Download - Catalogo Completo Da Apollo 2011
-
7/29/2019 Catalogo Completo Da Apollo 2011
1/144
Fire detectionequipment
Product Ca
t al ogue2011
-
7/29/2019 Catalogo Completo Da Apollo 2011
2/144
Apollo Fire Detectors Ltd. has specialised in the design and manuacture
o high quality ire detection products since 1980. In that time, the
company has broadened its capability rom a straightorward ocus on
conventional ire detectors to include the manuacture o sophisticated
analogue addressable detectors and interaces or monitoring and
controlling equipment in ire protection systems.
Apollo applies the most modern production techniques and has invested
in sophisticated manuacturing equipment to ensure consistent high
quality products and ast response to customer requirements. Through
planned expansion, Apollo has reached a leading position in the marketor proessional ire detectors and exports over hal o its production
to countries around the world. In 2007, Apollo unveiled a new brand
identity, urther cementing its position as a world class ire solutions
provider.
Based in Havant, Hampshire, Apollo operates rom one site. All
departments - Research and Development, Sales and Marketing,
Manuacturing and Finance are located here.
Apollo is a Halma company. Halma is a holding company or over 40
subsidiaries worldwide, all engaged in specialist engineering activities.
* The Product Lietime Guarantee is subject to terms and conditions. For urther inormation,please reer to our current General Conditions o Sale.
Why Choose Apollo? Largest independent smoke detector
manuacturer in the world
Certified to all key international approvals
Product Lifetime Guarantee*
The best people work for Apollo
Trustworthy, integrity & supportive
Localised customer service worldwide
Ex stock delivery
100% reliability, 100% tested
Open, digital protocol
Forwards and backwards product compatibility
World Class Fire Solutions
Apollo - The Partner o Choice
-
7/29/2019 Catalogo Completo Da Apollo 2011
3/144
Inormation in this catalogue is given in good aith, but Apollo Fire Detectors cannotbe held responsible or any omissions or errors. The company reserves the right tochange speciications o products at any time without prior notice.
Contents
10Analogue AddessableDiscovery, XP95
41Wireless TechnologyXPander
46Flush Mounted TechnologyPlateau
84Manual Call Points
107ULXP95A, Series 65A, Discovery UL
123Test Equipment and Maintenance
25ConventionalOrbis, Series 65
59Audio Visual SignallingSounders, Beacons, Sounder Beacons,Sounder Beacon Bases
91MarineDiscovery, Orbis
49Specialist DetectorsFlame, Beam & Duct Detectors
87Mounting Accessories
35Two-Wire TechnologyAlarmSense
77InteracesIsolated, Mini, DIN-Rail
100Intrinsically SaeXP95, Orbis
How do Detectors Work? ..........4
New Products ............................6
Additional Services ....................8
Approvals ..............................126
Index .....................................133
By Appointment toHer Majesty The Queen
Manuacturers o Fire Detection& Alarm Products
Apollo Fire Detectors LimitedHampshire
-
7/29/2019 Catalogo Completo Da Apollo 2011
4/144
How Do They Work?
4
How do Detectors Work?
Optical (photo-electric) smoke detector
Optical smoke detectors incorporate a pulsing infra-red LED
located in a chamber within the housing o the detector. The
chamber is designed to exclude light rom any external source.
At an angle to the LED is a photo-diode which normally does
not register the column of light emitted by the LED. In the
event o smoke rom a ire entering the chamber, the light
pulse from the LED will be scattered and hence registered bythe photo-diode. I the photo-diode sees smoke on the two
ollowing pulses, the detector changes into alarm state and the
indicator LED lights up. The detector housing is identical to
that of the ionisation detector but has an indicator LED which
is clear in quiescent state but produces red light in alarm.
Optical smoke detectors respond particularly well to
slow-burning (smouldering) fires. They are widely used
for life protection.
Multisensor detector
A multisensor detector is basically an optical smoke detector -
so it will respond well to smouldering ires. The addition o a
heat sensing element allows the multisensor to give a response
to ast burning (laming) ires which is comparable to that o
an ionisation detector.
Multisensor detectors are general purpose detectors
which respond well to a wide range of fires.
Ionisation smoke detector
The sensing part o the detector consists o two chambers - anopen, outer chamber and a semi-sealed reerence chamber
within. Mounted in the reerence chamber is a low activity
radioactive oil o Americium 241 which enables current to
low between the inner and outer chambers when the detector
is powered up. As smoke enters the detector, particles
become attached to the ions, causing a reduction in current
low in the outer chamber and hence an increase in voltage
measured at the junction between the two chambers. The
voltage increase is monitored by the electronic circuitry which
triggers the detector into the alarm state at a preset threshold.
An externally visible red LED lights up when the detector
changes to alarm state.Ionisation smoke detectors are good specialist detectors
which respond well to fast-burning (flaming) fires and are
now used to overcome specialist problems.
Integrating ionisation smoke detector
This type o detector works on the same principles as the
ionisation smoke detector, but has modiied signal processing
circuitry which allows an alarm threshold to be present or up
to 20 seconds without initiating an alarm.
This type o detector is suitable or use in areas where
transient high levels o smoke may be expected.
Photo-diode
Infra-red LED
Thermistorexposed to air
Multisensor detector
+
Apollo Fire Detectors Limited 2001/JDR
+
+
+
++
+ +
+
+
+
++
+ +
In clean air With smoke0 volts
Sensing chamber
Sensingelectrodes
Referencechamber
Radioactivefoil
10 volts onfoil holder
Negatively charged ion
Positively charged ion
Smoke particle
+
Ionisation smoke chamber
Apollo Fire Detectors Limited 1997/RHD/JDR
In clean air With smoke
Photo-diode
Infra-red LED
Optical smoke chamber
Light beamDiffused light beam
Smoke particle
Apollo Fire Detectors 1997/RHD
-
7/29/2019 Catalogo Completo Da Apollo 2011
5/144
How Do They Work?
5
Integrating effect in analogue addressable systems
In XP95 systems, the integrating eect can be mimicked in
both ionisation and optical smoke detectors by adjusting the
control equipment sotware to cause an appropriate delay.
Discovery smoke detectors should be set to Mode Two or
Mode Four to achieve this eect.
Carbon Monoxide (CO) detector
Carbon Monoxide (CO) is a poisonous gas produced by
combustion and a CO fire detector is used to indicate theoutbreak of a fire by sensing the level of CO in the air. The
detector has an electrochemical cell which senses CO, but
not smoke or other combustion products. The cells do not
require much power, so the detector can be made electrically
compatible with ordinary smoke and heat detectors. Apollo
manufacturers a CO detector as part of the Discovery range.
CO detectors are particularly good at detecting deep-
seated, smouldering fires.
Heat detector
Most conventional heat detectors operate by using a matchedpair of thermistors to sense heat. One thermistor is exposed
to the ambient temperature, the other is sealed. In normal
conditions the two thermistors register similar temperatures,
but, on the development o a ire, the temperature recorded
by the exposed thermistor will increase rapidly, resulting in an
imbalance o the thermistors, causing the detector to change
into alarm state. Rate-o-rise detectors are designed to detect
a ire as the temperature increases, but they also have a ixed
upper limit at which the detector will go into alarm i the
rate o temperature increase has been too slow to trigger the
detector earlier.
The Series 65 and AlarmSense CS (static response) heat
detectors have only one thermistor. They change to the alarm
state at a preset temperature.
Externally, the heat detectors are distinguishable from the
smoke detectors by having wide openings to the surrounding
atmosphere to allow good movement o air around the
external thermistor.
A heat detector may be more appropriate than a smoke
detector where the environment is dirty or smoky under
normal conditions. It must be recognised, however, that
any heat detector will respond only when a fire is wellestablished and generating a high heat output.
Intelligent reflective beam detector
Intelligent relective beam detectors comprise a single unit
which houses a transmitter, a receiver and the control
electronics. When a ire develops, smoke particles obstruct
the beam o light and, once a pre-set threshold has been
exceeded, the detector will go into alarm.
Beam detectors are designed to protect large
open spaces such as atria, museums, churches and
warehouses.
Flame detector
A lame detector is designed to detect either ultraviolet (UV)
or inra-red (IR) radiation emitted by a ire. The XP95 Dual IR
lame detector is sensitive to low-requency, lickering inra-red
radiation. This means that the detector can operate even i the
lens is contaminated by a layer o oil, dust, water vapour or ice.
Flame detectors are effective in protecting areas where
flaming fires may be expected.
Normal Conditions Rate-of-rise response Fixed temperature response
Thermistorpartiallysealed fromsurroundingair
Thermistorexposed to air
Fire detected on fastincrease of ambient
temperature
Fire detected onslowincrease of ambient
temperature
Note: Analogue addressable heat detectors use only a single thermistor
Dual thermistor heat detection
Apollo Fire Detectors Limited 1997/RHD/JDR
-
7/29/2019 Catalogo Completo Da Apollo 2011
6/144
New Products
6
Apollo prides itself on being a leader
in product innovation. Providing fire
solutions that meet the demands of our
customers is the main pillar of Apollos
product development programme. We are
constantly working with our customers todevelop new products to meet their needs.
A further commitment to Apollos customer
focus has seen the Marketing team be
strengthened by the introduction of three
new product management roles. These
dedicated personnel will be responsible for
the future direction of the portfolio as well
as the internal management of the ranges.
A prime responsibility of the new roles is
continuation of customer focused product
development within Apollo and continuing
to be the Partner of Choice.
