TRANSCRIPT
SPECSVISION-COMD
SYSTEM FEATURES
Newest version based on recent IACS
Effectiveness verified based on M67 rules
Superior accuracy verified
Most rigid construction
Instantaneous response to alarm
RS-485 / 422 to IAS
Less contaminated sensor design
Highly integrated single board design
Robust anti-vibration construction
Multi- functional remote monitoring unit
Proven test and calibration chamber
Diesel Engine Crank Case
Oil Mist Detection System
Diesel Engine Crank Case OMD System
AMS / IAS
Remote Monitoring Unit (VISION IIIR)
Junction Box (VISION IIIJC)
Crank Case OMD (VISION IIIC)
RS-485
24 VDC
RS-485
24 VDCpower
RS-485
Common Alarms(Mist, System)
24 VDC
Head OfficeB-7 Floors Technopark, 148, Yatap-dong, Bundang-gu,
Seongnam City, Gyeonggi-do, Korea 463-070
TEL +82-31-706-5211 FAX +82-31-706-5214
http://www.specsvision.com, www.specs.co.kr
Email [email protected]
Busan Office#704, Byucksan Digital Valley, 132-7, Gamheon2-dong,
Sasang-gu, Busan, Korea 617-800
TEL +82-51-803-0041 FAX +82-51-804-3364
Email [email protected]
TECHNICAL SPECIFICATIONS
Type
Sensitivity
Communication
Between RMU & Detector
Indication
5- Way Plug in Connector
Mounting
Enclosure Rating
Power
Temp. Rating(Operation)
Dimensions
Weight
Housing
Type
Max. No. of Detector Input
Enclosure Rating
Temp. Rating
Dimensions
Weight
Housing
Detector Unit
Junction Box
VISION IIIC
0.01 mg/ℓ
RS-485
3/4” BSP
IP 56
24 VDC
0 ℃ to 70 ℃
H 150 x W 84 x D 203 mm
0.5 kg
PPA +GF 30%, Halogen free
Green : Power ONYellow : System FaultRed : Mist Alarm
Power : 1, 2 pinSignal : 3, 4 pinShield : 5 pin
Alarm & Failure Status
Mist Alarm
Mist high alarm
Pre-warning alarm
System fault alarm
Alarm Setting
Alarm Contacts
Enclosure Rating
Power
Current rating
Fuse rating
Over voltage protection
Temp. Rating
Dimensions
Wall
Flush
Weight
Housing
Type
Display
Scanning Time
Max. No. of Group
Measuring Range
Communication Signal
Input
Output
Memory
Event log
History log
Remote Monitoring Unit (RMU)
IP 44
24 VDC
1.5 A
2.0 A
+30 % -20 % of voltage rating (24 VDC)
0 ℃ to 70 ℃
H 200 x W 318 x D 102 mm
H 237 x W 353 x D 102 mm
6.0 kg Gross
Carbon Steel
RMU- Red LED ON (Alarm Indicator Panel)
Alarm Channel Displayed on LCD
VISION IIIR
50 msec for each point
8 Engine Groups
0~5.00 mg/ℓ
RS-485 (protocol; MODBUS)
RS-485 (protocol; MODBUS Dual)
3000 Data
10 sec x 12 hrs
6” Monochrome LCD (340 x 280)Mist- Level Display Mode (Bar & Digital Value)
RMU- Yellow LED ON(Fan/Communication Alarm Indicator Panel)and Failed Channel Displayed on LCD
Mist High Alarm (Max. 2.5 mg/ℓ)Pre-warning alarm; User adjustable
Mist High N.O (8 ea)Pre-warning alarm; N.C (8 ea)N.O/N.C selectable125 VAC 0.5 A, 30 VDC 1.0 A, 1a1b
VISION IIIJA
14 Serial (Loop) Connection
IP 56
0 ℃ to 70 ℃
H 75 x W 90 x D 45 mm
0.35 kg
PPA Plastic
FRONT VIEW SIDE VIEW
353153 153
237
226
102
200
6x05