Page 1084 Mar 2008 Siemens ITS CPU 319-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the CPU in encrypted form by means of S7-Block Privacy to protect the know-how of the application. Diagnostics buffer; the last 500 error and interrupt events are stored in a buffer for diagnostic purposes, of which 100 are stored retentively. Maintenance-free data backup; the CPU automatically saves all data (up to 700 KB) in case of power failure so that the data are available again unchanged when the power returns.

Upload: duonghanh

Post on 18-Mar-2018

226 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1084 Mar 2008 Siemens ITS

CPU 319-3 PN/DP

Function

Password protection;a password concept protects the user program from unauthorized access.

Block encryption;the functions (FCs) and function blocks (FBs) can be stored in the CPU in encrypted form by means of S7-BlockPrivacy to protect the know-how of the application.

Diagnostics buffer;the last 500 error and interrupt events are stored in a buffer for diagnostic purposes, of which 100 are storedretentively.

Maintenance-free data backup;the CPU automatically saves all data (up to 700 KB) in case of power failure so that the data are available againunchanged when the power returns.

Page 2: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1085 Mar 2008 Siemens ITS

Parameterizable propertiesThe S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7: General:

Definition of the name, plant designation and location designation. Startup;

definition of the startup characteristics of the CPU and the monitoring time Isochronous mode interrupts;

setting of the DP master system, sub-process image number and delay time Cycle/clock memory;

specification of the maximum cycle time and load. Setting of the clock memory address. Enabling prioritized HMIcommunication

Retentivity;setting retentive areas

Clock interrupts;setting the start date, start time and periodicity

Watchdog interrupts;setting of periodicity

System diagnostics;determining handling and scope of the diagnostic alarms

Clock;setting the type of synchronization in the AS or on the MPI

Protection level;specifying the access rights to program and data

Communication;reservation of connection resources

Web;

Page 3: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1086 Mar 2008 Siemens ITS

settings for the Web server of the CPU MPI/PROFIBUS DP interface;

setting the interface type. Determining node addresses. Parameterizing the operating mode and configuring thetransfer areas in the case of PROFIBUS DP. Parameterizing the time synchronization

PROFIBUS DP master/slave interfaces;user-defined address assignment for distributed I/O. Parameterizing the operating mode and configuring thetransfer areas in the case of PROFIBUS DP. Parameterizing the time synchronization

PROFINET interface;Setting the addresses. Parameterizing the PROFINET properties, the I-Device functionality, the type ofsynchronization on PROFINET, the time synchronization using NTP procedure, the media redundancy, and theKeepAlive function. Parameterizing port 1 and port 2

Display and information functions

Status and error indications;LEDs indicate hardware, programming, time, I/O and bus errors, and operating statuses such as RUN, STOP andstart-up. In addition, maintenance requirements are displayed

Test functions;the PG is used to indicate signal states during program execution, to modify process variables independently ofthe user program and to output the contents of stack memories.

Information functions;

Page 4: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1087 Mar 2008 Siemens ITS

the PG can be used to obtain information about the memory capacity and operating mode of the CPU, the currentloading of the work and load memory, current cycle times and diagnostics buffer content in plain text.

Integrated communication functions

PG/OP communication Global data communication S7 basic communication S7 communication S5-compatible communication Routing Data record routing PROFIBUS DP master/slave Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006) PROFINET IO controller PROFINET I-Device PROFINET CBA Web server

System functionsThe CPU provides many extensive system functions for diagnostics, parameterization, synchronization, alerting, timemeasurement, etc.For detailed information, refer to the manual.

Technical specifications

Page 5: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1088 Mar 2008 Siemens ITS

6ES7 318-3EL00-0AB0Product versionHardware product version 09Firmware version V2.8General informationassociated programming package STEP 7 V5.4 + SP5 or higher or STEP 7

V5.4 + SP4 or higher with HSP 186Supply voltage24 V DC YesInput currentCurrent consumption (rated value) 1 050 mACurrent consumption (in no-load operation),typ.

400 mA

Inrush current, typ. 4 AI²t 1.2 A²·sPower lossesPower loss, typ. 14 WMemoryWork memory•integrated 1 400 Kibyte•expandable No

Technical specifications

Page 6: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1089 Mar 2008 Siemens ITS

•Size of retentive memory for retentive datablocks

700 kbyte

Load memory•pluggable (MMC) Yes•pluggable (MMC), max. 8 Mbyte•Data management on MMC (after lastprogramming), min.

10 a

Backup•present Yes; Guaranteed by MMC (maintenance-

free)•without battery Yes; Program and dataCPU-blocksNumber of blocks (total) 4 096; (DBs, FCs, FBs); the maximum

number of loadable blocks can be reducedby the MMC used.

