@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
02/20/15
A000
COVER SHEET
GENERALA000 COVER SHEETA001 ABBREVIATIONS SYMBOLS & NOTESCIVILC101 SITE PLANSTRUCTURALS101 FRAMING PLANS AND DETAILSEXISTINGB101 EXISTING BASEMENT AND FIRST FLOOR PLANB102 SECOND FLOOR AND ROOF PLAN - EXISTING
B201 EXTERIOR ELEVATIONS - EXISTINGB202 EXTERIOR ELEVATIONS - EXISTINGARCHITECTURALA101 BASEMENT AND FIRST FLOOR PLANA102 SECOND FLOOR AND ROOF PLANA103 PLAN DETAILS AND SCHEDULES
A201 EXTERIOR ELEVATIONSA202 EXTERIOR ELEVATION - PROPOSED
A501 BUILDING & WALL SECTIONSMECHANICALM000 MECHANICAL NOTES AND ABBREVIATIONSM101 MECHANICAL BASEMENT PLANM102 MECHANICAL SECOND FLOOR PLANELECTRICALE000 ELECTRICAL NOTES AND ABBREVIATIONSE101 ELECTRICAL FIRST FLOOR PLANE102 ELECTRICAL SECOND FLOOR PLAN
E401 ELECTRICAL MOUNTING HEIGHT DETAILS
location map: drawing index:development summary:
Powell Office Building Addition153 S. Liberty Street Powell, Ohio 43065
owner:
architect:
Scherner, Sybert and Rhoad
Berardi + Partners, Inc.Columbus, Ohio
systems engineers:
structural engineer:
Jezerinac GeersDublin, Ohio
contractor:
TBDCity, State
153 SOUTH LIBERTY STREET POWELL, OHIO DELAWARE COUNTY
Issue Description Date
building area totalsEXISTING BASEMENT/FOUNDATION 1283 SFEXISTING 1ST FLOOR 1657 SFEXISTING 2ND FLOOR 1283 SF
4223 SF
NEW AREA BASEMENT/FOUNDATION 192 SFNEW AREA 1ST FLOOR 192 SFNEW AREA 2ND FLOOR 192 SF
576 SF4799 SF
Berardi + Partners, Inc.Columbus, Ohio
GENERAL DESCRIPTION
THIS PROJECT IS TO BE A TWO STORY ADDITION TO A TWO STORY OFFICE BUILDING.THE BUILDING FEATURES A BASEMENT, AND THE ADDITION WILL INCLUDE A NEW BASEMENT AREAAND ONE NEW OFFICE SPACE AT EACH FLOOR.ACCESSIBILITY WILL BE IN CONFORMANCE WITH ICC/ANSI 117.1 - 2009 AND THE CURRENT OHIO BUILDING CODE
THIS BUILDING SHALL COMPLY WITH THE FOLLOWING CODES (LATEST EDITIONS IF NOT SPECIFIED)O.B.C. 2011 OHIO BUILDING CODE 2011NATIONAL ELECTRIC CODE (N.E.C.)NATIONAL FIRE PROTECTIONS ASSOCIATION (N.F.P.A.)
SITE SUMMARY
PARCEL I.D. 3194310204000STREET ADDRESS:153 SOUTH LIBERTY STREETPOWELL, OHIO 43065DELAWARE COUNTY
BUILDING USE: COMMERCIAL ('B')CONSTRUCTION TYPE:
EXISTING: VB, COMBUSTIBLE - UNPROTECTEDPROPOSED: VB, COMBUSTIBLE - UNPROTECTED
BUILDING AREA:EXISTING: BASEMENT = 1,283 SF1ST FLOOR=1,657 SF2ND FLOOR=1,283SF
4,223 SF TOTAL1,657 SF GROUND COVERAGE
PROPOSED:BASEMENT = 1,475SF (192SF ADDITION)1ST FLOOR = 1,849SF(192SF ADDITION)2ND FLOOR=1,475 SF(192SF ADDITION)
=4,799 SF TOTAL (576 SF INCREASE)1,849 SF GROUND COVERAGE (192 SF INCREASE)
BUILDING OCCUPANCY:BASEMENT IS STORAGE AREA (UNINHABITED)'B' = 100SF/OCCUPANTEXISTING = 1657 + 1283 = 2,940SF/100 = 29 OCCUPANTSPROPOSED 1849 + 1475 = 3,324SF/100 = 33 OCCUPANTS
ALLOWABLE BUILDING HEIGHT AND AREA:PER OBC TABLE 503 TYPE VB LIMITED TO 2 STORIESAND 9,000SF (BUILDING WITHIN LIMITATIONS)
INTERIOR WALL AND CEILING FINISHES TO MEET THE REQUIREMENTSOF OBC 2011 TABLE 803.9VERTICAL EXITS AND PASSAGEWAYS: CLASS AACCESS CORRIDORS AND OTHER EXITWAYS: CLASS BROOMS AND ENCLOSED SPACES: CLASS C
INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS TOCOMPLY WITH OBC SECTION 804
SITE AREA: 3.015 ACRE (131333.4 SF)
BUILDING COVERAGE:EXISTING = 4223/131,333= .032 = 3%PROPOSED=4,799/131333= .037 = 4%
PARKING SUMMARY:EXISTING = 11 SPACES (2 ACCESSIBLE)PROPOSED = 11 SPACES (2 ACCESSIBLE)NO CHANGE IN PARKING
DEFERRED SUBMITTALS
WITH PRIOR APPROVAL OF THE BUILDING OFFICIAL HAVING JURISDICTION, PORTIONSOF THE DESIGN THAT QUALIFY FOR DEFERRED SUBMITTAL AND ARE NOT SUBMITTEDAT THE TIME OF APPLICATION ARE TO BE SPECIFIED WITHIN A SPECIFIED TIME PERIOD.ALL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THEARCHITECT OR ENGINEER OF RECORD FOR APPROVAL BEFORE BEING FORWARDEDTO THE BUILDING OFFICIAL HAVING JURISDICTION WITH A NOTATION INDICATING THATTHE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND HAVE BEEN FOUNDTO BE IN GENERAL COMPLIANCE WITH THE DESIGN OF THE PROJECT
THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN ANDSUBMITTAL DOCUMENTS HAVE BEEN APPROVED. THE FOLLOWING CONSTRUCTIONDOCUMENTS MAY BE SUBMITTED AS A DEFERRED SUBMITTAL:1. THE SUBMISSION OF CERTIFIED WOOD ROOF AND FLOOR JOIST TRUSS
DETAILS SHALL BE REQUIRED FOR REVIEW AND EVALUATION PER OBC 2011SECTION 2303.4
PERMIT SET - JUNE 2, 2015
Powell, Ohio
ABBREVIATIONSA.F.F. ABOVE FINISHED FLOORACOUS. ACOUSTICAL CEILING TILEADJ. ADJUSTABLEAHU. AIR HANDLING UNITALT. ALTERNATEALUM. ALUMINUMA.B. ANCHOR BOLTBRG. BEARINGBDRM. BEDROOMBLK. BLOCKBLKG. BLOCKINGB/C BACK OF CURBBD. BOARDBOT. BOTTOMBLDG. BUILDINGC.B. CATCH BASINCLG. CEILINGC CENTER LINEC.O. CLEAN OUTC.W. COLD WATERCOL. COLUMNCONC. CONCRETEC.M.U. CONCRETE MASONRY UNITCONT. CONTINUOUSC.J. CONTROL JOINTCOORD. COORDINATEC.M.P. CORRUGATED METAL PIPEC.F.M. CUBIC FEET PER MINUTEDET. DETAILDIA. DIAMETERDIV. DIVISIONDR. DOORDBL. DOUBLEDN. DOWND.S. DOWNSPOUTDWG. DRAWINGE.W. EACH WAYE.W.C ELECTRIC WATER COOLERELEV. ELEVATIONEQUIP. EQUIPMENTEXIST. EXISTINGF.E. FIRE EXTINGUISHERF.E.C. FIRE EXTINGUISHER CABINETFLUOR. FLUORESCENTFL. FLOORF.D. FLOOR DRAINFT. FOOTFTG. FOOTINGGA. GAUGEG.F.I. GROUND FAULT INTERRUPTERG.S.F. GROSS SQUARE FEETGYP. BD. GYPSUM WALL BOARDH.C. HANDICAPHT. HEIGHTH.P.S. HIGH PRESSURE SODIUMH.M. HOLLOW METALHORIZ. HORIZONTALINSUL. INSULATIONINT. INTERIORINV. INVERTJT. JOINTLAM. LAMINATELVL LAMINATED VENEER LUMBERLT. LIGHTL.F. LINEAL FEETL.L.V. LONG LEG VERTICALL.L.H. LONG LEG HORIZONTALM.H. MANHOLE MFR. MANUFACTURERM.O. MASONRY OPENINGMAX. MAXIMUMMECH. MECHANICALMTL. METALMIN. MINIMUMMTD. MOUNTEDN.S.F. NET SQUARE FEETN.I.C. NOT IN CONTRACTN.T.S. NOT TO SCALENO. NUMBERO.C. ON CENTEROPNG OPENINGOPP. OPPOSITEO.S.B. ORIENTED STRAND BOARDPR. PAIRP.S.F. PER SQUARE FOOTP.S.I. PER SQUARE INCHPL. PLATE OR PROPERTY LINEP. LAM. PLASTIC LAMINATEPLYWD. PLYWOODP.T. PRESERVATIVE TREATEDRAD. RADIUSREQ'D. REQUIREDREINF. REINFORCINGR&S ROD AND SHELFR.D. ROOF DRAINSCHED. SCHEDULESHT. SHEETSIM. SIMILARSPECS. SPECIFICATIONSSQ. SQUARES.F. SQUARE FEETS.S. STAINLESS STEELSTD. STANDARDSTL. STEELTHK. THICKT&G TONGUE & GROOVET/ TOP OFTYP. TYPICALU.N.O. UNLESS NOTED OTHERWISEV.B. VAPOR BARRIERVERT. VERTICALV.T. VINYL TILEW/ WITHW/O WITHOUT
L
SYMBOLS
1. ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THEEXISTING CONDITIONS AND PROJECT REQUIREMENTS AND SHALLNOTIFY THE ARCHITECT OF ANY ERRORS OR OMISSIONS THUSRECOGNIZED.
2. THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGSAND PROJECT MANUAL IN THEIR ENTIRETY AND THE INFORMATION INTHESE DOCUMENTS IS DEPENDENT UPON AND COMPLIMENTARY OFEACH OTHER SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS THEY DO SO AT THEIR OWN RISK AND EXPENSE.
