![Page 1: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/1.jpg)
1
Introduction to building Estimating in South Australia
![Page 2: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/2.jpg)
2
ArchitecturalFloor plan
![Page 3: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/3.jpg)
3
Architectural plan building details
![Page 4: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/4.jpg)
4
Architecturalelevations
![Page 5: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/5.jpg)
5
Truss Layout via Pryda software
![Page 6: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/6.jpg)
6
Truss Report via Pryda software
![Page 7: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/7.jpg)
7
Conventional manual layout with trusses
![Page 8: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/8.jpg)
8
Production Truss plan used for manufacture- Critical measurements shown
Council Truss plans- Loads and engineering shown
Truss “T4”
![Page 9: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/9.jpg)
9
Truss “T10”
![Page 10: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/10.jpg)
10
How the plans look on site
![Page 11: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/11.jpg)
11
![Page 12: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/12.jpg)
12
![Page 13: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/13.jpg)
13
Truss to conventional hip end
Truss T 4
![Page 14: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/14.jpg)
14
Truss to conventional hip end (close up)
Truss “T4”
![Page 15: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/15.jpg)
15
Truss to conventional hip end(Halfway point)
Truss “T10”
![Page 16: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/16.jpg)
16
Truss T10
Truss to conventional hip end(side view truss “T10”
![Page 17: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/17.jpg)
17
Steel Facia
Hip end & Steel Facia
![Page 18: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/18.jpg)
18
Valley boards
![Page 19: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/19.jpg)
19
Panel “N”
Pryda software wall layout
![Page 20: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/20.jpg)
20Wall frame panel “N” Engineering for the lintel, for the size
Pryda software Engineering-Based on wind speed and loading
![Page 21: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/21.jpg)
21
Wind speed is indicated on the architectural drawings
Residential categories are:28 Km/h (N1)33 Km/h (N2)41 Km/h (N3)
The wind speed determines both bracing and beam loading for the building
Strip bracing OS panel bracing
![Page 22: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/22.jpg)
22
OS Bracing
Lintel
![Page 23: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/23.jpg)
23
Timber take-off list
Computer Manual
![Page 24: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/24.jpg)
24
The Building process on site
![Page 25: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/25.jpg)
25
Strip bracing
Top plate bracing
Bottom plate
Truss tie down
![Page 26: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/26.jpg)
26
Finished valley , Facia and gutters
Underside of eaves, facia and gutter
Brick work Tied to frame
![Page 27: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/27.jpg)
27
Fully trussed roof
Non-load bearing internal wall
![Page 28: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/28.jpg)
28
Typical multi dwellingMulti storey site- Scaffolding
![Page 29: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/29.jpg)
29
Floor trusses
2 StoreyBracing &Tie downs
Plumbing to be taken into considerationwith floor trusses
![Page 30: Introduction to building Estimating in South Australia 1](https://reader038.vdocuments.site/reader038/viewer/2022102900/551690d1550346f0208b46a4/html5/thumbnails/30.jpg)
30
Party fire walls between buildings
Fire check13 & 16mm