1:16 - det3396 OREGON DEPARTMENT OF TRANSPORTATION TECHNICAL SERVICES BULB-I GIRDER SCHEDULE, POST-TENSIONED END BLOCK AND MISCELLANEOUS DETAILS DETAIL NO. DET3396 DETAILS DET3396 FIGURES FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 "N" "y " c "N" "y " c FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 Reinforcing Bars "a" "b" "m" "D " L R "D " End Block Back End (On Stationing) Girder Type Span Number "F " L "E " L "E " R "F " R "F " L "E " L "E " R "F " R GIRDER SCHEDULE 1"cl. Possible strand locations. 2’-2" w/8" web 1"cl. 2" 3" #3 "U3" bars, see Midspan Section for bar spacing. 2" 1 3/4 "cl. w/7 1/2 " web 1’-8" w/8" web No Scale "X" B B (Alternate B) Cable restraints top and bottom at each Beam D. Midspan Deck Build-up as required A A varies B B B B B B 6 @ 3" Bar "U5" stirrups Bar "U4" stirrups spacing "b" @ 12" 18" max. spcg. w/ 7 1/2 " web w/ 8" web 12" 4’-0" transition Midspan section 1 1/2 "| 6 spcs. @ 10" max. (9 1/2 " average spacing) Skew end plan #4 "U9" bar Girder Depth-2 3/8 " (Normal dimension, adjust first bar for skew) EST. MIDSPAN DEFLECTION Girder Mass, Kips 2"cl. w/8" web 2-#5 x cont. bars, stagger splices. #4 "U1" bars at 18" max. ctrs. 2-#5 x 2’-6" epoxy coated dowels each side projecting 12" out of beam end. 1’-7 1/2 " w/7 1/2 " web 2-#5 x 2’-6" epoxy coated dowels each side projecting 12" out of beam end. 1 3/4 "cl. w/7 1/2 " web 2"cl. w/8" web 2’-1 1/2 " w/7 1/2 " web 6" 1 3/4 "cl. w/7 1/2 " web 2"cl. w/8" web #4 longit. btwn. ducts each face of web when clear distance btwn. ducts is 4" or greater. 7 @ 1’-3" 1 @ 1’-0 3/4 " 1 @ 10 1/2 " 1 @ 8" 6" 6" 4’-9" 3’-3" 3 @ 9" 3’-3 3/8 " 1’-4" #4 "U11" bar 2’-1 1/2 " 2’-2" 1 3/4 " 9 @ 4" "a" @ 6" 5’-0" end block 7’-0" BI84 8’-0" BI96 9’-0" BI108 6" #5 x 2’-6" epoxy coated dowels btwn. post-tensioning ducts each side projecting 12" out of beam end. Note: For temporary diaphragm beam details, see dwg. BR350 BUILD - UP DECK DETAIL END BLOCK END VIEW STEM SECTION AT END BLOCK END BLOCK SIDE ELEVATION #4 "U11" BAR #4 "U9" BAR Girder Number Number Required LT. = Lt. Exterior RT. = Rt. Exterior Span ctr. - ctr. Bents along Girder { "A", o-o Girder (Horiz. Length after Shortening) Concrete Strength @ 28 Days, Ksi Concrete Strength @ Release, Ksi Initial Tension per Strand, Kips Number of Strands per Girder "N" Figure Number for Strand Pattern (Stirrup Leg) Stirrup Spaces Negative Value Indicates Back from Midspan Diaphragm Ahead End (On Stationing) End Block Negative Value Indicates Point Beyond Girder End Negative Value Indicates Point Beyond Girder End Upward at Release Upward 3 Months after Release Estimated Shortening 2 Weeks after Release #4 "U9" bars at 8" max. #4 "U9" bars @ 8" max. W12 "U2" bars (galv.) at 6" alternate "U5" stirrups (1st., 3rd, 5th, and 7th). 2-#13 x cont. each side, stagger splice. 2-#6 x cont. each side, stagger splices. SECTION A-A W12 "U2" bars @ 6" ctrs. on 1st, 3rd, 5th and 7th stirrups (from girder ends). 8" (Alternate A) One cable restraint at location shown. After restraint is removed, fill hole with concrete and finish flush with surface of girder (exterior girders only). Minimum deck thickness. This dimension assumes girder fabrication and erection will meet the required deck elevations. In case of variations, lower girder to meet corrected elevation. GIRDER RESTRAINT DIAGRAM Snug fit prestressed girders against forms prior to diaphragm pour. Keep restraints in place a min. of two days after completion of diaphragm pour. DET3396 NOTE TO DESIGNER Design girders using 3/4 " min. build-up over girders. Ensure girder soffits are on level grade prior to prestressing. Use build-up over girder to compensate for the difference between deck elevation and girder camber. When the girder build-up exceeds 3" and/or the girder stirrups extend less than 2" into the deck, add #4 stirrup extensions. Place stirrup extensions at each girder stirrups and tie to the girder stirrup. Where girder stirrup spacing is 6" or less, place stirrup extentions @ 12" max. #4 stirrup extension Note: Transport members in accordance with Section 00550.51 of the Standard Specifications for Highway Construction. Place members no less than _____ days after casting. NOTE TO DESIGNER Remove note if 7 day transport and placement is okay without placement restrictions. NOTE TO DESIGNER End Blocks are typically not necessary at continous bents.

