Download - 13_25-30 (1)
13SW
ITCHGEAR
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-25
Siemens / Speedfax Previous folio: 13-37
Protective Relays & SCADA SystemsSCADA Substation Automation General
OPCDNP
Station Bus IEC 61850 (Ethernet)
Protection, Control, MeteringPeer to Peer or Goose
Capable
DNPProtection, Control, Metering
Modbus, DNP, Profibus DPProtection, Control, Metering
Siemens PLC’s
Siemens Siprotec Relay (see Siprotec
specific info on page 13-26)
HMI Client
SICAM Remote
Terminal Unit
SICAM Station Mngr.
SICAM PAS & SICAM StationManager IISICAM PAS (Power Automation System)can meet all the demands made of adistributed substation control system –both now and in the future, too. SICAMPAS was conceived as an open system,i.e., besides providing standardized datatransfer processes, it features userinterfaces for the integration of system-specific tasks. SICAM PAS can thus beintegrated with ease in existing systemsand can be used for system integration.With modern diagnostics, it optimallysupports commissioning andmaintenance. SICAM PAS is clearlystructured and reliable, thanks to its open,fully documented and tested system. SICAM StationManager II combinesextensive IED integration capabilities, anIEC 1131 compliant programminginterface, some of the best configurationand diagnostic tools in the industry, andvarious advanced features like WANsupport, data encryption and HTML servercapabilities, to make it a perfectSubstation Data Concentrator.Major Features and Benefits:
▪ Built-in power supply supporting 48 VDC,125 VDC, and 115 VAC power inputs
▪ Three PC-104 card slots (instead of two);Support for new EPIC processor
▪ Supports two Ethernet fiber converters;Demodulated IRIG-B input
▪ Completely enclosed packaging; RS-485switches mounted on outside of chassis
▪ StationManager II is completely softwarecompatible with StationManager I
ICCP Protocol Communications▪ Unexpected events occur in the real
world. ICCP runs in “real world”conditions
▪ Secure communications are required tosupport confidentiality, integrity andavailability. ICCP/NT supports securecommunication using the ICCP PKIsecurity standard
▪ With critical communications, reliableproducts are of utmost importance
SIPROTEC with IEC 61850 – for moreefficient power automationSIPROTEC – the standard for numericalprotective relaying – has established itselfright across the market. Besides thecommon system platform and the uniqueDIGSI 4 service software that may be usedfor all protective devices, it also supportsthe new IEC 61850 communicationstandard. A potential that offers even moreefficiency easily and conveniently.IEC 61850 – what it is and what it canachieveUsers and manufacturers jointly developedthe new international standard IEC 61850.It was approved in early 2004. The agreedaim of this standard is to arrive at a
complete communication solution forsubstations, thus providing users withinteroperability among different makes onthe basis of Ethernet technology. Thisopens up a whole new dimension inefficient substation management. Not onlyshort-term savings in operation andmaintenance, but also simplifiedengineering, less complexity, and longtermexpandability can make you one of thewinners in tomorrow’s power market.Progress. It’s that simple.HMI ClientUsing a local or web-based HMI from theSICAM PAS you can monitor and control allparts of a system from a central point. Theclear display of the operating situationallows you to react fast; you consequentlyreduce your operating costs and canquickly restore power in the event ofmalfunctions. As an integrated overallsystem, SICAM PAS supports you all theway from the bay level to the controlcenter interface with fast data handling,with the flexibility of a programmable-logiccontroller and with the reliability philosophyof a classic telecontrol unit. Availability andflexibility will help you create state-of-the-art, monitoring, control and protectionconcepts in power automation.
Sect_13_Speedfax2007 4/26/07 12:26 PM Page 13-25
13SW
ITCH
GEAR
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog13-26
For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.
Siemens / Speedfax Previous folio: 13-38
Protective Relays & SCADA SystemsSIPROTEC Protective Relays GeneralOverviewHigh-performance protective relayingcomes into its own when it’s a questionof minimizing power system operationgcosts.
Uncomplicated operation, convenientcommissioning tools and flexiblecommunication are all importantelements when service and maintenancecosts have to be reduced. The SiemensSIPROTEC family with its protectionrelays and bay control units is anintegrated system for medium-voltage toextra-high-voltage applications.
Numerical protection systems are nothingnew; after all, Siemens has more than 25years experience in this field. Althoughsystem hardware is still often referred toas protection equipment or units – aswas once the case with analogtechnology – it can now do so muchmore. These relays not only handle faultdetection and location tasks but alsocontrol, metering and monitoringfunctions. And it is these additionalfunctions – impossible before the adventof numerical technology – which offermajor cost-cutting potential.
