1
2.
3.
4.
5.
6.
7.
1.
MINIMUM ELIGIBILITY CRITERIA (Shall be submitted with Part A of the Offer)
Part 'A' will be opened at 3.30 p.m. on 13.06.2011.
Part 'B' of the tenders will be opened for those only who fulfils the qualifying criteria given in the tender document. The
unopened part 'B' along with Earnest Money deposit for those not fulfilling qualifying criteria will be returned.
Clarifications, if any, required on drawings, schedules, specifications, etc. can be obtained from our Consultant M/s.
Biplab Nandi & Associates, 10 Najrul Sarani, Pakurtala More, Hakimpara, Siliguri - 734001 Phone No - 9434759609, 0353
3290293
The bank will not be bound to accept the lowest tender and reserves the right to accept or reject any or all tenders
without assgming any reason whatsoever.
Bank of Baroda, West Bengal, Sikkim & A & N Island invites sealed tenders in two bid system for the proposed interior &
electrical work of Balurghat Branch, Narayanpur, Najrul Sarani, Opp. Taxi Stand, Balurghat, Dist. Dakshin Dinajpur,
West Bengal-733101. The work is to be completed within 2(Two) weeks.
(Government of India Undertaking)
NOTICE INVITING TENDER
Interested agencies having experience in work of similar nature & magnitude and fulfilling the eligibility criteria given
below may download detailed tender document from Bank's Website http:bankofbaroda.com/tenders.asp
The tenderer should have completed in last three Financial years (i.e. current year & two previous financial year) in
Bank, Govt. or Govt. undertaking and Financial Institutions, Corporate Sectors, etc. minimum 3 (three) similar
Part 'A' envelope (Technical Bid) shall contain : Earnest Money, the documents for satisfying eligibility criteria & the
technical & financial stipulation, if any, of the tenderer & Part 'B' shall contain : financial bid along with a copy of the
tender document, duly signed in all pages both shall be separately sealed & submitted in another sealed envelope to
the Asst. General Manager, Bank of Baroda, West Bengal, Sikkim & A & N Island, BARODA TOWER, Plot No. 38/2, Block GN,
Sector-V, Salt Lake City, Kolkata : 700 091, before 2.30 P.M. on 13.06.2011 along with Earnest money amounting to Rs.
12,000/- by Bank Draft / Pay order in favour of Bank of Baroda shall be submitted in Part 'A'.
Bank of Baroda
2.
3.
4.a) The Tenderer shall furnish copies of :
i) IT Registration Certificate with No.
ii) Sales Tax Registration Certificate with No.
iii) Service Tax Registration Certificate with No.
iv) Electrical Contractor's License with No.
v) Electrical Supervisor’s License with No.
5.
a)
b)
c)
d)
The Tenderer should also submit the following documents along with the Tender.
List of technical persons available on hand, years of their association with the firm & proposed to be engaged for the
subject work, if selected (marked Annexure-IX) ;
List of important plant & machinery available on hand (own) and proposed to be inducted (own & hired to be given
separately) for carpentry & electrical work (marked Annexure-X)
List of works completed in the last (three) financial years under Bank / Govt., Semi - Govt,Govt. undertaking /
Corporate Sectors giving description of work, organisation for whom executed, approximate value of contract at the
time of award, date of award and date of scheduled completion of work, date of actual completion and final value
of contract should also be given (marked Annexure-XI)
marked Annexure - VI
marked Annexure - VII
marked Annexure - VIII
marked Annexure - IV
marked Annexure - V
Bank, Govt. or Govt. undertaking and Financial Institutions, Corporate Sectors, etc. minimum 3 (three) similar
composite work (Interior Furnishing & Electrical) costing not less than Rs. 15.00 lacs in single contract. (Work order &
completion Report in support must be submitted & marked as Annexure-I)
The total contract amount received by the Tenderer during the last 3 financial years should be minimum as 40.00 lacs
per year in contract work. In support of this the Tenderer should submit audited sheet duly Certified by the Chartered
Accountant & marked Annexure-II.
The Tenderer should produce Solvency Certificate from any Nationalised / Scheduled Bank for an amount of 200% of
the advertised Tender value marked Annexure-III.
List of works in hand indicating description of work, contract value, approximate value of balance work yet to be
done and date of award (marked Annexure-XII) 1
e)
1.
2.
3.
4.
5.
6.
7
8.
9.
Contractors will be required to arrange for their own storing. Dismantled materials are to be carted away from site at
their own cost and disposed of in conformity with Municipal regulations.
The quoted rates, are to include cost of all materials, labour and or any other material, all statutory taxes, transport,
handling delivery at site and installation, complete in all respect, as per drawing, directions or instructions of
Employer/Consultant. The quoted rates are also to include dismantling of partitions, counters, old electrical wirings
etc. and stacking serviceable materials and disposal of debris, etc.
Prior approval of the Employer/ Consultant shall be obtained for colour and thickness of laminates to be used in the
work.
Tenderer who will quote the rate must have a local office at Kolkata. This is absolutely essential for day to day
supervision & coordination of the work at site.
