1 2 3 4 5 6 7 1 2 3 4 5 6 7 0 5 10 15 20 25 30 0 10 20 30 40 50 60 70 80 90 100 CrossLab Agilent Purchasing supplies for your Perkin Elmer GC systems is easy with Agilent CrossLab Liner O-rings Description Unit Similar to Manufacturer Part No. Agilent CrossLab Part No. Non-stick fluoroelastomer O-ring 10/pk N9302783 8010-0401 Non-stick fluoroelastomer O-ring, PSS Injector 10/pk N6101747 8003-0202 Silicone O-ring 10/pk N6101374 8003-0203 Graphite O-ring, PSS Injector 10/pk N6101751 8003-0204 Graphite O-ring 10/pk N6101378 8003-0205 Column Nuts Description Unit Similar to Manufacturer Part No. Agilent CrossLab Part No. Column nut, 1/16 in. 2/pk 09903392 8003-0311 Autosampler Syringes for PerkinElmer GC Systems, 1/pk Model Volume (µL) Description Needle Gauge/ Length (mm)/Tip Similar to Mfr. Syringe Part No. Agilent CrossLab Syringe Part No. Similar to Mfr. Replacement Needle and Plunger Repair Kit Part No. Agilent CrossLab Replacement Needle and Plunger Repair Kit Part No. AutoSystem, Autosystem XL, Clarus 0.5 Removable needle 23/70/cone tip N6101252 8003-0005 N6101469 8003-0006 Removable needle 26/70/bevelled cone tip 8003-0007 8003-0008 5 Fixed needle 23/70/cone tip N6101251 8003-0001 Fixed needle, gas tight 23/70/cone tip N6101390 8003-0002 Fixed needle 26/70/cone tip N6101380 8003-0003 50 Fixed needle 23/70/cone tip N6101760 8003-0004 Non-Stick Bleed and Temperature Optimized (BTO) Septa Description Similar to Manufacturer Part No. Agilent CrossLab Part No. 50/pk Agilent CrossLab Part No. 100/pk 11 mm, CenterGuide N9302972 8010-0223 8010-0224 Non-Stick Advanced Green Septa 11 mm, CenterGuide N6621028 N9306219 8010-0207 8010-0208 Non-Stick Long-Life Septa 11 mm, CenterGuide 8010-0239 8010-0240 General Purpose Septa 11 mm 54019985 8010-0255 8010-0256 Advantage Liner type: Splitless single taper liners with wool High level of deactivation/inertness ü Better peak shapes for active compounds at trace levels ü Lower detection limits ü More accurate quantification Minimal compound loss and degradation ü More accurate quantification ü Lower detection limits ü More reliable results, and less preventive maintenance Effective deactivation coverage for wool-packed liners ü Ability to use wool – even with highly active compounds ü Reduced compound discrimination and column contamination ü Better column protection, and less preventive maintenance Lot tested with demanding test probes ü Reproducible deactivation coverage ü Reliably inert flow path for active compounds at trace levels ü More accurate quantification Touchless packaging ü Easy installation without touching the liner ü Less troubleshooting due to contamination ü Ensures proper installation for longer instrument uptime A large, diverse portfolio of essential GC supplies Packaged for easy access and improved productivity Backed by our risk-free 90-day guarantee To learn more about the full Agilent CrossLab GC supplies portfolio, visit www.agilent.com/chem/CrossLab Agilent Ultra Inert deactivation with wool contributes to higher response and better peak shape for very active forensic basic drug compounds than a liner with active sites. Endrin: 100 ppb Liner type: Splitless single taper liners with wool Detector: ECD Recalibration required Injection # Liner with active sites (n=4) Agilent Ultra Inert deactivation (n=4) % Endrin Breakdown Agilent Ultra Inert deactivation with wool Higher response Better peak shape Peak identification: Liner with active sites with wool Oxycodone Temazepam Flunitrazepam Nitrazepam Clonazepam Alprazolam Certified performance: Every liner is packaged with a Certificate of Performance that you can peel and stick into your lab notebook for quick compliance reference. Easy traceability: The deactivation lot number is printed directly on the certificate; the liner lot number and part number are permanently etched on the liner glass. Visit www.agilent.com/chem/CrossLabUILiners • Keep gas lines clean and leak free • Protect your instrument and GC column with sensitive indicators • Stabilize quickly to enhance productivity and reduce helium gas consumption Minimize downtime on your non-Agilent HPLC instruments Agilent CrossLab Services: • Multi-vendor repair and maintenance • Compliance • Laboratory relocation services Liners for AutoSystem, AutoSystem XL, Clarus Systems Description ID (mm) OD (mm) Length (mm) Volume (µL) Unit Similar to Manufacturer Part No. Agilent Original Deactivation Similar to Manufacturer Part No. Agilent Ultra Inert Deactivation Split/Splitless Liners PSS straight 2.0 4.0 86.2 5/pk 8003-0103 N6502002 8003-0153 PSS straight with bottom restriction 2.0 4.0 86.2 260 5/pk N6121004 8003-0158 PSS on-column 2.0 4.0 86.2 250 5/pk N6101539 8003-0110 N6101539 8003-0165 PSS straight 1.0 4.0 86.2 