![Page 1: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/1.jpg)
Analysis of Tension Members
Moayyad Al Nasra, Ph.D, PE
(c) Al Nasra
1
![Page 2: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/2.jpg)
Analysis of Tension Members
Moayyad Al Nasra, Ph.D, PE
(c) Al Nasra 2
![Page 3: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/3.jpg)
Analysis of Tension Members
• Types of tension members:
– L- section,
– round bars,
– flat bars,
– double-angle,
– T-section,
– I-section,
– built-up
(c) Al Nasra 3
![Page 4: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/4.jpg)
Strength of tension members AISC 14th edition page 16.1-26
a.) Gross-section
Pn= Fy.Ag AISC D2-1
Pu=Φt.Fy.Ag
Φt=0.90
b.) Net-section
Pn=Fu.Ae AISC D2-2
Pu=Φt.Pn=Φt.Fu.Ae
Φt=0.75
(c) Al Nasra 4
![Page 5: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/5.jpg)
The design strength of a tension member
Φt.Pn, is to be the smaller of the above equations
Where:
Pn = nominal tensile force
Pu = ultimate tensile strength
Fy = yield stress
Fu = ultimate stress
Ae = effective area
Ag = gross area
(c) Al Nasra 5
![Page 6: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/6.jpg)
Net Area
(c) Al Nasra 6
![Page 7: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/7.jpg)
• Net area = gross area – areas of holes
• Holes are usually punched 1/16 inch larger
than the diameter of the bolt. Also the
punching of the hole is assumed to damage or
even destroy 1/16 inch more of the
surrounding metal. Therefore the area of the
hole is 1/8 inch in diameter larger than the bolt
diameter.
• Example 2-1:
– Net Area=An=(3/8)(6)-2[3/4+1/8](3/8)=1.59 in2
(c) Al Nasra 7
![Page 8: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/8.jpg)
Effective area
• To account for the non-uniform distribution of stresses at the connection sections, a reduction factor will be introduced. The further the section from the connection the more uniform the stress becomes
(c) Al Nasra 8
![Page 9: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/9.jpg)
• (concentration of stresses around the holes). Therefore AISC introduced a reduction
• factor, U, so that – Ae=AnU AISC D3-1 (AISC 14th pp. 16.1-27)
• Where U = shear lag factor determined from
table D3.1 AISC 14th pp.16.1-28 – U=1-x/L for tension members see case 2 table D3.1
(c) Al Nasra 9
![Page 10: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/10.jpg)
• (table D3.1 AISC 14th edition steel design
manual shows that for W, M, S section use
U=0.9 for bf≥2/3 d, and use U=0.85 for bf<2/3
d)
• Where:
– L= length of a connection
– X= distance measured from the plane of the
connection to the centroid of the area of the whole
section. Can be obtained from the AISC manual.
(c) Al Nasra 10
![Page 11: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/11.jpg)
• Example: Determine the LRFD tensile
strength of a W10X45 with two lines of ¾
inch bolts in each flange using A572 grade 50
steel, with Fy=50 ksi, and Fu = 65 ksi, and the
AISC specification. There are assumed to be at
least three bolts in each line 4 inches on center,
and the bolts are not staggered with respect to
each other.
(c) Al Nasra 11
![Page 12: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/12.jpg)
(c) Al Nasra 12
![Page 13: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/13.jpg)
• From AISC manual W10x45 (Ag=13.3 in2, d=10.10 in., bf=8.02 in., tf=0.620 in.), Also
• WT5x22.5, x=0.907 in. ( half of W10x45)
• Pu= Φt. Fy.Ag=(0.90)(50)(13.3)=598.5 k
• An= 13.3-4(3/4+1/8)(0.620)=11.13 in2
– But, bf=8.02”>(2/3)d=(2/3)10.1=6.73, from case 7 AISC 14th manual table 3.1, U=0.9 pp. 16.1-28
• Use U=0.9
• Ae=U.An=((0.90)(11.13)=10.02 in2
• Pu=Φt.Fu.Ae=(0.75)(65)(10.02)=488.5 K
• Therefore the LRFD tensile strength of the section is 488.5 K
(c) Al Nasra 13
![Page 14: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/14.jpg)
Bolted splice plates
• For bolted splice plates
• Ae=An≤0.85 Ag
• Example 2-2
• Same as example 2-1
• Ag=(3/8)(6)=2.25 in2
• 0.85Ag=0.85(2.25)=1.91 in2
• Ae=An=1.59 in2 < 0.85Ag=1.91 in2
(c) Al Nasra 14
![Page 15: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/15.jpg)
Effect of Staggered Holes
(c) Al Nasra 15
![Page 16: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/16.jpg)
• The joint will fail at the weakest section
• To compute the net width of a tension member
along a zig-zag section:
– Net width=gross width-diameter of holes along the
zig-zag section + S2/(4g)
•
• Example Determine the critical net area of ¼ “
thick plate. The holes are punched for ¾” bolts
(c) Al Nasra 16
![Page 17: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/17.jpg)
(c) Al Nasra 17
![Page 18: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/18.jpg)
• Solution: Possible sections are abc, and abde.
• Hole diameters to be subtracted =3/4+1/8=7/8 in.
• Net width:
– Abc: 7-7/8 = 6.125 in.
– Abde: 7-2(7/8)+42/(4x3)=6.58 in.
• Therefore the section abc controls, net width=6.125
• Net area=An=6.125(1/4)=1.53 in2
(c) Al Nasra 18
![Page 19: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/19.jpg)
• Example: Design bolts configuration by
optimizing the failure mechanism, using the
previous example.
• Change the value of, S, to make the net width
of abc, the same as the net width of abde.
• 6.125=7-2(7/8)+S2/(4x3) then solve for
S=3.24 inch
(c) Al Nasra 19
![Page 20: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/20.jpg)
Net Area
• In General
– bn=b – Σ dh + Σ (s2/4g)
b dh
s
g
(c) Al Nasra 20
![Page 21: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/21.jpg)
Net Area
• Where
– bn = net width
– b = gross width
– dh = width of hole ( diameter)
– s= pitch spacing
– g = gage spacing
For members of uniform thickness, t, then
An = bn.t
(c) Al Nasra 21
![Page 22: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/22.jpg)
Net Area
• For members of non-uniform thickness, the net
area can be calculated as follows:
• An= Ag – Σ dh.t + [Σ (s2/4g)] . t
• The critical net area is the net area having the
least value. It is obtained by checking all
possible failure paths
(c) Al Nasra 22
![Page 23: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/23.jpg)
Net Area, Example
• Compute the net area of the 7/8 X 12 plate
shown. The holes are for 3/4 –in bolts
3 in
3 in
3 in
3 in
1.5-in
¾ - in. bolts 7/8 X 12 –in plate
(c) Al Nasra 23
![Page 24: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/24.jpg)
Net Area, solution
3 in
3 in
3 in
3 in
1.5-in
A
B
C
D
E
=s
(c) Al Nasra 24
![Page 25: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/25.jpg)
Net Area, Solution
• Net width
– ABCD = 12 – (2)(3/4+1/8)=10.25 in.
– ABECD = 12 – (3)(3/4+1/8) + (2)[1.52/(4x3)]=9.75
in
– The 9.75 is the lowest and it governs
Net area = (9.75)(0.875)= 8.53 in2
(c) Al Nasra 25
![Page 26: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/26.jpg)
Effective Net Areas
• When a member other than a flat plate or bar is loaded in axial tension until failure occurs across its net section, its actual tensile failure stress will be probably be less than the coupon tensile strength of the steel, unless all of the various elements which make up the section are counted so that stress is transferred uniformly across the section
(c) Al Nasra
26
![Page 27: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/27.jpg)
(c) Al Nasra 27
![Page 28: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/28.jpg)
• In the transition region the stress in the connected part of the member may very well exceed Fy, and go into the strain – hardening range. Unless the load is reduced, the member may fracture prematurely. The farther we move from the connection, the more uniform the stress becomes. In the transition region, the shear transfer has “lagged” and the phenomenon is referred to as “shear lag”
(c) Al Nasra 28
![Page 29: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/29.jpg)
• In such a situation, the flow of tensile stress between the full member cross section and the smaller connected cross section is not 100 percent effective. As a result, the AISC Specification (D3) states that the effective net area, Ae, of such a member is to be determined by multiplying as area, A, ( which is the net or gross area or directly connected area) by a reduction factor U. The use of a factor such as U accounts for the non-uniform stress distribution, in a simple manner.
