Bulletin 1600 Air-Cooled Fluid Coolers Direct Drive Remote Air-Cooled Fluid Coolers 33 Models Model AFV with Vertical Air Discharge Also available in AFH Models with Horizontal Discharge “The Heat Transfer Experts”

Upload: others

Post on 17-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Bulletin 1600 Air-Cooled Fluid Coolers

Direct Drive Remote Air-Cooled Fluid Coolers

33 Models

Model AFV with Vertical Air Discharge Also available in AFH Models with Horizontal Discharge

“The Heat Transfer Experts”

Page 2: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 2

TABLE OF CONTENTS

FIGURES TABLES PAGE

Features and Options ..................................................................................................................................................... 3Nomenclature .............................................................................................................................................................. 3Specifications

Physical Specifications ........................................................................................................ Table 1 ...................... 4Electrical Specifications ...................................................................................................... Table 2 ....................... 5Dimensions, Models 62 thru 384......................................................... Fig 1 ........................................................... 6Dimensions, Models 119 thru 636....................................................... Fig 2 ........................................................... 7Dimensions, Models 714 thru 1271 .................................................... Fig 3 ........................................................... 8Dimensions, Models 1425 thru 1625. ................................................. Fig 4 ........................................................... 9

50 Hz Operation .................................................................................................................. Table 3 ..................... 10Fan Speed/Sound Level ...................................................................................................... Table 4 ..................... 10

Selection ProcedureGlossary of Terms .................................................................................................................................................. 11Selection Example.................................................................................................................................................. 12Notes ............................................................................................................................................................ 13Suggested Connection Sizes based on GPM ..................................................................... Table 5 ..................... 13Optional Fan Control .............................................................................................................................................. 13Fluid Heat Factors ............................................................................... Fig 5 ......................................................... 14Capacity Correction Factors ................................................................ Fig 6 ......................................................... 14Fluid Pressure Drop ............................................................................ Fig 7 ......................................................... 15Pressure Drop Correction Factors ...................................................... Fig 8 ......................................................... 16Altitude Correction Factor ................................................................... Fig 9 ......................................................... 16(1) Fan Fluid Coolers........................................................................... Fig 10 ....................................................... 17(2) Fan Fluid Coolers........................................................................... Fig 11 ....................................................... 18(3) Fan Fluid Coolers........................................................................... Fig 12 ....................................................... 19(4) Fan Fluid Coolers........................................................................... Fig 13 ....................................................... 20(5) & (6) Fan Fluid Coolers .................................................................. Fig 14 ....................................................... 21(8) Fan Fluid Coolers........................................................................... Fig 15 ....................................................... 22(10) Fan Fluid Coolers ........................................................................ Fig 16 ....................................................... 23

Page 3: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 3

STANDARD FEATURES:

Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water andPropylene Glycol/Water mixtures in a variety of closed-loop applications. Closed-loop cooling eliminates the cost of fluidtreatment usually associated with the use of cooling towers.

• Wide range of models and capacities - 33 models.

• Corrosion resistant construction - Mill galvanized housing, powder coated steel fan guards, aluminum fan bladeson 3/4 Hp models, galvanized steel fan blades on 1 & 2 Hp models. Low speed, fully guarded fans for quietoperation.

• Built-in lifting eyes, and easy-to-install legs, make rigging and installation fast.

• Low noise, 850 RPM fans, on 1 & 2 Hp models.

• Compartmented fans to prevent short circuiting of air during fan cycling.

• Units designed for efficient fan cycle control.

• Versatile cabinet design for vertical or horizontal airflow.

• Coil is made of 1/2" dia seamless copper tubes,and high efficiency aluminum plate fins, with self-spacing collars.

• Exclusive Colmac “Full Floating Core” coil support system eliminates tubesheet leaks by shifting support of thecoil core from tubes to fins. Special “Wear Guards” allow expansion and contraction of fins and tubes withoutchafing or wearing of tubes, or fins.

• Heavy duty rigid foot-mounted direct drive fan motors with moisture protected rainshields (slingers) are internallyprotected single or three phase on models 62 thru 384 (3/4 Hp), internally protected three phase only on models119 thru 1271 (1 Hp), and three phase externally protected only on models 1425 thru 1625 (2 Hp). Motors are ratedfor 150°F maximum air temperature over the motor.

• Weatherproof electrical enclosure features single point field wiring, and is easily accessible for fast installation.

OPTIONS:

• Copper fins, or Polycoat Fins for corrosion resistance. • Baked phenolic coating available

• Stainless or galvanized steel fan blades or cast aluminum. • UL 508 listed electrical panels

• Stainless steel housing. • CSA listing available

• Factory mounted and wired fused disconnect.

• Factory wired fan cycle/fan speed control.

• Customer specified control systems.

AF VOLTAGE CODE:Air Cooled Fluid Cooler

V A - 208-230/60/1V - Vertical Air Discharge B - 208-230/60/3H - Horizontal Air Discharge C - 460/60/1

D - 460/60/3E - 575/60/3

Model Number F - 380/60/3G - 220-240/50/1H - 200/50/3

NOMENCLATURE: AF V - 763 - D

Page 4: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 4

TABLE 1AFV/AFH PHYSICAL SPECIFICATIONS

Wt. (lbs.) of 40% Glycol Fan No. Coil Rows Fins/ Internal Mixture @ 135°F Dry Wt.

Model Dia. in. Fans CFM Face Deep Inch Vol. Cu/Ft. Ethel. Propyl. lbs.

