daikin envi thermostat sales note -...

28
© 2012 Daikin AC Daikin ENVi Thermostat Sales Note 6/25/2013 Control Engineering Dept.

Upload: ngonhi

Post on 27-May-2019

214 views

Category:

Documents


0 download

TRANSCRIPT

© 2012 Daikin AC

Daikin ENVi ThermostatSales Note

6/25/2013Control Engineering Dept.

© 2012 Daikin ACSlide 2

Daikin ENVi Thermostat

The Daikin ENVi Intelligent Thermostat kit is the newest addition to Daikins residential controls offerings. The Daikin ENVi thermostat has an easy-to-read backlit color LCD screen that displays all the information you need to configure the thermostat. Use the navigation buttons on the right to quickly change the temperature, access features, and configure settings. Visit www.DaikinENVi.com for more information and access to the web portal.

Temperature Setting Ambient DisplayWeather ForecastWeekly Schedule

“Be ENVi’d”

DACA-TS1-1

© 2012 Daikin ACSlide 3

ENVi

intelligent. The ENVi has a built‐in 

live weather function and uses advanced algorithms so you can be sure your thermostat is always saving the most energy possible.  Automatic alerts and reminders notify you when your Daikin equipment is due for service, if there is an equipment malfunction or when it’s time to change your filter, so you don’t have to worry about it.

Easy. The Daikin ENVi is Wi‐Fi 

enabled, so you can make adjustments to your thermostat away from home on your tablet, computer, iPhone or Smart Phone. The ENVi has an easy to read high‐resolution color display, ergonomic buttons, and user friendly interface that makes it easy to setup your a personalized program, adjust your settings and create new vacation events whenever and where ever you need to.

Nature. Did you know that 

using your ENVi thermostat’s weekly schedule can provide energy‐savings for you?  It is one of the easiest ways to reduce your energy consumption and save you money on your utility bills?

Value. When you get an 

Daikin ENVi thermostat, we'll provide you with access to your own personal and secure web page to manage all aspects of your ENVi thermostat. It doesn't matter where you are — all you need is an Internet connection. And if you like that, there's also no annual fee which your sure to love!

© 2012 Daikin ACSlide 4

Daikin ENVi Thermostat Kit Model #: DACA‐TS1‐1

Sales order start in May 2013 Shipping in July 2013

1 year limited warranty Replace as a kit when necessary (No parts available) 

Need to be installed by a licensed professional

Support route 1st tier support – End User ‐‐> Dealer 2nd tier support – Dealer ‐‐> DACA Sales/Technical Support (Controls Engineering as 

back‐up) 3rd tier support – DACA Sales/Technical Support (Controls Engineering as back‐up) ‐‐> 

ecobee Technical Support

Highlights

© 2012 Daikin ACSlide 5

Applicable to an indoor unit which BRC944 can be used Single‐Split system Quaternity technically ok but no Dehumidification function available

Multi‐Split system  (2 ‐ 8 port) FFQ indoor unit is excluded 

SkyAir FTXS Indoor Units

Applicable indoor unit models: FTXS FTXN (09/12 requires KRP980B1 interface adapter) CTXS FDXS CDXS

Applicable Daikin System

© 2012 Daikin ACSlide 6

One box for a kit

Package dimensions   8.86in(W) x 8.46in(L) x 2.72in(H) (225mm x 215mm x 69mm)

Package weight 1.8 lb (825 g) Designed in USA/Canada Made in China

Package

© 2012 Daikin ACSlide 7

Specification

Fire retardant ABS plastic (CYCOLOY Resin C6200)UL 873 certified through Global EMC Labs

FCC ID: XF6-RS91-10N1102 IC: 8407A-91101102

Power Cable length 5’ 4”

© 2012 Daikin ACSlide 8

Comparison ChartFeatures ENVi BRC944 ARC452

Backlit Date / Time (D/T) D/T T TOn/Off Mode (C/H/A/D/F) C/H/A C/H/A/D/F C/H/A/D/FSetpoint (Dual/Single) D/S S SRoom Temperature sensor Room Humidity sensor Fan Speed 3 5 5Fan On/ Auto (w/ min run time)

Louver (Position/Swing) P/S P/S P/SWeekly Schedule Optimized Start Setback Control Hold Vacation On/Off Timer Intelligent Eye (enable/disable) Quick Save Utility Critical Peak Pricing Error Code (w/Plain Text)

Wi-Fi Enabled

Aux Heater Control

Outdoor Temperature Displayed Outdoor Humidity Displayed Weather Forecast Home Leave Night Set Mode Powerful Button

© 2012 Daikin ACSlide 9

The Daikin ENVi equipped the thermostat functions such as: Wall mount controller Backlit Single setpoints in Cool, Heat,  and Dual setpoints in Auto Fan On/Auto (Fan stops when room temp is satisfied) Min Fan On Time is configured for better air circulation Weekly Setback Schedule with  Hold, Vacation, Optimum Start (Smart Recovery)

High / Low temp alert and Equip maintenance reminder / e‐mail Wi‐Fi for web (PC) / mobile phone / tablet access and  Weather forecast and Outdoor temp

Temperature / Humidity sensing and display Utility CPP (Critical Peak Pricing) Setting available Daikin Error code and plain text (same text as 

Dr. Daikin mobile access) are displayed and e‐mailed.