3. ALSO SEE NOTES ON THIS SHEET.
GENERAL NOTES:
1. PRIOR TO SUBMITTING A BID, ALL SUBCONTRACTORS SHALL VISIT THEPROJECT SITE & BECOME FAMILIAR WITH EXISTING CONDITIONS, COMPARE &CONFIRM THE CONTRACT DOCUMENTS, ANY SUBSEQUENT REQUIREMENTS &ALL REGULATORY AGENCY REQUIREMENTS APPLICABLE FOR COMPLETIONOF THE PROPOSED WORK. IF VARIATIONS OR DISCREPANCIES ARE FOUND,SAME INFORMATION SHALL BE FURNISHED IMMEDIATELY & IN WRITTENFORMAT TO THE DEVELOPER & TO THE ARCHITECT/ENGINEER PRIOR TOPROCEEDING WITH THE WORK.
2. ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TOCOMMENCING WORK. SHOULD DIMENSIONAL DISCREPANCIES EXIST, OR IFNOTED DIMENSIONS DO NOT COORDINATE WITH SPACE REQUIREMENTS OFEQUIPMENT, ETC., SAME INFORMATION SHALL BE FURNISHED IMMEDIATELYAND IN WRITTEN FORMAT TO THE DEVELOPER AND TO THEARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
3. ALL CONSTRUCTION AND MATERIALS SHALL BE IN STRICT COMPLIANCEWITH ALL LOCAL AND STATE BUILDING CODES AND REGULATIONS, AS WELLAS ANY OTHER SPECIFIC OR IMPLIED APPLICABLE REGULATIONS, INCLUDINGHEALTH AND SAFETY REQUIREMENTS, AS MAY BE IMPLIED OR STATED WITHISSUANCE OF THE BUILDING PERMIT.
4. PRIOR TO COMMENCEMENT OF ANY WORK, ALL PERMITS SHALL BEAPPLIED FOR AND OBTAINED BY EACH SUBCONTRACTOR, AND ALLAPPLICABLE FEES SHALL BE PAID BY THE SUBCONTRACTOR.
5. THE SCALE OF ALL DRAWINGS IS SUBJECT TO CONFIRMATION. ALLQUESTIONS SUBJECT TO THE CONTRACT DOCUMENTS SHALL BE DIRECTEDTO THE ARCHITECT.
6. EACH STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLEAFTER THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE GENERALCONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURESAND SEQUENCE, AND TO INSURE THE SAFETY OF THE BUILDINGS AND THEIRCOMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OFWHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS, WHICH MIGHT BE NECESSARY. FOLLOWING THE COMPLETION OF THEPROJECT, REDISTRIBUTION OF SUCH MATERIAL SHALL BE THERESPONSIBILITY OF THE GENERAL CONTRACTOR.
7. IT IS SOLELY THE GENERAL CONTRACTOR'S RESPONSIBILITY TO FOLLOWALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASESOF CONSTRUCTION.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATINGMECHANICAL, PLUMBING AND ELECTRICAL SYSTEMS, AND FOR INSTALLINGALL NECESSARY BLOCKING, FRAMING OR GENERAL CONSTRUCTION TOFACILITATE INSTALLATION OF SAID MECHANICAL AND ELECTRICALSYSTEMS. MECHANICAL AND ELECTRICAL SUB- CONTRACTORS SHALLDETERMINE DURING THE BID PROCESS ANY ADDITIONAL COSTS RELATEDTO VARIATIONS IN THE MECHANICAL AND ELECTRICAL REQUIREMENTS ANDSHALL NOTIFY THE ARCHITECT ACCORDINGLY.
9. SPECIFICATIONS (THE PROJECT MANUAL) ARE A PART OF THE CONTRACTDOCUMENTS. INFORMATION CONTAINED IN THE SPECIFICATIONS MAY NOTNECESSARILY BE CONTAINED AS PART OF THE DRAWINGS. ALLCONTRACTORS AND SUBCONTRACTORS SHALL PROVIDE THAT THEIRPROJECT COSTS INCLUDE ALL MATERIALS, LABOR AND OTHERPROCESSES REQUIRED TO COMPLETE ALL CATEGORIES OF THE WORKINDICATED BY ALL OF THE CONTRACT DOCUMENTS, OR THAT WORK WHICHMAY OTHERWISE BE IMPLIED FOR THE TOTAL COMPLETION OF THEPROJECT. FOR OTHER REQUIREMENTS, REFER TO THE GENERALCONDITIONS OF THE CONTRACT FOR CONSTRUCTION, PARTICULARLYPARAGRAPH 1.1.1.
10. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANSCONFLICT WITH GENERAL NOTES, THE SPECIFICATIONS, OR WITH EACHOTHER, THE STRICTEST PROVISION FOR BIDDING PURPOSES SHALLGOVERN. FOLLOWING BID AWARD THE CONTRACTOR SHALL CONSULTWITH THE ARCHITECT FOR CLARIFICATION REGARDING THE NOTEDDISCREPANCY.
11. DRAWINGS SHALL NOT BE SCALED. ALL QUESTIONS WITH RESPECT TO THECONTRACT DOCUMENTS SHALL BE DIRECTED TO THE ARCHITECT FORMAKING INTERPRETATIONS ON ALL ITEMS OF DISCREPANCY OR OF ANAMBIGUOUS NATURE.
12. DIMENSIONS AT EXTERIOR WALLS ARE OUT TO OUT OF STUD. DIMENSIONSAT INTERIOR WALLS ARE TO FACE OF STUD.
13. ALL BEARING WALLS ARE AS INDICATED ON THE STRUCTURAL DRAWINGS.14. INSULATION: ON WALLS BETWEEN UNITS PROVIDE INSULATION BEHIND ALL
OUTLETS, PLUMBING STACKS AND WATER SUPPLY LINES.15. INSULATION THAT IS EXPOSED TO ROOMS, ATTICS OR CRAWL SPACES
SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKEDEVELOPED RATING OF 450 OR LESS.
16. INSULATION IN CONCEALED SPACES SHALL HAVE A FLAME SPREAD RATINGOF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 450 OR LESS.INSULATION FACING IS NOT REQUIRED TO HAVE A FLAME SPREAD RATING IFIT IS IN A CONCEALED SPACE AND THE FACING IS IN CONTACT WITH A WALLOR CEILING.
17. ALL FOAM PLASTIC INSULATION SHALL BE PROTECTED IN ACCORDANCEWITH THE BUILDING CODE.
18. BLOCKING: PROVIDE SOLID BLOCKING BEHIND ALL HANDRAILS, GRABBARS, WALL CABINETS, WALL HUNG SINKS, SHELVES, RODS ANDACCESSORIES.
19. PROVIDE WOOD BLOCKING IN ALL STANDARD AND HANDICAP DESIGNATEDBATHROOMS OF ONE STORY LIVING UNITS FOR INSTALLATION OF FUTUREAND CURRENT GRAB BARS.
A1
10
0
B
AA1
A
W1
1
12
AA1
AA1
A
OFFICE
100
LARGE SCALE PLAN LOCATERELEVATION DETAIL LOCATER
DETAIL LOCATER
WALL SECTION LOCATER
BUILDING SECTION LOCATER PARTITION TYPE NUMBER
COLUMN LINE NUMBER
WINDOW TYPE INDICATOR
DOOR NUMBERSEE DOOR SCHEDULES FORADDITIONAL DOOR INFORMATION
DOOR
DOOR NUMBER
KEYNOTE INDICATOR
INTERIOR ELEVATION LOCATER
INDEX LETTER
SHEET NUMBERREVISION NUMBERINDICATES REVISIONS IN CLOUDEDAREAS. REVISION NUMBERCORRESPONDS TO REVISIONDATE ON TITLE STRIP.
SECTIONIDENTIFICATIONSHEET WITHSECTION
AA1
INDEX LETTERSHEET NUMBEROF SECTION
LOCATER
INDEX LETTERSHEET NUMBEROF DETAIL
ROOM NUMBERSEE ROOM FINISH SCHEDULESFOR ADDITIONAL ROOM ANDFINISH INFORMATION
ROOM NAME
ROOM NUMBER
LOCATER
SHEET NUMBERINDEX LETTER
06.46B
GENERAL DEMOLITION NOTES:
1. THESE DRAWINGS AS PART OF THE DOCUMENTS SHALL BE VIEWED ANDCONSIDERED AS A GENERAL GUIDELINE. ALL DRAWING INFORMATIONPROVIDED IS BASED UPON FIELD DIMENSIONAL INFORMATION PROVIDED BYOTHERS - OWNERS INFORMATION AND PRELIMINARY DESIGN DOCUMENTS.THEREFORE SINCE SUCH PREPARED DRAWINGS ARE BASED UPONREASONABLE LEVEL OF VERIFICATION OF EXISTING CONDITIONS INCLUDINGFINISHES ETC. IN THE EVENT DIMENSIONAL VARIATIONS, OBSCUREDCONDITIONS NOT READILY VIEWED OR ACCESSIBLE UNTIL THE DEMOLITIONPROCESS HAS BEGUN, OR FINISH VARIATIONS ARE DISCOVERED -SUBSTANTIAL VARIATIONS SHALL BE REVIEWED IMMEDIATELY WITH THEARCHITECTS OFFICE. HOWEVER, MINOR FRACTIONAL VARIATIONS SHALL BERECORDED AS A MATTER OF COURSE AND DISPATCHED IN AN ORDERLYFASHION BY THE OWNER'S REPRESENTATIVE AND OTHER FIELD PERSONNEL.
2. THE DEMOLITION DRAWINGS ARE TO PROVIDE GENERAL DEMOLITIONGUIDELINES ONLY AND MAY NOT BE INCLUSIVE OF ALL ITEMS, MATERIALS,SYSTEMS, ETC., REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THESCHEDULED NEW CONSTRUCTION. IN THE EVENT THAT SYSTEMS/ITEMSDISCOVERED DURING DEMOLITION REQUIRE REMOVAL FOR IMPLEMENTATIONOF THE NEW WORK, IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLETESUCH REMOVAL, AND COORDINATE PROPOSED NEW CONSTRUCTION WITH SAIDREMOVAL.
3. GENERAL INTENTION OR SCOPE OF DEMOLITION WORK SHALL INCLUDEREMOVAL OF ALL EXISTING CONSTRUCTION, FINISHES, MECHANICAL SYSTEMS,ETC., AS REQUIRED FOR IMPLEMENTATION OF NEW PLAN AND FINISHES.