62 24 1 6310 35 x 48 2 14 0.324 21.0 20.5 33084 24 1 6039 35 x 48 3 14 0.487 31.5 30.8 35796 24 1 5734 35 x 48 4 14 0.649 42.0 41.1 383167 24 2 12078 35 x 96 3 14 0.936 60.6 59.3 589192 24 2 11468 35 x 96 4 14 1.25 80.9 79.1 643251 24 3 18117 35 x 144 3 14 1.39 90.0 88.0 863288 24 3 17202 35 x 144 4 14 1.85 119.8 117.1 944307 24 4 24800 35 x 192 3 11 1.84 119.1 116.5 1056335 24 4 24156 35 x 192 3 14 1.84 119.1 116.5 1096384 24 4 22936 35 x 192 4 14 2.45 158.6 155.1 1203

119 30 1 8620 45 x 54 3 14 0.698 45.2 44.2 513127 30 1 8090 45 x 54 4 14 0.931 60.3 58.9 552223 30 2 18060 45 x 108 3 11 1.35 87.4 85.5 815238 30 2 17240 45 x 108 3 14 1.35 87.4 85.5 843254 30 2 16180 45 x 108 4 14 1.80 116.5 114.0 921357 30 3 25860 45 x 162 3 14 2.00 129.5 126.6 1242381 30 3 24270 45 x 162 4 14 2.66 172.2 168.4 1358446 30 4 36120 45 x 216 3 11 2.65 171.5 167.8 1516476 30 4 34480 45 x 216 3 14 2.65 171.5 167.8 1572509 30 4 32360 45 x 216 4 14 3.53 228.5 223.5 1728595 30 5 43100 45 x 270 3 14 3.30 213.6 208.9 1971636 30 5 40450 45 x 270 4 14 4.40 284.8 278.6 2165

714 30 6 51720 90 x 162 3 14 4.00 258.9 253.2 2374763 30 6 48540 90 x 162 4 14 5.32 344.4 336.8 2607893 30 8 72240 90 x 216 3 11 5.30 343.1 335.5 2927952 30 8 68960 90 x 216 3 14 5.30 343.1 335.5 30401017 30 8 64720 90 x 216 4 14 7.06 457.0 447.0 33511116 30 10 90300 90 x 270 3 11 6.60 427.2 417.8 36611190 30 10 86200 90 x 270 3 14 6.60 427.2 417.8 38031271 30 10 80900 90 x 270 4 14 8.80 569.6 557.1 4191

1425 36 10 111900 90 x 270 3 14 6.60 427.2 417.8 43681502 36 10 101600 90 x 270 4 14 8.80 569.6 557.1 47561625 36 10 88000 90 x 270 6 14 13.20 854.4 835.7 5532

Notes: 1. Weight of Liquid is calculated as follows:

Wt. Liquid (lbs) = Internal Vol. (cu. ft.) x Liquid Density(lbs/cu ft)

2. Operating Weight = Dry Weight + Weight Liquid

3. Units having finned length up to 216" use 1/2 x 0.016 copper tubes.Units having finned length of 270" use 1/2 x 0.025 copper tubes.

Page 5: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 5

TABLE 2AFV/AFH ELECTRICAL SPECIFICATIONS

Total FLA/60 Hz Supply Total FLA/50 Hz SupplyModel Fan No. Fan Note 3

dia,in. Fan Hp 208-230/1 208-230/3 460/1 460/3 200/3 400/3

62 24 1 3/4 3.9 3.40 1.9 1.55 4.2 2.1 84 24 1 3/4 3.9 3.40 1.9 1.55 4.2 2.1 96 24 1 3/4 3.9 3.40 1.9 1.55 4.2 2.1167 24 2 3/4 7.8 6.80 3.8 3.10 8.4 4.2192 24 2 3/4 7.8 6.80 3.8 3.10 8.4 4.2251 24 3 3/4 11.7 10.20 5.7 4.65 12.6 6.3288 24 3 3/4 11.7 10.20 5.7 4.65 12.6 6.3307 24 4 3/4 15.6 13.60 7.6 6.20 16.8 8.4335 24 4 3/4 15.6 13.60 7.6 6.20 16.8 8.4384 24 4 3/4 15.6 13.60 7.6 6.20 16.8 8.4

119 30 1 1 note 1 5.6 note 1 2.8 4.2 2.1127 30 1 1 ” 5.6 ” 2.8 4.2 2.1223 30 2 1 ” 11.2 ” 5.6 8.4 4.2238 30 2 1 ” 11.2 ” 5.6 8.4 4.2254 30 2 1 ” 11.2 ” 5.6 8.4 4.2357 30 3 1 ” 16.8 ” 8.4 12.6 6.3381 30 3 1 ” 16.8 ” 8.4 12.6 6.3446 30 4 1 ” 22.4 ” 11.2 16.8 8.4476 30 4 1 ” 22.4 ” 11.2 16.8 8.4509 30 4 1 ” 22.4 ” 11.2 16.8 8.4595 30 5 1 ” 28.0 ” 14.0 21.0 10.5636 30 5 1 ” 28.0 ” 14.0 21.0 10.5

714 30 6 1 note 1 33.6 note 1 16.8 25.2 12.6763 30 6 1 ” 33.6 ” 16.8 25.2 12.6893 30 8 1 ” 44.8 ” 22.4 33.6 16.8952 30 8 1 ” 44.8 ” 22.4 33.6 16.81017 30 8 1 ” 44.8 ” 22.4 33.6 16.81116 30 10 1 ” 56.0 ” 28.0 42.0 21.01190 30 10 1 ” 56.0 ” 28.0 42.0 21.01271 30 10 1 ” 56.0 ” 28.0 42.0 21.0

1425 36 10 2 note 1 86.0 note 1 43.0 93.7 46.91502 36 10 2 ” 86.0 ” 43.0 93.7 46.91625 36 10 2 ” 86.0 ” 43.0 93.7 46.9

Notes:1. These units not available for single phase supply.

2. Models 62 through 384 (24” Fans)Standard motors are 3/4 HP, 1140 RPM ODP, 60 Hz with internal thermal overload protection.

