GOVERNING SPECIFICATIONS
THE SPECIFICATIONS AS PREPARED BY IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP AND BOLTON & MENK.INC. SHALL BE CONSIDERED AS PART OF THIS DOCUMENT. NATURAL RESOURCES CONSERVATION SERVICE CONSTRUCTION SPECIFICATIONS SHALL APPLY.
THE 2018 EDITION OF THE "IOWA STATEWIDE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" SHALL ALSO GOVERN AS SPECIFIED.
ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES WILL BE COMPLIED WITH IN THE CONSTRUCTION OF THIS PROJECT,
PLAN REVISIONS REV ISSUED FOR DATE
A FINAL 9/201B
1 IDALS COMMENTS 10/2018
/ SAC COUNTY
I
PROJECT LOCATION
Cel Be� Yoo., Oi;I
1.800.292.8989 Call lhe 1011"�- .,..,_ _ -
48 llOUr:$ l"IO'ID L�•lnlowa
NOTE: EXISTING UTILITY INFORMATION SHOWN ON THIS PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS PRIOR TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE LAW. NOTIFY IOWA ONE CALL, 1-800-292-8989,
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY LEVEL D. THIS UTILITY QUALITY LEVEL WAS
DETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA."
1C1 lk,J'lon & ¥, M. lpc..1011, Alf IUf,hll Reserved k."'\!OAli\AU11\016\CAO\ODUhut Dwp 10.11\J 1S0'1;_6C1Jl.dw& l0/ll/JOl811:ll AM
20
li
31
�<OlM�
r6\
�RROLL CO.
L
CONSTRUCTION PLANS FOR
CREP PROJECT NO. SAC863635B SITE GRADING, BERM CONSTRUCTION, SHEET PILE, RIP RAP AND ARMORING
WETLAND SEEDING, DRAIN TILE, EROSION AND SEDIMENT CONTROL
SEPTEMBER 2018
"'
)ll)IHU
"' ?;
25 <
i@?;g JJ) � / l?D1rfS1
36 31 32 3)
R-36W
MAP OF PORTIONS OF
SAC COUNTY, IOWA
MAP LEGEND
- PROJECT LIMITS
11\BOLTON "1l/&MENK
300 WEST MCKINLEY ST, PO BOX 6B JEFFERSON, IOWA 50129
Phone: (515)-386-4101 Email: [email protected]
www.bofton-menJc.com
l 61
� � :!
�
R-35W
( I I
�( 23
l'mfH$1
i'.' 26 /� !! :.
"I
..,
z
·tu �;; 26
u
:i:
CARROLL CO.
SHEET NO.
1.0 1.1
1.2 2.0
3.0 4.0
4.1
4.2
5.0
5.1
5.2
6.0
6.1 6.2
7.0
7,1
8.0
9.0
9.1
SHEET INDEX
SHEET TITLE
TITLE SHEET ESTIMATED QUANTITIES AND REFERENCE NOTES LEGEND EXISTING SITE CONDITIONS PROPOSED SITE CONDITIONS BERM PLAN PROFILE BERM PLAN PROFILE BERM TOE DRAIN PLAN AND PROFILE WATER CONTROL STRUCTURE, OUTLET PIPE PLAN AND PROFILE SLOTTED INTAKE RISER AND OUTLET PIPE DETAILS WATER CONTROL AND STOP LOG STRUCTURE DETAILS
DRAIN TILE NO. 1 OUTLET PLAN AND PROFILE DRAIN TILE NO. 2 OUTLET PLAN AND PROFILE DRAIN TILE NO. 3 OUTLET PLAN AND PROFILE STILLING BASIN PLAN AND PROFILE SHEET PILE SECTION AND DETAILS SEEDING AREAS WETLAND CENTERLINE PLAN AND PROFILE WETLAND CENTERLINE PLAN AND PROFILE
THIS PLAN SET CONTAINS 19 SHEETS.