All informations are to be fully authenticated & documented failing which the documents submitted will not be accepted.
GENERAL TERMS & CONDITIONS
The tenderer are to visit the site and acquaint themselves with site conditions before quoting rates.
The arrangement for “ Wire Management " is to have prior approval of the Client.
The quoted rates shall remain firm during the entire currency of contract. No price variation for any causes
whatsoever, shall be entertained.
The time of completion shall be two (2) weeks from the date of placement of order.
The offer shall remain valid for acceptance for a period of 30 days from the date of submission of offer.
Payments will be made once on completion by the Employer within 15 days after certification of bill by the Consultant
10% of the total payable amount is to be retained as retention money and will become due for release after expiry of
six months from the date of completion of the installation & subject to satisfactory maintenance of the executed work.
10.
11.
SPECIFICATION OF MATERIALS FOR INTERIOR WORK
Sl.No. Description
1. Laminate
2. Ply & Block Board
3. Glass
4. False Ceiling & Accessories
5. Veneer
6.Textured Wall Paint
7. Glue
8. Locks
9. Aluminium Hardware Fittings
India Gypsum Ltd.
Marino / Greenlam / Century / Archid
Make (s)
Metako / Allen / Crown with ISI Mark
The bank will not be bound to accept the lowest tender and reserves the right to accept or reject any or all tenders
without assgming any reason whatsoever.
Durian / Century / Archid
ICI, Jenson & Nicholson / Asian paint /
Berger
ICI, Spectrum, Heritage
Godrej / Secur / Yale
Green / Century / Archid / Austin
Modi / Indo Ashahi / Float Glass India Ltd.
six months from the date of completion of the installation & subject to satisfactory maintenance of the executed work.
Tenders addressed to Asst. General Manager, Bank of Baroda, West Bengal & Sikkim Region and submitted at his office
at BARODA TOWER, Plot No. 38/2, Block GN, Sector-V, Salt lake City, Kolkata : 700 091, before 2.30 P.M. on 13.06.2011,
accompanied by Earnest Money amounting to Rs. 12,000/- by Bank draft payable to Bank of Baroda and other
documents as mentioned in NIT. Part 'A' of the tenders will be opened at 3.30 P.M. on the same date.Part 'B' will be
opened immediately after opening of Part 'A'.
2
10. Brass Hardware
11.
Floor Spring
12. Screws
13. Casters
14. Sliding Drawers / Channels
15. Furnishing Fabric
16. Leather Foam
17. PVC Flooring
18. Carpet
SPECIFICATIONS OF MATERIALS FOR ELECTRICAL WORK
Sl.No. Description
1. Switch fuse / fuse switch units (HRC) (32A TPN & above)
2. Timer (TSQ 100)
3. Voltmeter & Ammeter
L & T
GE power / SIEMENS / L&T / Schneider
Brass Arts / Vijoy
Evrite Agencies Pvt. Ltd. / Nita Floor Spring
Nettle Fold
Efficient Gadjets
Earl Behari / Efficient Gadjets
A. E. / IMP
Make (s)
Glamour or Favourite (Balla Industries)
Woven type "Harmony" range from "Vimal"
or equivalent
Bhor Industries or equivalent
Armstrong / Krishna / Premier
4. Voltmeter & Ammeter selector switches
5. Phase indicating lamp
6.
7. Capacitor
8. HRC fuses
9. Power Cable : XLPE
10.
11. HRC fuse base & carriers.
12. PVC terminals
13. 1.1 KV grade PVC insulated armoured aluminium cable (ISI marked)
14. 1.1KV 660V grade PVC insulated & sheathed / insulated copper wire &
flexible cords (ISI marked).
15. Moulded case circuit breaker
16. RCCB / ELCB
17. Switch fuse with rewirable fuses. (6A & 32A TPN)
18. Isolator
NATIONAL/FINOLEX/ HAVELLS
KAYCEE / L & T
CROMPTON/SIEMENS
TATA LEVERT/NEUMERIC/ KIRLOSKAR
GLOSTER/INCAB/POLYCAB/CINOLEX
GE power / SIEMENS / L & T / SCHNEIDER
Vaishno / SIEMENS / ROSS controls
SWITCHGEAR
UNIVERSAL / GLOSTER / NATIONAL / NICCO /
FINOLEX/HAVELL'S
L & T / SCHNEIDER/LEGRAND
HAVELL’S / STANDARD
HAVELL’S / STANDARD
LEGRAND/ SIEMENS / L&T
ELMEX / ESSEN
A E / KAPPA SEGC & CONTROLS / CONTROL
GE Power/SIEMENS/L&T/SCHNEIDEV
3
19. Changeover switch (on load type)
20. MCB distribution board
21. Distribution fuse board with rewireable fuses
22. Miniature circuit breaker / MCB type isolator
23. Contractors
24. Auxiliary contractor
25. 1/16 Amp Piano key type switch / flushed type plug socket
26. 6/16 Amp modular switch / socket, module plate & mounting M.S. /
PVC box.