4. THE CONTRACTOR SHALL ENSURE THE TOTAL SAFETY, HEALTH, AND WELFAREOF ALL INDIVIDUALS WITHIN THE BUILDING PORTIONS IN WHICH DEMOLITION ANDSUBSEQUENT RECONSTRUCTION IS SCHEDULED TO OCCUR. PROVIDE ALLNECESSARY BARRICADES, PROTECTIVE SCREEN SHORING, ETC. ASNECESSARY.
5. ALL DEBRIS, EXISTING OR RESULTING FROM SCHEDULED CONSTRUCTIONDURING THE COURSE OF THE WORK, SHALL BE REMOVED FROM THE PROJECTAREA ON A DAILY BASIS. ALL SPACES INCLUDING STAIRS AND CORRIDORSSHALL BE MAINTAINED AND LEFT IN A BROOM CLEAN CONDITION DAILY.
6. ALL FIXTURES AND EQUIPMENT REMOVED AS SCHEDULED, SHALL BECONSIGNED TO THE GENERAL CONTRACTOR FOR REUSE AS SALVAGEDMATERIALS OR DISPOSAL AS REQUIRED. ALL INTERIOR DOORS AND ANYITEMS WHICH MAY BE DESIGNATED AS SALVAGEABLE DURING THECONSTRUCTION PERIOD, SHALL BE THE RESPONSIBILITY OF THE GENERALCONTRACTOR TO CATALOGUE AND PROVIDE STORAGE AND PROTECTIONFOR ALL SUCH MATERIALS INTENDED FOR REUSE.
7. ALL EXISTING ELECTRICAL, PLUMBING, AND HEATING SYSTEMS SHALL BEREMOVED, CAPPED, OR SEALED AS REQUIRED FOR THE CONTRACTOR TOIMPLEMENT THE NEWLY SCHEDULED WORK. SEE ELECTRICAL, HVAC, ANDPLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
8. IN THE EVENT THAT UNCOVERED CONDITIONS ARE CONSIDERED DEFECTIVE OROTHERWISE DISSIMILAR TO ANTICIPATED CONDITIONS, THE CONTRACTORSHALL NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY AND FOLLOWWITH A WRITTEN MEMORANDUM. PRIOR TO PROCEEDING WITH ANY BALANCEOF SCHEDULED WORK IN ANY GIVEN AREA, THE ARCHITECT/ENGINEER SHALLPERFORM INVESTIGATION SUFFICIENT TO DETERMINE STRUCTURAL INTEGRITYOF THE GIVEN COMPONENT.
9. ALL EXISTING WALL AREAS WHICH WERE PREVIOUSLY INTERSECTED BY OTHERWALLS, ETC. SHALL BE REPAIRED. REMOVE OLD MATERIALS TO A POINTWHERE NEW FINISH MATERIAL CAN BE EFFECTIVELY APPLIED TO A SOUND FIRMBASE. ALL OTHER CRACKED AND DAMAGED WALL AREAS SHALL BEREPAIRED SIMILARLY PRIOR TO THE APPLICATION OF FINAL WALL FINISHES.CONSIDER SPECIFICALLY REMOVAL OF ANY DRYWALL TO FRAME PRIOR TOPROCEEDING WITH FINAL FINISHES.
10. ALL FLOOR AREAS UPON WHICH PREVIOUS WALL LOCATIONS WERE BEARINGSHALL BE REPAIRED BY THE REMOVAL OF LOOSE DEBRIS (FOLLOWINGPARTITION REMOVAL), AND RESURFACE TO CAUSE THE NEW FINISH FLOORLEVEL TO BE A SMOOTH TRANSITION BETWEEN MAINTAINED FLOOR AREASAND REPAIRED POINTS.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL EXISTINGUTILITIES AND STRUCTURES BOTH VISIBLE AND OBSCURED BY OTHERASSEMBLIES, SUCH AS PAVEMENT, PLANTINGS, EARTHEN STRUCTURES,BUILDING, ETC., AND SHALL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALLPREPARATION REQUIREMENTS WHICH MAY RESULT FROM DAMAGE DURING THECONSTRUCTION OF THE WORK SCHEDULED BY THE DEVELOPMENT PLANS.
12. ALL DEMOLITION SCHEDULED BY THESE DOCUMENTS, OR AS MAY OTHERWISEBE REQUIRED BY PREVIOUSLY UNFORESEEN CONDITIONS, SHALL BECOORDINATED BY THE GENERAL CONTRACTOR WITH ALL TRADESMAN, ANDWITH FINAL DRAWINGS OR MODIFICATIONS THERETO, TO DETERMINE THE TRUEAND FINAL EXTENT OF THE REQUIRED WORK.
13. ALL EXISTING MEANS OF EGRESS AND ALL FIRE PROTECTION FEATURES ARETO BE MAINTAINED DURING ALL PHASES OF WORK.
GENERAL SITE NOTES:
1. THE GENERAL NOTES AND THE FOLLOWING DRAWINGS ANDSPECIFICATIONS SHALL APPLY TO ALL CONTRACTORS ANDSUBCONTRACTORS.
2. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL COMPLY WITH THEOCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA, LATESTAMENDMENTS).
3. THE CONTRACTOR SHALL MAINTAIN THAT THE ENGINEER, THE ARCHITECTAND THE CITY ENGINEER BE INFORMED OF CONSTRUCTION STATUS ON AWEEKLY BASIS, OR AS OTHERWISE REQUESTED. IN ORDER TO ALLOW FORPROPER INSPECTIONS OF THE WORK. ALL WORK IS SUBJECT TOINSPECTION, AND ANY PORTION OF THE WORK MAY BE REJECTED AT ANYTIME IF FOUND IN CONFLICT WITH AND CONTRARY TO THE CONSTRUCTIONDRAWINGS AND/OR SPECIFICATIONS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALLNECESSARY PERMITS AND INSPECTIONS. THE COST OF ALL PERMITS ANDINSPECTIONS SHALL BE TOTALLY BORN BY THE CONTRACTOR.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING ANDINSTALLING IN PLACE ALL SITE IMPROVEMENTS AS SHOWN, TO THESATISFACTION OF THE ARCHITECT AND/OR ENGINEER, AND/OR THE CITYENGINEER. ALL CONSTRUCTION SHALL BE GUARANTEED TO BE OF THEHIGHEST QUALITY STANDARDS.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANDREPLACING ALL DAMAGES TO UNDERGROUND UTILITIES AFFECTED BY THEWORK IN PROGRESS, OR ANY APPURTENANCES ENCOUNTERED.
7. RESPECTIVE UTILITY INSTALLERS SHALL BE RESPONSIBLE FOR PAYING ALLCOSTS FOR BRINGING NEW UTILITY SERVICES TO THE BUILDING. THESEINCLUDE BUT ARE NOT NECESSARILY LIMITED TO TAP FEES, IMPACT FEES,TRANSFORMER COSTS AND PRIMARY SERVICE LINE INSTALLATION FEES.
8. THE CONTRACTOR SHALL INVESTIGATE AND LOCATE ALL UTILITIES PRIORTO CONSTRUCTION AS FURTHER VERIFICATION TO SURVEY DATAPROVIDED. IN THE EVENT THAT VARIATIONS ARE FOUND, THE SAMEINFORMATION SHALL BE FURNISHED IMMEDIATELY AND IN WRITTEN FORMATTO THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK ASORIGINALLY SCHEDULED.
9. VERIFICATION OF AND COMPLIANCE WITH ALL APPLICABLE LOCAL, CITYAND/OR STATE GOVERNING AGENCY REQUIREMENTS IS THERESPONSIBILITY OF EACH CONTRACTOR.
10. THE LATEST EDITION OF THE STATE'S DEPARTMENT OF TRANSPORTATIONCONSTRUCTION AND MATERIALS SPECIFICATIONS (OR DEPARTMENT OFHIGHWAY REQUIREMENTS) ARE APPLICABLE TO THESE IMPROVEMENTS,UNLESS OTHERWISE SPECIFICALLY INDICATES.
11. ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED AS REQUIRED, WITHSPECIFIC ALLOWANCES MADE FOR SETTLEMENTS OF MATERIALS.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE ANDREPAIR OF ANY AND ALL TRENCH SETTLEMENTS FOR A PERIOD OF ONEYEAR FOLLOWING FINAL ACCEPTANCE OF THE WORK BY THE OWNER OFRESPONSIBLE AUTHORITY OF REPRESENTATIVES.
13. WHERE EXISTING PAVEMENT, DRIVEWAYS, PARKING AREAS, CURBS,GUTTERS, BERM STONE, SIDEWALKS, WATER LINES, GAS LINES, SANITARYOR STORM SEWER CATCH BASINS, MANHOLES AND RELATED ASSEMBLIES,DRAINS, FIELD TILES, CONDUIT PIPING, MAIN BOXES, TRAFFIC SIGNS, GATEVALVES, FIRE HYDRANTS, OR OTHER EXISTING FACILITIES ARE REMOVEDOR OTHERWISE DISTURBED DURING EXECUTION OF THE SCHEDULEDIMPROVEMENTS, SUCH FACILITIES SHALL BE REPLACED IN A CONDITION ATLEAST "AS GOOD" AS FOUND PRIOR TO COMMENCING THE WORK, SUCHRESPONSIBILITY SHALL BE OF THE CONTRACTOR.
14. THE CONTRACTOR SHALL REGRADE, SEED AND MULCH ALL DISTURBEDAREAS, OR OTHERWISE PROTECT ALL DISTURBED AREAS AS INDICATED.REFER TO LANDSCAPING PLAN FOR ADDITIONAL INFORMATION.
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
10/08/12
A001
ABBREVIATIONSSYMBOLS &
NOTES
Issue Description Date
G
E
SOU
TH L
IBER
TY S
TREE
T (5
0' R/
W)
E/P
E/P
E/P
E/P
E/P
VIL
LAG
E O
F PO
WEL
L O
HIO
D.B
. 635
, PG
. 129
3.01
5 A
C.PA
RCEL
NO
. 319
4310
2024
000
EXISTING 2-STORY STRUCTURE153 SOUTH LIBERTY STREET
POWELL, OHIO
2 STORY ADDITION576 SF
EXISTINGPARKING
EXISTING DRIVE
5'-
0"
general notes: demolition1. COORDINATE LOCATIONS OF HIDDEN OR
BURIED UTILITIES BEFORE DEMOLITION2. PROTECT ALL FINISH SURFACES
IMMEDIATELY ADJACENT TOSURFACES/ELEMENTS TO BE REMOVED ORDEMOLISHED
3. VERIFY LOCATION OF IRRIGATION CONTROLSNOTED TO DETERMINE IF CONTROLSRELOCATION IS REQUIRED
4. COORDINATE STORAGE AND/OR DISPOSALOF DOORS AND WINDOWS TO BE REMOVED
5. COORDINATE STORAGE OF ELEMENTS TO BEREMOVED FOR RE-USE.
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
10/08/12
C101
SITE PLAN
1/8" = 1'-0"Site
Issue Description Date
- 153 South Liberty Street Powell, Ohio
FOR REFERENCE ONLY
12
'-0
"
4" CONCRETE SLABOVER3" MIN GRAVELOVER 6 MIL VAPORBARRIER W/6X6W1.4X1.4 WWF TOP
8" CMU W/#5 @ 32" O.C.