DB•Number, max. 4 096; Number range: 1 to 16000•Size, max. 64 KibyteFB•Number, max. 4 096; Number range: 0 to 7999•Size, max. 64 KibyteFC•Number, max. 4 096; Number range: 0 to 7999•Size, max. 64 Kibyte

Page 7: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1090 Mar 2008 Siemens ITS

OB•Size, max. 64 KibyteNesting depth•per priority class 16•additional within an error OB 4CPU processing timesfor bit operations, min. 0.01 µsfor word operations, min. 0.02 µsfor fixed point arithmetic, min. 0.02 µsfor floating point arithmetic, min. 0.04 µsCounters, timers and their retentivityS7 counter•Number 2 048•Retentivity

• adjustableYes

• lower limit0

• upper limit2 047

• presetZ 0 to Z 7

•Counting rangeYes

Page 8: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1091 Mar 2008 Siemens ITS

• adjustableYes

• lower limit0

• upper limit999

IEC counter•present Yes•Type SFB•Number Unlimited (limited only by RAM capacity)S7 times•Number 2 048•Retentivity

• adjustableYes

• lower limit0

• upper limit2 047

• presetNo retentivity

•Time range

• lower limit10 ms

Page 9: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1092 Mar 2008 Siemens ITS

• upper limit9 990 s

IEC timer•present Yes•Type SFB•Number Unlimited (limited only by RAM capacity)Data areas and their retentivityretentive data area, total All, max. 700 KBFlag•Number, max. 8 192 byte•Retentivity available Yes; MB 0 to MB 8191•Retentivity preset MB 0 to MB 15•Number of clock memories 8; 1 memory byteData blocks•Retentivity adjustable Yes; via non-retain property on DB•Retentivity preset YesLocal data•per priority class, max. 32 768 byte; Max. 2048 bytes per blockAddress areaI/O address area•Inputs 8 192 byte•Outputs 8 192 byte•of which, distributed

8 192 byte

Page 10: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1093 Mar 2008 Siemens ITS

• Inputs8 192 byte

• Outputs8 192 byte

Process image•Inputs, adjustable 8 192 byte•Outputs, adjustable 8 192 byte•Inputs, default 256 byte•Outputs, default 256 byteSubprocess images•Number of subprocess images, max. 1Digital channels•integrated channels (DI) 0•integrated channels (DO) 0•Inputs 65 536•Outputs 65 536•Inputs, of which central 1 024•Outputs, of which central 1 024Analog channels•Integrated channels (AI) 0•Integrated channels (AO) 0•Inputs 4 096•Outputs 4 096•Inputs, of which central 256

Page 11: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1094 Mar 2008 Siemens ITS

•Outputs, of which central 256Hardware configurationRacks, max. 4Modules per rack, max. 8Expansion devices, max. 3Number of DP masters•integrated 2•via CP 4Number of operable FMs and CPs(recommended)•FM 8•CP, point-to-point 8•CP, LAN 10Time of dayClock•Hardware clock (real-time clock) Yes•battery-backed and synchronizable Yes•Deviation per day, max. 10 s•Backup time 6 wk; At 40 °C ambient temperature•Behavior of the clock following expiry ofbackup period

Clock continues to run with the time atwhich the power failure occurred

Operating hours counter•Number 4•Number/Number range 0 to 3

Page 12: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1095 Mar 2008 Siemens ITS

•Range of values 0 to 2^31 hours (when using SFC 101)•Granularity 1 hour•retentive Yes; Must be restarted at each restartClock synchronization•supported Yes•to MPI, master Yes•to MPI, slave Yes•to DP, master Yes; With DP slave only slave clock•to DP, slave Yes•in AS, master Yes•in AS, slave Yes•on Ethernet via NTP Yes; as client1st interfaceType of interface Integrated RS 485 interfacePhysics RS 485Isolated YesPower supply to interface (15 to 30 VDC), max.

150 mA

Functionality•MPI Yes•DP master Yes•DP slave Yes•Point-to-point connection NoMPI

Page 13: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1096 Mar 2008 Siemens ITS

•Number of connections 32•Services

• PG/OP communicationYes

• RoutingYes

• Global data communicationYes

• S7 basic communicationYes

• S7 communicationYes

• S7 communication, as clientNo; but via CP and loadable FB

• S7 communication, as serverYes

•Transmission rate, max. 12 Mbit/sDP master•Services

• PG/OP communicationYes

• Global data communicationNo

Yes; I blocks only

Page 14: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1097 Mar 2008 Siemens ITS

• S7 basic communication

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes

• Equidistance mode supportYes

• Isochronous modeNo

• SYNC/FREEZEYes

• Activation/deactivation of DP slavesYes

• Number of DP slaves that can besimultaneously activated/deactivated,max.