27. 300W, 2 module electronic regulator
Sl.No. Description
28. Ceiling rose
29. Holder
31. Luminous indicating type buzzer with cancellation push.
32. Alarm bell.
33. G.I. pipe
34. Steel conduits (conforming to IS in all respects)
NATIONAL / HOMA / EQUIVALENT
Make (s)
KHERAJ / GETCO
KAY / EPP / ANCHOR / JJ
HAVELL’S / BPC / BOSMA
KAY / EPP / ANCHOR / JJ
CPL (Genius) / ANCHOR (Roma) / CRABTREE
/
MK
ANCHOR (Roma) / CRABTREE / MK
ANCHOR / PRECISION / SSK & RIDER
BEC / SUPREME / AKG
BST / BANSAL
SIEMENS / L & T/BCH
SIEMENS / L & T
LEGRAND / SIEMENS
KENBAR / HAVELLL’S / ELCON / HPL /
CONTROL & SWITCHGEAR.
LEGRAND/ SIEMENS
34. Steel conduits (conforming to IS in all respects)
35. Black enamelled
36. Galvanised
37. Non-metallic PVC conduit pipe
38. Compression type brass gland
39. Cable termination socket
40. Light fitting & lamps
41. Decorative/Ornamental /Chandelier / Light Fittings
42. Ceiling Fan
43. Exhaust fan
44. Industrial type socket & top
45. Telephone wire
46. Telephone Socket
Good local make with minimum wall
thickness of 3 mm. for 19 / 20 mm. and 25mm
sizes & 2.5 mm. for 12mm. sizes
BEC / SUPREME / AKG
BEC / SUPREME / AKG
DOWELL'S
WIPRO or equivalent
DOWELLS / JOHNSON / COMET
PLAZA / KALINGA/ PRECISION/AKG or
equivalent
CROMPTON / POLAR / KHAITAN
CROMPTON / POLAR / KHAITAN
HAVELL’S / CROMPTON / LEGRAND
FINOLEX / RRK/NATIONAL
CRABTREE/MK
CROMPTON / POLAR / KHAITAN / EPC
4
47. Network Cable
48. Contractors
49. STARTERS
FINOLEX or equivalent
L & T / SIEMENS
NORTH WEST / CABTREE
5
Section A : Civil & Furnishing Work
Sl. No. Description of Item Qty. Unit Rate (Rs.) Amount
1 GYPSUM CEILING : Providing and fixing 12.5mm thick Gypboard conforming
to IS 2095-1982 on metal frame suspended from RCC roof having following
sizes:
Intermediate channel – 45 x 0.9 x 15mm to be placed at 1220mm c/c.
Ceiling angle – 25 x 10 x 0.55mm to be hung from the RCC roof with rawl
plug and clip to be placed at 1220mm c/c.
Ceiling Section – 0.55mm x 51.5mm x 26mm x 10.5mm lipping to be fixed
with the intermediate channel with the help of connecting clip placed at
457mm c/c. Jointing and finishing to be done as per manufacturers
guidelines.
Rate shall be inclusive of any vertical ceiling part, spot, tube light, fans, AC
grills, fire and security systems cutouts with framing, and finishing with
necessary jointing compound, paper tape, and two coats of plastic paint.
Rate should be included of cornice, borders, beading etc.
132 Sq.m
2 PLASTER OF PARIS CORNICE : Providing and fixing plaster of paris
cornice(out of 65 x 65mm sections)at junctions of false ceiling,walls and at
other locations. 70 Rmt
3 Solid Partition (Partition Type – 1 as marked in the drawing ) : Providing
and fixing partition framing upto ceiling level. Framing shall consist of 50 x 50
mm wood member, at 600 mm c/c bothways horizontally and vertically.
Above false ceiling, alternate vertical sections to be extended upto main
ceiling and to be fixed with MS cleats. Framing to be covered on both sides
with 6 mm thick BWR plywood finished with 1mm thick laminate of approved
shade and colour, necessary groove work, beadings, moulding and 75 x 12
mm t.w. skirting duly polished. The item is to be finished complete in all
5 Sq.m
ESTIMATE FOR CIVIL, FURNISHING & ELECTRICAL WORK FOR
BALURGHAT BRANCH OF BANK OF BORODA
mm t.w. skirting duly polished. The item is to be finished complete in all
respects. (Tenderer should visit the site and check the actual floor height –
Partition to be measured upto false ceiling height excluding door opening for
Billing purpose)
4 FULL HEIGHT PARTLY GLAZED PARTITION (Partition Type – 2 as
marked in the drawing ): Providing and fixing partition framing upto
ceiling level. Framing shall consist of 50 x 50 mm wood member, at 600
c/c bothways horizontally and vertically. Above false ceiling alternate
vertical sections to extend upto main ceiling and to be fixed with MS
cleats. Framing to be covered on both sides with 6mm thick BWR ply
finished with 1mm thick laminate, necessary groove work, beadings,
moulding and 75 x 12 mm t.w. skirting duly polished. Upto a height of
900 mm from FFL and from 2100 mm upto the false ceiling, the partition
should be made solid / fully blocked; from 900 mm to 2100 mm clear
glass of 8 mm thickness etched as per direction of the Consultant fixed
with t.w. moulding of 19 x 35. The item is to be finished complete in all
respects. (Tenderer should visit the site and check the actual floor
height – Partition to be measured upto false ceiling height excluding
door opening for Billing purpose).