I HEREBY CERTIFY THATTHIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION M THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
0 R THE LAWS OF THE STATE OF IOWA,
REG. NO. 17000
MY LICENSE RENEWAL DATE IS 12/31/2019
PAGES OR SHEETS COVERED BY THIS SEAL:
AUSHEffi
PROJECT DATUM: IRCS-4 ,.,,,,"ss�;=•=,..=""""""==1-1-0_W_A_ D _E _PA_ R_T_M __ EN_ T _O _F _A_G_R_IC_U_L _T_U _R _E A_N _D _LA_N_D_ S_T_E_W_A_ R_D_S _H _IP-, ""'~' SAC COUNTY CREP PROJECT NO. SAC863635C
SHEET
LOCATION: SIOUX CITY - IOWA FALLS 1.0 TITLE SHEET
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_G01
.1.d
wg
10/2
6/20
18 1
0:38
:28
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
1.1ESTIMATED QUANTITIES AND REFERENCE NOTES
1.1ESTIMATED QUANTITIES AND REFERENCE NOTES
ESTIMATED PROJECT QUANTITIESITEM NO. WORK OR MATERIAL SPEC NO. ESTIMATED
QUANTITY UNIT AS-BUILTQUANTITY
1 TOPSOIL STRIPPING, SALVAGE AND RESPREAD IA-1, IA-26 3,430 CY2 CLEARING AND GRUBBING IA-1 1 LS3 STRUCTURE AND CHANNEL FERTILIZER & SEEDING IA-6 1.0 AC4 BUFFER SEEDING IA-6 15.4 AC5 MOBILIZATION/DEMOBILIZATION IA-8 1 LS6 DRAINAGE TILE INVESTIGATION AND REMOVAL IA-9 1 LS7 STEEL SHEET PILE IA-13,IA-81 1,307 SF8 EXCAVATION, EARTH FILL IA-21, IA-23 7,100 CY9 DRAINFILL, FINE IA-24 24 CY
10 PERFORATED CORRUGATED POLYETHYLENE TUBING, 6" DIAMETER IA-46 286 LF11 HDPE, 12" DIAMETER, NON-PERFORATED IA-46 397 LF12 RCP, 24" DIAMETER IA-46 576 LF13 DRAWDOWN PIPE, CMP, 18" DIAMETER, NON-PERFORATED IA-51 120 LF14 INLINE WATER CONTROL STRUCTURE STOP GATE, CMP, 48" IA-51 1 EA15 CMP OUTLET PIPE, 12" DIAMETER IA-51 40 LF16 CMP OUTLET PIPE, 18" DIAMETER IA-51 40 LF17 CMP OUTLET PIPE, 30" DIAMETER IA-51 20 LF18 RIPRAP, CLASS E IA-61, IA-95 540 TN19 CONCRETE GROUT IA-62 68 CY
ESTIMATE REFERENCE INFORMATIONITEM NO. DESCRIPTION
1 TOPSOIL STRIPPING, SALVAGE AND RESPREADTHIS IS THE QUANTITY TO REMOVE, SALVAGE AND STOCKPILE 12" OF EXISTING MATERIAL FROM ALL AREAS TO BE EXCAVATED OR DISTURBED. ALL AREAS TO RECEIVE SEED, BORROW
AREAS AND EXCAVATIONS BELOW THE NORMAL POOL ELEVATION SHALL HAVE A MINIMUM OF 6" OF TOPSOIL PLACED.
2 CLEARING AND GRUBBINGTHIS SHALL BE CONSIDERED FULL COMPENSATION TO REMOVE ALL TREES, STUMPS AND BRUSH FROM WITHIN THE NORMAL POOL ONLY.
3 STRUCTURE AND CHANNEL FERTILIZER & SEEDINGTHIS SEED IS FOR THE EMBANKMENT AND BERM AREA, OUTLET CHANNEL AREA, TILE OUTLET AREAS AND AREAS WHERE THE GROUND SLOPES WILL BE STEEPER THAN 5:1.
THIS WILL INCLUDE ANY TOPSOIL WASTE AREAS OR SLOPES FROM THE BORROW AREA TO THE EXISTING GROUND. MULCHING SHALL BE INCLUDED FOR THIS AREA.
4 BUFFER SEEDING
THIS SEED IS FOR ALL OTHER AREAS ABOVE THE NORMAL POOL ELEVATION AND ARE NOT PART OF THE STRUCTURE & CHANNEL SEEDING. NO MULCH ON THIS AREA.THE PREPARATION FOR THIS AREA SHALL INCLUDE THE GRADING TO A UNIFORM SURFACE OF THE 10:1 SAFETY BENCH AROUND THE PERIMETER OF THE POOL AREA.ONLY THE DISTURBED PORTIONS OF THE BUFFER AREA WILL BE SEEDED AND WILL BE MEASURED FOR FINAL PAYMENT. QUANTITY SHOWN REFLECTS THE AREA WITHIN THE
EASEMENT BOUNDAY.
5 MOBILIZATION/DEMOBILIZATIONTHIS WORK SHALL INCLUDE THE MOBILIZATION AND DEMOBILIZATION OF THE CONTRACTOR'S FORCES AND EQUIPMENT FOR PERFORMING THE WORK UNDER THE CONTRACT. ANY
INSTALLATION OF THE SILT FENCE THROUGH ANY AREA SHALL BE CONSIDERED INCIDENTAL TO THIS ITEM. THE USE OF THE TEMPORARYCONSTRUCTION ACCESS SHALL INCLUDE DEEP TILLAGE OF THE AREA ONCE CONSTRUCTION IS COMPLETE AND IS CONSIDERED INCIDENTAL TO THIS ITEM.
6 DRAINAGE TILE INVESTIGATION AND REMOVALTHIS ITEM WILL CONSIST OF THE EXPLORATORY EXCAVATIONS REQUIRED TO LOCATE AND ABANDON THE TILES SHOWN ON THE PLANS. THIS IS FULL COMPENSATIONFOR THE EXCAVATION, BACKFILLING, ABANDONMENT AND REMOVAL OF THE TILES WITHIN THE PERMANENT EASEMENT BOUNDARY.
7 STEEL SHEET PILESHEET PILING SHALL BE AS DETAILED IN THE PLANS, BENDS AND DEFLECTIONS SHALL BE MADE BY PREFABRICATED PIECES SPECIFICALLY MADE FOR A LOCATION. ANYADDITIONAL LENGTH NECESSARY TO MEET ANGLES, CONSTRUCTION TOLERANCES, ETC. SHALL BE INCIDENTAL TO THE OVERALL CONSTRUCTION. THE TOTAL QUANTITY SHOWN ON SHEET 7.1IS FIGURED AFTER TRIMMING THE SHEET PILE TO MATCH THE SLOPES ON THE SIDES, THE PAID AMOUNT IS THE AREA AFTER TRIMMING TO FINAL ELEVATIONS AND SLOPES.