65 5/pk N6121006 8003-0157 Split/Large Volume Splitless Liners Straight with bottom restriction 4.0 6.2 92.1 1150 5/pk N6121001 8003-0105 N6121001 8003-0159 Splitless Liners Straight 2.0 6.2 92.1 300 5/pk N6101372 8003-0107 N6101372 8003-0162 Split Liners Straight-through 4.0 6.2 92.1 1150 5/pk 8003-0101 8003-0151 Straight, wool 4.0 6.2 92.1 1100 5/pk N6121020 8003-0106 N6121020 8003-0160 Straight with bottom restriction 4.0 6.2 92.1 1100 5/pk N6101052 8003-0111 N6101052 8003-0166 Direct Liners Gooseneck, drilled hole on top, wool 4.0 6.2 92.1 5/pk N6121022 8003-0155 Other Liners Packed column, straight 3.0 6.2 112 800 5/pk N6121000 8003-0108 N6121000 8003-0163 Programmable on-column, hour glass 2.2 4.0 16 5/pk N6101703 8003-0109* PTV, 0.25 mm ID restriction, recessed gooseneck 1.0 2.0 88 70 5/pk 8003-0104 8003-0154 *P/N 8003-0109 is not deactivated Agilent CrossLab works with Capillary Column Ferrules Model Fitting Size (in.) Ferrule ID (mm) Column ID (mm) Hole Unit Similar to Manufacturer Part No. Agilent CrossLab Part No. 85% Vespel/15% Graphite Capillary Column Ferrules AutoSystem, Autosystem XL, Clarus 1/16 0.4 0.25 1 10/pk 09920104 8010-0310 1/16 0.4 0.25 2 10/pk 04972392 8010-0312 1/16 0.5 0.32 1 10/pk 09920105 8010-0311 1/16 0.5 0.32 2 10/pk N9306000 8003-0216 1/16 0.8 0.53 1 10/pk 09920107 8010-0313 Vespel Capillary Column Ferrules AutoSystem, Autosystem XL, Clarus 1/16 0.3 0.18 mm ID or smaller 1 10/pk 8010-0306 1/16 0.4 0.25 1 10/pk 8010-0307 1/16 0.5 0.32 1 10/pk 8010-0308 1/16 0.8 0.53 1 10/pk 8010-0309 Graphite Capillary Column Ferrules AutoSystem, Autosystem XL, Clarus 1/16 0.4 0.25 1 10/pk 8010-0301 1/16 0.5 0.32 1 10/pk 09903700 8010-0302 1/16 0.5 0.32 1 10/pk N9306001 8010-0303 1/16 0.8 0.53 1 10/pk 09920141 8010-0304 Packed Column Ferrules Model Fitting Size (in.) Ferrule ID (in.) Column OD (in.) Hole Unit Similar to Manufacturer Part No. Agilent CrossLab Part No. 85% Vespel/15% Graphite Packed Column Ferrules AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk 09903739 8010-0314 1/8 1/8 1/8 1 10/pk N9302081 8003-0219 1/16 1/16 1/16 1 10/pk 09920127 8010-0315 Vespel Packed Column Ferrules AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk N9301361 8003-0223 1/8 1/8 1/8 1 10/pk N9301360 8003-0222 1/16 1/16 1/16 1 10/pk 8003-0221 Graphite Packed Column Ferrules AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk 09920140 8010-0305 1/8 1/8 1/8 1 10/pk 09903915 8003-0212 1/16 1/16 1/16 1 10/pk 02450972 8003-0211 Bring the benefits of Ultra Inert liners to your whole lab Inlet liners are a critical link in your sample flow path; however, they can also be a source of activity and analyte loss. Agilent CrossLab Ultra Inert inlet liners solve these problems with a highly inert chemistry that maximizes sample transfer while minimizing analyte loss. After 101 injections, the Agilent Ultra Inert deactivation shows significantly less decomposition than competitive liner deactivations. Download your complete Agilent CrossLab Quick Reference Guide for PerkinElmer GC Systems by scanning this QR code. Liner Body Lot: A0023 Deactivation Lot: B39020 Certificate of Performance 8002-0157 Ultra Inert Liner PTV, Strt W/bot Restrict, 2 mm 5pk This information is subject to change without notice. © Agilent Technologies, Inc. 2012 Printed in USA July 11, 2012 5991-0430EN BRUKER/VARIAN CTC PERKINELMER SHIMADZU THERMO AND MORE Agilent CrossLab vials, closures, and septa stop unknown peaks from impacting your results Cleanliness and consistency for precision lab work Engineered with the same quality as Agilent instruments Flawless performance with former Varian autosamplers Wide selection: choose the right vial for your needs at www.agilent.com/chem/SelectVials The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the OEM counterparts. All Agilent CrossLab supplies are backed by Agilent's 90-day money-back warranty. Supplies for Perkin Elmer GC Systems From injection through instrument… count on Agilent for everything that touches your sample Put decades of Agilent innovation behind every separation Agilent J&W GC columns: • Largest portfolio of innovative GC columns, over 3700 • Best inertness, lowest bleed, tightest reproducibility • Quality ensured by most stringent testing in the industry Agilent Bond Elut SPE, Bond Elut QuEChERS and Captiva Filtration Sample Prep family of products offer the widest range of solutions for every level of sample cleanliness to help you increase throughput and increase the quality of your data Deliver the cleanest gas for your most reliable analysis Agilent Gas Clean filters: Proof that Agilent CrossLab Ultra Inert liners deliver superior deactivation performance Your first choice for reproducible sample prep Agilent Sample Prep products:

Upload: others

Post on 28-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cro Agilent ssLab · Liner O-rings Description Unit Similar to Manufacturer Part No. Agilent CrossLab Part No. Non-stick fluoroelastomer O-ring 10/pk N9302783 8010-0401 Non-stick

1 2

3 4

5 6

7

1

2

3 4

5 6

7

0

5

10

15

20

25

30

0 10 20 30 40 50 60 70 80 90 100

CrossLabAgilent

Purchasing supplies for your Perkin Elmer GC systems is easy with Agilent CrossLab

Liner O-rings

Description Unit

Similar toManufacturerPart No.

Agilent CrossLabPart No.

Non-stick fluoroelastomer O-ring 10/pk N9302783 8010-0401

Non-stick fluoroelastomer O-ring, PSS Injector 10/pk N6101747 8003-0202

Silicone O-ring 10/pk N6101374 8003-0203

Graphite O-ring, PSS Injector 10/pk N6101751 8003-0204

Graphite O-ring 10/pk N6101378 8003-0205

Column Nuts

Description Unit

Similar toManufacturerPart No.

Agilent CrossLabPart No.

Column nut, 1/16 in. 2/pk 09903392 8003-0311

Autosampler Syringes for PerkinElmer GC Systems, 1/pk

ModelVolume

(µL) DescriptionNeedle Gauge/Length (mm)/Tip

Similar to Mfr.Syringe Part No.

Agilent CrossLabSyringe Part No.

Similar to Mfr.Replacement Needleand Plunger Repair Kit Part No.

Agilent CrossLabReplacement Needleand Plunger Repair Kit Part No.

AutoSystem, Autosystem XL, Clarus 0.5 Removable needle 23/70/cone tip N6101252 8003-0005 N6101469 8003-0006

Removable needle 26/70/bevelled cone tip 8003-0007 8003-0008

5 Fixed needle 23/70/cone tip N6101251 8003-0001

Fixed needle, gas tight 23/70/cone tip N6101390 8003-0002

Fixed needle 26/70/cone tip N6101380 8003-0003

50 Fixed needle 23/70/cone tip N6101760 8003-0004

Non-Stick Bleed and Temperature Optimized (BTO) Septa

Description

Similar toManufacturerPart No.