50 Sq.m
5 LOW HEIGHT PARTLY GLAZED PARTITION (Partition Type – 3 as
marked in the drawing ) : Providing and fixing partition framing upto
total height of 1500 mm. Framing shall consist of 50 x 50 mm wood
member, at 600mm c/c bothways horizontally and vertically. Framing
to be covered on both sides with 6mm thick BWR ply finished with 1mm
thick laminate upto 1050 mm height, necessary groove work, beadings,
moulding and 75 x 12 mm t.w. skirting duly polished and above 900
mm level, glazed by 8mm thick 300mm high glass etched as per
approved design upto 450 mm height. The item is to be finished in all
respects. (Partition to be measured excluding door opening for Billing
purpose).
14 Sq.m
6
6 MAIN ENTRANCE DOOR : Providing and fixing fully glazed Aluminium
framed door with approved colour powder coated sections with 101 x
45 x 2.5mm thck alumnium section for top, bootom and middle rail and
50 x 45 x 2.5 mm thick sections for vertical styles and Door frame with
101 x 45 x 2.5 alumnium sections. Glazing with 12mm thick toughened
glass complete with heavy duty floor spring of approved make and
handle complete.
a) For Banking Hall 4 Sq.m
7 FLUSH DOOR : Providing and fixing in position 35 mm solid core flush
door finished with 1mm thick laminate as per design on both sides duly
polished, t.w. lipping on two vertical and horizontal edges having
cylindrical lock, door stopper, brass hinges, etc. Also providing 75 x
62.5mm second class t.w. frame having t.w. lipping fixed in either
surface of the frame duly polished with 3 coats of lacquer melamine
and fixed to the partition frame.
8 Sq.m
8 PARTLY GLAZED DOOR : Providing and fixing in position 25 mm solid
core panel door finished with 1mm thick laminate on both sides upto
1050 mm height, t.w. lipping on two vertical and horizontal edges,
cylindrical door lock, door stopper, etc., 75 x 62.5mm second class t.w.
frame with t.w. lipping, 8 mm thick glass with necessary etching and /
or frosting to be provided as per design / directions, fixed with wooden
mouldings from both sides. All exposed woodwork to be melamine
polished. The work should be finished as per specification, design and
completed in all respects.
10 Sq.m
9 FIXED GLAZING : Providing and fixing in position 12 mm thick
toughened glass, etched as per design fixed in 50 x 50 mm wooden
framework with necessary t.w. moulding in two pieces in front of the6 Sq.m
framework with necessary t.w. moulding in two pieces in front of the
cash / one window team as per design.
10 STORAGE UNIT : Providing and placing in position Storage units
fabricated out of 19mm thick BWP block board on all sides, backing
and separators will be of 6mm thick BWP ply, shelves and shutters will
be of 19mm thick BWR solid ply. The top, sides, shutter front and back
sides (if exposed) to be finished with 1mm thick laminate with
necessary grooves and the exposed edges of block board should be
finished with 6mm t.w. lipping. Inside of the unit will be polished in
matching tone. Unit should be provided with locks, hinges, sliding
drawer channels, handles, ball catchers and tower bolt fixed. There
should also be a 75 x 12 mm t.w. skirting with grooves as per design
polished in matching tone.
20 Sq.m
11 SIDE & BACK UNIT: Providing and placing in position side and back
units fabricated out of 19mm thick BWP block board on all sides,
backing and separators will be of 6mm thick BWP ply, shelves. Shutters
will be of 12mm thick BWR solid ply. The top, sides, shutter front and
back sides (if exposed) to be finished with 1mm thick laminate with
necessary grooves and the exposed edges of block board should be
finished with 6mm t.w. lipping. Inside of the unit will be polished in
matching tone. Unit should be provided with locks, hinges, sliding
drawer channels, handles, ball catchers and tower bolt fixed. There
should also be a 75 x 12 mm t.w. skirting with grooves as per design
polished in matching tone. (Only front area to be measured for
payment.)
6 Sq.m
7
12 TABLE : Providing and placing in position table fabricated out of
19mm thick BWP block board on all sides finished with 1.0 mm thick
laminate on top, 1mm thick laminate on the sides and front. The work
to be completed by fabricating drawers on one side and leg rest.
