design construction group the governor nelson a. … 04 c.pdf · 2019. 4. 18. · updated...
TRANSCRIPT
Updated 05/24/2018
Printed 04/18/2019 Page 1 of 1 Project No. 44798-C
DESIGN & CONSTRUCTION GROUP THE GOVERNOR NELSON A. ROCKEFELLER
EMPIRE STATE PLAZA ALBANY, NY 12242
ADDENDUM NO. 4 TO PROJECT NO. 44798
CONSTRUCTION WORK
REPAIR EXTERIOR FAÇADE SHIRLEY CHISHOLM STATE OFFICE BUILDING
55 HANSON PLACE BROOKLYN, NY
April 18, 2019 NOTE: This Addendum forms a part of the Contract Documents. Insert it in the Project Manual.
Acknowledge receipt of this Addendum in the space provided on the Bid Form. SPECIFICATIONS 1. Revised Drawings:
a. Drawing No., A-006, A-007, A-008, A-009, A011, and A-206 noted “REVISED DRAWING 4/17/2019” accompanies this Addendum and supersedes the same numbered originally issued Drawing.
END OF ADDENDUM
Erik T. Deyoe, P.E. Director, Division of Design Design & Construction KM:jc
1 01/16/2019 FINAL SUBMISSION
WARNING:
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THENEW YORK STATE EDUCATION LAW AND/OR REGULATIONS
ENGINEER FOR AN ENGINEER OR LANDSCAPE ARCHITECT
UNLESS DONE UNDER THE DIRECTION OF A COMPARABLE
AND IS A CLASS 'A' MISDEMEANOR.
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
THE ALTERATION OF THIS MATERIAL IN ANY WAY,
CLIENT:
CONTRACT:
TITLE:
LOCATION:
SHEET TITLE:
DESIGNED BY:
PROJECT
DRAWN BY:
DRAWING NUMBER:
FIELD CHECK:
APPROVED:
SHEET OF
MARK DATE DESCRIPTION
NUMBER:
REPAIR EXTERIOR FACADE
SHIRLEY CHISHOLM STATE OFFICE BLDG.55 HANSON PLACE
BROOKLYN, NY 11217
NEW YORK STATEOFFICE OF GENERAL SERVICES
44798
36x2
4 PL
OT
SHEE
T
CONSULTANT
May
04,
2017
- 10
:41a
m /V
olum
es/F
ile S
erve
r/PRO
JEC
T LI
ST c
urre
nt/1
7157
55
Han
son
Plac
e Ex
terio
r Reh
ab/1
7157
CAD
D/D.
1715
7 C
on D
oc -
Prog
ress
Set
s/Dr
awin
gTem
plat
es/G
-BS3
624.
dwg
- C
CONSTRUCTION
DESIGN & CONSTRUCTION
CTA ARCHITECTS P.C.
EXISTING / REMOVALELEVATION - SOUTH
A-006
SM
MJ / CT
APPROVED
SM HZ AR
2 04/17/2019 ADDENDUM 4
1915
SHIRLEY A. CHISHOLM STATE OFFICE BUILDING
55~~~ ~~~~~ ~~~~~~~~~ ~~ ~~~ ~~~
~~ ~~ ~~~~ ~~~~~~~~ ~~ ~ ~~~ ~~~~~~ ~~~ ~~ ~~ ~~~~
SHIRLEY A CHISHOLMSTATE OFFICE BUILDING
~~~ ~~~~~ ~~~~~ ~~~~ ~~ ~~~ ~~~~~~ ~~ ~~~ ~~~ ~ ~~~~~~ ~ ~~~~~ ~~ ~~~~ ~~~~~ ~ ~~ ~~~~ ~~ ~~~~ ~~ ~ ~~~ ~~~~ ~~ ~~ ~~~ ~~~
GENERAL NOTES:
1. REFER TO ROOF PLAN AND BULKHEAD DRAWINGS FOR ADDITIONAL SCOPE.
2. AT ALL LOCATIONS OF ABATEMENT INCLUDE TEMPORARY PROTECTION TO MAINTAIN WATER TIGHTNESS.
REFER TO AREAWAYELEVATIONS, SHEET A-010, FOR
SCOPE. TYP.
10TH FLOOR+/- 104'-0"
+/-1
7'-0
"+/
-13'
-0"
+/-1
0'-0
"+/
-11'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-6
"+/
-12'
-6"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
3'-1
0"+/
-3'-4
"
11TH FLOOR+/- 114'-0"
9TH FLOOR+/- 94'-0"
8TH FLOOR+/- 81'-6"
7TH FLOOR+/- 71'-0"
6TH FLOOR+/- 61'-0"
5TH FLOOR+/- 51'-0"
4TH FLOOR+/- 40'-0"
3RD FLOOR+/- 30'-0"
2ND FLOOR+/- 17'-0"
1ST FLOOR+/- 0'-0"
12TH FLOOR+/- 124'-0"
13TH FLOOR+/- 134'-0"
T.O.R.+/- 147'-10"
T.O.P.+/- 151'-2"
REMOVE EXISTING CAMERA TO BE REINSTALLED AFTER COMPLETION OF WORK. TYP.
REMOVE EXISTING STUCCO DOWN TO CUT STONE SUBSTRATE.
REMOVE EXISTING STATE SEAL. SET ASIDE, STORE AND PROTECT.
REMOVE EXISTINGEXTERIOR LIGHTING
FIXTURE. TYP.
METAL PLAQUE IS TO BE REMOVED AND STORED FOR REINSTALLATION.
REMOVE EXISTING FLAG SUPPORTS. STORE FOR REINSTALLATION. TYP.
EXISTING LOUVERS. TYP.
EXISTING/REMOVAL SOUTH ELEVATION Scale: 1/8" = 1'-0"1
0 10 20 30 40 50 FT
ABOVE 2ND FLOOR: REMOVE EXISTING STUCCO, FURRING, AND FRAMING DOWN TO FACE MASONRY.
BELOW 2ND FLOOR: REMOVE EXISTING STUCCO, FURRING, FRAMING AND THREE WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
2
2
2
REMOVAL LEGEND - ELEVATION
REMOVE EXISTING SILL, ASSOCIATED FLASHING, AND MASONRY BELOW.
REMOVE EXISTING LINTEL AND MASONRY ABOVE.REMOVE EXISTING MORTAR JOINTS IN BRICK, TERRA COTTA, AND CAST STONE TO 3/4" DEPTH MIN. OR TO SOUND MORTAR. REMOVE EXISTING FACE MASONRY.
REMOVE MORTAR AND STRIP/REMOVE ALL COATINGS AT EXISTING ARCHITECTURAL PRECAST CONCRETE FACADE AND PREPARE ARCHITECTURAL PRECAST CONCRETE FACADE FOR POINTING, PATCHING AND COATING.
ROUT OUT CRACKS AT EXISTING ARCHITECTURAL PRECAST CONCRETE.
REMOVE EXISTING STUCCO, FURRING, FRAMING AND ONE WYTHE OF MASONRY, EXCEPT WHERE OTHERWISE NOTED.
CUT AND PREPARE SPALL IN EXISTING ARCHITECTURAL PRECAST CONCRETE.
REMOVE/CUT OUT EXISTING TERRA COTTA UNIT.
REMOVE EXISTING PARAPET INCLUDING TWO WYTHES OF MASONRY ABOVE LINTEL AND THREE WYTHES AT THE SPANDREL LEVEL.
REMOVE EXISTING SKYLIGHT, LIGHTS, STOREFRONT, RAILING, METAL PLATES, ETC.
REMOVE FACE MASONRY, STUCCO AND MASONRY BACKUP FOR WINDOW OPENING.
REMOVE EXISTING METAL COVER, WINDOW, FRAME, PERIMETER SEALANT, ANCHORAGE, AND BLOCKING.