If you have any comments or suggestions
on any new or existing products, feel free
to email [email protected]
NewProducts
-
7/29/2019 Catalogo Completo Da Apollo 2011
7/1447
New Products
7
New products or 2011Plateau
Plateau is a major advance in ire detector
design, providing eective detection withminimum intrusion. The Plateau smoke
detector, when installed, is a very slim
device. It is ideal or use in installations
where it is impractical or undesirable to
use a standard smoke detector. For more
inormation, please see page 47.
XPander updates
XPander, Apollos range o wireless
ire detectors, has been upgraded with
new sotware or its Loop Interace. This
increases the number o devices each
interace can support rom 15 up to 31. In
addition, an Input/Output unit has been
added to the range which can be used
or controlling ire doors, ire dampers,
smoke vents and other ire engineering
applications. For more inormation, please
see page 41.
AlarmSense AV
The two-wire AlarmSense range has been
enhanced with the introduction o threeopen-area signalling devices. New or
2011 are the Open-Area Sounder, Open-
Area Beacon and Open-Area Sounder
Beacon. Originally designed to meet
the requirements o Houses in Multiple
Occupation (HMOs), AlarmSense is
suitable or use in small to medium
applications. AlarmSense devices are
designed to be connected to the same pair
o supply wires, which reduces cabling
costs and installation time. For more
inormation, please see page 39.
Base mounted flame detectors Marine
and Standard
The Apollo range o base mounted lame
detectors have been designed to provide
rapid detection o all types o lames. There
is a choice o detection methods to guard
against unwanted alse alarms. For more
inormation, please see page 49.
Discovery Open-Area Sounder Beacon
The Discovery Open-Area Sounder Beacon
makes ull use o the Discovery protocol andhas been designed or use in indoor open
areas and outdoors. Tones can be used or
other purposes in addition to the warning o
ire, ideal or schools and there is a sot start
option, ideal or hospitals and nursing homes.
For more inormation, please see page 66.
Discovery Marine Sounder Beacon Base
Apollos Discovery Marine Sounder Beacon
Base has been approved or use in marine
applications. The device makes ull use o the
Discovery protocol and when the ire system
is being commissioned a magnetic wand
can be used to adjust and test each sounder
locally. For more inormation, please see
page 95.
Marine approved DIN-rails
New or 2011 are a range o our marine
approved DIN-rail interaces Marine DIN-
rail 8 Ampere Sounder Controller, Marine
DIN-rail Dual Isolator, Marine DIN-rail
Switch Monitor Plus and Marine DIN-railZone Monitor. The interaces are compatible
with Apollo XP95 and Discovery protocols
and have ABS and MED approval. For more
inormation, please see page 95.
UL approved AV products
Apollo now oers a range o UL listed loop
powered Audio Visual signaling devices.
Open Area and Base version products are
oered in both the XP95 and Discovery
ranges. These products do not require a
separate power source to unction and
thereore provide a cost eective solution
with added eatures and intelligence or audio
visual notiication installations. The Discovery
devices incorporate extra eatures, such as
panel controlled volume and tone settings.
The Sounder Beacon bases are available in
two types, with yellow or red flashing LEDs.
Coming soon Voice Sounder
Discovery CO/Heat Multisensor detector UL listed pull station
Marine Isolating Base
-
7/29/2019 Catalogo Completo Da Apollo 2011
8/144
Additional Services
8
Servicing and Disposal
Apollo oers a Service acility or Apollo detectors and ancillary products,
such as interaces and manual call points. This means that older models
o Apollo detectors can be serviced (subject to them being within their
recommended working lie).
The ollowing services are oered:
Detectors can be cleaned and recalibrated so that they work within the
same limits as newly manuactured detectors.
Manual call points and XP95 interfaces can be cleaned and tested to
ensure that they are still unctioning within manuacturing limits.
Equipment which is found to be beyond economical repair (BER) or is
older than its recommended working lie can be disposed o - a small
charge is made or this service to cover the cost o investigation and
disposal.
Loop Calculator
The Apollo Loop Calculator is a ree computer programme
used to establish the viability o a design. It enables engineers to
calculate the total loop loading in a proposed Discovery or XP95
ire detection system by inputting relevant variables, or example
control equipment, loop devices and cable length and type. Parameters
are included or Apollo protocol compatible panels. Please see the Apollo
website or more details
www.apollo-fire.co.uk/loop-calc
Product Lifetime Guarantee
We guarantee all our products in accordance with our
recommended working lie o the product, which or detectors
we would recommend 10 years (for CO detectors, 5 years),
giving you the assurance o the quality and reliability o both our
products and our service. The Product Lietime Guarantee is subject to terms
and conditions. For urther inormation, please reer to our current General
Conditions o Sale.
Additional
Services
-
7/29/2019 Catalogo Completo Da Apollo 2011
9/144
Additional Services
9
SimSystem
SimSystem (29600-164) is a tool or simulating loops o detectors and interaces
in order to demonstrate a system and prove the design without having to
connect actual products to a control panel. SimSystem consists o a sotware
programme which eatures an intuitive graphical display and an interace which
runs up to our loops. A maximum o two interaces can be connected, thus
allowing a system o up to eight loops to be simulated.
Training
Apollo oers a series o ree one-day training courses or its customers. The
courses cover the ollowing modules:
Module 1: Detection Principles & Device Selection
Module 1.1: Carbon Monoxide Fire Detection
Module 2: Conventional Detector Operation
Module 2.1: AlarmSense
Module 2.2: Orbis
Module 3: Analogue Addressable Principles
Module 3.1: XP95
Module 3.2: Discovery
Module 3.3: XPlorer
Module 3.4: AV Alarm Devices
Module 3.5: XPander
Module 4: Intrinsically Safe Equipment
Module 5: Service, Test & Maintenance
In addition to the standard training courses, Apollo can oer tailor-made
courses i required. The majority o courses are held at Apollos head oice, but
on-site training is also available.
You can ind out more about Apollos training days and book your place byvisiting www.apollo-fire.co.uk/training
CPD Seminars
Apollo now oers training seminars that will count towards your Continuing
Proessional Development. These ree sessions on ire industry-related topics allow
you to stay up to date.
False Alarm Reduction in Automatic Fire Detection Systems - the
Manufacturers Contribution
Independent Certification /EU Construction Products Directive for Fire Products
To ind out more email [email protected] or visit www.apollo-ire.co.uk
-
7/29/2019 Catalogo Completo Da Apollo 2011
10/14410
Apollo oers two ranges o analogue addressable
systems - Discovery and XP95. Discovery is
Apollos high-speciication range and oers the
ollowing advantages over XP95:
Five operating modes, each EN54 approved
to provide the widest possible ire detection
solution
Automatic drit compensation where the
detector automatically compensates or the
build up o contamination, maintaining a
stable alarm threshold
Access to a more advanced range o eatures
in Discovery audio visual equipment
There are two types o analogue addressable
system those with distributed intelligence andthose with centralised intelligence.
In systems with distributed intelligence the
detectors incorporate processors which can
determine whether alarm levels o smoke or heat
exist and can initiate action accordingly.
Detectors in systems with centralised intelligence
monitor the air around them or smoke or heat
and transmit the data to the control panel on
interrogation. The processor in the panel compares
the values with stored values and determines
whether a pre-alarm or alarm should be signalled.
The advantages o distributed intelligence are local
adaptation to environment and reduction o traic
on the supply and data wires. The advantage o
centralised intelligence is the ability to upgrade a
system very quickly and easily by upgrading the
control panel.
Analogue
AddressableFire Detection
-
7/29/2019 Catalogo Completo Da Apollo 2011
11/144
Analogue Addressable Fire Detection : Discovery
11
Discovery is a range o high-speciication, analogue
addressable ire detectors. Discovery detectors oer reliable
detection and alse alarm management by a combination
of EN54 approved operating modes and sophisticated
algorithms. Discovery has a distributed intelligence system
where decisions are made in the detector head as well as atthe control panel. Drit compensation is also incorporated
into the detector, allowing it to adapt to dirty or dusty
environments, which reduces alse alarms.
Each detector in the Discovery range can operate in one of five response modes,
which can be selected rom the control panel or hand held programmer. The
response characteristics have been careully set so that the detectors comply with the
requirements of the relevant part of EN54 in all response modes. Mode One will give
a higher sensitivity to ire than Mode Five.
Designed or use in medium to large applications with speciic system requirements,
Discovery gives you total reassurance in installations where adaptability to changing
conditions and protection against unwanted alarms is paramount.
Discoveryanalogue addressable re detection
Key features of Discovery include:
Five EN54 approved operating modes
Automatic drift compensation to ensureconstant sensitivity
Advanced feature for audio visualdevices
Rejection of transient signals
Flashing LED option
Four bytes of non-volatile memory foruser data
Alarm flag for fast alarm reporting
Conventional alarm facility during controlpanel processor fault
360 visibility in alarm
Compatible with XP95 systems
Insect Resistant
For UL listed Discovery devices
please turn to page 108
-
7/29/2019 Catalogo Completo Da Apollo 2011
12/144
Analogue Addressable Fire Detection : Discovery
12
Discovery Optical Smoke Detector
The Discovery Optical Smoke Detector worksusing the light scatter principle and is ideal or applications
where slow-burning or smouldering ires are likely.
Responds well to slow-burning,smouldering ires
Well suited or bedrooms and escape routes
Unaffected by wind or atmospheric
pressure Remote test feature58000-600 Discovery Optical Smoke Detector
Discovery Multisensor Detector
The Discovery Multisensor Detector comprises opticalsmoke and thermistor temperature sensors who give both
a combined signal as well as a separate heat signal orimproved alse alarm management.