Inside of the table and drawers should be polished. Drawers have to
be provided with locks and handles and exposed surfaces are to be
finished with 1mm thick laminate. Table edges are to be finished with
t.w. moulding duly polished. There should be a 75 x 12 mm skirting with
grooves duly melamine polished. Exposed edges of the boards will be
finished with t.w. lipping.(including Wire Manager)
a) Branch Manager’s Table ( 6' X 3' ) 1 no.
b) Officer’s Table ( 5' X 2'-6'). 1 no.
c) Cash counters (As per detailed drawing) 4.2 Rmt
d) Staff Tables (4' x 2' 6 " ) as pe drawing for cash shroffing area. 2 nos.
e) Clerk 1 table( 3' X 2'-6'). 1 no
f) Clerk 2table( 8'-6" X 2'-6'). 1 no
13 WRITING LEDGE : Supply, fitting and fixing 19mm thick granite slab at
a height of 1050mm from FFL with machine polished moulded edges
(950 x 300mm) of approved shade and quality to portion of wall,
including cutting chase in wall and mending good the damages, the
slab supporting itself of 50mm dia stainless steel pipe inside filled with
wooden section of appropriate size and shape to form writing ledge.
1 no.
14 VERTICAL BLIND – Providing and fixing 100mm wide vertical Blinds of
approved shade of Vista Levolor / Marvel/ Mac make .15 Sq.m
15 PIN-UP BOARDS : Supplying and fixing pin-up boards fabricated out of
12mm BWP ply covered with 12mm soft board padding and
upholstered with poly propylene fabric @ Rs. 150/- per meter edges of
soft board should have t.w. moulding duly spirit polished.
4 Sq.m
16 DISPLAY PANELS: Supplying and fixing in position frameless double
Acrylic transparent sheet 2'-6"(l) x 1'-6"(w)mounted with mirror
screws/nuts on the wall along with all accessories complete for display
of bank's schemes/posters/notices inserted on it.
1 no
17 CHEQUE DROP BOX : Supplying,fitting and fixing cheque drop box of
size : 2'x2'x6", made of 19mm thk blockboard,1mm thk.laminate
finished.The front facia made of 8mm thick clear float glass with 1"
wide slit for inserting cheques.
1 no
18 PLANTERS : Providing and placing planters ( 450 x 450 x 450 ) of
appropriate size made out of 19 mm block board & outer side finished
with 1mm laminate of appropriate shade & colour in position of plants.6 nos.
8
19 SUGGESTION BOX (450 x 600 x 200) : Providing and fixing suggestion
box made out of 19mm BWP ply and finished with 1mm laminate and
enamel painted on the inside. A 300 mm long slit is to be made in the
front for letters, etc. The work should be completed in all respects.
1 nos.
20 PAINTING : Providing and applying 2 coats of plastic emulsion paint
over 1 coat of primer of approved shade and colour on walls, columns
and ceiling. The job is inclusive of scraping, leveling and preparing the
surface, applying primer, etc.
288 Sq.m
21 ENAMEL PAINING : Providing and applying 2 coats of enamel paint
over 1 coat of primer of approved shade as per direction of the
Architect. The job is inclusive of scraping, leveling and preparing the
surface, applying primer, etc.
72 Sq.m
22 POP PUNNING : Providing and applying Plaster of Paris punning on
average 15mm thickness on ceiling, walls and columns to bring the
surface in plumb line and level. Rate will be inclusive of scraping,
leveling and preparing the surface as also grooves above skirting,
around window and door frames. Rate to include scraping, neeru /
any other finish on the existing plastered surface.
288 Sq.m
23 KOTA STONE PANTRY COUNTER: 5 Rmt
24 WOODEN COUNTER FOR PANTRY: 2.5 Rmt
25 STAINLESS STEEL SINK 1 no
26 Providing & fixing Wall & Column Paneling with 6 mm BWR ply and
1mm thick laminate of approved shade and colourwith 25 x 25
wooden framing at 450 mm c/c bothways.
18 Sq.m
27 Providing & fixing Sparkle series Frosted film of 3M Make to the glasses to
be fixed as per design and pattern including designing of Banks Logo as
directed . ( base price of Film Rs.110 /- per Sft inclusive of tax ).3 Sq.m
28 Fixing Teak Wooden decorative beading 50 mm wide polished as per
direction of the Architect.150 RM
29 PROVIDING & PLACING IN POSITION OF CHAIRS AS UNDER:-
i Revolving chairs for Manager (Godrej make 7001) 1 no
ii Revolving chairs for all Staff (Godrej make 5002T) 8 nos
iii Visitors chairs (Godrej make 1007) S type. 5 nos
30 MULTI SEATER FOR CUSTOMER WAITING AREA OF GODREJ MAKE:-
i 3 Seater 2 no
TOTAL Rs. 0
9
Section B : Electrical Work
1a. Main Switch : Providing & fixing of 415V 125A TPN SFU with HRC fuses
on angle iron frame on wall concealed. Including connection from Meter
board.1 No.
1b. Providing & fixing of 415V 63A TPN SFU with HRC fuses on angle iron
frame on wall. Including connection from generator supply.1 No.
