods, so as to avoid the infringement; or
(b) procure for the Buyer the right to continue to use the Goods; or
(c) repurchase the Goods at the price paid by the Buyer.(5) HITACHI shall have no liability to the Buyer in the event
of Goods infringing or being alleged to infringe any Third Party Rights. In the event that the Goods are or may be the subject of Third Party Rights, HITACHI shall be obliged to transfer to the Buyer only such right, title or interest as HITACHI may have.
(6) The Buyer shall notify HITACHI forthwith of any claim made or action brought or threatened alleging infringement of any Third Party Rights. HITACHI shall have control over and conduct any such proceedings in such manner as it shall determine. The Buyer shall provide all such reasonable assistance in connection therewith as HITACHI may request.
11. SPECIFICATIONS AND INFORMATION(1) Unless expressly agreed in writing by HITACHI, all drawings,
designs, specifications and particulars of dimensions and weights and other such information submitted by HITACHI are approximate only and HITACHI shall have no liability in respect of any deviation therefrom. HITACHI shall be entitled to amend the technical specifications of the Goods without notice.
(2) HITACHI accepts no responsibility for any errors, omissions or other defects in any drawings, designs or specifications prepared by, or on behalf of, the Buyer or the Buyer’s agents, sub-contractors or employees, and HITACHI shall be indemnified by the Buyer against any and all liabilities and expenses incurred by HITACHI arising therefrom.
(3) All drawings, designs, specifications and information submitted by HITACHI are confidential and shall not be disclosed to any third party without HITACHI’s written consent.
12. LIMITATION OF LIABILITY(1) HITACHI shall not be liable for any indirect or consequential
loss, loss of revenue, loss of goodwill, and/or loss of anticipated savings in each case howsoever caused.
(2) Without prejudice to subclause 12(1) HITACHI shall not be liable to the Buyer for any loss or damage whether for negligence, breach of contract, misrepresentation or otherwise, for a sum greater, in aggregate, than the amount actually paid by the Buyer to HITACHI under the Contract.
(3) The limitation of liability in subclauses 12(1) and 12(2) above shall not operate to exclude or restrict HITACHI’s liability for fraud or deceit or for death or personal injury caused by its negligence.
(4) For the avoidance of doubt HITACHI will have no liability to the Buyer for any delays in deliveries due to circumstances described in subclauses 4(3) and 4(4) of these conditions.
13. ASSIGNMENT Neither party shall without the prior written consent of
the other party (which shall not be unreasonably withheld) assign or sub-contract any of its rights or duties under the Contract and upon such consent being given shall furnish copies of any such assignments to the other party.
14. LICENSES AND CONSENTS(1) If any license or consent of any government or other
authority shall be required for the acquisition, carriage or use of the Goods by the Buyer, the Buyer shall obtain the same at its own expense and if necessary produce evidence of the same to HITACHI on demand. Failure to do so shall not entitle the Buyer to withhold or delay payment of the price. Any additional expenses or charges incurred by HITACHI resulting from such failure shall be for the Buyer’s account.
(2) If HITACHI needs to obtain an export license from the competent authorities of the U.K. or, in the case of a drop shipment, of another country, the Buyer shall furnish HITACHI with all information required by HITACHI for such purpose, including, but not limited to, the country of ultimate destination and the name and address of the consignee, and shall warrant that such information is true, accurate and sufficiently detailed. The Buyer further agrees to take all necessary procedures in connection therewith, including, but not limited to, application for and acquisition of international import certificate, import license and delivery verification, as applicable. The Buyer shall not directly or indirectly re-export the Goods, wholly or partly, or any relevant technology, services or technical data to those countries, the export of such Goods, technology, services or data to which is restricted under the laws of the government issuing the said relevant export license (except where such export license specifically approves). In the event that any of the Goods, or any materials, parts or components incorporated in them, or relevant technical data supplied by HITACHI are of United States origin, the Buyer agrees to comply with the U.S. Export Administration regulations.
(3) The Buyer shall not export, re-export or make available the Goods, wholly or partly or any relevant technical data to any destinations subject to United Nations, EC and/or national sanctions, or to any person or organisation subject to United Nations, EC and/or national sanctions, or for any purpose prohibited by such sanctions. The Buyer shall not resell the Goods, whether directly or indirectly, for export to a country in breach of any export controls, laws, rules or regulations of the country of origin of the Goods.
(4) The Buyer confirms that the Goods or any relevant technical data will not be used for purposes related to the proliferation of any weapons of mass destruction (chemical, biological or nuclear weapons and related missiles).
(5) The Buyer shall keep documentation for at least four (4) years from the date of HITACHI’s shipments as evidence that all Goods supplied to the Buyer have been received in the destination permitted under the laws of the government issuing the export licence, and the Buyer will produce such evidence upon HITACHI’s request.