8

• Direct data exchange (slave-to-slavecommunication)

Yes; As subscriber

• DPV1Yes

Page 15: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1098 Mar 2008 Siemens ITS

•Transmission rate, max. 12 Mbit/s•Number of DP slaves, max. 124•Address area

• Inputs, max.8 Kibyte

• Outputs, max.8 Kibyte

•User data per DP slave

• Inputs, max.244 byte

• Outputs, max.244 byte

DP slave•Services

• PG/OP communicationYes

• Global data communicationNo

• S7 basic communicationNo

• S7 communicationYes

• S7 communication, as clientNo

Page 16: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1099 Mar 2008 Siemens ITS

• S7 communication, as serverYes; Connection configured on one sideonly

• Direct data exchange (slave-to-slavecommunication)

Yes

• DPV1No

•Transmission rate, max. 12 Mbit/s•Automatic baud rate search Yes; only with passive interface•Transfer memory

• Inputs244 byte

• Outputs244 byte

•Address area, max. 32•User data per address area, max. 32 byte2nd interfaceType of interface Integrated RS 485 interfacePhysics RS 485Isolated YesPower supply to interface (15 to 30 V DC),max.

200 mA

Functionality•MPI No

Page 17: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1100 Mar 2008 Siemens ITS

•DP master Yes•DP slave Yes•PROFINET IO Controller No•PROFINET IO Device No•PROFINET CBA No•Local Operating Network NoDP master•Services

• PG/OP communicationYes

• Global data communicationNo

• S7 basic communicationYes; I blocks only

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes; Connection configured on one sideonly

• Equidistance mode supportYes

• Isochronous modeYes; OB 61

Page 18: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1101 Mar 2008 Siemens ITS

• SYNC/FREEZEYes

• Activation/deactivation of DP slavesYes

• Number of DP slaves that can besimultaneously activated/deactivated,max.

8

• Direct data exchange (slave-to-slavecommunication)

Yes; As subscriber

• DPV1Yes

•Transmission rate, max. 12 Mbit/s•Number of DP slaves, max. 124•Address area

• Inputs, max.8 Kibyte

• Outputs, max.8 Kibyte

•User data per DP slave

• Inputs, max.244 byte

244 byte

Page 19: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1102 Mar 2008 Siemens ITS

• Outputs, max.DP slave•Services

• PG/OP communicationYes

• Global data communicationNo

• S7 basic communicationNo

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes; Connection configured on one sideonly

• Direct data exchange (slave-to-slavecommunication)

Yes

• DPV1No

•GSD file The latest GSD file is available at:http://www.siemens.de/profibus-gsd

•Transmission rate, max. 12 Mbit/s•Automatic baud rate search Yes; only with passive interface

Page 20: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1103 Mar 2008 Siemens ITS

•Transfer memory

• Inputs244 byte

• Outputs244 byte

•Address area, max. 32•User data per address area, max. 32 byte3rd interfaceType of interface PROFINETPhysics Ethernet RJ45Isolated YesIntegrated switch NoNumber of ports 1Power supply to interface (15 to 30 VDC), max.

0 mA

Automatic detection of transmission speed Yes; 10/100 Mbit/sAutonegotiation YesAutocrossing YesFunctionality•MPI No•DP master No•DP slave No•PROFINET IO Controller Yes•PROFINET IO Device No

Page 21: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1104 Mar 2008 Siemens ITS

•PROFINET CBA Yes•Local Operating Network NoPROFINET IO Controller•Services

• PG/OP communicationYes

• S7 communicationYes; with loadable FBs, max. configurableconnections: 16, max. number of instances:32

• Isochronous modeNo

• Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP

•Transmission rate, max. 100 Mbit/s•Number of connectable IO devices, max. 256•Max. number of connectable IO devicesfor RT

256

• of which in line, max.256

•Number of IO devices with IRT and theoption "high flexibility"

256

• of which in line, max.61

•Prioritized startup supported Yes

Page 22: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1105 Mar 2008 Siemens ITS

• Number of IO Devices, max.32

•Activation/deactivation of IO Devices Yes

• Number of IO Devices that can besimultaneously activated/deactivated,max.

8

•IO Devices changing during operation(partner ports), supported

Yes

• Max. number of IO devices per tool8

•Device replacement without swap medium Yes•Send cycles 250 µs, 500µs, 1 ms•Updating time 250 µs - 128 ms (with send cycle of 250

µs); 500 µs - 256 ms (with send cycle of500 µs); 1 ms - 512 ms (with send cycle1 ms); minimum value of the send cycle isalso dependent on the set communicationshare for PROFINET IO, on the number ofI/O devices, and on the volume ofconfigured user data.