REMOVE EXISTING WINDOW, FRAME , BLACK-OUT PANEL, PERIMETER SEALANT, ANCHORAGE, AND BLOCKING.
REMOVE EXISTING DOOR AND FRAME.
REMOVE/CUT OUT EXISTING PRECAST CONCRETE FACADE, BRICK, AND MORTAR AND PREPARE SUBSTRATE FOR PRECAST CONCRETE FACADE PATCHING AND COATING.
REMOVE EXISTING COUNTER FLASHING AND SEALANT. REMOVE/CUT OUT EXISTING PRECAST CONCRETE FACADE AND PREPARE SUBSTRATE FOR PRECAST CONCRETE FACADE PATCHING AND COATING.
AT BULKHEADS REMOVE EXISTING PARAPET INCLUDING UP TO TWO WYTHES OF MASONRY NINE COURSES ABOVE ROOF SLAB.
LEGEND:2
REVISEDDRAWING -4/17/2019
EXISTING/REMOVAL WEST FACING SETBACK ELEVATION Scale: 1/8" = 1'-0"2
10TH FLOOR+/- 104'-0"
+/-1
7'-0
"+/
-13'
-0"
+/-1
0'-0
"+/
-11'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-6
"+/
-12'
-6"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
3'-1
0"+/
-3'-4
"
11TH FLOOR+/- 114'-0"
9TH FLOOR+/- 94'-0"
8TH FLOOR+/- 81'-6"
7TH FLOOR+/- 71'-0"
6TH FLOOR+/- 61'-0"
5TH FLOOR+/- 51'-0"
4TH FLOOR+/- 40'-0"
3RD FLOOR+/- 30'-0"
2ND FLOOR+/- 17'-0"
1ST FLOOR+/- 0'-0"
12TH FLOOR+/- 124'-0"
13TH FLOOR+/- 134'-0"
T.O.R.+/- 147'-10"
T.O.P.+/- 151'-2"
+/- 1
7'-8
"
REFER TO AREAWAY ELEVATIONS FOR SCOPE OF WORK.
EXISTINGMETAL CLADDINGTO REMAIN.
0 10 20 30 40 50 FT
1 01/16/2019 FINAL SUBMISSION
WARNING:
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THENEW YORK STATE EDUCATION LAW AND/OR REGULATIONS
ENGINEER FOR AN ENGINEER OR LANDSCAPE ARCHITECT
UNLESS DONE UNDER THE DIRECTION OF A COMPARABLE
AND IS A CLASS 'A' MISDEMEANOR.
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
THE ALTERATION OF THIS MATERIAL IN ANY WAY,
CLIENT:
CONTRACT:
TITLE:
LOCATION:
SHEET TITLE:
DESIGNED BY:
PROJECT
DRAWN BY:
DRAWING NUMBER:
FIELD CHECK:
APPROVED:
SHEET OF
MARK DATE DESCRIPTION
NUMBER:
REPAIR EXTERIOR FACADE
SHIRLEY CHISHOLM STATE OFFICE BLDG.55 HANSON PLACE
BROOKLYN, NY 11217
NEW YORK STATEOFFICE OF GENERAL SERVICES
44798
36x2
4 PL
OT
SHEE
T
CONSULTANT
May
04,
2017
- 10
:41a
m /V
olum
es/F
ile S
erve
r/PRO
JEC
T LI
ST c
urre
nt/1
7157
55
Han
son
Plac
e Ex
terio
r Reh
ab/1
7157
CAD
D/D.
1715
7 C
on D
oc -
Prog
ress
Set
s/Dr
awin
gTem
plat
es/G
-BS3
624.
dwg
- C
CONSTRUCTION
DESIGN & CONSTRUCTION
CTA ARCHITECTS P.C.
EXISTING / REMOVALELEVATION - EAST
A-007
SM
MJ / CT
APPROVED
SM HZ AR
2 04/17/2019 ADDENDUM 4
EXISTING/REMOVAL EAST ELEVATION Scale: 1/8" = 1'-0"1
GENERAL NOTES:
1. REFER TO ROOF PLAN AND BULKHEAD DRAWINGS FOR ADDITIONAL SCOPE.
2. AT ALL LOCATIONS OF ABATEMENT INCLUDE TEMPORARY PROTECTION TO MAINTAIN WATER TIGHTNESS.
REFER TO AREAWAYELEVATIONS, SHEET A-010, FOR
SCOPE. TYP.
REMOVE EXISTING CAMERA TO BE REINSTALLED AFTER COMPLETION OF WORK. TYP.
REMOVE EXISTING LIGHT FIXTURES, TYP.
10TH FLOOR+/- 104'-0"
+/-1
7'-0
"+/
-13'
-0"
+/-1
0'-0
"+/
-11'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-6
"+/
-12'
-6"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
3'-1
0"+/
-3'-4
"
11TH FLOOR+/- 114'-0"
9TH FLOOR+/- 94'-0"
8TH FLOOR+/- 81'-6"
7TH FLOOR+/- 71'-0"
6TH FLOOR+/- 61'-0"
5TH FLOOR+/- 51'-0"
4TH FLOOR+/- 40'-0"
3RD FLOOR+/- 30'-0"
2ND FLOOR+/- 17'-0"
1ST FLOOR+/- 0'-0"
12TH FLOOR+/- 124'-0"
13TH FLOOR+/- 134'-0"
T.O.R.+/- 147'-10"
T.O.P.+/- 151'-2"
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
2
2
2 2
REMOVAL LEGEND - ELEVATION
REMOVE EXISTING SILL, ASSOCIATED FLASHING, AND MASONRY BELOW.
REMOVE EXISTING LINTEL AND MASONRY ABOVE.REMOVE EXISTING MORTAR JOINTS IN BRICK, TERRA COTTA, AND CAST STONE TO 3/4" DEPTH MIN. OR TO SOUND MORTAR. REMOVE EXISTING FACE MASONRY.
REMOVE MORTAR AND STRIP/REMOVE ALL COATINGS AT EXISTING ARCHITECTURAL PRECAST CONCRETE FACADE AND PREPARE ARCHITECTURAL PRECAST CONCRETE FACADE FOR POINTING, PATCHING AND COATING.
ROUT OUT CRACKS AT EXISTING ARCHITECTURAL PRECAST CONCRETE.
REMOVE EXISTING STUCCO, FURRING, FRAMING AND ONE WYTHE OF MASONRY, EXCEPT WHERE OTHERWISE NOTED.
CUT AND PREPARE SPALL IN EXISTING ARCHITECTURAL PRECAST CONCRETE.
REMOVE/CUT OUT EXISTING TERRA COTTA UNIT.
REMOVE EXISTING PARAPET INCLUDING TWO WYTHES OF MASONRY ABOVE LINTEL AND THREE WYTHES AT THE SPANDREL LEVEL.
REMOVE EXISTING SKYLIGHT, LIGHTS, STOREFRONT, RAILING, METAL PLATES, ETC.
REMOVE FACE MASONRY, STUCCO AND MASONRY BACKUP FOR WINDOW OPENING.
REMOVE EXISTING METAL COVER, WINDOW, FRAME, PERIMETER SEALANT, ANCHORAGE, AND BLOCKING.
REMOVE EXISTING WINDOW, FRAME , BLACK-OUT PANEL, PERIMETER SEALANT, ANCHORAGE, AND BLOCKING.
REMOVE EXISTING DOOR AND FRAME.
REMOVE/CUT OUT EXISTING PRECAST CONCRETE FACADE, BRICK, AND MORTAR AND PREPARE SUBSTRATE FOR PRECAST CONCRETE FACADE PATCHING AND COATING.
REMOVE EXISTING COUNTER FLASHING AND SEALANT. REMOVE/CUT OUT EXISTING PRECAST CONCRETE FACADE AND PREPARE SUBSTRATE FOR PRECAST CONCRETE FACADE PATCHING AND COATING.