IEC 61850 SIPROTEC — the standard for numericalprotective relaying — has establisheditself right across the market. Besides thecommon system platform and the uniqueDIGSI 4 service interface that may beused for all protective devices, it alsosupports the new IEC 61850communication standard. A potential thatoffers more efficiency, easily andconveniently. With SIPROTEC relays andbay control units from Siemens we offerall the advantages of an expert andinnovative partner in the field ofprotective relaying and substationautomation. We bring you attractivelypriced intelligent solutions by payingparticular attention to lowering your lifecycle and system management costs.These solutions are the first onesavailable on the market with theinternational IEC 61850 standard. Toenable you to profit from theseadvantages as quickly as possible,Siemens collaborated in the preparationof this international standard and madeevery effort to ensure no time was lost inbringing it out. The result is certainlyworth a look, because SIPROTEC and
other Power Automation products andSiemens systems are available on thebasis of the IEC 61850 standard and caneven be retrofitted in systems suppliedsince 1998.
System advantages
▪ One bay, one unitThe SIPROTEC 4 relay family offers fullyintegrated protection, control, monitoring,and automation functions incorporated ina single device. For many applications,this product contains all the functions youneed to meet all your protection andcontrol requirements with just one unitper bay, saving on investment andinstallation costs and enhancingavailability.
▪ DIGSI 4 – one tool for all tasks andproducts
DIGSI 4 is a computer program designedfor all SIPROTEC relays. DIGSI 4 offersusers a universal tool for all support tasksfrom setting and commissioning ofdevices to simple analysis anddocumentation of system faults. Ourpowerful analysis tool speeds up trouble-shooting and supplies important serviceinformation.
Sect_13_Speedfax2007 4/26/07 12:27 PM Page 13-26
13SW
ITCHGEAR
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-27
For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.
Siemens / Speedfax Previous folio: 13-39
Protective Relays & SCADA SystemsSIPROTEC Protective Relays Selection
AN
SI N
um
ber
*
Protection Function 7SA
522
Dis
tan
ce
7SA
6
7SD
600
Pilo
t w
ire
dif
fere
nti
al
7SD
5Li
ne
dif
fere
nti
al
7SD
610
7SJ4
5O
verc
urr
ent
7SJ4
6
7SJ6
00
7SJ6
02
7SJ6
1
7SJ6
2
7SJ6
3
7SJ6
4
7VH
60D
iffe
ren
tial
7UT
612
7UT
613
7UT
63
7SS
60
7SS
52
7UM
61G
ener
ato
r an
d
7UM
62m
oto
r p
rote
ctio
n
7VK
61B
reak
er m
anag
emen
t
7VE
6S
ynch
ron
izin
g
7SV
600
Bre
aker
fai
lure
7RW
600
Vo
ltag
e, f
req
uen
cy
ANSI Selection List for Protective Relays
14 Locked rotor protection — — — — — — — — — ● ● ● ● — — — — — — ■ ■ — — — —
21 Distance protection, phase ■ ■ — ● — — — — — — — — — — — — — — — ■ ■ — — — —
21N Distance protection, earth (ground) ■ ■ — ● — — — — — — — — — — — — — — — — — — — — —
21FL Fault locator ■ ■ — ● — — — — — — ● ● ● — — — — — — — — — — — —
24 Overfluxing (V/f protection) — — — — — — — — — — — — — — — ● ● — — ■ ■ — — — ■
25 Synchronizing, synchronism check ● ● — ● — — — — — — — — ● — — — — — — — — ■ ■ — —
27 Undervoltage ● ● — ● — — — — — — ● ● ● — — — ● — — ■ ■ ● ● — ■
27/34 Stator earth-fault 3rd harmonic — — — — — — — — — — — — — — — — — — — ■ ■ — — — —
32 Directional power — — — — — — — — — — — — ● — — — ● — — — ■ — — — —
32F Forward power — — — — — — — — — — — — ● — — — — — — ● ■ — — — —
32R Reverse power — — — — — — — — — — — — ● — — — — — — ■ ■ — — — —
37 Undercurrent or underpower — — — — — — — — ● ■ ■ ■ ■ — — — — — — — ■ — — — —
40 Loss of field — — — — — — — — — — — — — — — — — — — ● ■ — — — —
46 Load unbalance, negative phase- — — — — — — — ■ ■ ■ ■ ■ ■ — ● — ● — — ● ● — — — —
sequence overcurrent
47 Phase-sequence voltage ■ ■ — ■ — — — — — — ■ ■ ■ — — — — — — ■ ■ — — — —