(c) Al Nasra 29
![Page 30: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/30.jpg)
• Ae= An( U )
• The value of the reduction coefficient, U, is affected by the cross section of the member and by the length of its connection.
(c) Al Nasra
30
![Page 31: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/31.jpg)
The area effective in resisting tension can be appreciably increased by shortening the width of the unconnected leg and lengthening the width of the connected leg, as shown
(c) Al Nasra 31
![Page 32: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/32.jpg)
• One measure of the effectiveness of a member such as an angle connected by one leg is the distance, X, measured from the plane of the connection to the centroid of the area of the whole section. The smaller the value of X, the larger is the effective area of the member, and thus the larger is the member’s design strength.
(c) Al Nasra 32
![Page 33: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/33.jpg)
Bolted Members • Should a tension load be transmitted by bolts, A
equals the net area An of the member and U is computed as follows:
• Ae= An( U )
• Table D3.1 of the AISC 14th ed. Specification provides a detailed list of shear lag factors U for different situations pp. 16.1.28.
(c) Al Nasra 33
![Page 34: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/34.jpg)
Example
• Determine the LRFD tensile strength and the ASD allowable tensile design strength for a W12X30 with two lines of ¾ -in diameter bolts in each flange using A572 Grade 50 steel, with Fy
= 50 Ksi, and Fu= 65 ksi, and the AISC Specification. There are assumed to be at least three bolts in each line 4 in. on center, and the bolts are not staggered with respect to each other
(c) Al Nasra
34
![Page 35: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/35.jpg)
• Solution
• Using W12x30 (Ag= 8.79 in2, d= 12.3 in, bf= 6.52, tf= 0.440 in)
• Nominal or available tensile strength= Pn= FyAg = (50 ksi)(8.79 in2)=439.5 k
• A.) Gross section yielding
• LRFD with φt=0.9, φt Pn=0.9(439.5)=395.55 k
• ASD: Ωt= 1.67, Pn/ Ωt=438.5/1.67=263.2 k
(c) Al Nasra 35
![Page 36: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/36.jpg)
• B.)Tensile rupture strength
• An = 8.79- (4)(3/4+1/8)(0.44)=7.25 in2
• Referring to tables in Manual for one half of W12X30 (WT6X15)m we find
• bf=6.52 < (2/3) d= (2/3)(12.3)=8.2 in
• U from Table D3.1 case 7 is 0.85
(c) Al Nasra
36
![Page 37: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/37.jpg)
• Ae= UAn =0.85(7.25)=6.16 in2
• Pn= FuAe=(65)(6.16)=400.56 k
• LRFD: φt=0.75, φt Pn=0.75(400.56)=300.4 k
• ASD: Ωt= 2.00, Pn/ Ωt=400.56/2=200.3 k
(c) Al Nasra
37
![Page 38: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/38.jpg)
Example • Determine the LRFD design strength and the
ASD allowable strength for an A36 (Fy=36 ksi, Fu= 58 ksi) L6X6X3/8 in that is connected at its ends with one line of four 7/8 in diameter bolts in standard holes 3 in on center in one leg of the angle
(c) Al Nasra
38
![Page 39: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/39.jpg)
• Solution:
• Using an L6x6X3/8 (Ag=4.38 in2, y=x=1.62 in) nominal or available strength of L
• Pn= FyAg= (36 ksi)(4.38 in2)= 157.7 k
• A.) Gross section yielding
• LRFD: with φt=0.9, φt Pn=0.9(157.7 k) =141.9k
• ASD: Ωt= 1.67, Pn/ Ωt=157.7/1.67=94.4 k
(c) Al Nasra
39
![Page 40: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/40.jpg)
• B.) Tensile rupture strength
• An = 4.38 in2-(1)(7/8+1/8)(3/8)=4.00 in2
• Length of connection = L= 3(3 in) = 9 in.
• U=1-x/L=1-1.62/9=0.82
• From case 8 AISC 14th manual table D3.1 for 4 or more fasteners in the direction of loading, U= 0.80. Use calculated U=0.82 (if U is calculated per case 2 Table D3.1, the larger value is permitted to be used)
(c) Al Nasra
40
![Page 41: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/41.jpg)
• Ae= AnU=(4.00 in2)(0.82)=3.28 in2
• Pn=FuAe=(58 ksi)(3.28 in2)= 190.2 k
• LRFD: φt=0.75, φt Pn=0.75(190.2)=142.6 k
• ASD: : Ωt= 2.00, Pn/ Ωt=190.2 / 2 =95.1 k
(c) Al Nasra 41
![Page 42: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/42.jpg)
Welded Members • When tension loads are transferred by welds, the rules
from AISC Table D3.1, that are to be determine values for A and U ( Ae as for bolted connections = AU) are follows:
• 1.) Should the load be transmitted only by longitudinal welds to other a plate member, or by longitudinal welds in combination with transverse welds, A is to equal the gross area of the member Ag.
• 2.) Should a tension load be transmitted only by transverse welds, A is to equal the area of the directly connected elements and U is equal 1.0, and An = area of the directly connected element ( Case 3 in Table D3.1)
(c) Al Nasra 42
![Page 43: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/43.jpg)
• 3.) Tests have shown that when flat plates or bars connected by longitudinal fillet welds are used as tension members, they may fail prematurely by shear lag at the corners if the welds are too far apart. Therefore, the AISC Specification states that when such situation are encountered, the length of the welds may not be less than the width of the plates or bars. The letter A represents the area of the plate, and UA is the effective net area. For such situation the values of U to be used ( AISC 14th ed. Pp.16.1.28 Specification Table D3.1, Case 4) are as follows
(c) Al Nasra 43
![Page 44: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/44.jpg)
(c) Al Nasra 44
L
w
L ≥ 2 W use U= 1.0 2W > L ≥ 1.5 W use U= 0.87 1.5W > L ≥ W use U= 0.75
![Page 45: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/45.jpg)
Example • The 1x8 in plate shown in connected to 1x12 in plate with
longitudinal filler welds to transfer a tensile load. Determine the LRFD tensile design strength and the ASD allowable tensile strength of the member if Fy=50 ksi and Fu = 65 ksi
(c) Al Nasra 45
Longitudinal fillet welds L=10 in
W=8 in
PL1X8 PL 1x12
![Page 46: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/46.jpg)
• Solution : Considering the nominal or available tensile strength of the smaller PL 1x8
• Pn= FyAg= (50 ksi)(1x8) = 400 k
• A.) Gross section yielding
• LRFD: with φt=0.9, φt Pn=0.9(400 k)= 360 k
• ASD: : Ωt= 1.67, Pn/ Ωt=400/1.67 = 239.5 k
(c) Al Nasra 46
![Page 47: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/47.jpg)
• B.) Tensile rupture strength
• 1.5 W = 1.5 (8) 12 in > L = 10 > w = 8 in
• U= 0.75 from Table D3.1 Case 4
• Ae= AU= (8 in2)(0.75)=6 in2
• Pn= Fu Ae= (65 ksi)(6 in2)= 390 k
• LRFD: φt=0.75, φt Pn=0.75(390)=292.5 k
• ASD: Ωt= 2.00, Pn/ Ωt=390/2.00=195 k
(c) Al Nasra 47
![Page 48: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/48.jpg)
Example • Compute the LRFD design strength and ASD allowable strength
of the angle shown. It is welded on the ends and sides of the 8-in leg only. Fy = 50 ksi and Fu = 70 ksi
(c) Al Nasra 48
8 in
6 in
L8x6x3/4 X=1.56 in, A=9.9 in2
![Page 49: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/49.jpg)
• Solution: Nominal or available tensile strength of L = Pn= FyAg= (50Ksi)(9.94 in2)= 497 k
• A.) Gross section yielding
• LRFD: with φt=0.9, φt Pn=0.9(497)=447.3 k
• ASD: : Ωt= 1.67, Pn/ Ωt=497/1.67= 297.6
(c) Al Nasra 49
![Page 50: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/50.jpg)
• B.) Tensile rupture strength ( As only one leg of L is connected, a reduced effective area needs to be computed)
• U=1-x/L=1-1.56/6= 0.74
• Ae= AgU=(9.94)(0.74)= 7.36 in2
• Pn= FuAe= (70)(7.36)=515.2 k
• LRFD: φt=0.75, φt Pn=0.75(515.2)=386.4 k
• ASD: Ωt= 2.00, Pn/ Ωt=515.2/2.0=257.6 k
(c) Al Nasra 50
![Page 51: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/51.jpg)
Slenderness Ratio
• The AISC steel design manual specification D1 lists a preferred (but not required) maximum slenderness ration (SR) of 300. Rods and wires are excluded from this recommendation,
• SR=l/r
• l= un-braced length
• r= radius of gyration = sqrt(I/A)
• I= moment of inertia
• A= cross-sectional area
(c) Al Nasra 51
![Page 52: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/52.jpg)
Block Shear
• The formulae used by LRFD (Φt.Pn) and ASD
(Pn/Ωt) to calculate the allowable strengths of
tension members are not always the controlling
criteria. The allowable strength in tension may
be controlled by block shear strength, where
the failure may occur along a path involving
tension in one plane and shear on a
perpendicular plane. So it is possible for a
block of steel to tear out.