•Updating times 250 µs - 128 ms (with send cycle of 250µs); 500 µs - 256 ms (with send cycle of500 µs); 1 ms - 512 ms (with send cycle

Page 23: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1106 Mar 2008 Siemens ITS

1 ms); minimum value of the send cycle isalso dependent on the set communicationshare for PROFINET IO, on the number ofI/O devices, and on the volume ofconfigured user data.

•Address area

• Inputs, max.8 Kibyte

• Outputs, max.8 Kibyte

•User data per address area, max.

• User data consistency, max.254 byte

Open IE communication•Open IE communication, supported Yes•Number of connections, max. 32•Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 8080,

34962, 34963, 34964, 65532, 65533, 65534,65535

Communication functionsPG/OP communication YesData record routing YesGlobal data communication•supported Yes

Page 24: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1107 Mar 2008 Siemens ITS

•Number of GD loops, max. 8•Number of GD packets, max. 8•Number of GD packets, transmitter, max. 8•Number of GD packets, receiver, max. 8•Size of GD packets, max. 22 byte•Size of GD packet (of which consistent),max.

22 byte

S7 basic communication•supported Yes•User data per job, max. 76 byte•User data per job (of which consistent),max.

76 byte; 76 bytes (with X_SEND orX_RCV); 64 bytes (with X_PUT orX_GET as server)

S7 communication•supported Yes•as server Yes•as client Yes; via integrated PROFINET interface and

loadable FB or via CP and loadable FB•User data per job, max. See online help of STEP 7 (shared

parameters of the SFBs/FBs and of theSFCs/FCs of S7 Communication)

S5-compatible communication•supported Yes; via CP and loadable FCOpen IE communication

Page 25: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1108 Mar 2008 Siemens ITS

•TCP/IP Yes; via integrated PROFINET interface andloadable FBs

• Number of connections, max.32

• Data length for connection type01H, max.

1 460 byte

• Data length for connection type11H, max.

8 192 byte

•ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface andloadable FBs

• Number of connections, max.32

• Data length, max.8 192 byte

•UDP Yes; via integrated PROFINET interface andloadable FBs

• Number of connections, max.32

• Data length, max.1 472 byte

Web server•supported Yes; only read function

Page 26: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1109 Mar 2008 Siemens ITS

•Number of HTTP clients 5PROFINET CBA (at set setpointcommunication load)•Setpoint for the CPU communication load 20 %•Number of remote interconnection partners 32•Number of functions, master/slave 50•Total of all Master/Slave connections 3 000•Data length of all incoming connectionsmaster/slave, max.

24 000 byte

•Data length of all outgoing connectionsmaster/slave, max.

24 000 byte

•Number of device-internal and PROFIBUSinterconnections

1 000

•Data length of device-internal undPROFIBUS interconnections, max.

8 000 byte

•Data length per connection, max. 1 400 byte•Remote interconnections with acyclictransmission

• Sampling frequency: Sampling time,min.

200 ms

• Number of incominginterconnections

100

Page 27: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1110 Mar 2008 Siemens ITS

• Number of outgoing interconnections100

• Data length of all incominginterconnections, max.

3 200 byte

• Data length of all outgoinginterconnections, max.

3 200 byte

• Data length per connection, max.1 400 byte

•Remote interconnections with cyclictransmission

• Transmission frequency:Transmission interval, min.

1 ms

• Number of incominginterconnections

300

• Number of outgoing interconnections300

• Data length of all incominginterconnections, max.

4 800 byte

4 800 byte

Page 28: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1111 Mar 2008 Siemens ITS

• Data length of all outgoinginterconnections, max.

4 800 byte

• Data length per connection, max.250 byte

•HMI variables via PROFINET (acyclic)

• Number of stations that can log onfor HMI variables (PN OPC/iMap)

3; 2x PN OPC/1x iMap

• HMI variable updating500 ms

• Number of HMI variables600

• Data length of all HMI variables,max.

9 600 byte

•PROFIBUS proxy functionality

• supportedYes

• Number of linked PROFIBUSdevices

32

• Data length per connection, max.240 byte; Slave-dependent

Page 29: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1112 Mar 2008 Siemens ITS

Number of connections•Max. total number of instances 32S7 message functionsNumber of login stations for messagefunctions, max.