2. Earth Busbar (For Computer System) : Providing & Fixing earth busbar
of 25 x 3 mm copper strip for connection to UPS and earth station 1 RM
3. EARTH BUSBAR : Providing and fixing earth busbar of 50mm x 6mm G.I.
strip on surface for connections etc. as required.1 RM
4. G. I. EARTH PIPE ELECTRODE : Earthing with G. I. earth pipe 4.5 M
long x40mm dia including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering pipe etc. with
charcoal or coke and salt at alternate layer as required complete as
required.
2 Sets
5. Earthing station : 600x600x3mm copper plate earthing station with
earthing resistance less than 2 ohms including watering PVC/GI pipe with
funnel ,excavation till7’0”or as instructed by site-in charge, backfilling with
compaction ,1no 25x3mm copper flats connected to the copper plate till
the existing ground level, copper nuts & bolts, salt, and coal filling in layers
10”x10” masonry chamber with sand plaster ,RCC, or cast iron lid
,inclusive of 5mtr conduiting of earthing of copper 10 SWG in Black
Enameled MS conduit to start from the ground level, complete as directed
in site manual.
1 No.
6. Supplying and laying G.I. earth strip 25x3 at surface for connection to
equipment & at 0.5 M below ground for connection from earth electrode to 50 RMequipment & at 0.5 M below ground for connection from earth electrode to
earth busbar including soldering etc. as required.50 RM
7. CU Earth Wire: Providing & Fixing of 2nos 16sq.m. PVC insulated
copper Wire from earth busbar to UPS & from earth busbar to earth
station.50 RM
8a. 3.1/2 C PVC/A Al cable : Providing & Laying 3.1/2 C 95 sq.mm PVC/A Al
cable along with 2nos 7/10 SWG GI wire as earth continuity wire. 50 RM
8b. 3.1/2 C PVC/A Al cable : Providing & Laying 3.1/2 C 25 sq.mm PVC/A Al
cable along with 2nos 8 SWG GI wire as earth continuity wire. 50 RM
9a. Cable Termination : End connection of the above 3 1/2 core 95 sq.mm
cable by double compression type brass cable gland crimping type
sockets, tapes etc 2 Set
9b. Cable Termination : End connection of the 3.1/2 x 25 sq.mm by double
compression type brass cable gland crimping type sockets, tapes etc 4 Set
10. LT PANEL at Ground Floor :-
Fabricating, assembling, painting, supplying, erecting, testing,
commissioning of Cubicle type LT panel board fabricated out of 2mm
thick CRCA MS sheet with proper earthing attachment with proper earthing
attachment and provision of bottom /top entry/exit for all cables including
indicating lamps in all phases showing ON/OFF condition.
INCOMING
10
1NO 415V 125A TPN SFU(MAINS)with HRC fuse
1NO 415V 63A TPN SFU(GEN) with HRC fuse
SFUS are Panel mounting Type
1 NO 4 strip horizontal (extension type)copper busbar
200A capacity for MAINS
1 NO 4 strip horizontal (extension type)copper busbar 100A capacity for
GENERATOR 1 NO 4P 415 V on load
Change-Over Switch 200A capacity
1No flush square pattern 96mm square 0-500V range AC voltmeter with
phase selector switch of 3 positions and OFF with HRC fuse links for
protection. It should be fitted
on the incoming side of 125A SFU 1
NO square pattern 96mm square 0-200A range AC ammeter with 3 nos
CT of ratio 200/5 A and phase selector switch of 3 positions and OFF. It
should be fixed on the out going side of 125A SFU
OUTGOING
4 NOS 415 V 63A TPN SFU with HRC fuse
The board should be complete with fabrication of all frames, indicating
lamps, danger board, interconnection with PVC insulated unarmoured
single core cable of appropriate sizes. All cables, conduits, flexible
conduits should be neatly laid and armoured should be finished properly
1 No.
11. TPN DB FOR LIGHTING & COMPUTER : MCB-Distribution
Board - Supplying and installation of
415/250V miniature circuit breaker distribution board in 16SWG sheet steel
enclosure, with double door, internally wired, neutral end earth busbar, and
each comprising of following MCBs having short circuit level 10KA & `C`
curve characteristic. Each MCB Distribution board shall comprise of
following and including blank plates, inscription marking, phase neutral and
earth bars, mounted on M.S. Frame on wall including cutting wall and
mending good damages. Incoming - 1 No. 63A TPN MCB
Outgoing – 2nos 32A TP MCB for connection to UPS 18Nos.