Ideal for a wide range of applications
Enhanced false alarm management
Well suited for environments such ashotel bedrooms
Unaffected by wind or atmosphericpressure
Well suited for sensitive environments Heat only, optical only options
Remote test feature
58000-700 Discovery Multisensor Detector
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Discovery Carbon Monoxide Detector
The Discovery Carbon Monoxide (CO) Detector is good at
detecting deep-seated fires. Please note that CO detectorsdo not detect smoke particles or heat and are not universal
replacements or smoke detectors.
Enhanced detection capability
Ideal for smouldering fires
Less susceptible to false alarms causedby steam than smoke alarms
Five response modes
Remote test feature58000-300 Discovery Carbon Monoxide Detector
Discovery Ionisation Smoke Detector
The Discovery Ionisation Smoke Detector uses
a low activity radioactive oil to detect ires by irradiatingthe air in the smoke chambers and causing a current low.
I smoke enters the chamber, the current low is reduced
leading to an alarm.
Responds well to ast-burning, lamingires
Designed to operate in a variety ofenvironments
Remote test feature
58000-500 Discovery Ionisation Smoke Detector
-
7/29/2019 Catalogo Completo Da Apollo 2011
13/144
Analogue Addressable Fire Detection : Discovery
13
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Discovery Heat Detector
The Discovery Heat Detector, distinguishable by the lowairlow resistant case, uses a single thermistor to sense the
air temperature around the detector.
Ideal in environments that are dirty orsmoky under normal conditions
Well suited for warehouses, loadingbays and car parks
Unaffected by wind or atmosphericpressure
Remote test feature
58000-400 Discovery Heat Detector
Intelligent Deep Base
The Intelligent Deep Base is a mounting base or Discoveryproducts which has an increased depth which allows or
cables to be inserted into the side o the product.
Enables surface wiring
45681-209 Intelligent Deep Base
Intelligent Mounting Base
All detectors in the Discovery range it the IntelligentMounting Base. The Mounting Base is a low insertion orce
base with stainless steel contacts or the detector terminals.XPERT cards are supplied with all bases.
XPERT addressing
One way fit
Locking feature to preventunauthorised removal
45681-210 Intelligent Mounting Base
Isolating BaseThe Isolating Base senses and detects short-circuit aults onDiscovery loops and spurs.
The equivalent of up to 20 smokedetectors may be installed betweenisolating bases
High brightness LED45681-284 Isolating Base
Isolator
The Isolator is placed at intervals on the loop and ensures
that, in the case o a short-circuit, only the section betweenthe isolators will be aected. When the short-circuit is
removed, the isolators automatically restore power and datato the isolated section.
Detects wiring short circuits
Minimises disruption from short-circuits
Automatic de-isolation on short-circuit removal
The equivalent of up to 20 smokedetectors may be installed betweenisolators
55000-720 Isolator
*Uses 45681-211 Isolator Base
-
7/29/2019 Catalogo Completo Da Apollo 2011
14/144
Analogue Addressable Fire Detection : Discovery
14
Product Name Part Number Page No.
MOUNTING ACCESSORIES 87
Backplate 45681-233 88
Base Cover 45681-380 88
Conduit Box 45681-204 83
Sounder Ceiling Plate 45681-311 88
Module Base 38531-822 88
Deckhead Mounting Box 45681-217 89
Deckhead Mounting Box Kit 45681-218 89
Metal Deckhead Mounting Box PG16 29600-131 89
Ancillary devices available for the Discovery range:
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Isolator Base
The Isolator Base is unique and designed to only accept theIsolator 55000-720.
Only accepts 55000-720 isolators
45681-211 Isolator Base
Intelligent Heater Base
The Intelligent Heater Base is designed to be used in coldclimates where environmental conditions could result in
either icing or condensation aecting the operation odetectors. It is recommended that the heater base be used
in conjunction with either a Waterproo Base Cover orDeckhead Mounting Box to minimise moisture ingress.
Raises the ambient temperature of adetector chamber by approximately10C
Limits the risks or potential for losseso unctionality o detectors installedin these conditions.
45681-219 Intelligent Heater Base45681-519 Waterproo Base Cover
45681-217 Deckhead Mounting Box
Intelligent Low Power Relay Base
The Low Power Relay Base incorporates a low power relay
to control ield equipment. Gives a set of voltage free contacts
controlled by the remote output o adetector
Draws negligible current
Capable of switching up to 30V at 1A45681-242 Intelligent Low Power Relay Base
MiniDisc Remote Indicator
The MiniDisc Remote Indicator is a light-weight, compactred LED indicator for use in fire protection systems.
Can be used across the entire Apollorange
Small and discrete
Anti-tamper screw to protect againstunauthorised removal
53832-070 MiniDisc Remote Indicator
-
7/29/2019 Catalogo Completo Da Apollo 2011
15/144
Analogue Addressable Fire Detection : Discovery
15
Product Name Part Number Page No.
Metal Deckhead Mounting Box M20 29600-139 89
Deckhead Adaptor PG16-M20 27249-005 89
Detector Ceiling Tile Mounting Box 45681-309 89
Sounder Ceiling Tile Mounting Box 45681-310 89Beacon Enclosure 29600-318 89
DIN-Rail Interface Enclosure (4 units) 29600-239 89
DIN-Rail Interface Enclosure (10 units) 29600-240 89
1.5mm Hexagonal Driver 29600-095 90
MANUAL CALL POINTS 84
Discovery Manual Call Point Red (Surace) 58100-910 85
Discovery Manual Call Point with Isolator Red (Surace) 58100-908 85
Discovery Manual Call Point White 58100-926 85
Discovery Manual Call Point Yellow 58100-927 85
Discovery Manual Call Point Blue 58100-928 85
Discovery Manual Call Point Green 58100-929 85
Transparent Hinged Cover 26729-152 86
Weatherproo Manual Call Point Red 58100-950 85
Weatherproo Manual Call Point Red with Isolator 58100-951 85
Waterproo Manual Call Point Yellow with Isolator 58100-953 85
STANDARD INTERFACES 78
Input/Output Unit 55000-847 79
Three Channel Input/Output Unit 55000-588 79
Output Unit 55000-849 79
Sounder Control Unit 55000-852 79
Switch Monitor 55000-843 79
Switch Monitor Plus 55000-841 80
Zone Monitor 55000-845 80
MINI INTERFACES 83
Mini Switch Monitor 55000-760 83
DIN-RAIL INTERFACES 81
DIN-Rail Sounder Controller (5 Amperes) 55000-182 82
DIN-Rail Input/Output Unit 55000-803 82
DIN-Rail Output Unit 55000-804 82
DIN-Rail Switch Monitor 55000-822 82
DIN-Rail Switch Monitor Plus 55000-821 83
DIN-Rail Zone Monitor with Isolator 55000-812 83
DIN-Rail Dual Isolator 55000-802 83
DIN-Rail Mains I/O 55000-797 82
AUDIO VISUAL SIGNALLING 59
Discovery Sounder Beacon Base 45681-393 74
Intelligent Open-Area Sounder Red 55000-001 61
Intelligent Open-Area Sounder White 55000-002 61
100dB (A) Open-Area Sounder Red 55000-278 61
100dB (A) Open-Area Sounder White 55000-279 61
100dB (A) Open-Area Weatherproof Sounder Red 55000-274 61
100dB (A) Open-Area Weatherproof Sounder White 55000-275 61
Integrated Base Sounder 45681-278 70Integrated Base Sounder with Isolator 45681-277 69
-
7/29/2019 Catalogo Completo Da Apollo 2011
16/14416
Analogue Addressable Fire Detection : Discovery
16
Product Name Part Number Page No.
Integrated Base Sounder Slow Whoop 45681-291 70
Integrated Base Sounder Slow Whoop with Isolator 45681-290 69
Integrated Base Sounder DIN-Tone with Isolator 45681-300 69
White Cap 45681-292 69Red Cap 45681-293 69
Ancillary Base Sounder 45681-276 69
Intelligent Open-Area Beacon Red Lens 55000-009 64
Intelligent Open-Area Beacon Clear Lens 55000-010 64
Loop-Powered Beacon Red 55000-877 64
Loop-Powered Beacon Amber 55000-879 64
Loop-Powered Beacon Clear Lens/Red Flash 55000-878 64
Beacon Enclosure 29600-318 89
Loop-Powered Beacon Base with Isolator 45681-333 72
Loop-Powered Beacon Base with Standard Flash 45681-335 72
Loop-Powered Beacon Base with Australian Flash 45681-337 72
Intelligent Open-Area Sounder Beacon Red Lens 55000-005 66
Intelligent Open-Area Sounder Beacon Clear Lens 55000-006 66
Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-293 66
Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-294 66
Multi-Tone Open-Area Sounder Beacon Red 55000-291 67
Multi-Tone Open-Area Sounder Beacon White 55000-292 67
Weatherproof Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-298 66
Weatherproof Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-299 66
Weatherproof Multi-Tone Open-Area Sounder Beacon Red 55000-296 67
Weatherproof Multi-Tone Open-Area Sounder Beacon White 55000-297 67
Sounder Beacon Base with Isolator 45681-330 74
Sounder Beacon Base 45681-331 74
Sounder Beacon Base with Australian Tone 45681-336 74
Sounder Beacon Base with Isolator DIN-Tone 45681-334 74
Sounder Beacon Base with NZ Tone 45681-338 74
Sounder Beacon Base Slow Whoop with Isolator 45681-332 74
Magnetic Wand 29650-001 76
Discovery Sounder Beacon (open areas) 58000-005 66
Discovery Sounder Beacon (open areas) 58000-007 66
-
7/29/2019 Catalogo Completo Da Apollo 2011
17/14417
Analogue Addressable Fire Detection : XP95
17
The XP95 range o analogue addressable ire detectors is
advanced in design, improved in perormance and has
unique eatures that beneit the installer and end user.