(c) Al Nasra 52
![Page 53: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/53.jpg)
Block Shear The cross-hatched parts may tear out
Bolted angle
Bolted W
Section
Shear plane Tension plane
(c) Al Nasra 53
![Page 54: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/54.jpg)
Block Shear • The AISC specifications (J4.3) states that the
block shear design strength of a particular member is to be determined by
– Computing the tensile fracture strength on the net section in one direction and adding to that value the shear yield strength on the gross area on the perpendicular segment
– Computing the shear fracture strength on the gross area subject to tension and adding it to the tensile yield strength on the net area subject to shear on the perpendicular segment. The expression to apply is the one with the larger rupture term
(c) Al Nasra 54
![Page 55: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/55.jpg)
Block Shear
• The AISC specification (J4.3) states that the available strength, Rn, for the block shear rupture design strength is as follows:
• Rn=0.6FuAnv+UbsFuAnt ≤ 0.6FyAgv+UbsFuAnt (AISC 14th ed. Eq. J4-5,pp. 16.1-129 )
• Φ =0.75 (LRFD), Ω = 2.00 (ASD)
• In which
– Anv =net area subjected to shear, in2 (mm2)
– Ant = net area subjected to tension, in2 (mm2)
– Agv = gross area subjected to shear, in2 (mm2)
(c) Al Nasra 55
![Page 56: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/56.jpg)
Shear Block • To account for the fact that stress distribution may
not be uniform on the tensile plane for some connections, AISC introduced a reduction factor, Ubs. Should the tensile stress distribution be uniform, Ubs. = 1.0 according to AISC specification (J4.3) (i.e. gusset plates, single-row beam connection,…). For non-uniform stress tensile stresses, Ubs. =0.5 (i.e. multiple-row beam end connection,…)
• Should the block shear strength of a connection be insufficient, it may be increased by increasing the edge distance and/or the bolt spacing.
(c) Al Nasra 56
![Page 57: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/57.jpg)
Block shear, Example
Determine the block shearing strength
(LRFD, ASD), W12X45 (A242 Grade
50 steel and 7/8-in bolts
2-in 3-in 3-in
5.5-in
(c) Al Nasra 57
![Page 58: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/58.jpg)
Block shear, Solution
Using a W12X45 (tf=0.575-in, bf=8.05-in)
Agv=(4)(8)(0.575)=18.4 in2 (2 each flange)
Anv=(4)[8-2.5(7/8+1/8)](0.575)=12.65 in2 (2.5 bolts each of the 4
sides)
Ant=(4)[1.275-(.5)(7/8+1/8)](0.575)=1.78 in2 (1/2 bolt in tension)
8-in
1.275-in
5.5-in
1.275-in
(c) Al Nasra 58
![Page 59: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/59.jpg)
• Ubs = 1.0 uniforn tensile stress
• Rn=0.6FuAnv+UbsFuAnt ≤ 0.6FyAgv+UbsFuAnt
• Rn= 0.6(70)(12.65)+1.0(70)(1.78) = 655.9 k
• <0.6(50)(18.4)+1.0(70)(1.78)=676.6 k
• Therefore Rn =655.9 k
• LRFD
– Φ. Rn = (0.75)(655.9)=491.9k
ADS
Rn/Ω=655.9/2=327.9k
(c) Al Nasra 59
![Page 60: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/60.jpg)
60
![Page 61: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/61.jpg)
Design of Tension Members
Moayyad Al Nasra, Ph.D, PE
(c) Al Nasra
![Page 62: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/62.jpg)
Review
Analysis of Tension Member
Summary- Suggested Procedure • Step 1: Find the relevant parameters regarding
the tension member, including, length, cross-sectional area, yield stress, ultimate stress, radius of gyration,…
• Step 2: Check the slenderness ratio
– l/r ≤ 300 (preferred )
• Step 3: Find Φt.Pn based on the gross area
– Φt.Pn =0.90(Fy.Ag)
(c) Al Nasra 62
![Page 63: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/63.jpg)
• Step 4: Determine the shear lag factor U, using
AISC Specifications Table D3., pp. 16.1-28
• Step 5: Determine the net area
– An= Ag – Σ dh.t + [Σ (s2/4g)] . t
• Step 6: Find Φt.Pn based on fracture effective
net section
– Ae=U.An
– Φt.Pn = 0.75Fu.Ae
(c) Al Nasra 63
![Page 64: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/64.jpg)
• Step 7: Find Φ.Rn based on block shear
strength
– Rn=0.6FuAnv+UbsFuAnt ≤ 0.6FyAgv+UbsFuAnt
(AISC Eq. J4-5)
• Step 8: Find the lowest value calculated from
steps 3, 6 and 7. The lowest value controls.
