data sheet: tembreak 2 s1600-ne mccb - terasaki 1600... · door mounted (hs) / breaker mounted...

3
Frame reference Standard Optional - Not Available S1600 3, 4 NE 1600 690 - 800 8 45 3 65 85 100/85 125 - 34 50 65 75/65 94 - 65 125 20 - - B - - 370 210 280 140 27.0 35.0 I n U e U i U imp I cu I cs I cw height width depth weight Electrical Mechanical (A) (V) (V) (kV) (kA) (kA) (kA) (kA) (mm) (mm) (mm) (kg) cycles cycles 2,000 5,000 DATA SHEET: TEMBREAK 2 S1600-NE MCCB MCCB Electrical Characteristics to IEC 60947-2, EN 60947-2, JIS C 8201-2-1 ANN. 1, AS/NZS 3947-2, NEMA AB-1 Quantity Unit Condition TB2 1600 1600 50°C AC 50/60 Hz DC 690V AC 525V AC 440V AC 400/415V AC 220/240V AC 250V DC 690V AC 525V AC 440V AC 400/415V AC 220/240V AC 250V DC 480V AC 240V AC 0.3 Seconds 3 pole 4 pole 3 pole 4 pole 690V AC Max In (A) of Frame Model Number of Poles Type Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation voltage Rated impulse withstand voltage Ultimate breaking capacity (IEC, JIS, AS/NZS) Service breaking capacity (IEC, JIS, AS/NZS) Rated breaking capacity (NEMA) Rated short-time withstand current Protection Adjustable thermal, adjustable magnetic Fixed thermal, fixed magnetic Microprocessor Utilisation category Installation Front connection (FC) Extension bar (FB) Cable clamp (FW Rear connection (RC) Plug-in (PM) DIN rail mounting (DA) Dimensions Weight Operation Direct Opening Action Toggle operation Door mounted (HS) / Breaker mounted handle (HB) Motor operation (MC) Endurance MCCB cannot be used in IT systems at this voltage 100KA at 400V 75KA at 400V Page 1 of 3 2 1 3 3

Upload: others

Post on 31-Aug-2019

44 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DATA SHEET: TEMBREAK 2 S1600-NE MCCB - Terasaki 1600... · Door mounted (HS) / Breaker mounted handle (HB) Motor operation (MC) Endurance MCCB cannot be used in IT systems at this

Frame reference

Standard • Optional - Not Available

S16003, 4NE

1600

690-

800845 3

6585

100/85125

-345065

75/6594-6512520

-

-

B

••

--

37021028014027.035.0

In

Ue

U iU impIcu

Ics

Icw

heightwidth

depthweight

ElectricalMechanical

(A)

(V)

(V)(kV)(kA)

(kA)

(kA)

(kA)

(mm)(mm)

(mm)(kg)

cyclescycles

2,0005,000

DATA SHEET: TEMBREAK 2 S1600-NE MCCB MCCB Electrical Characteristics to IEC 60947-2, EN 60947-2, JIS C 8201-2-1 ANN. 1, AS/NZS 3947-2, NEMA AB-1

Quantity Unit Condition TB2 1600

1600

50°C

AC 50/60 HzDC

690V AC525V AC440V AC

400/415V AC220/240V AC

250V DC690V AC525V AC440V AC

400/415V AC220/240V AC

250V DC480V AC240V AC

0.3 Seconds

3 pole4 pole

3 pole4 pole

690V AC

Max In (A) of Frame

ModelNumber of PolesType

Nominal current ratings

Electrical characteristics

Rated operational voltage

Rated insulation voltageRated impulse withstand voltageUltimate breaking capacity(IEC, JIS, AS/NZS)

Service breaking capacity(IEC, JIS, AS/NZS)

Rated breaking capacity (NEMA)

Rated short-time withstand current

Protection

Adjustable thermal, adjustable magneticFixed thermal, fixed magnetic Microprocessor Utilisation category

Installation

Front connection (FC)Extension bar (FB)Cable clamp (FWRear connection (RC)Plug-in (PM)DIN rail mounting (DA)Dimensions

Weight

Operation

Direct Opening ActionToggle operationDoor mounted (HS) / Breaker mounted handle (HB)Motor operation (MC)

