ctc 450 review 1 ww characteristics. objectives 2 understand the basics of storm drainage systems ...

24
CTC 450 Review 1 WW Characteristics

Upload: roxanne-simmons

Post on 28-Dec-2015

218 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

CTC 450 Review1

WW Characteristics

Page 2: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Objectives2

Understand the basics of storm drainage systems

Understand the basics of sewer systems

Page 3: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Storm Sewer System3

Surface waters enter system through inlets

Water is then conveyed through pipes and manholes

Quantity of runoff is determined using the rational method (Q=CIA)

Velocities designed for 3-10 fps

Page 4: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Sanitary Sewer System4

Laterals collect wastewaters to branch lines which are conveyed to large mains (also called trunks or outfall sewer)

Force main has WW conveyed under pressure via pumps

Sanitary sewers are placed deep enough to prevent freezing

Page 5: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Differences between Storm/Sewer Storm systems are designed to overflow

periodically (frequency)

Sewer systems are designed to contain all the wastewater; if surcharging occurs it’s usually a result of infiltration of stormwater

Stormwater pipes are much bigger than sewer pipes

Page 6: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Example 10-16

What is the maximum population that can be served by an 8” sanitary sewer laid at minimum grade using a design flow of 400 gpcd & a flowing full velocity=2 ft/sec?

From Table 10-1 Q=310 gpm @ min. slope (full-flow)

310 gpm / 400 gpcd (and adjust for units) =1100 people (approx. 275 houses)

Page 7: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Example 10-1 (Continued)7

Compute the diameter of storm drain to serve the same population based on the following:

30 people/acre; C=0.4, 10-yr frequency w/ IDF curve on page 123, tc=20 min, vel=5 ft/sec

Area=37 acres Intensity=4.2” Q=62 cfs Assuming full-flow; Area=12.4 square ft Diameter=4 ft

Page 8: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Manholes8

Usually circular with an inside diameter of 4 feet

Placed at all changes in sewer grade, pipe size, or alignments changes (horiz. & vertical)

Also placed at all intersections, at the end of each line, and at distances not greater than 400 ft (<=15”) or 500 ft (>15”)

Page 9: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Other Decorative Manholes

http://damncoolpics.blogspot.com/2006/12/japanese-manhole-cover-art.html

Page 10: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Surcharged Manholes

http://www.youtube.com/watch?v=SBPd0WOW70o

http://www.youtube.com/watch?v=4BkFp5CL4q0 http://www.youtube.com/watch?v=xwar6VbgY-M&feature=

related

Page 11: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

11

Page 12: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Service Connections12

House service pipe is connected to the collecting sewer

Traps prevent backup of sewer gases into the building interior

Building vents prevent traps from being siphoned dry

Page 13: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Sewer Pipes and Jointing13

Vitrified clay, PVC, or precast concrete may be used

DIP (ductile iron pipe) is used for force mains

Page 14: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Clay Pipe (http://gladdingmcbean.paccoast.com)

14

Page 15: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

PVC Pipe (http://www.precastconcretesales.com)

15

Page 16: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Concrete Pipe (http://www.hynds.co.nz/ )

16

Page 17: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Ductile Iron Pipe (http://img.alibaba.com/photo/50364371/Ductile_Iron_Pipe.jpg)

17

Page 18: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Load on Buried Pipe

Loading on pipe must be considered

Common types of bedding are shown on page 345

18

Page 19: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Pipe Joints http://www.nationalpipe.com/joint_assembly.php

19

Page 20: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Joints www.hancor.com/

product/sanitite.html 20

Page 21: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Sewer Testing21

Monitor infiltration (before connections) Only works if pipe is below water line

Monitor exfiltration Used if pipe above water line

Air testing

Page 22: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

Lift (Pump) Stations22

Pumping stations used when gravity flow not feasible

Avoid if possible because a nonfunctional lift station means that sewage water can back up into houses/businesses

Pumps can be installed in the wet well or kept separate from the wet well

Page 23: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

23

http://www.sanicon.net/titles/t8f9.gif

Page 24: CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems

24 www.extension.umn.edu