das amanda daom projekt – stand und zukünftige arbeiten · das amanda daom projekt – stand und...
TRANSCRIPT
29 January 2007 H. Leich, DESY Zeuthen 1
Z Seminar
Das AMANDA dAOM Projekt –Stand und zukünftige
Arbeiten
P. Desiati, V. Drozdov, H. Leich, T. Schmidt
29 January 2007 H. Leich, DESY Zeuthen 2
Z Seminar
Outline
• The Amanda Experiment
• Optical Module Concepts
• Main dAOM Functions
• dAOM Architecture
• dAOM Control System at the Surface
• Control Software
• User Interface
• Future Developments
29 January 2007 H. Leich, DESY Zeuthen 3
Z Seminar
The AMANDA detector in the ice at the Southpole
29 January 2007 H. Leich, DESY Zeuthen 4
Z Seminar
Optical Module Concepts
During the lifetime of AMANDA 3 different types of OMs have
been developed:
•• TheThe AnalogAnalog OpticalOptical Module: Module: AOMAOM
•• The Digitally controlledThe Digitally controlled AnalogAnalogOpticalOptical Module:Module: dAOMdAOM
•• TheThe DigitalDigital OpticalOptical Module: Module: DOMDOM
29 January 2007 H. Leich, DESY Zeuthen 5
Z Seminar
AMANDA: Analog Optical Modules
29 January 2007 H. Leich, DESY Zeuthen 6
Z Seminar
Optical Modules with new Technology
29 January 2007 H. Leich, DESY Zeuthen 7
Z Seminar
TOT Values for Electrical and Optical Signals at the Surface
29 January 2007 H. Leich, DESY Zeuthen 8
Z Seminar
Requirements for the dAOM design
• Reliability, high MTBF
• Cost efficiency
• Flexibility
• Easy to deploy and to exploit
• Low power consumption
29 January 2007 H. Leich, DESY Zeuthen 9
Z Seminar
Main dAOM Functions
• PMT power supply
–– High High voltagevoltage (HV)(HV) for thefor the PMT PMT is generated is generated usingusing aa special designedspecial designed DCDC--toto--HV HV converterconverter
• Communication with the DAQ system at the surface
• Analog pulse transmission via optical fiber and electrical copper cable
• Slow control functions:
-- Setting the HV for the PMTSetting the HV for the PMT
-- Setting the gain for the analog signal Setting the gain for the analog signal transmission to the surface transmission to the surface
-- Setting the bias current for the laser diode in Setting the bias current for the laser diode in the optical signal transmission paththe optical signal transmission path
• Monitoring:
-- the Temperature inside thethe Temperature inside the dAOMdAOM
-- Actual HV level (anode and last dynode) and Actual HV level (anode and last dynode) and status (on/off)status (on/off)
-- Supply voltage levels (+5V)Supply voltage levels (+5V)
29 January 2007 H. Leich, DESY Zeuthen 10
Z Seminar
dAOM Architecture
29 January 2007 H. Leich, DESY Zeuthen 11
Z Seminar
dAOM - Surface Communication
TransformerDriver
LineReceiverMicro
Controller
TxD
RxD
ManchesterCoder/
Decoder
TelecomTransformer
TxDm
RxDm
AMANDAcable
• The implemented solution for communication uses the following protocols:
–– Physical layerPhysical layer::•• Manchester codedManchester coded digitaldigital signal transfer based onsignal transfer based on
aa carrier ofcarrier of 320 kHz320 kHz
–– Data link layerData link layer::•• self definedself defined ASCIIASCII based frame structure protocolbased frame structure protocol
–– NetworkNetwork layerlayer::•• half duplexhalf duplex data transfer withdata transfer with aa clear defined clear defined
mastermaster--slave relationshipslave relationship
29 January 2007 H. Leich, DESY Zeuthen 12
Z Seminar
Remote Power Supply & HV
DC/DCConverter
DC PowerSource60 Vdc
PowerOn/off
Surface StationdAOM
2,5 km cable
Telecomtransformer
Telecomtransformer
Specifications for the HV-base (ISEG GmbH) :• Total HV: 0 ... 2100 VDC • HV 1. dynode: 250 ... 800 VDC• HV anode: 600 ... 1300 VDC• Stability: < 1*10-4
• Temperature coefficient: Tk < 5 * 10-5
• Ripple: < 10 mV• Power consumption: < 140 mW• Control voltage, HV 1. dynode: 0.25 ... 0.8 VDC• Control voltage, HV anode: 0.6 ... 1.3 VDC• Monitor voltage, HV 1. dynode: 0.25 ... 0.8 VDC• Monitor voltage, HV anode: 0.6 ... 1.3 VDC• Digital control: HV on/off• Digital monitor: HV error• Operating/storage temperature: -40 ... + 85 Celsius• Cathode is at GND, Anode at +HV
29 January 2007 H. Leich, DESY Zeuthen 13
Z Seminar
The dAOM Surface DAQ System
29 January 2007 H. Leich, DESY Zeuthen 14
Z Seminar
dAOM Command Format
Data is transmitted in form of frames. The command frames for the dAOM have the format:
Command ID( character &space )
Parameters Description
C S D1:A Setup PMT High Voltage Dynode1:AnodeC
H On/offHigh Voltage ON = 1/0
C E G:LD Analog transmitter gain G = 0..4095LED dc bias DAC LD = 0..4095
C V - Request dAOM settings & Switch on digitalmode
C C - Switch on analog transmission modeC T hh:mm:ss Time SetupC D MM/DD/YYYY Date Setup
Preamble C Command ID Parameters CR LF
C8 K Threshold Power supply current monitoringThreshold = 0..4095
C8 Q - Request dAOM_DAQ board status
C8 H N:on Channel N = 0..7 Power switch ON = 1..0
Channel #
CN W one record from .hexfile
Write to RAM record in Intel Hex File Format
CN I - Reset Program in RAM
DAOM commands
DAQ board commands
Commands to download programs to DAQ boards and dAOMs
29 January 2007 H. Leich, DESY Zeuthen 15
Z Seminar
The Slow Control Program
29 January 2007 H. Leich, DESY Zeuthen 16
Z Seminar
Client Software
29 January 2007 H. Leich, DESY Zeuthen 17
Z Seminar
dAOM Monitoring
29 January 2007 H. Leich, DESY Zeuthen 18
Z Seminar
Slow Control User Interface
29 January 2007 H. Leich, DESY Zeuthen 19
Z Seminar
29 January 2007 H. Leich, DESY Zeuthen 20
Z Seminar
dAOM Design Improvements
• Decreased power consumption
–– New DC/DC New DC/DC Converter Converter
– New 16 Bit μC (Siemens C164)
• CAN Bus based digital communication
• Changes in the Mechanics of the ISEG Base
• piggy pack Optical Transmitter Modul (OTM)
• ‘1 pe’ test pulser ?
• ...
29 January 2007 H. Leich, DESY Zeuthen 21
Z Seminar
dAOM DAQ System in CPCI Standard
29 January 2007 H. Leich, DESY Zeuthen 22
Z Seminar
29 January 2007 H. Leich, DESY Zeuthen 23
Z Seminar