BONE HEALTH SOLUTIONS Hologic pioneered dual x-ray (DXA) bone densitometry technology which has become the industry standard for assessing bone health and osteoporosis risk. Today, using the Discovery™ system, clinicians can identify fractures not discernible by physical examination, while determining basic bone mineral density and the patient’s T-score. The system also offers several other impressive applications such as High Definition Instant Vertebral Assessment™ (IVA™-HD) which provides a high resolution image for assessing vertebral fractures while also providing visualization of the abdominal aorta for evaluating calcifications (AAC), FRAX ® fracture risk assessment, and Advanced Body Composition™ assessment with InnerCore™ visceral fat assessment which affords the clinical practitioner an overview of fat mass, lean mass, and visceral fat all of which could be key indicators for cardiovascular risk and other metabolic disease states. www.hologic.com Discovery DXA System Advanced Health Assessment BONE HEALTH SOLUTIONS

Upload: others

Post on 19-Mar-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Discovery DXA System Advanced Health Assessment · 2020. 7. 2. · Hologic pioneered dual x-ray (DXA) bone densitometry technology which has become the industry standard for assessing

B O N E H E A L T H s O L u T i O N s

Hologic pioneered dual x-ray (DXA) bone densitometry technology which has become the industry

standard for assessing bone health and osteoporosis risk. Today, using the Discovery™ system,

clinicians can identify fractures not discernible by physical examination, while determining basic

bone mineral density and the patient’s T-score. The system also offers several other impressive

applications such as High Definition Instant Vertebral Assessment™ (IVA™-HD) which provides

a high resolution image for assessing vertebral fractures while also providing visualization of

the abdominal aorta for evaluating calcifications (AAC), FRAX® fracture risk assessment, and

Advanced Body Composition™ assessment with InnerCore™ visceral fat assessment which

affords the clinical practitioner an overview of fat mass, lean mass, and visceral fat all of which

could be key indicators for cardiovascular risk and other metabolic disease states.

www.hologic.com

Discovery™ DXA SystemAdvanced Health Assessment

B O N E H E A L T H s O L u T i O N s

Page 2: Discovery DXA System Advanced Health Assessment · 2020. 7. 2. · Hologic pioneered dual x-ray (DXA) bone densitometry technology which has become the industry standard for assessing

Patient Weight Limit450 lbs

Typical Exposure TimeLumbar spine & femur ... 10 sec / 0.04 mGy (A, SL, W, C models)

IVA™-HD ..................... 15 sec / 0.025 mGy

Whole body .................. 174 sec / 0.007 mGy (A model) 272 sec / 0.015 mGy (PW, Wi, W models)

Standard Computer Hardware (Minimum Configuration)Computer worktable with Dual Core 3 GHz

Windows® 7XP Professional 32 bits

250 GB hard drive

2 GB RAM

17" LCD flat panel monitor

HP color InkJet® printer

DVD RAM drive

Network ready

Optional HardwareHP color LaserJet® printer

Oasis stand-alone workstation

Standard Software ConfigurationAPEX™ operating system

FRAX® World Health Organization 10-Year Fracture Risk Assessment

Express BMD (not available on P or -i models)

Tech Tips™

Express Exam™ protocol grouping program

AccuView™ hip positioning

ProTech with DXApro

OneTime™ auto analysis

NHANES body composition reference data (PW, Wi, W and A models)

BMDCS pediatric reference data for spine, hip, forearm and whole body

QDR® OnePage™ report

ISCD compliant reporting software

Context sensitive help

Colored fracture risk indication report

Auto low BMD analysis for spine and hip

Scan/Analyze protocols for AP lumbar spine, proximal femur, Dual Hip™ software, forearm, and scoliotic spine, pediatric spine, hip, and forearm

Advanced Body Composition™ assessment and subregion analysis (PW, Wi, W and A models)

InnerCore™ visceral fat assessment (PW, Wi, W and A models)

Physicians Viewer™ software with MXApro™ computer aided fracture assessment tool

Serial examination trending with facility specific LSC

Optional SoftwarePhysicians Report Writer™ DX

IRIS™ enterprise connectivity suite*

DB Sync™ database synchronizer

Scanning MethodLinear X-ray fan-beam, utilizing motorized table and C-arm

X-ray SystemSwitched-pulse dual-energy (100 kVp/140 kVp)

Detector SystemMulti-element high resolution digital detector array

External ShieldingNone required**

BMD Precision<1.0%

Scan Region38" x 20" (77" x 26" on whole body models)

Table Height28"

CalibrationAutomatic, continuous calibration using Hologic’s automatic internal reference system. Operator calibration not required

Automatic quality control program with multiple system checks

Operating RequirementsTemperature: 60° - 90°F (15°-32°C)

Power: 100 VAC (16 A); 120 VAC (14 A); 230 VAC (8 A)

Humidity: 20% - 80% relative humidity, noncondensing

Average heat load: 3,400 BTU/hr

     NOTE: Features and specifications subject to change without notice

*Some components of the IRIS package can be purchased separately.