(c) Al Nasra 64
![Page 65: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/65.jpg)
Exercise- Analysis of Tension Member
The A572 Grade 50 (Fu=65) tension member shown is connected
with three 3/4 –in bolts. Calculate the design tensile strength, LRFD, and the allowable tensile strength, ASD, of the member
Shea plane Tension plane
2 4 4-in
10-in
3.5-in
2.5-in
L6X4X1/2
20-ft tension member
(c) Al Nasra 65
![Page 66: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/66.jpg)
Exercise- Analysis of Tension Member- solution
• Step 1: L6X4X1/2 form the steel design manual, Ag=4.75 in2, rx=1.91-in, ry=1.14-in, x=0.981-in, …
• Step 2:Check the slenderness ratio, rmin=ry l/r = 20(12)/1.14=210.5 < 300
• Step 3:Find Φt.Pn based on the gross area – Φt.Pn =0.90(Fy.Ag)=0.9(50)(4.75)=231.75 k
– ASD • Pn=Fy.Ag = 50(4.75)=237.5 k
• Pn/(Ω=1.67)=237.5/1.67=142.2 k
• Step 4: Determine the shear lag factor U – U=1-x/L=1-0.981/(2x4)=0.88
– Or U=0.60 form Table D3.1 Case 8 AISC 14th ed. Pp.16.1.228
– Use the larger U, U= 0.88
(c) Al Nasra 66
![Page 67: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/67.jpg)
Exercise- Analysis of Tension Member- solution-cont’d
• Step 5:Determine the net area
– An= Ag – Σ dh.t + [Σ (s2/4g)] . t
– An=4.75-(3/4+1/8)(1/2)=4.31 in2
• Step 6: Find Φt.Pn based on fracture effective
net section
– Ae=U.An = 0.88(4.31)=3.79 in2
– Φt.Pn = 0.75Fu.Ae = 0.75(65)(3.79)= 184.9 k
– ASD
• Pn =Fu.Ae = 65(3.79) =246.4 k
• Pn/Ω =246.4/2.00=132.2 k
(c) Al Nasra 67
![Page 68: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/68.jpg)
Exercise- Analysis of Tension Member- solution-cont’d
• Step 7:Find Φ.Rn based on block shear strength
– Rn=0.6FuAnv+UbsFuAnt ≤ 0.6FyAgv+UbsFuAnt
– Agv =(10)(1/2)=5.0 in2
– Anv =[10-(2.5)(3/4+1/8)](1/2)=3.91 in2
– Ant = [2.5-(1/2)(3/4+1/8)](1/2)= 1.03 in2
– Rn=(0.6)(65)(3.91)+(1.0)(65)(1.03) =219.44k
– Rn =(0.6)(50)(5.0)+(1.0)(65)(1.03)=216.95 k
– Therefore Rn=216.95 k
– Φ. Rn= (0.75)(216.95)= 162.7 k (LRFD)
– ASD, Rn/Ω =216.95/2.00=108.5 k
•
(c) Al Nasra 68
![Page 69: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/69.jpg)
Exercise- Analysis of Tension Member- solution-cont’d
• Step 8: The lowest Value
• LRFD = lowest of (231.75, 184.9,162.7)
• LRFD= 162.7 k
• ASD Lowest of (142.2, 132.2, 108.5)
• ASD =108.5 k
(c) Al Nasra 69
![Page 70: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/70.jpg)
Factors affecting the design decision
• Safety
• Economy
• Compactness
• Relative dimension
• Joint condition
• Technical consideration
(c) Al Nasra
![Page 71: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/71.jpg)
Slenderness Ratio (l/r)
• Applies basically for members under compression
(providing sufficient stiffness to prevent lateral deflection,
buckling)
• Slenderness ratio for members subjected to tension is
limited by AISC steel manual to a max of 300 (in case that
member is subjected to reversed loading, loading during
installation and transportation,…)
• l=un-braced length laterally
• r=radius of gyration=
(c) Al Nasra
![Page 72: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/72.jpg)
Tension Members Design Formulae
• Max l/r= 300, min r = l/300………….(1)
• Pu=Φt.Fy.Ag
• Min Ag= Pu /(Φt.Fy )……….……..(2)
• Pu=Φt.Fu.Ae
• Min. Ae= Pu/(Φt.Fu)………………..(3)
(c) Al Nasra
![Page 73: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/73.jpg)
Tension Members Design Formulae
• Since Ae=U.An
• Min. An=Ae/U=Pu/(Φt.Fu.U)………(4)
• Also
• Min. Ag= Pu/(Φt.Fu.U) + estimated hole areas
………………………………………….(5)
(c) Al Nasra
![Page 74: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/74.jpg)
• Example
– Select W10 section of 25 ft length subjected to
tensile dead load 90 k, and live load of 80 k. The
member has two lines of bolts in each flange for
¾-in bolts. (use A572 grade 50 steel)
– Use LRFD method
(c) Al Nasra
![Page 75: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/75.jpg)
(c) Al Nasra
![Page 76: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/76.jpg)
• Solution
• Calculate the ultimate, factored load, Pu
– Pu= 1.4 PD= 1.4(90)= 126 k
– Pu= 1.2 PD+1.6PL= 1.2(90)+1.6(80)=236 k ……
Controls
– Use Pu=236 k
• Compute the minimum Ag required
– Min Ag= Pu/(ΦtFy)= 236/(0.90x50)= 5.24 in2
(c) Al Nasra
![Page 77: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/77.jpg)
• Or
• Min Ag=Pu/(Φt.Fu.U) + Estimated hole areas
• Assume that U = 0.90 from case 7 AISC
manual, and assume that flange thickness to
the average of W10s sections ( or pick a flange
thickness of W10 section of area 5.24 in2 or
slightly larger) tf=0.395 in
• Min Ag= 236/(0.75x65x0.9) +
4(6/8+1/8)(0.395) =6.76 in2 CONTROLS
(c) Al Nasra
![Page 78: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/78.jpg)
• Slenderness ratio criteria l/r = 300
• Min r = l/300 = 25x12/300 = 1.0
• Select a section of area > 6.76 and r > 1.0
• Try W10x26 ( area = 7.61, min r = 1.36, d=
10.33, bf= 5.77 in., tf= 0.44”)
• Check the section
– Pu = ΦtFy.Ag=(0.90)(50)(7.61) = 342.45 k > 236 k
….. OK
(c) Al Nasra
![Page 79: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/79.jpg)
• From Table D3.1 PP.16.1.28 AISC steel design manual 14th edition, U= 0.85 since bf= 5.77 < 2/3(d)=2/3(10.33) = 6.89” – Use U=0.85 the larger
• An= 7.61-4(6/8+1/8)(0.44) =6.07 in2
• Ae= (U.An) = 0.85(6.07)= 5.16 in2
• Pu= ΦtFu.Ae=0.75(65)(5.16) = 251.5 k > 236 k …. OK
• Check L/r criteria – L/r= 25x12/1.36 = 220 < 300 OK
• Check block shear
(c) Al Nasra
![Page 80: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/80.jpg)
(c) Al Nasra
![Page 81: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/81.jpg)
• Rn=0.6FuAnv+UbsFuAnt ≤ 0.6FyAgv+UbsFuAnt
• Agv=4(8)(.44)=14.08 in2
• Anv=4(8-2.5(3/4+1/8))(0.44)=10.23 in2
• Ant=4(1.2-(0.5)(3/4+1/8))(0.44)=1.34 in2
• Rn=0.6(65)(10.23) +(1.0)(65)(1.34)=486.07 k
• Rn=0.6(50)(14.08)+(1.0)(65)(1.34)=509.5 k
• Therefore use Rn=486.07 k
• ΦRn=(0.75)486.07 =364.6> 236 k O.K
• Use W10X26
(c) Al Nasra
![Page 82: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/82.jpg)
Design of Tension Members-Suggested Procedure
• Step 1: Calculate the ultimate, factored load, Pu
• Step 2: Compute the minimum Ag required based on gross area
– Min Ag= Pu/(ΦtFy)
• Step 3: Assume an appropriate value for U
• Step 4:Compute the minimum Ag based on effective area
– Min Ag=Pu/(Φt.Fu.U) + Estimated hole areas
– The larger of Ag from step 2 or step 4 will control
(c) Al Nasra
![Page 83: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/83.jpg)
Design of Tension Members-Suggested Procedure, cont’d
• Step 5: Use the Slenderness ratio criteria l/r ≤ 300
– Min r = l/300
• Step 6: Select a section of area > the controlling area in step 4 and r > r-value in step 5
• Step 7: Check the section
– Pu = ΦtFy.Ag > the required Pu otherwise select larger section
– Pu= ΦtFu.Ae (After determining U) > Required Pu in step 1 otherwise select larger section
(c) Al Nasra
![Page 84: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/84.jpg)
Design of Tension Members-Suggested Procedure, cont’d
• Step 8 : Check l/r criteria ≤ 300 otherwise
select larger section
• Step 9: Check block shear
– Rn=0.6FuAnv+UbsFuAnt ≤ 0.6FyAgv+UbsFuAnt
– Φ.Rn ≥ required Pu calculated in step 1, otherwise
adjust connection and/or select larger section
(c) Al Nasra
![Page 85: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/85.jpg)
Design of Rods and Bars
• The required area
• AD= Pu/(Φ(0.75).Fu), Φ= 0.75
• Example
• A572 Grade 50 steel rod subjected to tensile dead load of 12 k and tensile live load of 25 k. Find the diameter of the rod.