The range eatures smoke detectors (optical and ionisation), standard and high
temperature heat detectors and a multisensor. Beam detectors, lame detectors,
manual call points, audio visual signalling devices, interace units and isolators
complete the range. XP95 has a central intelligence system where all the decisions
are made by the control panel.
Apollo has always used an open, digital protocol since 1986 and has ensured
backward compatibility when developing new products. An open protocol allows
reedom o choice or the ire system speciier, installer and end user. A system using a
digital protocol is also much less susceptible to corruption than an analogue protocol
and is thereore oten preerred in a system which is lie critical. XP95 is suitable or
medium to large applications with simple installation requirements.
XP95analogue addressable ire detection
Key features of XP95 include:
Alarm Flag for fast alarm reporting
Alarm Address for fast location of
alarm
XPERT card addressing
Electronics-free base
Easy installation
Elegant design
Insect Resistant
-
7/29/2019 Catalogo Completo Da Apollo 2011
18/144
Analogue Addressable Fire Detection : XP95
18
XP95 Ionisation Smoke Detector
The XP95 Ionisation Smoke Detector uses a low activityradioactive oil to detect ires by irradiating the air in the
smoke chambers and causing a current low. I smokeenters the chamber, the current low is reduced leading to
an alarm.
Responds well to fast-burning, flamingires
Designed to operate in a variety ofenvironments
Minimal effects from temperature,humidity, atmospheric pressure
Well protected againstelectromagnetic intererence over awide requency range
55000-500 XP95 Ionisation Smoke Detector
55000-560 XP95 Ionisation Smoke Detector (Black)55000-520 XP95 Ionisation Smoke Detector (VdS)
XP95 Heat Detector
The XP95 Heat Detector monitors temperature by using
a single thermistor which provides a count outputproportional to the external air temperature. The XP95
range eatures two heat detectors, standard and hightemperature. The standard heat detector is classiied asan A2S device and will report an alarm at 55C. The high
temperature detector, classiied as a CS device, will reportan alarm at 90C.
Ideal in environments that are dirty orsmoky under normal conditions
Well suited for warehouses, loadingbays and car parks
Unaffected by wind or atmosphericpressure
55000-400 XP95 Heat Detector A2S55000-420 XP95 Heat Detector A2S (VdS)
55000-401 XP95 Heat Detector CS
XP95 Optical Smoke Detector
The XP95 Optical Smoke Detector works using the lightscatter principle and is ideal or applications where slow-
burning or smouldering ires are likely.
Responds well to slow-burning,smouldering ires
Well suited for bedrooms and escaperoutes
Unaffected by wind or atmosphericpressure55000-600 XP95 Optical Smoke Detector55000-660 XP95 Optical Smoke Detector (Black)
55000-620 XP95 Optical Smoke Detector (VdS)
XP95 Multisensor Detector
The XP95 Multisensor Detector contains an optical smoke
sensor and a thermistor temperature sensor whose outputsare combined to give the inal analogue value.
Sensitive to a wide range of fires
Well suited for environments such ashotel bedrooms
Unaffected by wind or atmosphericpressure55000-885 XP95 Multisensor Detector
Intelligent Mounting Base
All detectors in the XP95 range it the Intelligent MountingBase. The Mounting Base is a low insertion orce base with
stainless steel contacts for the detector terminals. XPERTcards are supplied with all bases.
XPERT addressing
One way fit of detector
Locking eature to preventunauthorised removal
45681-210 Intelligent Mounting Base
45681-361 Intelligent Mounting Base (Black)
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
-
7/29/2019 Catalogo Completo Da Apollo 2011
19/144
Analogue Addressable Fire Detection : XP95
19
Isolating Base
The new style Isolating Base senses and detects short-circuitaults on XP95 loops and spurs.
The equivalent of up to 20 smokedetectors may be installed betweenisolating bases
High brightness LED45681-284 Isolating Base
Isolator
The Isolator is placed at intervals on the loop and ensures
that, in the case o a short-circuit, only the section betweenthe isolators will be aected. When the short-circuit isremoved, the isolators automatically restore power and data
to the isolated section.
Detects wiring short circuits usingpatented technology
Minimises disruption from short-circuits
Automatic de-isolation on short-circuit removal
The equivalent of up to 20 smokedetectors may be installed betweenisolators
55000-720 Isolator*Uses 45681-211 Isolator Base
Isolator Base
The Isolator Base is unique and designed to only accept the
Isolator 55000-720. Only accepts isolators
45681-211 Isolator Base
Intelligent Low Power Relay Base
The Low Power Relay Base incorporates a low power relayto control ield equipment.
Gives a set of voltage free contactscontrolled by the remote output o adetector
Draws negligible current
Capable of switching up to 30V at 1A45681-242 Intelligent Low Power Relay Base
Intelligent Deep BaseThe Intelligent Deep Base is a mounting base or XP95products which has an increased depth which allows orcables to be inserted into the side o the product.
Enables surface wiring
45681-209 Intelligent Deep Base
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
-
7/29/2019 Catalogo Completo Da Apollo 2011
20/144
Analogue Addressable Fire Detection : XP95
20
Ancillary devices available for the XP95 range:
Product Name Part Number Page No.
MOUNTING ACCESSORIES 87
Backplate 45681-233 88
Base Cover 45681-380 88Conduit Box 45681-204 88
Sounder Ceiling Plate 45681-311 88
Module Base 38531-822 88
Deckhead Mounting Box 45681-217 89
Metal Deckhead Mounting Box PG16 29600-131 89
Metal Deckhead Mounting Box M20 29600-139 89
Deckhead Adaptor PG16-M20 27249-005 89
Detector Ceiling Tile Mounting Box 45681-309 89
Sounder Ceiling Tile Mounting Box 45681-310 89
Beacon Enclosure 29600-318 89
DIN-Rail Interface Enclosure (4 units) 29600-239 89
DIN-Rail Interface Enclosure (10 units) 29600-240 89
Series 90 to XP95 Base Adaptor 45681-238 90
1.5mm Hexagonal Driver 29600-095 90
MANUAL CALL POINTS 84
XP95 Manual Call Point Red (Surace) 55100-905 85
XP95 Manual Call Point with Isolator Red (Surace) 55100-908 85
Weatherproo Manual Call Point Red 58100-950 85
Weatherproo Manual Call Point Red with Isolator 58100-951 85
Waterproo Manual Call Point Yellow with Isolator 58100-953 85
Transparent Hinged Cover 26729-152 86
Intelligent Heater Base
The Intelligent Heater Base is designed to be used in coldclimates where environmental conditions could result in
either icing or condensation aecting the operation odetectors. It is recommended that the heater base be used
in conjunction with either a Waterproo Base Cover orDeckhead Mounting Box to minimise moisture ingress.
Raises the ambient temperature of adetector chamber by approximately10C
Limits the risk of potential for losso unctionality caused to detectors
installed in these conditions.
45681-219 Intelligent Heater Base
45681-519 Waterproo Base Cover45681-217 Deckhead Mounting Box
MiniDisc Remote Indicator
The MiniDisc Remote Indicator is a light-weight, compactred LED indicator for use in fire protection systems.
Can be used across the entire Apollorange
Small and discrete
Anti-tamper screw to protect againstunauthorised removal
53832-070 MiniDisc Remote Indicator
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
-
7/29/2019 Catalogo Completo Da Apollo 2011
21/144
Analogue Addressable Fire Detection : XP95
21
Product Name Part Number Page No.
STANDARD INTERFACES 78
Input/Output Unit 55000-847 79
Three Channel Input/Output Unit 55000-588 79
Output Unit 55000-849 79
Sounder Control Unit 55000-852 79
Switch Monitor 55000-843 79
Switch Monitor Plus 55000-841 80
Zone Monitor 55000-845 80
MINI INTERFACES 83
Mini Switch Monitor 55000-760 83
DIN-RAIL INTERFACES 81
DIN-Rail Mains Input/Output Unit 55000-797 82
DIN-Rail Sounder Controller (5 Amperes) 55000-182 82
DIN-Rail Input/Output Unit 55000-803 82
DIN-Rail Output Unit 55000-804 82
DIN-Rail Switch Monitor 55000-822 82
DIN-Rail Switch Monitor Plus 55000-821 83
DIN-Rail Zone Monitor with Isolator 55000-812 83
DIN-Rail Dual Isolator 55000-802 83
AUDIO VISUAL SIGNALLING 59
Intelligent Open-Area Sounder Red 55000-001 61
Intelligent Open-Area Sounder White 55000-002 61
Intelligent 100dB (A) Open-Area Sounder Red 55000-278 61
Intelligent 100dB (A) Open-Area Sounder White 55000-279 61
Intelligent 100dB (A) Open-Area Sounder Slow Whoop White 55000-277 69Integrated Base Sounder 45681-278 70
Integrated Base Sounder with Isolator 45681-277 69
Integrated Base Sounder Slow Whoop 45681-291 70
Integrated Base Sounder Slow Whoop with Isolator 45681-290 69
Integrated Base Sounder DIN-Tone with Isolator 45681-300 69
White Cap 45681-292 69
Red Cap 45681-293 69
Ancillary Base Sounder 45681-276 69
Intelligent Open-Area Beacon Red Lens 55000-009 64
Intelligent Open-Area Beacon Clear Lens 55000-010 64
Loop-Powered Beacon Red 55000-877 64Loop-Powered Beacon Amber 55000-879 64
Loop-Powered Beacon Clear Lens/Red Flash 55000-878 64
Beacon Enclosure 29600-318 89
Loop-Powered Beacon Base with Isolator 45681-333 72
Loop-Powered Beacon Base with Standard Flash 45681-335 72
Loop-Powered Beacon Base with Australian Flash 45681-337 72
Intelligent Open-Area Sounder Beacon Red Lens 55000-005 66
Intelligent Open-Area Sounder Beacon Clear Lens 55000-006 66
Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-293 66
Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-294 66
Multi-Tone Open-Area Sounder Beacon Red 55000-291 67
-
7/29/2019 Catalogo Completo Da Apollo 2011
22/14422
Analogue Addressable Fire Detection : XP95
22
Product Name Part Number Page No.
