consumer access dimensions - diebold nixdorf · consult with diebold nixdorf installation/service...

5
SUBJ ECT TO CHANGE W THOUT NOTCE" " ALLDMENSONS AND DESGN CRTERA PROJ ECT I ON T HI RD ANGLE ( DI MENSI ONS I N I NCHES) DI MENSI ONS I N MI LL I MET RES PAGE 1 OF 5 L 1251 CALL 1-800-999-3600 F I LE NO. 177 - 697 REV. 0 PLAN VIEW FRONT ELEVATION SIDE ELEVATION G H J K B C A E D F L I 670 ") 8 3 (26 1158 " ) 16 9 ( 45 643 ") 16 5 (25 1637 " ) 16 7 ( 64 670 ") 8 3 (26 643 ") 16 5 (25 1158 ") 8 5 (45 197 ") 8 3 (14 366 ") 4 3 (7 1637 " ) 16 7 ( 64 573 " ) 16 9 ( 22 1605 " ) 16 3 ( 63 " ) 8 1 ( 3 80 " ) 8 7 ( 1 48 1024 ") 16 5 (40 768 ") 4 1 (30 AIR VENTS SAFE DEPTH DIMENSIONS EDGE OF BEZEL FOR REFERENCE FRONT SAFE SAFE O 19" DISPLAY N 15" DISPLAY SHOWN 15" DISPLAY SHOWN HEIGHT - FROM BOTTOM OF SAFE DEPTH - FROM FRONT EDGE OF BEZEL TERMINAL WITH 15” AND 19” DISPLAYS SHARE ALL THE SAME DIMENSIONS EXCEPT DISPLAY SIZE AND FUNCTION KEYS ARE NOT AVAILABLE ON THE 19” DISPLAY THE FRONT EDGE OF BEZEL THAT EXTEND OUT TOWARD THE CUSTOMER FROM DEPTH DIMENSIONS MARKED SHOW COMPONENTS * M HEIGHT DEPTH A B E C D ") 8 1 (52 1324mm CONSUMER ACCESS DIMENSIONS ") 16 13 (6 172mm ") 16 7 (5 138mm ") 16 11 (43 1109mm ") 8 5 (36 930mm F RECEIPT PRINTER G H I J K L ") 16 9 (31 802mm ") 8 1 (44 1121mm HEADPHONE JACK ") 8 5 (36 931mm ") 16 9 (36 928mm ") 16 11 (31 805mm ") 4 3 (31 807mm BOTTOM OF CONSUMER DISPLAY TOP OF CONSUMER DISPLAY TOP FUNCTION KEY COIN DISPENSER (OPTIONAL) CONTACTLESS CARD READER (OPTIONAL) ActivCheck EMV-READY CARD READER ActivRecycle EPP KEY FINGERPRINT READER (OPTIONAL) ") 2 1 (5 139mm ") 16 1 ( 2mm ") 16 9 (8 217mm ") 4 3 (7 197mm ") 4 3 (7 197mm ") 4 3 (7 197mm ") 4 3 (7 197mm ") 16 7 (5 138mm (39") 991mm ") 16 15 (31 810mm M N ") 4 3 (54 1390mm ") 16 9 (43 1106mm TOP OF 19" CONSUMER DISPLAY BOTTOM OF 19" CONSUMER DISPLAY ") 8 3 (9 239mm ") 8 3 (5 136mm (48") 1219mm O 2D BAR CODE SCANNER (OPTIONAL) ") 16 7 (- 2 - 61mm * * * ") 16 1 (-1 -27mm ") 4 3 (- -18mm ") 8 5 (29 752mm "T O 3 " ) 16 7 LEVEL NG RANGE 11 mm T O 76 mm ( SAF E SEE PLANNING AND SITE PREPARATION GUIDE TP-821975-001. BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE ") UL SAFE 2 1 WITH 13mm ( 15" DISPLAY OR 19" DISPLAY CS 3700 LOBBY CASH RECYCLER- FRONT LOAD

Upload: others

Post on 27-Mar-2020

72 views

Category:

Documents


4 download

TRANSCRIPT

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

PR

OJE

CTIO

N

THIR

D A

NG

LE

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

PA

GE 1 O

F 5

L1251

CALL 1-800-999-3600FIL

E N

O. 177-6

97 R

EV. 0

PLAN VIEW

FRONT ELEVATIONSIDE ELEVATION

G

H

J

K

B

C

A

E

D

F

L

I

670

")83(26

1158

")16

9(4

5

643

")165(25

1637

")16

7(6

4

670

")83(26

643

")165(25

1158

")85(45

197

")83(14

366

")43(7

1637

")16

7(6

4

573

")16

9(2

2

1605

")16

3(6

3

")8

1(3

80

")8

7(1

48

1024

")165(40

768

")41(30

AIR VENTS

SAFE

DEPTH DIMENSIONS

EDGE OF BEZEL FOR

REFERENCE FRONT

SAFE

SAFE

O

19" DISPLAY

N

15" DISPLAY SHOWN

15" DISPLAY SHOWN

HEIGHT - FROM BOTTOM OF SAFE

DEPTH - FROM FRONT EDGE OF BEZEL

TERMINAL WITH 15” AND 19” DISPLAYSSHARE ALL THE SAME DIMENSIONS EXCEPT

DISPLAY SIZE AND FUNCTION KEYS ARE NOT

AVAILABLE ON THE 19” DISPLAY

THE FRONT EDGE OF BEZEL

THAT EXTEND OUT TOWARD THE CUSTOMER FROM

DEPTH DIMENSIONS MARKED SHOW COMPONENTS *

M

HEIGHT DEPTH

A

B

E

C

D

")81(52

1324mm

CONSUMER ACCESS DIMENSIONS

")1613(6

172mm

")167(5

138mm

")1611(43

1109mm

")85(36

930mm

F

RECEIPT PRINTER

G

H

I

J

K

L

")169(31

802mm

")81(44

1121mmHEADPHONE JACK

")85(36

931mm

")169(36

928mm

")1611(31

805mm

")43(31

807mm

BOTTOM OF CONSUMER DISPLAY

TOP OF CONSUMER DISPLAY

TOP FUNCTION KEY

COIN DISPENSER (OPTIONAL)

CONTACTLESS CARD READER (OPTIONAL)

ActivCheck

EMV-READY CARD READER

ActivRecycle

EPP KEY

FINGERPRINT READER (OPTIONAL)

")21(5

139mm

")161(

2mm

")169(8

217mm

")43(7

197mm

")43(7

197mm

")43(7

197mm

")43(7

197mm

")167(5

138mm

(39")

991mm

")1615(31

810mm

M

N ")43(54

1390mm

")169(43

1106mm

TOP OF 19" CONSUMER DISPLAY

BOTTOM OF 19" CONSUMER DISPLAY

")83(9

239mm

")83(5

136mm

(48")

1219mm

O

2D BAR CODE SCANNER (OPTIONAL)")16

7(- 2

- 61mm **

*

")161(-1

-27mm

")43(-

-18mm

")85(29

752mm

" T

O 3")

16

7L

EV

ELIN

G R

AN

GE 1

1m

m T

O 7

6m

m (

SA

FE

SEE PLANNING AND SITE PREPARATION GUIDE TP-821975-001.

BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE

CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE

") UL SAFE21WITH 13mm (

15" DISPLAY OR 19" DISPLAY

CS 3700 LOBBY CASH RECYCLER- FRONT LOAD

LOW ABSOLUTE HUMIDITY 1g WATER / Kg DRY AIR

HIGH ABSOLUTE HUMIDITY 32g WATER / Kg DRY AIR (MAXIMUM WET BULB 35°C)

MAX RATE OF CHANGE 10% PER HOUR

RELATIVE HUMIDITY (NON-CONDENSING) (INSIDE) 20% TO 80%

MAX RATE OF CHANGE 10°C (18°F) PER HOUR

0°C TO 38°C (0°F TO 100°F)

TEMPERATURE (INSIDE AT OUTSIDE WALLS OF UPPER CABINET AND SAFE)

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

PA

GE 2 O

F 5

EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.

NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR

4

NOTE:

200-240 VAC (±10%) SERVICE, DISCONNECT AT 10 AMPERES

100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES

SIGNAL CABLE RUN CONSTRAINTS

ELECTRICAL EQUIPMENT CABLE RUN.

OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND

THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS

AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION.

POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION

RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE

SIGNAL CABLE INSTALLATION CONSTRAINTS:

WEIGHT OF UNIT:

POWER USAGE:

HEAT OUTPUT CONFIGURATION:

POWER REQUIREMENTS:CONDUIT AND JUNCTION BOX REQUIREMENTS

PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA.

CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF

SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.

POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO

THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE

(SEE POWER REQUIREMENTS).

MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNER'S E.C.)

WITHIN 2210mm (87") OF SIDE CONNECTING PLATE. BOTTOM CONNECTION

") DEEP JUNCTION BOX WITH RECEPTACLE81102mm (4") SQ. X 54mm (2

") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 4319mm (

LENGTH 2210mm (87") FROM SIDE OF UNIT.

SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD

OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY

1

2

3

(OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.

BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE

SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT

POWER TO THE TERMINAL IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A

POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW.

IS NOT ACCEPTABLE). THE TERMINAL WILL PROVIDE A POWER CORD WITH A COUNTRY SPECIFIC

WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND

THE TERMINAL REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE.

CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE:

200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE

200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE

100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE

100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE

TYPE OF ELECTRICAL RUN

LIGHTING FIXTURES

FLUORESCENT, NEON OR INCANDESCENT

ELECTRICAL EQUIPMENT

UNSHIELDED POWER LINE OR

CONDUIT

WITH SIGNAL CABLES IN GROUNDED

POWER LINES IN GROUNDED CONDUIT

BELOW 2 KVA 2-5 KVA ABOVE 5 KVA

127mm (5") 127mm (5") 127mm (5")

127mm (5") 305mm (1'-0") 610mm (2'-0")

")2164mm (2 152mm (6") 305mm (1'-0")

")16330mm (1 76mm (3") 152mm (6")

GROUNDED CONDUIT

SIGNAL CABLES ENCLOSED IN

ELECTRICAL EQUIPMENT WITH

UNSHIELDED POWER LINES OR

SEPARATION FROM OTHER CABLES

OPERATING ENVIRONMENT:

BACK ELEVATION

SIDE ELEVATION

201

")167(14

366

")87(7

")8

1(3

79

")8

7(1

48

768

")41(30

1158

")169(45

643

")165(25

670

")83(26

154

")87(5

150

")167(14

366

")161(6

")8

1(3

80

")8

7(1

48

1604 ")8

1(6

3

AIR VENTS

366

")21(1

38")167(14

1024

")165(40

SAFE

OF UNIT

2210mm (87") FROM SIDE

POWER CORD - LENGTH

573

")8

1(3

80

")8

5(1

42

")16

9(2

2

1

3

1

4

2

3 1637

")16

7(6

4

AIR VENTS

AIR VENTS

")RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTION PLATE.4319mm (

") LIQUID TIGHT FLEX METAL CONDUIT OR 43OWNER'S E.C. TO RUN 19mm (

IDLE (NO TRANSACTION)

IN PROGRESS)

TRANSACTION (DISPENSE

CONFIGURATION

A

A

CHARGING

WITH BATTERY

A

382 WATTS

STD LCD DISPLAY

NO HEATER

MACHINE STATUS

125 WATTS

374 WATTS

133 WATTS

ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED.

RECYCLER AND THE TYPE OF TRANSACTION THE RECYCLER IS PERFORMING. VALUES

THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE

JOURNAL PRINTER, IDM BD, COIN DISPENSER AND ECRM LITE

REAR TOUCH SCREENS, SECURE CARD READER, RECEIPT PRINTER (SNOWHAVEN),

PROCESSOR (HPSTD), CCR2, EPP7 AND FUNCTION KEY, REAR DISPLAY, FRONT AND

454 BTU/HR DISPENSING

427 BTU/HR IDLEA

1276 BTU/HR IDLE

1303 BTU/HR DISPENSINGA

CHARGING

WITH BATTERY

SAFE

SWITCH IS PROVIDED BY THE DNA SERVICE ORGANIZATION.

BOX. (ALL BY OWNER'S E.C.) DNA ONLY-FLAT COVER WITH TAMPER

") DEEP JUNCTI0N 81JUNCTION BOX TO 102mm (4") SQ. X 54mm (2

25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET

CONFIGURATION OF THE TERMINAL COMPONENTS AND OPTIONS

ACTUAL WEIGHT OF THE TERMINAL WILL DEPEND ON THE

757 kg (1,169 LBS.)

" T

O 3")

16

7L

EV

ELIN

G R

AN

GE 1

1m

m T

O 7

6m

m (

1605

")16

3(6

3

573

")16

9(2

2

SA

FE

FIL

E N

O. 177-6

97 R

EV. 0

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

PA

GE 3 O

F 5

FIL

E N

O. 177-6

97 R

EV. 0

RECOMMENDED SERVICE AREA

MUST ENTER UNIT IN THIS AREA

ALL ELECTRICAL AND DATA CABLES

SIDE ELEVATION

MINIMUM SERVICE AREA

RECOMMENDED SERVICE AREA

PLAN VIEW

MINIMUM SERVICE AREA

PLAN VIEW

2443

")163(96

1789

")16

7(7

0

NOTE:

342

(12")

305

")1613(

20

")165(25

643

(6")

152

")167(13

1462

")169(57

")16

13

(491265

")16

9(4

51158

")16

13

(

20

767

")16

3(3

0

2443

")16

3(9

6

1158

")16

13

(491265

")8

5(4

5

309

(6")

152

")16

3(1

2 (2")

50

910

")16

13

(35

2443

")16

3(9

6

")16

13

(491265

")8

5(4

5

1158

")16

13

(

20 315

(12")

305

")1613(

20

")165(25

643

")1613(12

325

")83(12

1608

")165(63

309

(6")

152

")16

3(1

2 (2")

50

1158

")16

13

(491265

")16

9(4

5

910

")16

13

(35

SAFE SAFE

TE

RMIN

AL

TE

RMIN

AL

FRONT LOAD - SERVICE AREAS

CS 3700 LOBBY CASH RECYCLER

FOR SERVICE AREA OF ADJACENT UNITS SEE PAGE 4 OF 5

DIEBOLD NIXDORF INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS.

MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH

INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE MINIMUM AREA

SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE

SHOWN ARE THE MINIMUM AND RECOMMENDED AREA REQUIRED FOR INSTALLATION AND

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

PA

GE 4 O

F 5

PLAN VIEW - ADJACENT UNITS (MINIMUM SERVICE AREA)

MINIMUM SERVICE AREA

IN THIS AREA

CABLES MUST ENTER UNIT

ALL ELECTRICAL AND DATA

3453

")1615(135

")16

13

(491265

")16

9(4

51158

")16

13

(

20

767

")16

3(3

0

2443

")16

3(9

6

309

(6")

152

")16

3(1

2 (2")

50

SAFE

1158

")16

13

(491266

")16

9(4

5

910

")16

13

(35

342

")1613(

20

")165(25

643

")87(13

352

")165(25

643

")87(13

352

")165(25

643

(6")

152

")167(13

480

")41(12

312

")83(26

670

")1613(12

325

")83(26

670

")1613(12

325

")83(26

670

")1615(18

SERVICE AREA - ADJACENT UNITS

TE

RMIN

AL

(12")

305SAFE SAFE

FIL

E N

O. 177-6

97 R

EV. 0

FIL

E N

O. 177-6

97 R

EV. 0

ALARM CABLES (SIDE ENTRY)

") DIA. HOLE FOR8129mm (1

POWER CABLE PLATE

(SIDE ENTRY)

CORD AND DATA CABLES

OPENINGS FOR POWER

SAFE FLOOR MOUNTING DETAILS

CABLE ENTRY NOTE

2 (4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES

") DIA. LEVELING LEG HOLES1691 (4) 14mm (

PLAN VIEW - SAFE FLOOR

SEE NOTE

CABLE ENTRY

1

2

1

2

1

SAFE

SA

FE

1023

")16

5(4

0

")167(1

36

")21(22

571")16

7(1

36

1

2 2

NOTES:FOR ADDED SECURITY:

ANCHORING SAFE TO CONCRETE FLOORS:

ANCHORING THE CASH DISPENSER TO WOOD FLOORING:

ANCHORING THE CASH DISPENSER TO STEEL FLOORS:

").21BE AT LEAST 13mm (

PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR THICKNESS MUST

A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO

OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO

METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS

CASH DISPENSER INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED

USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR YOUR INSTALLATION.

IT IS RECOMMENDED THAT THE TERMINAL SAFE BE SECURED TO THE FLOOR WITH ANCHOR BOLTS.

HOLDING CAPACITY OF A WOOD FLOOR WILL BE LESS THAN THAT OF CONCRETE FLOORS.

") THICK. IT IS IMPORTANT TO NOTE THAT THE OVERALL 41STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (

TO A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL

SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH

BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS PREFERRED THAT THE HARDWARE BE ATTACHED THROUGH

CASH DISPENSERS INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODEN BEAMS CAN BE SECURED

")8

3(2

6670

(6")

152

366

")2

1(1

38

")16

7(1

4

")16

9(5

142

")16

7(3

3849

")16

5(1

33

")83(3

85

(19")

483

")1615(2

75

IS NO LIMIT FOR MAXIMUM THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES.

FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm (4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE

") ANCHOR BOLT THAT IS 203mm (8") LONG. CONCRETE 43DIEBOLD NIXDORF RECOMMENDS USING A M20 OR 19mm (

IT IS RECOMMENDED THAT THE TERMINAL SAFE BE ANCHORED TO CONCRETE FLOORS WHENEVER POSSIBLE.

OF THE SAFE AS VIEWED FROM THE FRONT OF THE TERMINAL.

OPENING. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE

THE INTERIOR SIDE WALL OF THE SAFE AT THE CABLE ENTRY

SAFE AND THROUGH A RESTRICTOR BRACKET ATTACHED ON

CABLE PLATE ATTACHED TO THE EXTERIOR SIDE WALL OF THE

CABLES ENTERING THE TERMINAL PASS THROUGH THE POWER

THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE.

ELECTRICAL AND DATA CABLING ENTERS THE TERMINAL

(8")

203

MIN.

(4")

102

MIN.

203mm (8")

MINIMUM HOLE DEPTH

102mm (4")

MINIMUM CONCRETE DEPTH

VIEW "A" VIEW "B"

DIEBOLD NIXDORF PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520).

")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER'S INSTALLER) 4319mm (

WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4)

IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR

") DIA. X 203mm (8" MIN.) DEEP HOLES43OWNER'S INSTALLER TO DRILL (4) 19mm (

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

PA

GE 5 O

F 5

643

")165(25