8 EXCAVATION, EARTH FILLTHIS IS FULL COMPENSATION FOR THE EXCAVATION REQUIRED FOR THE POOL AREA, FOR THE DIKE/BERM (5,640 CY), SUBMERGED BERMS (500 CY),CORE TRENCH (960 CY), OUTLET CHANNEL, STILLING BASIN, BORROW AREA AND OTHER CHANNELS REQUIRED TO OUTLET DRAIN TILES. THIS IS ALSO COMPENSATION TO CONSTRUCTTHE EMBANKMENT BERM (DIKE) INCLUDING THE CLAY CORE TRENCH, STILLING BASIN AND OUTLET CHANNEL TO THE SLOPES AND ELEVATIONS DETAILED ON THE PLANS. THE CONTRACTOR
SHALL PROVIDE FOR A MINIMUM ALLOWABLE SETTLEMENT OF 5% OF THE TOTAL FILL DEPTH WHEN CONSTRUCTING THE BERM. THIS ADDITIONAL QUANTITY OF MATERIAL IS NOT FIGUREDINTO THE BID QUANTITY. EXCESS MATERIAL FROM OTHER EXCAVATIONS CAN BE USED OR WASTED HERE TO BUILD SLOPES OUTSIDE OF THE CORE. THIS QUANTITY ASSUMED A 35%
SHRINKAGE FACTOR ON THE MATERIAL. SEE SHEET 4.0 FOR DETAILS.
9 DRAINFILL, FINETHIS IS FULL COMPENSATION FOR FILL MATERIAL REQUIRED FOR THE WEST AND EAST TOE DRAINS, SEE SHEETS 4.1 AND 4.2 FOR TRENCH DRAIN DETAILS.
10 PERFORATED CORRUGATED POLYETHYLENE TUBING, 6" DIAMETERTHIS IS FULL COMPENSATION FOR PIPE MATERIAL REQUIRED FOR THE WEST AND EAST TOE DRAINS, SEE SHEETS 4.1 AND 4.2 FOR TRENCH DRAIN DETAILS.
11 HDPE, 12" DIAMETER, NON-PERFORATEDTHIS IS FULL COMPENSATION FOR DRAIN TILE OUTLET NO. 1 AND 3, SEE SHEET NO. 6.0 AND 6.2 FOR DETAILS.
12 RCP, 24" DIAMETERTHIS IS FULL COMPENSATION FOR DRAIN TILE OUTLET NO. 2, SEE SHEET 6.1 FOR DETAILS.
13 DRAWDOWN PIPE, CMP, 18" DIAMETER, NON-PERFORATEDTHE ITEM INCLUDES THE COSTS FOR INSTALLATION, BEDDING AND BACKFILLING OF THE CMP OUTLET PIPE TO AND FROM THE WATER CONTROL STRUCTURE.
LENGTH IS BASED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE AND THROUGH BENDS. SEE SHEET NO. 5.0 AND 5.1 FOR DETAILS.
14 INLINE WATER CONTROL STRUCTURE STOP GATE, CMP, 48"THIS ITEM INCLUDES THE MAIN CMP CONTROL STRUCTURE, LID, LOCKING MECHANISM, PVC OR ALUMINUM STOP LOGS, STEPS, CONCRETE FOR BASE, STOP LOG REMOVAL TOOLS, CMPPIPE STUBS, STOP LOG STORAGE TUBE, SLAB AND GRATE, DOWNSTREAM CMP APRON AND ANIMAL GUARD AND THE UPSTREAM CMP PERFORATED INTAKE RISER, GRATE, AND
THE FABRICATION AND INSTALLATION OF THE TWO CMP ANTI-SEEP COLLARS.THE 18" CMP PIPE SHALL BE PAID FOR SEPERATELY UNDER BID ITEM NO. 13. SEE SHEET NO. 5.0, 5.1 AND 5.2 FOR DETAILS.
15 CMP OUTLET PIPE, 12" DIAMETERTHIS IS FULL COMPENSATION FOR OUTLET OF WEST AND EAST TOE DRAINS, SEE SHEET NO. 4.2.
16 CMP OUTLET PIPE, 18" DIAMETERTHIS IS FULL COMPENSATION FOR TILE DRAIN OUTLET NO. 1 AND 2, SEE SHEET NO. 6.0 AND 6.2.
17 CMP OUTLET PIPE, 30" DIAMETERTHIS IS FULL COMPENSATION FOR DRAIN TILE OUTLET NO. 2, SEE SHEET NO. 6.1.
18 RIPRAP, CLASS ETHIS ITEM INCLUDES EXCAVATION, GEOTEXTILE FABRIC PLACEMENT AND RIP RAP MATERIAL AT THE OUTLET CHANNEL FROM THE UPSTREAM SIDE OF THE WEIR WALL TO THE EXISTINGSTRUCTURE AT 390TH STREET, THE EXISTING SLOTTED INTAKE RISER AND ALL TILE OUTLETS AS NOTED.
19 CONCRETE GROUTGROUT MIX SHALL BE AS SPECIFIED AND PLACED AT 5.4 CUBIC FEET OF GROUT PER SQUARE YARD OF RIP RAP AREA FROM 10' UPSTREAM OF WEIR, STILLING BASIN AND SLOPES.
THE GROUT SHALL FULLY ENCASE THE BOTTOM OF THE RIP RAP BUT NOT FILL AROUND THE RIP RAP SO AS TO REDUCE THE ENERGY DISSIPATION CAPABILITIES OF THE RIP RAP.THE GROUT ON THE FIRST 4 FEET ON THE UPSTREAM SIDE OF THE WEIR SHALL BE FINISHED TO A TROWEL SMOOTH FINISH.