Multi-Tone Open-Area Sounder Beacon White 55000-292 67
Weatherproof Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-298 66
Weatherproof Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-299 66
Weatherproof Multi-Tone Open-Area Sounder Beacon Red 55000-296 67
Weatherproof Multi-Tone Open-Area Sounder Beacon White 55000-297 67
Sounder Beacon Base with Isolator 45681-330 74
Sounder Beacon Base 45681-331 74
Sounder Beacon Base with Australian Tone 45681-336 74
Sounder Beacon Base with Isolator DIN-Tone 45681-334 74
Sounder Beacon Base with NZ Tone 45681-338 74
Sounder Beacon Base Slow Whoop with Isolator 45681-332 74
-
7/29/2019 Catalogo Completo Da Apollo 2011
23/14423
Analogue Addressable Fire Detection : XPERT Cards
23
Apollos Analogue Addressable ranges use patented
XPERT cards. A unique XPERT card provides simple,
user riendly and accurate identiication o detector
location where a coded card, inserted into the base,
is read by any detector once plugged in. All theelectronic components are in the detector but the
location inormation is held in the base which saves
time and increases accuracy during commissioning.
XPERT cardsanalogue addressable re detection
-
7/29/2019 Catalogo Completo Da Apollo 2011
24/144
Analogue Addressable Fire Detection : XPERT Cards
24
Blank XPERT Card
A universal address card supplied with all bases. Using a
coding guide, pips are removed to set the address o theinserted detector.
Simplifies and speeds up installationand commissioning
Uses patented, proven technology
Address remains the same, no matter
how oten detectors are replaced Flexibility to create any address
38531-771 Blank XPERT Card
Pre-Addressed XPERT Cards
Pre-addressed XPERT cards are supplied with pips alreadyremoved.
Saves time and increases accuracyduring commissioning
Uses patented, proven technology
Address remains the same, no matterhow oten detectors are replaced
45682-127 Pre-Addressed XPERT Cards 1-126
XPander XPERT Cards
Address card supplied with all bases. Using a coding guide,
pips are removed to set the address o the inserted device. Simplifies and speeds up installation
and commissioning
Uses patented, proven technology
Address remains the same, no matterhow oten detectors are replaced
Flexibility to create any address
29600-413 XPander Blank XPERT Card (White)
29600-399 XPander Blank XPERT Card (Red)
XPander XPERT cards are not interchangeable with those used with XP95 and Discovery.
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
-
7/29/2019 Catalogo Completo Da Apollo 2011
25/144
In conventional systems detectors
are wired as a circuit or zone. They
signal re conditions to a control
panel by changing rom a high to
low impedance. The panel detects
this impedance change by current
monitoring and identies the zone.
Individual detectors cannot be
identied.
ConventionalFire Detection
-
7/29/2019 Catalogo Completo Da Apollo 2011
26/144
Conventional Fire Detection : Orbis
26
Orbis is a range of conventional detectors which has been
developed with sophisticated technology previously only
found in analogue addressable detectors. Orbis is a range
with modern styling and incorporates a mounting base
which saves installation time.
The range consists o optical smoke and multisensor detectors, seven grades o heat
detector and a range o bases.
Orbisconventional re detection
Each type of detector is available in two
versions:
Standard
Flashing LED
Key features of Orbis:
Wide operating voltage of 8.5 - 33 VDC
Wide operating and storage temperature
-40C to +70C
Electrically compatible with Series 60 and
Series 65 360 visibility of LEDs
Patented FasTest which reduces the time
taken to test detectors
StartUp for fast commissioning
Automatic drift compensation with
DirtAlert warning
SensAlert which uses a flashing LED to
indicate that the detector is not operating
correctly
Algorithms for transient rejection
Attractive and compact design
-
7/29/2019 Catalogo Completo Da Apollo 2011
27/144
Conventional Fire Detection : Orbis
27
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Does not have VdS approval
Orbis Optical Smoke Detector
The Orbis Optical Smoke Detector works using the wellestablished light scatter principle, however, the sensing
technology is radically dierent in design rom previousoptical detectors and signiicantly reduces alse alarms.
Responds well to slow-burning,smouldering ires
Performs well in black and whitesmoke
Extra confirmation of smoke beforealarm signal is given
Reduced incidence of false alarms
Sensing chamber keeps out dust andother airborne contaminants
Operates over a broad range ofvoltages at extremes o temperature
ORB-OP-12001-APO Orbis Optical Smoke Detector
ORB-OP-12003-APO Orbis Optical Smoke Detector
with flashing LED
Orbis Multisensor Detector
The Orbis Multisensor detector benefits from
the same alse alarm reduction technology asthe optical detector.
Responds well to fast-burning, flaming
ires Reduced incidence of false alarms
Increased reliability of detection
Sensing chamber keeps out dust andother airborne contaminants
Operates over a broad range ofvoltages at extremes o temperature
ORB-OH-13001-APO Orbis Multisensor Detector
ORB-OH-13003-APO Orbis Multisensor Detectorwith flashing LED
Orbis Heat Detector
The Orbis Heat Detector monitors temperature by using
a single thermistor which provides a voltage outputproportional to the external air temperature. There areseven classes of heat detector in the Orbis range designedto suit a wide variety o operating conditions.
Can be used for applications where
smoke detectors are unsuitable Ideal in environments that are dirty or
smoky under normal conditions
Reduced incidence of false alarms
Increased reliability of detection
Orbis Heat Detector
Rate-o-Rise, MAT 50CORB-HT-11001-APO A1R - Standard
ORB-HT-11013-APO A1R - with flashing LED
Static, MAT 50CORB-HT-11166-APO A1S - Standard
ORB-HT-11167-APO A1S with flashing LED ORB-HT-11002-APO A2S - Standard
ORB-HT-11014-APO A2S - with flashing LED
Rate-o-Rise, MAT 65CORB-HT-11003-APO BR - Standard
ORB-HT-11015-APO BR - with flashing LED Static, MAT 65C
ORB-HT-11004-APO BS - Standard
ORB-HT-11016-APO BS - with flashing LED Rate-o-Rise, MAT 80C
ORB-HT-11005-APO CR - StandardORB-HT-11017-APO CR - with flashing LED
Static, MAT 80C
ORB-HT-11006-APO CS - StandardORB-HT-11018-APO CS - with flashing LED
MAT (Maximum Application Temperature)
USE A1S or A2S
Choosing a heat detector
-
7/29/2019 Catalogo Completo Da Apollo 2011
28/144
Conventional Fire Detection : Orbis
28
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Orbis LX Base
The Orbis LX Base has two slots for fixing screws at aspacing o 51mm to 69mm. Detectors it into the base one
way only and require clockwise rotation without orce to beplugged in.
One way fit
Detector locking mechanism
ORB-MB-00012-APO Orbis LX Base
TimeSaver Base
The TimeSaver Base is a design that provides installerswith an open working area with ixing holes shaped to
allow a ast mounting procedure.
Grouped terminals to make wiringeasy
Two fixing centres
LED alignment mark
Cable stripping guide
Detector locking mechanism
ORB-MB-00001-APO TimeSaver Base
ORB-MB-00002-APO TimeSaver Base LX (simpliied) version
TimeSaver Diode Base
The TimeSaver Diode Base has the same design as thestandard TimeSaver Base with the addition o a diode. Itis used in systems which house active EOL monitoring for
head removal.
Grouped terminals to make wiringeasy
Two fixing centres
LED alignment mark
Cable stripping guide
Continuity link for voltage testing ofzone wiring prior to commissioning
Detector locking mechanism
Other devices continue to workduring unauthorised removal odetectors
ORB-DB-00003-APO TimeSaver Diode Base
TimeSaver Relay Base
The TimeSaver Relay Base incorporates a single-polevoltage-ree change-over contact or switching external
equipment. When the detector changes to the alarm state,the relay is energised, causing the contact to change state.The contact will remain in this condition until the detector
is reset.
Grouped terminals to make wiringeasy
Two fixing centres
LED alignment mark
Cable stripping guide
Continuity link for voltage testing ofzone wiring prior to commissioning
Detector locking mechanism
Capable of switching up to 30V at 1A
ORB-RB-10004-APO TimeSaver Relay Base
Sav-Wire Base
The Sav-Wire Base is designed to allow Orbis detectors tobe used in Sav-Wire detection and alarm systems.