AT BULKHEADS REMOVE EXISTING PARAPET INCLUDING UP TO TWO WYTHES OF MASONRY NINE COURSES ABOVE ROOF SLAB.
LEGEND:
2 2
REVISEDDRAWING -4/17/2019
REMOVAL LEGEND - ELEVATION
REMOVE EXISTING SILL, ASSOCIATED FLASHING, AND MASONRY BELOW.
REMOVE EXISTING LINTEL AND MASONRY ABOVE.REMOVE EXISTING MORTAR JOINTS IN BRICK, TERRA COTTA, AND CAST STONE TO 3/4" DEPTH MIN. OR TO SOUND MORTAR. REMOVE EXISTING FACE MASONRY.
REMOVE MORTAR AND STRIP/REMOVE ALL COATINGS AT EXISTING ARCHITECTURAL PRECAST CONCRETE FACADE AND PREPARE ARCHITECTURAL PRECAST CONCRETE FACADE FOR POINTING, PATCHING AND COATING.
ROUT OUT CRACKS AT EXISTING ARCHITECTURAL PRECAST CONCRETE.
REMOVE EXISTING STUCCO, FURRING, FRAMING AND ONE WYTHE OF MASONRY, EXCEPT WHERE OTHERWISE NOTED.
CUT AND PREPARE SPALL IN EXISTING ARCHITECTURAL PRECAST CONCRETE.
REMOVE/CUT OUT EXISTING TERRA COTTA UNIT.
REMOVE EXISTING PARAPET INCLUDING TWO WYTHES OF MASONRY ABOVE LINTEL AND THREE WYTHES AT THE SPANDREL LEVEL.
REMOVE EXISTING SKYLIGHT, LIGHTS, STOREFRONT, RAILING, METAL PLATES, ETC.
REMOVE FACE MASONRY, STUCCO AND MASONRY BACKUP FOR WINDOW OPENING.
REMOVE EXISTING METAL COVER, WINDOW, FRAME, PERIMETER SEALANT, ANCHORAGE, AND BLOCKING.
REMOVE EXISTING WINDOW, FRAME , BLACK-OUT PANEL, PERIMETER SEALANT, ANCHORAGE, AND BLOCKING.
REMOVE EXISTING DOOR AND FRAME.
REMOVE/CUT OUT EXISTING PRECAST CONCRETE FACADE, BRICK, AND MORTAR AND PREPARE SUBSTRATE FOR PRECAST CONCRETE FACADE PATCHING AND COATING.
REMOVE EXISTING COUNTER FLASHING AND SEALANT. REMOVE/CUT OUT EXISTING PRECAST CONCRETE FACADE AND PREPARE SUBSTRATE FOR PRECAST CONCRETE FACADE PATCHING AND COATING.
AT BULKHEADS REMOVE EXISTING PARAPET INCLUDING UP TO TWO WYTHES OF MASONRY NINE COURSES ABOVE ROOF SLAB.
LEGEND:
2 2
1 01/16/2019 FINAL SUBMISSION
WARNING:
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THENEW YORK STATE EDUCATION LAW AND/OR REGULATIONS
ENGINEER FOR AN ENGINEER OR LANDSCAPE ARCHITECT
UNLESS DONE UNDER THE DIRECTION OF A COMPARABLE
AND IS A CLASS 'A' MISDEMEANOR.
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
THE ALTERATION OF THIS MATERIAL IN ANY WAY,
CLIENT:
CONTRACT:
TITLE:
LOCATION:
SHEET TITLE:
DESIGNED BY:
PROJECT
DRAWN BY:
DRAWING NUMBER:
FIELD CHECK:
APPROVED:
SHEET OF
MARK DATE DESCRIPTION
NUMBER:
REPAIR EXTERIOR FACADE
SHIRLEY CHISHOLM STATE OFFICE BLDG.55 HANSON PLACE
BROOKLYN, NY 11217
NEW YORK STATEOFFICE OF GENERAL SERVICES
44798
36x2
4 PL
OT
SHEE
T
CONSULTANT
May
04,
2017
- 10
:41a
m /V
olum
es/F
ile S
erve
r/PRO
JEC
T LI
ST c
urre
nt/1
7157
55
Han
son
Plac
e Ex
terio
r Reh
ab/1
7157
CAD
D/D.
1715
7 C
on D
oc -
Prog
ress
Set
s/Dr
awin
gTem
plat
es/G
-BS3
624.
dwg
- C
CONSTRUCTION
DESIGN & CONSTRUCTION
CTA ARCHITECTS P.C.
EXISTING / REMOVALELEVATION - NORTH
A-008
SM
MJ / CT
SM HZ AR
APPROVED
2 04/17/2019 ADDENDUM 4
EXISTING/REMOVAL NORTH ELEVATION Scale: 1/8" = 1'-0"1
ADJACENTBUILDING
GENERAL NOTES: 1. REFER TO ROOF PLAN AND BULKHEAD DRAWINGS FOR ADDITIONAL SCOPE.
2. AT ALL LOCATIONS OF ABATEMENT INCLUDE TEMPORARY PROTECTION TO MAINTAIN WATER TIGHTNESS.
DETACH EXISTING METAL GATE AND PROTECT.
EXISTINGSKYLIGHT AND
GLAZING SYSTEMTO BE REMOVED.
EXISTINGMETAL CLADDINGTO REMAIN.
REFER TO AREAWAYELEVATIONS, SHEET A-010, FOR
SCOPE. TYP.
REMOVE EXISTING CAMERA TO BE REINSTALLED AFTER COMPLETION OF WORK. TYP.
REMOVE EXISTING CAMELBACKCOPING STONE. REFER TO ROOF
AND REAR YARD DRAWINGS.
REMOVE EXISTING LIGHT FIXTURES, TYP.
10TH FLOOR+/- 104'-0"
+/- 1
7'-0
"+/
- 13'
-0"
+/- 1
0'-0
"+/
- 11'
-0"
+/- 1
0'-0
"+/
- 10'
-0"
+/- 1
0'-6
"+/
- 12'
-6"
+/- 1
0'-0
"+/
- 10'
-0"
+/- 1
0'-0
"+/
- 10'
-0"
+/- 1
3'-1
0"+/
- 3'-4
"
11TH FLOOR+/- 114'-0"
9TH FLOOR+/- 94'-0"
8TH FLOOR+/- 81'-6"
7TH FLOOR+/- 71'-0"
6TH FLOOR+/- 61'-0"
5TH FLOOR+/-51'-0"
3RD FLOOR+/- 30'-0"
2ND FLOOR+/- 17'-0"
1ST FLOOR+/- 0'-0"
12TH FLOOR+/- 124'-0"
13TH FLOOR+/- 134'-0"
T.O.R.+/- 147'-10"
T.O.P.+/- 151'-2"
4TH FLOOR+/- 40'-0"
DETACH EXISTING METAL GATE AND PROTECT.
4
A-011
0 10 20 30 FT
ADJACENTBUILDING
SHED
ADJACENTBUILDING
DECK ANDSTAIRSADJACENT
BUILDING ENTRANCE STAIRS
EXISTING E.J.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
2
2
2
2
2
REVISEDDRAWING -4/17/2019
REMOVAL LEGEND - ELEVATION
REMOVE EXISTING SILL, ASSOCIATED FLASHING, AND MASONRY BELOW.
REMOVE EXISTING LINTEL AND MASONRY ABOVE.REMOVE EXISTING MORTAR JOINTS IN BRICK, TERRA COTTA, AND CAST STONE TO 3/4" DEPTH MIN. OR TO SOUND MORTAR. REMOVE EXISTING FACE MASONRY.