• Solution
• Pu= 1.2 (12)+1.6(25)= 54.4 K
• AD= 54.4 / (0.75x0.75x65)= 1.49 n2 = πd2/4 d= 1.38 in
• Use 1 ½ in diameter rod of AD= 1.77 in2
(c) Al Nasra
![Page 86: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/86.jpg)
• Exercise : Select the lightest W14 section
available to support working tensile loads of
PD= 200 k and PL= 300 k. The member is to be
30 ft long and is assumed to have two lines of
holes for 1-inch bolts in each flange. There
will be at least three holes in each line 4 in. on
center. (Use steel A572 Grade 50). Use LRFD
method (optional block shear criteria
confirmation).
(c) Al Nasra
![Page 87: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/87.jpg)
• Solution
• Pu= 1.2(200)+1.6(300) = 720 k
• Min Ag= Pu/ΦtFy=720/(0.9x50)= 16 in2
• Assume U=0.90 from AISC Table D3.1 Case 7 and Assume tf= 0.720 in from AISC tables.
• Min Ag= Pu/(Φt..Fu.U) + estimated areas of holes = 720/(0.75x65x0.90) + 4(1+1/8)(0.720) = 19.65 in2
• Min r = l/300 = 12x30/300 = 1.20 in.
• Try W14X68 ( A=20.0 in2, d=14.0 in., bf= 10.0 in., tf= 0.720 in., ry= 2.46 in.)
• Check Pu= Φt.Fy.Ag= 0.90(50)(20.0)= 900 k > 720 k OK
(c) Al Nasra
![Page 88: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/88.jpg)
(c) Al Nasra
![Page 89: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/89.jpg)
• Exercise: Select a standard threaded rod to
resist service loads PD= 15 k and Pl= 18 k,
using A36 steel.
(c) Al Nasra
![Page 90: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/90.jpg)
(c) Al Nasra
![Page 91: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/91.jpg)
• Solution:
• Pu= 1.2x15+1.6x18=46.8 k
• AD= Pu/(Φx0.75xFu) =
46.8/(0.75x0.75x58)=1.434 in2
• Use 1 3/8 in. diameter rod with 6 threads per
inch (AISC Table 7-17, 14th ed. Pp.7-81)
(c) Al Nasra
![Page 92: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/92.jpg)
Built-up Tension Member
• Section D4 and J3.5 (AISC 14th ed. Pp. 16.1-122) of the AISC Specification provides a set of definite rules describing how the different parts of built-up tension members are connected together.
• 1.) When a tension member is built up from element in continuous contact with each other, such as plate and a shape, or two plates, the longitudinal spacing of connectors between those elements must not exceed 24 times the thickness of the thinner plate or 12 in if the member is to be painted, or if it is not to be painted and not to be subjected to corrosive conditions.
• 2.) Should the member consist of unpainted weathering steel elements in continuous contact and be subject to atmospheric corrosion, the maximum permissible connectors spacings are 14 times the thickness of the thinner plate, or 7 in.
(c) Al Nasra
![Page 93: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/93.jpg)
• 3.) Should a tension member be built up from two or more shapes separated by intermitted fillers, the shapes preferably should be connected to each other at intervals such that the slenderness ratio of the individual shapes between the fasteners does not exceed 300.
• 4.) The distance from the center of any bolts to the nearest edge of the connected part under consideration may not be larger than 12 times the thickness of the connected part, or 6 in.
• 5.) For elements in continuous contact with each other, the spacing of connectors are given in Sections J3.3 through J3.5 of the AISC Specification
(c) Al Nasra
![Page 94: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/94.jpg)
Example
• The two C12X30s shown in the figure below have been selected to support a dead tensile working load of 120 k and a 240 k live working load. The member is 30 ft long, consisting of A36 steel, and has one line of three 7/8 bolt in each channel flange 3 in. on center. Using the AISC Specification, determine whether the member is satisfactory and design the necessary tie plate. Assume centers of holes are 1.75 in from the backs of the channels.
(c) Al Nasra
![Page 95: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/95.jpg)
(c) Al Nasra
![Page 96: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/96.jpg)
• Solution: Using C12X30s ( Ag = 8.81 in2 each, tf = 0.501 in, Ix = 162 in4 each, Iy = 5.12 in4 each, y-axis 0.0674 from back of C, ry= 0.762 in)
• Loads to be resisted:
– LRFD: Pn = 1.2(120)+(1.6)(240) = 528 k
– ASD: Pn= 120+240 = 360 k
(c) Al Nasra
![Page 97: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/97.jpg)
• A.) Gross section yielding
• Pn = FyAg=(36)(2x8.81)=634.2 k
– LRFD: with φt=0.9, φt Pn=0.9(634.2)=570.9 k
– > 528 k OK
– ASD: Ωt= 1.67, Pn/ Ωt=634.2/1.67= 379.8 k
– >360 k OK
(c) Al Nasra
![Page 98: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/98.jpg)
• B.) Tensile rupture strength
• An= 2(8.81-(2)(7/8+1/8)(0.501))=15.62 in2
• U=1-x/L=1-0.674/(2x3)=0.89
• Pn=FuUAn=(58)(15.62)(0.89)=806.3 k
– LRFD: φt=0.75, φt Pn=0.75(806.3)=604.7 k
– >528 k OK
– ASD: Ωt= 2.00, Pn/ Ωt=806.3/2=403.1 k
– > 360 k OK
(c) Al Nasra
![Page 99: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/99.jpg)
• Slenderness ratio
• Ix= 2(162)=324 in4
• Iy= 2(5.12)+2(8.81)(5.326)^2=510 in4
• Rx=sqrt(324/17.62)=4.29 in <ry=sqrt(510/17.62)=5.38 in
• Lx/rx=(12x30)/4.29= 83.9 < 300 OK
(c) Al Nasra
![Page 100: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/100.jpg)
• Design of tie plates (AISC Specification D4) • Distance between lines of bolts = 12.00 – 2(1 ¾) = 8.50 in • Minimum length of tie plates = (2/3)8.5)= 5.67 in (say 6 in) • Minimum thickness of tie plate = ( 1/50 ) (8.50) = 0.17 in (
say 3/16) • Minimum width of tie plates = 8.5+2(1 ½)= 11.5 in (say 12
in) • Maximum preferable spacing of tie plates • Least r one C = 0.762 in • Maximum preferable L/r = 300= 12L/0.762 • L=19.05 ft • Use 3/16x6x1 ft 0 in tie plate 15 ft 0 in on center
(c) Al Nasra
![Page 101: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/101.jpg)
(c) Al Nasra
![Page 102: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/102.jpg)
Exercise
• A tension member is to consist of four equal leg angles, arranged as shown in the accompanying illustration to support the service loads, PD = 180 k and PL = 320 k. The member is assumes to be 24 ft long and is to have one line of three ¾ in bolts in each leg. Design the member with 50 ksi steel, Fu = 65 ksi, and including the necessary tie plate. Neglect block shear.
(c) Al Nasra
![Page 103: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/103.jpg)
(c) Al Nasra
![Page 104: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/104.jpg)
(c) Al Nasra
![Page 105: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/105.jpg)
105
![Page 106: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/106.jpg)
Compression Members
Moayyad Al Nasra, Ph.D, PE
(c) Al Nasra
![Page 107: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/107.jpg)
Failure Mechanism
• Flexural bucking, large L/r
• Local buckling, non-compact
• Torsional bucking, non-uniform
• Yielding, very short column
(c) Al Nasra
![Page 108: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/108.jpg)
Bucking depends on
• l/r
• Connection
• Eccentricity
• Material imperfection
• Initial crookedness
• Residual Stresses
(c) Al Nasra
![Page 109: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/109.jpg)
Residual Stresses
(c) Al Nasra
![Page 110: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/110.jpg)
Euler Formula
(c) Al Nasra
![Page 111: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/111.jpg)
• PCr=π2E.I/L2
………………………………………………(1)
• I=Ar2 ………………..……………………(2)
• P/A=Fe= π2E/(L/r)2 ......................................(3)
• Where
• Fe= Critical stress = Critical force/area
• l/r = Slenderness ratio < 200 for columns
• r= radius of gyration =
(c) Al Nasra
![Page 112: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/112.jpg)
• Example : Find the bucking load of W10X30
steel column if
– L= 18 ft
– L= 9 ft
– L= 4.5 ft
(c) Al Nasra
![Page 113: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/113.jpg)
Solution • W10X30 (A=8.84 in2, rx= 4.38 in., ry= 1.37 in.)