CONTINUOUS ISOLATIONJOINT
1'-8" X 12" DEEPW/(2) #5 CONTINUOUS @ BOTTOM
E
S101
1'-8" 1'-8"
1'-
8"
TOOLEDCONTROL JOINT
16'-0"
12
'-0
"
INDICATES LOCATIONOF CONCRETE ANCHOR(1/2" x16" 'J'-BOLT) @48" O.C. IN CONCRETEFILLED CELL
CONTINUOUS NAILERFASTENED TOEXISTING RIM BOARD
WO
OD
I-J
OIS
TS
@ 1
6" O
.C.
12
" DE
EP
PR
E-E
NG
INE
ER
ED
CO
MP
OS
ITE
LSL RIM BOARD
3/4" T&G OSBGLUED AND
NAILED W/10dSPIRAL OR
RING SHANKS
F
S101
G
S101
2X8 ACQ SILL
8" CMU STEM WALLPER FOUNDATIONPLAN
2'-
11
"4
'-0
"4
'-0
"8
"
2'-
11
"4
'-0
"4
'-0
"8
"
WALL FRAMING2X4@12"O.C.
WALL FRAMING2X4@16"O.C.
A
A501
A
A501
12
'-0
"
WO
OD
I-J
OIS
TS
@ 1
6" O
.C.
12
" DE
EP
PR
E-E
NG
INE
ER
ED
CO
MP
OS
ITE
LSL RIM BOARD
3/4" T&G OSBGLUED AND
NAILED W/6dSPIRAL OR
RING SHANKS(2)2x10 HEADERW/2 JACKS & 1KING STUD
G
S101
(2)2x10HEADER
W/2 JACKS &1 KING STUD
(2)2x8HEADERW/1 JACK & 1
KING STUD
PROVIDE SOLIDWALL 'TEE' INEXISTING WALLFOR CONNECTIONOF NEW WALLFRAMING TOEXISTING WALLFRAMING
PROVIDE SOLIDWALL 'TEE' IN
EXISTING WALL FORCONNECTION OF
NEW WALL FRAMINGTO EXISTING WALL
FRAMING
WALL FRAMING2X4@12"O.C.
WALL FRAMING2X4@16"O.C.
TR
USS
ES
@ 2
4" O
.C.
PR
E-E
NG
INE
ER
ED
WO
OD
2X8 FASCIA
(2) 2x8 HEADERW/1 JACK & 1 KINGSTUD
OV
ER
FR
AM
ING
@ 2
4" O
.C.
PR
E-E
NG
INE
ER
ED
WO
DD
TR
USS
2x8 HEADER
8" F.V. 16'-0" FACE OF ROUGH FRAMING 8" F.V.
12
'-0
" FA
CE
OF
FR
AM
ING
8" F
.V.
BUILT-OVER ROOFON EXISTING ROOFDECK PER TRUSSMANUFACTURER
2xRIDGEBLOCKING PERTRUSSMANUFACTURER
NOTE:EAVE/OVERHANGDIMENSIONS TOMATCH EXISTING
(2) 2x8 HEADERW/1 JACK & 1 KINGSTUD
(2) 2x8 HEADERW/1 JACK & 1 KING
STUD
PROVIDE SOLIDWALL 'TEE' INEXISTING WALLFOR CONNECTIONOF NEW WALLFRAMING TOEXISTING WALLFRAMING
PROVIDE SOLIDWALL 'TEE' IN
EXISTING WALLFOR CONNECTION
OF NEW WALLFRAMING TO
EXISTING WALLFRAMING
7 /16" APARATED SHEATHING
7 /16" APARATED SHEATHING
1'-8"
1'-
0"
4"
2" R10 RIGID FOAMBOARD
ASPHALTIC WATERPROOFING
8" CONCRETE BLOCK W/#5 BARVERTICAL @ 32" O.C. (GROUTCELL SOLID) & TRUSS TYPEHORIZ REINFORCEMENT EVERY3RD COURSE
(2) # 5 BARS CONTINUOUS
#5 BARS @ 12" O.C. CONT
4" DIA PERFORATED DRAIN PIPEIN GEO-TEXTILE WRAPPED GRAVEL
CAST IN PLACE CONCRETE FOOTING
4" GRAVEL BASE
6MIL VAPOR BARRIER
1/2" (MIN) ISOLATION JOINT
4" CONCRETE SLAB
3"
3"
CONT HORIZONTAL LADDERTYPEJOINT REINFORCEMENT @ 24"O.C. VERT
1ST FLOOR100' - 0"
T.O. BASEMENTWALLS
98' - 9 7/8"
8" CONCRETE BLOCK W/#4BAR VERTICAL @ 24" O.C.(GROUT CELL SOLID) & TRUSSTYPE HORIZ REINFORCEMENTEVERY 3RD COURSE
1/2" DIA x16" 'J' BOLT @ 48" O.C.SEE FOUNDATION PLAN
ASPHALTIC WATERPROOFING
2" RIGID FOAMBOARD
EXPOSED BLOCK (LAST COURSE@ MINIMUM) TO BE SPLIT FACEBLOCK TO MATCH EXISTING
GALVANIZED FLASHING
LSL RIM BOARD PER JOISTMANUFACTURER
3/4" T&G OSB GLUED & FASTENEDW/6d RING OR SPIRAL SHANKGALVANIZED NAILS @ 6" O.C. @EDGES & 8" O.C. IN FIELD
2X4 SOLE PLATE OVER SILL SEAL
2X6 ACQ SILL, CONT
TJI PER JOIST MANUFACTURER
BLOCKING SUPPORT PER JOISTMANUFACTURER
2X4 BLOCKING @ 32" O.C.
2ND FLOOR110' - 1 5/8"
2ND FLOORBEARING
109' - 1"
CONTINUOUS DOUBLE PLATE TYPICAL
FLOOR FRAMING PER FRAMING PLANSW/(2) H2.5A PER END
2X4 BLOCKING @ 32" O.C.
LSL RIM BOARD
2X4 SUPPORT BLOCKING @ 24" O.C.
3/4" T&G APA RATED OSB SHEATHINGGLUED & FASTENED W/10d RING ORSPIRAL SHANK NAILS @ 6" O.C. @ EDGE &12" O.C. IN FIELD
(2) 16d @ 24" O.C. MAX
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
06/24/14
S101
FRAMINGPLANS AND
DETAILS
1/4" = 1'-0"S101foundation planA
1/4" = 1'-0"S101first floor framing planB
Issue Description Date
1/4" = 1'-0"S101second floor framing planC
1/4" = 1'-0"S101roof framing planD
1 1/2" = 1'-0"S101section detail - foundationE
1 1/2" = 1'-0"S101section detail - 1st floorF
1 1/2" = 1'-0"S101section detail 2nd floorG
UP
UP
DN
77'-4"
16'-0" 8'-8" 23'-0" 17'-8" 12'-0"
30
'-8
"
17
'-8
"1
3'-
0"
30
'-8
"
2'-
0"
7'-
8"
16
'-0
"5
'-0
"
HEATEDCRAWLSPACE
8'-0" 3'-4" 11'-8"
REMOVE PORTIONOF EXISTINGBLOCK WALL FORNEW CRAWL SPACEACCESS - SEEBUILDING SECTION
EXISTING CRAWLSPACE ACCESS
INDICATES EXTENTS OFEXISTING CRAWL SPACE
RECEPTION
OFFICE 3
OFFICE 2
OFFICE 1
CONFERENCE
LOUNGE
LAV WORK ROOM
CORRIDOR
CLOSET
ENTRY
77'-4"
16'-0" 31'-8" 17'-8" 12'-0"
77'-4"
16'-0" 8'-8" 23'-0" 29'-8"
30
'-8
"
13
'-0
"1
7'-
8"
30
'-8
"
5'-
0"
16
'-0
"7
'-8
"2
'-0
"
16'-0 1/2" 48'-11 1/2" 12'-4"
15
'-4
"7
'-8
"
A103
A
REMOVE SIDING, TRIMAND WEATHER BARRIER
DOWN TO STRUCTURALSHEATHING
DIMENSIONS IN FIELD
+/- 16'-2" COORDINATE
REMOVE WINDOW, HEADERWALL FRAMING BELOWAND PORTION OF ADJACENTWALL FRAMING INDICATED
F
S101
1'-0"
CONDENSING UNITSTO BE RELOCATED
graphic legend: demolitionINDICATES ELEMENT TO BEREMOVED
INDICATES GENERAL EXTENTS OFSIDING/FINISH ROOFING TO BEREMOVED
INDICATES EXTENTS OF WALLOR ROOF FRAMING/SHEATHINGTO BE REMOVED (SEEELEVATIONS)