REMOVE MORTAR AND STRIP/REMOVE ALL COATINGS AT EXISTING ARCHITECTURAL PRECAST CONCRETE FACADE AND PREPARE ARCHITECTURAL PRECAST CONCRETE FACADE FOR POINTING, PATCHING AND COATING.
ROUT OUT CRACKS AT EXISTING ARCHITECTURAL PRECAST CONCRETE.
REMOVE EXISTING STUCCO, FURRING, FRAMING AND ONE WYTHE OF MASONRY, EXCEPT WHERE OTHERWISE NOTED.
CUT AND PREPARE SPALL IN EXISTING ARCHITECTURAL PRECAST CONCRETE.
REMOVE/CUT OUT EXISTING TERRA COTTA UNIT.
REMOVE EXISTING PARAPET INCLUDING TWO WYTHES OF MASONRY ABOVE LINTEL AND THREE WYTHES AT THE SPANDREL LEVEL.
REMOVE EXISTING SKYLIGHT, LIGHTS, STOREFRONT, RAILING, METAL PLATES, ETC.
REMOVE FACE MASONRY, STUCCO AND MASONRY BACKUP FOR WINDOW OPENING.
REMOVE EXISTING METAL COVER, WINDOW, FRAME, PERIMETER SEALANT, ANCHORAGE, AND BLOCKING.
REMOVE EXISTING WINDOW, FRAME , BLACK-OUT PANEL, PERIMETER SEALANT, ANCHORAGE, AND BLOCKING.
REMOVE EXISTING DOOR AND FRAME.
REMOVE/CUT OUT EXISTING PRECAST CONCRETE FACADE, BRICK, AND MORTAR AND PREPARE SUBSTRATE FOR PRECAST CONCRETE FACADE PATCHING AND COATING.
REMOVE EXISTING COUNTER FLASHING AND SEALANT. REMOVE/CUT OUT EXISTING PRECAST CONCRETE FACADE AND PREPARE SUBSTRATE FOR PRECAST CONCRETE FACADE PATCHING AND COATING.
AT BULKHEADS REMOVE EXISTING PARAPET INCLUDING UP TO TWO WYTHES OF MASONRY NINE COURSES ABOVE ROOF SLAB.
LEGEND:
2 2
EXISTING/REMOVAL WEST ELEVATION Scale: 1/8" = 1'-0"1
GENERAL NOTES:
1. REFER TO ROOF PLAN AND BULKHEAD DRAWINGS FOR ADDITIONAL SCOPE.
2. AT ALL LOCATIONS OF ABATEMENT INCLUDE TEMPORARY PROTECTION TO MAINTAIN WATER TIGHTNESS.
REFER TO AREAWAYELEVATIONS, SHEET A-010, FOR
SCOPE. TYP.
REMOVE EXISTING CAMERA TO BE REINSTALLED AFTER COMPLETION OF WORK. TYP.
REMOVE EXISTING LIGTH FIXTURES, TYP.
EXISTING SIDEWALK SHED.
5
A-021 0 10 20 30 40 50 FT
10TH FLOOR+/- 104'-0"
+/-1
7'-0
"+/
-13'
-0"
+/-1
0'-0
"+/
-11'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-6
"+/
-12'
-6"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
3'-1
0"+/
-3'-4
"
11TH FLOOR+/- 114'-0"
9TH FLOOR+/- 94'-0"
8TH FLOOR+/- 81'-6"
7TH FLOOR+/- 71'-0"
6TH FLOOR+/- 61'-0"
5TH FLOOR+/- 51'-0"
4TH FLOOR+/- 40'-0"
3RD FLOOR+/- 30'-0"
2ND FLOOR+/- 17'-0"
1ST FLOOR+/- 0'-0"
12TH FLOOR+/- 124'-0"
13TH FLOOR+/- 134'-0"
T.O.R.+/- 147'-10"
T.O.P.+/- 151'-2"
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
AT BAND: REMOVE EXISTING STUCCO, FURRING, FRAMING AND TWO WHYTHES OF MASONRY.
2
2
2
1 01/16/2019 FINAL SUBMISSION
WARNING:
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THENEW YORK STATE EDUCATION LAW AND/OR REGULATIONS
ENGINEER FOR AN ENGINEER OR LANDSCAPE ARCHITECT
UNLESS DONE UNDER THE DIRECTION OF A COMPARABLE
AND IS A CLASS 'A' MISDEMEANOR.
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
THE ALTERATION OF THIS MATERIAL IN ANY WAY,
CLIENT:
CONTRACT:
TITLE:
LOCATION:
SHEET TITLE:
DESIGNED BY:
PROJECT
DRAWN BY:
DRAWING NUMBER:
FIELD CHECK:
APPROVED:
SHEET OF
MARK DATE DESCRIPTION
NUMBER:
REPAIR EXTERIOR FACADE
SHIRLEY CHISHOLM STATE OFFICE BLDG.55 HANSON PLACE
BROOKLYN, NY 11217
NEW YORK STATEOFFICE OF GENERAL SERVICES
44798
36x2
4 PL
OT
SHEE
T
CONSULTANT
May
04,
2017
- 10
:41a
m /V
olum
es/F
ile S
erve
r/PRO
JEC
T LI
ST c
urre
nt/1
7157
55
Han
son
Plac
e Ex
terio
r Reh
ab/1
7157
CAD
D/D.
1715
7 C
on D
oc -
Prog
ress
Set
s/Dr
awin
gTem
plat
es/G
-BS3
624.
dwg
- C
CONSTRUCTION
DESIGN & CONSTRUCTION
CTA ARCHITECTS P.C.
EXISTING / REMOVALELEVATION - WEST
A-009
SM
MJ / CT
APPROVED
SM HZ AR
2
2 04/17/2019 ADDENDUM 4
EXISTING/REMOVAL EAST FACING SETBACK ELEVATION Scale: 1/8" = 1'-0"2
10TH FLOOR+/-104'-0"
+/-1
7'-0
"+/
-13'
-0"
+/-1
0'-0
"+/
-11'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-6
"+/
-12'
-6"
+/-1
0'-0
"+/
-10'
-0"
+/-1
0'-0
"+/
-10'
-0"
+/-1
3'-1
0"+/
-3'-4
"
11TH FLOOR+/- 114'-0"
9TH FLOOR+/- 94'-0"
8TH FLOOR+/- 81'-6"
7TH FLOOR+/- 71'-0"
6TH FLOOR+/- 61'-0"
5TH FLOOR+/- 51'-0"
4TH FLOOR+/- 40'-0"
3RD FLOOR+/- 30'-0"
2ND FLOOR+/- 17'-0"
1ST FLOOR+/- 0'-0"
12TH FLOOR+/- 124'-0"
13TH FLOOR+/- 134'-0"
T.O.R.+/- 147'-10"
T.O.P.+/- 151'-2"
REVISEDDRAWING -4/17/2019
1 01/16/2019 FINAL SUBMISSION
WARNING:
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THENEW YORK STATE EDUCATION LAW AND/OR REGULATIONS
ENGINEER FOR AN ENGINEER OR LANDSCAPE ARCHITECT
UNLESS DONE UNDER THE DIRECTION OF A COMPARABLE
AND IS A CLASS 'A' MISDEMEANOR.
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
THE ALTERATION OF THIS MATERIAL IN ANY WAY,
CLIENT:
CONTRACT:
TITLE:
LOCATION:
SHEET TITLE:
DESIGNED BY:
PROJECT
DRAWN BY:
DRAWING NUMBER:
FIELD CHECK:
APPROVED:
SHEET OF
MARK DATE DESCRIPTION
NUMBER:
REPAIR EXTERIOR FACADE
SHIRLEY CHISHOLM STATE OFFICE BLDG.55 HANSON PLACE
BROOKLYN, NY 11217
NEW YORK STATEOFFICE OF GENERAL SERVICES
44798
36x2
4 PL
OT
SHEE
T
CONSULTANT
May
04,
2017
- 10
:41a
m /V
olum
es/F
ile S
erve
r/PRO
JEC
T LI
ST c
urre
nt/1
7157
55
Han
son
Plac
e Ex
terio
r Reh
ab/1
7157
CAD
D/D.