ESTIMATE REFERENCE INFORMATIONITEM NO. DESCRIPTION
EXISTING TOPOGRAPHIC SYMBOLS
CONCRETE
GRAVEL/RIP RAP
HATCH PATTERNS
GRADING INFORMATION
952
950
952
950
1:4
BITUMINOUS
F F F F
E E E E
G G G G
XXXXXX
EXISTING PRIVATE UTILITY LINES
STORM SEWER RECTANGULAR CASTING
STORM SEWER CIRCULAR CASTING
STORM SEWER FLARED END / APRON
CURB BOX
FIRE HYDRANT
MANHOLE
WATER REDUCER
WATER BEND
PROPOSED TOPOGRAPHIC SYMBOLS
CLEANOUT
LIFT STATION
RIP RAP
OE OE OE
C C C C
DRAINAGE FLOW
BENCH
BUSH
CATCH BASIN CIRCULAR CASTING
CURB STOP
CATCH BASIN RECTANGULAR CASTING
SIGNAL CONTROL CABINET
CLEAN OUT
DRINKING FOUNTAIN
FLARED END / APRON
FLAG POLE
FUEL PUMP
GRILL
HANDICAP SPACE
HANDHOLE
FIRE HYDRANT
MAILBOX
MANHOLE-HEAT
MANHOLE-ELECTRIC
MANHOLE-GAS
MANHOLE-SANITARY SEWER
MANHOLE-STORM SEWER
MANHOLE-COMMUNICATION
MANHOLE-UTILITY
PEDESTRIAN PUSH BUTTON
PEDESTAL-ELECTRIC
PEDESTAL-COMMUNICATION
VALVE POST INDICATOR
PARKING METER
LIGHT POLE
POLE-UTILITY
POST
PICNIC TABLE
RAILROAD SIGNAL POLE
REGULATION STATION GAS
TREE-DECIDUOUS
SATELLITE DISH
SIGN TRAFFIC
WATER SPIGOT
IRRIGATION SPRINKLER HEAD
IRRIGATION VALVE BOX
TREE STUMP
TELEPHONE BOOTH
TRANSFORMER-ELECTRIC
TREE-DEAD
TRASH CAN
TRAFFIC SIGNAL
VALVE
WETLAND
WELL
TREE-CONIFEROUS
GUY WIRE ANCHOR
LIFT STATION
LIFT STATION CONTROL PANEL
MANHOLE-WATER
BASKETBALL POST
CULVERT END
SOIL BORING
ABBREVIATIONS
A ALGEBRAIC DIFFERENCEADJ ADJUSTALT ALTERNATEB-B BACK TO BACKBIT BITUMINOUSBLDG BUILDINGBMP BEST MANAGEMENT PRACTICEBR BEGIN RADIUSBV BUTTERFLY VALVECB CATCH BASINC&G CURB AND GUTTERCIP CAST IRON PIPECIPP CURED-IN-PLACE PIPECL CENTER LINE
CL. CLASS
CMP CORRUGATED METAL PIPEC.O. CHANGE ORDERCOMM COMMUNICATIONCON CONCRETECSP CORRUGATED STEEL PIPECLVT CULVERTDIA DIAMETERDIP DUCTILE IRON PIPEDWY DRIVEWAYE EXTERNAL CURVE DISTANCEESMT EASEMENTELEC ELECTRICELEV ELEVATIONEOF EMERGENCY OVERFLOWER END RADIUSEX EXISTINGFES FLARED END SECTIONF-F FACE TO FACEFF FINISHED FLOORF&I FURNISH AND INSTALLFM FORCEMAINFO FIBER OPTICF.O. FIELD ORDERGRAN GRANULAR
GRAV GRAVELGU GUTTERGV GATE VALVEHDPE HIGH DENSITY POLYETHYLENEHH HANDHOLEHP HIGH POINTHWL HIGH WATER LEVELHYD HYDRANTI INVERTK CURVE COEFFICIENTL LENGTHLO LOWEST OPENINGLP LOW POINTLT LEFTMH MANHOLEMIN MINIMUMMR MID RADIUSNIC NOT IN CONTRACTNMC NON-METALLIC CONDUITNTS NOT TO SCALENWL NORMAL WATER LEVELOHW ORDINARY HIGH WATER LEVELPC POINT OF CURVEPCC POINT OF COMPOUND CURVEPE PERMANENT EASEMENTPED PEDESTRIAN, PEDESTALPERF PERFORATED PIPEPERM PERMANENTPI POINT OF INTERSECTIONPL PROPERTY LINEPRC POINT OF REVERSE CURVEPT POINT OF TANGENTPVC POLYVINYL CHLORIDE PIPEPVMT PAVEMENTR RADIUSRCP REINFORCED CONCRETE PIPERET RETAININGR/W RIGHT-OF-WAYRSC RIGID STEEL CONDUIT
RT RIGHTSAN SANITARY SEWERSCH SCHEDULESERV SERVICESHLD SHOULDERSTA STATIONSTD STANDARDSTM STORM SEWERTC TOP OF CURBTE TEMPORARY EASEMENTTEMP TEMPORARYTNH TOP NUT HYDRANTTP TOP OF PIPETYP TYPICALVCP VITRIFIED CLAY PIPEVERT VERTICALVPC VERTICAL POINT OF CURVEVPI VERTICAL POINT OF INTERSECTIONVPT VERTICAL POINT OF TANGENTWM WATERMAIN
AC ACRESCF CUBIC FEETCV COMPACTED VOLUMECY CUBIC YARDEA EACHEV EXCAVATED VOLUMELB POUNDLF LINEAR FEETLS LUMP SUMLV LOOSE VOLUMESF SQUARE FEETSV STOCKPILE VOLUMESY SQUARE YARD
UNDERGROUND FIBER OPTICUNDERGROUND ELECTRICUNDERGROUND GASUNDERGROUND COMMUNICATIONOVERHEAD ELECTRICOVERHEAD COMMUNICATIONOVERHEAD UTILITY
953.53
EXISTING CONTOUR MINOREXISTING CONTOUR MAJORPROPOSED CONTOUR MINORPROPOSED CONTOUR MAJORPROPOSED GRADING LIMITS / SLOPE LIMITSPROPOSED SPOT ELEVATIONRISE:RUN (SLOPE)
OC OC OC
OU OU OU
SIG
H
CP
E
PIV
IVB
TRAN
CO
LS
G
E
S
D
U
W
TRASH
C
H
STORM SEWER OUTLET STRUCTURE
STORM SEWER OVERFLOW STRUCTURE
STA:5+67.19980.87
C
TRAFFIC ARM BARRIER
VENT PIPEV
TILE INLET
TILE RISER
SIREN
ORDER MICROPHONE
METERM
ACCESS GRATE
FILL PIPEF
DOWN SPOUT
BIRD FEEDERB
ANTENNA
AIR CONDITION UNITAC