32; Depending on the configuredconnections for PG/OP and S7 basiccommunication

Process diagnostic messages Yessimultaneously active Alarm-S blocks, max. 300Test commissioning functionsStatus/control•Status/control variable Yes•Variables Inputs, outputs, memory bits, DB, times,

counters•Number of variables, max. 30•of which status variables, max. 30•of which control variables, max. 14Forcing•Forcing Yes•Force, variables Inputs, outputs•Number of variables, max. 10Status block Yes; Up to 2 simultaneouslySingle step YesNumber of breakpoints 4Diagnostic buffer

Page 30: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1113 Mar 2008 Siemens ITS

•present Yes•Number of entries, max. 500

• adjustableNo

• Of which powerfail-proof100

•Number of entries readable in RUN, max.

• adjustableYes; From 10 to 499

• preset10

Isochronous modeIsochronous mode Yes; Via 2nd DP interfaceAmbient conditionsOperating temperature•Min. 0 °C•max. 60 °CConfigurationprogramming•Programming language

• LADYes

• FBDYes

Page 31: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1114 Mar 2008 Siemens ITS

• STLYes

• SCLYes

• CFCYes

• GRAPHYes

• HiGraph®Yes

•Command set see instruction list•Nesting levels 8Know-how protection•User program protection/passwordprotection

Yes

DimensionsWidth 120 mmHeight 125 mmDepth 130 mmWeightWeight, approx. 1 250 g

6ES7 318-3EL01-0AB0Product versionHardware product version 01

Page 32: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1115 Mar 2008 Siemens ITS

Firmware version V3.2General informationassociated programming package STEP7 V 5.5 or higherSupply voltage24 V DC YesInput currentCurrent consumption (rated value) 1 250 mACurrent consumption (in no-load operation),typ.

500 mA

Inrush current, typ. 4 AI²t 1.2 A²·sPower lossesPower loss, typ. 14 WMemoryWork memory•integrated 2 048 Kibyte•expandable No•Size of retentive memory for retentive datablocks

700 Kibyte

Load memory•pluggable (MMC) Yes•pluggable (MMC), max. 8 Mbyte•Data management on MMC (after lastprogramming), min.

10 a

Page 33: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1116 Mar 2008 Siemens ITS

Backup•present Yes•without battery YesCPU-blocksNumber of blocks (total) 4 096; (DBs, FCs, FBs); the maximum

number of loadable blocks can be reducedby the MMC used.

DB•Number, max. 4 096; Number range: 1 to 16000•Size, max. 64 KibyteFB•Number, max. 4 096; Number range: 0 to 7999•Size, max. 64 KibyteFC•Number, max. 4 096; Number range: 0 to 7999•Size, max. 64 KibyteOB•Size, max. 64 KibyteNesting depth•per priority class 16•additional within an error OB 4CPU processing timesfor bit operations, min. 0.004 µsfor word operations, min. 0.01 µs

Page 34: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1117 Mar 2008 Siemens ITS

for fixed point arithmetic, min. 0.01 µsfor floating point arithmetic, min. 0.04 µsCounters, timers and their retentivityS7 counter•Number 2 048•Retentivity

• adjustableYes

• lower limit0

• upper limit2 047

• presetZ 0 to Z 7

•Counting range

• adjustableYes

• lower limit0

• upper limit999

IEC counter•present Yes•Type SFB

Page 35: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1118 Mar 2008 Siemens ITS

•Number Unlimited (limited only by RAM capacity)S7 times•Number 2 048•Retentivity

• adjustableYes

• lower limit0

• upper limit2 047

• presetNo retentivity

•Time range

• lower limit10 ms

• upper limit9 990 s

IEC timer•present Yes•Type SFB•Number Unlimited (limited only by RAM capacity)Data areas and their retentivityretentive data area, total All, max. 700 KBFlag

Page 36: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1119 Mar 2008 Siemens ITS

•Number, max. 8 192 byte•Retentivity available Yes; MB 0 to MB 8191•Retentivity preset MB 0 to MB 15•Number of clock memories 8; 1 memory byteData blocks•Retentivity adjustable Yes; via non-retain property on DB•Retentivity preset YesLocal data•per priority class, max. 32 768 byte; Max. 2048 bytes per blockAddress areaI/O address area•Inputs 8 192 byte•Outputs 8 192 byte

Page 37: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1120 Mar 2008 Siemens ITS

•of which, distributed

• Inputs8 192 byte

• Outputs8 192 byte

Process image•Inputs, adjustable 8 192 byte•Outputs, adjustable 8 192 byte•Inputs, default 256 byte•Outputs, default 256 byteSubprocess images•Number of subprocess images, max. 1; With PROFINET IO, the length of the

user data is limited to 1600 bytesDigital channels•Inputs 65 536•Outputs 65 536•Inputs, of which central 1 024•Outputs, of which central 1 024Analog channels•Inputs 4 096•Outputs 4 096•Inputs, of which central 256•Outputs, of which central 256Hardware configuration