10A/16A/25A/32A SP MCB (Make of DB & MCB:
1 No.
10A/16A/25A/32A SP MCB (Make of DB & MCB:
MDS / LT / SIEMENS/HAVELLS)
12. TPN PDB FOR A/C & POWER SS : MCB-Distribution Board Supplying
and installation of 415/250V miniature circuit breaker distribution board in
16SWG sheet steel enclosure, with double door, internally wired, neutral
end earth busbar, and each comprising of following MCBs having short
circuit level 10KA. & `C` curve characteristic. Each MCB Distribution board
shall comprise of following and including blank plates, inscription marking,
phase neutral and earth bars, mounted on M.S. Frame on wall including
cutting wall and mending good damages. Incoming - 1 No. 63A TPN MCB
Outgoing - 12 Nos. 10A/16A/25A/32A SP MCB Make of DB & 2 nos. 32A
TP MCB
1 No.
13a. Sub Main Wiring from LT panel / Busbar to TPN DBs : Supply and
Fixing of Distribution wiring with4 X 10 Sq. mm + 2 X 6 Sq.mm Single
Core 1100V grade PVC insulated unsheathed stranded copper wire in in
concealed 25mm dia PVC Conduit Pipe partly laid over false ceiling &
partly concealing of 25mm dia PVC Pipe in Brick wall / floor / wooden
partition / furniture including including making good the damages. The
supply and laying of PVC Pipe, inspection boxes & other accessories are
included in the rate.
60 RM
11
14. Point Wiring (Concealed Type) – Point Wiring (Concealed Type)
–a)Supply & Fixing Point Wiring (Concealed Type) including circuit (3x1.5
sq mm) FRLS 1.1kV grade unsheathed stranded Copper Wire from DB to
Switchboard & Switch Board to Switch Board & Point Wiring from
switchboard to individual light, ceiling fan ,exhaust fan, wall bracket fan,
call bell etc & 6A Plug Socket with 3X 1.5 Sq.mm Single Core 1100V
grade unsheathed stranded copper wire in concealed 20mm dia PVC
Conduit Pipe partly laid over false ceiling & partly concealing of 20mm dia
PVC Pipe in Brick wall / floor / wooden partition / furniture including
16SWG thick MS Junction Box, CI Circular Boxes with 3mm thick Hylam
Cover ,brass screws and washers painting of JB, cutting of brick wall &
mending good damages. The rate should include supplying and laying of
all materials like PVC conduit, inspection boxes, modular Switch Box, 6A
Plate Type modular Switch, Socket, Brass screws and any other materials
to complete the wiring, making connection and testing etc, painting and
mending good all the damages.
a. Incandescent / Fluorescent / PL Light Points. (from lighting DB) 55 No
b. Wall / Ceiling /Exhaust fan points - do - 20 No.
c. 6A 5pin plug switch socket on same board. - do - 5 No
d. 6A 5pin plug switch socket on separate board. - do - 15 No
e. Call bell point with S & F bell push. - do - 1 No
f. Incandescent / Fluorescent / PL Light Points. from UPSDB 1 nos.
g. 6A 5 pin plug with switch on separate board (from UPSDB) 5 points
15. Power point Wiring : Supply ,Fixing /Laying Power point concealed with
1100V grade single core 2X4 Sq.mm + 1X2.5 Sq.mm unsheathed stranded 1100V grade single core 2X4 Sq.mm + 1X2.5 Sq.mm unsheathed stranded
FRLS Copper Conductor in concealed 20mm dia PVC Pipe partly laid over
false ceiling & partly concealing of 20mm dia PVC Pipe in Brick wall / floor /
wooden partition / furniture including making good damages . The rate
should include supply and laying of all materials like PVC conduit Pipe,
saddles, hooks inspection boxes and any other materials to complete the
wiring, making connection testing, etc. painting and mending good to
damages.
90 RM
(only black enamelled mild steel pipe should be used as conduit.)
16. Providing & Fixing of 16A Switch modular type , 16/6A Socket shutter
type concealed MS Switch Box , Cover etc. for raw power. 6 No
17.a) Power point Wiring for A/C : Power point Wiring - Supply , fixing & laying
Power point concealed with 1100V grade single core 2X6 Sq.mm
+1X4Sq.mm unsheathed stranded FRLS Copper Conductor in 20 mm dia
PVC conduit partly laid over false ceiling and partly concealed in brick
wall/floor including making good damages . The rate should include supply
and laying of all materials like PVC conduit Pipe inspection boxes etc. and
any other materials to complete the wiring, making connection from DB and
to power unit & testing , etc. painting and mending good to damages.
130 RM
(only black enamelled mild steel pipe should be used as conduit.)
18a. Supply and fixing of power unit for A/C as per catalog no.ACPU6M FT 20
Amps of North-West or Havells complete with starter, MCB,Plug,Socket
etc. to be fixed on modular type MS Box embedded including necessary
accessories. Make : North West.
5 Nos
12
19. Lighting & fan (Material & Labour) :
19a. CFL lights Fittings & lamps, Ballast etc for recessed mounting: Providing &
Fixing Phillips FBS 450 / 236 M2 FA HF 2xPL-L 36W (Firey Amber) make
recessed mounting Luminaire with mirror optics designed Gypsum type
ceiling including S & F of 2 x PL – L 36 W CFL lamps, etc. 10 No
19b. Providing and fixing Havells make round shaped recessed mounting
luminaire with mirror optics designed for 2 x PL-C 18W (Philips Cat no. DL
21Plus LHOC 71226399) including S & F of 2 nos. 2 x 18W PL-C lamps
and other accessories.etc. Equivalent makes : Phillips Philips Cat no.