** I nstallation requirements for x-ray equipment vary. Check with local regulatory authorities.

Product Specifications

Discovery™ DXA System

Page 3: Discovery DXA System Advanced Health Assessment · 2020. 7. 2. · Hologic pioneered dual x-ray (DXA) bone densitometry technology which has become the industry standard for assessing

Discovery™ Ci Discovery Wi Discovery P Discovery PW Discovery C Discovery W Discovery SL Discovery A

64 Detectors 64 Detectors 64 Detectors 64 Detectors 128 Detectors 128 Detectors 128 Detectors 216 Detectors

Regional Scans 30 s

Regional Scans 30 s

Regional Scans 30 s

Regional Scans 30 s

Regional Scans 10 s

Regional Scans 10 s

Regional Scans 10 s

Regional Scans 10 s

Supine Lateral BMD

Supine Lateral BMD

IVA™ w/AAC IVA w/AAC IVA-HD w/AAC IVA-HD w/AAC IVA-HD w/AAC IVA-HD w/AAC

Advanced Body Composition™ Assessment and

Subregion Analysis

Advanced Body Composition

Assessment and Subregion Analysis

Advanced Body Composition

Assessment and Subregion Analysis

Advanced Body Composition

Assessment and Subregion Analysis

Forearm Forearm Forearm Forearm Forearm Forearm Forearm Forearm

Dual Hip Dual Hip Dual Hip Dual Hip Dual Hip Dual Hip Dual Hip Dual Hip

Proximal Femur Proximal Femur Proximal Femur Proximal Femur Proximal Femur Proximal Femur Proximal Femur Proximal Femur

Lumbar Spine Lumbar Spine Lumbar Spine Lumbar Spine Lumbar Spine Lumbar Spine Lumbar Spine Lumbar Spine

Hip Structure Analysis

Hip Structure Analysis

Hip Structure Analysis

Hip Structure Analysis

Hip Structure Analysis

Hip Structure Analysis

Hip Structure Analysis

Hip Structure Analysis

Decubitus Lateral BMD

Decubitus Lateral BMD

Decubitus Lateral BMD

Decubitus Lateral BMD

Decubitus Lateral BMD

Decubitus Lateral BMD

www.hologic.com

Scan Site Specifications According to Model

Research Option Package

Prosthetic Hip

Small Animal

Infant Body Composition Assessment and Subregion Analysis

(only on PW, W and A systems)

Page 4: Discovery DXA System Advanced Health Assessment · 2020. 7. 2. · Hologic pioneered dual x-ray (DXA) bone densitometry technology which has become the industry standard for assessing

United States / Latin America

35 Crosby Drive Bedford, MA 01730-1401 USA Tel: +1.781.999.7300 Fax: +1.781.280.0668 www.hologic.com

Europe

Everest (Cross Point) Leuvensesteenweg 250A 1800 Vilvoorde Belgium Tel: +32.2.711.4680 Fax: +32.2.725.2087

Asia Pacific

7th Floor, Biotech Centre 2 No. 11 Science Park West Avenue Hong Kong Science Park Hong Kong Tel: +852.3748.7700 Fax: +852.3526.0723

S-161 US Only (07/12) © Hologic 2012. All rights reserved. Printed in USA. Specifications are subject to change without prior notice. Hologic, the Hologic logo, AccuView, Advanced Body Composition, APEX, DB Sync, Discovery, Dual Hip, Express Exam, InnerCore, Instant Vertebral Assessment, IRIS, IVA, MXApro, OnePage, OneTime, Physicians Report Writer, Physicians Viewer, QDR and Tech Tips are trademarks and/or registered trademarks of Hologic and/or Hologic subsidiaries, in the United States and/or other countries. All other trademarks and registered trademarks are the property of their respective owners.

The Discovery™ DXA system packs a lot of performance into a small footprint. Operating from existing dedicated power sources, the system fits comfortably in an 8' x 8' exam room (8' x 10' for whole body models) and require no protective shielding or special room preparations.*

*Installation requirements for x-ray equipment vary. Check with local regulatory authorities.

Australia /New Zealand

Suite 402, Level 4 2 Lyon Park Road Macquarie Park NSW 2113 Australia Tel: +61.2.9888.8000 Fax: +61.2.9870.7555