1715
7 C
on D
oc -
Prog
ress
Set
s/Dr
awin
gTem
plat
es/G
-BS3
624.
dwg
- C
CONSTRUCTION
DESIGN & CONSTRUCTION
CTA ARCHITECTS P.C.
EXISTING / REMOVALBULKHEAD ELEVATIONS
A-011
NP
NP
MJ CT
2 04/17/2019 ADDENDUM 4
16'-5" +/-11'-5" +/-
8'-6
" +/
-
11'-5" +/-
17'-10" +/-
1'-1
0" +
/-
3'-6
" +/
-
13'-7" +/- 3'-1" +/- 1'-6" +/-
8'-6
" +/
-
EXIST. ROOF
EXIST. ROOF
WEST ELEVATION STAIRWAY AScale: 1/8" = 1'-0"1 SOUTH ELEVATION STAIRWAY A
Scale: 1/8" = 1'-0"2 EAST ELEVATION STAIRWAY AScale: 1/8" = 1'-0"3
SHEET NOTES:
1. DISCONNECT AND TEMPORARILY REMOVE AND STORE ELECTRICAL CONDUIT, WIRES / CABLES, ANTENNAS TO COMPLETE WORK.
2. TEMPORARILY REMOVE AND STORE BULKHEAD DOORS, FRAMES AND HARDWARE TO COMPLETE WORK.
EXISTING COUNTER FLASHING TO BE REMOVED, (TYP).
EXISTING METALSCUPPER, SPLASH
PAD AND 2 SQUAREFEET MASONRY TO BE
REMOVED, (TYP).
NORTH ELEVATION STAIRWAY AScale: 1/8" = 1'-0"4
REMOVE EXISTINGLIGHT FIXTURE.
REMOVE EXISTINGRECEPTACLE
CONDUIT.
2
30'-7" +/-
18'-5
" +/
-
15'-11" +/-10
'-1"
+/-
8'-5
" +/
-15'-11" +/-
30'-7" +/-
18'-5
" +/
-
15'-11" +/-
10'-1
" +/
-8'
-5"
+/-
15'-11" +/-
20'-11" +/-
28'-1
" +/
-
7'-5" +/- 17'-6" +/- 10'-2" +/- 9" +/- 9'-6" +/- 12'-10" +/-
51'-6" +/-
12'-1
1" +
/-
16'-8
" +/-
9'-8
" +/
-
20'-3
" +/
-
1'-0
" +/-
7'-1
0" +
/-
9" +/- 20'-11" +/- 2'-3" +/-
37'-2" +/- 12'-11" +/-12'-11" +/-
10'-1
0" +
/-
8'-8
" +/
-
37'-2" +/-12'-11" +/- 12'-11" +/-
10'-1
0" +
/-
8'-8
" +/
-
31'-4" +/-
31'-4" +/-
16'-0" +/-8'-0" +/- 8'-0" +/-
8" +/-
16'-0" +/- 8'-0" +/-8'-0" +/-
8" +/-
8'-7
" +/
-
7'-3" +/-
8'-7
" +/
-
7'-3" +/-
9'-2
" +/
-
7" +
/-
28'-5" +/-
2'-8
" +/
-
2'-8
" +/
-
2'-8
" +/-
2'-8
" +/-
2'-8
" +/
-
2'-8
" +/
-
3'-6
" +/-
2'-5
" +/-
20'-1" +/-
9'-2
" +/
-
28'-5" +/-
10'-6" +/- 1'-11" +/-
18'-5
" +/
-
10'-6" +/-
18'-5
" +/
-
17'-6" +/-11'-0" +/-10'-3" +/-4'-6" +/-
6" +/-
4'-1" +/-4'-6" +/-
2'-4
" +/-
5'-0
" +/
-
3'-4
" +/
-
2'-6
" +/
-
2'-4
" +/
-
20'-3
" +/
-7'
-10"
+/-
EXIST. ROOF
EXIST. ROOF
EXIST. ROOF
EXIST. ROOF
EXIST. ROOF
20'-1" +/-
1'-11" +/-
7'-0
" +/
-15'-9
" +/-
7'-6
" +/
-
7'-0
" +/
-
7'-6
" +/
-
NORTH ELVATION SHEDScale: 1/8" = 1'-0"14
WEST ELEVATION SHEDScale: 1/8" = 1'-0"15 SOUTH ELEVATION SHED
Scale: 1/8" = 1'-0"16
SOUTH ELEVATION STAIRWAY B & BH1Scale: 1/8" = 1'-0"5 EAST ELEVATION STAIRWAY B & BH1
Scale: 1/8" = 1'-0"6 NORTH ELEVATION STAIRWAY B & BH1Scale: 1/8" = 1'-0"7
NORTH ELEVATION STAIRWAY C & BH2Scale: 1/8" = 1'-0"9 WEST ELEVATION STAIRWAY C & BH2
Scale: 1/8" = 1'-0"10 SOUTH ELEVATION STAIRWAY C & BH2Scale: 1/8" = 1'-0"11
WEST ELEVATION STAIRWAY D, BH3, BH4, BH5 & BH6Scale: 1/8" = 1'-0"17 SOUTH ELEVATION STAIRWAY D, BH3, BH4, BH5 & BH6
Scale: 1/8" = 1'-0"18 EAST ELEVATION STAIRWAY D, BH3, BH4, BH5 & BH6Scale: 1/8" = 1'-0"19 EAST ELEVATION ELEVATOR BH
Scale: 1/8" = 1'-0"21
SOUTH ELEVATION ELEVATOR BHScale: 1/8" = 1'-0"22 NORTH ELEVATION ELEVATOR BH
Scale: 1/8" = 1'-0"23 WEST ELEVATION ELEVATOR BHScale: 1/8" = 1'-0"24
REMOVE CLADDING &FRAME OPENINGFOR FABRICATED
DOOR
REMOVE & CLOSE UP DOOR OPENING WITH METAL CLADDING SYSTEM
REMOVE EXISTING CLADDING AT SHED
REMOVE EXIST. WALL OPENING
REMOVE EXIST. LADDERS
REMOVE EXIST. STAIRS
EXISTINGGUTTER ANDDOWNSPOUT
TO REMAIN
REMOVE 30SF+/- OF EXIST. WALL OPENING FOR CONDENSER DUCTWORKRECONFIGURATION PER MECHANICAL DRAWINGS. TEMPORARY SHORING
INSTALLED AS REQUIRED
REMOVE EXISTING LIGHT FIXTURE.
CONDUIT.
EXISTING GUTTER& DOWNSPOUT
TO BE REMOVED,(TYP).
EXISTING METAL SCUPPER, SPLASH PAD AND 2 SQUARE FEET MASONRY TO BE REMOVED.
CONDUIT.
EAST ELEVATION STAIRWAY C & BH2Scale: 1/8" = 1'-0"12
NORTH ELEVATION STAIRWAY D, BH3, BH4, BH5 & BH6Scale: 1/8" = 1'-0"20
EXISTING COUNTER FLASHING TO BE REMOVED AT ELEVATOR BULKHEAD BUT NOT RAISED, (TYP).
EXIST. MTL CLADDING TO REMAIN. TYP.
REMOVE METAL CLADDING AND EXPANSION JOINTS, (TYP).
EXHAUST FANS TO BE REINSTALLED ON RAISEDCURB. REMOVE ROOF MEMBRANE AND
FLASHING AND PREPARE CURB TO BE PRIMED.TEMPORARILY DISCONNECT AND REMOVE
EXHAUST FAN UNITS & REINSTALL TOCOMPLETE FUNCTION PER MECHANICAL
DRAWINGS, (TYP).
