I n U i U imp I cu I cs height width depth weight Electrical Mechanical 4 SDH - - 1,000 7,000 TB2 S250 50°C AC 50/60 Hz 1000V DC 750V DC 600V DC 500V DC 350V DC 1000V DC 750V DC 600V DC 500V DC 350V DC 3 pole 4 pole 3 pole 4 pole 1000V DC 750V DC 350 - 600V DC - 50 63 100 125 160 1000 8 5 - - - 166+55 x 2 - 140 68 - 1.9 Standard Optional - Not Available (A) (V) (kV) (kA) (kA) (mm) (mm) (mm) (kg) cycles cycles MCCB Electrical Characteristics to IEC 60947-2, EN 60947-2, JIS C 8201-2-1 ANN.1 Frame reference Quantity Unit C ondition 160 PVS160 Max In (A) of Frame Model Number of Poles Type Nominal current ratings Electrical characteristics Rated insulation voltage Rated impulse voltage Ultimate breaking capacity (IEC, JIS) Service breaking capacity (IEC, JIS) Protection Adjustable thermal, fixed magnetic Magnetic trip only (adjustable) Installation Front connection (FC) Extension bar (FB) Rear connection (RC) Plug-in (PM) DIN rail mounting (DA) Dimensions Weight Operation Direct Opening Action Toggle operation Breaker mounted (HB) Door mounted (HS) Motor operation Endurance DATA SHEET: TEMBREAK 2 PVS160-SDH MCCB FOR USE ABOVE 250V DC Page 1 of 3 Connect all poles in series when over DC250V The time constant (L/R) of the circuit should be less than 2.0ms nearby rated current less than 5ms for short circuit < 10kA less than 10ms for short circuit < 20kA less than 15ms for short circuit > 20kA Includes the dimensions of the terminal cover (Mandatory) 5 - - - -

Upload: vunhan

Post on 19-Aug-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DATA SHEET: TEMBREAK 2 PVS160-SDH MCCB … · I n U i U imp I cu I cs height width depth weight Electrical Mechanical 4 SDH • •--1,000 7,000 TB2 S250 50°C AC 50/60 Hz 1000V DC

In

U iU imp

Icu

Ics

heightwidth

depthweight

Electrical

Mechanical

4SDH

••

-

-

1,000

7,000

TB2 S250

50°C

AC 50/60 Hz

1000V DC750V DC600V DC500V DC350V DC

1000V DC750V DC600V DC500V DC350V DC

3 pole4 pole

3 pole4 pole

1000V DC750V DC

350 - 600V DC-

5063100125160

10008

5-

••--

166+55 x 2-

14068-1.9

Standard • Optional - Not Available

(A)

(V)(kV)

(kA)

(kA)

(mm)(mm)

(mm)(kg)

cycles

cycles

MCCB Electrical Characteristics to IEC 60947-2, EN 60947-2, JIS C 8201-2-1 ANN.1 Frame reference Quantity Unit C ondition

160PVS160

Max In (A ) of Frame

ModelNumber of PolesType

Nominal c urrent ratings

E lec tric al charac teris tic s

Rated insulation voltageRated impulse voltage

Ultimate breaking capacity(IEC, JIS)

Service breaking capacity(IEC, JIS)

P rotec tion

Adjustable thermal, fixed magneticMagnetic trip only (adjustable)

Ins tallation

Front connection (FC)Extension bar (FB)Rear connection (RC)Plug-in (PM)DIN rail mounting (DA)Dimensions

Weight

Operation

Direct Opening ActionToggle operationBreaker mounted (HB)Door mounted (HS)Motor operation

Endurance

DATA SHEET: TEMBREAK 2 PVS160-SDH MCCB FOR USE ABOVE 250V DC

Page 1 of 3

Connect all poles in series when over DC250VThe time constant (L/R) of the circuit should be less than 2.0ms nearby rated current less than 5ms for short circuit < 10kA less than 10ms for short circuit < 20kA less than 15ms for short circuit > 20kA Includes the dimensions of the terminal cover (Mandatory)