general notes: demolition1. COORDINATE LOCATIONS OF HIDDEN OR
BURIED UTILITIES BEFORE DEMOLITION2. PROTECT ALL FINISH SURFACES
IMMEDIATELY ADJACENT TOSURFACES/ELEMENTS TO BE REMOVED ORDEMOLISHED
3. VERIFY LOCATION OF IRRIGATION CONTROLSNOTED TO DETERMINE IF CONTROLSRELOCATION IS REQUIRED
4. COORDINATE STORAGE AND/OR DISPOSALOF DOORS AND WINDOWS TO BE REMOVED
5. COORDINATE STORAGE OF ELEMENTS TO BEREMOVED FOR RE-USE.
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
06/08/14
B101
EXISTINGBASEMENTAND FIRST
FLOOR PLAN
1/4" = 1'-0"basement plan - existing
1/4" = 1'-0"first floor plan - existing
EXISTING IRRIGATIONCONTROLS TO REMAIN
CONDENSING UNITS TOBE DISCONNECTED FORRELOCATION - SEEPROPOSED PLAN/SITEPLAN
Issue Description Date
DN
A103
A
REMOVE WINDOW, HEADERWALL FRAMING BELOWAND PORTION OF ADJACENTWALL FRAMING INDICATED
1'-0"
DIMENSIONS IN FIELD
+/- 16'-2" COORDINATE
REMOVE SIDING, TRIMAND VAPOR BARRIER
DOWN TO STRUCTURALSHEATHING
2'-5"
REQUIRED DIMENSIONS IN FIELD
18'-0" COORDINATE
10" / 12" 10" / 12"
4" /
12"
4" /
12"
4" /
12"
10" /
12"
10" /
12"
10" / 12" 10" / 12"
10" /
12"
10" /
12"
4" / 12"
PORTION OF EAVE TO BE REMOVEDPROVIDE 2X4 BLOCKS BETWEENTRUSSES OR RAFTERS ON TOPPLATE OF EXISTING WALL
GENERAL AREA OF FINISHROOF TO BE REMOVED DOWN TO STRUCTURALSHEATHING
graphic legend: demolitionINDICATES ELEMENT TO BEREMOVED
INDICATES GENERAL EXTENTS OFSIDING/FINISH ROOFING TO BEREMOVED
INDICATES EXTENTS OF WALLOR ROOF FRAMING/SHEATHINGTO BE REMOVED (SEEELEVATIONS)
general notes: demolition1. COORDINATE LOCATIONS OF HIDDEN OR
BURIED UTILITIES BEFORE DEMOLITION2. PROTECT ALL FINISH SURFACES
IMMEDIATELY ADJACENT TOSURFACES/ELEMENTS TO BE REMOVED ORDEMOLISHED
3. VERIFY LOCATION OF IRRIGATION CONTROLSNOTED TO DETERMINE IF CONTROLSRELOCATION IS REQUIRED
4. COORDINATE STORAGE AND/OR DISPOSALOF DOORS AND WINDOWS TO BE REMOVED
5. COORDINATE STORAGE OF ELEMENTS TO BEREMOVED FOR RE-USE.
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
06/08/14
B102
SECONDFLOOR ANDROOF PLAN -
EXISTING
1/4" = 1'-0"second floor plan - existing
1/4" = 1'-0"roof plan existing
Issue Description Date
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
BASEMENT/FOUNDATION90' - 9 7/8"
2ND FLOORBEARING109' - 1"
ROOF BEARING118' - 2 5/8"
T.O. BASEMENTWALLS
98' - 9 7/8"
ADD ROOF BRNG118' - 2 3/4"
8'-
0"
9'-
1"
1'-
0 1
/2
"8
'-1
"
CONDENSERS TO BEDISCONNECTED FORRELOCATION
REMOVE EXISTING WINDOWAND HEADER
REMOVE WALL SHEATHING AND FRAMING BELOW WINDOW
GENERAL EXTENTS OF ROOFOVERHANG (FIN ROOF, GUTTER,FASCIA & SOFFIT) TO BE REMOVED
1'-0" +/-16'-2" F.V. 1'-0"
18'-2 1/2" FIELD VERIFY
REMOVE EXISTINGWINDOW & HEADER
REMOVE WALL SHEATHINGAND FRAMING BELOW WINDOW
GENERAL EXTENTS OFSIDING TO BE REMOVED
10" / 12"10" /
12"
10" / 12" 10" / 12"
10" / 12"
HE
AD
HE
IGH
T
7'-
10
" TY
PIC
AL
FIBER CEMENT LAP SIDING, TYPICAL
ASPHALT ROOFING SHINGLES, TYPICAL SHINGLE-OVER RIDGE VENT, TYPICAL
BOARD & BATTEN SIDING
HE
AD
HE
IGH
T
7'-
0" T
YP
ICA
L
+/- 3'-2"
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
BASEMENT/FOUNDATION90' - 9 7/8"
2ND FLOORBEARING109' - 1"
ROOF BEARING118' - 2 5/8"
T.O. BASEMENTWALLS
98' - 9 7/8"
ADD ROOF BRNG118' - 2 3/4"
10" / 12"
10" / 12"
10" /
12"
4" /
12"
HE
AD
HE
IGH
T
7'-
10
" TY
PIC
AL
HE
AD
HE
IGH
T
7'-
0"
TY
PIC
AL
general notes: demolition1. COORDINATE LOCATIONS OF HIDDEN OR
BURIED UTILITIES BEFORE DEMOLITION2. PROTECT ALL FINISH SURFACES
IMMEDIATELY ADJACENT TOSURFACES/ELEMENTS TO BE REMOVED ORDEMOLISHED
3. VERIFY LOCATION OF IRRIGATION CONTROLSNOTED TO DETERMINE IF CONTROLSRELOCATION IS REQUIRED
4. COORDINATE STORAGE AND/OR DISPOSALOF DOORS AND WINDOWS TO BE REMOVED
5. COORDINATE STORAGE OF ELEMENTS TO BEREMOVED FOR RE-USE.
graphic legend: demolitionINDICATES ELEMENT TO BEREMOVED
INDICATES GENERAL EXTENTS OFSIDING/FINISH ROOFING TO BEREMOVED
INDICATES EXTENTS OF WALLOR ROOF FRAMING/SHEATHINGTO BE REMOVED (SEEELEVATIONS)
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
06/08/14
B201
EXTERIORELEVATIONS -
EXISTING
1/4" = 1'-0"north elevation - existing
1/4" = 1'-0"east elevation - existing
Issue Description Date
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
BASEMENT/FOUNDATION90' - 9 7/8"
2ND FLOORBEARING109' - 1"
ROOF BEARING118' - 2 5/8"
T.O. BASEMENTWALLS
98' - 9 7/8"
ADD ROOF BRNG118' - 2 3/4"
10" / 12" 10" / 12"
10" /
12"
10" /
12"
HARDI-PLANK LAP SIDING
HE
AD
HE
IGH
T
7'-
10
" TY
PIC
AL
HE
AD
HE
IGH
T
7'-
0" T
YP
ICA
L
ASPHALT SHINGLES, TYPICALASPHALT SHINGLES, TYPICAL
BOARD & BATTEN SIDING
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
BASEMENT/FOUNDATION90' - 9 7/8"
2ND FLOORBEARING109' - 1"
ROOF BEARING118' - 2 5/8"
T.O. BASEMENTWALLS
98' - 9 7/8"
ADD ROOF BRNG118' - 2 3/4"
10" / 12"
ASPHALT SHINGLES, TYPICAL HARDI-PLANKLAP SIDING, TYPICAL
graphic legend: demolitionINDICATES ELEMENT TO BEREMOVED
INDICATES GENERAL EXTENTS OFSIDING/FINISH ROOFING TO BEREMOVED
INDICATES EXTENTS OF WALLOR ROOF FRAMING/SHEATHINGTO BE REMOVED (SEEELEVATIONS)