48 Incomplete sequence, locked rotor — — — — — — — — — — — — — — — — — — — ● ● — — — —
49 Thermal overload — ● — ■ ■ — — ■ ■ ■ ■ ■ ■ — ■ ■ ■ — — ■ ■ — — — —
49R Rotor thermal protection — — — — — — — ■ ■ ■ ■ ■ ■ — — — — — — — ■ — — — —
49S Stator thermal protection — — — — — — — ■ ■ ■ ■ ■ ■ — — — — — — ■ ■ — — — —
50 Instantaneous overcurrent ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ — ● ■ ■ ■ — — —
50N Instantaneous earth-fault ■ ■ — ■ ■ — — ■ ■ ■ ■ ■ ■ — ■ ■ ■ — ● ■ ■ — — — —
overcurrent
50BF Breaker failure ● ● — ■ ● — — — ■ ■ ■ ■ ■ — ● ● ● — ■ ■ ■ ■ — ■ —
51GN Zero speed and underspeed device — — — — — — — — — — — — — — — — — — — — ■ — — — —
51 Overcurrent-time relay, phase ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ — ● ■ ■ — — — —
51N Overcurrent-time relay, earth ■ ■ — ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ — ● ■ ■ — — — —
51V Overcurrent-time relay, — — — — — — — — — — — — — — — — — — — ■ ■ — — — —
voltage controlled
59 Overvoltage ● ● — ● — — — — — — ● ● ● — — — ● — — ■ ■ ● ● — ■
59N Residual voltage earth-fault ● ● — ● — — — — ■ — ■ ■ ■ — — — — — — ■ ■ — — — —
protection
59GN Stator earth-fault protection — — — — — — — — — — — — — — — — — — — ■ ■ — — — —
64 100% Stator earth-fault — — — — — — — — — — — — — — — — — — — — ● — — — —
protection (20 Hz)
64R Rotor earth-fault — — — — — — — — — — — — — — — — — — — ■ ■ — — — —
■ Standard function● Optional✽ ANSI/IEEE C37.2: IEEE Standard Electrical Power System Device Function Numbers
Sect_13_Speedfax2007 4/26/07 12:27 PM Page 13-27
13SW
ITCH
GEAR
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog13-28
For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.
Siemens / Speedfax Previous folio: 13-40
Protective Relays & SCADA SystemsSIPROTEC Protective Relays Selection
AN
SI N
um
ber
*
Protection Function 7SA
522
Dis
tan
ce
7SA
6
7SD
600
Pilo
t w
ire
dif
fere
nti
al
7SD
5Li
ne
dif
fere
nti
al
7SD
610
7SJ4
5O
verc
urr
ent
7SJ4
6
7SJ6
00
7SJ6
02
7SJ6
1
7SJ6
2
7SJ6
3
7SJ6
4
7VH
60D
iffe
ren
tial
7UT
612
7UT
613
7UT
63
7SS
60
7SS
52
7UM
61G
ener
ato
r an
d
7UM
62m
oto
r p
rote
ctio
n
7VK
61B
reak
er m
anag
emen
t
7VE
6S
ynch
ron
izin
g
7SV
600
Bre
aker
fai
lure
7RW
600
Vo
ltag
e, f
req
uen
cy
67 Directional overcurrent — — — — — — — — — — ■ ■ ■ — — — — — — ■ ■ — — — —
67N Directional earth-fault overcurrent ● ● — ● — — — — ■ — ■ ■ ■ — — — — — — ■ ■ — — — —
67G Stator earth-fault — — — — — — — — — — — — — — — — — — — ■ ■ — — — —
directional overcurrent
68 Power swing detection ● ● — ● — — — — — — — — — — — — — — — — ● — — — —
74TC Trip circuit supervision ■ ■ — ■ ■ — — ■ ■ ■ ■ ■ ■ — ● ● ● — — ■ ■ ■ — — —
78 Out-of-step protection — — — — — — — — — — — — — — — — — — — — ■ — — — —
79 Auto-reclosure ● ● — ● ● — — ● ● ● ● ● ● — — — — — — — — ■ — — —
81 Frequency protection ■ ■ — ● — — — — — — ● ● ● — — — ● — — ■ ■ — ● — ■
81R Rate-of-frequency-change protection — — — — — — — — — — — — — — — — — — — ● ● — ● — ●
Vector jump supervision — — — — — — — — — — — — — — — — — — — ● ● — ● — —
85 Carrier interface/remote trip ■ ■ ● ■ ■ — — — — — — — — — — — — — ■ — — — — — —
86 Lockout function ■ ■ ■ ■ ■ — — — — ■ ■ ■ ■ — ■ ■ ■ ■ — ■ ■ ■ ● — —
87G Differential protection generator — — — — — — — — — — — — — — ■ ■ ■ — — — ■ — — — —
87T Differential protection transformer — — ■ ● ● — — — — — — — — ■ ■ ■ ■ — — — ■ — — — —
87BB Differential protection busbar — — — — — — — — — — — — — — ■ ■ ■ ■ ■ — — — — — —
87M Differential protection motor — — — — — — — — — — — — — — ■ ■ ■ — — — ■ — — — —
87L Differential protection line — — ■ ■ ■ — — — — — — — — — ■ ■ ■ — — — — — — — —
87N Restricted earth-fault protection — — — — — — — — — ■ ■ ■ ■ ■ ● ● ● — — — ● — — — —
■ Standard function● Optional✽ ANSI/IEEE C37.2: IEEE Standard Electrical Power System Device Function Numbers
1) Only sensitive directional earth-fault overcurrent (67Ns).