5----

Page 2: DATA SHEET: TEMBREAK 2 PVS160-SDH MCCB … · I n U i U imp I cu I cs height width depth weight Electrical Mechanical 4 SDH • •--1,000 7,000 TB2 S250 50°C AC 50/60 Hz 1000V DC

CL CL CL

LH

CL

LH

LH

CL

LH

LH

LH

CL

LH

CL

CL

23

5.4

4P 4P

4P

3535 35

4P 4P

ø24

35

144

126

3535

30.5

11.5

1916

5

35 3535

5555

5555

165

165

144

126

35

10535

140180

140180

180

ø11

22

4P

2.3

5.3

5.3

22

22

4P

52.5

48

14253.5

Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon.

Drilling plan (front view) Panel cutout (front view)

Preparation of conductor

Drilling plan (front view)

67.160.657.5

102

45

25.6

47.61.6t

96.669.610.561.6

29.64

13

9

102

144

206

ø9

6 16

69.661.6

70.496.6 105.4

67.160.257.1

1.6t

10.5

25 22

45

5.4

With extension bars ✽ (optional)

✽ Straight bars only. For line and load side, use with the terminal covers.

Front-connected

Rear-connected

Mounting hole

Terminal cover

Mounting hole

Conductoroverlap, max

M4✕0.7Tapped hole

M4✕0.7Mounting screw

Mounting hole Terminal cover

M4✕0.7Tapped hole

Insulating plate

Insulating plate

Insulating plateInsulating plate

M8 screw

Terminal cover

M4✕0.7Mounting screw

25(max.)max.t7

11(m

ax.)ø9

Insulating plate

Mounting plate(max. t3.2)

Insulating plate

Stud can be turned 45° or 90°

Conductor overlap, max

Terminal cover Insulating plate

Outline Dimensions: PVS160-SDH

ASL: Arrangement Standard Line HL: Handle Frame Centre Line

Page 2 of 3

DATA SHEET: TEMBREAK 2 PVS160-SDH MCCB FOR USE ABOVE 250V DC

Page 3: DATA SHEET: TEMBREAK 2 PVS160-SDH MCCB … · I n U i U imp I cu I cs height width depth weight Electrical Mechanical 4 SDH • •--1,000 7,000 TB2 S250 50°C AC 50/60 Hz 1000V DC

PVS160-SDH 4P

1 140 4030 3020 20

10 10

2 250-200A(Max) 250A(Max)

1 140 4030 3020 20

10 10

250A(Min)2 50-200A(Min) 2

1 10.6 0.60.4 0.4

0.2 0.2

0.1 0.10.06 0.060.04 0.04

0.02 0.02

0.01 0.01

0.005 0.005

Percent Rated Current Percent Rated Current

PVS 160-SDL, PVS 160-SDHRated current (A) Magnetic trip current (A) 14050 65063 819100 1300 130

125 1625160 2080 120

Notes : Setting tolerance ± 20%

110PVS 250-SDL, PVS 250-SDH 100A Rated current (A) Magnetic trip current (A) 63A 100 1300 100125 1625160 2080200 2600 90

250 2750 calibrated at 45 °C 5 25 35 45 55 60Notes : Setting tolerance ± 20%

Calibratedtemperature50A

200A,250A 125A,160A

15

Ambient temperature ( °C)

Trip

pin

g T

ime

seco

ndm

inut

eho

ur

100

125

200

300

400

500

700

1000

1500

2000

3000

4000

5000

8000

Trip

pin

g T

ime

seco

ndm

inut

eho

ur

Perc

ent c

urre

nt ra

ting

100

125

200

300

400

500

700

1000

1500

2000

3000

4000

5000

8000

32

64

64

32

64

64

Page 3 of 3

DATA SHEET: TEMBREAK 2 PVS160-SDH MCCB FOR USE ABOVE 250V DC