• Min r=ry=1.37 in. • L/r=(18x12)/1.37= 157.7 • Fe= π2(29,000 ksi)/(157.7)2 = 11.5 ksi, • Pcr= 11.5(8.84) = 101.8 k
• L/r= (9x12)/1.37=78.8 • Fe= π2(29,000 ksi)/(78.8)2= 46.1 ksi • Pcr=46.1(8.84) = 407.1 k
• L/r= 4.5x12/1.37=39.4 • Fe= π2(29,000 ksi)/(39.4)2= 184.2 ksi • Pcr=184.2(8.84)=1628.6 k
(c) Al Nasra
![Page 114: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/114.jpg)
Effective Length
(c) Al Nasra
![Page 115: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/115.jpg)
• The effective length is the length between the
two inflection points ( points of zero moments)
• K= effective length factor, depends on the joint
condition. (See AISC steel design manual 14th
edition pp. 16.1.511, Table C-A-7.1)
• In practice there is no perfect hinge nor perfect
fixed joint, AISC introduced design values of
K.
(c) Al Nasra
![Page 116: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/116.jpg)
LRFD Column Formulas Compressive Strength for Flexural Buckling of members without Slender Elements
(c) Al Nasra
![Page 117: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/117.jpg)
• Pn=Fcr.Ag (AISC 14th ed., E3-1, pp. 16.1-33) • Pu=ΦPn=ΦcFcrAg, • Φc =0.90 • The flexural bucking stress, Fcr, is determined as follows:
– When Kl/r≤ 4.71 .(sqrt(E/Fy)), (or Fy/Fe≥2.25) – Fcr=[0.658(Fy/Fe)]Fy …………….AISC E3-2 PP.16.1.33) – When Kl/r >4.71 .(sqrt(E/Fy)), (or Fy/Fe<2.25) – Fcr=0.877 Fe …………………….AISC E3-3, PP.16.1.33
• • Fe= π2E/(Kl/r)2 • Pn= nominal axial load • Pu= Design factored load • ΦcFcr=design stress for axial member (Table 4.22, pp.4.322,
AISC 14th edition)
(c) Al Nasra
![Page 118: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/118.jpg)
• Example: Find the design strength of 12 –ft hinged W10x30 column. Use Fy=50 ksi
• Solution • W10x30 ( A=8.84 in2, rx= 4.38 in., ry= 1.37 in.) • K=1.0 for hinged columns • Min r = ry=1.37 • Kl/r=1(12x12)/1.37=105.1 • Kl/r=105.1 < 4.71 (sqrt(29,000/50)) =113 • Fcr=[0.658(Fy/Fe)]Fy • • Fe= π2E/(Kl/r)2= π2(29,000 ksi)/(105.1)2= 25.91 ksi • Fy/Fe=50/25.91= 1.93 • Fcr= [0.6581.93](50)=22.29 ksi • Pu=0.9(8.84)(22.29)=177.38 K • • OR • From the design Tables , AISC 14th edition, PP. 4.324 and for Kl/r =105.1 • ΦcFcr=20.1 ksi • Pu= ΦcFcrA=20.1 (8.84)=177.68
(c) Al Nasra
![Page 119: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/119.jpg)
OR From the design Tables , AISC 14th edition, PP. 4.324 and for Kl/r =105.1 ΦcFcr=20.1 ksi Pu= ΦcFcrA=20.1 (8.84)=177.68
Available Critical Stress for Compression Members, AISC Table 4-22, Fy=50 ksi, pp.4-324
Kl/r ASD, ksi LRFD, ksi
Fcr/Ωc ΦcFcr
104 13.6 20.4
105 13.4 20.1
106 13.2 19.8
119 (c) Al Nasra
![Page 120: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/120.jpg)
• Exercise
• Determine the LRFD design strength for the
15 –ft hinged W10X45 column. Use LRFD
specifications and a steel with Fy=50 ksi.
(c) Al Nasra
![Page 121: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/121.jpg)
(c) Al Nasra
![Page 122: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/122.jpg)
• Solution
• W10x45 (A=13.3, rx=4.32, ry=2.01)
• Kl/r= (1.0)(15x12)/2.01=89.55
• From Table 4.22 – pp.4.318
• ΦcFcr=25.05 ksi
• Pu= ΦcFcrA=25.05(13.3)=333.2k
(c) Al Nasra
![Page 123: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/123.jpg)
Example
(c) Al Nasra 123
![Page 124: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/124.jpg)
Solution
(c) Al Nasra
124
![Page 125: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/125.jpg)
• C15x50 ( A=14.7 in2, Ix=404 in4, Iy=11.0 in4
• A=(3/4)(18)+(2)(14.7)=13.5+29.4=42.9 in2
• Y=[(13.5)(0.375)+(2)(14.7)(8.25)]/42.9=5.77 in
• Ix=(2)(404)+2(14.7)(2.48)2+(13.5)(5/393)2+(1/12)(18)(3/4)3=1382 in4
• Iy=(1/12)(3/4)(18)3+2[11.0+(14.7)(4.799)2]=1063.6 in4
• ry=sqrt(1063.6/42.9)=4.98 in
(c) Al Nasra
125
![Page 126: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/126.jpg)
• KL/r=(12)(20)/4.98 = 48.19
• Referring to AISC Table 4-22
– LRFD : φcFcr=37.94 ksi, φcPn=(37.94)(42.9)=1628k
– ASD: Fcr/Ωc =25.26 ksi, Pn/Ωc =(25.26)(42.9)=1084 k
(c) Al Nasra
126
![Page 127: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/127.jpg)
• Exercise
• Determine the LRFD design strength for the 15
–ft hinged W10X45 column. Use LRFD
specifications and a steel with Fy=50 ksi.
(c) Al Nasra
127
![Page 128: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/128.jpg)
(c) Al Nasra
128
![Page 129: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/129.jpg)
• Solution
• W10x45 (A=13.3, rx=4.32, ry=2.01)
• Kl/r= (1.0)(15x12)/2.01=89.55
• From Table 4.22 – pp.4.318
• ΦcFcr=25.05 ksi
• Pu= ΦcFcrA=25.05(13.3)=333.2k
(c) Al Nasra
129
![Page 130: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/130.jpg)
130
![Page 131: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/131.jpg)
Design of Columns, LRFD – Axially Loaded
Moayyad Al Nasra, PhD, PE
131 (c) Al Nasra
![Page 132: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/132.jpg)
Trial and Error Procedure:
• Calculate the factored axial load, Pu, – Pu= 1.4 PD – Pu= 1.2 PD + 1.6 PL – ….
• Assume (KL/r) ( ~ 50 for common columns) • Find ΦcFcr , form Table 4.22 corresponding to the assumed KL/r • Calculate required area Arequired=Pu/ ΦcFcr • Select a member and calculate the larger of (KL/r)x, or (KL/r)y • Find, ΦcFcr, from table 4.22 (AISC 14th edition), corresponding to the
calculated (KL/r) in step 5 • Calculate ΦcPn=Pu= ΦcFcrA and compare with the required Pu
– If Pu calculated is slightly larger than Pu required The section is satisfactory – If Pu calculated is less than the Pu required select larger section and go to
step 5.
132 (c) Al Nasra
![Page 133: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/133.jpg)
• Example : Select the lightest available W14 section to support the axial compression loads PD =150 k and PL 200 k if KL 14 ft and A572 steel grade 50 is used.
