ComponentsA NIOSH approved EVA
Powered Air Purifying Respirator System consists of four components:(1) Hood or Mask(2) Breathing Tube(3) Blower Assembly(4) Purifying Filter Cartridge
1
2
3
4
3
Key SpecificationsNIOSH approvals:
HE: 21C-0836, 21C-0844, 21C-0846OVAGHE: 23C-2510, 23C-2511, 23C-2512
AM/FM/MA/AG/HE: 23C-2886Battery Technology: Rechargeable Lithium PolymerBattery Run Time: 4-16 hoursAirflow (lo/hi): 200/240 lpm, 7.0/8.5 cfm hoods
129/144 lpm, 4.5/5.0 cfm masks Alarms: Low Battery
Low FlowWarranty: 1 Year (Blower, Battery,
Charger)
4
Applications• Pharmaceutical Manufacturing• Healthcare• Chemical Handling• Laboratory Science• Painting• Powder Coating• Grinding• Welding• General Industrial
5
Typical Filter Applications Application Typical EVA Filter(s)
Fertilizer Manufacturing PARPFC5 (ammonia)
Food Processing PAPRFC5 (ammonia)
Grinding PAPRFC4 (metal chips)
Healthcare PAPRFC3 (TB, SARs, Influenza)
Laboratory Science PAPRFC3 (dander & virus)PARPFC5 (ammonia & formaldehyde)
Pharmaceutical Manufacturing PAPRFC3 (powders – granulation/tableting)PAPRFC4 (vapors & gases)PAPRFC5 (formaldehyde for capsule hardening)
Painting PAPRFC4 (organic solvents)
Powder Coating PAPRFC3 (powder)
Welding PARFC3 (metal fumes)
Wood Processing PAPRFC5 (formaldehyde)
6
Protection• 1,000 APF • Scientifically Valid & Legally Defensible• Independent, 3rd Party Testing
(RDECOM)• Rigorous Data Analysis
– 5th Percentile– Geometric Mean– Divided by 25 Safety Factor
7
Form Factor• User Validated
– The style workers have asked for• Recessed HE Filter
– Keeps a low profile• Single Filter Design (HE or Chemical)
– Reduces weight and simplifies operation – other PAPRs require up to 3 filter cartridges
• Stylish, Small, Compact, Lightweight– Maximizes comfort and appearance
• On-board Battery– No cables to snag or become unplugged
• Wide, padded, ergonomic belt– Maximum lumbar support and comfort– Or all vinyl option
8
Dual Speed• User controlled
– Toggle to the setting desired• High Speed for maximum comfort and
air flow– 8.5 CFM (240 lpm) - Hoods– 4.75 CFM - Masks
• Low Speed for personal preference and lesser air flow– 7.0 CFM (200 lpm) – 4.25 CFM - Masks
9
Dual Alarms• Audible Low Battery Alarm
– Beeps with at least 20 minutes of battery run time remaining
• Audible Low Flow Alarm– Constant when flow falls below 170 Lpm
(hoods)• Confidence• Safety• Peace of Mind
10
Battery Fuel Gauge• The remaining capacity of a battery is often a
mystery once it has been removed from the charger• EVA solves this mystery with the push of a button• LEDs illuminate to display the remaining capacity in
25% increments
11
Active Flow Technology• Think cruise control for your PAPR• Car cruise control
– Constant Speed– Changing hill or gas tank conditions
• PAPR control– Constant flow– Changing Hood Types or Filter Cartridge Conditions
• Other PAPRs – indirect flow control via RPM or voltage
• EVA Active Flow Technology– Unique feedback control loop that measures the flow
directly with a mass flow sensor
12
Brushless Motor• Brushless motors are the most
durable motors available lasting 10,000 hrs vs. 2,000 for a typical brush style motor
• The EVA combination of brushless motor and dynamically balanced impeller make it one of the quietest operating PAPRs available all while providing significantly higher air flows
13
Decon FriendlyDecon Friendly Design prevents cross contamination in
production batches while saving money by reducing cleanup time.
• Chemically Resistant Housing– Withstands a wide range of common cleaning solutions
• Closed Cell Foam Belt– Wipes down quickly
• Sealed & Gasketed Housing– Eliminates potential “traps” that might harbor debris
• Shower Cap Accessory– Allows user to utilize a decon shower while wearing the PAPR in
operation
14
“genius” Chargers• First, there were chargers• Then, along came smart chargers• Now, you can have a “genius” charger• Ever wonder how many cycles your battery has
performed?• With EVA you can access this via your computer with our
line of genius chargers• Several outputs are available including: Remaining
Capacity, Serial Number, Date of Manufacture, # of Cycles, Remaining Voltage– Single Port Smart Chargers (EVASMC)– Single Port “genius” Chargers (EVASMC2)– Six Port Smart Chargers (EVAGC)
15
Hood Style Headtops• All Hoods
– No Fit Testing Required– No Shaving Required
• CC20 Hoods– Standard ratchet headband– 1,000 APF for double bib models
• 20LF Loose Fitting Facepieces– Soft, sewn-in headband– 25 APF
• RT Series Hoods– NIOSH approved without a headband– 1,000 APF
• GR50 Series Grinding Hood– Nomex construction– 1,000 APF
16
New Headtops• T-Series
–Threaded Quick Connections for Breathing Tubes
–Available for CC20, RT, GR50
17
Mask Style Headtops• FAMB2 Half Mask
– Silicone Comfort– Low Profile– 50 APF
• Spectrum Full Face Mask– Silicone Comfort– Optical Clarity– 1,000 APF
18
Filters & Cartridges• PAPRFC3
– HEPA Particulate Filtration• PAPRFC4
– Organic Vapor– Acid Gas (CL,CD,HC,HF, SD)– HEPA Particulate Filtration
• PAPRFC5– Ammonia– Formaldehyde– Methylamine– Acid Gas (CL,CD,HC,HF,SD)– HEPA Particulate Filtration
• Accessories– Shower Cap– Pre-Filter (for FC4 & FC5)
• Cartridge Changeout– Use MaxxLife Software
19
Features & Benefits Summary• 1,000 APF• Recessed HE Filter• Single Filter Design (HE or Chemical)• Stylish, Ergonomic, Lightweight, & Compact• On-board Battery• Dual Speeds (7.0/8.5 CFM hoods, 4.5/5.0 CFM masks )• Dual Alarms (Battery & Flow)• Battery Fuel Gauge• Auto Flow Technology powered by a true Mass Flow Sensor• 10,000 hr brushless motor• 6 port gang chargers• Genius Chargers• 1 year warranty• Approved with Tychem Hoods, GRH Nomex Grinding Hood,
FAMB2 half mask, and Spectrum Full Face Mask• Single OVAGHE cartridge approved
20
Conversion & Implementation Support
• Free 30-day trials • Total Cost of Ownership Calculator • Personal, Expert, On-site training• Training Materials
– Powerpoint– Video
• SOP Templates• Quick Reference Guides