Updated 07/28/2015
Printed 07/26/2018 Page 1 of 5 Project No. 45558-C, H, P, E
DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON A. ROCKEFELLER
EMPIRE STATE PLAZA ALBANY, NY 12242
ADDENDUM NO. 2 TO PROJECT NO. 45558-C, H, P, E
CONSTRUCTION, HVAC, PLUMBING, AND ELECTRICAL WORK
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
CORTLANDT MANOR, NY 10567
July 26, 2018
NOTE: This Addendum forms a part of the Contract Documents. Insert it in the Project Manual.
Acknowledge receipt of this Addendum in the space provided on the Bid Form.
CONSTRUCTION WORK SPECIFICATIONS
1. Page 101423-2, Paragraph 2.01 C 2: Delete this Subparagraph in its entirety and replace with:
“2. Tactile Characters to comply with ADA and ANSI requirements.”
2. Page 101423-2, Paragraph 2.01 E: Add the following Subparagraph:
“5. Size: 6 inches wide by 6 inches high.”
3. SECTION 310000 EARTHWORK: Add the accompanying Section (pages 310000-1 thru
310000-9) to the Project Manual.
HVAC WORK SPECIFICATIONS
4. Page 089100-2, Paragraph 2.02 A: Delete this Paragraph in its entirety and replace with:
“A. Provide sheet metal blank off panel with 2-inch thick aluminum skin insulated sandwich
panel attached to louver with gasket and anchor to wall.”
5. Page 237313-1, Paragraph 1.01 A: Delete this Paragraph in its entirety and replace with:
“A. Wiring for Motors and Motor Controllers: Section 260523”
6. Page 237313-3, Paragraph 2.02 C 4d: Delete this Subparagraph in its entirety.
7. Page 238113-1, Paragraph 1.01 E: Delete this Subparagraph in its entirety.
![Page 2: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/2.jpg)
ADDENDUM NO. 2 TO PROJECT NO. 45558-C, H, P, E July 26, 2018
Updated 07/28/2015
Printed 07/26/2018 Page 2 of 5 Project No. 45558-C, H, P, E
PLUMBING WORK SPECIFICATIONS
8. Page 211313-4, Paragraph 2.02 A 1: Delete this Subparagraph in its entirety and replace with:
“1. Upright or Pendent Quick Response Type: Deflector designed to distribute water
downward in a uniform hemisphereical spray pattern.”
ELECTRICAL WORK SPECIFICATIONS
9. SECTION 260519 WIRING, GENERAL – 600 VOLTS AND UNDER (pages 260519-1 thru
260519-13) accompanies this Addendum and supersedes the same numbered originally issued
specification.
10. Page 256110-1, SECTION 265110: Delete this Section number in its entirety and replace with
the following:
“SECTION 265160”
11. Page 262726-2, PART 2 PRODUCTS: Add the following Paragraph:
“2.06 WAPs
A. WAP: Cisco Aironet 2800i Access Point. 802.11ac Wave 2 standard. Include a
Cisco 5 Seat License Pack. This is the basis of design; substitutions are not
permitted.”
12. Page 262726-3, Paragraph 3.01: Add the following Subparagraph:
“G. WAPs:
1. Install per the manufacturer’s instructions.
2. Coordinate with the Director’s Representative for testing and system
integration.”
13. Page 283105-1, Paragraph 1.01: Delete this Paragraph in its entirety.
14. Page 283105-6, Paragraph 2.04 B: Delete this Paragraph in its entirety.
CONSTRUCTION WORK DRAWINGS
15. Drawing No. G-004, CONSTRUCTION FACILITY NOTES, Note 8: Delete this note in its
entirety and replace with the following:
“8. STAGING AREA (APPROXIMATELY 60' x 90') PROVIDED WITH A TEMPORARY
FENCE ENCLOSURE WITH 6-INCH TYPE 2 SUBBASE OVER FILTER FABRIC.
RESTORE LAWN AFTER COMPLETION OF THE PROJECT. COORDINATE
FINAL SIZE AND LOCATION WITH DIRECTOR'S REPRESENTATIVE.”
16. Drawing No. H-101:
a. BASEMENT ABATEMENT PLAN KEYED NOTES, Note 3: Delete this Note in its
entirety and replace with the following:
“3. ACM HAS BEEN IDENTIFIED IN THIS AREA. CONTRACTOR SHALL
EXERCISE CAUTION WHEN WORKING AROUND ACM. ANY
INCIDENTAL DISTURBANCE SHALL BE IMMEDIATELY BROUGHT TO
![Page 3: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/3.jpg)
ADDENDUM NO. 2 TO PROJECT NO. 45558-C, H, P, E July 26, 2018
Updated 07/28/2015
Printed 07/26/2018 Page 3 of 5 Project No. 45558-C, H, P, E
THE ATTENTION OF THE DIRECTOR'S REPRESENTATIVE AND
ENVIRONMENTAL CONSULTANT, AND THE AREA SHALL BE
VACATED BY ALL WORKERS.”
b. BASEMENT FLOOR PLAN, EXIST STORAGE ROOM B-5: Delete Keyed Note 3
from this room.
c. BASEMENT FLOOR PLAN, EXIST LATRINE B-14: Add Keyed Note 3 in this room.
17. Drawing No. A-103, FURNITURE AND EQUIPMENT PLAN KEYED NOTES, Note 4: Delete
this note in its entirety and replace with the following:
“4. UTILITY SHELF WITH MOP/BROOM HOLDERS PROVIDED BY C-CONTRACT.”
18. Revised Drawings:
a. Drawing Nos. S-101, A-001, A-101, A-102, A-104, A-401, A-501, and A-601, noted
“REVISED DRAWING 07/24/18” accompany this Addendum and supersedes the same
numbered originally issued drawing.
HVAC WORK DRAWINGS
19. Drawing No. M-103, noted “REVISED DRAWING 07/23/2018” accompanies this Addendum
and supersedes the same numbered originally issued drawing.
PLUMBING WORK DRAWINGS
20. Drawing Nos. F-101 and F-200, noted “REVISED DRAWING 07/24/2018” accompanies this
Addendum and supersedes the same numbered originally issued drawing.
ELECTRICAL WORK DRAWINGS
21. Drawing No. E-102:
a. KEYNOTES, Note 3: Delete this Note in its entirety and replace with the following:
“3. A/V ENCLOSURE 16”WIDE X 24”HIGH X 12” DEEP WITH LOCKABLE
HINGED DOOR. COLOR OF ENCLSURE SHALL BE DETERMINED BY
THE DIRECTOR’S REPRESENTATIVE. COORDINATE EXACT
LOCATION WITH DIRECTOR’S REPRESENTATIVE.
a. PROVIDE 2” EMT FROM CABINET TO 1ST-FLOOR COMM
ROOM, ROOM 1-3.
b. PROVIDE 1” EMT FROM COMM ROOM, ROOM 1-3 TO ROOF AT
A LOCATION DETERMINED BY THE DIRECTOR’S
REPRESENTATIVE.
c. PROVIDE 1” EMT FROM CABINET TO THE NORTH END TV
LOCATION OF B-9 AND B-11, PROVIDE J-BOX FOR TV OUTLET
i. CONTINUE THE CONDUIT TO THE MIDDLE OF EACH
ROOM FOR A DATA OUTLET (WAP).
ii. THE TV OUTLETS SHALL BE 60” AFF.
iii. PROVIDE TV OUTLET & JACKS FOR CAT 6 & COAX IN
SAME JUNCTION BOXES.
![Page 4: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/4.jpg)
ADDENDUM NO. 2 TO PROJECT NO. 45558-C, H, P, E July 26, 2018
Updated 07/28/2015
Printed 07/26/2018 Page 4 of 5 Project No. 45558-C, H, P, E
d. J-BOXES AT OUTLET LOCATIONS SHALL BE SURFACE TYPE
METAL BOXES.
e. PROVIDE WAP PLACED IN CENTER OF DAY ROOM CEILING
B-11. PROVIDE CAT 6 IN 3/4” C TO IDF IN FIRST FLOOR COMM
ROOM 1-3. PROVIDE WAP PLACED IN CENTER OF GAME ROOM
B-9. PROVIDE CAT 6 IN 3/4” C TO MDF IN ROOF B-4. PROVIDE A
NETWORK CABLE FROM THE PATCH PANEL TO THE SWITCH
AND A CAT 6 PATCH PANEL. PROVIDE A 5 SEAT LICENSE
PACK AND CISCO ACCESS POINT MODEL 2800I WHICH WILL
WORK WITH A CISCO WIRELESS LAN CONTROLLER MODEL
5508.
f. PROVIDE A CAT 6 AND TV GRADE COAX CABLE RUN FROM
THE TV LOCATIONS TO THE A/V ENCLOSURE.
g. PROVIDE A CAT 6 AND TV GRADE COAX CABLE RUN FROM
THE A/V ENCLOSURE TO THE FIRST FLOOR COMM ROOM,
ROOM 1-3.
h. ALL CAT 6 AND COAX CABLES SHALL BE TERMINATED WITH
CONNECTOR ON BOTH ENDS OF EACH.
i. PROVIDE A DUPLEX RECEPTACLE IN THE A/V CABINET FROM
THE PROPOSED CONVENIENCE WIREMOLD CIRCUITS.”
b. KEYNOTES, Note 6: Delete this note in its entirety and replace with the following:
“6. PROVIDE SINGLE DATA OUTLET AT HEIGHT INDICATED.
COORDINATE WITH DIRECTOR’S REPRESENTATIVE ON THE TYPE OF
“DATA OUTLET MOUNTING DEVICE” FOR THE DIRECTOR’S
REPRESENTATIVE SUPPLIED IP PHONE. THE DATA CABLE FROM
THIS DATA OUTLET WILL BE ROUTED TO COMM ROOM 1-3. THE
DIRECTOR’S REPRESENTATIVE WILL ARRANGE FOR THE IP PHONE
SET TO BE INSTALLED AND PROGRAMMED.”
c. BASEMENT FLOOR PLAN, EXIST ELEC. ROOM B-3: Delete Keyed Note 3 in this
room.
d. BASEMENT FLOOR PLAN, EXIST BOILER ROOM B-6: Add Keyed Note 8 to
ERV-1 in this room.
e. BASEMENT FLOOR PLAN, MECH ROOM B-18: Add Keyed Note 8 to
MAU-1 and EF-1in this room.
f. BASEMENT FLOOR PLAN, East side of building: Add Keyed Note 8 to HP-1 and
HP-2 outside.
g. BASEMENT FLOOR PLAN, GAME ROOM B-9: Delete Keyed Note 3 in this room
and add Keyed Note 8 to FCU-1 in this room.
h. BASEMENT FLOOR PLAN, DAY ROOM B-11: Delete Keyed Note 3 in this room and
add Keyed Note 8 to FCU-2 in this room.
i. BASEMENT FLOOR PLAN, EXIST BOILER ROOM B-6: Delete Keyed Note 9 at
ERV-1 circuit and replace with “DP-LNDRY” circuit.
![Page 5: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/5.jpg)
ADDENDUM NO. 2 TO PROJECT NO. 45558-C, H, P, E July 26, 2018
Updated 07/28/2015
Printed 07/26/2018 Page 5 of 5 Project No. 45558-C, H, P, E
22. Drawing No. E-103:
a. KEYNOTES, Note 1: Delete this note in its entirety and replace with the following:
“1. INSTALL LUMINARIES FROM SURPLUS FROM REMOVALS.
COORDINATE LOCATION WITH DIRECTOR’S REPRESENTATIVE
AFTER MECHANICAL EQUIPMENT IS INSTALLED. PROVIDE UNIT
STRUT AS REQUIRED TO MOUNT LUMINARIES. LOCATE LUMINARIES
SO THEY DO NOT OBSTRUCT ROOM DOOR OR MECHANICAL
EQUIPMENT FOR MAINTENANCE.”
b. KEYNOTES, Note 5: Delete this note in its entirety and replace with the following:
“5. RE-CIRCUIT FOR SWITCHING AT THE 2 DOORS. SEE SHEET E-200
LIGHTING CONTROLS SCHEDULE FOR LIGHTING CONTROLS. SEE
SHEET E-200 LIGHTING CONTROLS SCHEDULE FOR REQUIRED
EQUIPMENT FOR EACH ROOM.”
23. Drawing No. E-104, NOTES, Note 1: Delete this note in its entirety and replace with the
following:
“1. PROPOSED & RELOCATED DEVICES & APPLIANCES WILL BE ADDED OR
MAINTAINED ON THE EXISTING IDC & NAC CIRCUITS UNLESS THE
CIRCUITS HAVE REACHED THEIR APPLIANCE, DEVICE, OR FUNCTIONAL
LIMITS. PROVIDE ADDITIONAL CIRCUITS IF REQUIRED TO MEET THE
REQUIREMENTS OF THE DRAWINGS. PROVIDE THE SLC CIRCUIT FOR THE
FIRE PROTECTION INITIATION DEVICES IN THE BOILER ROOM. PROVIDE A
COMPLETE SET OF SHOP DRAWINGS WHICH MEET THE REQUIREMENTS OF
NFPA 72 PRIOR TO ANY WORK OR MODIFICATION OF THE FIRE ALARM
SYSTEM. THESE WILL BE SEALED AND SIGNED BY A NYS LICENSED
ENGINEER AND INCLUDE THE SYSTEM AND CIRCUITS AFFECTED BY
ADDITIONS OR CHANGES AS WELL AS LOADING, AND VOLTAGE DROP
CALCULATIONS INCLUDING ANY PROVIDED CIRCUITS. ALL ADDITIONAL
REQUIRED EQUIPMENT (HEADEND, BATTERIES, CIRCUITS, DEVICES,
APPLIANCES), AND LABOR TO MEET THE REQUIREMENTS OF THE
DRAWINGS SHALL BE INCLUDED IN THIS CONTRACT. THE CONTRACTOR IS
ENCOURAGED TO SEEK EXISTING CONDITIONS INFORMATION FROM THE
FIRE ALARM MAINTENANCE CONTRACTOR OF RECORD, RED HAWK, 6
SKYLINE DRIVE, HAWTHORNE, NY 10532, 914-769-8900. THE FIRE ALARM
MAINTENANCE CONTRACTOR SHALL ALSO BE USED FOR APPROVAL OF FA
WORK, WORK ON THE FACU, FINAL CONNECTIONS OF DEVICES,
APPLIANCES, AND TESTING WHICH SHALL BE SUBMITTED TO THE
DIRECTOR’S REPRESENTATIVE FOR APPROVAL. AT NO TIME SHALL THE
ELECTRICAL CONTRACTOR JEOPARDIZE THE EXISTING MAINTENANCE
CONTRACT FOR THIS FIRE ALARM SYSTEM.”
END OF ADDENDUM
Erik T. Deyoe, P.E.
Director, Division of Design
Design & Construction
![Page 6: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/6.jpg)
Updated 12/15/2010
Printed 07/25/2018 310000 - 1 Project No. 45558-C
SECTION 310000
EARTHWORK
PART 1 GENERAL
1.01 RELATED WORK SPECIFIED ELSEWHERE
A. Construction Facilities & Temporary controls: Section 015000.
1.02 DEFINITIONS
A. The following terms shall have the meanings ascribed to them in this Article,
wherever they appear in this Section.
1. Earth Excavation: The removal of all surface material not classified as
rock (as defined below).