NOTE:EXISTING UTILITY INFORMATION SHOWN ON THIS PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE CONTRACTOR SHALL FIELD VERIFYEXACT LOCATIONS PRIOR TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE LAW. NOTIFY IOWA ONE CALL, 1-800-292-8989 OR WWW.IOWAONECALL.COM.
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS UTILITY LEVEL WASDETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OFEXISTING SUBSURFACE UTILITY DATA"
UTILITIES IDENTIFIED WITH A QUALITY LEVEL OTHER THAN D:
LINE TYPES FOLLOW THE FORMAT: UTILITY TYPE - QUALITY LEVELEXAMPLE: UNDERGROUND GAS, QUALITY LEVEL AUTILITY QUALITY LEVEL (A,B,C,D) DEFINITIONS CAN BE FOUND IN CI/ASCE 38-02.
UTILITY QUALITY LEVELS:
LEVEL D - INFORMATION COMES SOLELY FROM EXISTING UTILITY RECORDS.
LEVEL C - SURVEYING ABOVE GROUND UTILITY FACILITIES, SUCH AS MANHOLES, VALVE BOXES, ETC; AND CORRELATING THIS INFORMATION WITHEXISTING UTILITY RECORDS.
LEVEL B - THE USE OF SURFACE GEOPHYSICAL TECHNIQUES TO DETERMINE THE EXISTENCE AND HORIZONTAL POSITION OF UNDERGROUNDUTILITIES.
LEVEL A - THE USE OF NONDESTRUCTIVE DIGGING EQUIPMENT AT HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES, AS WELLAS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS.
G-A G-A
G
UTILITY MARKER
VALVE VAULT
WW WET WELL
YARD HYDRANT
BARRICADE PERMANENT
TILE OUTLET
|| || || || || ||
> > > > > >
> > > > > > > > > > > >
l l l l l l
l l l l l l l l l l l l
EXISTING UTILITY LINES
l l l l l l l l l l> > > > >
>> >> >> >> >> >> >> >> >> >>
>> >> >> >>
l l l l l ll l l l l l l l l l l l
PROPOSED UTILITY LINES
> > > > >
>> >> >> >> >>
SURVEY SYMBOLS
> > > > > > > > > > > >
BENCH MARK LOCATION
MONUMENT IRON FOUND
CAST IRON MONUMENT
CONTROL POINT
TILE
P
>> >> >> >> >> >> >> >> >> >>
SURVEY LINES
o o o
PAVEMENT MARKING
AUTO SPRINKLER CONNECTION
U
WETLAND DELINEATED MARKER
CONTROLLED ACCESSBOUNDARYCENTERLINEEXISTING EASEMENT LINEPROPOSED EASEMENT LINEEXISTING LOT LINEPROPOSED LOT LINEEXISTING RIGHT-OF-WAYPROPOSED RIGHT-OF-WAYSETBACK LINESECTION LINE
BUSH LINETREE LINEGUARD RAILFENCE-DECORATIVEFENCERETAINING WALL
WATER SERVICEWATERMAINSTORM SEWER DRAIN TILESTORM SEWERSANITARY SERVICESANITARY SEWERFORCEMAIN
PIPE CASINGWATER SERVICEWATERMAINSTORM SEWER DRAIN TILESTORM SEWERSANITARY SERVICESANITARY SEWERFORCEMAIN
WATER TEE
WATER CROSS
WATER SLEEVE
WATER CAP / PLUG
WATER VALVE
EXISTING TOPOGRAPHIC LINES
QUARTER LINESIXTEENTH LINE
TRAFFIC SIGNS
BOLLARD
TEMPORARY EASEMENT
CLVT
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_G01
.2.d
wg
10/2
6/20
18 1
0:38
:33
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
1.2LEGEND
1.2LEGEND
CONTROL POINT#60
ELEV: 1325.13
CONTROL POINT#45
ELEV: 1332.16
1320
1316 13
17 1318 1319 13
21
1322
1320
1320
1320
1320
1320
1320
1317
1318
1318
1319
1319
1319
1319
131913211321
1321
1321
1321
1321
1321
1325
1321
1322
1323
1324
1326
1325
1321
1321
1321
1321
1321
1321
1321
1322
132213
22
1322
1322
1322
1323
1323
1323
1323
1323
1323
1323
1324
1324
132413
24
1324
1324
1324
1325
1330
1323
1324
13261
32713
2813
2913
25
1325
1325
1325
1325
1325
1326
1326
1326
1326
1326
1326
1326
13271328
1328
1328
1328
1328
1330
1335
13271328
1329
1331
1332
1333
1334
1336
1330
1327
1327
1327
1327
1328
1328
1328
1328
1328
1329
1330
1335
1329
1331
1332
1333
1334
1336
1337
1330
1330
1335
1335
1329
1329
1329
1331
1331
1332
1332
1333
1333
1334
1334
1336
1316
1316P
P
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
XX
XX
XX
X
XX OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
X X X
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>
>>
>>>>
>>
>>
>>>>
>>
>>
>>
>>
>>
>>
>> >>
>>
>>
>>
>>
>>
>>
>>
>>
>>
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
2.dw
g 10
/26/
2018
10:
38:4
2 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
2.0EXISTING SITE CONDITIONS
2.0EXISTING SITE CONDITIONSFEETSCALE
0 60 120HORZ.