Endurance

MCCB cannot be used in IT systems at this voltage

100KA at 400V 75KA at 400V

Page 1 of 3

2

1

3

3

Page 2: DATA SHEET: TEMBREAK 2 S1600-NE MCCB - Terasaki 1600... · Door mounted (HS) / Breaker mounted handle (HB) Motor operation (MC) Endurance MCCB cannot be used in IT systems at this

DATA SHEET: TEMBREAK 2 S1600-NE MCCBOutline Dimensions S1600-NEASL: Arrangement Standard Line HL: Handle Frame Centre Line

Front connected

Rear connected

Front connected with Motor Operator

Rear connected with Motor Operator

Conductor overlap, max

Conductor overlap, max

Trip button (red)

Mounting angle

Mounting angle

( )ON side Center pole and Neutral poleOFF side All poles

Insulation tube

Panel cutout dimensions shown give an allowance of 1.5mm around the handle escutcheon.

Interpole barrier(removable)

Toggle extension(removable)

Toggle extension(removable)

Panel cutout (front view)

Drilling plan (front view)

Drilling plan (front view)

M8Mounting screw

M8Mounting screw

Mounting hole

Insulating plate

ø12

Mounting angleL4054055

Conductor overlap, max

Drilling plan (front view)

M8Mounting screw

Insulating plate

Control circuit terminal

Pad lock

Conductor overlap, max

Mounting angle

( )ON side Center pole and Neutral poleOFF side All poles

Insulation tube

Panel cutout (front view)Drilling plan (front view)

M8Mounting screw

Panel cutout dimensions shown give an allowance of 1.0mm around motor operator.

3P

ASL ASL

4PHL

HL

HL

HL

ASL

ASL

HL

4P3P

184

154

139(

min

)

70

4P3P

4P3P

85 3015 30

15

707070

ø9

ø13

139(

min

.)15

(max

)

184

154

110

9547

.5

200

170

15

100

370

100

140

70

78

190

78

190

105 17570707045

280210

ø9

3220

ASL

30

170

140

20

80 191

1828

140132

1120

46

17

LH

ASL

4P

R3

98

193

3P

ASL

6010

06530

13015115

851570

80 191

17 140

ø13

ø9

1525

154

184

30

4010

231

.5

117.

517

3.5

79

2032

15

100

100

370

170

200

28

70

4P

3P

11(max.) 4.5

262.5

18

358(max.)

20 46

1120

280

175105

707070

210

14045

166

4P3P

ASL ASL ASL ASL

R3

ø9

ø12

ASL

139(

min

.)15

184

154

153015

3085

130

262.

5

100

60

6530

13.5

90.5

11(max.) 4.5

262.5 70

4P

3P

70707015

4P

3P

168

4P

3P

HL

ASL

HL

HL

HL

HL HL

Page 2 of 3

Page 3: DATA SHEET: TEMBREAK 2 S1600-NE MCCB - Terasaki 1600... · Door mounted (HS) / Breaker mounted handle (HB) Motor operation (MC) Endurance MCCB cannot be used in IT systems at this

Note(1) Ii max. = 12 x In. (2) 1.0 x IR or 0.5 x IR can be selected. Characteristic of neutral protection (tN vs. IN) is identical to characteristic of phase protection (tR vs. IR). (3) When you specify gF on MCCBs with 3 poles the terminal block is automatically fitted to connect with the external neutral CT for 3 phases 4 wires system.

Percent Rated Current IRPercent Rated Current In

In = 1600A

LT

ST

PTA

NP

Option

Standard

IR (A)LTD Pick-up current IR xIn

1Characteristics No. 2 3 4 5 6 711

2.5 5 100.20.1

14(Max: 12 x In) Note (1)0.840

1.0/0.5 Note(2)

tN=tRtN

IN

tpIpIi

tsd

Isd xIR

xIRxIR

xIR

(s)

(s)

gFNote(3)

0.20.2tg

Ig xIn(s)

(s)

tR (s)at 200% x IR at 600% x IR

21 21 5 10 19 29

INST

0.4 0.5 0.63 0.8 0.9 0.95 1.0

Time/Current Characteristic Curves S1600-NE

Page 3 of 3

DATA SHEET: TEMBREAK 2 S1600-NE MCCB