2. Rock: Limestone, sandstone, shale, granite, and similar material in solid
beds or masses in its original or stratified position which can be removed
only by blasting operations, drilling, wedging, or use of pneumatic tools,
and boulders with a volume greater than 1.0 cu yd. Concrete building
foundations and concrete slabs, not indicated, with a volume greater than
1.0 cu yd shall be classified as rock.
a. Limestone, sandstone, shale, granite, and similar material in a
broken or weathered condition which can be removed with an
excavator or backhoe equipped with a bucket with ripping teeth
or any other style bucket shall be classified as earth excavation.
b. Masonry building foundations, whether indicated or not, shall be
classified as earth excavation.
3. Subgrade Surface: Surface upon which subbase is placed.
4. Structures: Buildings, footings, foundations, retaining walls, slabs,
tanks, mechanical and electrical appurtenances, or other man-made
stationary features constructed above or below the ground surface.
5. Landscaped Areas: Areas not covered by structures, walks, roads,
paving, or parking.
6. Unauthorized Excavation: The removal of material below required
elevation indicated on the Drawings or beyond lateral dimensions
indicated or specified without specific written direction by the Director’s
Representative.
1.03 SUBMITTALS
A. Product Data:
1. Filter Fabric: Manufacturer’s catalog sheets, specifications, and
installation instructions.
![Page 7: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/7.jpg)
Updated 12/15/2010
Printed 07/25/2018 310000 - 2 Project No. 45558-C
B. Samples: Submit samples as follows. Take the samples in the presence of the
Director’s Representative, and submit to the Directors Representative the
laboratory test results for gradation, proctors and soundness tests, when required.
These tests shall be performed in accordance with ASTM standards, shall be
performed and signed by a certified soils laboratory, and shall be submitted as
part of the original submittal. At a minimum the samples taken shall be of the
following quantities:
1. Subbase Course Type 2: 50 - 60 lb. (Two Samples).
PART 2 PRODUCTS
2.01 MATERIALS
A. Subbase Course Type 2: Stockpiled, crushed ledge rock or approved blast
furnace slag. Comply with the gradation and material requirements specified
below:
Sieve Percent Passing
Sieve Size Size opening (mm)
2 inch 50.8 100
1/4 inch 6.35 25-60
No. 40 0.425 5-40
No. 200 0.075 0-10
1. Magnesium Sulfate Soundness Test: 20 percent maximum loss by
weight after four test cycles.
2. Plasticity Index: The plasticity index of the material passing the No. 40
mesh sieve shall not exceed 5.0.
3. Elongated Particles: Not more than 30 percent, by weight, of the
particles retained on a 1/2 inch sieve shall consist of flat or elongated
particles. A flat or elongated particle is defined as one which has its
greatest dimension more than three times its least dimension.
2.02 GEOTECHNICAL FABRICS
A. Filter Fabric (GeoTextile)
1. Separation/Stabilization beneath subbase: Amoco 4551, Bonded Fibers
Products PN080, Maccaferri Gabions MacTex MX275 & 340, Mirafi
160N & 180N or equivalent.
![Page 8: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/8.jpg)
Updated 12/15/2010
Printed 07/25/2018 310000 - 3 Project No. 45558-C
PART 3 EXECUTION
3.01 PLACING FILTER FABRIC
A. Place and overlap filter fabric over existing topsoil in accordance with the
manufacturer’s installation instructions, unless otherwise shown.
B. Cover tears and other damaged areas with additional filter fabric layer extending
3 feet beyond the damage.
C. Do not permit traffic or construction equipment directly on filter fabric.
3.02 PLACING SUBBASE
A. Open graded Stone: Place material to depth indicated on drawing G-002 over
filter fabric. Compaction Testing is not required.
B. Provide smooth uniform transition to adjacent areas.
3.03 PROTECTION
A. Protect areas outside of staging area from traffic and erosion, and keep them free
of trash and debris.
END OF SECTION
![Page 9: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/9.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 1 Project No. 45558-E
SECTION 260519
WIRING, GENERAL - 600 VOLTS AND UNDER
PART 1 GENERAL
1.01 SUBMITTALS
A. Product Data: Catalog sheets, specifications and installation instructions.
1.02 PRODUCT DELIVERY
A. Mark and tag insulated conductors and cables for delivery to the site. Include:
1. Contractor’s name.
2. Project title and number.
3. Date of manufacture (month & year).
4. Manufacturer’s name.
5. Data which explains the meaning of coded identification (UL assigned
electrical reference numbers, UL assigned combination of color marker
threads, etc.).
6. Environmental suitability information (listed or marked “sunlight
resistant” where exposed to direct rays of sun; wet locations listed/marked
for use in wet locations; other applications listed/marked suitable for the
applications).
PART 2 PRODUCTS
2.01 INSULATED CONDUCTORS AND CABLES
A. Date of Manufacture: No insulated conductor more than one year old when
delivered to the site will be acceptable.
B. Acceptable Companies: General Cable Corporation., Cerro Wire & Cable Co. Inc.,
Prysmian Cables & Systems, or Southwire Co.
C. Conductors: Annealed uncoated copper or annealed coated copper in
conformance with the applicable standards for the type of insulation to be applied
on the conductor. Conductor sizes No. 8 and larger shall be stranded.
D. Types:
1. Electric Light and Power Wiring:
a. General: Rated 600V, NFPA 70 Type THHN/THWN-2 or
XHHW-2.
b. THHN/THWN-2 Gasoline and Oil Resistant: Polyvinylchloride
insulation rated 600 V with nylon jacket conforming to UL
requirements for type THHN/THWN-2 insulation, with the
words “GASOLINE AND OIL RESISTANT II” marked thereon.
![Page 10: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/10.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 2 Project No. 45558-E
2. Class 1 Wiring:
a. No. 18 and No. 16 AWG: Insulated copper conductors suitable
for 600 volts, NFPA 70 types KF-2, KFF-2, PAFF, PF, PFF,
PGF, PGFF, PTFF, SF-2, SFF-2, TF, TFF, TFN, TFFN, ZF, or
ZFF.
b. Larger than No. 16 AWG: Insulated copper conductors suitable
for 600 volts, in compliance with NFPA 70 Article 310.
c. Conductor with other types and thickness of insulation may be
used if listed for Class 1 circuit use.
3. Class 2 Wiring:
a. Multiconductor Cables: NFPA 70 Article 725, Types CL2P,
CL2R, CL2.
b. Other types of cables may be used in accordance with NFPA 70
Table 725.154(G) “Cable Substitutions”, as approved.
4. Class 3 Wiring:
a. Single Conductors No. 18 and No. 16 AWG: Same as Class 1
No. 18 and No. 16 AWG conductors except that:
1) Conductors are also listed as CL3.
2) Voltage rating not marked on cable except where cable
has multiple listings and voltage marking is required for
one or more of the listings.
b. Multiconductor Cables: NFPA 70 Article 725, Types CL3P,
CL3R, CL3.
c. Other types of cables may be used in accordance with NFPA 70,
Table 725.154(G) “Cable Substitutions”, as approved.
2.02 CATEGORY 6 TWISTED PAIR CABLE
A. Description: Four-pair, balanced-twisted pair cable, certified to meet transmission
characteristics of Category 6 cable at frequencies up to 250MHz.
B. Manufacturers: Subject to compliance with requirements, provide products by one
of the following:
1. 3M.
2. Belden CDT Networking Division/NORDX.
3. General Cable; General Cable Corporation.
C. Standard: Comply with NEMA WC 66/ICEA S-116-732 and TIA-568-C.2 for
Category 6 cables.
D. Conductors: 100-ohm, 23 AWG solid copper.
E. Shielding/Screening: Shielded twisted pairs (FTP).
F. Cable Rating: Plenum.
G. Jacket: Blue thermoplastic.
2.03 CATV COAXIAL CABLE
A. Description: Coaxial cable with a 75-ohm characteristic impedance designed for
CATV transmission.
B. Manufacturers: Subject to compliance with requirements, available manufacturers
![Page 11: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/11.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 3 Project No. 45558-E
offering products that may be incorporated into the Work include, but are not
limited to the following:
1. Alpha Wire.
2. Belden CDT Networking Division/NORDX.
3. Draka USA.
C. NFPA and UL compliance, listed and labeled by an NRTL acceptable to
authorities having jurisdiction as complying with UL 1655 and with NFPA 70,
"Community Antenna Television and Radio Distribution Systems" Article. Types
are as follows:
1. RG-6/U: UL Type CATVP.
a. No. 18 AWG, solid, copper-covered steel conductor.
b. Plenum rated.
c. Gas-injected, foam-PE insulation.
d. Shielded with 100 percent aluminum tape and [40] [60] percent
aluminum braid.
e. Double shielded with 100 percent aluminum foil shield, 60
percent aluminum braided inner shield, and 40 percent aluminum
braided outer shield.
f. Jacketed with [black] [white] PVC or PE.
g. Suitable for indoor installations.
2.04 ELECTRICAL CIRCUIT PROTECTIVE SYSTEM
A. Minimum 1-Hour Fire Rating: A system listed in UL Building Materials
Directory, product category Electrical Circuit Protective Systems (FHIT).
2.05 CONNECTORS
A. General:
1. Connectors specified are part of a system. Furnish connectors and
components, and use specific tools and methods as recommended by
connector manufacturer to form complete connector system.
2. Connectors shall be UL 486 A listed, or UL 486 B listed for combination
dual rated copper/aluminum connectors (marked AL7CU for 75 degrees
C rated circuits and AL9CU for 90 degrees C rated circuits).
B. Splices:
1. Spring Type:
a. Rated 105° C, 600V; Buchanan/Ideal Industries Inc.’s B-Cap,
Electrical Products Div./3M’s Scotchlok Type Y, R, G, B, O/B+,
R/Y+, or B/G+, or Ideal Industries Inc.’s Wing Nuts or Wire Nuts.
b. Rated 150° C, 600V; Ideal Industries Inc.’s High Temperature
Wire-Nut Model 73B, 59B.
2. Indent Type with Insulating Jacket:
a. Rated 105° C, 600V; Buchanan/Ideal Industries Inc.’s Crimp
Connectors, Ideal Industries Inc.’s Crimp Connectors, Penn-Union
Corp.’s Penn-Crimps, or Thomas & Betts Corp.’s STA-KON.
![Page 12: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/12.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 4 Project No. 45558-E
3. Indent Type (Uninsulated): Anderson/Hubbell’s Versa-Crimp,
VERSAtile, Blackburn/T&B Corp.’s Color-Coded Compression
Connectors, Electrical Products Div./3M’s Scotchlok 10000, 11000
Series, Burndy’s Hydent, Penn-Union Corp.’s BCU, BBCU Series, or
Thomas & Betts Corp.’s Compression Connectors.
4. Connector Blocks: NIS Industires Inc.’s Polaris System, or Thomas &
Betts Corp.’s Blackburn AMT Series.
5. Resin Splice Kits: Electrical Products Div./3M’s Scotchcast Brand Kit
Nos. 82A Series, 82-B1 or 90-B1, or Scotchcast Brand Resin Pressure
Splicing Method.
6. Heat Shrinkable Splices: Electrical Products Div./3M’s ITCSN, Raychem
Corp.’s Thermofit Type WCS, or Thomas & Betts Corp.’s SHRINK-KON
Insulators.
7. Cold Shrink Splices: Electrical Products Div./3M’s 8420 Series.
C. Gutter Taps: Anderson/Hubbell’s GP/GT with GTC Series Covers,
Blackburn/T&B Corp.’s H-Tap Type CF with Type C Covers, Burndy’s Polytap
KPU-AC, H-Crimpit Type YH with CF-FR Series Covers, ILSCO’s GTA Series
with GTC Series Covers, Ideal Industries Inc.’s Power-Connect GP, GT Series
with GIC covers, NSI Industries Inc.’s Polaris System, OZ/Gedney Co.’s PMX or
PT with PMXC, PTC Covers, Penn-Union Corp.’s CDT Series, or Thomas &
Betts Corp.’s Color-Keyed H Tap CHT with HTC Covers.
D. Terminals: Nylon insulated pressure terminal connectors by Amp-
Tyco/Electronics, Electrical Products Div./3M, Burndy, Ideal Industries Inc.,
Panduit Corp., Penn-Union Corp., Thomas & Betts Corp., or Wiremold Co.
E. Lugs:
1. Single Cable (Compression Type Lugs): Copper, one or 2 hole style (to
suit conditions), long barrel; Anderson/Hubbell’s VERSAtile VHCL,
Blackburn/T&B Corp.’s Color-Coded CTL, LCN, Burndy’s Hylug YA,
Electrical Products Div./3M Scotchlok 31036 or 31145 Series, Ideal
Industries Inc.’s CCB or CCBL, NSI Industries Inc.’s L, LN Series, Penn-
Union Corp.’s BBLU Series, or Thomas & Betts Corp.’s 54930BE or
54850BE Series.
2. Single Cable (Mechanical Type Lugs): Copper, one or 2 hole style (to suit
conditions); Blackburn/T&B Corp.’s Color-Keyed Locktite Series,
Burndy’s Qiklug Series, NSI Industries Inc.’s Type TL, Penn-Union
Corp.’s VI-TITE Terminal Lug Series, or Thomas & Betts Corp.’s
Locktite Series.
3. Multiple Cable (Mechanical Type Lugs): Copper, configuration to suit
conditions; Burndy’s Qiklug Series, NSI Industries Inc.’s Type TL, Penn-
Union Corp.’s VI-TITE Terminal Lug Series, or Thomas & Betts Corp.’s
Color-Keyed Locktite Series.
![Page 13: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/13.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 5 Project No. 45558-E
2.06 TAPES
A. Insulation Tapes:
1. Plastic Tape: Electrical Products Div./3M’s Scotch Super 33+ or Scotch
88, Plymouth Rubber Co.’s Plymouth/ Bishop Premium 85CW.
2. Rubber Tape: Electrical Products Div./3M’s Scotch 130C, or Plymouth
Rubber Co.’s Plymouth/Bishop W963 Plysafe.
B. Moisture Sealing Tape: Electrical Products Div./3M’s Scotch 2200 or 2210, or
Plymouth Rubber Co.’s Plymouth/Bishop 4000 Plyseal-V.
C. Electrical Filler Tape: Electrical Products Div./3M’s Scotchfil, or Plymouth
Rubber Co.’s Plymouth/Bishop 125 Electrical Filler Tape.
D. Color Coding Tape: Electrical Products Div./3M’s Scotch 35, or Plymouth
Rubber Co.’s Plymouth/Bishop Premium 37 Color Coding.
2.07 WIRE-PULLING COMPOUNDS
A. To suit type of insulation; American Polywater Corp.’s Polywater Series,
Electric Products Div./3M’s WL, WLX, or WLW, Greenlee Textron Inc.’s,
Cable Cream, Cable Gel, Winter Gel, Ideal Industries Inc.’s Yellow 77, Aqua-
Gel II, Agua-Gel CW, or Thomas & Betts Corp.’s Series 15-230 Cable Pulling
Lubricants, or Series 15-631 Wire Slick.
2.08 TAGS
A. Precision engrave letters and numbers with uniform margins, character size
minimum 3/16 inches high.
1. Phenolic: Two color laminated engraver’s stock, 1/16 inch minimum
thickness, machine engraved to expose inner core color (white).
2. Aluminum: Standard aluminum alloy plate stock, minimum .032 inches
thick, engraved areas enamel filled or background enameled with natural
aluminum engraved characters.
2.09 WIRE MANAGEMENT PRODUCTS
A. Cable Clamps and Clips, Cable Ties, Spiral Wraps, etc: Catamount/T&B Corp., or
Ideal Industries Inc.
2.10 TWISTED PAIR CABLE HARDWARE
A. Description: Hardware designed to connect, splice, and terminate twisted pair
copper communications cable.