Models 119 through 1271 (30” Fans)Standard motors are 1 HP, 850 RPM ODP, 60 Hz with internal thermal overload protection.

Models 1425 through 1625 (36” Fans)Standard motors are 2 HP, 850 RPM TEFC, 60 Hz without internal thermal overload protection.

3. For 50 Hz operation: 1 HP motors are used in lieu of 3/4 HP.(see Page 10) 1-1/2 HP motors are used in lieu of 1 HP.

2 HP motors are 950 RPM, 2 HP.

Page 6: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 6

FIGURE 1PHYSICAL DIMENSIONS, Models 62 thru 384

(24" dia fans)

DIMENSIONS

MAX. INLET/OUTLETMODEL NO. FANS A B C D E CONN. SIZE, MPT

62 1 48 46 - 4 4 384 1 48 46 - 4 4 396 1 48 46 - 4 4 3167 2 96 94 - 4 4 3192 2 96 94 - 4 4 4251 3 144 94 48 6 6 4288 3 144 94 48 6 6 4307 4 192 94 96 6 6 4335 4 192 94 96 6 6 4384 4 192 94 96 6 6 4

FLO

WA

IR

AIRFLOW

16 9/16"

B C

40 1/2"

39 3/4"

30"

12"

5/8 DIA MTG HOLE

LIFTING EYE

INLET

OUTLET

A

CB28 5/8"

A

39 1/4"

26 1/8"

ELECTRICALENCLOSURE

(E) PLCS

(D) PLCS

AFV, VERTICAL AIRFLOW

AFH, HORIZONTAL AIRFLOW

OUTLETINLET

LIFTING EYE(D) PLCS

12"

INLET

OUTLET

5/8 DIA MTG HOLE(E) PLCS

ELECTRICALENCLOSURE

(SEE NOTE 3.)

NOTES:

1. Fan Diameter is 24”.2. 60Hz Fan Speed is 1140 RPM.3. Adjustable in 6” increments to 40-9/16.

Page 7: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 7

DIMENSIONS

MAX. INLET/OUTLETMODEL NO. FANS A B C D E F CONN. SIZE, MPT

119 1 54 50 1/2 - - 4 4 4127 1 54 50 1/2 - - 4 4 4223 2 108 104 1/2 - - 4 4 4238 2 108 104 1/2 - - 4 4 4254 2 108 104 1/2 - - 4 4 4357 3 162 104 1/2 - 54 6 6 4381 3 162 104 1/2 - 54 6 6 4446 4 216 104 1/2 - 108 6 6 4476 4 216 104 1/2 - 108 6 6 4509 4 216 104 1/2 - 108 6 6 4595 5 270 104 1/2 57 1/2 104 1/2 8 8 4636 5 270 104 1/2 57 1/2 104 1/2 8 8 4

AIRFLOW

FLO

WA

IR

26"

30 1/4"A

A

D C B

ELECTRICAL

OUTLETINLET

LIFTING EYE

5/8 DIA MTG HOLE

12"

37 3/4"

49 5/8"

48 5/8"

BCD

22 5/8"

AFH, HORIZONTAL AIRFLOW

(E) PLCS

ENCLOSURE(E) PLCS

(F) PLCSAFV, VERTICAL AIRFLOW

OUTLETINLET

LIFTING EYE

12"

INLET

OUTLET

ELECTRICAL

5/8 DIA MTG HOLE

ENCLOSURE

(F) PLCS

49 5/8"

(SEE NOTE 3.)

NOTES:

1. Fan Diameter is 30”.2. 60Hz Fan Speed is 850 RPM.

Single Phase Motors Not Available.3. Adjustable in 7-9/16 increments

to 37-3/4.

FIGURE 2PHYSICAL DIMENSIONS, Models 119 thru 636

(30" dia fans)

Page 8: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 8

FIGURE 3PHYSICAL DIMENSIONS, Models 714 thru 1271

(30" dia fans)

MAX. INLET/OUTLETMODEL NO. FANS A B C D E F CONN. SIZES, MPT

714 6 162 104 1/2 - 54 6 6 5763 6 162 104 1/2 - 54 6 6 6893 8 216 104 1/2 - 108 6 6 5952 8 216 104 1/2 - 108 6 6 51017 8 216 104 1/2 - 108 6 6 61116 10 270 104 1/2 57 1/2 104 1/2 8 8 51190 10 270 104 1/2 57 1/2 104 1/2 8 8 51271 10 270 104 1/2 57 1/2 104 1/2 8 8 6

DIMENSIONS

AIR

FLO

W

FLOWAIR

FLOWAIR

A

BCD

30 1/8"

82 7/8"

62 1/8"

94 7/8"

12"

5/8 DIA MTG HOLE

LIFTING EYE

INLETOUTLET

ELECTRICALENCLOSURE

ENCLOSUREELECTRICAL

94 7/8"

5/8 DIA MTG HOLE

30 1/4"

26"

AFV, VERTICAL AIRFLOW (F) PLCS

(E) PLCS

(E) PLCS

AFH, HORIZONTAL AIRFLOW(F) PLCS

AIR

FLO

W

OUTLETINLET

12"

LIFTING EYEBCD

A

OUTLET

INLET

(SEE NOTE 3.)

NOTES:

1. Fan Diameter is 30”.2. 60Hz Fan Speed is 850 RPM.

Single Phase Motors Not Available.3. Adjustable in 7-9/16 increments

to 45-1/4.