EXISTING ELEVATORBULKHEAD DOOR TO
REMAIN
EXISTINGSTAIRTOWER TO
REMAIN
REMOVE EXISTING SKYLIGHT. SEE SKYLIGHT REMOVAL DRAWINGS FOR ADDITIONAL NOTES
REMOVE EXISTING WALL VENTS.
EXISTING METAL SCUPPER,SPLASH PAD AND 2 SQUARE FEET
MASONRY TO BE REMOVED.
EAST ELEVATION SHEDScale: 1/8" = 1'-0"13
WEST ELEVATION STAIRWAY B & BH1Scale: 1/8" = 1'-0"8
0 5 10 15 20 25 FT
BULKHEAD 1TO BE
REMOVED(TYP).
REMOVEEXISTING
DOOR.
BULKHEAD 2 TO BE REMOVED (TYP).
REMOVE EXISTING DOOR.
CONDUIT.
REMOVE EXISTING LIGHT FIXTURE.
REMOVE EXISTING LIGHT FIXTURE.
CONDUIT.
REMOVE EXISTING LIGHT FIXTURE.
CONDUIT.
RECEPTACLE.
REMOVE EXISTING RECEPTACLE.
REMOVE EXISTING RECEPTACLE.
REMOVE EXISTING LIGHT FIXTURE.
CONDUIT.
REMOVE ALL EXISTING PRECAST, CAMELBACK AND METAL COPINGS/GRAVEL STOPS.
REMOVE FAILING COATING AND PREPARE EXISTING STUCCO FOR COATING
REMOVE EXISTING WINDOW, PERIMETER SEALANT, AND EXISTING WINDOW ANCHORAGE.
REMOVE EXISTING DOOR SILL AND ASSOCIATED FLASHING.
REMOVE MASONRY AND STUCCO AT EXISTING CRACKS
CUT AND PREPARE SPALL IN EXISTING CAST STONE.
ROUT OUT CRACKS AND MORTAR EXISTING CAST STONE AND MASONRY
REMOVE EXISTING DOOR HEAD WALL CONFIGURATION, LINTEL/SPANDREL AND ASSOCIATED FLASHING.
REMOVE EXISTING MORTAR JOINTS IN BRICK AND TERRA COTTA.
REMOVE EXISTING FACE MASONRY.
REMOVE FULL WIDTH OF PARAPET
REMOVE EXISTING LIGHTREMOVE EXISTING METAL CLADDING.
AT BULKHEADS REMOVE EXISTING PARAPET INCLUDING UP TO TWO WYTHES OF MASONRY NINE COURSES ABOVE ROOF SLAB.
LEGEND:
2
REVISED DRAWING - 4/17/2019
1 01/16/2019 FINAL SUBMISSION
WARNING:
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THENEW YORK STATE EDUCATION LAW AND/OR REGULATIONS
ENGINEER FOR AN ENGINEER OR LANDSCAPE ARCHITECT
UNLESS DONE UNDER THE DIRECTION OF A COMPARABLE
AND IS A CLASS 'A' MISDEMEANOR.
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
THE ALTERATION OF THIS MATERIAL IN ANY WAY,
CLIENT:
CONTRACT:
TITLE:
LOCATION:
SHEET TITLE:
DESIGNED BY:
PROJECT
DRAWN BY:
DRAWING NUMBER:
FIELD CHECK:
APPROVED:
SHEET OF
MARK DATE DESCRIPTION
NUMBER:
REPAIR EXTERIOR FACADE
SHIRLEY CHISHOLM STATE OFFICE BLDG.55 HANSON PLACE
BROOKLYN, NY 11217
NEW YORK STATEOFFICE OF GENERAL SERVICES
44798
36x2
4 PL
OT
SHEE
T
CONSULTANT
May
04,
2017
- 10
:41a
m /V
olum
es/F
ile S
erve
r/PRO
JEC
T LI
ST c
urre
nt/1
7157
55
Han
son
Plac
e Ex
terio
r Reh
ab/1
7157
CAD
D/D.
1715
7 C
on D
oc -
Prog
ress
Set
s/Dr
awin
gTem
plat
es/G
-BS3
624.
dwg
- C
CONSTRUCTION
DESIGN & CONSTRUCTION
CTA ARCHITECTS P.C.
BULKHEAD ELEVATIONS
A-206
NP
NP
MJ CT
2 04/17/2019 ADDENDUM 4
8" +
/-
8" +
/-
8" +
/-
16'-5" +/-11'-5" +/- 11'-5" +/-
9'-1
" +/
-
20'-11" +/-
26'-7
" +/-
7'-5" +/- 17'-6" +/- 10'-2" +/- 9" +/- 9'-6" +/- 12'-10" +/-
51'-6" +/-
11'-4
" +/
-
15'-2
" +/-
8'-2
" +/
-
18'-9
" +/
-
1'-0
" +/
-7'-1
0" +
/-
9" +/- 20'-11" +/- 2'-3" +/-
37'-2" +/- 31'-4" +/-31'-4" +/-
7'-1
" +/
-
7'-3" +/-
7'-1
" +/-
7'-3" +/-
7'-8
" +/
-
7" +
/-
28'-5" +/-
17'-10" +/-
VARIES PER ROOF HEIGHT
VARIES PER ROOF HEIGHT
6'-1
0" +
/-
8" +
/-
8" +
/- 8
" +/-
VARIES PER ROOF HEIGHT
8" +
/-
VARIES PERROOF
HEIGHT
VARIES PER ROOF HEIGHT
VARIES PERROOF
HEIGHT
8" +
/- 8" +
/-
8" +
/-
VARIES PER ROOF HEIGHT
VARIES PER ROOF HEIGHT
VARIES PER ROOF HEIGHT
13'-7" +/- 3'-1" +/- 1'-6" +/-
11'-6" +/-
VARIES PER ROOF HEIGHT
28'-5" +/-
17'-6" +/-11'-0" +/-10'-3" +/-4'-6" +/-
6" +/-
4'-1" +/-4'-6" +/-
2'-4
" +/
-
5'-8
" +/-
3'-4
" +/
-
2'-6
" +/
-
2'-4
" +/-
VARIES PER ROOF HEIGHT
37'-2" +/- 12'-11" +/-12'-11" +/-
10'-3
" +/-
8'-1
" +/-
EXIST. ROOF
RAISED ROOF
EXIST. ROOFRAISED ROOF
EXIST. ROOFRAISED ROOF
EXIST. ROOFRAISED ROOF
EXIST. ROOFRAISED ROOF
EXIST. ROOFRAISED ROOF
EXIST. ROOFRAISED ROOF
E.J. E.J.