B. Manufacturers: Subject to compliance with requirements, available manufacturers
offering products that may be incorporated into the Work include, but are not
limited to the following:
1. 3M.
![Page 14: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/14.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 6 Project No. 45558-E
2. Belden CDT Networking Division/NORDX.
3. General Cable; General Cable Corporation.
C. General Requirements for Twisted Pair Cable Hardware:
1. Comply with the performance requirements of Category 6.
2. Comply with TIA-568-C.2, IDC type, with modules designed for punch-
down caps or tools.
3. Cables shall be terminated with connecting hardware of same category or
higher.
D. Source Limitations: Obtain twisted pair cable hardware from same manufacturer
as twisted pair cable, from single source.
E. Connecting Blocks:
1. 110-style IDC for Category 6.
5. Provide blocks for the number of cables terminated on the block, plus 25
percent spare, integral with connector bodies, including plugs and jacks
where indicated.
F. Cross-Connect: Modular array of connecting blocks arranged to terminate building
cables and permit interconnection between cables.
1. Number of Terminals per Field: One for each conductor in assigned
cables.
G. Patch Panel: Modular panels housing numbered jack units with IDC-type
connectors at each jack location for permanent termination of pair groups of
installed cables.
1. Features:
a. Universal T568A and T568B wiring labels.
b. Labeling areas adjacent to conductors.
c. Replaceable connectors.
d. 24 or 48 ports.
2. Construction: 16-gauge steel and mountable on 19-inch (483 mm)
equipment racks.
3. Number of Jacks per Field: One for each four-pair.
H. Patch Cords: Factory-made, four-pair cables in 48-inch (1200-mm) lengths;
terminated with an eight-position modular plug at each end.
1. Patch cords shall have bend-relief-compliant boots and color-coded icons
to ensure performance. Patch cords shall have latch guards to protect
against snagging.
2. Patch cords shall have color-coded boots for circuit identification.
I. Plugs and Plug Assemblies:
1. Male; eight position; color-coded modular telecommunications connector
designed for termination of a single four-pair, 100-ohm, unshielded or
shielded twisted pair cable.
2. Standard: Comply with TIA-568-C.2.
3. Marked to indicate transmission performance.
J. Jacks and Jack Assemblies:
1. Female; eight position; modular; fixed telecommunications connector
designed for termination of a single four-pair, 100-ohm, unshielded or
shielded twisted pair cable.
2. Designed to snap-in to a patch panel or faceplate.
3. Standard: Comply with TIA-568-C.2.
![Page 15: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/15.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 7 Project No. 45558-E
4. Marked to indicate transmission performance.
K. Faceplate:
1. Two port, vertical single gang faceplates designed to mount to single gang
wall boxes.
2. Plastic Faceplate: High-impact plastic. Coordinate color with Section
262726 "Wiring Devices."
4. Metal Faceplate: Stainless steel, complying with requirements in Section
262726 "Wiring Devices."
5. For use with snap-in jacks accommodating any combination of twisted
pair, optical fiber, and coaxial work area cords.
a. Flush mounting jacks, positioning the cord at a 45-degree angle.
2.11 TWISTED PAIR GROUNDING
A. Comply with TIA-607-B.
2.12 TWISTED PAIR SOURCE QUALITY CONTROL
A. Testing Agency: Engage a qualified testing agency to evaluate cables.
C. Cable will be considered defective if it does not pass tests and inspections.
D. Prepare test and inspection reports.
2.13 COAXIAL CABLE HARDWARE
A. Description: Hardware designed to connect, splice, and terminate coaxial cable
with a 75-ohm characteristic impedance.
C. Coaxial-Cable Connectors: Type BNC, 75 ohms.
D. Jacks and Jack Assemblies: Modular, color-coded, with female Type BNC
connectors.
E. Patch Cords: Factory-made cables in 48-inch (1200-mm) lengths; terminated with
a male Type BNC connector at each end.
F. Faceplates:
1. Plastic Faceplate: High-impact plastic. Coordinate color with Section
262726 "Wiring Devices."
2. Metal Faceplate: Stainless steel, complying with requirements in Section
262726 "Wiring Devices."
3. For use with snap-in jacks accommodating any combination of twisted
pair, optical-fiber, and coaxial work area cords.
a. Machine printed, in the field, using clear adhesive-tape label.
2.14 COAXIAL CABLE GROUNDING
A. Comply with TIA-607-B.
2.15 COAXIAL CABLE SOURCE QUALITY CONTROL
A. Testing Agency: Engage a qualified testing agency to evaluate cables.
B. Cable will be considered defective if it does not pass tests and inspections.
C. Prepare test and inspection reports.
![Page 16: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/16.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 8 Project No. 45558-E
PART 3 EXECUTION
3.01 INSTALLATION
A. Install conductors in raceways after the raceway system is completed. Exceptions:
Type MC, MI, or other type specifically indicated on the drawings not to be
installed in raceways.
B. No grease, oil, or lubricant other than wire-pulling compounds specified may be
used to facilitate the installation of conductors.
3.02 CIRCUITING
A. Do not change, group or combine circuits other than as indicated on the drawings.
B. Do not change, group or combine circuits other than as indicated on the drawings
except as permitted under Section 260532 when reusing existing raceways.
3.03 COMMON NEUTRAL CONDUCTOR
A. A common neutral may not be used for any circuits.
3.04 CONDUCTOR SIZE
A. Conductor Size:
1. For Electric Light and Power Branch Circuits: Install conductors of size
shown on drawings. Where size is not indicated, the minimum size
allowed is No. 12 AWG.
2. For Class 1 Circuits:
a. No. 18 and No. 16 AWG may be used provided they supply loads
that do not exceed 6 amps (No. 18 AWG), or 8 amps (No. 16
AWG).
b. Larger than No. 16 AWG: Use to supply loads not greater than
the ampacities given in NFPA 70 Section 310.15.
3. For Class 2 Circuits: Any size to suit application.
4. For Class 3 Circuits: Minimum No. 18 AWG.
3.05 COLOR CODING
A. Color Coding for 120/208 Volt Electric Light and Power Wiring:
1. Color Code:
a. 2 wire circuit - black, white.
b. 3 wire circuit - black, red, white.
c. 4 wire circuit - black, red, blue, white.
2. White to be used only for an insulated grounded conductor (neutral). If
neutral is not required use black and red, or black, red and blue for phase
to phase circuits.
a. “White” for Sizes No. 6 AWG or Smaller:
![Page 17: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/17.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 9 Project No. 45558-E
1) Continuous white outer finish, or:
2) Three continuous white stripes on other than green
insulation along its continuous length.
3) Distinctive white markings (color coding tape) encircling
the conductor, installed on the conductor at time of its
installation. Install white color coding tape at
terminations, and at 1’ 0” intervals in gutters, pullboxes,
and manholes.
3. Colors (Black, Red, Blue):
a. For Branch Circuits: Continuous color outer finish.
b. For Feeders:
1) Continuous color outer finish, or:
2) Color coding tapes encircling the conductors, installed on
the conductors at time of their installation. Install color
coding tapes at terminations, and at 1’ 0” intervals in
gutter, pullboxes, and manholes.
B. Existing Color Coding Scheme: Where an existing color coding scheme is in use,
match the existing color coding if it is in accordance with the requirements of
NFPA 70.
C. Color Code For Wiring Other Than Electric Light and Power: In accordance with
ICEA standard S-73-532 (NEMA WC57-2004). Other coding methods may be
used, as approved.
3.06 INSTALLATION OF TWISTED-PAIR HORIZONTAL CABLES
A. Comply with NECA 1 and NECA/BICSI 568.
B. General Requirements for Cabling:
1. Comply with TIA-568-C.0, TIA-568-C.1, and TIA-568-C.2.
2. Comply with BICSI's "Information Transport Systems Installation
Methods Manual (ITSIMM), Ch. 5, "Copper Structured Cabling Systems,"
"Cable Termination Practices" Section.
3. Install 110-style IDC termination hardware unless otherwise indicated or
instructed.
4. Do not untwist twisted pair cables more than 1/2 inch (12 mm) from the
point of termination to maintain cable geometry.
5. Terminate all conductors; no cable shall contain unterminated elements.
Make terminations only at indicated outlets, terminals, cross-connects, and
patch panels.
6. MUTOA shall not be used as a cross-connect point.
7. Consolidation points may be used only for making a direct connection to
equipment outlets:
a. Do not use consolidation point as a cross-connect point, as a patch
connection, or for direct connection to workstation equipment.
b. Locate consolidation points for twisted-pair cables at least 49 feet
(15 m) from communications equipment room.
8. Cables may not be spliced. Secure and support cables at intervals not
exceeding 30 inches (760 mm) and not more than 6 inches (150 mm) from
![Page 18: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/18.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 10 Project No. 45558-E
cabinets, boxes, fittings, outlets, racks, frames, and terminals.
9. Install lacing bars to restrain cables, prevent straining connections, and
prevent bending cables to smaller radii than minimums recommended by
manufacturer.
10. Bundle, lace, and train conductors to terminal points without exceeding
manufacturer's limitations on bending radii, but not less than radii
specified in BICSI Information Transport Systems Installation Methods
Manual , Ch. 5, "Copper Structured Cabling Systems," "Cable
Termination Practices" Section. Use lacing bars and distribution spools.
11. Do not install bruised, kinked, scored, deformed, or abraded cable. Do not
splice cable between termination, tap, or junction points. Remove and
discard cable if damaged during installation, and replace it with new
cable.
12. Cold-Weather Installation: Bring cable to room temperature before
dereeling. Heat lamps shall not be used for heating.
13. In the communications equipment room, install a 10-foot- (3-m-) long
service loop on each end of cable.
14. Pulling Cable: Comply with BICSI Information Transport Systems
Installation Methods Manual, Ch. 5, "Copper Structured Cabling
Systems," "Pulling and Installing Cable" Section. Monitor cable pull
tensions.
3.4 INSTALLATION OF COAXIAL HORIZONTAL CABLES
A. Comply with NECA 1 and NECA/BICSI 568.
B. General Requirements for Cabling:
1. Comply with BICSI ITSIMM, Ch. 5, "Copper Structured Cabling
Systems," "Cable Termination Practices" Section.
2. Terminate all conductors; no cable shall contain unterminated elements.
Make terminations only at indicated outlets, terminals, and patch panels.
3. Cables may not be spliced. Secure and support cables at intervals not
exceeding 30 inches (760 mm) and not more than 6 inches (150 mm) from
cabinets, boxes, fittings, outlets, racks, frames, and terminals.
4. Install lacing bars to restrain cables, to prevent straining connections, and
to prevent bending cables to smaller radii than minimums recommended
by manufacturer.
5. Bundle, lace, and train conductors to terminal points without exceeding
manufacturer's limitations on bending radii, but not less than radii
specified in BICSI ITSIMM, Ch. 5, "Copper Structured Cabling Systems,"
"Cable Termination Practices" Section. Use lacing bars and distribution
spools.
6. Do not install bruised, kinked, scored, deformed, or abraded cable. Do not
splice cable between termination, tap, or junction points. Remove and
discard cable if damaged during installation and replace it with new cable.
7. Cold-Weather Installation: Bring cable to room temperature before
dereeling. Heat lamps shall not be used for heating.
8. In the communications equipment room, install a 10-foot- (3-m-) long
service loop on each end of cable.
9. Pulling Cable: Comply with BICSI ITSIMM, Ch. 5, "Copper Structured
![Page 19: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/19.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 11 Project No. 45558-E
Cabling Systems," "Pulling Cable" Section. Monitor cable pull tensions.
3.05 SEPARATION FROM EMI SOURCES
A. Comply with recommendations from BICSI's "Telecommunications Distribution
Methods Manual" and TIA-569-D for separating unshielded copper
communication cable from potential EMI sources, including electrical power lines
and equipment.
B. Separation between open communications cables or cables in nonmetallic
raceways and unshielded power conductors and electrical equipment shall be as
follows:
1. Electrical Equipment Rating Less Than 2 kVA: A minimum of 5 inches
(127 mm).
2. Electrical Equipment Rating between 2 and 5 kVA: A minimum of 12
inches (300 mm).
3. Electrical Equipment Rating More Than 5 kVA: A minimum of 24 inches
(600 mm).
C. Separation between communications cables in grounded metallic raceways and
unshielded power lines or electrical equipment shall be as follows:
1. Electrical Equipment Rating Less Than 2 kVA: A minimum of 2-1/2
inches (64 mm).
2. Electrical Equipment Rating between 2 and 5 kVA: A minimum of 6
inches (150 mm).
3. Electrical Equipment Rating More Than 5 kVA: A minimum of 12 inches
(300 mm).
D. Separation between communications cables in grounded metallic raceways, power
lines, and electrical equipment located in grounded metallic conduits or enclosures
shall be as follows:
1. Electrical Equipment Rating Less Than 2 kVA: No requirement.
2. Electrical Equipment Rating between 2 and 5 kVA: A minimum of 3
inches (76 mm).
3. Electrical Equipment Rating More Than 5 kVA: A minimum of 6 inches
(150 mm).
E. Separation between Communications Cables and Electrical Motors and
Transformers, 5 kVA or HP and Larger: A minimum of 48 inches (1200
mm).
F. Separation between Communications Cables and Fluorescent Fixtures: A
minimum of 5 inches (127 mm).
3.06 IDENTIFICATION
A. Identification Tags: Use tags to identify feeders and designated circuits. Install
tags so that they are easily read without moving adjacent feeders or requiring
removal of arc proofing tapes. Attach tags with non-ferrous wire or brass chain.
1. Interior Feeders: Identify each feeder in pullboxes and gutters. Identify
by feeder number and size.
![Page 20: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/20.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 12 Project No. 45558-E
3.07 WIRE MANAGEMENT
A. Use wire management products to bundle, route, and support wiring in junction
boxes, pullboxes, wireways, gutters, channels, and other locations where wiring is
accessible.
3.08 EQUIPMENT GROUNDING CONDUCTOR
A. Install equipment grounding conductor:
1. Where specified in other Sections or indicated on the drawings.
2. In conjunction with circuits recommended by equipment manufacturers to
have equipment grounding conductor.
B. Equipment grounding conductor is not intended as a current carrying conductor
under normal operating circumstances.
C. Color Coding For Equipment Grounding Conductor:
1. Color Code: Green.
2. “Green” For sizes No. 6 AWG or Smaller:
a. Continuous green outer finish, or:
b. Continuous green outer finish with one or more yellow stripes, or:
c. Bare copper (see exception below).
3. “Green” For Sizes Larger Than No. 6:
a. Stripping the insulation or covering from the entire exposed
length (see exception below).
b. Marking the exposed insulation or covering with green color
coding tapes.
c. Identify at each end and at every point where the equipment
grounding conductor is accessible.
3.09 INSULATED CONDUCTOR AND CABLE SCHEDULE - TYPES AND USE
A. Electric Light and Power Circuits:
1. Type THHN/THWN-2 or XHHW-2. : Wiring in dry or damp locations
(except where special type insulation is required).
2. THHN/THWN-2: Wiring installed in existing raceway systems (except
where special type insulation is required).
3. THHN/THWN-2 or XHHW-2: Wiring for electric discharge lighting
circuits (fluorescent, HID), except where fixture listing requires wiring
rated higher than 90° C.
3.10 CONNECTOR SCHEDULE - TYPES AND USE
A. Temperature Rating: Use connectors that have a temperature rating, equal to, or
greater than the temperature rating of the conductors to which they are connected.