Agilent CrossLabPart No. 50/pk

Agilent CrossLabPart No. 100/pk

11 mm, CenterGuide N9302972 8010-0223 8010-0224

Non-Stick Advanced Green Septa

11 mm, CenterGuide N6621028N9306219

8010-0207 8010-0208

Non-Stick Long-Life Septa

11 mm, CenterGuide 8010-0239 8010-0240

General Purpose Septa

11 mm 54019985 8010-0255 8010-0256

Advantage Liner type: Splitless single taper liners with woolHigh level ofdeactivation/inertness

ü Better peak shapes for active compounds at trace levels

ü Lower detection limits

üMore accurate quantification

Minimal compound lossand degradation

üMore accurate quantification

ü Lower detection limits

üMore reliable results, and less preventive maintenance

Effective deactivationcoverage for wool-packed liners

ü Ability to use wool – even with highly active compounds

ü Reduced compound discrimination and column contamination

ü Better column protection, and less preventive maintenance

Lot tested withdemanding test probes

ü Reproducible deactivation coverage

ü Reliably inert flow path for active compounds at trace levels

üMore accurate quantification

Touchless packaging ü Easy installation without touching the liner

ü Less troubleshooting due to contamination

ü Ensures proper installation for longer instrument uptime

• A large, diverse portfolio of essential GC supplies• Packaged for easy access and improved productivity• Backed by our risk-free 90-day guarantee

To learn more about the full Agilent CrossLab GC supplies portfolio, visit www.agilent.com/chem/CrossLab

Agilent Ultra Inert deactivation with wool contributes to higher responseand better peak shape for very active forensic basic drug compounds thana liner with active sites.

Endrin: 100 ppbLiner type: Splitless single taper liners with woolDetector: ECD

Recalibrationrequired

Injection #

Liner with active sites (n=4) Agilent Ultra Inert deactivation (n=4)

% E

ndrin

Bre

akdo

wn

Agilent Ultra Inert deactivation with wool

Higher response

Better peak shape

Peak identification:

Liner with active sites with wool

OxycodoneTemazepamFlunitrazepam

NitrazepamClonazepamAlprazolam

Certified performance: Every liner is packaged with aCertificate of Performance that you can peel and stickinto your lab notebook for quick compliance reference.

Easy traceability: The deactivation lot number is printeddirectly on the certificate; the liner lot number and partnumber are permanently etched on the liner glass.

Visit www.agilent.com/chem/CrossLabUILiners

• Keep gas lines clean and leak free• Protect your instrument and GCcolumn with sensitive indicators

• Stabilize quickly to enhanceproductivity and reduce helium gas consumption

Minimize downtime on your non-Agilent HPLC instruments

Agilent CrossLab Services:

• Multi-vendor repair and maintenance• Compliance• Laboratory relocation services

Liners for AutoSystem, AutoSystem XL, Clarus Systems

DescriptionID

(mm)OD

(mm)Length (mm)

Volume (µL) Unit

Similar toManufacturerPart No.

AgilentOriginalDeactivation

Similar toManufacturerPart No.

AgilentUltra InertDeactivation

Split/Splitless Liners

PSS straight 2.0 4.0 86.2 5/pk 8003-0103 N6502002 8003-0153

PSS straight with bottom restriction 2.0 4.0 86.2 260 5/pk N6121004 8003-0158

PSS on-column 2.0 4.0 86.2 250 5/pk N6101539 8003-0110 N6101539 8003-0165

PSS straight 1.0 4.0 86.2 65 5/pk N6121006 8003-0157

Split/Large Volume Splitless Liners

Straight with bottom restriction 4.0 6.2 92.1 1150 5/pk N6121001 8003-0105 N6121001 8003-0159

Splitless Liners

Straight 2.0 6.2 92.1 300 5/pk N6101372 8003-0107 N6101372 8003-0162

Split Liners

Straight-through 4.0 6.2 92.1 1150 5/pk 8003-0101 8003-0151

Straight, wool 4.0 6.2 92.1 1100 5/pk N6121020 8003-0106 N6121020 8003-0160

Straight with bottom restriction 4.0 6.2 92.1 1100 5/pk N6101052 8003-0111 N6101052 8003-0166

Direct Liners

Gooseneck, drilled hole on top, wool 4.0 6.2 92.1 5/pk N6121022 8003-0155

Other Liners

Packed column, straight 3.0 6.2 112 800 5/pk N6121000 8003-0108 N6121000 8003-0163

Programmable on-column, hour glass 2.2 4.0 16 5/pk N6101703 8003-0109*

PTV, 0.25 mm ID restriction, recessed gooseneck

1.0 2.0 88 70 5/pk 8003-0104 8003-0154

*P/N 8003-0109 is not deactivated

Agilent CrossLab works with

Capillary Column Ferrules

ModelFitting Size

(in.)Ferrule ID

(mm)Column ID

(mm) Hole Unit

Similar toManufacturerPart No.