Page 9: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 9

FIGURE 4PHYSICAL DIMENSIONS, Models 1425 thru 1625

(36" dia fans)

MAX. INLET/OUTLETMODEL NO. FANS A B C D E F CONN. SIZES, MPT

1425 10 270 104 1/4 57 3/4 104 1/4 8 8 51502 10 270 104 1/4 57 3/4 104 1/4 8 8 61625 10 270 104 1/4 57 3/4 104 1/4 8 8 6

DIMENSIONS

AIR

FLO

W

AIR

FLO

W

FLOWAIR

FLOWAIR

A

BCD

30 1/8"

82 7/8"

61 1/2"

94 7/8"

12"

5/8 DIA MTG HOLE

LIFTING EYE

INLETOUTLET

ELECTRICALENCLOSURE

94 7/8"

35"

AFV, VERTICAL AIRFLOW (F) PLCS

(E) PLCS

AFH, HORIZONTAL AIRFLOW

OUTLETINLET

LIFTING EYE(E) PLCS

12"

BCD

A

ELECTRICALENCLOSURE

2” DIA MTG HOLE(F) PLCS

OUTLET

INLET

(SEE NOTE 3.)

30 3/4"

NOTES:

1. Fan Diameter is 36”.2. 60Hz Fan Speed is 850 RPM.

Single Phase Motors Not Available.3. Adjustable in 7” increments to 44-1/8.

Page 10: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 10

OPERATION WITH 50 Hz POWER

COLMAC AFV and AFH fluid coolers are designed to operate with either 60 Hz, or 50 Hz supply power. Cooling capacityfor 50 Hz operation will be the same as capacity for 60 Hz operation, since COLMAC uses fan blades matched to the 50Hz rotational speed of 950 RPM.

Motor horsepower on most models will be different, however. The 60 Hz, 3/4 HP motors will be replaced with 1.0 HP motors,and 60 Hz, 1.0 HP motors will be replaced with 1.5 HP motors for 50 Hz operation.

50 Hz FAN SPEED/SOUND LEVEL:

Operation of fluid coolers at 50 Hz will change the rotational speed of the fans. All fans will turn at 950 RPM. The 24 in.dia. fans will turn slower than those used for 60 Hz operation, and will run quieter. The 30 and 36 in. dia. fans will turn fasterthan those used for 60 Hz operation and will be somewhat louder. Fan and tip speeds, and sound levels for 60 Hz and 50Hz are shown in tables 3 and 4.

TABLE 3FAN SPEEDS

60 Hz 50 HzFan Fan Tip Spd Fan Tip Spd

Models Dia RPM FPM RPM FPM

62 thru 384 24" 1140 7163 950 5969 119 thru 1271 30" 850 6676 950 74641425 thru 1625 36" 850 8011 950 8958

TABLE 4AFV/AFH SOUND LEVELS (Approx.)*

60 Hz Operation 50 Hz OperationdBA @ Distance from Unit, Ft dBA @ Distance from Unit, Ft

No. Fans 5’ 25’ 50’ 100’ 5’ 25’ 50’ 100’

24 dia1 70 56 50 44 66 52 46 402 73 59 53 47 69 55 49 433 75 61 55 49 71 57 51 454 76 62 56 50 72 58 52 46

30 dia1 69 55 49 43 71 57 51 452 72 58 52 46 74 60 54 483 74 60 54 48 76 62 56 504 75 61 55 49 77 63 57 515 76 62 56 50 78 64 58 526 77 63 57 51 79 65 59 538 78 64 58 52 80 66 60 5410 79 65 59 53 81 67 61 55

36 dia10 85 71 65 59 87 73 67 61

*Based on free field sound data, with no background noise.

Page 11: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 11

SELECTION PROCEDURE:

The selection of a COLMAC AFV/AFH fluid cooler is mostly graphical and is easy to make.

Glossary of Terms

ACF = Altitude Correction Factor (Fig. 9)CCF = Capacity Corr. Factor, Fluid Mixture (Fig. 6)EAT = Entering Air Temp.EFT = Entering Fluid Temp.FF = Flow factor (Figs. 10 thru 16)FHF = Fluid Heat Factor (Fig. 5)GPM = Gallons per MinuteLAT = Leaving Air Temp.LFT = Leaving Fluid Temp.LF = Length factor (Figs. 10 thru 16)MBH = BTUH x 1000ΔPfluid= Fluid Pressure Drop, psi (Fig. 7)PDF = Pressure Drop Factor (Fig. 8)

Step 1. Calculate Avg Fluid Temp., AFT.AFT = (EFT + LFT) / 2

Step 2. Calculate Fluid ΔT.ΔT = EFT - LFT

Step 3. Calculate temperature difference, TDTD = EFT - EAT

Step 4. Find Fluid Heat Factor, FHF, (Fig. 5).

Step 5. Calculate MBH required per degree of temperature difference.MBH / TD = (GPM x ΔT x FHF) / TD

Step 6. Correct MBH / TD with CCF (Fig. 6) and ACF (Fig. 9).MBH / TD = (MBH / TD) x CCF x ACF

Step 7. Choose Model, using GPM and MBH / TD in Figs. 10 thru 16. ** (Use Models whose performance curves fall on, or above MBH / TD)

Step 8. Find Fluid Pressure Drop:- Using GPM, find FF and LF from Figure used in step 7.- Using FF and LF, go to Fig. 7, to find ΔPfluid.