Grouped terminals to make wiring easy
Two fixing centres
LED alignment mark
Cable stripping guide
Detector locking mechanism
Can be used in Sav-Wiresystems
ORB-SW-10005-APO Sav-Wire Base
-
7/29/2019 Catalogo Completo Da Apollo 2011
29/144
Conventional Fire Detection : Orbis
29
Ancillary devices available for the Orbis range:
Product Name Part Number Page No.
MOUNTING ACCESSORIES 87
Backplate 45681-233 88
Conduit Box 45681-204 88
Sounder Ceiling Plate 45681-311 88
Deckhead Mounting Box 45681-217 89
Deckhead Mounting Box Accessory Kit 45681-218 89
Metal Deckhead Mounting Box PG16 29600-131 89
Metal Deckhead Mounting Box M20 29600-139 89
Detector Ceiling Tile Mounting Box 45681-309 89
Sounder Ceiling Tile Mounting Box 45681-310 89
1.5mm Hexagonal Driver 29600-095 90
Series 65 to Orbis Base Adaptor ORB-BA-10008-APO 90
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Orbis Heater Base
The Orbis Heater base is designed to be used in cold
climates where environmental conditions could result ineither icing or condensation aecting the operation odetectors. It is recommended that the heater base be used
in conjunction with either a Waterproo Base Cover orDeckhead Mounting Box to minimise moisture ingress.
Raises the ambient temperature of adetector chamber by approximately10C
Limits the risk or potential for loss ofunctionality to detectors installed inthese conditions.
ORB-HB-00020-APO Orbis Heater Base45681-519 Waterproo Base Cover
45681-217 Deckhead Mounting Box
TimeSaver Deep Base
The TimeSaver Deep Base is a mounting base for Orbisproducts which has an increased depth which allows or
cables to be inserted into theside o the product.
Enables surface wiring
ORB-MB-00019-APO TimeSaver Deep Base
MiniDisc Remote Indicator
The MiniDisc Remote Indicator is a light-weight, compact
red LED indicator for use in fire protection systems. Can be used across the entire Apollo
range
Small and discrete
Anti-tamper screw to protect againstunauthorised removal
53832-070 MiniDisc Remote Indicator
-
7/29/2019 Catalogo Completo Da Apollo 2011
30/144
Conventional Fire Detection : Series 65
30
Series 65 incorporates well-proven sensing technologies
together with advances in materials and electronics.
Developed rom the highly successul Series 60 range o
detectors, Series 65 includes a chip (integrated circuit) based
on that used in XP95 analogue addressable detectors.
Having a wide operating voltage o 9-33V, the Series 65 detectors can be integratedinto security systems, when used with a relay base. The range consists o ionisation,
integrating ionisation and optical smoke detectors, our grades o heat detector and a
range o bases.
Series 65conventional ire detection
Each type of detector is available in
three versions:
Standard
Flashing LED
Flashing LED and magnet operated
test switch
Key features of Series 65:
Wide operating voltage of 933 VDC
Wide operating and storagetemperature of -20C to +60C
Can be used on security systems
Electrically and mechanicallycompatible with Series 60
Proven detection performance
-
7/29/2019 Catalogo Completo Da Apollo 2011
31/144
Conventional Fire Detection : Series 65
31
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
* Does not have CPD or VdS approval
Does not have VdS approval
Series 65 Ionisation Smoke Detector
The Series 65 Ionisation Smoke Detector uses a low activityradioactive oil to detect ires by irradiating the air in the
smoke chamber and causing a current low. I smoke entersthe chamber, the current low is reduced leading to analarm.
Responds well to fast burning, flamingires
Designed to operate in a variety ofenvironments
Wide operating voltage
Flashing LED and magnet operatedtest switch option55000-217 Series 65 Ionisation Smoke Detector
55000-216 Series 65 Ionisation Smoke Detector with flashing LED 55000-215 Series 65 Ionisation Smoke Detector
with flashing LED and magnetic test switch
55000-208 Series 65 Ionisation Smoke Detector(French)*
Series 65 Integrating Ionisation Smoke Detector
Ionisation detectors use a low activity radioactive oil to
detect ires by irradiating the air in the smoke chamber andcausing a current low. I smoke enters the chamber, thecurrent low is reduced leading to an alarm. Circuitry in
the integrating Ionisation Smoke Detector protects againsttransient levels o smoke above the normal threshold or upto 20 seconds.
Responds well to fast burning, flamingires
Designed to operate in environmentswhere transient levels o smoke maybe expected
Wide operating voltage
Flashing LED and magnet operatedtest switch option
55000-220 Series 65 Integrating Ionisation Smoke
Detector55000-219 Series 65 Integrating Ionisation Smoke
Detector with flashing LED
55000-218 Series 65 Integrating Ionisation Smoke Detector with flashing LED and magnetic
test switch
Series 65 Optical Smoke Detector
The Series 65 Optical Smoke Detector incorporates apulsing LED located within the housing of the detector.
The external detector moulding is identical to that o theionisation detector but has an indicator LED which is clear
in quiescent state but produces red light in alarm.
Responds well to slow-burning,smouldering ires
Well suited for bedrooms and escaperoutes
Unaffected by wind or atmosphericpressure
Wide operating voltage
Flashing LED and magnet operatedtest switch option
55000-317 Series 65 Optical Smoke Detector
55000-316 Series 65 Optical Smoke Detectorwith flashing LED
55000-315 Series 65 Optical Smoke Detector withflashing LED and magnetic test switch
55000-308 Series 65 Optical Smoke Detector (French)*
-
7/29/2019 Catalogo Completo Da Apollo 2011
32/144
Conventional Fire Detection : Series 65
32
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Series 65 Heat Detector
The Series 65 Heat Detector monitors temperature by usinga dual thermistor network which provides a voltage output
proportional to the external air temperature. There are 12heat detectors in the Series 65 range designed to suit a wide
variety o operating conditions.
Can be used for applications wheresmoke detectors are unsuitable
Ideal environments that are dirty orsmoky under normal conditions
Wide operating voltage Flashing LED and magnet operated
test switch optionSeries 65 Heat Detector
Rate-o-Rise, MAT 50C, MSRT 65C
55000-122 A1R - Standard55000-121 A1R - flashing LED 55000-120 A1R - flashing LED and magnetic test
Rate o Rise, MAT 65C, MSRT 85C55000-127 BR - Standard
55000-126 BR - flashing LED
55000-125 BR - flashing LED and magnetic test Rate-o-Rise, MAT 80C, MSRT 100C
55000-132 CR - Standard55000-131 CR - flashing LED
55000-130 CR - flashing LED and magnetic test Static, MAT 80C, MSRT 100C55000-137 CS - Standard
55000-136 CS - flashing LED 55000-135 CS - flashing LED and magnetic test
MAT (Maximum Application Temperature)
MSRT (Maximum Static Response Temperature)
Series 65 Standard Base
The Series 65 Standard Base has been designed to enabledetectors to be itted without the need o orce particularly
useul when itting to suspended ceilings. All Series
65 bases have a one way only it. They can be lockedinto place by a grub screw using a 1.5mm hexagonal
screwdriver - part number 29600-095.
Detector locking mechanism
One way fit
Easy to wire
Contains an earth connector
Contains no electrical parts
45681-200 Series 65 Standard Base
Series 65 Diode Base
The Series 65 Diode Base is designed or use with
conventional systems that have manual call points anddetector bases on the same circuit. The base is itted witha schottky diode on the L1 IN and L1 OUT wiring
terminals. This base can only be used with compatiblecontrol equipment.
Detector locking mechanism
One way fit
Easy to wire
Contains an earth connector
Continues to work duringunauthorised removal o detectors
45681-201 Series 65 Diode Base
-
7/29/2019 Catalogo Completo Da Apollo 2011
33/144
Conventional Fire Detection : Series 65
33
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Series 65 Sav-Wire Base
The Series 65 Sav-Wire Base is designed to allow Series65 detectors to be used in Sav-Wire detection and alarm
systems.
Detector locking mechanism
One way fit
Easy to wire
Contains an earth connector
45681-206 Series 65 Sav-Wire Base
Series 65 Auxiliary Relay Base
The Series 65 Auxiliary Relay Base provides two sets o
volt-ree changeover contacts to acilitate the switching o aremote LED or other auxiliary device.
Detector locking mechanism
One way fit
Easy to wire
Contains an earth connector45681-246 Series 65 Auxiliary Relay Base
Series 65 End-of-Line Relay Base
The Series 65 End-of-Line (EOL) Relay Base is intended foruse with 4-wire circuits and eatures two sets o changeovercontacts and a power supervision relay.
Detector locking mechanism One way fit
Easy to wire
Contains an earth connector45681-247 Series 65 End-of-Line Relay Base 12V
45681-248 Series 65 End-of-Line Relay Base 24V
Series 65 12V Relay Base
The Series 65 12V Relay Base is designed or use in bothire and security systems. For ire systems a jumper on the
PCB is itted to a latching position. For security systemsthe jumper is moved to another position so that the base is
non-latching.
Detector locking mechanism
One way fit
Easy to wire
Contains an earth connector Can be used in fire and security
systems45681-508 Series 65 12V Relay Base
Series 65 Standard Relay Base
The Series 65 Standard Relay Base provides one set o volt-ree, changeover (orm C) contacts that change state when
the detector signals an alarm.