• • Solution : • Pu= 1.2(150)+1.6(200) = 500 k • Assume KL/r = 50 • ΦcFcr from AISC Table 4.22 = 37.5 • Arequired= Pu/( ΦcFcr) =500/37.5 =13.33 in2 • Try W14 X 48 ( A=14.1 in2, rx=5.85 in., ry = 1.91 in.) • (KL/r)y= 12(14)/1.91=87.96 • ΦcFcr= 25.52 ksi from AISC Table 4.22, pp. 4-324 • ΦcPn= 25.52(14.1)= 359.8 k <500 k ………………..N.G. • Try W14X61 (A=17.9 in2, ry= 2.45 in.) • (KL/r)y= 12x14/2.45 = 68.57 • ΦcFcr= 31.93 ksi • ΦcPn= 31.93(17.9)= 571.5 k > 500 k …………………………… O.K. • Subsequent check of W14x53 shows it will not do • Use W14X61
133 (c) Al Nasra
![Page 134: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/134.jpg)
Available Critical Stress for Compression Members, AISC 14th Ed. Table 4-22, Fy=50 ksi
Kl/r ASD, ksi LRFD, ksi
Fcr/Ωc ΦcFcr
65 22.0 33.0
70 20.9 31.4
75 19.8 29.8
80 18.8 28.2
85 17.7 26.5
90 16.6 24.9
134 (c) Al Nasra
![Page 135: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/135.jpg)
LRFD Design Tables
• Procedure
– Calculate Pu, required
– Calculate KL , for the weak axis
– Select a section with Pu calculated > Pu required
135 (c) Al Nasra
![Page 136: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/136.jpg)
• Example same as the previous one
– Pu= 500 k
– KL = 14 ft
– Select W14x61 ( AISC 14th ed. page 4-16)
Available Strength in Axial Compression, Kips, W- shapes, AISC 14th ed. Table 4-1, Fy=50 ksi, PP. 4-16
Shape W14x
Wt/ft 74 68 61 53
Design, LRFD ΦcPn ΦcPn ΦcPn ΦcPn
KL, ft 13 735 671 599 433
14 701 640 571 401
15 667 608 543 369
136 (c) Al Nasra
![Page 137: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/137.jpg)
Example • Select the lightest available W12 section, using
both the LRFD and ASD methods for the following conditions: Fy=50 ksi, PD=250 k , PL=400 k, KxLx=26 ft and KyLy = 13 ft
– By Trial and error
– By Using AISC tables
(c) Al Nasra 137
![Page 138: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/138.jpg)
• Solution: Using trial and error to select a section, using the LRFT expressions, and then checking the section with both the LRFD, and ASD methods.
• LRFD – Pn= (1.2)(250)+(1.6)(400)=940 k – Assume KL/r= 50 – φcFcr==37.5 ksi (AISC Table 4-22, pp 4-323) – A, required = 900/37.5 24 in2
– Try W12X87 (A=25 in2, rx=5.38 in, ry=3.07 in) – (kl/r)x=(12)(26)/5.38=57.99 Governs – (KL/r)y=(12)(13)/3.07=50.81 – φcFcr= 35.2 ksi (Table 4-22) – φcPn=(35.2)*25.6)=901 K<940 k N.G – Try W12x96, φcPn=994 k> 940 OK
(c) Al Nasra
138
![Page 139: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/139.jpg)
• ASD – P=250+400 650 k
– Assume KL/r= 50
– Fcr/Ωc=24.9 ksi (AISC Table 4-22, pp 4-323)
– A, required= 650/24.9 = 26.10 in2
– Try W12x87 (A= 25.6 in2, rx=5.38 in, ry=3.07 in)
– (KL/r)x=(12)(26)/5.38=57.99 Governs
– (KL/r)y=(12)(13)/3.07=50.81
– Fcr/Ωc=23.4 ksi (Table 4-22)
– Pn/Ωc=(23.4)(25.6)=599 k< 650 k N.G.
– Try W12x96, Pn/Ωc=662 k >650 k O.K.
(c) Al Nasra
139
![Page 140: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/140.jpg)
Axially Loaded Compression Members
Sidesway inhibited: there is something present other than just columns and girders to prevent sidesway.
(c) Al Nasra
140
![Page 141: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/141.jpg)
• Sideway Uninhibited: Resistance to horizontal translation is supplied only by the bending strength and stiffness of the girders and beams of the frame in question.
• Rotational Stiffness = ratio of the sum of the column stiffness to the girder stiffness – G=Σ(column stiffness)/ Σ(Girder stiffness) =
Σ(I/L)c/Σ(I/L)g
– For pinned column G=infinite. It is recommended that G be made equal to 10 where such non-rigid supports are used.
– For rigid connection, G=0, but from a practical standpoint use G=1.0
(c) Al Nasra
141
![Page 142: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/142.jpg)
K Factor • To determine K value,( AISC 14th ed. pp 16.1-
512, and pp 16.1.-513)
– Select the appropriate alignment chart (sidesway inhibited, or sidesway uninhibited)
– Compute G at each end of the column and label the values GA and GB as desired.
– Draw a straight line on the chart between the GA and GB values, and read K where the line hits the center K scale.
(c) Al Nasra
142
![Page 143: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/143.jpg)
Alignment Charts – Sidesway Inhibited
(c) Al Nasra 143
GA GB K
0.0
50
0.5
0.5
0.7
1.0
0.0
0.5
50
![Page 144: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/144.jpg)
Alignment Charts – Sidesway Uninhibited
(c) Al Nasra 144
GA GB K
0.0
100
4.0
0.5
2.0
20.0
0.0
4.0
100
![Page 145: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/145.jpg)
Stiffness Reduction Factor • The Alignment Charts were prepared with the
assumption of elastic failure. The chart K values are too conservative and should be corrected by introducing a reduction factor- Stiffness Reduction Factor, SRF, τa=Fcr,inelastic/Fcr,elastic≈(Pu/A)/Fcr,elastic and ≈ (Pa/A)/Fcr,elastic (Table 4.21 AISC 14th Manual, pp 4-321)
(c) Al Nasra
145
![Page 146: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/146.jpg)
Inelastic Buckling • A direct design method for considering inelastic buckling is
presented in the manual. It involves the following steps: – Calculate Pu or Pa and select a trail size – Calculate Pu/Ag or Pa/Ag and pick the SRF τa from Table 4.21 AISC
Manual, pp 4-321. If the Pu/A, or Pa/A is less than the values given in the table, the column is in the elastic range and no reduction needs to be made.
– The value of G, elastic is computed and multiplied by the SRF and K is picked from the chart
– The effective slenderness ratio KL/r is computed and φcFcr or Fcr/Ω is obtained from the manual and multiplied by the column area to obtain Pu or Pa. If this value is appreciably different from the value computed in step 1, another trial column size is attempted and the four steps are repeated.
(c) Al Nasra
146
![Page 147: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/147.jpg)
Example
• Determine the effective length factors for columns EF, FG and KL of the frame shown, assuming that the frame is subject to sidesway and that all of the assumption on which the alignment charts were developed are met.
(c) Al Nasra 147
![Page 148: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/148.jpg)
(c) Al Nasra
148
![Page 149: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/149.jpg)
• K Factors
(c) Al Nasra
149
Column GA GB K
EF 10.00 (2)(69.42)/183.33= 0.76
1.84
FG (2)(69.42)/183.33= 0.76
(69.42+49.75)/183.3= 0.65
1.26
KL (61.67+39.58)/83.3=1.22
39.58/27.33=1.45 1.44
![Page 150: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/150.jpg)
Example • Select a W14 section for column AB in the frame
shown if PD= 250 K, PL = 500 k, and Fy= 50 ksi, and only in-plane behavior is considered. Furthermore, assume that the column immediately above and below AB are approximately the same size as AB, and also that all the other assumption on which the alignment charts were developed are met. What if inelastic behavior is considered.