Step 9. Correct Fluid Pressure Drop with PDF (Fig. 8).ΔPfluid = ΔPfluid x PDF

Step 10. (Optional) Unit capacity can be approximated by the following method:

MBH/TD (Curve value) MBH actual = ————————————————————— x TD CCF x ACF

Page 12: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 12

EXAMPLE

1. AFT = (125 + 115.5) / 2AFT = 120.3°F Given: % Glycol = 30% Ethylene Glycol

GPM = 802. ΔT = 125 - 115.5 EFT = 125°F

ΔT = 9.5°F LFT = 115.5°FEAT = 95°F

3. TD = 125 - 95 Alt.= 2,000 ftTD = 30°F

4. From Fig. 5, we see that FHF = 0.466

5. Calculate MBH / TD = (GPM x ΔT x FHF) / TDMBH/TD = (80 x 9.5 x 0.466) / 30MBH/TD = 11.8

6. Correcting capacity for 30% Eth. Gly. and 2,000 ft alt.using CCF (Fig. 6) and ACF (Fig. 9):

CCF = 1.002 and ACF = 1.04

MBH/TD = 11.8 x 1.002 x 1.04MBH/TD = 12.3

7. Looking at Fig. 11, using 80 GPM and 12.3 MBH/TD:

a. Choose AFV-254 At 80 GPM, it’s performance is 12.9 MBH/TD, which is greater than 12.3

b. Using diagrams in Fig. 11 for Flow Factor (above) and Length Factor, (side):for AFV-254 (Fig. 11): FF = 3.33

LF = 648

8. Looking at Fig. 7, using 80 GPM, FF = 3.33 and LF = 648

ΔPfluid = 7.5

9. Correct for ΔPfluid for 30% Eth. Gly mixture at 120°f using Fig. 8: PDF = 1.175

ΔPfluid = ΔPfluid x PDFΔPfluid = 1.175 x 7.5

ΔPfluid = 8.8 psi

10. Actual Unit Capacity at 80 GPM, 120°F AFT, 30°TD, and 30% Ethylene glycol, is approximately:

MBH / TD 12.9 MBH/ T̄D MBH actual = ————————————— x TD = ——————————————— x 30

CCF X ACF 1.002 x 1.04

MBH actual = 371.37

Page 13: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 13

Notes:

1. The selection procedure is optimized for system performance while keeping fluid pressure drops below a reasonablemaximum (less than 12 PSI). If calculated ΔPfluid is greater than that desired, it is possible to make another selectionon COLMAC’s CoilPRO III software, using a “Hot Water/Sensible Cooling” coil, or have COLMAC’s Factory Salespeople assist in making another circuiting selection.

2. Flow Factors greater than 3.5 are not recommended, and are not represented in Figs. 10 thru 16.

3. See Table 5. for suggested inlet/outlet pipe sizing.

TABLE 5.

Gallons Per Suggested Inlet/Outlet * Based on mean head Minute Connection Size, MPT loss of 2.5ft / 100ft,

ASHRAE Fundamentals 2 - 6 1" Handbook, 1993 7 - 12 1 1/4 13 - 20 1 1/2 21 - 40 2" 41 - 80 2 1/2 81 - 120 3"121 - 260 4"261 - 700 6"

OPTIONAL FAN CONTROL

COLMAC offers FC Fan Cycling and MS Modulated Speed control packages to compliment the selection of any fluid cooler.Such controls may be used to maintain the desired Leaving Fluid Temperature regardless of operating conditions, orseasons.

FC fan cycling controls will stop rotation of one or more fans in incremental stages to maintain temperature.

MS controls will slow rotation of one or more fans to maintain temperature. On multiple fan models, a combination ofModulation and Cycling is used. If the fluid temperature falls below the point at which the Modulating fan(s) can maintaintemperature, one or more additional fans will be shut off and the remaining Modulating fans will gain more speed until thedesired fluid temperature is reached.

Note: Because MS controls affect motor winding temperature, please consult the Factory for application information andpricing.

Page 14: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 14

FIGURE 5

FLUID HEAT FACTORS, FHF

P.G.10%P.G.20%P.G.30%

P.G.40%

P.G.50%

WATERE.G.10%E.G.20%E.G.30%

E.G.40%

E.G.50%

1.16

1.14

1.12

1.10 WATER & ETHYLENE GLYCOL

CC

F

0.94

0.96

1.08

1.06

1.04

1.02

1.00

0.98

0.96

AVG. FLUID TEMP °F

WATER & PROPYLENE GLYCOL

180170160150140130120110100 100 110 120 130 140 150 160 170 180

AVG. FLUID TEMP °F

0.98

1.00

1.02

1.04

1.06

1.08

0.95

0.97

0.99

1.01

1.03

1.05

1.07

0.95

0.97

0.99

1.01

1.03

1.05

1.07

1.09

1.11

1.13

1.15

1.17

WATER

CC

F

FIGURE 6

CAPACITY CORRECTION FACTORS, CCF

0.45

0.46

0.47

0.48

0.49

0.50

180160140120100100 120 140 160 180

0.50

0.49

0.48

0.47

0.46

0.45

0.44

0.43

&

50%

40%

30%

20%

10%0%

PROPYLENE GLYCOL MIXTURE

ETHYLENE GLYCOL MIXTURE

0%

10%

20%

30%

40%

50%

AVG FLUID TEMPAVG. FLUID TEMP.

FHF

FHF

Page 15: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

FIGURE 7FLUID PRESSURE DROP, ΔP FLUID

1.00

0

200

400

600

800

1000

1200

1400

1600

1800

2000

2200

2400

2600

10.0

00

14.0

00

1.50

2.00

2.50

3.50

3.00

2.75

3.25

LEN

GTH

FA

CTO

R, L

F

2.00

0

3.00

0

4.00

0

5.00

0

6.00

0

7.00

0

8.00

0

9.00

0

11.0

00

12.0

00

13.0

00

1.60

1.70

1.80

1.90

2.10

2.20

2.30

2.40

2.40 2.30

2.20 2.10

1.90 1.80

1.70

1.603.25

2.75

3.00

3.50

2.50

2.00

1.50 1.20

1.00

1.20

1.00

FLOW FACTOR, FF

ΔP FLUID, PSI

Page 15

Page 16: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 16

FIGURE 8CORRECTION FACTOR, PDF

FLUID PRESSURE DROP

100 110 120 130 140 150 160 170 180

1.00

1.05

1.10

1.15

1.20

1.25

1.30

1.35

1.40

0.95

0.90WATER

10% P.G.