Operation Benefits

© 2012 Daikin ACSlide 10

The ENVi Wi‐Fi capabilities will provide customer with the ability to monitor and control their Daikin system from where ever they are using their PC, smartphone, and tablet (internet connection necessary).   The ENVi has the latest Wi‐Fi encryption technologies to ensure that data is protected both in transmission and network access.

Remote Access

© 2012 Daikin ACSlide 11

Web Portal / mobile App

PC

Blackberry

iPad

Android

iPhone

© 2012 Daikin ACSlide 12

The ENVi provides Dealers with a Contractor Portal   This is an online tool that makes it even easier for Dealers to deepen their relationship with their customers, increase the overall Daikin system efficiency, and grow their business!

Contractor Portal

Equipment Details Maintenance / Service Reminders

HVAC Reports Alerts

© 2012 Daikin ACSlide 13

The Contractor Portal offers the dealer a variety of ways to maintain their relationship with their customers such as: Uploading their business information and logo so that it appears on your customers’ alerts and reminders. Sending branded Service Reminders to their customers based upon their preferred service schedule. View the make and model of their customers’ Daikin HVAC equipment right from their portal. Access their customers’ HVAC Reports for remote troubleshooting and diagnostics. Communicate specials and promotions to their customers and increase their web traffic by adding the Daikin ENVi login portal to their company’s webpage. 

Contractor Portal (cont’d)

© 2012 Daikin ACSlide 14

The Daikin ENVi thermostat supports a single‐stage auxiliary heater.  One relay implemented for an auxiliary heater

HEAT PUMP + AUX HEATER The Aux Heater operates as a second stage heater with the heat pump 

when heat pump cannot maintain room temperature (IF YOU ALLOW IT).  The ENVi determines aux heat use by monitoring  the temperature 

difference between setpoint and room temperature along with the time duration.  

The Aux Heater works as a backup heater without the heat pump when outdoor temp is low (MIN OA TEMP to run heat pump is configurable, disabled as default) or AUX HEAT ONLY is selected.

COOLING ONLY + (AUX) HEATER Heater works as a primary heat source.  Auto mode is available. 

Auxiliary Heater

© 2012 Daikin ACSlide 15

Call for Cooling RT > C_SP + 0.5F (configurable) Stop calling RT = C_SP

Call for Heating RT < H_SP ‐ 0.5F (configurable) Stop calling RT = H_SP

Auto Mode Change to Cool RT > C_SP + 0.5F Change to Heat RT < H_SP – 0.5F Min. setpoint differential  5F (configurable)

Sequence of Operation

© 2012 Daikin ACSlide 16

Fan operation Fan Auto – ENVi turn off the unit when the temperature satisfied Minimum Fan On Time makes Fan run for better air circulation while Fan Auto

Fan ON – ENVi changes to Fan mode when there is no call for cooling or heating The Fan will continue to run even when the system mode is set to Off.

Sequence of Operation (cont’d)

© 2012 Daikin ACSlide 17

Wiring Schematic

2 3 G

RedBlackGreen

TERMINAL BLOCK

DPCA

P2

P1

S21

MAIN PCB

Daikin Indoor Unit

Incoming 208/230V 1

Field Supplied 4 core thermostat wire

18AWG: 1,250ft / 380m20AWG: 800ft / 240m22AWG: 500ft / 150m

Wire Harness (5’ 4”)come within a box

Power Cable (5’ 4”)from DPCA

208/230VAC

DPCA can be installed in the backside cavity of the wall-mounted indoor unit (if space allows) and beside the ducted indoor unit. DPCA should not be installed in plenum.