1)
ANSI Selection List for Protective Relays
Sect_13_Speedfax2007 4/26/07 12:27 PM Page 13-28
13SW
ITCHGEAR
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-29
For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.
Siemens / Speedfax Previous folio: 13-41
Protective Relays & SCADA SystemsSIPROTEC Protective Relays Selection
Model Siemens Equivalent Typical Catalog Number
GE 239 SIMPRO SIMPRO-100-R-N
GE 269 SIMPRO SIMPRO-100-R-N
GE 269+ SIMPRO SIMPRO-100-R-N
GE 369 SIMPRO SIMPRO-100-R-V
GE 469 SIMPRO and 7SJ601 SIMPRO-100-R-V/7SJ6015-4EA01-0AA0
Motor Protection
Model Siemens Equivalent Typical Catalog Number
ABB CO (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase)7SJ46 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase)7SJ601 (1 three phase) 7SJ6015-4EA01-0AA0 (1 three phase)
ABB Microshield 7SJ600 7SJ6005-4EA00-0DA17SJ602 7SJ6025-4EB00-1FA07SJ61 7SJ6115-5EC90-1FA0+L0D7SJ62 7SJ6215-5EC90-1FE0+L0D
ABB DPU-1500 7SJ62 7SJ6215-5EC90-1FE0+L0D7SJ63 7SJ6315-5EC90-1FE0+L0D7SJ64 7SJ6405-5EC92-1FE4+L0D
ABB DPU-2000R 7SJ62 7SJ6215-5EC90-1FE0+L0D7SJ63 7SJ6315-5EC90-1FE0+L0D7SJ64 7SJ6405-5EC92-1FE4+L0D
Basler BE3-51 (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase)7SJ46 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase)
Basler BE1-51 (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase)7SJ46 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase)7SJ601 (1 three phase) 7SJ6015-4EA01-0AA0 (1 three phase)
Basler BE1-851 7SJ600 7SJ6005-4EA00-0DA17SJ602 7SJ6025-4EB00-1FA07SJ61 7SJ6115-5EC90-1FA0+L0D
Basler BE1-951 7SJ62 7SJ6215-5EC90-1FE0+L0D7SJ63 7SJ6315-5EC90-1FE0+L0D7SJ64 7SJ6405-5EC92-1FE4+L0D
GE MDP 7SJ45 7SJ4505-1EA00-1AA17SJ46 7SJ4605-1EA00-1AA07SJ601 7SJ6015-4EA01-0AA0
GE 735 7SJ600 7SJ6005-4EA00-0DA17SJ602 7SJ6025-4EB00-1FA07SJ61 7SJ6115-5EC90-1FA0+L0D
GE 750 7SJ62 7SJ6215-5EC90-1FE0+L0D7SJ63 7SJ6315-5EC90-1FE0+L0D7SJ64 7SJ6405-5EC92-1FE4+L0D
GE F60 7SJ62 7SJ6215-5EC90-1FE0+L0D7SJ63 7SJ6315-5EC90-1FE0+L0D7SJ64 7SJ6405-5EC92-1FE4+L0D
SEL 351A 7SJ62 7SJ6215-5EC90-1FE0+L0D7SJ63 7SJ6315-5EC90-1FE0+L0D7SJ64 7SJ6405-5EC92-1FE4+L0D
SEL 351 7SJ62 7SJ6215-5EC90-1FE0+L0D7SJ63 7SJ6315-5EC90-1FE0+L0D7SJ64 7SJ6405-5EC92-1FE4+L0D
SEL 351S 7SJ62 7SJ6215-5EC90-1FE0+L0D7SJ63 7SJ6315-5EC90-1FE0+L0D7SJ64 7SJ6405-5EC92-1FE4+L0D
SEL 501 7SJ600 7SJ6005-4EA00-0DA17SJ602 7SJ6025-4EB00-1FA07SJ61 7SJ6115-5EC90-1FA0+L0D
SEL 551 7SJ600 7SJ6005-4EA00-0DA17SJ602 7SJ6025-4EB00-1FA07SJ61 7SJ6115-5EC90-1FA0+L0D
Feeder Protection
Siemens Protective Relays - Quick Competitor Comparison by Application
*Siemens catalog numbers in Bold are the preferred equivalent model.