Upload: gabemzaman

Post on 06-Nov-2015

7 views

Category:

Documents


0 download

DESCRIPTION

t

TRANSCRIPT

  • 1:16 - det3396

    OREGON DEPARTMENT OF TRANSPORTATIONTECHNICAL SERVICES

    BULB-I GIRDER SCHEDULE,POST-TENSIONED END BLOCK

    AND MISCELLANEOUS DETAILS

    DETAIL NO.

    DET3396

    DETAILS

    DE

    T3

    396

    FIGURES

    FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4

    "N"

    "y "c

    "N"

    "y "c

    FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8

    Reinforcing Bars

    "a" "b" "m" "D "L R"D "

    En

    d B

    lock

    Back End (On Stationing)G

    irder

    Type

    Sp

    an

    Nu

    mb

    er

    "F "L"E "L

    "E "R "F "R "F "L

    "E "L"E "

    R "F "R

    GIRDER SCHEDULE

    1"c

    l.

    Possible strand locations.

    2-2" w/8" web

    1"c

    l.

    2"

    3"

    #3 "U3" bars, seeMidspan Section forbar spacing.

    2"

    1 3/4 "cl. w/7 1/2 " web

    1-8" w/8" web

    No Scale

    "X

    " B

    B

    (Alternate B)Cable restraints top

    and bottom at each

    Beam D.

    MidspanDeck

    Build-upas required

    A

    A

    varie

    s

    B B B

    B

    B

    B

    6 @ 3"

    Bar "U5"stirrups

    Bar "U4" stirrups spacing

    "b" @ 12" 18" max. spcg.

    w/

    7 1

    /2 "

    web

    w/

    8" w

    eb

    12"

    4-0" transition Midspan section

    1 1/2 "| 6 spcs. @ 10" max.(9 1/2 " average spacing)

    Skew end plan

    #4 "U9" bar

    Gir

    der

    Dep

    th-2

    3/8

    "

    (Normal dimension,adjust first barfor skew)

    EST. MIDSPANDEFLECTION

    Gir

    der

    Mass

    , K

    ips

    2"cl. w/8" web

    2-#5 x cont. bars,stagger splices.

    #4 "U1" bars at18" max. ctrs.

    2-#5 x 2-6" epoxycoated dowels eachside projecting 12"out of beam end.

    1-7 1/2 " w/7 1/2 " web

    2-#5 x 2-6" epoxycoated dowels each sideprojecting 12" outof beam end.

    1 3/4 "cl. w/7 1/2 " web

    2"cl. w/8" web2-1 1/2 " w/7 1/2 " web

    6"

    1 3/4 "cl. w/7 1/2 " web

    2"cl. w/8" web

    #4 longit. btwn. ducts eachface of web when clear distancebtwn. ducts is 4" or greater.