Wires to outdoor unit not shown

To ENVi : 2-wires for power supply 24VAC2-wires for communication

ENVi Thermostat

© 2012 Daikin ACSlide 18

DPCA and ENVi wiring

D-, D+ : 2 wire for RS485 serial communication (Modbus)

C, R : 2 wire for power supply (24VAC)

© 2012 Daikin ACSlide 19

The DPCA 208/230VAC power is supplied by Indoor Unit DPCA has a step down transformer The ENVi thermostat’s 24VAC power is supplied by DPCA

ENVi and indoor unit communicate with Daikin RA Wired Remote Controller protocol Indoor unit to ENVi Unit type, Room Temp, Error code ENVi to Indoor unit On/Off, Operation Mode (Cool/Heat/Fan), Setpoint, Fan Speed, Louver Oscillate/Stop

Mechanism

© 2012 Daikin ACSlide 20

Sales support documents are available on TRL FTP site Sales Bulletin  Sales Preso (This)

Installation Manual [IM‐TS1‐1‐1305] User Manual [OM‐TS1‐1‐1305]

Installation Guide (by 5/E/2013) Quick User Guide (by 5/E/2013)

Supporting Documentation

© 2012 Daikin ACSlide 21

Training Training Class will cover ENVi starting Jun 2013. Visit www.daikinuniversity.com RLC Product and Application (Sales training) RLC Install and Commissioning (Commission training)

© 2012 Daikin ACSlide 22

ENVi has full thermostat usability/functionality, H+M doesn’t. 

Competitive Edge

Daikin ENVi H+M

Applicable model All models BRC944 is applicable (Backward compatible)

Specific models (Relatively new models only)

Installation DPCA wires to Indoor PCB and power terminals. Can be hidden in the indoor unitENVi wires to DPCA. No battery needed.

Red Link receiver wires to Indoor unit. Receiver cannot be hidden.Wireless thermostat battery powered.

WiFi Standardized Honeywell Internet Gateway (Option) needed.

LCD Full dot Color Segmented Monochrome

Thermostat Room Temp X X

Cool Operation Call for Cooling by ENViFan On/Auto available

Thermo on/off by IndoorFan always runs (even in setback)

Heat Operation Call for Heating by ENViFan On/Auto available

Thermo on/off by IndoorFan Ultra Low speed in thermo-off

Indoor Air Circulation Min Fan On Time is available N/A

Fan Speed, Louver control X X

Auto Changeover with Dual SP X X

Weekly Schedule X X

AUX Heater X N/A

Price $420 list Similar price range when WiFi capability added

© 2012 Daikin ACSlide 23

Can the ecobee thermostat sold in the market be connected to Daikin system? No – only the Daikin ENVi thermostat can be connected

Can the ENVi thermostat be used for No‐Daikin unit? No – Only the Daikin applicable indoor units only.

Can the ENVi control two, three or four indoor units in Multi‐Split system No – One for each indoor unit. You can create group control through the 

Web access.  What DPCA stands for? Daikin Power and Communication Adapter

Works with Heat Pump and Cooling Only? Yes, both. Available operation modes automatically configured

Fan Speed, Louver can be controlled? Yes by Fan menu on Thermostat (Not from Web / Mobile App)

Dry mode is available No

FAQ

© 2012 Daikin ACSlide 24

Wireless Remote can be used for operation? No. The ENVi will override it

KRP980B is needed? Yes, if it is needed for BRC944 (FTXN 09/12)

Auxiliary Heater can be controlled? Yes – for a single stage heater

FAQ (continued)

© 2012 Daikin ACSlide 25

Some models of the Indoor Unit include an intelligent eye, an infrared sensor that detects room occupancy. It adjust the set point by 3.6°F (2°C) if no movement is detected in order to save energy (+3.6°F/+2°C if cooling, ‐3.6°F/‐2°C if heating). 

To use intelligent eye, you must enable this option in the Daikin ENVithermostat and then enable it with the Daikin wireless remote controller. If enabled, the thermostat’s Smart Recovery (Optimum Start) and Temp Alert functions are not available. 

By default, intelligent eye is disabled on the thermostat.  Do NOT enable the intelligent eye with the Daikin wireless remote controller 

when it is disabled on the thermostat as this may cause suboptimal operation and result in invalid recovery and alert messages. Also, if an auxiliary heater is configured, enabling intelligent eye may energize the auxiliary heater more often than would normally be required.

Intelligent Eye

© 2012 Daikin ACSlide 26

In Multi‐Split system, the first unit which calls for cooling or heating determines the system operation mode.  Following units cannot change the system operation mode unless it is configured as the priority indoor unit.  While following units wait for the system operation mode change, indoor unit On Status Led is slowly blinking (2.5 sec on, 0.5 sec off)

At the ENVi, when the first unit stops calling, there will be a chance for following units to become the first unit and change the system operation mode. When system is in cooling mode, call for cooling and Fan On work. When system is in heating mode, only call for heating works. 

Mode Conflict in Multi‐Split

© 2012 Daikin ACSlide 27

Receiver for the wireless remote should be installed. Otherwise C9 error occurs. Room temp sensor in the receiver is used for indoor unit control.  It can be hidden above the ceiling. In this case, it should be located close to the return air to sense the room temperature. 

No louver menu on FDXS09/12LVJU which is the current model.  Louver menu is shown on the FDXS09/12DVJU, but it has no meaning.

Ducted Indoor unit

© 2012 Daikin AC

Thank You