B. Splices:
1. Dry Locations:
![Page 21: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/21.jpg)
Updated 06/03/2014
Printed 07/19/2018 260519 - 13 Project No. 45558-E
a. For Conductors No. 8 AWG or Smaller: Use spring type pressure
connectors, indent type pressure connectors with insulating
jackets, or connector blocks (except where special type splices are
required).
b. For Conductors No. 6 AWG or Larger: Use connector blocks or
uninsulated indent type pressure connectors. Fill indentions in
uninsulated connectors with electrical filler tape and apply
insulation tape to insulation equivalent of the conductor, or
insulate with heat shrinkable splices or cold shrink splices.
c. Gutter Taps in Panelboards: For uninsulated type gutter taps fill
indentions with electrical filler tape and apply insulation tape to
insulation equivalent of the conductor, or insulate with gutter tap
cover.
C. Terminations:
1. For Conductors No. 10 AWG or Smaller: Use terminals for:
a. Connecting wiring to equipment designed for use with terminals.
2. For Conductors No. 8 AWG or Larger: Use compression or mechanical
type lugs for:
a. Connecting cables to flat bus bars.
b. Connecting cables to equipment designed for use with lugs.
3. For Conductor Sizes Larger Than Terminal Capacity On Equipment:
Reduce the larger conductor to the maximum conductor size that terminal
can accommodate (reduced section not longer than one foot). Use
compression or mechanical type connectors suitable for reducing
connection.
END OF SECTION
![Page 22: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/22.jpg)
1. PROVIDE INTUMESCENT PAINT ON EXPOSED STEEL UNLESS NOTED OTHERWISE.
2. INSTALL CHANNELS FOR NEW OPENINGS IN EXISTING CONCRETE WALL PRIOR TO CUTTING OF WALL OPENING.
3. REFER TO A-101 FOR REMOVAL EXTENTS & LOCATIONS.
4. EXPOSED STEEL SHALL BE AESS CATEGORY 2 UNLESS NOTED OTHERWISE.
5. COORDINATE WITH PLUMBING CONTRACTOR FOR FLOOR DRAINS, FLOOR CLEANOUTS, AND LINT INTERCEPTOR BEING PROVIDED UNDER THE PLUMBING CONTRACT PRIOR TO REMOVAL AND INFILL OF EXISTING CONCRETE SLAB.
6. TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, THESE PLANS ARE IN CONFORMANCE WITH THE 2016 SUPPLEMENT OF THE NEW YORKSTATE ENERGY CONSERVATION CONSTRUCTION CODE.
BASEMENT FLOOR PLAN GENERAL NOTES:
2 1
/4"
5 1
/2"
3 1
/2"
8' - 2"
3/4"Ø SLIP-CRITICAL THROUGH BOLT @ 12" OC, STAGGER LAYERS BY 6" OFFSET(NOTE 1 & 2)
NOTES:1. FIRST BOLT LINE IS NOT STAGGERED AND IS TO START 1 1/2" FROM CHANNEL END.2. WHEN USED IN CONJUNCTION W/ 3/S-101 ALIGN BOLT HOLES @ ANGLES3. INSTALL CHANNELS FIRST BEFORE REMOVING EXISTING WALL4. EXISTING WALL REINFORCEMENT NOT SHOWN FOR CLARITIY. 5. AT EXISTING DUCT OPENING PROVIDE GROUT HOLE IN CHANNEL; FILL VOID WITH
NON-SHRINK GROUT AFTER CHANNEL IS INSTALLED.
EXISTING CONC. WALL
EXISTING CONC. SLAB
EXISTING CONC. ENCASED STEEL BEAM BEYOND
1/4" CLOSURE PLATE, TYP
2-12
GRIND SMOOTH,TYP
TOP OF OPENING
9' - 2" +/-BOTTOM OF BEAM
REMOVE PORTION OF EXISTING WALL (REFER TO SHEET A-101).
C10x15.3
L4x4x3/8x0'-8"
3/4"Ø SLIP-CRITICAL THROUGH BOLTS, TYP
3 1
/2"
5 1
/2"
2 1
/4"
6"2 1/2"
EXISTING CONC. WALL
EXIST CONC. SLAB
8' - 2"
(2) 5/8"Ø HILTI-HY 200 HIS-N B7; EMBED 6 3/4", TYP
TYP
1' - 0"
NOTE: CLOSURE PLATE NOT SHOWN FOR CLARITY
TOP OF OPENING
C10x15.3
VIF5"
#4x1'-4"@18"OC, DRILL AND GROUT INTO EXIST SLAB W/ AN ADHESIVE SYSTEM, EMBED 4 1/4"
#4@18"OC EA WAYROUGHEN EXIST CONC SURFACE AND APPLY BONDING AGENT
PROVIDE VAPOR RETARDER LAPPED 3" MIN OVER EXISTING VAPOR RETARDER
6" COMPACTED SUBBASE
8"
MIN
D4"
MIN
3D MIN
11
P C
ON
TR
AC
T
EXISTING VAPOR RETARDER TO REMAIN
911 6 3 1
A
B
C
2
S-101 3
S-101
1' - 0"1' - 0" 1' - 0" 0' - 10" 1' - 0"
2
S-101
8
S-1013
S-101
2
S-101
EXISTING CMU WALL, TYP
EXISTING CONCRETE WALL, TYP
EXISTING SLAB ON GROUND
UNEXCAVATED
C10x15.3C10x15.3C10x15.3
C10x15.3
APPROXIMATE EXTENT OF INFILL SLAB ON GROUND (340 SF). COORDINATE EXACT EXTENTS WITH PLUMBING CONTRACTOR
1' - 0"
5' - 0" +/-
0' - 11" 0' - 11"
5' - 0" +/-
1' - 0"
1' - 0"0' - 7"
3
S-101
3
S-101
EXTENT OF SCHEDULED CORRIDOR WALL SHOWN FOR REFERENCE
MIN1' - 0"
MIN1' - 0"
MIN
1' -
0"
SIM SIM
MIRR
5' - 6" +/-
3' - 1"
5' - 6" +/-EXISTING DUCT OPENING
6
S-101
EXISTING 12I10.99 ALUM. BEAM (ALLOY 6061-T6)
10I10.286 ALUM. BEAM
(ALLOY 6061-T6)
6I4.030 ALUM. BEAM (ALLOY 6061-T6)
NOTES:1.TOP OF STEEL ELEVATION IS -0' - 2 1/4", REFERENCED FROM 1ST FLOOR TOP OF SLAB UNLESS NOTED OTHERWISE.2. INDICATES SPAN DIRECTION OF EXISTING ALUMNINUM GRATING.3.CUT EXISTING GRATING AND PROVIDE OPENINGS FOR MECHANICAL AND PLUMBING PENETRATIONS. COORDINATE
SIZE AND LOCATION WITH MECHANICAL AND PLUMBING CONTRACTORS.
7
S-101
M
M
EXISTING FOUNDATION WALL, TYP
TYPP
6I4.030 ALUM. BEAM (ALLOY 6061-T6)
6I4.030 ALUM. BEAM (ALLOY 6061-T6)
TYP
15' -
0"
11' - 0"
7' -
0"
+/-
2' - 2" +/- 2' - 2" +/-
MECHANICAL PENETRATION
MECHANICAL PENETRATION
PLUMBINGPENETRATION
C
PL 1/4"x3-1/2"x0'-6" W/ (2) 3/4"ØA325 BOLTS (NOTE 1&2)
NOTES:1. PLATES & ANGLES SHALL BE 6061-T6 ALUMINUM.2. BOLTS SHALL BE GALVANIZED; ISOLATING SLEEVES & WASHERS SHALL BE USED.
2L3-1/2"x3-1/2"x1/4"x0'-6" W/ (2) 3/4"Ø A325 BOLTS (NOTE 1&2)
(4) 5/8"Ø SS HILTI-KWIK BOLT TZ; EMBED 4" @ 5" GAUGE
EXISTING ALUMINUM GRATING SUPPORT
T/GRATINGEXISTING
3/16
3/16
1 1
/2"
1 1
/2"
3"
1 1
/2"
2"1 1/2"
4"
4 3
/4"
1 1
/2"
1 1
/2"
3"
1 1
/2"
1 1/2"2"
EXISTING ALUMINUM GRATING
PL 1/4"x3-1/2"x0'-3-1/2" W/ (2) 1/2"ØA325 BOLTS (NOTE 1&2)
NOTES:1. PLATES & ANGLES SHALL BE 6061-T6 ALUMINUM.2. BOLTS SHALL BE GALVANIZED; ISOLATING SLEEVES & WASHERS SHALL BE USED.
2L3-1/2"x3-1/2"x1/4"x0'-6" W/ (2) 1/2"Ø A325 BOLTS (NOTE 1&2)
(4) 5/8"Ø SS HILTI-KWIK BOLT TZ; EMBED 4" @ 5" GAUGE
1 1
/4"
3/4
"2
"3
/4"
1 1/2"2"
1 1
/4"
3/4
"2
"3
1/4
"
1 1/2"2"
4 1
/2"
4"
3/16
3/16
T/GRATINGEXISTING
EXISTING ALUMINUM GRATING
3/4"Ø SLIP-CRITICAL THROUGH BOLT @ 12" OC, STAGGER LAYERS BY 6" OFFSET(NOTE 1 & 2)
EXISTING CONC. WALL
EXISTING CONC. SLAB
EXISTING CONC. ENCASED STEEL BEAM BEYOND
1/4" CLOSURE PLATE, TYP
2-12
GRIND SMOOTH,TYP
9' - 2" +/-BOTTOM OF BEAM
REMOVE PORTION OF EXISTING WALL (REFER TO SHEET A-101).
C10x15.3
7' - 2" +/-TOP OF OPENING
NOTES:1. FIRST BOLT LINE IS NOT STAGGERED AND IS TO START 1 1/2" FROM CHANNEL END.2. WHEN USED IN CONJUNCTION W/ 3/S-101 ALIGN BOLT HOLES @ ANGLES3. INSTALL CHANNELS FIRST BEFORE REMOVING EXISTING WALL4. EXISTING WALL REINFORCEMENT NOT SHOWN FOR CLARITIY.
3 1
/2"
5 1
/2"
2 1
/4"
SHEET TITLE:
APPROVED:
FIELD CHECK:
DRAWN BY:
DESIGNED BY:
PROJECT
NUMBER:
SHEET OF
DRAWING NUMBER:
MARK DATE DESCRIPTION
CONTRACT:
TITLE:
LOCATION:
CLIENT:
CONSULTANT
WARNING:
THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS
DONE UNDER THE DIRECTION OF A COMPARABLE
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
ENGINEER FOR AN ENGINEER, OR LANDSCAPE ARCHITECT
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THE NEW
YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS
A CLASS "A" MISDEMEANOR.
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
11 BEAR MOUNTAIN BRIDGE ROAD
CORTLANDT MANOR, NY
DIVISION OF MILITARY
AND NAVAL AFFAIRS
CONSTRUCTION
45558455584555845558----CCCC
06/19/2018 BID DOCUMENTS
7/2
4/2
018 3
:56:2
2 P
M
S-101S-101S-101S-101
SSSSTTTTRRRRUUUUCCCCTTTTUUUURRRRAAAALLLL PPPPLLLLAAAANNNN AAAANNNNDDDD
DETAILSDETAILSDETAILSDETAILS
C MESSIER
C MESSIER
M TRACEY
-
N
SCALE : 3/4" = 1’−0"2
WALL REINFORCEMENT AT OPENING DETAILSCALE : 3/4" = 1’−0"
3
WALL REINFORCEMENT CONNECTION ATINTERSECTING WALL DETAIL
SCALE : 3/4" = 1’−0"4
INFILL SLAB ON GROUND DETAIL
1 1
SCALE : 1/8" = 1’−0"1
BASEMENT FLOOR PLAN
SCALE : 1/4" = 1’−0"5
PARTIAL PLAN AT EXISTING AREAWAY
SCALE : 3/4" = 1’−0"6
SECTIONSCALE : 3/4" = 1’−0"
7SECTION
07/24/2018 ADDENDUM 22
REVISED DRAWING 07/24/2018
2
2
SCALE : 3/4" = 1’−0"8
WALL REINFORCEMENT AT OPENING DETAIL
2
2
![Page 23: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/23.jpg)
M301
M30A-000
1
4
3
2
XSCALE: X"=1'-0"
TITLE
VIEW TITLE
SECTION MARKER
DETAIL CALLOUT
ELEVATION MARKER
101
1
WALL TYPE TAG
ROOM TAG
DOOR MARKER
WINDOW TYPE MARKER
REVISION MARKER
OR
001
DETAIL NO.
DETAIL NO.
DRAWING NO. DRAWING NO.
ELEVATIONNO.
KEYED NOTE
CEILING HEIGHT
DRAWING SYMBOLS
A-000
X
A-000
1
DETAIL SECTIONVIEWING DIRECTION
W1
ELEVATION NOTATIONBREAK MARKER
A-000
X
A-000
X
1
0' - 0"
1 ACCESSORY MARKER
ACM ASBESTOS CONTAINING MATERIALADJ ADJUSTABLEAFF ABOVE FINISHED FLOORALUM ALUMINUMANOD ANODIZEDARCH ARCHITECTURALAWP ACOUSTICAL WALL PANEL
B WALL BASEBO BOTTOM OF
CPT CARPETCG CORNER GUARDCJ CONTROL JOINTCL CENTER LINECLR CLEARCMU CONCRETE MASONRY UNITCO CLEAN OUTCONT CONTINUOUSCOL COLUMN
DF DRINKING FOUNTAINDIA DIAMETERDIM DIMENSIONDWG DRAWING
EA EACHEIFS EXTERIOR INSULATION
FINISHING SYSTEMEL ELEVATIONELEC ELECTRICALETR EXISTING TO REMAINEWC ELECTRIC WATER COOLEREXF EPOXY FLOORINGEXP EXPANSIONEXT EXTERIOR
FCO FLOOR CLEANOUTFD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFFE FINISHED FLOOR ELEVATIONFLR FLOORFOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTORFR FIRE RATEDFT FLOOR TILE
ABBREVIATIONSGA GAUGEGALV GALVANIZEDGL GLASSGYPBD GYPSUM BOARD
H HIGHHDR HEADERHDW HARDWAREHM HOLLOW METALHORIZ HORIZONTALHVAC HEATING/VENTILATION
AIR CONDITIONINGHW HARDWAREHWT HOT WATER TANK
ID INSIDE DIAMETERINSUL INSULATIONINT INTERIORINV INVERT
JAN CLO JANITOR'S CLOSETJT JOINT
L ANGLELVR LOUVER
MAX MAXIMUMMECH MECHANICALMFR MANUFACTURERMIN MINIMUMMO MASONRY OPENINGMTL METAL
NIC NOT IN CONTRACTNTS NOT TO SCALE
OC ON CENTEROPP OPPOSITE
PETG POLYETHYLENE TEREPHTHALATE PNT PAINTPL PLATEPLAM PLASTIC LAMINATEPLYWD PLYWOODPNL PANELPP PLASTIC PANELINGPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPT PRESSURE TREATED OR PAINT
REBAR REINFORCED STEEL BARSREF REFER/REFERENCEREINF REINFORCINGRF RESILIENT FLOORINGRM ROOMRO ROUGH OPENING
SIM SIMILARSPEC SPECIFICATIONST STAIRSSTC SOUND TRANSMISSION CLASSSTD STANDARDSTL STEELSTS STAINLESS STEELSTRUCT STRUCTURAL
T TREADTEMP TEMPORARYTH THRESHOLDTO TOP OFTOB TOP OF BEAMTOC TOP OF CONCRETETOP TOP OF PAVEMENTTOS TOP OF STEELTV TELEVISIONTYP TYPICAL
UON UNLESS OTHERWISE NOTEDUTIL UTILITY
VERT VERTICALVEST VESTIBULEVIF VERIFY IN FIELD
W WIDEWD WOODWF WIDE FLANGEWP WATERPROOFWWF WELDED WIRE FABRIC
NNORTH ARROW
1 COLUMN BUBBLE
VIEWING DIRECTION
DETAIL NO.