Siemens does not accept any liability for the information contained in this document.
Sect_13_Speedfax2007 4/26/07 12:27 PM Page 13-29
13SW
ITCH
GEAR
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog13-30
Siemens / Speedfax Previous folio: 13-42
Protective Relays & SCADA SystemsSIPROTEC Protective Relays Selection
Model Siemens Equivalent Typical Catalog Number
ABB GPU2000 7UM62 7UM6215-5EC90-0BA0+L0D
Basler BE1- GPS100 7UM61 7UM6115-5EC90-0CA0+L0D7UM62 7UM6215-5EC90-0BA0+L0D
Beckwith M-3420 7UM61 7UM6115-5EC90-0CA0+L0D7UM62 7UM6215-5EC90-0BA0+L0D
Beckwith M-3425 7UM62 7UM6215-5EC90-0CA0+L0D
GE 489 7UM61 7UM6115-5EC90-0CA0+L0D7UM62 7UM6215-5EC90-0BA0+L0D
SEL 300G 7UM61 7UM6115-5EC90-0CA0+L0D7UM62 7UM6215-5EC90-0BA0+L0D
General Protection
Model Siemens Equivalent Typical Catalog Number
Basler BE1-27 7RW600 7RW60000-4EA00-0DA0
Basler BE1-59 7RW600 7RW60000-4EA00-0DA0
Basler BE1-27/59 7RW600 7RW60000-4EA00-0DA0
Basler BE1-81O/U 7RW600 7RW60000-4EA00-0DA0
GE IAV 7RW600 7RW60000-4EA00-0DA0
GE IFV 7RW600 7RW60000-4EA00-0DA0
GE MIV 7RW600 7RW60000-4EA00-0DA0
GE NGV 7RW600 7RW60000-4EA00-0DA0
GE DFF 7RW600 7RW60000-4EA00-0DA0
GE MFF 7RW600 7RW60000-4EA00-0DA0
GE SFF 7RW600 7RW60000-4EA00-0DA0
Voltage/Frequency Protection
Model Siemens Equivalent Typical Catalog Number
ABB HU 7VH60 7VH6002-0EA20-0AA0
ABB CA 7VH60 7VH6002-0EA20-0AA0
ABB TPU2000R 7UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
Basler BE1-87 7UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0(3) 7VH60 7VH6002-0EA20-0AA0
GE PVD 7VH60 7VH6002-0EA20-0AA0
GE B30 7UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
SEL 387 7UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
Bus Protection
Model Siemens Equivalent Typical Catalog Number
ABB HU (3) 7UT512 (1) 7UT5125-4GB11-0AA07UT513 (1) 7UT5135-4GB11-1AA07UT612 (1) 7UT6125-5EC00-1AA0
ABB CA (3) 7UT512 (1) 7UT5125-4GB11-0AA07UT513 (1) 7UT5135-4GB11-1AA07UT612 (1) 7UT6125-5EC00-1AA0
ABB TPU2000R 7UT512 7UT5125-4GB11-0AA07UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
Basler BE1-CDS 7UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
GE 745 7UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
GE T60 7UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
SEL 387 7UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
SEL 587 7UT512 7UT5125-4GB11-0AA07UT513 7UT5135-4GB11-1AA07UT612 7UT6125-5EC00-1AA0
Transformer Protection
*Siemens catalog numbers in Bold are the preferred equivalent model.
Sect_13_Speedfax2007 4/26/07 12:27 PM Page 13-30