10'-7
" +/-
11'-6" +/-
8" +
/-
11'-6" +/-
8" +
/-
11'-6" +/-
VARIES PERROOF
HEIGHT
WEST ELEVATION STAIRWAY AScale: 1/8" = 1'-0"1 SOUTH ELEVATION STAIRWAY A
Scale: 1/8" = 1'-0"2 EAST ELEVATION STAIRWAY AScale: 1/8" = 1'-0"3
NORTH ELEVATION SHEDScale: 1/8" = 1'-0"14
WEST ELEVATION SHEDScale: 1/8" = 1'-0"15 SOUTH ELEVATION SHED
Scale: 1/8" = 1'-0"16
SOUTH ELEVATION STAIRWAY BScale: 1/8" = 1'-0"5
EAST ELEVATION @ STAIRWAY BScale: 1/8" = 1'-0"6 NORTH ELEVATION STAIRWAY B
Scale: 1/8" = 1'-0"7
NORTH ELEVATION STAIRWAY CScale: 1/8" = 1'-0"9 WEST ELEVATION STAIRWAY C
Scale: 1/8" = 1'-0"10 SOUTH ELEVATION STAIRWAY CScale: 1/8" = 1'-0"11
WEST ELEVATION STAIRWAY D, BH3, BH4, BH5 & BH6Scale: 1/8" = 1'-0"17 SOUTH ELEVATION STAIRWAY D, BH3, BH4, BH5 & BH6
Scale: 1/8" = 1'-0"18 EAST ELEVATION STAIRWAY D, BH3, BH4, BH5 & BH6Scale: 1/8" = 1'-0"19
EAST ELEVATION ELEVATOR BHScale: 1/8" = 1'-0"24SOUTH ELEVATION ELEVATOR BH
Scale: 1/8" = 1'-0"21 NORTH ELEVATION ELEVATOR BHScale: 1/8" = 1'-0"22 WEST ELEVATION ELEVATOR BH
Scale: 1/8" = 1'-0"23
SHEET NOTES:
1. REINSTALL SALVAGED BULKHEAD DOORS, FRAMES AND HARDWARE, ON RAISED SILLS PER RAISED ROOF HEIGHT. INSTALL DOOR AT SHED PER MANUFACTURER'S REQUIREMENTS. DOOR AT ELEVATOR BULKHEAD TO REMAIN. DOORS AT BULKHEADS TO BE PREPARED, PRIMED, AND PAINTED.
2. PROVIDE METAL SCUPPERS , GUTTERS, DOWNSPOUTS AND SPLASH PADS.
3. REATTACH WIRES/CABLES TO CLADDING ON BULKHEADS AS PER ELECTRICAL DRAWINGS , MIN. 18" ABOVE ROOF TRAFFIC SURFACE.
4. PROVIDE ACCESS LADDER SHOP DRAWINGS. TYP.
5. PROVIDE NYS CODE COMPLIANT TOP MOUNTED GALVANIZED STEEL HANDRAIL (+/- 475' LINEAR FEET TOTAL), RAILINGS, PICKETS, AND ANCHOR PLATE 42 INCHES MIN. ABOVE ROOF TRAFFIC SURFACE. PER SHOP DRAWINGS.
6. PATCH OPENINGS AT REMOVED ELECTRICAL DEVICES AND CONDUITS AT BULKHEAD WALLS.
PROVIDE RELOCATED DOOR/FRAME
MODIFY AND REINSTALL MTL CLADDING @ SHED.
PROVIDE METAL LADDERS
PROVIDE EXTENDED METALSTAIRS AND RAILING
PROVIDE GUTTER, DOWNSPOUTAND SPLASHPAD
PROVIDE GUTTER, DOWNSPOUT AND SPLASHPAD
EXIST. MTL CLADDING TO REMAIN @ BH3
EXIST. MTLCLADDING TO
REMAIN @ BH3
INSTALL RAISED COUNTER FLASHING TO ALLOW 8” FROM FINISHED ROOF TO TOP OF COUNTER FLASHING
INSTALL RAISEDCOUNTER FLASHING TO
ALLOW 8” FROMFINISHED ROOF TO TOPOF COUNTER FLASHING
LIGHT FIXTURES, CONDUIT AND JUNCTION BOXES.
LIGHT FIXTURE.
LIGHT FIXTURE AND CONDUIT.
JUNCTION BOXES.
RAISED METAL SCUPPER,SPLASH PAD AND 2 SQUARE
FEET MASONRY.
RAISED METALSCUPPER,
SPLASH PADAND 2 SQUARE
FEETMASONRY.
PROVIDE RAIL AT42” MIN. ABOVE
FINISHED FLOOR.REFER TO SHEET
A-518.
INSTALL RAISED COUNTER FLASHING TO ALLOW 8” FROM FINISHED ROOF TO TOP OF COUNTER FLASHING
LIGHT FIXTURES, CONDUIT AND JUNCTION BOXES.
PROVIDE RAIL AT 42” MIN. ABOVE FINISHED FLOOR. REFER TO SHEET A-518.
PROVIDE RAILAT 42” MIN.
ABOVEFINISHED
ROOF. REFERTO SHEET
A-518.
INSTALL RAISED COUNTERFLASHING TO ALLOW 8”
FROM FINISHED ROOF TOTOP OF COUNTER
FLASHING
LIGHT FIXTURES,CONDUIT AND
JUNCTION BOXES.
INSTALL RAISEDCOUNTER
FLASHING TOALLOW 8” FROM
FINISHED ROOF TOTOP OF COUNTER
FLASHING
PROVIDE RAIL AT 42” MIN. ABOVE FINISHED FLOOR. REFER TO SHEET A-518.
PROVIDE GUTTER, DOWNSPOUT AND SPLASHPAD
RAISE PARAPET AT STAIRWAY C
RAISEPARAPET ATSTAIRWAY B
RAISE PARAPET AT BH6
RAISE PARAPET AT BH 4 & 5 PRIORTO METAL CLADDING OVERLAY
TYP
TYP
INSTALL RAISED COUNTER FLASHING TO ALLOW 8” FROM FINISHED ROOF TO TOP OF COUNTER FLASHING
PROVIDE RAIL AT 42” MIN. ABOVE FINISHED ROOF. REFER TO SHEET A-518.
PROVIDE METAL LADDERS
RAISE PARAPET AT BH 6 PRIOR TO METAL CLADDING OVERLAY
RAISE PARAPET AT BH 4 & 5 PRIOR TO METAL CLADDING OVERLAY OR STUCCO INSTALLATION.
PROVIDE RAIL AT 42”MIN. ABOVE FINISHED
FLOOR. REFER TOSHEET A-518.
RAISED METAL SCUPPER,SPLASH PAD AND 2
SQUARE FEET MASONRY.
PROVIDE COUNTER FLASHING TO ALLOW 8” FROM FINISHED ROOF TO TOP OF COUNTER FLASHING. DO NOT RAISE
PROVIDE COUNTER FLASHING TO ALLOW 8” FROM FINISHED ROOF TO TOP OF COUNTER FLASHING. DO NOT RAISE
EAST ELEVATION SHEDScale: 1/8" = 1'-0"13
WEST ELEVATION STAIRWAY BScale: 1/8" = 1'-0"8
NORTH ELEVATION STAIRWAY D, BH3, BH4, BH5 & BH6Scale: 1/8" = 1'-0"20
NORTH ELEVATION STAIRWAY AScale: 1/8" = 1'-0"4
PROVIDE RAIL AT 42” MIN.ABOVE FINISHED FLOOR.REFER TO SHEET A-518.
NO METAL CLADDINGOVERLAY OR STUCCO.
PROVIDE RAIL AT 42” MIN. ABOVE FINISHED FLOOR. REFER TO SHEET A-518.
RAISE PARAPET AT STAIRWAY C. NO METAL CLADDING
RAISE PARAPET AT STAIRWAY B.NO METAL CLADDING
PROVIDE RAIL AT 42” MIN. ABOVE FINISHED FLOOR. REFER TO SHEET A-518.
MODIFY AND REINSTALL MTL CLADDING @ SHED.
PROVIDE RAIL AT 42” MIN. ABOVE FINISHED FLOOR. REFER TO SHEET A-518.
PROVIDE RAIL AT 42”MIN. ABOVE FINISHED
FLOOR. REFER TOSHEET A-518.
RAISE PARAPET AT BH 4 & 5. NO METAL CLADDING OR STUCCO.
RAISE PARAPET AT BH 6. NO METAL CLADDING OR STUCCO.