20% P.G.30% P.G.

40% P.G.

50% P.G.

WATER & PROPYLENE GLYCOL

WATER & ETHYLENE GLYCOL

50% E.G.

40% E.G.30% E.G.

20% E.G.

10% E.G.WATER0.85

0.90

0.95

1.40

1.35

1.30

1.25

1.20

1.15

1.10

1.05

1.00

180170160150140130120110100

1.45

1.50

1.55

1.45

CO

RR

EC

TIO

N F

AC

TOR

CO

RR

EC

TIO

N F

AC

TOR

AVG. FLUID TEMP °F AVG. FLUID TEMP °F

0.85

0 7000600050004000300020001000

1.000

1.100

1.010

1.020

1.030

1.040

1.050

1.060

1.070

1.080

1.090

1.110

1.120

1.130

1.140

1.150

1.160

1.170

ALTITUDE, ft

ACF

FIGURE 9ALTITUDE CORRECTION FACTOR

Page 17: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 17

FIGURE 10CAPACITY - 1 FAN FLUID COOLERS

5.0

4.0

3.0

2.0

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

6.0

7.0

0

2.00 2.503.00 3.50

1.752.00

2.503.00

2.003.50

3.002.50

2.001.50

1.00 2.003.00

3.40

2.403.53.002.50

3.20

3.002.00

1.00

2.503.50

2.003.00

3.00

1.80

3.40

2.00 2.202.50

3.50

1.00 2.003.00

3.403.00

2.60

2.403.00

3.402.30 2.60

2.803.20

3.502.80

3.402.403.00

3.20

1.80

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

3.002.00

1.00

2.60

3.00

3.20

2.80

2.40

1.00 2.003.00 3.00

2.502.00

1.75

3.503.00

2.502.00

2.802.60

2.40

GALLONS PER MINUTE

MB

H /

°TD

1 FAN FLUID COOLERS

AFV-62

AFV-84

AFV-96

AFV-119

AFV-127

FLO

W F

AC

TOR

MODEL GPM LENGTH

AFV-62FACTOR

-84

-96

-119

-127

5 - 2526 - 49

384192

672288192

972648324

1296972648432324216

5 - 2122 - 4950 - 74

5 - 2122 - 3132 - 63

5 - 2122 - 2829 - 4243 - 6465 - 8586 - 120

50 - 80 96

9675 - 80

19250 - 80384786

26 - 495 - 25

21664 - 9410895 - 120

LENGTH FACTOR

GPM

AFV-96

AFV-84

AFV-62

AFV-127

AFV-119

Page 18: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 18

FIGURE 11CAPACITY - 2 FAN FLUID COOLERS

3.00

2.00

1.00

2.00

3.00

2.50

3.50

1.50

2.40 2.6

0 2.80

1.80

2.00

2.20

2.40

2.60

2.80

3.00

3.00

1.80

3.50

3.00

1.00

2.00

3.00 2.00

2.50

2.00

1.00

2.20

3.00

3.20

3.40

2.00

3.00

3.40

2.60

3.40

2.20

2.40

3.50

2.50

2.00

3.00

3.00

2.60

2.40

2.80

2.20

2.60 2.8

0 3.00 3.2

0 3.40

2.60

2.80

3.00

3.20

3.40

3.20

010

2030

4050

6070

8090

100

110

120

130

AFV-

254

AFV-

238

AFV-

192

AFV-

167

3.00 3.2

0 3.40

2.00

2.20

2.40

2.60

2.80

3.20

3.40

1.80

1.70

3.00

2.60

2.80

2.60

2.40

1.80

1.80

AFV-

223

1.00

2.20

1.801.501.8

0

1.40

0.60

0.20

FLOW FACTOR

7.0

6.0

5.0

4.0

1020

3040

5060

7080

9010

011

012

013

0

8.0

9.0

10.0

11.0

12.0

13.0

14.0

15.0

GA

LLO

NS

PER

MIN

UTE

MBH / °TD

2 FA

N F

LUID

CO

OLE

RS

MO

DEL

G

PM

LEN

GTH

FAC

TOR

AFV-

167

-192

-238

-254

5 - 1

813

4419

- 49

576

50 -

7338

4

5 - 2

413

44 768

384

25 -

4950

- 98

5 - 1

516

- 32

33 -

63

1944

1296 64

8

5 - 1

719

4418

- 42

1296

43 -

6364

- 84

864

648

85 -

120

432

74 -

120

192

98 -

100

192

64 -

9543

296

- 12

021

6

216

96 -

120

432

64 -

9564

812

9619

44

33 -

6316

- 32

5 - 1

5-2

23

LEN

GTH

FAC

TOR

GPM

Exam

ple,

12.

9M

BH

/TD

*Exa

mpl

e, L

F =

648

*

Exam

ple,

FF

= 3.

33

AFV-

167

AFV-

254

AFV-

223

AFV-

238

AFV-

192

Page 19: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 19

FIGURE 12CAPACITY - 3 FAN FLUID COOLERS

AFV

-251

AFV

-288

AFV

-381

190

180

170

160

150

140

130

120

110

100

9080

7060

5040

3020

10

2.40

3.40

3.20

2.80

2.60

2.40

2.20

2.00

3.40

3.20

3.00

3.20

3.40

3.20

3.00

2.80

2.603.40

3.20

3.00

2.80

2.60

2.80

2.40

2.60

3.00

2.40

2.40

2.50

2.00

1.80

3.00

3.50

1.80

3.00

3.00

2.80

2.60

2.40

2.20

2.00

1.80

2.80

2.60

2.401.

803.

402.

603.

002.

20

2.20

2.00

1.80

2.60

2.80

2.40

2.20

2.00

1.90

2.10

2.30

2.50

3.40 1.