general notes: demolition1. COORDINATE LOCATIONS OF HIDDEN OR
BURIED UTILITIES BEFORE DEMOLITION2. PROTECT ALL FINISH SURFACES
IMMEDIATELY ADJACENT TOSURFACES/ELEMENTS TO BE REMOVED ORDEMOLISHED
3. VERIFY LOCATION OF IRRIGATION CONTROLSNOTED TO DETERMINE IF CONTROLSRELOCATION IS REQUIRED
4. COORDINATE STORAGE AND/OR DISPOSALOF DOORS AND WINDOWS TO BE REMOVED
5. COORDINATE STORAGE OF ELEMENTS TO BEREMOVED FOR RE-USE.
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
06/08/14
B202
EXTERIORELEVATIONS -
EXISTING
1/4" = 1'-0"south elevation - existing
1/4" = 1'-0"west elevation - existing
Issue Description Date
UP
DN
UP
general notes: plan1. GENERAL CONTRACTOR TO VERIFY THAT EXISTING
CONDITIONS ARE AS SHOWN. SHOULD ACTUAL CONDITIONSDIFFER, G.C IS TO INFORM ARCHITECT IN WRITINGIMMEDIATELY
2. NEW FINISH SIDING AND TRIMS TO MATCH EXISTING3. NEW WINDOWS TO MATCH EXISTING4. NEW DOORS TO MATCH EXISTING5. NEW INTERIOR FLOOR FINISHES TO BE SELECTED BY
OWNER
finish notes:1. NEW DOOR DESIGN TO MATCH
EXISTING DOOR DESIGN2. CONTRACTOR SHALL COORDINATE
ALL FINISHES AND MATERIALS WITHOWNER
B
A501
B
A501
A
A501
A
A501
NEW GWB FINISHOVER EXISTINGWALL SHEATHINGON EXISTING WALL
NEW DOOR TOMATCH EXISTING
RELOCATEDCONDENSINGUNITS - SEEMECHANICAL
NEW CONDENSINGUNIT - SEE MECHANICAL
RECEPTION
109
OFFICE 3
108OFFICE 2
107
OFFICE 1
106
CORRIDOR
105
CONFERENCE
104
WORK ROOM
103
LAV
102
ENTRY
208
LOUNGE
101
NEW OFFICE 01
110
16'-0"
1'-0" 4'-3" 7'-6" 4'-3"
12
'-0
"
8'-
0"
4'-
0"
8'-
0"
4'-
0"
EQ EQ
A
A A
A
W1
W2
01
B
A501
B
A501
A
A501
A
A501
NEW CRAWL SPACE TO BEINSULATED/HEATED AREA
REMOVE BLOCKSIN EXISTING WALL
FOR ACCESS TO NEWCRAWL SPACE
EXISTING CRAWL SPACE
EXISTING OPENING TOEXISTING CRAWL SPACE
12
'-0
"
+/- 8'-0" 3'-4"
1'-0" 16'-0"
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
10/08/12
A101
BASEMENTAND FIRST
FLOOR PLAN
Issue Description Date
1/4" = 1'-0"first floor plan
1/4" = 1'-0"basement plan
DN
B
A501
B
A501
12
'-0
"
16'-0"
A
A501
A
A501
1'-
3"
1'-1" 1'-1"
EXTERIOR FACE OF WALLBELOW
GUTTER
SHINGLE-OVERRIDGE VENT
BUILT-OVERROOF
NEW VALLEYFLASHING
NEW VALLEYFLASHING
NEW VALLEYFLASHING
NEW VALLEYFLASHING
EXTERIOR FACE OF WALLBELOW
GUTTER
10" / 12"10" / 12"
4" /
12"
4" /
12"
10" /
12"
10" /
12"
general notes: plan1. GENERAL CONTRACTOR TO VERIFY THAT EXISTING
CONDITIONS ARE AS SHOWN. SHOULD ACTUAL CONDITIONSDIFFER, G.C IS TO INFORM ARCHITECT IN WRITINGIMMEDIATELY
2. NEW FINISH SIDING AND TRIMS TO MATCH EXISTING3. NEW WINDOWS TO MATCH EXISTING4. NEW DOORS TO MATCH EXISTING5. NEW INTERIOR FLOOR FINISHES TO BE SELECTED BY
OWNER
general notes: roof plan1. GENERAL CONTRACTOR TO VERIFY THAT EXISTING
CONDITIONS ARE AS SHOWN. SHOULD ACTUALCONDITIONS DIFFER, G.C IS TO INFORM ARCHITECT INWRITING
2. NEW FINISH ROOFING TO MATCH EXISTING3. NEW FLASHING AND DRIP EDGE TO MATCH EXISTING4. NEW RIDGE VENT TO MATCH EXISTING5. NEW SOFFIT AND SOFFIT VENTS TO MATCH EXISTING
finish notes:1. NEW DOOR DESIGN TO MATCH
EXISTING DOOR DESIGN2. CONTRACTOR SHALL COORDINATE
ALL FINISHES AND MATERIALS WITHOWNER
B
A501
B
A501
A
A501
A
A501
NEW GWB FINISHOVER EXISTING
WALL SHEATHINGON EXISTING WALL
NEW DOOR TOMATCH EXISTING
OFFICE 5
204
OFFICE 6
206
CORRIDOR
202
OFFICE 4
203
OPEN OFFICE
201
LAV
200
CLOSET
113
NEW OFFICE 02
207
02
A
A A
A
16'-0"
12
'-0
"
8'-
0"
4'-
0"
1'-0" 4'-3" 7'-6" 4'-3"
12
'-0
"
8'-
0"
4'-
0"
W1
W2
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
10/08/12
A102
SECONDFLOOR ANDROOF PLAN
1/4" = 1'-0"roof plan
Issue Description Date
1/4" = 1'-0"second floor plan
EXTEND ROOFSHEATHING SOLIDBELOW RIDGE VENTFOR DISTANCE OF 24"EACH SIDE OFCOMMON WALLS
EXTEND ROOF SHEATHINGSOLID BELOW CONTINUOUSRIDGE VENT FOR DISTANCEOF 24" EACH SIDE OFDRAFTSTOPPING AND FIRERATED WALLS. BLOCK RIDGEVENT TO STOP PASSAGE OFAIR BETWEEN UNITS
PLYWOODGUSSET
MINIMUM 2" AIR SPACE
WOOD TRUSS
SHINGLES OVER ROOFINGFELT PER SPECIFICATIONS
FILTER VENT 'RIDGE FILTERSHINGLE VENT'
SHINGLES NAILED OVER RIDGEVENT IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS
1" AIR SPACE EA. SIDE
WOOD TRUSS & RIDGE BEAM
SHINGLES OVER ROOFING FELTPER SPECIFICATIONS
FILTER VENT 'RIDGE FILTERSHINGLE VENT'
SHINGLES NAILED OVER RIDGEVENT IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS
2"
1"
VALLEY FLASHINGAS SPECIFIED WITH1" 'V' CRIMP
BEND BACK EDGEOF FLASHING 1/2"CONTINUOUS EACHSIDE AS SHOWN
ROOF SHEATHING ASSPECIFIED
15# ROOFING FELTOVER ICE GUARD ASSPECIFIED
36" WIDE ICE GUARDUNDERLAYMENTCENTERED ON VALLEY
COMPOSITION SHINGLES- CROP TOP CORNER OFEND SHINGLES 45 3/4" x3/4" BOTH SIDES OFVALLEY
5"
1'-0"
INTERIOR
EXTERIOR3'-2" +/- REMOVE WINDOW AND ALL
COMPONENTS IN SHADED AREAAND BELOW FOR INSTALLATIONOF NEW INTERIOR DOOR
W1 EXISTING EXTERIOR WALLCONVERTED TO INTERIOR WALL
W2 EXTERIOR WALL
F1 UNRATED FLOORCEILING ASSEMBLY
R1 ROOF CEILING ASSEMBLY
2X4 @ 16" O.C. WITH SINGLE SOLEPLATE AND TWO TOP PLATES(EXISTING)
1/2" GYPSUM BOARD (EXISTINGINTERIOR)
7/16" OSB SHEATHING (EXISTING)
1/2" GYPSUM WALLBOARD
1/2" GYPSUM WALLBOARD
2X4 @ 16" O.C. WITH SINGLE SOLEPLATE AND TWO TOP PLATES
7/16" OSB SHEATHING
FIBER CEMENT LAPPED SIDING WITH5" EXPOSURE (TO MATCH EXISTING)
5/8" GYPSUM WALLBOARD
NOMINAL 12" TJI JOISTS @16" O.C.
3/4" T&G APA RATED SHEATHINGGLUED & NAILED WITH 6d RING ORSPIRAL SHANK NAILS @ 8" O.C. INFIELD & 6" O.C. @ EDGES
5/8" GYPSUM WALLBOARD
PRE-ENGINEERED, PRE-MANUFACTURED WOOD ROOFTRUSSES @ 24" O.C.
1/2" MIN APA RATED ROOFSHEATHING NAILED WITHGALVANIZED 6d RING OR SPIRALSHANK NAILS @ 6" O.C. IN FIELD & 4"O.C. @ EDGES
WEATHER BARRIER
6 MIL VAPOR BARRIER
R19 BATT INSULATION
15# FELT PAPER
ASPHALT SHINGLES (TO MATCHEXISTING)
R30 INSULATION
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
06/25/14
A103
PLAN DETAILSAND
SCHEDULES 1" = 1'-0"A103
ridge and hip vent detailB
1" = 1'-0"A103valley flashingC
3/4" = 1'-0"A103plan detailA
Door ScheduleMark Location Width Height
FireRating
HardwareSet Remarks
01 NEW OFFICE 01 3' - 0" 6' - 8" NA PRIVACY DOOR, DOOR FRAME AND HARDWARETO MATCH EXISTING
02 NEW OFFICE 02 3' - 0" 6' - 8" NA PRIVACY DOOR, DOOR FRAME AND HARDWARETO MATCH EXISTING
Window ScheduleMark Height Width Comments
A 6' - 0" 2' - 6" NEW WINDOWS TO MATCH EXISTING
Issue Description Date
1 1/2" = 1'-0"A103ASSEMBLY TYPESD
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
BASEMENT/FOUNDATION90' - 9 7/8"
2ND FLOORBEARING109' - 1"
ROOF BEARING118' - 2 5/8"
T.O. BASEMENTWALLS
98' - 9 7/8"
B
A501
ADD ROOF BRNG118' - 2 3/4"
NEW RIDGE VENTTO MATCH EXISTING
NEW FINISH ROOFINGTO MATCH EXISTING
NEW FASCIA ANDSOFFIT TO MATCHEXISTING
NEW GUTTERS/DOWNSPOUTSTO MATCH EXISTING
NEW SIDING & TRIMTO MATCH EXISTING
NEW WINDOWS & TRIMTO MATCH EXISTING
SPLIT FACE BLOCKTO MATCH EXISTING
EXISTING CONDENSERSRELOCATED
NEW ADDITION
EXTENT OF
NEW CRAWL SPACE
EXTENT OF
D
A501
A202
ATYP
G
S101
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
BASEMENT/FOUNDATION90' - 9 7/8"
2ND FLOORBEARING109' - 1"
ROOF BEARING118' - 2 5/8"
8'-
0"
9'-
1"
1'-
0 1
/2
"8
'-1
"
T.O. BASEMENTWALLS
98' - 9 7/8"
ADD ROOF BRNG118' - 2 3/4"
A
A501
WIN
DO
W H
D H
T
7'-
10
" N
EW
WIN
DO
W H
D H
T
7'-
0"
NE
W
10" / 12"10" /
12"
EXTENT OF NEW ADDITIONRELOCATEDEXISTING
CONDENSERS
NEWCONDENSER
SEE MECHANICALDRAWINGS
NEW RIDGE VENT TO MATCH EXISTING
NEW FINISH ROOFING TO MATCH EXISTING
NEW FASCIA AND SOFFIT TO MATCH EXISTING
NEW SOFFIT RETURN TO MATCH EXISTING
NEW GUTTERS/DOWNSPOUTSTO MATCH EXISTING
NEW SIDING & TRIMTO MATCH EXISTING
NEW WINDOWS & TRIMTO MATCH EXISTING
SPLIT FACE BLOCKTO MATCH EXISTING
10" / 12"10" /
12"
10" /
12"
10" / 12"
10" / 12"
A202
ATYP
general notes: building elevations1. PROVIDE SPLIT FACE BLOCK AT LAST COURSE OF FOUNDATION STEM WALLS TO
MATCH EXISTING2. NEW FINISH SIDING (PRE-FINISHED HARDI-PLANK AND TRIM) TO MATCH EXISTING3. NEW EXTERIOR WINDOW TRIM TO MATCH EXISTING WINDOW EXTERIOR TRIM.
PROVIDE NEW 'PEDIMENT' TYPE TRIM AT WINDOWS TO MATCH EXISTING. (EXISTINGWINDOWS ARE NOT SHOWN WITH TRIM) - SEE DETAIL A/A202
4. NEW EAVE TO MATCH EXISTING WITH LIKE FASCIA SIZE, PROFILE AND FINISH, SAMEDRIP EDGE (IF ANY), SAME GUTTER PROFILE AND SAME SOFFIT MATERIAL
5. PROVIDE SAME SIZE AND PROFILE OF FRIEZE BOARD TO MATCH EXISTING6. PROVIDE SAME SOFFIT RETURNS AT GABLE END TO MATCH EXISTING7. NEW DOWNSPOUTS SIZE AND PROFILE TO MATCH EXISTING8. NEW PAINT COLOR(S) TO BE COORDINATED WITH OWNER AND ARCHITECT
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
10/08/12
A201
EXTERIORELEVATIONS
1/4" = 1'-0"east elevation
1/4" = 1'-0"north elevation
EXTENT OF EXISTING CRAWL SPACE
EXTENT OF NEW CRAWLSPACE
Issue Description Date
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
BASEMENT/FOUNDATION90' - 9 7/8"
2ND FLOORBEARING109' - 1"
ROOF BEARING118' - 2 5/8"
T.O. BASEMENTWALLS
98' - 9 7/8"
B
A501
ADD ROOF BRNG118' - 2 3/4"
EXTENT OF NEW ADDITION
EXTENT OF NEW CRAWL SPACE
SPLIT FACE BLOCKTO MATCH EXISTING
NEW SIDING ANDTRIM TO MATCH
EXISTING
NEW WINDOW ANDTRIM TO MATCH
EXISTING
NEW FASCIA TOMATCH EXISTING
NEW GUTTER
NEW FINISH ROOFINGTO MATCH EXISTING
NEW RIDGE VENT TOMATCH EXISTING
8"
5"
3"
5/4" X 4"FIBER CEMENTBOARD TRIM
5/4" X 8"FIBER CEMENTBOARD TRIMCUT ASINDICATED
3/4" FIBERCEMENTBOARD TRIMCAP
GALVANIZEDFLASHINGBEHIND SIDING
general notes: building elevations1. PROVIDE SPLIT FACE BLOCK AT LAST COURSE OF FOUNDATION STEM WALLS TO
MATCH EXISTING2. NEW FINISH SIDING (PRE-FINISHED HARDI-PLANK AND TRIM) TO MATCH EXISTING3. NEW EXTERIOR WINDOW TRIM TO MATCH EXISTING WINDOW EXTERIOR TRIM.