DRAWING NO.
DETAIL NO.
DRAWING NO. Room Name
WOOD BLOCKING (DISCONTIN.)GRAVEL OR CRUSHED STONE
WOOD FRAMING (CONTINUOUS)STEEL
PLYWOOD
CONCRETE
CONCRETE MASONRY UNIT
UNDISTURBED EARTH
MATERIAL INDICATORS
GYPSUM BOARD EXISTING TO REMAIN
FLOOR OPENINGSUBBASE
METAL TRACK
6" METAL STUDS @ 16" O.C.
EXISTING CONCRETE FLOOR/CEILING
10' - 6" +/-
+ 0' - 0"
5/8" TYPE X GYPBD EACH SIDE
EXISTING CONCRETE SLAB
METAL DEFLECTION TRACK TO ACCOMMODATE 1/2" DEFLECTION
LC BEAD, BOND BREAKER TAPEAND TYPE 1 SEALANT
BOND BREAKER TAPE AND TYPE 1 SEALANT
METAL TRACK
6" METAL STUDS @ 16" O.C.
EXISTING CONCRETE FLOOR/CEILING
10' - 6" +/-
+ 0' - 0"
METAL DEFLECTION TRACK TO ACCOMMODATE 1/2" DEFLECTION
5/8" TYPE X GYPBD EACH SIDE
FIRE-RESISTIVE JOINT SYSTEM(UL DESIGN NO. HW-S-0004)
FIRE-RESISTIVE JOINT SYSTEM(UL DESIGN NO. BW-S-0002)
EXISTING CONCRETE SLAB
METAL TRACK
6" METAL STUDS @ 16" O.C.
SECTION @ FLOOR
EXISTING CONCRETE FLOOR/CEILING
10' - 6" +/-
+ 0' - 0"
METAL DEFLECTION TRACK TO ACCOMMODATE 1/2" DEFLECTION
(2) LAYERS 5/8" TYPE X GYPBD EACH SIDE
FIRE-RESISTIVE JOINT SYSTEM(UL DESIGN NO. HW-S-0004)
FIRE-RESISTIVE JOINT SYSTEM(UL DESIGN NO. BW-S-0002)
EXISTING CONCRETE SLAB
METAL TRACK
6" METAL STUDS @16" O.C.
5/8" PLYWOOD
7' - 0"
+ 0' - 0"
METAL TRACK
TOP OF WALL
5/8" MOISTURE RESISTANT GYPBD EACH SIDE
EXISTING CONCRETE SLAB
ALUMINUM WALL CAP CONTINUOUS LENGTH OF WALL
TYPE 1 SEALANT1 1
/2"
PETG WALL PANELSEACH SIDE
A-6019
GENERAL PARTITION NOTES
1. WALL TYPES DO NOT INDICATE FINAL FINISHES. REFER TO FINISH PLANS AND FINISH SCHEDULE.2. BRACING: INSTALL CHANNEL COLD ROLLED STEEL (CRSS) BRACING AT ALL METAL STUD WALLS. INSTALL TWO ROWS OF BRACING
4'-0" O.C. FOR PARTITIONS UP TO 13'-0" HIGH.3. FIRE PARTITIONS AND FIRE BARRIERS: FIRE PARTITIONS AND FIRE BARRIERS MUST BE SIMILARLY CONSTRUCTED AS A COMPLETE
BARRIER TO RESIST THE SPREAD OF SMOKE AND FIRE. ALL PENETRATIONS MUST BE SEALED AND LABELED WITH AN APPROVED FIRE RESISTANT JOINT SYSTEM. INSTALL A FIRE RESISTANT JOINT SYSTEM AT THE HEAD AND FLOOR CONDITION OF ALL FIRE RATED PARTITIONS AND BARRIERS.
4. FIRE BARRIER / PARTITIONS LABELING: ALL FIRE WALLS SHALL BE LABELED IN LETTERS AT LEAST 2-INCHES IN HEIGHT AND NO MORE THAN 10-LINEAL FEET ALONG THE WALL. LABELS SHALL BE PLACED IN SUCH A MANNER AS TO BE OBVIOUS TO WORKERS ON BOTH SIDES OF THE WALL AND WILL READ AS FOLLOWS: "X" HR. FIRE [BARRIER] [PARTITION]. PENETRATIONS MUST BE FIRE STOPPED." PROVIDE LABELING AT 12'-0" O.C. SPACING. ELECTRICAL, MECHANICAL OR PLUMBING PENETRATIONS THROUGH FIRE-RATED WALL OR FLOOR ASSEMBLIES SHALL BE SEALED WITH A U.L. APPROVED THROUGH-PENETRATION FIRESTOP SYSTEM APPROPRIATE FOR THE RATING OF THE WALL BEING PENETRATED.
5. PROVIDE (2) #10 SMS AT EACH STUD / TRACK CONNECTION AT ALL PARTITIONS, BULK HEADS & SOFFITS NOT EXTENDING FLOOR TO DECK.
6. GYPSUM BOARD SHALL BE TYPE “X” FIRE RATED. ALL JOINTS SHALL BE FINISHED WITH TAPE AND JOINT COMPOUND. PROVIDE A LEVEL 4 FINISH AT ALL JOINTS WHICH WILL BE EXPOSED TO VIEW UPON PROJECT COMPLETION U.O.N,. PROVIDE LEVEL 3 FINISH ON ALL WALLS BEHIND WALL PANELING. PROVIDE A LEVEL 1 FINISH AT ALL JOINTS WHICH WILL REMAIN CONCEALED. PROVIDE GALVANIZED STEEL CORNER BEADS AT ALL EXPOSED CORNERS.
7. METAL TRIM: EXPOSED METAL OR NON-METALLIC J-MOLD IS NOT ACCEPTABLE.8. LOCATIONS WHERE GYPSUM BOARD PARTITIONS TERMINATE AT DISSIMILAR MATERIALS, PROVIDE A FINISH-ABLE METAL END TRIM
AND A 1/4" GAP BETWEEN TRIM AND ADJACENT MATERIAL. FILL GAP WITH BACKER ROD AND SEALANT.9. PROVIDE DEFLECTION TRACK OR CLIP AT TOP OF ALL METAL STUD PARTITIONS THAT EXTEND TO THE UNDERSIDE OF
STRUCTURAL MEMBERS OR FLOOR/ ROOF DECK.10. PROVIDE FULL HEIGHT DOUBLE STUDS AT ALL DOOR AND WINDOW JAMBS.11. REFER TO SHEET G-002 FOR RATED WALL LOCATIONS.12. THE BOTTOM EDGE OF ALL GYPSUM WALL BOARD SHALL BE INSTALLED 3/8" ABOVE THE FLOOR AND SEALED AS NOTED IN
PARTITION SECTIONS, TYP.13. PROVIDE CONTROL JOINTS IN GYPSUM BOARD/STUD PARTITION CONSTRUCTION WHERE NOTED ON SHEET A-102.14. PROVIDE CORNERBEADS AT EXTERNAL CORNERS. PROVIDE LC-BEADS (J-BEAD) AT UNPROTECTED (EXPOSED) EDGES AND WHERE
GYPSUM BOARD ABUTS DISSIMILAR MATERIALS. USE SINGLE UNJOINTED LENGTHS UNLESS OTHERWISE APPROVED BY THE DIRECTOR'S REPRESENTATIVE.
EXISTING 12" CONCRETE WALL
EXISTING CONCRETE FLOOR/CEILING
10' - 6" +/-
+ 0' - 0"
PROVIDE FIRE-RESISTIVE JOINT SYSTEM(UL DESIGN NO. 2079)
EXISTING CONCRETE SLAB
EXISTING 8" CMU WALL
EXISTING CONCRETE FLOOR/CEILING
10' - 6" +/-
+ 0' - 0"
PROVIDE FIRE-RESISTIVE JOINT SYSTEM(UL DESIGN NO. 2079)
EXISTING CONCRETE SLAB
SHEET TITLE:
APPROVED:
FIELD CHECK:
DRAWN BY:
DESIGNED BY:
PROJECT
NUMBER:
SHEET OF
DRAWING NUMBER:
MARK DATE DESCRIPTION
CONTRACT:
TITLE:
LOCATION:
CLIENT:
CONSULTANT
WARNING:
THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS
DONE UNDER THE DIRECTION OF A COMPARABLE
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
ENGINEER FOR AN ENGINEER, OR LANDSCAPE ARCHITECT
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THE NEW
YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS
A CLASS "A" MISDEMEANOR.
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
11 BEAR MOUNTAIN BRIDGE ROAD
CORTLANDT MANOR, NY
DIVISION OF MILITARY
AND NAVAL AFFAIRS
CONSTRUCTION
45558455584555845558----CCCC
06/19/2018 BID DOCUMENTS
7/2
4/2
018 3
:56:1
7 P
M
A-001A-001A-001A-001
NNNNOOOOTTTTEEEESSSS,,,, SSSSYYYYMMMMBBBBOOOOLLLLSSSS,,,, AAAANNNNDDDD
PARTITION TYPESPARTITION TYPESPARTITION TYPESPARTITION TYPES
G SPRINGER
T REESE
G SPRINGER
-
1 8
SCALE : 1 1/2" = 1’−0"1
M60 PARTITION − 6" METAL STUDS (NON−RATED)SCALE : 1 1/2" = 1’−0"
2M60−1 PARTITION − 6" METAL STUDS (1−HR RATED)
SCALE : 1 1/2" = 1’−0"3
M60−2 PARTITION − 6" METAL STUDS (2−HR RATED)
SCALE : 1 1/2" = 1’−0"4
M61−PARTIAL HEIGHT
UL DESIGN NO. U495
UL DESIGN NO. U495
SCALE : 1 1/2" = 1’−0"5
EXISTING 12" CONCRETE WALL (2−HR RATED)
SCALE : 1 1/2" = 1’−0"6
EXISTING 8" CMU WALL (2−HR RATED)
2
07/24/2018 ADDENDUM 22
REVISED DRAWING 07/24/2018
![Page 24: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/24.jpg)
911 6 3 1
A
B
C
EXIST
BOILER ROOM
B-6
EXIST
AREAWAY
B-7
EXIST
STORAGE ROOM
B-5
EXIST HIGH
VOLTAGE &
COMM ROOM
B-4
EXIST
ELEC. ROOM
B-3
EXIST
VESTIBULE
B-2
EXIST
HALL
B-1
EXIST
HALL
B-13
EXIST
LATRINE
B-14
EXIST
STORAGE
B-15
EXIST
CLASSROOM
B-16
EXIST
VESTIBULE
B-12
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
12' - 10" +/- 44' - 3" +/- 44' - 3" +/- 12' - 10" +/-
51' - 8" INCIDENTAL WORK AREA 114' - 2" WORK AREA 40' - 8" INCIDENTAL WORK AREA
27' -
7"
+/-
23' -
5"
+/-
51' -
0"
WO
RK
AR
EA
EXIST
CLASSROOM
B-8
EXIST
CLASSROOM
B-9
EXIST
CLASSROOM
B-11
EXISTING CLASSROOM
B-10
7'-1" +/-B.O. PIPE
7'-3" +/-B.O. DUCT
7'-10" +/-B.O. DUCT
9'-2" +/-B.O. BEAMS
10'-6" +/-B.O. DECK
8'-0" +/-B.O. DUCT
9'-2" +/-B.O. BEAMS
10'-6" +/-B.O. DECK
1
1 1
CLR
.
6' -
8"
4
2 2
5
3
3
11
5' - 6" +/-
22
8
8
8
8
6 7
9
10
6
12 12
19
14
EXIST ELECTRICALPANEL
EXIST ELECTRICALPANEL
A-1012
S-1015
5' - 0" +/- 5' - 0" +/-
10'-6" +/-B.O. DECK
9'-2" +/-B.O. BEAMS
1515
15 15
15 15 13
EXIST ELECTRICALPANEL
A-1013
12
1313
19
181518
18
18 18
16 16
16
17
5' - 6" +/-
11
18
1. REMOVE STEEL DOOR, HARDWARE AND FRAME. SEE SHEET H-101 FOR HANDLING AND DISPOSAL REQUIREMENTS.
2. PROVIDE OPENING IN 12-INCH CONCRETE LOAD BEARING WALL FOR WORK SHOWN ON DRAWING A-102. REFER TO STRUCTURAL DETAILS 2/S-101 AND 3/S-101.
3. REMOVE WALL AND CEILING (METAL STUD AND GYPBD). PATCH HOLES IN EXISTING CONCRETE WALLS AND SLAB WITH CEMENTITIOUS MORTAR AND GRIND SMOOTH.
4. PROVIDE OPENING IN EXISTING NON LOAD-BEARING 8-INCH CMU WALL. REMOVE CMU IN SAW-TOOTH CONFIGURATION AND INFILL WITH 8-INCH CMU END BLOCKS TO PROVIDE CLEAR DIMENSION INDICATED.
5. PROVIDE (3'-0"W X 4'-8"H +/-) OPENING IN 12-INCH CONCRETE LOAD BEARING WALL FOR WORK SHOWN ON MECHANICAL DRAWINGS TO ACCOMMODATE DUCTS. REFER TO STRUCTURAL DRAWINGS AND VERIFY OPENING SIZE WITH MECHANICAL CONTRACTOR.
6. SAWCUT AND REMOVE EXISTING 5-INCH THICK CONCRETE SLAB (AND VAPOR RETARDER) TO APPROXIMATE EXTENTS SHOWN FOR UNDERSLAB SANITARY PIPING. COORDINATE WITH PLUMBING CONTRACTOR EXACT EXTENTS REQUIRED. EARTHWORK AND PIPE INSTALLATION BY PLUMBING CONTRACTOR.
7. PROVIDE 5-INCH CONCRETE SLAB INFILL PER STRUCTURAL DETAIL 4/S-101.
8. SCRAPE EXISTING PAINT ON UNDERSIDE OF CONCRETE CEILING ABOVE TO SOUND SUBSTRATE AND PREPARE SURFACE FOR SPECIFIED FINISH. SEE SHEET A-104.
9. REMOVE AND RELOCATE (2) EXISTING STORAGE CAGES TO ROOM B-10 BUILDING 504. REFER TO LOCATIONS SHOWN ON DRAWING 1/A-103. REMOVE AND RELOCATE (2) EXISTING STORAGE CAGES TO ROOM B-10 BUILDING 505. REFER TO DRAWING 1/G-004 FOR BUILDING 505 LOCATION. REFER TO PHOTO 6 AND 7 ON SHEET G-003.
10. EXISTING STORAGE LOCKERS REMOVED BY FACILITY PRIOR TO START OF CONSTRUCTION. REFER TO PHOTOS 10, 11 AND 12 ON SHEET G-003.
11. REMOVE THIS SECTION OF CONCRETE SLAB AT ONSET OF WORK TO ALLOW PLUMBING CONTRACTOR TO VERIFY EXISTING PIPE DEPTH.
12. BOTTOM OF DUCT OR PIPE IS THE LOWEST EXISTING OBSTRUCTION OBSERVED.
13. EXISTING WALL OPENING TO REMAIN FOR DUCTWORK.
14. MODIFY GRATING TO ACCOMMODATE DUCTWORK AND PIPING. SEE DETAIL 5/S-101. COORDINATE FINAL LOCATION OF DUCTWORK AND PIPING WITH MECHANICAL AND PLUMBING CONTRACTORS.