801.

602.

00

1.40

1.001.20 1.4

02.2

0

1.50

1.60 1.80 2.00 2.20

FLOW FACTOR

10.0 9.0

8.0

7.0

1020

3040

5060

7080

9010

011

012

013

014

015

0

11.0

12.0

13.0

14.0

15.0

16.0

17.0

18.0

19.0

20.0

21.0

160

170

180

190

GA

LLO

NS

PER

MIN

UTE

MBH / °TD

3 FA

N F

LUID

CO

OLE

RS

AFV

-251

AFV

-288

AFV

-357

AFV

-381

MO

DE

L

G

PM

LEN

GTH

FAC

TOR

AFV

-251 -2

88

-357

-381

5 - 4

986

4

50 -

7357

6

5 - 1

820

16

1152 57

6

19 -

49

50 -

98

5 - 2

1

22 -

63

1944 97

2

5 - 2

919

44

30 -

63

64 -

84

1296 97

2

85 -

126

648

74 -

140

288

98 -

160

288

64 -

9564

8

96 -

180

324

324

127-

180

LEN

GTH

FA

CTO

R

GPM

2.40

3.00

2.60

3.40

1.80

1.40

1.702.10

2.20

1.90

2.303.

403.

203.

002.

802.

602.

402.

20

3.00

3.20

3.40

2.00

2.80

2.60

1.80

AFV

-357

Page 20: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 20

FIGURE 13CAPACITY - 4 FAN FLUID COOLERS

MO

DE

L

G

PM

LEN

GTH

FAC

TOR

AFV

-307 -3

35

-384

-446

5 - 4

911

52

50 -

7376

8

74 -

140

384

5 - 4

215

36 768

384

43 -

98

99 -

160

5 - 5

7

58 -

94

1296 864

5 - 4

717

28

48 -

81

82 -

126

1296 864

126-

240

432

95 -

180

432

-476

-509

LEN

GTH

FA

CTO

R

230

220

240

210

200

190

180

170

160

150

140

130

120

110

100

9080

7060

5040

30

1.80

1.80

2.402.60 2.80

2.40

3.40

3.20

2.80

2.60

2.40

2.20

2.00

3.40

3.20

3.00

3.20

3.20

3.00

2.80

2.60

2.60

2.80

2.40

2.60

3.00

2.40

2.20

2.60

3.00

2.00

3.40

3.20

3.00

2.20

2.50

3.00

1.80

3.003.

002.

802.

602.

402.

202.

001.

