df me a chrysler example
TRANSCRIPT
-
7/27/2019 Df Me a Chrysler Example
1/2
Revision 6.0 2/11/98Design FMEA
System
Subsystem
Component
CustomerChrysler Motors Corporation
Customer Part No.DC-77323-XYZ
Org. Date2/11/98
Page1 of 2
SupplierAny Company, Inc.
CodeACI-001
Supplier Part No.A-9514
Dwg. Rev.8
Key Date2/11/98
FMEA No.DFMEA-001
Part NameFilter
Design ResponsibilityBrad Anderson
Application/Model YearSedan / 1998
Core TeamBrad Anderson,Jerry Benware,Lisa Brown,Ken Caracci,Bill Cox,Fred Jordan,Ken Kratz
Prepared ByBrad A. Anderson
Date2/11/98
Approved By
Brad A. Anderson
Date
2/11/98
Item /Function
PotentialFailureMode
PotentialEffect(s) of
Failure
Sev
Class
PotentialCause(s) /
Mechanismsof Failure
Occur
CurrentDesign
Controls
Detec
R.P.N.
RecommendedAction(s)
Responsibility& Target
Completion Date
Action Results
ActionsTaken
Sev
Occ
Det
R.P.N.
Filter forassembly with
B44 to firewall
Insufficient waxcoverage over
specified surface
Deteriorated life ofdoor leading to:
Unsatisfactoryappearance due torust through paintover time, Impairedfunction of interiordoor hardware
4 Insufficient waxthickness specified
4 Supplier certification 1 16 None N/A2/11/98
Inappropriate waxspecified
5 set upset up
4 80
Five piece setup,in-process, end ofrun study
2 40 None N/A2/11/98
Corroded interiorlower door panels
Improper oxide coat ing 6 Entrapped airprevents wax fromentering corner/edgeaccess
6 Test spray pattern atstartup and after idleperiods, and ...
5 180 Add team evaluationusing productionspray equipmentand specified wax
Engineering andAssemblyOperations2/18/98
Based on testreults (Test#9989) spray headmodified to ...
6 2 5 60
Spray headsclogged: Viscositytoo high,Temperature too
low, Pressure too low
4 Incomming audit per200-16 certification,SPC Lot/Qtr
2 48
Laboratory testusing "worst case"wax and applicationhole size
3 72 Add laboratoryacceleratedcorrosion testing
ABC Labs2/27/98
Test results showspecified ...
6 3 3 54
Conduct DOE onwax thickness
EngineeringAssociates2/18/98
DOE shows 25%variation inspecifiedthickness isacceptable
6 2 2 24
Feeder not
properly or
3
-
7/27/2019 Df Me a Chrysler Example
2/2
Revision 6.0 2/11/98Design FMEA
System
Subsystem
Component
Chrysler MotorsCustomer PartDC-77323-XYZ
Org.2/11/98 2of 2
SupplierAny Company, Inc.
CodeACI-001
Supplier Part No.A-9514
Dwg. Rev.8
Key Date2/11/98
FMEA No.DFMEA-001
Part NameFilter
Design ResponsibilityBradAnderson
Application/Model YearSedan / 1998
Core TeamBrad Anderson,Jerry Benware,Lisa Brown,Ken Caracci,Bill Cox,Fred Jordan,Ken Kratz
Prepared ByBrad A. Anderson
Date2/11/98
Approved By
Brad A. Anderson
Date
2/11/98
Item /Function
PotentialFailureMode
PotentialEffect(s) of
Failure
Sev
Class
PotentialCause(s) /
Mechanismsof Failure
Occur
CurrentDesign
Controls
Detec
R.P.N.
RecommendedAction(s)
Responsibility& Target
Completion Date
Action Results
ActionsTaken
Sev
Occ
Det
R.P.N.
Customer complaint,rework
7 Inappropriate waxspecified
5 aidinvestigationnon-functioningspray
4 140 startupprocedure
engineering
Laboratory test"worst case"
and applicationsize
5
Laboratorycertificationper 200-10
140
Entrapped airprevents wax fromentering corner/edgeaccess
4 Five piece setup,in-process, end ofrun study
4 112