Download - Hilti Earthquake Product Brochure 2462.9kB
Hilti engineering for
earthquake applications
Building a future safer from earthquakes.in compliance with NZS4219 (Seismic Performance of Engineering Systems in Buildings) and NZS3101 (Concrete Standards)
Hilti. Outperform. Outlast.
Hilti engineering for
earthquake applications
ACI 355.2 and New European seismic regulations provide guidance for the qualification and design of post-installed anchoring
Under seismic loading, the performance of a
connection in a structure is crucial either to
its stability or in order to avoid casualties and
major economic impacts, due to the collapse
of non-structural elements.
In the United States the anchor seismic
resistance shall be evaluated in accordance
with ACI 318 Appendix D. Created in
accordance with the ACI 355.2 regulated
testing procedures and acceptance criteria
ICC-ES AC193 and AC308, pre-qualification
reports provide sound data in a proper
design format.
With the release of the ETAG 001 Annex E
in the first half of 2013, the seismic pre-
qualification of anchors became regulated
in Europe. Anchors submitted to these new
test procedures will now also incorporate in
the ETA (European Technical Approval) all the
required technical data for seismic design.
Until the release of the EN 1992-4, planned
for 2015, EOTA TR045 (Technical Report) will
set the standard for the seismic design of
steel to concrete connections. Therefore, the
design framework for the seismic design of
anchors is already available through both the
U.S. and European regulations. The National
Standard NZS 3101 and 4219 are currently
related to ACI 318 Appendix D and they
stipulate only anchors that have passed ACI
355.2 can be used for seismic applications.
Seismic Applicationsfor building construction
BC
Concrete Fastenings Hilti solutions
HIT-HY 200
• Fast-curing bonded anchor• SAFEset with the innovative HIT-Z rod
(no-cleaning)• HIT-Z Seismic ETA C2 approved• HSL, HDA & RE in compliance
with ACI 355.2
HY 200 with HIT-Z Rod
HSL
HDA
HST stud anchor, HUS screw anchor • Designed to excel in cracked concrete• HST Seismic ETA C2 approved• HUS anchor in compliance
with ACI 355.2
Fire Rated Walls/Floors/Joints Hilti solutions
Firestop foam, sleeve & blocks
High flexibility to cover movement of penetrants
Minimum damage, smoke-tight and tested fire integrity
Firestop acrylic & silicone sealant• Compensate shear movement due to
inter-story drift• Very good adhesion to substrate
material
Post-installed Rebars Hilti solutions
HIT-HY 200, HIT-RE 500-SD• Slow and fast curing for long and short
embedments• Approved for seismic rebar
Hollow drill bit• SAFEset installation system for safe
rebar installation
Detection systems (PS)
• Avoid bar hits when drilling• Identify existing bars for splices and
strengthening
M&ESeismic Applicationsfor mechanical & electrical
Hilti engineering for
earthquake applications
Electrical/Telecom Hilti solutions
Cable & conduit fasteners
• Most time and cost-efficient US code compliant method, e.g. up to 1.5’’ conduits
Firestop foam, sleeve & blocks
• High flexibility to cover movement of penetrants
• Minimum damage, smoke-tight and tested fire integrity
Utilities Fixing Hilti solutions
Anchoring to concrete
• Chemical and mechanical anchoring solutions
• Approved as per the new European seismic regulation
• In compliance with ACI 355.2
Fastenings to steel• Time and cost-efficient
fastening method • US code compliant for light
non-structural fastenings to steel base materials
Piping/Ventilation Hilti solutions
HST stud anchor, HUS screw anchor
• HST Seismic ETA C2 approved • HUS anchor in compliance with
ACI 355.2 • Easy installation
Retrofit & Cast-in Firestop Collar
• High flexibility to cover movement of penetrants
• Tested fire integrity and smoke tightness
Hilti engineering for
earthquake applications
S&MSeismic Applicationsfor steel & metalStructural Steel Hilti solutions
HIT-HY 200 with HIT-Z rod • SAFEset with the innovative HIT-Z rod (no-cleaning)
• HIT-Z Seismic ETA C2 approved• HSL in compliance with ACI 355.2
HST stud anchor, HUS screw anchor • Designed to excel in cracked concrete• Seismic approved solutions
(HST: ETA C2, HUS: ETA C1)• HSL in compliance with ACI 355.2
Powder actuated fasteners• US code compliant for light
non-structural fastenings to steel base materials
Ventilated Façade/Curtain Wall Hilti solutions
Eurofox façade system• Aluminum sub-construction for light
ventilated façade• Seismic tested as per CSTB
HST stud anchor • Approved as per the new European seismic regulation (ETA C2)
• In compliance with ACI 355.2
Firestop joint spray
• Compensate shear movement due to inter-story drift
• High regular movement capability
Decking Hilti solutions
X-ENP, EDN, EDNK screws
• Productive and US code compliant• Contribute to ductile deck behaviour in
seismic events• Comprehensive tool portfolio, including
standup tools
IFSeismic Applicationsfor interior finishing
Hilti. Outperform. Outlast.Hilti (New Zealand) Limited | Unit 1/B 525 Great South Road, Penrose | P 0800 444 584 | F 0800 329 445 | www.hilti.com
Hilti engineering for
earthquake applications
Suspended Ceilings Hilti solutions
HST studs, HUS screws• For bracing• Seismic approved solutions
(HST: ETA C2, HUS: ETA C1)• In compliance with ACI 355.2
PM 4-M multi-line laser
• Alignment in the horizontal, vertical and inclined planes
• Quick, easy and accurate
Interior Finishing Solutions Hilti solutions
Track fastenings • Productive and US code compliant
fastening for non-load bearing partition wall framing
Drywall screws
• Collated screws in perfect match to magazine SMD 57
• Fast working progress
Firestop sleeve & acrylic sealant • Seismic tested penetrations and joint
systems• Minimum damage, smoke-tight and tested
fire integrity