PROVIDE NEW 'PEDIMENT' TYPE TRIM AT WINDOWS TO MATCH EXISTING. (EXISTINGWINDOWS ARE NOT SHOWN WITH TRIM) - SEE DETAIL A/A202
4. NEW EAVE TO MATCH EXISTING WITH LIKE FASCIA SIZE, PROFILE AND FINISH, SAMEDRIP EDGE (IF ANY), SAME GUTTER PROFILE AND SAME SOFFIT MATERIAL
5. PROVIDE SAME SIZE AND PROFILE OF FRIEZE BOARD TO MATCH EXISTING6. PROVIDE SAME SOFFIT RETURNS AT GABLE END TO MATCH EXISTING7. NEW DOWNSPOUTS SIZE AND PROFILE TO MATCH EXISTING8. NEW PAINT COLOR(S) TO BE COORDINATED WITH OWNER AND ARCHITECT
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
06/08/14
A202
EXTERIORELEVATION -PROPOSED
1/4" = 1'-0"WEST ELEVATION -PROPOSED
1" = 1'-0"A202WINDOW TRIM DETAILA
Issue Description Date
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
ADD ROOF BRNG118' - 2 3/4"
ACCESS
10
'-1
1/
2"
+/-
8'-
1"
CIP CONCRETE FOOTING
8" CMU WALL
4" SLAB OVER 6 MILVAPOR BARRIER OVER4" GRAVEL
NEW CRAWL SPACE ACCESSFROM EXISTING BASEMENT
3/4" T&G PLYWD SUB FLOOROVER 12" TJI JOISTS
NEW DOOR IN ENLARGEDEXISTING WINDOW OPENING
NEW SIDING & TRIM TOMATCH EXISTING
3/4" T&G PLYWD SUB FLOOROVER 12" TJI JOISTS
NEW DOOR IN ENLARGEDEXISTING WINDOW OPENING
NEW SIDING & TRIM TOMATCH EXISTING
FINISH FASCIA/EAVETO MATCH EXISTING
10" / 12" 10" / 12"
A
A501
C
A501
A501
D
NOTE: PORTION OF EXISTINGEXTERIOR WALL TO BECOME
INTERIOR WALL TO BESTRIPPED OF SIDING TRIM
AND EXISTING WEATHERBARRIER - SHEATHING TOREMAIN - APPLY NEW 1/2"
GYPSUM WALLBOARD OVEREXISTING SHEATHING
RIDGE AND SOFFIT VENTSTO MATCH EXISTING
COORDINATE HEIGHT OFNEW TRUSS HEEL W/EXISTINGTO MAINTAIN SAME ROOF SLOPEAND TO MATCH NEW RIDGE WITHEXISTING RIDGE
EXISTINGRIDGE
FINISH ROOF TO MATCH EXISTINGOVER FELT OVER APA RATED
SHEATHING OVER PRE-ENGINEEREDROOF TRUSSES
NEW TOP OF CONCRETE SLABON GRADE IN NEW CRAWLSPACE TO MATCH TOPOF SLAB IN EXISTINGCRAWL SPACE
S101
E
S101
F
S101
G
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
ROOF BEARING118' - 2 5/8"
EXISTING ROOFSHEATHING SURFACE
EXISTING ROOFOVERHANG TO BE REMOVED
NEW DOOR AND HEADER INEXISTING OPENING - EXISTING
WINDOW OPENING HEADERTO BE REMOVED WHEN
EXPANDING OPENING FORNEW DOOR - PORTION OF
WALL BELOW EXISTINGWINDOW SILL TO BE
REMOVED
NOTE: PORTION OF EXISTINGEXTERIOR WALL TO BECOME
INTERIOR WALL TO BESTRIPPED OF SIDING TRIM
AND EXISTING WEATHERBARRIER - SHEATHING TOREMAIN - APPLY NEW 1/2"
GYPSUM WALLBOARD OVEREXISTING SHEATHING
BUILT-OVER ROOF - USEPRE-ENGINEERED TRUSSES
A501
C
D
A501
NEW TOP OF CONCRETESLAB ON GRADE IN NEWCRAWL SPACE TO MATCHTOP OF SLAB IN EXISTINGCRAWL SPACE
PROVIDE OPENING IN EXISTINGSHEATHING TO ALLOW SPACES TOCOMMUNICATE FOR VENTILATION
ACCESS OPENING IN EXISTINGFOUNDATION WALL
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
ROOF BEARING118' - 2 5/8"
8'-
5 1
/2
" +/
-8
'-1
"1
0'-
1 1
/2
"
20" w x 12" dREINFORCED CONCRETEFOOTING W/2 #5 CONTBOTTOM
4"
1'-
0"
1'-
2"
CR
AW
L S
PA
CE
DE
PT
H
+/-
9 C
OU
RS
ES
(M
AT
CH
EX
IST
ING
)1
'-0
"
8" CONCRETE BLOCKSTEM WALL W/#5@32" O.C.VERT IN GROUTED CELL
8" CONCRETE BLOCKSTEM WALL W/#5@32" O.C.VERT IN GROUTED CELL
4" DIA PERF PIPE TOSUMP (WRAP GRAVEL INGEO-TEXTILE FABRIC
3/4" ISOLATION JOINT,CONTINUOUS
4"CONC SLABOVER 6 MIL
VAPOR BARRIEROVER GRAVEL BASE
2" RIGID R10 FOAMBOARD
1/2" DIA ANCHOR BOLTS @ 48"O.C. @ NOT MORE THAN 12"FROM CORNERS NDEMBEDDED 15" MIN IN BLOCK
SPLIT FACE BLOCK TO MATCHEXISTING
2X8 ACQ SILL
LSL RIM BOARD
R-19 RIM BOARD INSULATION
11 7/8" TJI JOISTS PERFRAMING
LIGHT-FRAMED SHEAR WALLSYSTEM" 7/16" APA RATEDSHEATHING ATTACHED TOSTUDS W/8d NAILS @ 6" O.C. &AT EDGES @ 12" O.C. IN FIELD,TYPICAL
FIBER CEMENT SMOOTH LAPSIDING W/5" EXPOSURE
INFILTRATION BARRIER
1/2" GWB OVER 6MIL VAPORBARRIER
3/4" T&G APA RATED OSBSHEATHING GLUED &
FASTENED W/10d RING ORSCREW SHANK NAILS @ 6" O.C.
@ EDGES & 12" O.C. IN FIELD
LSL RIM BOARD
R-19 RIM BOARD INSULATION
11 7/8" TJI JOISTS PERFRAMING
LIGHT-FRAMED SHEAR WALLSYSTEM" 7/16" APA RATEDSHEATHING ATTACHED TOSTUDS W/8d NAILS @ 6" O.C. &AT EDGES @ 12" O.C. IN FIELD,TYPICAL
FIBER CEMENT SMOOTH LAPSIDING W/5" EXPOSURE
WEATHER RESISTIVEBARRIER
1/2" GWB OVER 6MIL VAPORBARRIER
3/4" T&G APA RATED OSBSHEATHING GLUED &
FASTENED W/10d RING ORSCREW SHANK NAILS @ 6" O.C.
@ EDGES & 12" O.C. IN FIELD
5/8" GYPSUM BOARDCEILING
5/8" GYPSUM BOARDCEILING
PRE-ENGINEERED, PRE-MANUFACTURED GABLE TRUSS
FIBER CEMENT SIDING FRIEZEBOARD TO MATCH EXISTING
FIBER CEMENT SMOOTH LAPSIDING W/5" EXPOSURE
ASPHALT SHINGLES OVER 15# ROOF FELT OVER 7/16"APA RATED SHEATHINGOVER PREMANUFACTUREDROOF TRUSSES
3/8" CEDAR PLYWD SOFFIT(OR MATCH EXISTING)
PRE-ENGINEERED, PRE-MANUFACTURED ROOF TRUSS
R30 INSULATION, MINIMUM
2X6 KICKER @ 48" O.C.
SIMPSON A35 @ EA KICKER
2X4 BLOCKING @ 32" O.C.
2X4 BLOCKING @ 32" O.C.