NO METALCLADDING
OVERLAYOR STUCCO
RAISE PARAPETPRIOR TO METAL
CLADDING OVERLAY
RAISE PARAPET PRIOR TO METAL CLADDING OVERLAY
RAISE PARAPETPRIOR TO METAL
CLADDINGOVERLAY
RAISE PARAPET PRIOR TO METAL CLADDING OVERLAY
PROVIDE RESIN ROOF SYSTEM PER ROOF PLANS
PROVIDEROOF SYSTEM
PER ROOFPLANS
PROVIDE METAL CLADDING AND EXPANSION JOINTS
EXISTING ELEVATOR BULKHEADDOOR TO REMAIN PROVIDE RESIN ROOF
SYSTEM PER ROOF PLANS
REFER TO ELECTRICAL AND MECHANICALDRAWINGS FOR ADDITIONAL INFORMATION.
TYP.
EXISTING BH3STAIRTOWER TO
REMAIN
EXISTING BH3 DOOR TO NOT BE REMOVED OR RAISED
METAL CLADDING OVERLAY
TYP
TYPTYP
TYP
TYP
TYP
RAISE PARAPET AT STAIR D. NO METAL CLADDING
0 5 10 15 20 25 FT
PROVIDE PARAPET WITH COUNTER FLASHING
BULKHEAD ROOF BEYOND
SEE SKYLIGHT DRAWINGS FOR ADDITIONAL NOTES
PROVIDE RAISED STRUCTURALWALL FOR SKYLIGHT ATTACHMENT
PER SKYLIGHT AND STRUCTURALDRAWINGS
SEE SKYLIGHT DRAWINGS FOR ADDITIONAL NOTES
RELOCATE EXISTING WALLVENTS TO ROOF PER
SKYLIGHT AND MECHNICALDRAWINGS
RELOCATE EXISTING WALL VENTS TO ROOF PER SKYLIGHT AND MECHNICAL DRAWINGS
SEE SKYLIGHT DRAWINGS FOR ADDITIONAL NOTES
TYP.
PROVIDE COUNTER FLASHING TO ALLOW 8” FROM FINISHED ROOF TO TOP OF COUNTER FLASHING. DO NOT RAISE
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
RAISE PARAPET. NOMETAL CLADDING
OVERLAY OR STUCCOPROVIDE RAIL AT 42”
MIN. ABOVE FINISHEDFLOOR. REFER TO
SHEET A-518.
EAST ELEVATION STAIRWAY CScale: 1/8" = 1'-0"12
INSTALL RAISED COUNTER FLASHING TO ALLOW 8” FROM FINISHED ROOF TO TOP OF COUNTER FLASHING
1
A-511
3
A-516
4
A-507
1/2
A-540
1
A-505
2
A-507
2
A-513SIM
4
A-507
2
A-515
1
A-513
1
A-519
1
A-510
3
A-515
1
A-514
1
A-504
2
A-503
3
A-510
3
A-508
3
A-509
4
A-509
1
A-509
3
A-507
1
A-503
1
A-505
1/2
A-540
4
A-508
1
A-511
4
A-507
1
A-515
2
A-513
1/2
A-516
2
A-503
2
A-511 SIM
1/2
A-540
1
A-541
1
A-511
2
A-513
1
A-515
1
A-511
1
A-506
3
A-507
5
A-515
1
A-511SIM
1
A-507
4
A-515 TYP
4
A-515
2
A-513
1
A-515
1
A-511
4
A-515 TYP
1
A-511
TYP
4
A-507
2
A-503
1/2
A-516
3
A-516
2
A-511
SIM
2
A-503
5
A-515
TYP
5
A-515
TYP
4
A-508
3
A-508
2
A-515
1
A-513
3
A-516
1/2
A-516
1
A-508
2
A-517
2
A-511
4
A-515
4
A-5083
A-507
1
A-517
1
A-509
3
A-510
1
A-509
2
A-509
3
A-510
D1
1/2
A-516
D2
1/2
A-516
3
A-516
D2
D2
D3
10
1
A-541
1
A-541
2
A-503
1
A-510
1
A-510
1/2
A-540
1
A-541
2
A-512
2
A-513
3
A-507
LIGHT FIXTURE AND CONDUIT.
SEAL FIVE (5) PENETRATIONS THROUGH CLADDING AT EXISTING MECH. PIPES AND DUCTS. REFER TO MECH. DRAWINGS.
CONDUIT.
LIGHT FIXTURES, CONDUIT AND JUNCTION BOXES.
LIGHT FIXTURES,CONDUIT AND
JUNCTION BOXES.
PROVIDE STUCCO OVER EXISTING AND RAISED MASONRY PARAPET. TYP.
PROVIDE STUCCO OVER EXISTING AND RAISED MASONRY PARAPET. TYP.
PROVIDE RAIL AT42” MIN. ABOVE
FINISHED FLOOR.REFER TO SHEET
A-518.
PROVIDE SCUPPER,DOWNSPOUT AND
SPLASHPAD.
PROVIDE RAILING. REFER TO DETAIL 2 ON SHEET A-504.
PROVIDE RAILING. REFER TO DETAIL 2 ON SHEET A-504.
PROVIDE RAILING. REFER TO DETAIL 2 ON SHEET A-504.
PROVIDE RAILING. REFER TO DETAIL2 ON SHEET A-504.
PROVIDE RAILING.
PROVIDE RAILING. REFER TO DETAIL 2 ON SHEET A-504.
PROVIDE RAILING.REFER TO DETAIL 2 ON
SHEET A-504.
PROVIDE STUCCO.
REPAIR STUCCO AT CHINMEY.
MODIFY AND REINSTALL MTL CLADDING @ SHED.
2
2
2
PROVIDE PRECAST COPING STONES WITH INTEGRAL DRIPS AT INBOARD AND OUTBOARD SET IN FULL MORTAR BED OVER SAWTOOTH FLASHING WITH RECEIVER AND EXTENSION AT INBOARD. SEAL ALL JOINTS.
PROVIDE METAL CLADDING OVER EXISTING STUCCO/MASONRY. UNLESS OTHERWISE NOTED. REPAIR DETERIORATED/FAILING MASONRY AND STUCCO PRIOR TO METAL CLADDING INSTALLATION.
PROVIDE DOOR SILL, BLOCKING AND ASSOCIATED FLASHING PER FINISHED ROOF HEIGHT. REFER TO DETAILS.
PROVIDE FACE MASONRY AND REPOINTING PRIOR TO METAL CLADDING OVERLAY, UNLESS OTHER WISE SPECIFIED
POINT CAST STONE JOINTS PRIOR TO METAL CLADDING OVERLAY
RAISED ROOF HEIGHT VARIES. R-30CI AVERAGE
PROVIDE LINTEL/SPANDREL AND ASSOCIATED FLASHING PER DOOR. ARCHITECT SHALL BE NOTIFIED OF HEIGHT LIMITATIONS. REFER TO DETAILS.
PROVIDE METAL COPINGS. REFER TO DETAILS. STUCCO DUTCHMAN PRIOR TO METAL CLADDING OVERLAY. REFER TO DETAILS.
PROVIDE BUILT-IN TWO PART STEPPED METAL COUNTER FLASHING. RAISE TO ACCOMMODATE PROVIDED ROOFING HEIGHT. RAISE LOW COPINGS WHERE INDICATED. REFER TO DETAILS.
PROVIDE GRAVEL STOPS WITH CONTINUOUS CLEAT AND TREATED WOOD BLOCKING
POINT MASONRY AND TERRA COTTA.PROVIDE COATING AT EXISTING STUCCO.
REPLACE FULL WIDTH OF PARAPET
PROVIDE CORNICE ABOVE REBUILT PARAPET PER CORNICE DETAILS. SEAL ALL JOINTS.
PROVIDE CONDUIT AND JUNCTION BOX BEHIND CLADDING. PROVIDE LIGHT FIXTURE THROUGH CLADDING AND SEAL PERIMETER. REFER TO ELEC. DRAWINGS.
EXPANSION JOINT.E.J.
LEGEND:
REVISED DRAWING - 4/17/2019