15. INFILL EXISTING WALL OPENING WHERE EXISTING DUCTWORK IS BEING REMOVED (BY MECHANICAL CONTRACTOR) WITH NORMAL WEIGHT CONCRETE. WALL OPENINGS VARY IN SIZE FROM APPROXIMATELY 6" X 12" TO 10" X 20".
16. EXISTING PORTION OF WALL WILL REMAIN EXPOSED TO VIEW. GRIND CONCRETE SMOOTH AND PATCH WITH CEMENTITIOUS MORTAR TO PROVIDE A SMOOTH SURFACE.
17. REMOVE EXISTING 8" CMU WALL IN SAW-TOOTH CONFIGURATION (SIMILAR TO 2/A-101).
18. PROVIDE OPENING IN WALL FOR DUCT. VERIFY SIZE AND LOCATION WITH MECHANICAL CONTRACTOR.
19. MODIFY EXISTING WALL OPENING FOR DUCTWORK. COORDINATE WITH MECHANICAL CONTRACTOR FOR SIZE AND LOCATION. REFER TO DETAIL 4/A-101.
REMOVAL PLAN KEYED NOTES: X
1. REFER TO H-SERIES DRAWINGS FOR ABATEMENT REMOVALS.
2. COORDINATE DIMENSIONS WITH EXISTING FIELD CONDITIONS AND NOTIFY DIRECTOR'S REPRESENTATIVE OF INTERFERENCES, DISCREPANCIES OR OTHER UNFORESEEN CONDITIONS PRIOR TO PROCEEDING WITH THE WORK IN QUESTION.
3. DIMENSIONS NOTED WITH A PLUS/MINUS (+/-) SHOULD BE WITHIN 3-INCHES OF THE NOTED DIMENSION. NOTIFY DIRECTOR'S REPRESENTATIVE OF DISCREPANCIES.
4. PROVIDE EXISTING CONCRETE ENCASED STEEL BEAM REPAIR AS FOLLOWS:REPAIR CRACK IN CONCRETE ALONG LENGTH OF BEAM (APPROXIMATELY 1/2-INCH WIDE) USING EPOXY RESIN ADHESIVE INJECTED UNDER PRESSURE. ASSUME 100 LINEAR FEET OF REPAIR WORK NEEDED.
REMOVAL PLAN GENERAL NOTES:
10' -
6"
+/-
CLEAR
6' - 8"
4
RECEPTICAL AND DATA PORT REMOVED BY ELECTRICAL CONTRACTOR
A
B
C
EXIST
HALL
B-1
EXIST
CLASSROOM
B-8
EXIST
CLASSROOM
B-9
9 TYP
10 TYP
EXISTING OPEINING
INFILL PORTION OF EXISTINGOPENING WITH 8" CMU
REMOVE PORTION OF EXISTING8" CMU WALL FOR SCHEDULEDDUCTWORK. COORDINATE EXACTSIZE AND LOACTION WITHMECHANICAL CONTRACTOR.
SHEET TITLE:
APPROVED:
FIELD CHECK:
DRAWN BY:
DESIGNED BY:
PROJECT
NUMBER:
SHEET OF
DRAWING NUMBER:
MARK DATE DESCRIPTION
CONTRACT:
TITLE:
LOCATION:
CLIENT:
CONSULTANT
WARNING:
THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS
DONE UNDER THE DIRECTION OF A COMPARABLE
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
ENGINEER FOR AN ENGINEER, OR LANDSCAPE ARCHITECT
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THE NEW
YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS
A CLASS "A" MISDEMEANOR.
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
11 BEAR MOUNTAIN BRIDGE ROAD
CORTLANDT MANOR, NY
DIVISION OF MILITARY
AND NAVAL AFFAIRS
CONSTRUCTION
45558455584555845558----CCCC
06/19/2018 BID DOCUMENTS
7/2
4/2
018 3
:56:1
8 P
M
A-101A-101A-101A-101
BBBBAAAASSSSEEEEMMMMEEEENNNNTTTT RRRREEEEMMMMOOOOVVVVAAAALLLLSSSS
AND REPAIR PLANAND REPAIR PLANAND REPAIR PLANAND REPAIR PLAN
G SPRINGER
T REESE
G SPRINGER
-
SCALE : 1/8" = 1’−0"1
BASEMENT REMOVALS AND REPAIR PLAN N
2 8
SCALE : 1/2" = 1’−0"2
CMU WALL REMOVAL ELEVATIONSCALE : 1/8" = 1’−0"
3EXISTING CAGE LAYOUT
SCALE : 1/2" = 1’−0"4
DUCT OPENING MODIFICATION
2 07/24/2018 ADDENDUM 22
REVISED DRAWING 07/24/2018
2
![Page 25: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/25.jpg)
FD FD FD
EXIST
BOILER ROOM
B-6
EXIST
AREAWAY
B-7
EXIST
STORAGE ROOM
B-5
EXIST HIGH
VOLTAGE &
COMM ROOM
B-4
EXIST
ELEC. ROOM
B-3
EXIST
VESTIBULE
B-2
EXIST
HALL
B-1
GAME ROOM
B-9
DAY ROOM
B-11
EXIST
HALL
B-13
EXIST
LATRINE
B-14
EXIST
STORAGE
B-15
EXIST
CLASSROOM
B-16
EXISTING CLASSROOM
B-10
LAUNDRY
B-8
EXIST
VESTIBULE
B-12
MECH. ROOM
B-18
911 6 3 1
A
B
C
EXIST ELECTRICALPANEL
EXIST ELECTRICALPANEL
EXIST ELEC.PANEL
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
CLR
3' -
8"
12' - 10" +/- 44' - 3" +/- 44' - 3" +/- 12' - 10" +/-
51' - 8" INCIDENTAL WORK AREA 114' - 2" WORK AREA 40' - 8" INCIDENTAL WORK AREA
27' -
7"
+/-
23' -
5"
+/-
51' -
0"
WO
RK
AR
EA
13' - 0" 8' - 9" 12' - 4" 2' - 6" 12' - 4" 7' - 6" +/-
CORRIDOR
B-17
CLR
3' -
8"
A-5017
6' -
0"
1' -
0"
24' -
6"
+/-
18' -
6"
+/-
B-1
7BB-17A
B-8
A
B-8
BB
-9A
B-1
1A
B-1
0B
B-1
0A
B-1
7D B-17C
M60-1
M60 M
61
M61
M60-1
M60-1
W1
B-1
8
B-1
B-9
B
B-1
1C
B-1
1B
B-13
8
4' -
10"
13' -
8"
M60-2
M60-2
M60-2
M60-2
2
33
4
5 5 5
7
6
6' -
0"
3' -
6"
5
A-401
EQ EQ
A-401 4 A-401 1
A-5011
M60-1
M60-1
M60-1
M60-1
A-5013
A-5012
A-401 2
5 5 5
9
A-5018
A-5018
1
9 9
A-5019
MIRRA-501
9
1
5
10 10 10
5
5
11
1111
11
1212
12
12 12
12
11
5
16' - 7" 22' - 9" 16' - 10" 15' - 0" 15' - 0" 15' - 0"
1. SEE INTERIOR ELEVATIONS 2 AND 3 ON SHEET A-102 FOR ADDITIONAL INFORMATION.
2. UNDER SLAB LINT SEPARATOR ACCESS COVER PROVIDED BY PLUMBING CONTRACTOR.
3. ALIGN GYPBD WITH FACE OF EXISTING MASONRY WALL.
4. PROVIDE BOX OUT IN WALL TO ACCOMMODATE DUCTWORK. COORDINATE EXACT SIZE AND LOCATION WITH MECHANICAL CONTRACTOR.
5. PROVIDE CONTROL JOINT IN GYPBD SUBMIT SHOP DRAWING OF DIMENSIONS AND LOCATIONS.
6. PROVIDE BACKER ROD AND ACOUSTIC SEALANT ON BOTH SIDES OF WALL.
7. PROVIDE ACOUSTIC SEALANT AT WALL PENETRATIONS.
8. PROVIDE 8" CMU BLOCK INFILL IN SAW-TOOTH CONFIGURATION AT EXISTING DOOR OPENING. SECURE CMU TO EXISTING WITH BUCK ANCHORS EVERY OTHER COURSE.
9. SLOPE RESINOUS FLOORING FROM 3/8" THICK TO 1/4" THICK TO PROVIDE POSITIVE DRAINAGE TO FLOOR DRAINS.
10. FLOOR DRAIN PROVIDED BY PLUMBING CONTRACTOR.
11. EXISTING WALL OPENING TO REMAIN FOR DUCTWORK.
12. SCHEDULED WALL OPENING FOR DUCTWORK. REFER TO SHEET A-101 FOR ADDITIONAL INFORMATION.
PLAN KEYED NOTES: X
1. DIMENSIONS FOR STUD PARTITIONS ARE TO FACE OF STUD. DIMENSIONS FOR MASONRY WALLS ARE TO FACE OF MASONRY. DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FINISHED FACE OF CONSTRUCTION.
2. DIMENSIONS NOTED AS “CLR” ARE TO FINISHED SURFACE AND ARE CRITICAL FOR CODE REQUIREMENTS OR BUILT-IN FURNISHINGS.
3. COORDINATE DIMENSIONS WITH EXISTING FIELD CONDITIONS AND NOTIFY DIRECTOR'S REPRESENTATIVE OF INTERFERENCES, DISCREPANCIES OR OTHER UNFORESEEN CONDITIONS PRIOR TO PROCEEDING WITH THE WORK IN QUESTION.
4. FIELD VERIFY FINISHED DIMENSIONS AND CLEARANCES IN SPACES INDICATED TO RECEIVE BUILT-IN FURNISHINGS OR CASEWORK PRIOR TO FABRICATION.
5. DIMENSIONS NOTED WITH A PLUS/MINUS (+/-) SHOULD BE WITHIN 3-INCHES OF THE NOTED DIMENSION. NOTIFY DIRECTOR'S REPRESENTATIVE OF DISCREPANCIES.
6. EXISTING WALL PENETRATIONS THROUGH EXISTING CMU AND CONCRETE WALLS NOTED ON SHEET G-003 REQUIRING FIRE-RESISTANT RATING, REQUIRE THE FOLLOWING WORK:
A. REMOVE EXISTING FILL MATERIAL FROM APPROXIMATELY 200 PENETRATIONS (EACH AT DIFFERENT LOCATIONS) VARYING IN DIAMETER FROM APPROXIMATELY 1" TO 6". PROVIDE A FIRE-STOPPING SYSTEM EQUAL TO THE REQUIRED WALL FIRE-RESISTANCE RATING.
B. PROVIDE FIRE-STOPPING JOINT SYSTEM AT THE HEAD OF WALL AS NOTED ON DETAILS 5 AND 6 ON SHEET A-001.
PLAN GENERAL NOTES:
7' -
2"
10' -
6"
+/-
B-17B
EXISTING CONCRETE WALL
EXISTING PIPING (SEE PHOTO 4/G-003)WITH FIRESTOPPING PROVIDED ATPARTITION
CORNER GUARD
SCHEDULED BASE
SCHEDULED DOOR AND HARDWARE
SCHEDULED PARTITION
STEEL REINFORCEMENT AT WALL OPENING(REFER TO STRUCTURAL DRAWINGS)
A-1045
B-17D
8' -
2"
10' -
6"
+/-
EXISTING CONCRETE WALL
EXISTING PIPING (SEE PHOTO 2/G-003)WITH FIRESTOPPING PROVIDED ATPARTITION
CORNER GUARD
SCHEDULED BASE
SCHEDULED DOOR AND HARDWARE
SCHEDULED PARTITION
STEEL REINFORCEMENT AT WALL OPENING (REFER TO STRUCTURAL DRAWINGS)
A-1044
DUCTWORK BY MECHANICALCONTRACTOR
SHEET TITLE:
APPROVED:
FIELD CHECK:
DRAWN BY:
DESIGNED BY:
PROJECT
NUMBER:
SHEET OF
DRAWING NUMBER:
MARK DATE DESCRIPTION
CONTRACT:
TITLE:
LOCATION:
CLIENT:
CONSULTANT
WARNING:
THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS
DONE UNDER THE DIRECTION OF A COMPARABLE
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
ENGINEER FOR AN ENGINEER, OR LANDSCAPE ARCHITECT
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THE NEW
YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS
A CLASS "A" MISDEMEANOR.
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
11 BEAR MOUNTAIN BRIDGE ROAD
CORTLANDT MANOR, NY
DIVISION OF MILITARY
AND NAVAL AFFAIRS
CONSTRUCTION
45558455584555845558----CCCC
06/19/2018 BID DOCUMENTS
7/2
4/2
018 3
:56:1
9 P
M
A-102A-102A-102A-102
BBBBAAAASSSSEEEEMMMMEEEENNNNTTTT FFFFLLLLOOOOOOOORRRR PPPPLLLLAAAANNNN
G SPRINGER
T REESE
G SPRINGER
-
SCALE : 1/8" = 1’−0"1
BASEMENT FLOOR PLAN
N
3 8
SCALE : 1/2" = 1’−0"2
INTERIOR ELEVATION AT DOOR B−17BSCALE : 1/2" = 1’−0"
3INTERIOR ELEVATION AT DOOR B−17D
2
07/24/2018 ADDENDUM 22
REVISED DRAWING 07/24/2018
22
2
![Page 26: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/26.jpg)
911 6 3 1
A
B
C
EXIST
BOILER ROOM
B-6
EXIST
STORAGE ROOM
B-5
EXIST HIGH
VOLTAGE &
COMM ROOM
B-4
EXIST
ELEC. ROOM
B-3
EXIST
VESTIBULE
B-2
EXIST
HALL
B-1
GAME ROOM
B-9
DAY ROOM
B-11
EXISTING CLASSROOM
B-10
MECH. ROOM
B-18
EXIST
HALL
B-13
EXIST
LATRINE
B-14
EXIST
STORAGE
B-15
EXIST
CLASSROOM
B-16
EXIST
AREAWAY
B-7
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
LAUNDRY
B-8
UNEXCAVATED
1 1 1
1 1
1
2
2
2
2
ERV-1
MAU-1
FCU-1 FCU-2
CORRIDOR
B-17
2
A-104
5
A-1042
A-104SIM
2
3
A-104
4
A-104
3
A-104
1. EXISTING PIPING AND NOT ALL SCHEDULED DEVICES SHOWN FOR CLARITY. REFER TO PHOTOS ON SHEET G-003 FOR EXISTING CONDITIONS.
2. EXISTING CEILING PENETRATIONS THROUGH THE EXISTING CONCRETE SLAB NOT SHOWN ON CEILING. INCLUDED WITHIN THE WORK IS THE FOLLOWING:
A. REMOVE EXISTING FILL MATERIAL FROM THE ANNULAR SPACE FROM APPROXIMATELY 90 PENETRATIONS WITHIN THE WORK AREA (EACH AT DIFFERENT LOCATIONS) VARYING IN DIAMETER FROM APPROXIMATELY 1" TO 6". PROVIDE A 2-HR INTUMESCENT FIRE-STOPPING SYSTEM (UL DESIGN NO. C-AJ-1184) AT THE EXISTING PENETRATIONS FOR A ONE-SIDED INSTALLATION.