R
390TH STREET
ROLF
AVE
NU
E
5'x5' TWIN RCBC ROADWAY CULVERTFL ELEV. IN: 1312.4FL ELEV. OUT: 1311.8
NW CORNERSEC. 35, T86N R36W
FOUND PIPE
24" CMP FIELD ENTRANCEFL ELEV. OUT: 1314.4(USE AS CONSTRUCTED)
24" CMP ROADWAYCULVERT
FL ELEV. OUT: 1320.67(USE AS CONSTRUCTED)
6" CONC. T
ILE
DD. N
O. 5
4 - 1
0" C
ON
C. T
ILE
DD. N
O. 5
4 - 1
0" P
LAST
IC T
ILE
10" CLAY TILE
GRAV
EL S
URF
ACE
GRAVEL SURFACE
IOWA STATE UNIVERSITYWATER MONITORING STATION
(RELOCATION BY OTHERS IF NECESSARY)
PERMANENT EASEMENT BOUNDARY
PERMANENT EASEMENT BOUNDARY
3'x6' CMP ARCHROADWAY CULVERT
FL ELEV. OUT: 1322.07
3'x5' RCBCROADWAY CULVERT
FL ELEV. OUT: 1321.76
OWNER:PARTRIDGE, D G & ROSEMARY N
OWNER:PARTRIDGE, D G & ROSEMARY N
OWNER:PARTRIDGE, D G & ROSEMARY N
X
X
X
XX
X
XXXXXXXXXXXXXXXXXXXXXXX
X
X
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
XX
XXXXXXX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
X X X X X X X X X X X X XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
>>
>>
>>
PP
XXXXXXXXXXXXXXXXXXXXXXXXXX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>
>>
>>
>>
>>
>>
>>>>
>>
>>
>> >>
>>
>>
>>
>>
>>
>>
>>
>>
>>
1320
1325
1330
1335
1318
1319
1321
1322
1323
1324
1326
1327
1328
1329
1331
1332
1333
1334
1336
1337
1320
132013201320
1320
1320
1320
1325
1325
1325
1325
1325
1325
1325
1325
1330
1318
1318
1318
1318
1319
1319
1319
1319
1321
1321
1321
1321
1321
1321
1322
1322
1322
1322
1322
1322
1323
1323
1323
1323
1323
1323
1324
1324
1324
1324
1324
1324
1324
1324
1326
13261326
1326
1326
1326
1326
1326
1327
1327
1327
1327
1327
1327
1327
1327
1327
1328
1328
1328
1328
1328
1329
1329
1331
1322
1330
1335
1329
1331
1332
1333
1334
1336
1336
1336 1330
1329
13311332
1316
1316
1316
1317
1317
1317
BORROW AREA
>>>>
>>
>>
24"
RCP
XX
XX
XX
XX
XX
XX
XX
XX
X>>>>
>>
232'
317'
>>
12" HDPE
>>
>>
>>
>>
12" HDPE
1319
1321
>>12" HDPE
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
3.dw
g 10
/26/
2018
10:
38:5
4 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
3.0PROPOSED SITE CONDITIONS
3.0PROPOSED SITE CONDITIONSFEETSCALE
0 60 120HORZ.
