d-alu suspension for ke-½d interior system qa-0003-gb-02 · cv cw cy da v i n k e l v i n k e l v...
TRANSCRIPT
D-alu skinne
½D-alu endestykke
Startskinne type 200mmStartskinne type 500mm
Klap profil:500 mm indsættes i skinnen inden endeprofilen monteres.Std. 500mm tilpasses på skinnen.
Spor til posevulst
Spor til samlestifterog endeskruer
Spor til loftsmontage(selvskærende skruer)
Spor til samlestifter og endeskruer
Montageåbning til tekstilvulst
Spor til klap profil
Samling ½D-Alu skinnerMonter systemet i henhold tiltegningerne og monteringsvejledning.
QA-0003-DK-00
D-Alu Suspension for KE-½D Interior SystemQA-0003-GB-02
½D-Alu Rail System
Install rail system according to drawings and enclosed mounting instructions.
Start rail type 200 mmStart rail type 500 mm
D-Alu rail
Channel for joining pinsand end screws
Channel for textile bulb
Channel for joining pins and end screws
Groove for guidance of mounting screws for ceiling (self-tappers)
½D-Alu rail
Channel opening for mounting of textile bulb
Channel for locking profile
Locking profile (std. 500 mm): Feed into D-Alu rails prior to mounting of end sections. Adjust length of locking profile to D-Alu rail.
Final locking profile is sawn off at approx. 10 mm short of D-Alu rail so as to prevent blocking.
28H
010.3
010.2
010.1
LS+20mm
LS
O
020.3
020.2
020.1
010.1
Ø
010.1
020.1
020.2
020.3
H
W
LS+20mm
LS
O
B
L = Pose længdeLS = Længde StudsØ = Studs DiameterH = HøjdeW = BreddeO = ForsætningA = Afstand studs 1B = Afstand studs 2
QA-0004-DK-00
L = Duct lengthLS = Length socketØ = Socket diameterH = HeightW = WidthO = OffsetA = Distance socket 1B = Distance socket 2
D-Alu for KE-½D Interior System (Inlet Options)QA-0004-GB-02
C D
E
F G
DC
E
X X
G
F
F
G
28mm
98mm
W - 28mm
H +
4mm
H -
28mm
W + 4mm
Hvis montering af studs er mulig over loft behøves der ingen lynlås i nærheden af studs.
Hvis montage af studs skal ske indvendigt skal man være opmærksom på at placere mindst 1 lynlås tæt på studsen. Eller der skal laves en service Lynlås i buen.
Indvendigt hjørne skal fastgøres med minimum en skrue i enten væg eller loft.
Når 1 vulst er monteret på skinnen,Husk at montere studsen før posen bliver sat fast.
Før snoren igennem hullet. Træk posen ud til enden af skinnen spænd Pinol med 3mm Umbracho ikke incl.
QA-0005-DK-00
Fasten inner corner of rail to wallor ceiling with at least one screw.
Feed cord through hole. Pull/push the duct along the rails until reaching the end section. Tighten the grub screw with a 3 mm Allen key (not included).
If it is possible to mount the socket above the ceiling, a zipper near the socket is unnecessary.
If mounting of the socket must be done from the inside you must place at least 1 zipper close to the socket. Otherwise a service zipper must be placed in the arch.
Remember to mount socket after finishing first bulb in rail.
D-Alu for KE-½D Interior System (Rail Assembly)QA-0005-GB-02
321
3
2
1
QA-0006-DK-00D-Alu for KE-½D Interior System (Mounting of Duct)QA-0006-GB-02
CJCJ
010.1010.2
010.3020.1
020.1
030.3040.1 050.1 060.1 070.1
070.2
030.2
030.1
A
A
Vink
el°
L
Ø
ØL
W
W
Ingen montage stifter ved knæk.Sidste skinne før og efter knæk monteres med min. 2 skruer
L = Pose længdeLS = Længde StudsØ = Studs DiameterH = HøjdeW = BreddeO = ForsætningA = Afstand studs 1B = Afstand studs 2
QA-0007-DK-00
L = Duct lengthLS = Length socketØ = Socket diameterH = HeightW = WidthO = OffsetA = Distance socket 1B = Distance socket 2
Angl
e°
No joining pins for elbows. The rail section immediately before and after the elbow must be fixed to the ceiling with min. 2 screws.
D-Alu Suspension for KE-½D Interior System (Plenum)QA-0007-GB-02
CT
CU
CV
CW
CY
DA
Vink
el°
Vink
el°
Vinkel°
50mm
50mm
50mm
50mm
50mm
50mm
QA-0008-DK-00
Up
Up
Angle°
Angl
e°An
gle°
D-Alu Suspension for KE-½D Interior System (Elbow)QA-0008-GB-02
See delivery note for specific angle
ElbowRight/Left
Elbow Downwards
Elbow Upwards
CK
CL
CM
CN
CP
CR
50mm
50mm
50mm
50mm
50mm
50mm
QA-0009-DK-00
Up
Up
D-Alu for KE-½D Interior System (Elbow 90°)QA-0009-GB-02
ElbowRight/Left
Elbow Downwards
Elbow Upwards