FBH 150/218) including S & F of 2 nos. 2 x PLC – 18W
30 No
19c. Tube lights Fittings & lamps, Ballast etc for surface mounting Providing &
Fixing PHILIPS make surface mounting Luminaire designed for tube lights
(PHILIPS CAT No- TMC 501/ 136 HFor equivalent) including S & F of
ballast ,1x36W tube lights, down rods etc10 No
19d. Tube lights Fittings & lamps, Ballast etc for surface mounting Providing &
Fixing PHILIPS make surface mounting Luminaire designed for tube lights
(PHILIPS CAT No- TMS 2005/ 120(2' WITH CAPS) or equivalent) including
S & F of ballast ,1x20W tube lights, down rods etc3 No
19e. Bonsai light for cash counter. Fittings & lamps, Ballast etc for surface
mounting Providing & Fixing PHILIPS make surface mounting Luminaire
designed for bonsailights (PHILIPS CAT No- FMS 600/ 136 including S &
F of ballast ,1x36W lights.
3 No
19f.1 Wall / Pedestal Fan Oscillating : Providing & Fixing of Wall / Pedestal
fan 400 mm sweep complete with regulator, etc., including 16 Nofan 400 mm sweep complete with regulator, etc., including
interconnecting wiring. 16 No
19f.2 Exhaust Fan : Providing & Fixing 1400 RPM Exhaust Fan Heavy Duty
300mm dia complete with mounting ring, louver, covers, etc including
interconnection wiring, making hole on wall and making good the damages
.
4 Nos.
19g. Call bell : Providing & Fixing call bell/buzzer on suitable board on wall. 1 No
COMPUTER
20. Wiring from DB to UPS & from UPS to UPS DB :
Providing & laying of 2 x 6+1 x 4 sqmm 1100V grade PVC insulated copper
wire, FRLS, (Make- Finolex/Havells) in concealed 25mm dia PVC conduit
(ISI Mark) with all accessories like saddles, hooks, bends, inspection
boxes etc including supply & fixing of PVC conduit over false ceiling / in
slab / beam / ceiling / on wall from DB to UPS & from UPS to UPS DB.
70 RM
21. Industrial Type Plug & Socket for UPS output :
Providing & Fixing on wall in concealed 16 SWG MS box with wall
matching hylam cover 1no 32 A 3 pin Industrial Socket with matching
plug top3 pin neutral & earth type and 1no 32A DP MCB make including
necessary interconnection.
4 No
22. UPS PANEL WITH CHANGE-OVER-SWITCH : Providing &
Fixing of concealed 16 SWG MS sheet metal enclosure of suitable size
consisting of 2 nos 32A change-over-switch, including necessary
interconnections.
1 No
13
23. UPS DB : Supply & Fixing of UPS MCBSPN Distribution Board in 16SWG
sheet steel enclosure, with double door, internally wired, neutral end earth
busbar, and each comprising of following MCBs having short circuit level
10KA. Each MCB Distribution board shall comprise of following and
including blank plates, inscription marking, phase neutral and earth bars,
mounted on M.S. Frame on wall including cutting wall and mending good
damages Incoming 1 No. 32A SPN MCB. 1 no DP 40A RCCB of 300ma
sensitivity .(make-Alstom/Siemens/MDS/Havells)
Outgoing 6 Nos. 10A/16A SP MCB
1 No
24. Wiring from UPSDB to WORK STATION : Providing & laying of
2x4+1x2.5sqmm 1100V grade PVC insulated copper wire, FRLS, (Make-
Finolex/Havells) in concealed 20mm dia PVC conduit (ISI Mark) with all
accessories like saddles, hooks, bends, inspection boxes etc including
supply & fixing of PVC conduit over false ceiling/in slab/beam/ceiling/on
wall/in floor/wooden partition/furniture from UPS DB to work station.
270 RM
(only black enamelled mild steel pipe should be used as conduit.)
25. Work Station : Supply & installation of Work station comprising 1 no 16A
MODULAR switch, 4 nos 6A 5 pin MODULAR socket outlet for UPS circuit
on MODULAR switch board flush mounted on wall/wooden panel/furniture. 10 Set
26. Supply & laying of 2 pair telephone cable througrout / 19mm conduct pipe 160 RM
27. Supply & fixing telephone socket outlet RJ 11 type make MK 8 Nos
28. Supply & laying of 2 core 23 / 35 speaker wair through 19mm PVC pipe 90 RM
29. Supply & fixing of 20 watts ceilling speaker transformer 6 Nos29. Supply & fixing of 20 watts ceilling speaker transformer 6 Nos
30. Supply & instalation of DVD player model no 3026 Philips or equivalent that
of Sony/Samsung.1
31. Supply & instalation of amplifier make Ahuja model no SSB 60 1
TOTAL Rs. 0
14
WORK
INTERIOR WORK
ELECTRICAL WORK
GRAND TOTAL
ESTIMATE OF REFURBISHING WORK OF BANK OF BARODA, BALURGHAT BRANCH
GENERAL SUMMARY
AMOUNT
15