R
DESIGN CRITERIA VALUE UNIT REQUIREMENTWATERSHED AREA 520 ACRES Greater than 500 acres
POOL NORMAL WATER LEVEL (NWL) ELEV 1319.50 FTDESIGNED WETLAND POOL AREA (@ NWL) 5.2 ACRESPERCENT POOL AREA TO WATERSHED AREA 1.0 % Range 0.5% to 2% of watershed area
MAXIMUM POOL DEPTH 3.5 FTAVERAGE POOL DEPTH 1.6 FTDEEP WATER AREA (DEPTH > 3 FT) 0.6 ACRESPERCENT DEEP WATER TO POOL AREA 12.0 % Less than 25%
POOL STORAGE VOLUME AT NWL 8.2 ACRE-FTBERM ELEVATION 1324.50 FTPOOL STORAGE VOLUME AT TOP OF DIKE 53.1 ACRE-FTMAXIMUM BERM HEIGHT 1324.5 FTAVERAGE BERM HEIGHT 3.9 FTBERM LENGTH 1100 FTPRIMARY WEIR ELEVATION 1319.50 FTPRIMARY WEIR WIDTH 32 FTAUXILIARY SPILLWAY ELEVATION - FTAUXILIARY SPILLWAY WIDTH - FTAREA OF BUFFER 20.4 ACRESRATIO BUFFER AREA TO NWL POOL AREA 4.0 Less than 4
25-YEAR STORM HWL IN POOL 1322.01 FT25-YEAR PEAK INFLOW 459 CFS25-YEAR PEAK OUTFLOW 409 CFS100-YEAR STORM HWL IN POOL 1322.94 FT100-YEAR PEAK INFLOW 730 CFS100-YEAR PEAK OUTFLOW 653 CFS
WETLAND ELEV INCREMENTAL CUMULATIVE CUMULATIVEPOOL DEPTH AREA VOLUME VOLUME
(FT) (FT) (FT2) (FT3) (AC-FT)0.0 1316.0 8,100 0.001.0 1317.0 44,008 26054 0.602.0 1318.0 118,412 107264 2.463.0 1319.0 185,189 259064 5.953.5 1319.5 214,169 358904 8.244.0 1320.0 242,429 473053 10.864.5 1320.5 270,434 601269 13.805.0 1321.0 305,596 745277 17.115.5 1321.5 381,210 916978 21.056.0 1322.0 404,010 1113283 25.566.5 1322.5 432,014 1322289 30.367.0 1323.0 463,575 1546186 35.507.5 1323.5 495,201 1785880 41.008.0 1324.0 527,272 2041499 46.878.5 1324.5 560,587 2313463 53.11
>> TILE RELOCATE>>
TILE APPROXIMATE TILE LOCATIONS
POOL NORMAL WATER LEVEL
100-YEAR STORM HWL AREA
AREA > 3-FT DEPTH
PERMANENT EASEMENT BOUNDARY
REMOVE EXISTING TILEXXXXXXXXX
GRADING NOTES:
1. REMOVE ALL TREES AND BRUSH THAT MAY LIE BELOW THE NORMAL POOL ELEVATION 1319.50.2. ALL EXISTING FIELD TILE SHALL BE OBLITERATED WITHIN THE BERM STRUCTURE , SEE SHEET 2.0 & 3.0 FOR
LOCATIONS, OTHER AREAS CAN BE ABANDONED IN PLACE. NEW TILE OUTLETS WILL BE INSTALLED (SEEDETAILS).
3. TOPSOIL STRIPPING (SPEC SECT IA-1) AND SITE GRADING (SPEC SECT IA-21) SHALL CONSIST OF ALL GRADINGINSIDE OF POOL AREA, EXCLUDING THE BERM AND CLAY BORROW AREAS. CLAY ENCOUNTERED IN POOLAREA SHALL BE USED IN CLAY CORE AREA. ALL OTHER EXCESS TOPSOIL FROM POOL AREA SHALL BESTOCKPILED DURING CLAY CORE CONSTRUCTION, USED IN BERM CONSTRUCTION OUTSIDE OF CLAY CORE,OR SPREAD IN DESIGNATED WASTE AREA.
4. CLAY MATERIAL EXCAVATED FROM CLAY BORROW AREA SHALL BE USED IN CLAY CORE CONSTRUCTION. ALLEXCESS CLAY SHALL BE USED IN CONSTRUCTION OF BERM OUTSIDE OF CLAY CORE. FILL USED FOR CLAY COREAND BERM CONSTRUCTION IS INCLUDED AS EARTHFILL (SPEC SECT IA-23).
5. SPREAD 6" OF TOPSOIL IN PRIMARY CLAY BORROW AREA AND BERM AREA AFTER CONSTRUCTIONACCORDING TO SPEC SECT IA-26. TOPSOIL IS NOT REQUIRED ON ANY PORTIONS OF SITE BELOW ELEVATION1316.5.
6. STRIP AND SALVAGE 12" OF TOPSOIL FROM BORROW AREAS. AFTER BORROW OPERATIONS ARE COMPLETEDSPREAD TOPSOIL UNIFORMLY OVER THE BORROW AREA (INCLUDING AREAS BELOW THE WETLAND NORMALPOOL ELEVATION BUT NOT SLOPES OF DEEP POOL AREA (BELOW 1316.5).
7. STRIPPED AND REMOVED UNSUITABLE MATERIALS, IF ANY, ARE TO BE DISPOSED OF IN DESIGNATED AREASAS DIRECTED BY ENGINEER AND PRIOR TO TOPSOIL PLACEMENT.
8. IN TOPSOIL WASTE AREAS, FEATHER TOPSOIL INTO SLOPE SO THAT OVERLAND FLOW IS NOT IMPEDED.9. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS, CODES, AND
OSHA STANDARDS.10. CONTRACTOR SHALL CONTACT IOWA ONE CALL @ 1-800-292-8989 FOR LOCATION OF ALL UTILITIES AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION AS REQUIRED BY STATE LAW.
ARMOR STILLING BASIN AND SLOPES WITH RIPRAP & GROUT, 483 TN (SEE DETAILS)
390TH ST.
ROLF
AVE
.
