Transcript
Page 1: Length x Width 1200 mm x 600 mm fileTemperature I SC α [%/K] +0.02 Temperature V OC β [%/K] -0.24 Temperature P MPP γ [%/K] -0.25 under STC. IMPP, VMPP, ISC, VOC are within ±10%

Temperature ISC α [%/K] +0.02

Temperature VOC β [%/K] -0.24

Temperature PMPP γ [%/K] -0.25

under STC. IMPP, VMPP, ISC, VOC are within ±10% of the indicated values under STC. Valid indoor measurement of STC performance is obtained by pretreating the module before measurement. For more information PAS-11-05-0203-EN.

Properties for system design (IEC)

Maximum System Voltage VSYS [V] 1000

Maximum Reverse Current IR [A] 3.5

Wind / Snow Load p [Pa] 2400

Safety Class II

Fire Rating C

ELECTRICAL CHARACTERISTICSPOWER CLASS CX3pro/2 CX3pro 80/2 CX3pro 82/2 CX3pro 85/2 CX3pro 87/2 CX3pro 90/2Nominal Power [+10% / -5%] PMPP [W] 80.0 82.5 85.0 87.5 90.0Current at max. Power IMPP [A] 1.87 1.89 1.92 1.95 1.97Voltage at max. Power VMPP [V] 43.5 44.4 44.9 45.5 46.4Short Circuit Current ISC [A] 2.13 2.14 2.16 2.17 2.19Open Circuit Voltage VOC [V] 56.7 57.1 57.6 58.1 58.6

Performance at normal operating cell temperature (NOCT: 800 W/m², 45 ±2°C, AM 1.5 Spectrum)POWER CLASS CX3pro/2 CX3pro 80/2 CX3pro 82/2 CX3pro 85/2 CX3pro 87/2 CX3pro 90/2Nominal Power PMPP [W] 61.4 63.4 65.3 67.2 69.1Current at max. Power IMPP [A] 1.50 1.52 1.55 1.57 1.59Voltage at max. Power VMPP [V] 41.7 42.5 43.0 43.6 44.5Short Circuit Current ISC [A] 1.71 1.72 1.74 1.75 1.76Open Circuit Voltage VOC [V] 54.3 54.7 55.2 55.7 56.1Performance at low irradiance

-trum) on request.

Length x Width 1200 mm x 600 mm

Thickness 6.9 mm (21.0 including junction box)

Weight 12.1 kg

Front Cover 3.2 mm glass

Back Cover 3.2 mm glass

Cell Type Cadmium telluride [CdTe]

Frame none

Junction Box Protection Class IP65

By-Pass Diode none

Cable Type Solar cable 2.5mm²

Cable Length 650 mm (+Cable), 850 mm (-Cable)

Connector MC 4

40045463

Note: Installation instructions must be followed. See the instruction and operating manual or contact the technical service for further information on approved installation and use of the product.Specifi cations subject to technical changes. Printed on environment-friendly paper. © TS Solar GmbH EU/ENG; CX3 /2 Feb. 2018

OT Thalheim, Sonnenallee 1a06766 Bitterfeld-Wolfen, Germany

TEL +49 (0)3494 368 980-0FAX +49 (0)3494 368 980-111

EMAIL [email protected] www.calyxo.com

TS Solar GmbH