    7 @ 1-3"1 @ 1-0 3/4 "1 @ 10 1/2 "1 @ 8"

    6"6"

    4-9" 3-3"

    3 @ 9"

    3-3 3/8 "

    1-

    4"

    #4 "U11" bar2

    -1

    1/2

    "

    2-

    2"

    1 3/4 " 9 @ 4" "a" @ 6"

    5-0" end block

    7-

    0" B

    I84

    8-

    0" B

    I96

    9-

    0" B

    I108

    6"

    #5 x 2-6" epoxycoated dowels btwn.post-tensioning ductseach side projecting12" out of beam end.

    Note:

    For temporary diaphragm

    beam details, see dwg. BR350

    BUILD - UP DECK DETAIL

    END BLOCK END VIEW

    STEM SECTION AT END BLOCK

    END BLOCK SIDE ELEVATION

    #4 "U11" BAR

    #4 "U9" BAR

    Gir

    der

    Nu

    mb

    er

    Num

    ber

    Requir

    ed

    LT

    . =

    Lt.

    Exte

    rior

    RT

    . =

    Rt.

    Ex

    teri

    or

    Sp

    an

    ctr

    . -

    ctr

    .B

    en

    ts a

    lon

    g

    Gir

    der

    {

    "A

    ",

    o-o

    Gir

    der

    (Hor

    iz. L

    engt

    haft

    er

    Sh

    ort

    en

    ing

    )

    Concre

    te S

    trength

    @ 2

    8 D

    ay

    s, K

    si

    Concre

    te S

    trength

    @ R

    ele

    ase

    , K

    si

    Init

    ial

    Ten

    sio

    np

    er

    Str

    an

    d,

    Kip

    s

    Num

    ber

    of

    Str

    ands

    per

    Gir

    der

    "N"

    Fig

    ure

    Nu

    mb

    er f

    or

    Str

    and P

    att

    ern

    (Stir

    rup

    Leg)

    StirrupSpaces

    Negative ValueIndicates Backfrom Midspan

    Diaphragm Ahead End (On Stationing)

    En

    d B

    lock

    Negative Value IndicatesPoint Beyond Girder End

    Negative Value IndicatesPoint Beyond Girder End

    Upward atRelease

    Upward 3Months after

    Release

    Est

    imat

    ed

    Sh

    ort

    enin

    g 2

    Wee

    ks

    aft

    er

    Rele

    ase

    #4 "U9" bars at 8" max.

    #4 "U9" bars @ 8" max.

    W12 "U2" bars(galv.) at 6" alternate "U5" stirrups (1st., 3rd, 5th, and 7th).

    2-#13 x cont. each side, stagger splice.

    2-#6 x cont.each side,stagger splices.

    SECTION A-A

    W12 "U2" bars @ 6" ctrs. on 1st, 3rd, 5th and 7th stirrups (from girder ends).

    8"

    (Alternate A)One cable restraint at location

    shown. After restraint is removed,

    fill hole with concrete and finish

    flush with surface of girder

    (exterior girders only).

    Minimum deck thickness. Thisdimension assumes girderfabrication and erection will meetthe required deck elevations. Incase of variations, lower girderto meet corrected elevation.

    GIRDER RESTRAINT DIAGRAM

    Snug fit prestressed girders against forms prior to diaphragm

    pour. Keep restraints in place a min. of two days after

    completion of diaphragm pour.

    DE

    T3

    396

    NOTE TO DESIGNER

    Design girders using 3/4 " min.build-up over girders.

    Ensure girder soffits are on level grade prior

    to prestressing. Use build-up over girder to

    compensate for the difference between deck

    elevation and girder camber.

    When the girder build-up exceeds 3" and/or

    the girder stirrups extend less than 2" into

    the deck, add #4 stirrup extensions.

    Place stirrup extensions at each girder

    stirrups and tie to the girder stirrup.

    Where girder stirrup spacing is

    6" or less, place stirrup

    extentions @ 12" max.

    #4 stirrup

    extension

    Note:Transport members in accordance with Section 00550.51 of theStandard Specifications for Highway Construction. Place membersno less than _____ days after casting.

    NOTE TO DESIGNER

    Remove note if 7 day transport and placementis okay without placement restrictions.

    NOTE TO DESIGNER

    End Blocks are typically notnecessary at continous bents.