Detector locking mechanism
One way fit
Easy to wire
Contains an earth connector45681-245 Series 65 Standard Relay Base
-
7/29/2019 Catalogo Completo Da Apollo 2011
34/144
Conventional Fire Detection : Series 65
34
Ancillary devices available for the Series 65 range:
Product Name Part Number Page No.
MOUNTING ACCESSORIES 87
Backplate 45681-233 88
Series 65 Base Cover 45681-370 88
Conduit Box 45681-204 88Module Base 38531-822 88
Metal Deckhead Mounting Box PG16 29600-131 89
Metal Deckhead Mounting Box M20 29600-139 89
Detector Ceiling Tile Mounting Box 45681-309 89
1.5mm Hexagonal Driver 29600-095 90
AUDIO VISUAL SIGNALLING 59
Series 65 Sounder Base 45681-512 69
Series 65 Sounder Base with diode 45681-513 69
MiniDisc Remote Indicator
The MiniDisc Remote Indicator is a light-weight, compactred LED indicator for use in fire protection systems.
Can be used across the entire Apollorange
Small and discrete
Anti-tamper screw to protect against
unauthorised removal
53832-070 MiniDisc Remote Indicator
-
7/29/2019 Catalogo Completo Da Apollo 2011
35/144
Two-wireTechnology
In conventional systems, detectors
are hard wired into a circuit or zone.
They signal a re condition to a
control panel by changing rom a
high to low impedance. The panel
detects this impedance change by
current monitoring and identies the
zone. Individual detectors cannot be
identied. In two-wire conventional
systems, re detection and alarm
products are connected to the
same pair o supply wires, makinginstallation quicker, less expensive
and more fexible than traditional our-
wire systems. Two-wire systems are
particularly well suited or small to
medium sized buildings.
-
7/29/2019 Catalogo Completo Da Apollo 2011
36/144
Two-wire Technology : AlarmSense
36
Two-wire AlarmSense has been developed to make the
design and installation o a re detection and alarm system
easier and more economic or small to medium sized
buildings. The range also allows an existing system to be
extended or modied i necessary. This fexibility makes
AlarmSense an excellent choice for use in HMOs.
The two-wire AlarmSense range incorporates a number o technologically advanced
eatures such as patented RemovAlert which alerts the control panel i a detector has
been removed without authorisation.
The entire AlarmSense range has been designed to enable compliance with BS5839-1
and BS5839-6 in addition to EN54 standards. AlarmSense is also compliant with the
Construction Products Directive (CPD).
AlarmSensetwo-wire technology
Key features of AlarmSense include:
Patented RemovAlert head
removal monitoring
Local and general alarm switching Reduced wiring costs
Quick and simple installation
False alarm reduction with non-
priority signalling
Flexible system design
Detectors and call point alarms
identifiable separately
-
7/29/2019 Catalogo Completo Da Apollo 2011
37/144
Two-wire Technology : AlarmSense
37
AlarmSense Optical Smoke Detector
The AlarmSense Optical Smoke Detector works using thelight scatter principle. The detector changes to alarm state
at a pre-set threshold o smoke penetration into the sensingchamber.
Responds well to slow-burning,smouldering ires
Well suited for bedrooms and escaperoutes
360 visibility of LEDs Reduces false alarms
Quick and simple installation55000-390 AlarmSense Optical Smoke Detector
AlarmSense Heat Detector
There are two heat detectors in the AlarmSense range
designed to suit a wide variety o operating conditions. A
static heat detector (CS) which responds only when a ixedtemperature has been reached and a rate-o-rise detector(A1R) which has a ixed upper limit, but in addition,measures the rate o increase in temperature.
Can be used for applications wheresmoke detectors are unsuitable
Ideal environments that are dirty orsmoky under normal conditions
CS detectors are ideal for use inenvironments with rapid temperatureluctuations such asboiler rooms
Reduction of false alarms
360 visibility of LEDs
Quick and simple installation
55000-190 AlarmSense Heat Detector A1R
55000-193 AlarmSense Heat Detector CS
AlarmSense Integrating Optical Smoke Detector
The AlarmSense Integrating Optical Smoke Detector worksusing the light scatter principle. The detector changes to
alarm state at a pre-set threshold o smoke penetration intothe sensing chamber. The detector also has the ability tomonitor and discard transient sources o smoke.
Responds well to slow-burning,smouldering ires
Well suited for bedrooms and escaperoutes
360 visibility of LEDs
Quick and simple installation Designed to operate in environments
where transient levels o smoke maybe expected
Reduces false alarms
20 second delay
55000-391 AlarmSense Integrating Optical Smoke Detector
AlarmSense BaseAlarmSense detectors can only be mounted into theAlarmSense Base. The base is used or installing detectorsthat do not require an integral sounder or sounder beacon.
Detects the removal of a detectorhead and reports a ault
Continues to work duringunauthorised removal odetectors
Quick and simple installation45681-244 AlarmSense Base
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
-
7/29/2019 Catalogo Completo Da Apollo 2011
38/144
Two-wire Technology : AlarmSense
38
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
AlarmSense Alarm Relay
The AlarmSense Alarm Relay enables devices such asbeacons, pillow/bed alarms and radio vibrating or paging
devices to be connected to the ire detection system. Thisallows the system to comply with the requirements o the
DDA.
Ensures DDA compliance
55000-835 AlarmSense Alarm Relay
AlarmSense Manual Call Point
The AlarmSense Manual Call Point is compliant withEN54:11. It is different from other conventional call points
in that it can be detected as an operated call point ratherthan a detector that has changed to the alarm state.
Gives immediate response
Unique identification signalling
Resettable element
55100-894 AlarmSense Manual Call Point (Surace)
MiniDisc Remote Indicator
The MiniDisc Remote Indicator is a light-weight, compact
red LED indicator for use in fire protection systems. Can be used across the entire Apollo
range
Small and discrete
Anti-tamper screw to protect againstunauthorised removal
53832-070 MiniDisc Remote Indicator
AlarmSense Sounder Base
The AlarmSense Sounder Base can only be used withAlarmSense detectors. It is itted with electronic circuitryto monitor the presence o detectors and signals any
unauthorised removal o detector heads. It is supplied witha high or low volume setting and red or white caps areavailable or stand-alone installation.
Detects the removal of a detectorhead and reports a ault
Continues to work duringunauthorised removal o detectors
Quick and simple installation
Provides audible signal and detectionat one point
High and low volume ranges45681-510 AlarmSense Sounder Base
45681-295 Red Cap45681-294 White Cap
AlarmSense Sounder Beacon Base
The AlarmSense Sounder Beacon Base is designed to be
used with AlarmSense detectors only. It is supplied witha high or low volume setting and red or white caps are
available or stand-alone installation.
Sounder range between 70dB(A) and87dB(A)
Detects the removal of a detectorhead and reports a ault
Continues to work duringunauthorised removal o detectors
Quick and simple installation45681-509 AlarmSense Sounder Beacon Base
45681-295 Red Cap45681-294 White Cap
-
7/29/2019 Catalogo Completo Da Apollo 2011
39/144
Two-wire Technology : AlarmSense
39
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
AlarmSense Open-Area Sounder Beacon
The AlarmSense Open-Area Sounder Beacon is designed foruse in open areas.
AlarmSense priority/non priority signalrecognition
Head removal signalling
Single Apollo tone - synchronised
with AlarmSense sounder, sounderbeacon bases
Synchronised flashing red LED onsounder beacons and beacons
Polarity insensitive
55000-017 AlarmSense Open-Area Sounder Beacon
AlarmSense Open-Area Sounder
The AlarmSense Open-Area Sounder has been designed for
use in open areas. AlarmSense priority/non priority signal
recognition
Head removal signalling
Single Apollo tone - synchronised withAlarmSense sounder, sounder beaconbases
Polarity insensitive
55000-018 AlarmSense Open-Area Sounder
AlarmSense Open-Area Beacon
The AlarmSense Open-Area Beacon has been developed foruse in situations where there is a risk that sounders will not
be heard. It is weatherproo and can be used outside.
AlarmSense priority/non priority signalrecognition
Head removal signalling
Synchronised flashing LEDs
Polarity insensitive55000-035 AlarmSense Open-Area Beacon
-
7/29/2019 Catalogo Completo Da Apollo 2011
40/144
Two-wire Technology : AlarmSense
40
Ancillary devices available for the AlarmSense range:
Product Name Part Number Page No.
MOUNTING ACCESSORIES 87
Backplate 45681-233 88
Conduit Box 45681-204 88
Sounder Ceiling Plate 45681-311 88
Module Base 38531-822 88
Metal Deckhead Mounting Box PG16 29600-131 89
Metal Deckhead Mounting Box M20 29600-139 89
Deckhead Adaptor PG16 - M20 27249-005 89
Detector Ceiling Tile Mounting Box 45681-309 89
Sounder Ceiling Tile Mounting Box 45681-310 89
1.5mm Hexagonal Driver 29600-095 90
Apollo makes ordering AlarmSense products for a project easy with a
selection of detector/sounder base or detector/sounder beacon basepackages.
Sounder Base Combination Part Number
AlarmSense Optical Smoke Detector with Sounder Base 55000-392
AlarmSense Integrating Optical Smoke Detector with Sounder Base 55000-393
AlarmSense A1R Heat Detector with Sounder Base 55000-196
AlarmSense CS Heat Detector with Sounder Base 55000-197
Sounder Beacon Base Combination Part Number
AlarmSense Optical Smoke Detector with Sounder Beacon Base 55000-394
AlarmSense Integrating Optical Smoke Detector with Sounder Beacon Base 55000-395
AlarmSense A1R Heat Detector with Sounder Beacon Base 55000-198
AlarmSense CS Heat Detector with Sounder Beacon Base 55000-199
-
7/29/2019 Catalogo Completo Da Apollo 2011
41/144
Traditionally, re detection systems in
industrial and commercial applications
have used hard wired installations.