3. MECHANICAL, ELECTRICAL AND PLUBMING SYSTEMS SHOW IN THEIR ENTIRETY FORREFERENCE AND CLARITY.
CEILING PLAN GENERAL NOTES:
LIGHT FIXTURE BY E-CONTRACT
EXISTING LIGHT FIXTURE TO REMAIN
DUCTWORK BY H-CONTRACT
EXISTING DUCTWORK TO REMAIN
SPRINKLER HEAD BY P-CONTRACT
CEILING PLAN SYMBOL LEGEND:
1. PAINT CONCRETE CEILING, AND ALL SCHEDULED AND EXISTING PIPING, DUCTWORK, CONDUITS AND WIRING. SEE MECHANICAL, PLUMBING, AND ELECTRICAL CONTRACT DRAWINGS FOR ADDITIONAL EXISTING TO REMAIN ITEMS AND SCHEDULED ITEMS THAT REQUIRE PAINTING WITHIN THE C-CONTRACT. REFER TO PHOTOS ON SHEET G-003 FOR EXISTING CONDITIONS.
2. PAINT DUCTWORK IN THIS SPACES THAT IS OUTSIDE OF WORK AREA.
CEILING PLAN KEYED NOTES: X10' - 6" +/-
BOTTOM OF SLAB
9' - 2" +/-
BOTTOM OF CONCRETE BEAM BEYOND
8' - 2"
TOP OF OPENING INCONCRETE WALL
7' - 6"
BOTTOM OF DUCT
STEEL DOOR FRAME
DUCTWORK BEYOND BY MECHANICAL CONTRACTORSHOWN FOR REFERENCE
6" METAL STUDS @ 16" OC
CONCRETE BEAM BEYOND
EXISTING 12" CONCRETE WALL
EXISTING CONCRETE FLOOR SLAB ABOVE
5/8" TYPE X GYPBD EACH SIDE
STEEL REINFORCEMENT AT WALL OPENING(REFER TO STRUCTURAL DRAWINGS)
FIRESTOPPING JOINT SYSTEM
BACKER ROD AND TYPE 1D SEALANT
2-5/8" METAL STUDS @ 16" OC
5/8" TYPE X GYPBD
COORDINATE INSTALLATION OF SOFFIT WITH INSTALLATION OF FIRESTOPPING JOINT SYSTEM AT HEAD OF WALL AND COORDINATE REVIEW OF FIRESTOPPING WITH DIRECTOR'S REPRESENTATIVE PRIOR TO ENCLOSING SOFFIT.
10' - 6" +/-
BOTTOM OF SLAB
7' - 6"
BOTTOM OF DUCT
STEEL DOOR FRAME
DUCTWORK BEYOND BY MECHANICAL CONTRACTORSHOWN FOR REFERENCE
6" METAL STUDS @ 16" OC
5/8" TYPE X GYPBD
BACKER ROD AND TYPE 1D SEALANT
EXISTING CONCRETE FLOOR SLAB ABOVE
5/8" TYPE X GYPBD EACH SIDE
2-5/8" METAL STUDS @16" OC
FIRESTOPPING JOINT SYSTEM
BACKER ROD AND TYPE 1D SEALANT
2-5/8" METAL STUDS @ 16" OC
5/8" TYPE X GYPBD
COORDINATE INSTALLATION OF SOFFIT WITH INSTALLATION OF FIRESTOPPING JOINT SYSTEM AT HEAD OF WALL
10' - 6" +/-
BOTTOM OF SLAB
9' - 2" +/-
BOTTOM OF CONCRETE BEAM BEYOND
8' - 2"
TOP OF OPENING INCONCRETE WALL
7' - 8"
BOTTOM OF DUCT
DUCTWORK BEYOND BY MECHANICAL CONTRACTORSHOWN FOR REFERENCE
CONCRETE BEAM BEYOND
EXISTING 12" CONCRETE WALL
EXISTING CONCRETE FLOOR SLAB ABOVE
STEEL REINFORCEMENT AT WALL OPENING(REFER TO STRUCTURAL DRAWINGS)
BACKER ROD AND TYPE 1D SEALANT
2-5/8" METAL STUDS @ 16" OC
5/8" TYPE X GYPBD BOTH SIDES7' - 0" +/-
BOTTOM OF SOFFIT 2-5/8" STRAP BRACING AT EACH STUD
5/8" TYPE X GYPBD
10' - 6" +/-
BOTTOM OF SLAB
9' - 2" +/-
BOTTOM OF CONCRETE BEAM BEYOND
7' - 2"
TOP OF OPENING INCONCRETE WALL
CONCRETE BEAM BEYOND
EXISTING 12" CONCRETE WALL
EXISTING CONCRETE FLOOR SLAB ABOVE
STEEL REINFORCEMENT AT WALL OPENING(REFER TO STRUCTURAL DRAWINGS)
BACKER ROD AND TYPE 1D SEALANT
1-1/2" METAL FURRING STRIPS
7' - 0" +/-
BOTTOM OF SOFFIT
5/8" TYPE X GYPBD BOTH SIDES
5/8" TYPE X GYPBD
SHEET TITLE:
APPROVED:
FIELD CHECK:
DRAWN BY:
DESIGNED BY:
PROJECT
NUMBER:
SHEET OF
DRAWING NUMBER:
MARK DATE DESCRIPTION
CONTRACT:
TITLE:
LOCATION:
CLIENT:
CONSULTANT
WARNING:
THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS
DONE UNDER THE DIRECTION OF A COMPARABLE
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
ENGINEER FOR AN ENGINEER, OR LANDSCAPE ARCHITECT
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THE NEW
YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS
A CLASS "A" MISDEMEANOR.
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
11 BEAR MOUNTAIN BRIDGE ROAD
CORTLANDT MANOR, NY
DIVISION OF MILITARY
AND NAVAL AFFAIRS
CONSTRUCTION
45558455584555845558----CCCC
06/19/2018 BID DOCUMENTS
7/24/2018 5:35:51 PM
A-104A-104A-104A-104
BBBBAAAASSSSEEEEMMMMEEEENNNNTTTT CCCCEEEEIIIILLLLIIIINNNNGGGG PPPPLLLLAAAANNNN
G SPRINGER
T REESE
G SPRINGER
-
SCALE : 1/8" = 1’−0"1
BASEMENT CEILING PLAN N
5 8
SCALE : 3/4" = 1’−0"2
SOFFIT DETAIL
07/24/2018 ADDENDUM 22
SCALE : 3/4" = 1’−0"3
SOFFIT DETAIL
REVISED DRAWING 07/24/2018
2
2
2
SCALE : 3/4" = 1’−0"4
SOFFIT DETAILSCALE : 3/4" = 1’−0"
5SOFFIT DETAIL
22
2
![Page 27: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/27.jpg)
EXISTING LIGHT FIXTURES TO REMAIN
DRYER EXHAUST DUCT BY MECHANICAL CONTRACTOR
PROVIDE FIRE EXTINGUISHER CABINET AND TENT SIGN BEYOND
EXISTING PIPING TO REMAIN. APPROXIMATE LOCATIONS SHOWN FOR REFERENCE.
7' -
0"
7' -
1"
+/-
RESINOUS COVE BASE
PETG PANEL JOINT
OPEN
4' - 0"
METAL CAP
7' -
9"
+/-
10' -
6"
+/-
9' -
2"
+/-
OPEN
13' - 8" 4' - 4"
BOTTOM OF CONCRETE BEAM BEYOND
METAL PIPE ENCLOSURE
8
A-501
SPRINKLER PIPING BY PLUMBING CONTRACTOR
PETG WALL PANEL
11
A-501
SINK AND CONTROLS BY PLUMBING CONTRACTOR
3' -
0"
3' -
0"
7' -
4"
DUCTWORK BY MECHANICALCONTRACTOR
SPRINKLER PIPING BY PLUMBING CONTRACTOR
LAUNDRY
B-8
CORRIDOR
B-17
CLEAR
1' - 10 3/4"
2' - 6"
DRYERDRYER
DUCT PROVIDEDBY MECHANICALCONTRACTOR
DUCT PROVIDEDBY MECHANICALCONTERACTOR
3-5/8" 20GA STRAP BRACING
ALUMINUM CAP
12" DUCT
3-5/8" METAL STUDS @ 16" OC
5/8" TYPE MOISTURE RESISTANT GYPBD
EXISTING LIGHTFIXTURES TOREMAIN
A-50110
RESINOUS COVE BASE
RESINOUS COVE BASE
PETG PANEL JOINT
METAL CAP
4' -
0"
7' -
9"
+/-
10' -
6"
+/-
7' -
1"
+/-
4' - 0"
9' -
2"
+/-
EXISTING LIGHTFIXTURES TOREMAIN
DRYER EXHAUST DUCT BY MECHANICAL CONTRACTOR
PROVIDE FIRE EXTINGUISHER CABINET AND TENT SIGN BEYOND
EXISTING PIPING TO REMAIN. APPROXIMATE LOCATIONS SHOWN FOR REFERENCE.
BOTTOM OF CONCRETE BEAM BEYOND
OPEN
OPEN
13' - 8" 4' - 4"
OUTLET BY ELECTRICAL CONTRACTOR TYP
DUCT BY MECHANICAL CONTRACTOR TYP
SPRINKLER PIPING BY PLUMBING CONTRACTOR
PETG WALL PANEL 7' -
4"
DUCTWORK BY MECHANICALCONTRACTOR
SPRINKLER PIPING BY PLUMBING CONTRACTOR
LAUNDRY
B-8
CORRIDOR
B-17
7" 7"
SCHEDULED OPENING
3' - 1" +/-
5' -
4"
SC
HE
DU
LE
D O
PE
NIN
G
4' -
2"
+/-
1' -
0"
6' -
0"
EX
IST
ING
2' -
4"
+/-
2' -
2"
1' - 3"
EXISTING OPENING
7' - 8" +/-1' - 9"
OP
EN
ING
EXISTING DOOR
DUCT, LOUVER AND INFILL PANELS BY MECHANICAL CONTRACTOR
DUCT, LOUVER AND INFILL PANEL BY MECHANICAL CONTRACTOR
WALL REINFORCEMENT(REFER TO STRUCTURAL DRAWING S-101)
EXISTING LIGHT FIXTURES TO REMAIN
PROVIDE FIRE EXTINGUISHER CABINET AND TENT SIGN BEYOND
EXISTING PIPING TO REMAIN. APPROXIMATE LOCATIONS SHOWN FOR REFERENCE.
RESINOUS COVE BASE
PETG PANEL JOINT
OPENMETAL CAP
OPEN
BOTTOM OF CONCRETE BEAM BEYOND
METAL PIPE ENCLOSURE
7' -
9"
+/-
10' -
6"
+/-
7' -
0"
7' -
1"
+/-
9' -
2"
+/-
13' - 8" 4' - 4"
4' - 0"
WASHER BOX PROVIDED BY PLUMBING CONTRACTORTYP
OUTLET BY ELECTRICAL CONTRACTOR TYP
8
A-501
PETG WALL PANEL
SPRINKLER PIPING BY PLUMBING CONTRACTOR
11
A-501
7' -
4"
DUCTWORK BY MECHANICALCONTRACTOR
SPRINKLER PIPING BY PLUMBING CONTRACTOR
CORRIDOR
B-17
LAUNDRY
B-8
SHEET TITLE:
APPROVED:
FIELD CHECK:
DRAWN BY:
DESIGNED BY:
PROJECT
NUMBER:
SHEET OF
DRAWING NUMBER:
MARK DATE DESCRIPTION
CONTRACT:
TITLE:
LOCATION:
CLIENT:
CONSULTANT
WARNING:
THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS
DONE UNDER THE DIRECTION OF A COMPARABLE
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
ENGINEER FOR AN ENGINEER, OR LANDSCAPE ARCHITECT
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THE NEW
YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS
A CLASS "A" MISDEMEANOR.
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
11 BEAR MOUNTAIN BRIDGE ROAD
CORTLANDT MANOR, NY
DIVISION OF MILITARY
AND NAVAL AFFAIRS
CONSTRUCTION
45558455584555845558----CCCC
06/19/2018 BID DOCUMENTS
7/2
4/2
018 3
:56:2
0 P
M
A-401A-401A-401A-401
IIIINNNNTTTTEEEERRRRIIIIOOOORRRR EEEELLLLEEEEVVVVAAAATTTTIIIIOOOONNNNSSSS AAAANNNNDDDD
SECTIONSSECTIONSSECTIONSSECTIONS
G SPRINGER
T REESE
G SPRINGER
-
6 8
SCALE : 1/2" = 1’−0"4
LAUNDRY ROOM SERVICE SINK WALL ELEVATIONSCALE : 1/2" = 1’−0"
3PARTIAL HEIGHT WALL SECTION
SCALE : 1/2" = 1’−0"1
LAUNDRY ROOM DRYER WALL ELEVATION
SCALE : 1/2" = 1’−0"5
EXISTING AREAWAY B−7 SECTION
SCALE : 1/2" = 1’−0"2
LAUNDRY ROOM WASHER WALL ELEVATION
07/24/2018 ADDENDUM 22
REVISED DRAWING 07/24/2018
2
2
2
2
![Page 28: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/28.jpg)
3' -
2"
5' - 0" +/- 0' - 11" 0' - 11" 5' - 0" +/-
3' -
2"
B-9
A
B-1
1A
A-5014
A-6014
TYP
A-5015
CLR
1' - 6"
CLR
1' - 6"
CORNER GUARDS, TYP
5' - 0" +/-
CLR
1' - 6"
3' -
2"
B-1
0A
A-6016
CORNER GUARDS, TYP
1' - 5" 5' - 0" +/-
CLR
1' - 6"
3' -
2"
B-1
0B
A-5016
CORNER GUARD, TYP
D
DUCT PROVIDED BYMECHANICAL CONTRACTOR
12" DRYER EXHAUST DUCT BY MECHANICAL CONTRACTOR
CLEAR
1' - 10 3/4"DUCT PROVIDED BYMECHANICAL CONTRACTORTYP 2' - 6"
D
D
D
D
D
D
D
D
D
3-5/8" 20 GA METAL BRACING AT EACH STUD
3
A-401
A-401 1
13' -
8"
ALUMINUM WALL CAPADHERED TO SUBSTRATE
5/8" FIRE TREATED PLYWOOD
TYPE 1 SEALANT
3-5/8" 20GA STRAPBRACING 16" OC (COORDLOCATION WITH MECHCONTRACTOR)
3-5/8" 20GA METAL STUDS @ 16" OC
5/8" MOISTURE RESISTANT GYPBD
1 1
/2"
PETG WALL PANEL
FIRE-RESISTIVE JOINT SYSTEM
5/8" TYPE X GYPBD
DOUBLE STUD TYP @ JAMB
STEEL DOOR FRAME
1" GYP LINER PANEL
6" METAL C-H STUD TYP @GYP LIINER PANEL
5/8" TYPE X GYPBD
EXISTING 8" CMU WALL
MINERAL WOOL INSULATIONWITH SEALANT ON ROOM SIDE OF SAME TYPE REQUIRED ATFIRE-RESISTIVE JOINT SYSTEMS.THIS LOCATION IS NOT REQUIREDTO BE FIRE-RATED AND IS PROVIDEDFOR CONSISTENCY PURPOSES
1" GYP LINER PANEL
4"
4"
6" METAL J-RUNNER TYP @ ENDOF GYP LINER PANEL
CORNER GUARD
EXISTING CONCRETE WALL
1' -
0"
+/-
5/8" TYPE X GYPBD EACH SIDE
6" METAL STUDS @ 16" O.C.