Page 38: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1121 Mar 2008 Siemens ITS

Racks, max. 4Modules per rack, max. 8Number of DP masters•integrated 2•via CP 4Number of operable FMs and CPs(recommended)•FM 8•CP, point-to-point 8•CP, LAN 10Time of dayClock•Hardware clock (real-time clock) Yes•battery-backed and synchronizable Yes•Deviation per day, max. 10 s; Typ.: 2 s•Backup time 6 wk; At 40 °C ambient temperature•Behavior of the clock following POWER-ON

Clock continues running after POWEROFF

•Behavior of the clock following expiry ofbackup period

Clock continues to run with the time atwhich the power failure occurred

Operating hours counter•Number 4•Number/Number range 0 to 3•Range of values 0 to 2^31 hours (when using SFC 101)

Page 39: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1122 Mar 2008 Siemens ITS

•Granularity 1 hour•retentive Yes; Must be restarted at each restartClock synchronization•supported Yes•to MPI, master Yes•to MPI, slave Yes•to DP, master Yes; With DP slave only slave clock•to DP, slave Yes•in AS, master Yes•in AS, slave Yes•on Ethernet via NTP Yes; as clientInterfacesNumber of USB interfaces 01st interfaceType of interface Integrated RS 485 interfacePhysics RS 485Isolated YesPower supply to interface (15 to 30 V DC),max.

150 mA

Functionality•MPI Yes•DP master Yes•DP slave Yes•Point-to-point connection No

Page 40: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1123 Mar 2008 Siemens ITS

MPI•Services

• PG/OP communicationYes

• RoutingYes

• Global data communicationYes

• S7 basic communicationYes

• S7 communicationYes

• S7 communication, as clientNo; but via CP and loadable FB

• S7 communication, as serverYes

•Transmission rate, max. 12 Mbit/sDP master•Services

• PG/OP communicationYes

• Global data communicationNo

Yes; I blocks only

Page 41: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1124 Mar 2008 Siemens ITS

• S7 basic communication

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes

• Equidistance mode supportYes

• Isochronous modeNo

• SYNC/FREEZEYes

• Activation/deactivation of DP slavesYes

• Number of DP slaves that can besimultaneously activated/deactivated,max.

8

• Direct data exchange (slave-to-slavecommunication)

Yes; As subscriber

• DPV1Yes

Page 42: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1125 Mar 2008 Siemens ITS

•Transmission rate, max. 12 Mbit/s•Number of DP slaves, max. 124•Address area

• Inputs, max.8 Kibyte

• Outputs, max.8 Kibyte

•User data per DP slave

• Inputs, max.244 byte

• Outputs, max.244 byte

DP slave•Services

• PG/OP communicationYes

• Global data communicationNo

• S7 basic communicationNo

• S7 communicationYes

• S7 communication, as clientNo

Page 43: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1126 Mar 2008 Siemens ITS

• S7 communication, as serverYes; Connection configured on one sideonly

• Direct data exchange (slave-to-slavecommunication)

Yes

• DPV1No

•Transmission rate, max. 12 Mbit/s•Automatic baud rate search Yes; only with passive interface•Transfer memory

• Inputs244 byte

• Outputs244 byte

•Address area, max. 32•User data per address area, max. 32 byte2nd interfaceType of interface Integrated RS 485 interfacePhysics RS 485Isolated YesPower supply to interface (15 to 30 VDC), max.

200 mA

Functionality•MPI No

Page 44: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1127 Mar 2008 Siemens ITS

•DP master Yes•DP slave Yes•PROFINET IO Controller No•PROFINET IO Device No•PROFINET CBA NoDP master•Services

• PG/OP communicationYes

• Global data communicationNo

• S7 basic communicationYes; I blocks only

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes; Connection configured on one sideonly

• Equidistance mode supportYes

• Isochronous modeYes; OB 61 - isochronous mode ispossible either on DP or PROFINET IO(not simultaneously)

Page 45: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1128 Mar 2008 Siemens ITS

• SYNC/FREEZEYes

• Activation/deactivation of DP slavesYes

• Number of DP slaves that can besimultaneously activated/deactivated,max.