80

2.80

2.60

2.40

3.50

2.50

3.00

2.20

2.00

1.80

2.60

2.80

2.40

2.60

2.80

3.00

3.20

3.40

2.40

2.20

2.00

1.90

2.10

2.30

3.40 1.8

02.5

03.1

02.9

02.7

02.6

02.8

03.0

03.2

03.3

03.4

0

2.20

2.00

1.80

2.00 2.20 2.40 2.20

1.60

3.40

FLOW FACTORA

FV-5

09

AFV

-476

AFV

-446

AFV

-384

AFV

-335

AFV

-307

12.0

11.0

3040

5060

7080

9010

011

012

013

014

015

016

017

018

019

020

021

024

022

0

13.0

14.0

15.0

16.0

17.0

18.0

19.0

20.0

21.0

22.0

23.0

24.0

25.0

26.0

27.0

28.0

230

GA

LLO

NS

PER

MIN

UTE

MBH / °TD

4 FA

N F

LUID

CO

OLE

RS

GPM

AFV

-446

AFV

-476

AFV

-509

AFV

-384

AFV

-335

AFV

-307

Page 21: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 21

FIGURE 14CAPACITY - 5 AND 6 FAN FLUID COOLERS

1296

1944

59 -

122

30 -

58

1620

30 -

67

1944

253-

500

169-

252

123-

168

44 -

9230

- 43

324

648

972

1296

1080

1620

52 -

9430

- 51

-7

63

-7

14

-6

36

FAC

TOR

AFV

-595

MO

DE

L

GP

M

L

EN

GTH

972

93 -

126

1080

68 -

126

540

127-

240

648

127-

189

540

95 -

180

324

190-

380

LEN

GTH

FA

CTO

R

500

480

460

440

420

400

380

360

340

320

300

280

260

240

4060

8010

012

014

016

018

020

022

0

2.20

1.80

2.00

2.20

2.40

2.60

2.80

3.20

3.40

2.60

2.40 2.60 2.80 3.00 3.20 3.401.80

2.00

2.20

2.40

2.60

2.80

3.00

3.20

3.40

2.80

2.40

2.60

2.20

2.00

1.80

2.80 3.00 3.20 3.402.402.602.803.003.203.40

3.00

3.20

3.402.60

2.40

2.60

2.40

2.60

2.40

2.00

1.80

2.20

2.80 3.00 3.20 3.40

2.80 3.0

0 3.20 3.4

0

3.00

2.80

3.40

3.20

2.80

3.00

3.20

3.40

2.40 2.60 2.80 3.00 3.20 3.40

3.20

2.80

2.40

1.802.20

1.401.40

2.20

1.802.60

1.801.80 2.20

2.60

2.20

1.80 2.00

1.60

1.602.00

2.20

2.00

1.80

2.00 2.20

AFV

-595

AFV

-636

AFV

-714

AFV

-763

FLOW FACTOR

30.0

28.0

26.0

24.0

22.0

20.0

18.0

16.0

220

200

180

160

140

120

100

8060

40

14.0

32.0

34.0

36.0

38.0

40.0

42.0

240

260

280

300

320

340

360

380

400

420

440

460

480

500

GA

LLO

NS

PER

MIN

UTE

MBH / °TD

5 FA

N F

LUID

CO

OLE

RS

AFV

-636

AFV

-595

AFV

-714

AFV

-763

GPM

6 FA

N F

LUID

CO

OLE

RS

Page 22: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 22

FIGURE 15CAPACITY - 8 FAN FLUID COOLERS

864

1296

164-

252

95 -

163

51 -

9430

- 50

253-

500

432

1728

2592

-10

17

-9

52

FAC

TOR

MO

DE

L

GP

M

LEN

GTH

190-

380

432

123-

189

864

AFV

-893

1296

30 -

7071

- 12

217

28

1728

71 -

122

30 -

70

1296 864

123-

189

432

190-

380

LEN

GTH

FA

CTO

R

500

480

460

440

420

400

380

360

340

320

300

280

260

240

4060

8010

012

014

016

018

020

022

0

2.60

2.40

2.60

2.40

2.60

2.40

2.00

1.80

2.20

2.80 3.00 3.20 3.40

3.00

2.80

3.40

3.20

2.80

3.00

3.20

3.40

3.40

3.20

3.00

3.40

3.20

3.00

2.80

2.60

2.40

3.40

3.20

3.00

2.80

1.80

2.00

2.20

2.60

2.40

2.80

2.00

1.50

2.60

2.20

1.80

1.40

2.20

2.00

1.80

1.40 1.60

2.20 2.40 2.60

2.00

2.40

2.20

2.00

2.60

AFV

-893

AFV

-952

AFV

-101

7

FLOW FACTOR

46.0

44.0

42.0

40.0

38.0

36.0

18.0

20.0

22.0

24.0

26.0

28.0

30.0

32.0

34.0

48.0

50.0

52.0

54.0

56.0

GA

LLO

NS

PER

MIN

UTE

MBH / °TD

8 FA

N F

LUID

CO

OLE

RS

GPM

AFV

-893

AFV

-952

AFV

-101

7

500

480

460

440

420

400

380

360

340

320

300

280

260

240

4060

8010

012

014

016

018

020

022

0

Page 23: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Page 23

FIGURE 16CAPACITY - 10 FAN FLUID COOLERS

2.80

2.402.60

2.20

2.00

1.80

2.40 2.60 2.80 3.00 3.20 3.40

3.003.20

3.40

3.40

3.20

3.00

2.80

3.20 3.40

2.80 3.00

2.20

2.00

2.40 2.60

2.40

2.60

220

200

180

160

140

120

100

8024

026

028

030

032

034

036

038

040

042

044

046

048

050

0

1.80

520

540

560

580

600

620

640

660

680

700

720

740

3.40

3.20

3.00

3.40

3.20

3.00

2.80

2.60

2.40

1.802.00

2.20

2.60

2.40

2.80

1.80

2.60

2.40

2.60

2.00

2.20

3.00

2.80

3.40

3.20

2.80

3.00

3.202.20

2.00

1.80

3.00

2.80

3.203.40

2.60

2.00

1.60

3.40

3.20

3.00

2.80

2.60

2.40

1.90

2.10

2.402.502.60

2.80

2.30

2.70

2.903.003.10

3.203.303.40

2.80

2.40

2.60

2.20

1.80

2.60

2.20

1.80

2.602.402.20

2.20

2.00

2.00 2.20

2.40 2.60 2.802.0

0 2.20

2.002.202.4

0

2.20

2.00

1.80

2.20

1.80

FLOW FACTOR

AFV

-127

1

AFV

-119

0

AFV

-142

5

AFV

-111

6

AFV

-150

2

AFV

-162

5

62.0

60.0

58.0

56.0

54.0

52.0

34.0

8010

0

36.0

38.0

40.0

42.0

44.0

46.0

48.0

50.0

64.0

66.0

68.0

70.0

72.0

74.0

76.0

78.0

80.0

82.0

84.0

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

680

700

720

740

GA

LLO

NS

PE

R M

INU

TE

MBH / °TD

10 F

AN

FLU

ID C

OO

LER

S

AFV

-111

6

AFV

-119

0

AFV

-127

1

AFV

-142

5

AFV

-150

2

AFV

-162

5

GP

M

LEN

GTH

FA

CTO

R

1620

102-

189

80-1

01

1080

AFV

-111

6

540

190-

378

MO

DE

L

G

PM

L

EN

GTH

FAC

TOR

-1

190

-12

71

1620

1080

80-1

01

102-

189

190-

378

540

80-1

3416

20

1080

135-

252

253-

500

540

-14

25

-15

02

540

253-

500

135-

252

1080

1620

80-1

3454

019

0-37

8

102-

189

80-1

01

1080

1620

80-1

5121

60

1620

152-

202

203-

378

1080

379-

740

540

-16

25

Page 24: Direct Drive Remote Air-Cooled Fluid Coolers 33 Models · 2016. 5. 26. · Colmac AFV/AFH model air-cooled fluid coolers are designed to provide cooling of Water, Ethylene Glycol/Water

Other Quality Products From Colmac Coil

Midwest US ManufacturingColmac Coil Midwest350 Baltimore Dr. | Paxton, IL 60957 | USA

North American HeadquartersColmac Coil Manufacturing, Inc.370 N. Lincoln St. | P.O. Box 571Colville, WA 99114 | USA+1.509.684.2595 | +1.800.845.6778

CE(PED) Certification, ASME Sec. VIII, Canadian Registration Number, UL508, Canadian Standards Association

CRN CSA

©2012 Colmac Coil "The Heat Transfer Experts"

Heat Pipes for Heat Recovery

Custom Evaporators & Baudelot Coolers

Heating and Cooling Coils Air Cooled CondensersDry Coolers for Glycol or Gas Cooling

Visit www.colmaccoil.com for more information and resources:

Product Information

Product Literature

Sales Rep Locator

Sales Rep e-Library

Product Videos