(6) HITACHI’s obligations under any Contract shall be conditional upon all necessary licenses or consents being obtained from the relevant authorities.
(7) The Buyer shall separately confirm to HITACHI the strict observation hereof (Notice of Confirmation).
15. TRADE TERMS In any case where Goods are sold CIF or FOB or on the
basis of other international trade terms, the meaning of such terms contained in Incoterms 2000 as revised from time to time shall apply except where inconsistent with any of the provisions contained in these conditions.
16. WAIVER Failure by HITACHI to exercise or enforce any rights
hereunder shall not be deemed to be a waiver of any such right nor operate so as to bar the exercise or enforcement thereof at any time or times thereafter.
17. NOTICES Any notice hereunder shall be deemed to have been duly
given if sent by pre-paid first class post, telex, or telefax to the party concerned as its last known address. Notices sent by first class post shall be deemed to have been given seven days after dispatch and notices sent by telex or telefax shall be deemed to have been given on the date of dispatch.
18. CANCELLATION The contract may be cancelled or rescheduled by the
Buyer only with HITACHI’s written consent. In the event of such cancellation the Buyer shall pay to HITACHI a cancellation charge, equal to HITACHI’s cost incurred up to the date of cancellation plus HITACHI’s loss of profit. The amount of such charge shall be notified to the Buyer upon HITACHI’s written acknowledgement of cancellation and shall be paid within 30 days of such notification.
19. FORCE MAJEURE (1) If HITACHI is prevented, hindered or delayed from or in
supplying the Goods in accordance with these conditions by a Force Majeure Event HITACHI may, at its option:
(a) suspend deliveries while the Force Majeure Event continues;
(b) if HITACHI has insufficient stocks to meet its commitments, apportion available stocks between its customers as it decides; or
(c) terminate any contract so affected with immediate effect by written notice to the Buyer; and HITACHI shall not be liable for any loss or damage suffered by the Buyer as a result.
(2) In this clause “Force Majeure Event” means an event beyond the reasonable control of HITACHI including, without limitation, strike, lock-out, labour dispute or shortage of labour, act of God, war, riot, civil commotion, malicious damage, compliance with a law or governmental order, rule, regulation or direction, accident, breakdown of plant or machinery, fire, flood, storm, earthquake, shortage of utilities, materials or other circumstances
affecting the supply of materials from HITACHI’s normal source of supply for materials for the Goods.
20. LAW AND JURISDICTION The Buyer shall be responsible for all obligations, financial
or otherwise, imposed in respect of the Goods, on either of the parties, under any environmental legislation applicable to the parties, including but not limited to Directive 2002/96/EC on waste electrical and electronic equipment and any legislation enacted pursuant to it.
21. LAW AND JURISDICTION The law of the Contract shall be English law and the parties
hereby submit to the jurisdiction of the English Courts save that HITACHI shall be entitled to bring proceedings against the Buyer in the courts of any jurisdiction where the Buyer resides or carries on business.
22. INTELLECTUAL PROPERTY RIGHTS The Buyer agrees that it shall not obtain any right, title
or interest in or to any intellectual property (including, without limitation, patents, trademarks, registered or unregistered designs, copyrights and rights in designs or inventions) in the Goods and that it shall not do or permit anything to be done in its use of such intellectual property in the Goods which would or could jeopardise their validity.
23. GENERAL(1) Headings herein are for easy reference purpose only, and
shall not be construed as defining the scope or meaning of any provisions.
(2) The invalidity, illegality or unenforceability of the whole or part of a condition does not affect or impair the continuation in force of the remainder of these conditions.
(3) A person who is not a party to this contract has no right under the Contracts (Rights of Third Parties) Act 1999 to enforce any of its terms but this does not affect any right or remedy of a third party which exists or is available apart from that Act.
(4) A reference to a statutory provision includes a reference to the statutory provision as modified or re-enacted or both from time to time and any subordinate legislation made under the statutory provision.
February 2017
HITACHI’S
CONDITIONS OF SALE
BUILDING OUR REPUTATION OF QUALITY ENGINEERING
FOR OVER 100 YEARS
HITACHI AIR CONDITIONING EUROPE SAS. (UK) Whitebrook Park, Lower Cookham Road, Maidenhead Berkshire SL6 8YA, United Kingdom
tel: 01628 585 394 email: [email protected] www. hitachiaircon.com
Specifications in the catalogue are subject to change without notice in order that HITACHI may bring the latest innovations to their customers, omitting typing errors.
HACE UK/IRL PL_001_17
HITACHI AIR CONDITIONING EUROPE SAS. (IRELAND) Unit 9, Bluebell Business Park, Old Naas Road Dublin 12, Ireland
tel: 00 353 1 216 4406 / fax: 00 353 1 216 4407 email: [email protected] www. hitachiaircon.com