These systems are generally installed
at the time o construction or
reurbishment, making the laying
o cables less o an issue. Certain
applications do not lend themselves
to this approach, such as occupied
buildings, heritage sites, palaces,
annexes etc. - this is where wireless
systems provide the ideal solution.
WirelessTechnology
-
7/29/2019 Catalogo Completo Da Apollo 2011
42/144
Wireless Technology : XPander
42
XPanderwireless technologyXPander is a system in which individual detectors, call points
and alarm devices and interaces communicate with the
XP95 loop by radio signals. An interace is connected to the
loop in the same way as any other interace, such as an input/
output unit.
Every XPander device is assigned an address and this address is recognised by
the control panel in the same way as the address o any other device connected
directly to the loop wiring. The XPander range benefits from the patented XPERT
technology that is also used in Discovery and XP95. See page 23 or more details.
XPander can be incorporated into ire detection systems in stately homes
and architecturally sensitive buildings where the use o ire cables is either
impractical or undesirable.
Key features of XPander include:
Easy to install
XPERT card addressing
Self-monitoring
Proven technology
No special control panel needed
868MHz radio channels
Up to 31 devices per interface
Up to 5 interfaces per loop
All detectors within the XPander range are
sold with mounting bases.
Please ensure that you have attended an
approved XPander training course prior topurchasing products rom the XPander range.
A site survey tool must be included in the irst
order o XPander products as a site survey
must be carried out prior to installation.
-
7/29/2019 Catalogo Completo Da Apollo 2011
43/144
Wireless Technology : XPander
43
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
XPander Optical Smoke Detector and Mounting Base
The XPander Optical Smoke Detector works on the lightscatter principle and is ideal or applications where slow-
burning or smouldering ires are likely.
Wireless
Performs well in black and whitesmoke
Bi-directional radio communications
XPERT card addressing system 5 year battery life using standard AA
alkaline batteries
XPA-CB-12034-APO XPander Optical Smoke Detectorand Mounting Base
XPander Multisensor Detector and Mounting Base
The XPander Multisensor Detector contains an opticalsmoke sensor and a thermistor temperature sensor whose
outputs are combined to give the inal analogue value.
Wireless
Multisensor technology reduces falsealarms
Increased sensitivity to flaming fires
XPERT card addressing system
5 year battery life using standard AAalkaline batteries
XPA-CB-13032-APO XPander Multisensor Detector and
Mounting Base
XPander Heat Detector and Mounting Base
There are two heat detectors in the XPander range designedto suit a wide variety o operating conditions. A static heat
detector (CS) which responds only when a ixed temperaturehas been reached and a rate-o-rise detector (A1R) whichhas a ixed upper limit, but in addition, measures the rate o
increase in temperature.
Wireless
Can be used in applications wheresmoke detectors are unsuitable
Ideal environments that are dirty orsmoky under normal conditions
CS detectors are ideal for use inenvironments with rapid temperatureluctuations such as boiler rooms
Bi-directional (monitored) radio platform
5 year battery life using standard AAalkaline batteries
XPander Heat Detector and Mounting Base
XPA-CB-11170-APO Rate-o-Rise (A1R) 57degrees
XPA-CB-11171-APO Static (CS) 90 degrees
XPander Input/Output Unit
The XPander Input/Output Unit is a radio based interface andoers two monitored input circuits and two relay outputs. It
can be used or controlling ire doors, ire dampers, smokevents and other ire engineering applications.
Wireless
Monitored switch circuit
Voltage free contacts Capable of switching up to 30V at 1A
5 year battery life using standard AAalkaline batteriesXPA-IN-14011-APO XPander Input/Output Single Unit
XPA-IN-14012-APO XPander Input/Output Dual UnitA mains relay module (XPA-IN-14013-APO) is also available
-
7/29/2019 Catalogo Completo Da Apollo 2011
44/144
Wireless Technology : XPander
44
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
XPander Loop Interface
The XPander Loop Interace can monitor up to 31 XPanderdevices and report each devices status to an intelligent
control panel.
Upgraded to connect up to 31XPander devices to an XP95 loop
Translates radio signals from XPanderdetectors to the control panel
Built in loop isolator Loop-poweredXPA-IN-14007-APO XPander Interace Unit
XPander Manual Call Point
The XPander Manual Call Point is compliant with EN54:11.
It is wireless and is powered by two independent packs o 3AA alkaline batteries with a typical ive year lie.
Wireless
XPERT addressing
Resettable element
Fast response reports an alarm inunder one second
LED to indicate operation
XPA-MC-14006-APO XPander Manual Call Point
XPander Sounder Beacon and Sounder Base
The XPander Sounder Beacon and Sounder Base is wireless
and designed to be used with XPander detectors andmanual call points.
Wireless
Bi-directional (monitored) radioplatorm
Choice of 32 selectable tones
Audible self-test available
Output is between 92dB(A) and106dB(A) at 1m - dependent on tonesetting
XPA-CB-14003-APO XPander Red Sounder Beacon and Red Sounder Base
XPA-CB-14004-APO XPander Amber Sounder Beacon and White Sounder BaseXPA-CB-14005-APO XPander Clear Sounder Beacon and
White Sounder Base
XPander Sounder and Sounder Base
The XPander Sounder and Sounder Base is wireless anddesigned to be used with XPander detectors and manual
call points.
Wireless
Bi-directional (monitored) radio platform
Choice of 32 selectable tones
Audible self-test available
Output is between 92 and 106db(A)at 1m - dependent on tone setting
XPA-CB-14001-APO XPander Sounder and Sounder Base RedXPA-CB-14002-APO XPander Sounder and Sounder Base
White
XPander Survey Tool
The XPander Survey Tool is used at the site survey stage
to ascertain i a site is suitable or an XPander installation.A site survey must be carried out beore XPander can be
installed.
Indicates the suitability of proposeddevice location
XPA-TE-14010-APO XPander Survey Tool
-
7/29/2019 Catalogo Completo Da Apollo 2011
45/144
Wireless Technology : XPander
45
There are four aerials available to complement the XPander range:
XPander Aerial (XPA-AE-14008-APO) which is used to strengthen the radio signals sent betweenthe XPander Interace Unit and XPander devices.
XPander Directional Aerial (XPA-AE-14009-APO) which is used to pick up radio signals rom
outbuildings and annexes. XPander Weather Resistant Vertically Aerial (XPA-AE-14014-APO) which includes 3 metres o
co-ax, surge protector and attenuator. For external use (IP68).
XPander Weather Resistant Directional Aerial (XPA-AE-14015-APO) which includes 3 metres oco-ax, surge protector and attenuator. For external use. (IP54).
-
7/29/2019 Catalogo Completo Da Apollo 2011
46/14446
Flush MountedTechnology
-
7/29/2019 Catalogo Completo Da Apollo 2011
47/144
Flush Mounted Technology : Plateau
47
PlateauThe level-headed detectorPlateau is a major advance in ire detector design, providing
eective detection with minimum intrusion. The Plateau
smoke detector, when installed, is a very slim device. It
is ideal or use in installations where it is impractical or
undesirable to use a standard smoke detector. This might
be or aesthetic reasons, where an architect speciiesunobtrusive ire detection, or it might be or reasons o saety,
where a standard ire detector might be viewed as a hazard,
or example in a prison cell.
Plateau is designed for installation in:
Prestige offices
Listed buildings
Designer boutiques
High-class hotels
Museums
Exclusive residences
-
7/29/2019 Catalogo Completo Da Apollo 2011
48/144
Flush Mounted Technology : Plateau
48
Please check the Apollo website on a regular basis or up-to-date approvals inormation.
Plateau Optical Smoke Detector Flush Mounted
Plateau has been designed or discrete unobtrusive smokedetection and is ideal or prestigious oices and high class
hotels. It operates on the light scatter principle where a lightbeam is transmitted through the cover plate. In the event
o any smoke being in close proximity to the detector, thelight is relected back into the receiver which will changethe alarm state ater conirmation o smoke. Plateau comes
complete with backbox with internal retaining laps andsupporting ring.
Unobtrusive design
Self-checking
Effective detection with minimumintrusion
Aesthetically pleasing
55000-050 Plateau Optical Detector Flush Mounted
Plateau Optical Smoke Detector Vandal Resistant
Plateau operates on the light scatter principle but the lightbeam is transmitted through the cover plate where it isscattered by any smoke that is close to it. The light that
is scattered is registered by the receiver in the detectorwhich will change to the alarm state ater conirmation
o the presence o smoke. The vandal resistant versionincorporates a stainless steel plate or use in custodialinstitutions or where a high degree o protection is required.
Stainless steel plate
Unobtrusive design
Self-checking
Effective detection with minimumintrusion
55000-051 Plateau Optical Smoke Detector Vandal
Resistant
-
7/29/2019 Catalogo Completo Da Apollo 2011
49/144
In addition to standard detectors,
Apollo oers a range o specialist
detectors suitable or a wide variety o
applications.
Specialist
Detectors
-
7/29/2019 Catalogo Completo Da Apollo 2011
50/14450
Specialist Detectors :Flame Detectors
50
Flame Detector