Agilent CrossLabPart No.

85% Vespel/15% Graphite Capillary Column Ferrules

AutoSystem, Autosystem XL, Clarus 1/16 0.4 0.25 1 10/pk 09920104 8010-0310

1/16 0.4 0.25 2 10/pk 04972392 8010-0312

1/16 0.5 0.32 1 10/pk 09920105 8010-0311

1/16 0.5 0.32 2 10/pk N9306000 8003-0216

1/16 0.8 0.53 1 10/pk 09920107 8010-0313

Vespel Capillary Column Ferrules

AutoSystem, Autosystem XL, Clarus 1/16 0.3 0.18 mm ID or smaller 1 10/pk 8010-0306

1/16 0.4 0.25 1 10/pk 8010-0307

1/16 0.5 0.32 1 10/pk 8010-0308

1/16 0.8 0.53 1 10/pk 8010-0309

Graphite Capillary Column Ferrules

AutoSystem, Autosystem XL, Clarus 1/16 0.4 0.25 1 10/pk 8010-0301

1/16 0.5 0.32 1 10/pk 09903700 8010-0302

1/16 0.5 0.32 1 10/pk N9306001 8010-0303

1/16 0.8 0.53 1 10/pk 09920141 8010-0304

Packed Column Ferrules

ModelFitting Size

(in.)Ferrule ID

(in.)Column OD

(in.) Hole Unit

Similar toManufacturerPart No.

Agilent CrossLabPart No.

85% Vespel/15% Graphite Packed Column Ferrules

AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk 09903739 8010-0314

1/8 1/8 1/8 1 10/pk N9302081 8003-0219

1/16 1/16 1/16 1 10/pk 09920127 8010-0315

Vespel Packed Column Ferrules

AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk N9301361 8003-0223

1/8 1/8 1/8 1 10/pk N9301360 8003-0222

1/16 1/16 1/16 1 10/pk 8003-0221

Graphite Packed Column Ferrules

AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk 09920140 8010-0305

1/8 1/8 1/8 1 10/pk 09903915 8003-0212

1/16 1/16 1/16 1 10/pk 02450972 8003-0211

Bring the benefits of Ultra Inert liners to your whole labInlet liners are a critical link in your sample flow path; however, they can also be a source of activity and analyte loss. Agilent CrossLab Ultra Inert inlet liners solve these problems with a highly inert chemistrythat maximizes sample transfer while minimizing analyte loss.

After 101 injections, the Agilent Ultra Inert deactivation shows significantlyless decomposition than competitive liner deactivations.

Download your complete Agilent CrossLab Quick Reference Guidefor PerkinElmer GC Systems by scanning this QR code.

Liner Body Lot: A0023Deactivation Lot: B39020

Certificate of Performance

8002-0157 Ultra Inert LinerPTV, Strt W/bot Restrict, 2 mm 5pk

This information is subject to change without notice.

© Agilent Technologies, Inc. 2012Printed in USA July 11, 2012

5991-0430EN

BRUKER/VARIAN CTC PERKINELMER SHIMADZU THERMO AND MORE

Agilent CrossLab vials, closures, and septa stop unknown peaks from impacting your results• Cleanliness and consistency for precision lab work• Engineered with the same quality as Agilent instruments • Flawless performance with former Varian autosamplers• Wide selection: choose the right vial for your needs atwww.agilent.com/chem/SelectVials

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the CrossLab products are viablealternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products mayhave slightly different designs as compared to the OEM counterparts. All Agilent CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Supplies for Perkin Elmer GC Systems

From injection through instrument… count on Agilent for everything that touches your sample

Put decades of Agilent innovation behind every separation

Agilent J&W GC columns:

• Largest portfolio of innovativeGC columns, over 3700

• Best inertness, lowest bleed,tightest reproducibility

• Quality ensured by moststringent testing in the industry

Agilent Bond Elut SPE, Bond Elut QuEChERS and Captiva Filtration Sample Prep family of products offer the widestrange of solutions for every level of sample cleanliness to help you increase throughput and increase the quality of your data

Deliver the cleanest gas for your most reliable analysis

Agilent Gas Clean filters:

Proof that Agilent CrossLab Ultra Inert liners deliversuperior deactivation performance

Your first choice for reproducible sample prep

Agilent Sample Prep products: