  • 7/26/2019 Digester specs sheet

    1/1

    FEATURES

    Optimally design pretreatment, feeding anddistributions of POME to digesters.

    Innovative and efficient digester mixing.

    Efficient biogas capture and distribution;

    with built-in gas-holder.

    Providing optimised operational and control

    parameters based on long-term continuous

    operations experience.

    Incorporates efficient control, monitoring

    and safety features, including excess gas

    auto-flaring.

    BENEFITS

    High reliability and efficiency in methane

    recovery, ~0.35 Nm3/kg COD.

    Low power consumption, low O&M costs.

    Regulated biogas output for direct use as boiler

    fuel and power generation.

    Ease of operations with simple and well planned

    operational and maintenance schedule; no need

    of system shut down for maintenance.

    Minimised risks of digester failure; improvedtreated effluent quality for subsequent

    facultative/aerobic treatment.

    RAW POME

    30-MT FFB/h

    POME: 400 m3/day

    BOD: 25,000-35,000 mg/LCOD: 45,000-70,000 mg/L(with Juice from EFB)

    BIOGAS

    Production: 11,200 m /dComposition:

    CH4: 62.5%CO2: 37%H2S: 1,500-3,000 vppm

    DIGESTED POME

    Flow: 400 m /day

    BODdissolved: ~500 mg/L

    COD otal: 8,000-12,000 mg/LCODdiss: ~3,000 mg/L

    SLUDGERETURN

    ANAEROBIC DIGESTER

    Gas Chromatographic Analysis

    of POME Biogas

    SPECIFICATIONS OF NOVAVIRO-KS ANAEROBIC

    DIGESTER TECHNOLOGY:

    The Anaerobic Digester Technology has been perfected over 20 years of continuous full scale operations.

    The highly efficient anaerobic digestion design of our system allows maximum recovery of methane

    possible from the optimally controlled operation of POME anaerobic digestion.

    Technology: Continuous-Flow Stirred-Tank Reactor(CSTR) Contact Process

    2 units Floating Roof & 1 unit Fixed Closed tanks Combined Capacity: 7,500 m3 (HRT: 18 days) Pum o erated dual-function com letel mixed