(c) Al Nasra
150
![Page 151: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/151.jpg)
• AB
• W21x68 W21x68 14 ft
• W21x68 W21x68 14 ft
• 28 ft 28 ft 28 ft 14 ft
(c) Al Nasra
151
![Page 152: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/152.jpg)
Solution • LRFD, Pu=(1.2)(250)+(1.6)(500)=1100 k • ASD, Pa =250+500 = 750 k • A.) Elastic Design
– Beams are W21X68 ( Ix=1480 in4) – Assume KL= 14 ft for columns – Try W14x99 ( A= 29.1 in2, Ix= 110 in4, rx/ry= 1.66) – GA=GB= (2)(110/14)/[(2)(1480/28)]=1.50 – K= 1.48 from sidesway uninhibited charts – Equivalent KyLy=(KxLx)/(rx/ry)=1.48x14/1.66=12.48 ft – LRFD: use W14x99, φcPn=1160 k >1100 k OK (note that 1160 is
an interpolation from Table 4-1, AISC 14th ed. pp. 4-15, 1150 and 1170)
– ASD: Use W14x99, Pn/Ωc = 774 k > 750 k OK (774k is an interpolation from Table 4-1 pp 4-15, 767 and 781)
(c) Al Nasra
152
![Page 153: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/153.jpg)
• B.) Inelastic Design
– Try W14x90 (A=26.5 in2, Ix= 999 in4, rx/ry=1.66)
– LRFD: Pu/A= 1100/26.5=41.51 ksi
– SRF from AISC 14th ed. Table 4-21, pp 4-321 = 0.564 (interpolated between 0.538 and 0.590)
– GA=GB=[(2)(999/14)]/[(2)(1480/28)](0.564)=0.761
– K= from sideway uninhibited charts = 1.42
– KxLx=(1.42)(14)=20
– Equivalent KyLy=KxLx/(rx/ry)=20/1.66=12 ft
– Use W14x99 (1170>1100)
(c) Al Nasra 153
![Page 154: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/154.jpg)
• ASD: – Pa/A=750/26.5=28.30 ksi
– SRF from AISC Table 4-21, pp 4-317=0.302
– GA=GB=[(2)(999/14)]/[(2)(1480/28](0.302) =0.408
– K from Sidesway uninhibited charts = 1.24
– KxLx=(1.24)(14)=KxLx/(rx/ry)=20/1.66=12 ft
– Use 14x99 (780 > 750, AISC 14th ed page 4-15)
– Note Stiffness reduction factor, changed from the previous edition of AISC, that made ASD and LRFD results converge
(c) Al Nasra
154
![Page 155: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/155.jpg)
Design of Base Plates, Concentrically Loaded Columns
155 (c) Al Nasra
![Page 156: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/156.jpg)
• A1=BN = area of the base plate
• Pp=P/A1= Pressure on the concrete foundation
• Usually the area of the concrete foundation “A2” is larger than the area of the base plate A1.
• LRFD allows reduction in the design value of A1 if A2>A1 by a factor
– Sqrt(A2/A1)≤2 for less than full area of concrete support
•
156 (c) Al Nasra
![Page 157: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/157.jpg)
Base Plate Design
• Nominal bearing strength Pp is determined as
– Pp= (0.85 fc’A1) for full area of concrete support
– Pu= ΦcPp=Φc(0.85 fc’A1)
– LRFD equation J8-1, AISC 14th ed. Pp 16.1-132
– Φc=0.65 for bearing on concrete (LRFD)
– Ωc=2.31 (ASD)
(c) Al Nasra 157
![Page 158: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/158.jpg)
Base Plate Design
• Nominal bearing strength Pp is determined as
– Pp= (0.85 fc’A1) sqrt(A2/A1) )≤1.7 fc
’A1
– for less than full area of concrete support
– Sqrt(A2/A1)≤2
– Pu= ΦcPp
– LRFD equation J8-2, AISC 14th ed. Pp 16.1-132
– Φc=0.65 for bearing on concrete (LRFD)
– Ωc=2.31 (ASD)
(c) Al Nasra 158
![Page 159: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/159.jpg)
Base Plate Design
• A1= Pu/ (ΦcPp )
• Where
• A1 should not be less than the dimensions of the column
• A1≥ bfd
(c) Al Nasra 159
![Page 160: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/160.jpg)
Base Plate Design
• For efficient dimensions, N and B can be selected such that
• N=√A1+0.5(0.95 d -0.80bf)
• And B=A1/N
(c) Al Nasra 160
![Page 161: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/161.jpg)
Base Plate Thickness
• Plate thickness, t
• tmin=(l)(sqrt(2Pu/(0.9FyBN)) LRFD
• tmin=(l)(sqrt(3.33Pu/(FyBN)) ASD – AISC 14th ed, eqns 14-7a, and 14-7b, pp. 14-6
• Where, – l=max(m,n,λn’)
• m=(N-0.95d)/2
• n= (B-0.8bf)/2
• n’ = sqrt(dbf)/4
(c) Al Nasra 161
![Page 162: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/162.jpg)
Base Plate Thickness
(c) Al Nasra 162
𝛌 =𝟐 𝐗
𝟏+ 𝟏 − 𝐗≤ 𝟏
AISC 14th edition, 14-5, pp. 14-5
X can be obtain from for following (AISC 14th ed. 14-6a
and 14-6b pp. 14-5)
For LRFD
𝐗 = 𝟒𝐝𝐛𝐟
(𝐝+ 𝐛𝐟)𝟐
𝐏𝐮
∅𝐜𝐏𝐩
And for ASD
𝐗 = 𝟒𝐝𝐛𝐟
(𝐝+ 𝐛𝐟)𝟐 𝛀𝐜𝐏𝐮
𝐏𝐩
![Page 163: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/163.jpg)
• Example
• Design a base plate with A36 steel for W12x106 column with a dead working load of 100 k and a working live load of 420 k. The concrete 28-day strength is 4 ksi. Footing size is 12 ft by 12 ft
•
• Solution
• Using W12x106 ( d= 12.9 in., bf= 12.2 in.)
• Pu= 1.2(100)+1.6(420)=792 k
• A2=12x12(12x12)=20,736 in2
163 (c) Al Nasra
![Page 164: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/164.jpg)
Example (cont’d)
• Note that A2 is many times larger than hat will be the base plate area, less than full concrete area will provide support, and sqrt (A2/A1) can be taken as 2 ( max is 2).
• Pp= (0.85 fc’A1) sqrt(A2/A1) )≤1.7 fc
’A1
• Pu= ΦcPp=(0.65)(0.85(4)(2) )A1=792
• Solve for A1, A1=179.2 in2
• Base plate must be larger than the column dimensions=12.9(12.2)= 157.38 in2 OK
• N=sqrt(179.2)+0.5(0.95(12.9)-0.8(12.2))=14.6 in
• Use N=15 in
(c) Al Nasra 164
![Page 165: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/165.jpg)
Example,cont’d
• B=A1/N=179.2/15=11.9 in use 13 in
• Use 15x13 plate
(c) Al Nasra 165
![Page 166: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/166.jpg)
Checking the bearing strength of the concrete
• ΦcPp=Φc(0.85)fcA1(sqrt(A2/A1))
• =(0.65)(0.85)(4.0)(13x15)(2)=862 k
• >792 O.K.
• Pp=862/0.65=1326 k
166 (c) Al Nasra
![Page 167: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/167.jpg)
Thickness Design
• Computing m,n,n’
• m= (N-0.95d)/2=(15-0.95(12.9))/2=1.37 in
• n= (B-0.8bf)/2=(13-0.8(12.2))/2=1.62 in
• n’ = sqrt(dbf)4= sqrt(12.9x12.2)/4 = 3.14 in
• X=((4x12.9x12.2)/(12.9+12.2)2[792/(0.65x1326)]
• X=0.92
• l= max [1.37,1.12,(0.92x3.14=2.88)]=2.88
• tmin=(l)(sqrt(2Pu/(0.9FyBN)) LRFD
167 (c) Al Nasra
![Page 168: Analysis of Tension Members · The design strength of a tension member L t.P n, is to be the smaller of the above equations Where: P n = nominal tensile force P u = ultimate tensile](https://reader030.vdocuments.site/reader030/viewer/2022021517/5b2dcdeb7f8b9ac56e8c1b7c/html5/thumbnails/168.jpg)
Thickness Design, cont’d
• t = 2.88 (sqrt(2x792/(0.9x50x15x13))=1.22 in
• Use 1.25 inch
• Use plate of 13”x15”x1.25” as minimum dimsions
(c) Al Nasra 168