CONT DBL TOP PLATE
CONT DBL TOP PLATE
3"
3"
SIMPSON A35 @ EA KICKER
1ST FLOOR100' - 0"
2ND FLOOR110' - 1 5/8"
ADD ROOF BRNG118' - 2 3/4"
10
'-1
1/
2"
+/-
8'-
1"
20" w x 12" d REINFORCEDCONCRETE FOOTING W/2#5 CONT
8" CONCRETE BLOCKSTEM WALL W/#5@32" O.C.VERT IN GROUTED CELL
3" DIA PERF PIPE TOSUMP
1/2" ISOLATION JOINT,CONTINUOUS
4"CONC SLABOVER 6 MIL
VAPOR BARRIEROVER GRAVEL BASE
2" RIGID R10 FOAMBOARD
1/2" DIA ANCHOR BOLTS @48" O.C. @ NOT MORE THAN12" FROM CORNERS NDEMBEDDED 15" MIN IN BLOCK
SPLIT FACE BLOCK TO MATCHEXISTING
2X8 ACQ SILL
LSL RIM BOARD
R-19 RIM BOARD INSULATION
11 7/8" TJI JOISTSPER FRAMING
W/H2.5A EA END
10" / 12"
WINDOW TO MATCHEXISTING
WINDOW TRIMSIZE/PROFILE TO MATCHEXISTING
WINDOW PEDIMENT HEADTRIM TO MATCH EXISTING
WINDOW PEDIMENT HEADFLASHING TO MATCHEXISTING
LSL RIM BOARD
R-19 RIM BOARD INSULATION
LIGHT-FRAMED SHEAR WALLSYSTEM" 7/16" APA RATEDSHEATHING ATTACHED TOSTUDS W/8d NAILS @ 6" O.C. &AT EDGES @ 12" O.C. IN FIELD,TYPICAL
3/4" T&G APA RATED OSBSHEATHING GLUED &
FASTENED W/10d RING ORSCREW SHANK NAILS @ 6"O.C. @ EDGES & 12" O.C. IN
FIELD
WINDOW TO MATCHEXISTING
WINDOW PEDIMENT HEADTRIM TO MATCH EXISTING
WINDOW PEDIMENT HEADFLASHING TO MATCHEXISTING
3/8" CEDAR SOFFIT ORTO MATCH EXISTING
GUTTER SIZE/PROFILETO MATCH EXISTING
1X8 CEDAR FASCIA ORTO MATCH EXISTING
METAL DRIP EDGE TOMATCH EXISTING
ASPHALT SHINGLESOVER 15# ROOFINGFELT OVER APA RATED7/16" OSB OVERPREMANUFACTUREDROOF TRUSSES
COORDINATE HEIGHT OF NEWROOF TRUSS HEEL HEIGHT SO THAT
NEW TRUSS SLOPE MATCHESEXISTING AND SO THAT NEW
ROOF RIDGE IS AT OR BELOW EXISTING RIDGE HEIGHT
HE
EL
HT
TR
USS
PROVIDE INSULATIONBAFFLE
1'-8"
1'-
0"
3"
3"
11 7/8" TJI JOISTSPER FRAMING
W/H2.5A EA END
DBL TOP PLATE, CONT
DBL TOP PLATE, CONT
WEATHER RESISTIVEBARRIER
R
D
F
E
AERED
TSE
IGR
0864EB ARD.R
ATS
T
EG ORG
E O
C
CET
HI
I T
HOI0
@ 2014 BY:BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERSALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
1.
2.
3.
THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFTHE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OFBERARDI + PARTNERS, INC., ARCHITECTS AND ENGINEERS,AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION
NOTE:ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECTAND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONSSUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS.
THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS ANDTHE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESEDOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OFEACH OTHER . SEPARATION OF THE CONTRACT DOCUMENTS SHALLNOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATETHE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE.
ADDITIONALLY, SEE GENERAL INFORMATION ON "A0" SHEETS.
THE CLIENT ACKNOWLEDGES THE CONSULTANT'S(ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALLDOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OFTHE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE.THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BEMADE ANY MODIFICATION TO THE DRAWINGS ANDSPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TOWAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT)ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE ORMODIFICATION OF THE DRAWINGS AND SPECIFICATIONS.
ARCHITECT CANNOT WARRANT THE ACCURACY OF DATACONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL ORALTERED CADD DESIGN MATERIALS BY THE USER OROTHER PARTIES WITHOUT THE REVIEW AND WRITTENAPPROVAL OF THE ARCHITECT SHALL BE AT THE SOLERISK OF THE USER. FURTHERMORE, USER AGREES TODEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESSFROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES,EXPENSES, AND ATTORNEY'S FEES ARISING OUT OF THEMODIFICATION OR REUSE OF THESE MATERIALS.
THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS AREDIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOTBE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHERAPPLICABLE CODE REQUIREMENTS SHALL BE VERIFIED BY ANDARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR.ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESECODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTSSHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT.
5.
6.
4.
LIBERTYPARK
OFFICEADDITION
153 South Liberty StreetPowell, Ohio
PERMITDOCUMENTS
06/02/15
14127
10/08/12
A501
BUILDING &WALL
SECTIONS
1/4" = 1'-0"A501bldg section 'B'B
1/4" = 1'-0"A501bldg section 'A'A
3/4" = 1'-0"A501wall section - gableC
3/4" = 1'-0"A501bldg section 'B'D
Issue Description Date
Δ
@ 2014 BY:
BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERS
ALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
LIBERTY
PARK
OFFICE
ADDITION
153 South Liberty Street
Powell, Ohio
PERMIT
DOCUMENTS
06/02/15
14127
02/20/15
Issue Description Date
UP
UP
DN
@ 2014 BY:
BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERS
ALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
LIBERTY
PARK
OFFICE
ADDITION
153 South Liberty Street
Powell, Ohio
PERMIT
DOCUMENTS
06/02/15
14127
02/20/15
Issue Description Date
DN
@ 2014 BY:
BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERS
ALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
LIBERTY
PARK
OFFICE
ADDITION
153 South Liberty Street
Powell, Ohio
PERMIT
DOCUMENTS
06/02/15
14127
02/20/15
Issue Description Date
Δ
@ 2014 BY:
BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERS
ALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
LIBERTY
PARK
OFFICE
ADDITION
153 South Liberty Street
Powell, Ohio
PERMIT
DOCUMENTS
06/02/15
14127
02/20/15
Issue Description Date
UP
DN
UP
DN
@ 2014 BY:
BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERS
ALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
LIBERTY
PARK
OFFICE
ADDITION
153 South Liberty Street
Powell, Ohio
PERMIT
DOCUMENTS
06/02/15
14127
02/20/15
Issue Description Date
DN
DN
Ratings: GENERAL INFORMATION: MAIN OPTIONS: BUSS OPTIONS: BRANCH OPTIONS*
PANEL: P1 LOCATION: BASEMENT MAIN BREAKER: 200 NEUTRAL BUS: Y G = W/ GFCI PROTECTION
AMPS: 200 MOUNTING: EXISTING W/ SHUNT TRIP: N SERVICE RATED: NA = W/ ARC FAULTPROTECTION
VOLTS: 240 FED FROM: UTILITY TRANSFORMER MAIN LUGS ONLY: N GRD. BUS: Y R = W/ RELAY CONTROL
PHASE: 1 SHORT CIRCUIT: EXISTING SUB-FEED LUGS: N ISO. GRD. BUS: N L = W/ LOCK ON DEVICE
WIRE: 3 FEED THRU LUGS: N
VA LOAD WIRE GRD CB/P * CKT Ø CKT * CB/P GRD WIRE LOAD VA
0 A/C #1 40/2 E 1 A 2 E 40/2 A/C #2 0
0 " " 40/2 E 3 B 4 E 40/2 " " 0
0 2ND FLR RECEPT, OPEN OFFICE, BATH 20/1 E 5 A 6 E 20/1 2ND FLR LIGHTS,ATTIC LIGHT 0
0 RM 204 WATER TANK 20/1 E 7 B 8 E 20/1 MAIN FLR LIGHTING 0
0 RECEPTION, BATH GRF, EXTERIOR GRF 20/1 E 9 A 10 E 20/1 RM 205 N & E RECEPT 0
0 BASEMENT, GARBAGE DISP 20/1 E 11 B 12 E 20/1 RM 205 EAST WALL QUAD 0
0 BSMNT DISHWASHER 20/1 E 13 A 14 E 20/1 2ND FLR LIGHTING 0
0 EXIT/EM LIGHTS 20/1 E 15 B 16 E 20/1 RM 205 WEST WALL QUAD 0
0 LOUNGE,FRIDGE/CAB RECEPT 20/1 E 17 A 18 E 20/1 RM 205 SOUTH WALL QUAD 0
0 WORK RM OUTLETS & SOUTH WALL 20/1 E 19 B 20 E 20/1 MAIN FLR LIGHTING 0
0 BSMNT FRIDGE 20/1 E 21 A 22 E 20/1 RM 204 N &E WALL RECEPT 0
0 WORK RM RECEPT& E WALL 20/1 E 23 B 24 E 20/1 RM 206 WEST & EAST WALL 0
0 BATH GFI 2ND FLR 20/1 E 25 A 26 E 20/1 RM 106 & CORRIDOR RECEPT 0
0 BASEMENT KITCHEN GFI 20/1 E 27 B 28 E 20/1 OFFICE RM 107& GENERAL RECEPT 0
0 BASEMENT LIGHTS 20/1 E 29 A 30 E 20/1 LOUNGE & COUNTER RECEPTACLES 0
0 ATTIC FURNACE 20/1 E 31 B 32 E 20/1 MAIN FLOOR LIGHTS 0
0 RM'S 204,206 & QUAD GEN RECEPT 20/1 E 33 A 34 E 20/1 MAIN FLOOR& EXTERIOR REAR LIGHTS 0
0 BASEMENT FURNACE 20/1 E 35 B 36 E 20/1 MAIN FLR LIGHTING 0
0 COMUTER GFI 20/1 E 37 A 38 E 20/1 RM 104 & GEN RECEPTACLES 0
0 SUMP PUMP 20/1 E 39 B 40 E 20/1 LOUNGE GENERAL RECEPTACLES 0
1080 RECEPTACLES NEW ADDITION 12 12 20/1 41 A 42 20/1 12 12 RECEPTACLES NEW ADDITION 1080
CONNECTED(VA) DEMAND FACTOR
DEMAND(VA) PHASE A CONNECTED LOAD (KVA)= 0.00
LIGHTING 0 125% 0 PHASE B CONNECTED LOAD (KVA)= 2.16
RECEPTACLES 2,160 100% FOR < 10KVA50% REMAINING VA
2,160TOTAL CONNECTED LOAD (KVA)= 2.16
ELECTRIC SPACE HEAT 0 0% 0
COOLING 0 100% 0 TOTAL CONNECTED LOAD (AMPS)= 9.00
MOTORS 0 100% + 25% LARGEST 0
MISCELLANEOUS 0 100% 0
PANEL TOTAL (VA) 2,160 2,160
CURRENT @ 240V 1Ø (AMPS) 9.0 9.0
@ 2014 BY:
BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERS
ALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
LIBERTY
PARK
OFFICE
ADDITION
153 South Liberty Street
Powell, Ohio
PERMIT
DOCUMENTS
06/02/15
14127
02/20/15
Issue Description Date
@ 2014 BY:
BERARDI + PARTNERS, INC.
ARCHITECTS AND ENGINEERS
ALL RIGHTS RESERVED
PROJECT DATE:
PROJECT #:
SHEET DATE:
LIBERTY
PARK
OFFICE
ADDITION
153 South Liberty Street
Powell, Ohio
PERMIT
DOCUMENTS
06/02/15
14127
02/20/15
Issue Description Date