8

• Direct data exchange (slave-to-slavecommunication)

Yes; As subscriber

• DPV1Yes

•Transmission rate, max. 12 Mbit/s•Number of DP slaves, max. 124•Address area

• Inputs, max.8 Kibyte

• Outputs, max.8 Kibyte

•User data per DP slave

• Inputs, max.244 byte

244 byte

Page 46: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1129 Mar 2008 Siemens ITS

• Outputs, max.DP slave•Services

• PG/OP communicationYes

• Global data communicationNo

• S7 basic communicationNo

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes; Connection configured on one sideonly

• Direct data exchange (slave-to-slavecommunication)

Yes

• DPV1No

•GSD file The latest GSD file is available at:http://www.siemens.de/profibus-gsd

•Transmission rate, max. 12 Mbit/s•Automatic baud rate search Yes; only with passive interface

Page 47: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1130 Mar 2008 Siemens ITS

•Transfer memory

• Inputs244 byte

• Outputs244 byte

•Address area, max. 32•User data per address area, max. 32 byte3rd interfaceType of interface PROFINETPhysics Ethernet RJ45Isolated YesIntegrated switch YesNumber of ports 2Automatic detection of transmission speed Yes; 10/100 Mbit/sAutonegotiation YesAutocrossing YesMedia redundancy•supported Yes•Switchover time on line break, typically 200 ms; PROFINET MRP•Number of stations in the ring, max. 50Change of IP address at runtime, supported YesFunctionality•MPI No•DP master No

Page 48: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1131 Mar 2008 Siemens ITS

•DP slave No•PROFINET IO Controller Yes; Also simultaneously with I-Device

functionality•PROFINET IO Device Yes; Also simultaneously with IO Controller

functionality•PROFINET CBA YesPROFINET IO Controller•Services

• PG/OP communicationYes

• S7 communicationYes; with loadable FBs, max. configurableconnections: 16, max. number of instances:32

• Isochronous modeYes; OB 61 - isochronous mode is possibleeither on DP or PROFINET IO (notsimultaneously)

• Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP

•Transmission rate, max. 100 Mbit/s•Number of connectable IO devices, max. 256•Max. number of connectable IO devicesfor RT

256

• of which in line, max.256

Page 49: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1132 Mar 2008 Siemens ITS

•Number of IO devices with IRT and theoption "high flexibility"

256

• of which in line, max.61

•Number of IO Devices with IRT and theoption "high performance", max.

64

• of which in line, max.64

•Shared device, supported Yes•Prioritized startup supported Yes

• Number of IO Devices, max.32

•Activation/deactivation of IO Devices Yes

• Number of IO Devices that can besimultaneously activated/deactivated,max.

8

•IO Devices changing during operation(partner ports), supported

Yes

• Max. number of IO devices per tool8

•Device replacement without swap medium Yes•Send cycles 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in

the case of IRT with "high flexibility"

Page 50: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1133 Mar 2008 Siemens ITS

option)•Updating time 250 µs to 512 ms (depending on the

operating mode, see Manual "S7-300 CPU31xC and CPU 31x, Technical Data" formore details)

•Address area

• Inputs, max.8 Kibyte

• Outputs, max.8 Kibyte

•User data per address area, max.

• User data consistency, max.1 024 byte

PROFINET IO Device•Services

• PG/OP communicationYes

• RoutingYes

• S7 communicationYes; with loadable FBs, max. configurableconnections: 16, max. number of instances:32

• Isochronous modeNo

Page 51: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1134 Mar 2008 Siemens ITS

• Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP

• IRT, supportedYes

• PROFIenergy, supportedYes; With SFB 73 / 74 prepared forloadable PROFIenergy standard FB for I-Device

• Shared device, supportedYes

• Number of IO controllers withshared device, max.

2

•Transfer memory

• Inputs, max.1 440 byte; Per IO Controller with shareddevice

• Outputs, max.1 440 byte; Per IO Controller with shareddevice

•Submodules

• Number, max.64

• User data per submodule, max.1 024 byte

Open IE communication•Open IE communication, supported Yes

Page 52: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1135 Mar 2008 Siemens ITS

•Number of connections, max. 32•Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 8080,

34962, 34963, 34964, 65532, 65533, 65534,65535

•Keep-alive function, supported YesCommunication functionsPG/OP communication YesData record routing YesGlobal data communication•supported Yes•Number of GD loops, max. 8•Number of GD packets, max. 8•Number of GD packets, transmitter, max. 8•Number of GD packets, receiver, max. 8•Size of GD packets, max. 22 byte•Size of GD packet (of which consistent),max.

22 byte

S7 basic communication•supported Yes•User data per job, max. 76 byte•User data per job (of which consistent),max.

76 byte; 76 bytes (with X_SEND orX_RCV); 64 bytes (with X_PUT orX_GET as server)

S7 communication

Page 53: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1136 Mar 2008 Siemens ITS

•supported Yes•as server Yes•as client Yes; via integrated PROFINET interface and

loadable FB or via CP and loadable FB•User data per job, max. See online help of STEP 7 (shared

parameters of the SFBs/FBs and of theSFCs/FCs of S7 Communication)

S5-compatible communication•supported Yes; via CP and loadable FCOpen IE communication•TCP/IP Yes; via integrated PROFINET interface and

loadable FBs

• Number of connections, max.32

• Data length for connection type01H, max.