FIRE-RESISTIVE JOINT SYSTEM
CORNER GUARD
CEMENTITIOUS MORTAR TO PROVIDE SMOOTH SURFACE
CEMENTITIOUS MORTAR TO PROVIDE SMOOTH SURFACE
EXISTING CONCRETE WALL
5/8" TYPE X GYPBD
6" METAL J-RUNNER TYP@ END OF GYP LINER PANEL
6" METAL C-H STUD TYP@ GYP LINER PANEL
1" GYP LINER PANEL
4"
STEEL DOOR FRAME
DOUBLE STUD TYP @ JAMB
5/8" TYPE X GYPBD
EXISTING 8" CMU WALL
FIRE-RESISTIVE JOINT SYSTEM
CORNER GUARD
4"
1" GYP LINER PANEL
WALL BELOW
PETG PANEL
5/8" MOISTURE RESISTANTGYPBD
6" METAL STUDS
VENT PIPE BY PLUMBINGCONTRACTOR
1' -
0"
6"
EXISTING CONCRETE WALL
1' -
0"
+/-
(2) LAYERS 5/8" TYPE X GYPBD EACH SIDE
FIRE-RESISTIVE JOINT SYSTEM
CORNER GUARD
DOUBLE STUD AT JAMB,TYP
STEEL DOOR FRAME
CEMENTITIOUS MORTAR TO PROVIDE SMOOTH SURFACE
WALL BELOW
ALUMINUM CLIP ANGLE SECURED TO CONCRETE WALL
EXISTING CONCRETE WALL
ALUMINUM PIPE ENCLOSURE (CONTINUOUS), SECURED TO CLIP ANGLES AT 4 LOCATIONS WITH #10 PAN HEAD SCREWS
PIPING BY PLUMBING CONTRACTOR
2"
6"
SHEET TITLE:
APPROVED:
FIELD CHECK:
DRAWN BY:
DESIGNED BY:
PROJECT
NUMBER:
SHEET OF
DRAWING NUMBER:
MARK DATE DESCRIPTION
CONTRACT:
TITLE:
LOCATION:
CLIENT:
CONSULTANT
WARNING:
THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS
DONE UNDER THE DIRECTION OF A COMPARABLE
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
ENGINEER FOR AN ENGINEER, OR LANDSCAPE ARCHITECT
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THE NEW
YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS
A CLASS "A" MISDEMEANOR.
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
11 BEAR MOUNTAIN BRIDGE ROAD
CORTLANDT MANOR, NY
DIVISION OF MILITARY
AND NAVAL AFFAIRS
CONSTRUCTION
45558455584555845558----CCCC
06/19/2018 BID DOCUMENTS
7/2
4/2
018 3
:56:2
0 P
M
A-501A-501A-501A-501
EEEENNNNLLLLAAAARRRRGGGGEEEEDDDD PPPPLLLLAAAANNNNSSSS AAAANNNNDDDD
DETAILSDETAILSDETAILSDETAILS
G SPRINGER
T REESE
G SPRINGER
-
7 8
SCALE : 1/2" = 1’−0"1
ENLARGED PLAN 1SCALE : 1/2" = 1’−0"
2ENLARGED PLAN 3
SCALE : 1/2" = 1’−0"3
ENLARGED PLAN 2
SCALE : 1/2" = 1’−0"7
LAUNDRY ROOM PARTIAL HEIGHT WALL PLAN DETAIL
SCALE : 1 1/2" = 1’−0"10
ALUMINUM WALL CAP DETAIL
SCALE : 1 1/2" = 1’−0"6
PLAN DETAIL 3
SCALE : 1 1/2" = 1’−0"4
PLAN DETAIL 1
SCALE : 1 1/2" = 1’−0"5
PLAN DETAIL 2
SCALE : 1 1/2" = 1’−0"8
PLAN DETAIL 4SCALE : 1 1/2" = 1’−0"
9PLAN DETAIL 5
SCALE : 1 1/2" = 1’−0"11
PIPE ENCLOSURE DETAIL
2
07/24/2018 ADDENDUM 22
REVISED DRAWING 07/24/2018
![Page 29: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/29.jpg)
F
FLUSH
SCHEDULE
SEE
SE
E S
CH
ED
ULE
NG
NARROW GLASS
5" 8"SCHEDULE
SEE
1' -
2"
1' -
8"
SE
E S
CH
ED
ULE SCHEDULED
GLASS
1
SE
E S
CH
ED
ULE
4" SCHEDULE
SEE2" 2"
W1
TYPE G GLASSROOM SIDE
STEEL WINDOW
3' -
0"
4' -
0"
4' - 0" 4' - 0"
8' - 0"
2" 2"
WELDED ANCHORS
STEEL DOOR FRAME
1/2
"
TYP.UON
2"
5/8"
DOUBLE STUDS TYP @ JAMBS
SEE WALL TYPES FOR WALL CONSTRUCTION & MATERIALS
SEALANT AT PERIMETER(BOTH SIDES, TYP)
4"
DASHED LINE REPRESENTS WALL WHERE APPLICABLE
CPT RF
SCHEDULED DOOR
1 1/2"
EXISTING CONCRETECPT
SCHEDULED DOOR
WELDED ANCHORS
STEEL DOOR FRAME
1/2
"
2"
5/8"
SEE WALL TYPES FOR WALL CONSTRUCTION & MATERIALS
SEALANT AT PERIMETER(BOTH SIDES, TYP)
EXISTING CMU WALL
4"
FIRE-RESISTIVE JOINT SYSTEM (BOTH SIDES, TYP)
WELDED ANCHORS
STEEL DOOR FRAME
1/2
"
TYP.UON
2"
5/8"
DOUBLE STUDS TYP @ JAMBS
SEE WALL TYPES FOR WALL CONSTRUCTION & MATERIALS
SEALANT AT PERIMETER(BOTH SIDES, TYP)
4"
DASHED LINE REPRESENTS WALL WHERE APPLICABLE
RESINOUS FLOORING
RESINOUS COVE BASE
4"
METAL COVE STRIP
PETG WALL PANEL WHEREAPPLICABLE
WALL CONSTRUCTION VARIESREFER TO FLOOR PLANS AND WALL TYPES
SHEET TITLE:
APPROVED:
FIELD CHECK:
DRAWN BY:
DESIGNED BY:
PROJECT
NUMBER:
SHEET OF
DRAWING NUMBER:
MARK DATE DESCRIPTION
CONTRACT:
TITLE:
LOCATION:
CLIENT:
CONSULTANT
WARNING:
THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS
DONE UNDER THE DIRECTION OF A COMPARABLE
PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT,
ENGINEER FOR AN ENGINEER, OR LANDSCAPE ARCHITECT
FOR A LANDSCAPE ARCHITECT, IS A VIOLATION OF THE NEW
YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS
A CLASS "A" MISDEMEANOR.
PROVIDE LAUNDRY ROOM & DAY ROOM
BUILDING 504
CAMP SMITH TRAINING SITE
11 BEAR MOUNTAIN BRIDGE ROAD
CORTLANDT MANOR, NY
DIVISION OF MILITARY
AND NAVAL AFFAIRS
CONSTRUCTION
45558455584555845558----CCCC
06/19/2018 BID DOCUMENTS
7/2
4/2
018 3
:56:2
1 P
M
A-601A-601A-601A-601
DDDDOOOOOOOORRRR SSSSCCCCHHHHEEEEDDDDUUUULLLLEEEE,,,, DDDDOOOOOOOORRRR
AAAANNNNDDDD FFFFRRRRAAAAMMMMEEEE TTTTYYYYPPPPEEEESSSS
G SPRINGER
T REESE
G SPRINGER
-
SCALE : 1/4" = 1’−0"
DOOR TYPESSCALE : 1/4" = 1’−0"
DOOR FRAME TYPES
DOOR SCHEDULE
DO
OR
#
ROOM
NAME
DOOR FRAME DETAILS
GL
AS
S T
YP
E
SE
CU
RE
FIR
E R
AT
ING
HARDWARE
REMARKS DO
OR
#
SIZE
TY
PE
MA
TE
RIA
L-F
INIS
H
TY
PE
MA
TE
RIA
L-F
INIS
H
AN
CH
OR
S
HE
AD
JA
MB
SIL
L
SE
T #
HA
ND
KE
YS
IDE
CO
VE
RP
LA
TE
WID
TH
HE
IGH
T
TH
ICK
NE
SS
BASEMENT FLOOR PLAN
B-1 CORRIDOR 3' - 0" 7' - 0" 1 3/4" NG ETR - PT 1 ETR - PT ETR ETR ETR ETR ETR NO 90 ETR ETR ETR - 1, 2 (EXISTING) B-1
B-8A LAUNDRY 3' - 0" 7' - 0" 1 3/4" NG STL - PT 1 STL - PT WELD-IN - 4/A-601 - G YES 20 1 LH ENTRY - - B-8A
B-8B LAUNDRY 3' - 0" 7' - 0" 1 3/4" NG STL - PT 1 STL - PT WELD-IN - 4/A-601 - G YES 20 1 RH ENTRY - - B-8B
B-9A GAME ROOM 3' - 0" 7' - 0" 1 3/4" NG STL - PT 1 STL - PT WELD-IN - 4/A-601 7/A-601 G YES 20 2 RH ENTRY - - B-9A
B-9B GAME ROOM 3' - 0" 7' - 0" 1 3/4" NG ETR - PT 1 ETR - PT ETR ETR ETR 7/A-601 ETR YES 90 ETR ETR ETR - 1 (EXISTING) B-9B
B-10A EXISTINGCLASSROOM
3' - 0" 7' - 0" 1 3/4" NG STL - PT 1 STL - PT WELD-IN - 4/A-601 - G YES 20 3 LH ENTRY - - B-10A
B-10B EXISTINGCLASSROOM
3' - 0" 7' - 0" 1 3/4" NG STL - PT 1 STL - PT WELD-IN - 4/A-601 - G YES 20 4 RH ENTRY - - B-10B
B-11A DAY ROOM 3' - 0" 7' - 0" 1 3/4" NG STL - PT 1 STL - PT WELD-IN - 4/A-601 7/A-601 G YES 20 2 LH ENTRY - - B-11A
B-11B DAY ROOM 3' - 0" 7' - 0" 1 3/4" NG ETR - PT 1 ETR - PT ETR ETR ETR 7/A-601 ETR YES 90 ETR ETR ETR - 1 (EXISTING) B-11B
B-11C DAY ROOM 3' - 0" 7' - 0" 1 3/4" NG ETR - PT 1 ETR - PT ETR ETR ETR ETR ETR ETR - ETR ETR ETR - 1 (EXISTING) B-11C
B-13 CORRIDOR 3' - 0" 7' - 0" 1 3/4" NG ETR - PT 1 ETR - PT ETR ETR ETR ETR ETR ETR 90 ETR ETR ETR - 1, 2 (EXISTING) B-13
B-17A CORRIDOR 3' - 0" 7' - 0" 1 3/4" NG STL - PT 1 STL - PT WELD-IN - 5/A-601 - G YES 90 5 RH ENTRY - - B-17A
B-17B CORRIDOR 4' - 0" 7' - 0" 1 3/4" F STL - PT 1 STL - PT WELD-IN - 5/A-601 - - YES 90 6 LH +RH ENTRY - - B-17B
B-17C CORRIDOR 3' - 0" 7' - 0" 1 3/4" NG STL - PT 1 STL - PT WELD-IN - 5/A-601 - G YES 90 5 LH ENTRY - - B-17C
B-17D CORRIDOR 4' - 0" 7' - 0" 1 3/4" F STL - PT 1 STL - PT WELD-IN - 5/A-601 - - YES 90 6 LH +RH ENTRY - - B-17D
B-18 MECH. ROOM 3' - 0" 7' - 0" 1 3/4" F STL - PT 1 STL - PT WELD-IN - 4/A-601 - - YES 20 5 LH ENTRY - - B-18
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR BASE
WALLS
CEILING REMARKSNORTH SOUTH EAST WESTBASEMENT FLOOR PLAN
B-8 LAUNDRY RF RCB PT PETG PETG/PT PT PT 1, 2, 4, 5
B-9 GAME ROOM CPT RB PT PT PT PT PT 3, 4
B-10 EXISTING CLASSROOM ETR ETR ETR ETR PT ETR ETR
B-11 DAY ROOM CPT RB PT PT PT PT PT 3, 4
B-17 CORRIDOR RF RCB PT PT PT PETG/PT PT 1, 4, 5
B-18 MECH. ROOM RF RCB PETG PT PETG/PT PT PT 4, 5
1 2SCALE : 1/4" = 1’−0"
INTERIOR WINDOW TYPES3
REMARKS
1. WHERE INDICATED PETG/PT, PROVIDE PETG PANELS 4'-0" HIGH AFF.
2. PROVIDE PETG PANELS ON PARTIAL HEIGHT WALLS.
3. PROVIDE TRANSITION STRIP PER DETAIL 6/A-601. IF ALTERNATE NO. 1 IS ACCEPTED, PROVIDE PER DETAIL 7/A-601 WHERE APPLICABLE.
4. PAINTING OF CEILING INCLUDES PAINTING (EXISTING AND SCHEDULED) CONDUITS, PIPING, DUCTWORK, ETC.
5. PROVIDE RESINOUS FLOORING AND BASE.
SCALE : 1 1/2" = 1’−0"4
JAMB DETAIL A
N.T.S.SCALE :8
FLOOR TRANSITION DETAIL B
8 8
N.T.S.SCALE :7
FLOOR TRANSITION DETAIL A
REMARKS
1. EXISTING 3'-0" X 7'-0" STEEL DOOR (WITH VISION LITE) AND FRAME TO REMAIN. REMOVE EXISTING HARDWARE (RIM EXIT DEVICE, CLOSER, AND STRIKE PLATES) AND SALVAGE FOR RE-INSTALLATION. PAINT DOOR AND FRAME PAINT TYPE IAL-3 AND REINSTALL SALVAGED HARDWARE. DO NOT PAINT OVER EXISTING FIRE LABEL.
2. HARDWARE INCLUDES A MAGNETIC DOOR HOLD OPEN. WIRING AND CONNECTION TO THE FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR.
ETR
ETR
ETR
ETR
ETR
ETR
ETR
ETR
ETR
ETR
SCALE : 1 1/2" = 1’−0"6
JAMB DETAIL C
FINISH ABBREVIATIONS
CONC CONCRETECPT CARPET (TILE TYPE)ETR EXISTING TO REMAINPETG POLYETHYLENE TEREPHTHALATE PLASTIC PANELSPT PAINTRB RESILIENT BASERCB RESINOUS COVE BASERF RESINOUS FLOORING
NONE
SCALE : 1 1/2" = 1’−0"5
JAMB DETAIL B
GENERAL FINISH NOTES
1. PAINT EXPOSED FIRESTOPPING TO MATCH ADJACENT WALL COLOR.
2
2
2
07/24/2018 ADDENDUM 22
REVISED DRAWING 07/24/2018N.T.S.SCALE :
9RESINOUS COVE BASE DETAIL
2
![Page 30: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/30.jpg)
2
2
2
![Page 31: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/31.jpg)
2
2
2
![Page 32: DESIGN AND CONSTRUCTION GROUP THE GOVERNOR NELSON … 02_CHPE .pdf · updated 07/28/2015 printed 07/26/2018 page 1 of 5 project no. 45558-c, h, p, e design and construction group](https://reader033.vdocuments.site/reader033/viewer/2022042213/5eb82037e2902859776320ba/html5/thumbnails/32.jpg)
2
2