1 460 byte

• Data length for connection type11H, max.

32 768 byte

• Several passive connections per port,supported

Yes

•ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and

Page 54: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1137 Mar 2008 Siemens ITS

loadable FBs

• Number of connections, max.32

• Data length, max.32 768 byte

•UDP Yes; via integrated PROFINET interface andloadable FBs

• Number of connections, max.32

• Data length, max.1 472 byte

Web server•supported Yes•Number of HTTP clients 5•User-defined websites YesPROFINET CBA (at set setpointcommunication load)•Setpoint for the CPU communication load 20 %•Number of remote interconnection partners 32•Number of functions, master/slave 50•Total of all Master/Slave connections 3 000•Data length of all incoming connectionsmaster/slave, max.

24 000 byte

•Data length of all outgoing connections 24 000 byte

Page 55: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1138 Mar 2008 Siemens ITS

master/slave, max.•Number of device-internal and PROFIBUSinterconnections

1 000

•Data length of device-internal undPROFIBUS interconnections, max.

8 000 byte

•Data length per connection, max. 1 400 byte•Remote interconnections with acyclictransmission

• Sampling frequency: Sampling time,min.

200 ms

• Number of incominginterconnections

100

• Number of outgoing interconnections100

• Data length of all incominginterconnections, max.

3 200 byte

• Data length of all outgoinginterconnections, max.

3 200 byte

• Data length per connection, max.1 400 byte

Page 56: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1139 Mar 2008 Siemens ITS

•Remote interconnections with cyclictransmission

• Transmission frequency:Transmission interval, min.

1 ms

• Number of incominginterconnections

300

• Number of outgoing interconnections300

• Data length of all incominginterconnections, max.

4 800 byte

• Data length of all outgoinginterconnections, max.

4 800 byte

• Data length per connection, max.450 byte

•HMI variables via PROFINET (acyclic)

• Number of stations that can log onfor HMI variables (PN OPC/iMap)

3; 2x PN OPC/1x iMap

• HMI variable updating500 ms

Page 57: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1140 Mar 2008 Siemens ITS

• Number of HMI variables600

• Data length of all HMI variables,max.

9 600 byte

•PROFIBUS proxy functionality

• supportedYes

• Number of linked PROFIBUSdevices

32

• Data length per connection, max.240 byte; Slave-dependent

Number of connections•Max. total number of instances 32•usable for routing X1 as MPI: max. 10; X1 as DP master:

max. 24; X1 as DP slave (active): max.14; X2 as DP master: max. 24; X2 as DPslave (active): max. 14; X3 as PROFINET:48 max.

S7 message functionsNumber of login stations for messagefunctions, max.

32; Depending on the configuredconnections for PG/OP and S7 basiccommunication

Page 58: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1141 Mar 2008 Siemens ITS

Process diagnostic messages Yessimultaneously active Alarm-S blocks, max. 300Test commissioning functionsStatus/control•Status/control variable Yes•Variables Inputs, outputs, memory bits, DB, times,

counters•Number of variables, max. 30•of which status variables, max. 30•of which control variables, max. 14Forcing•Forcing Yes•Force, variables Inputs, outputs•Number of variables, max. 10Status block Yes; Up to 2 simultaneouslySingle step YesNumber of breakpoints 4Diagnostic buffer•present Yes•Number of entries, max. 500

• adjustableNo

• Of which powerfail-proof100

Page 59: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1142 Mar 2008 Siemens ITS

•Number of entries readable in RUN, max. 499

• adjustableYes; From 10 to 499

• preset10

Isochronous modeIsochronous mode Yes; Via 2nd PROFIBUS DP or

PROFINET interfaceAmbient conditionsOperating temperature•Min. 0 °C•max. 60 °CConfigurationprogramming•Programming language

• LADYes

• FBDYes

• STLYes

• SCLYes

Yes

Page 60: CPU 319-3 PN/DP · PDF filethe last 500 error and interrupt events are stored in a buffer for diagnostic purposes, ... •retentive Yes; Must be restarted at each restart Clock synchronization

Page 1143 Mar 2008 Siemens ITS

• CFC

• GRAPHYes

• HiGraph®Yes

•Command set see instruction list•Nesting levels 8Know-how protection•User program protection/passwordprotection

Yes

•Block encryption Yes; With S7 block PrivacyDimensionsWidth 120 mmHeight 125 mmDepth 130 mmWeightWeight, approx. 1 250 g