POOL NORMAL WATER LEVEL ELEV: 1319.5
100 YR STORM HIGH WATER LEVELELEV: 1322.94
SILT SEDIMENT BASINS(20' WIDE BOTTOM BY100' LENGTH AT 3:1SLOPES)
WATER CONTROL STRUCTUREAND STOP LOG STORAGE
DRAIN TILE OUTLET NO. 3,12" HDPE (SEE SHT NO. 6.3)
DRAIN TILE OUTLETNO. 1, 12" HDPE(SEE SHT NO. 6.0)
RELAY EXISTING TILEWITH 12" HDPE(SEE SHT. 6.2)
DRAIN TILE OUTLET NO. 2INSTALL NEW 24" RCP TILEFOR NEW DD. 54 OUTLET,(SEE SHT NO. 6.1)
TOE DRAIN (TYP.) SEE DETAILS
EASEMENT BOUNDARY
EASEMENT BOUNDARY
EXIST. 6"CONC. TILE
3'x6' CMPARCH
ROADWAYCULVERTFL ELEV.
OUT:1322.07
3'x5' RCBCROADWAY
CULVERT FLELEV. OUT:
1321.76
EXIST. DD 5410" CONC. TILE
EXIST. DD 5410" PLASTIC TILE EXIST. 10" CLAY TILE
SUBMERGED BERM'S, TOPBERM ELEV: 1319.0, 5' TOPW/3:1 SLOPES
TOE DRAIN (TYP.) SEE DETAILS
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1324
.30
1324
.3
0+00
1324
.76
1324
.8
1324
.90
1324
.8
0+50
1324
.62
1324
.5
1324
.50
1324
.2
1+00
1324
.50
1323
.7
1324
.50
1323
.3
1+50
1324
.50
1323
.2
1324
.50
1323
.2
2+00
1324
.50
1323
.1
1324
.50
1322
.4
2+50
1324
.50
1321
.3
1324
.50
1320
.1
3+00
1324
.50
1319
.0
1324
.50
1317
.9
3+50
1324
.50
1317
.2
1324
.50
1316
.4
4+00
1324
.50
1316
.0
1324
.50
1315
.74+50
1324
.50
1315
.5
1319
.50
1315
.6
5+00
1319
.50
1315
.9
1324
.50
1316
.6
5+50
1324
.50
1317
.7
1324
.50
1318
.8
6+00
1324
.50
1319
.7
1324
.50
1320
.4
6+50
1324
.50
1320
.9
1324
.50
1321
.2
7+00
1324
.50
1321
.2
1324
.50
1321
.2
7+50
86.8'
62'
32'
STA: 0+75.72ELEV: 1324.50BEGIN DIKE CONSTRUCTION
STA: 5+10.48ELEV: 1311.70
CL OF WEIR
STA: 2+81.00ELEV: 1321.00BEGIN CORE TRENCH
STA: 6+81.85ELEV: 1321.00
END CORE TRENCH
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
>>
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
X
X
X
X
X
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>
>>>>
>> >>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
1+00
2+00
3+00
4+00
5+00
6+00
7+00
>>
>> >>
>>
-1:3.
0
-1:3.
0
1319
1318
1317
1316
13201321 1322
1324
1324
13231322
13211320
1319
1318
1317
1317 1318
1319
1320 1321
1322 1324
1324
1323 1322
1321
13201319
13171316
1317
1316
1317
13181319
1320
1321
1322
1323
1324
1325
1316
1317
1318
1319
1320
132113
22
1323 1316
1317
1318
1319
1320
1320
1319
1318
13171316
1315
1320
1321
1319
1330
1324
1324
>>
>>
>>
>>
>> >> >>>>
>>>>
>>
>>
>>
>>
>>
12" HDPE
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
4.dw
g 10
/26/
2018
10:
39:0
3 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
R
TOP CORE TRENCH ELEV: 1321.0NWL ELEV:
1319.5
STILLING BASIN ELEV: 1311.7
TOP DIKE/BERM ELEV: 1324.5
TOP CORE TRENCH ELEV: 1321.0
WATER CONTROL STRUCTUREAND STOP LOG STORAGE
(SEE DETAILS SHT NO. 5.2)
4.0BERM PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
SEE TYPICAL SECTION OF BERMEMBANKMENT. (SHT. NO. 4.1)
CORE TRENCH (TYP.)
TOE DRAINS (TYP.) SEE DETAILS
TOE DRAIN (TYP.)SEE PLAN ANDPROFILE SHT. 4.2
CL OF DIKE/BERMELEV: 1324.5
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X XX
XX
X
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
EXISTING GRND
EXISTING GRND ELEV. PROPOSED DIKE/BERM ELEV.
ROLF
AVE.
390TH ST.
EXISTING TWIN 5'x5' RCBC(USE AS CONSTRUCTED)
STEEL SHEET PILE WEIR32 LF FACE (SEE DETAILS)
TOE DRAIN (TYP.)SEE PLAN ANDPROFILE SHT. 4.2
SEE CORE TRENCH AND CONSTRUCTIONNOTES ON SHT. NO. 4.1
1:31:3
1:3
1:3
>> >>
EXISTING MAIN CONTOUREXISTING INTERMEDIATE CONTOUREXISTING FIELD DRAIN TILEPROPOSED MAIN CONTOURPROPOSED INTERMEDIATE CONTOURPROPOSED GROUTED RIPRAPPROPOSED SHEET PILE WEIR
PROPOSED OUTLET PIPE
LEGEND
REMOVE EXISTING TILETHROUGH DIKE/BERM
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1324
.50
1321
.2
7+50
1324
.50
1321
.1
1324
.50
1321
.0
8+00
1324
.50
1321
.0
1324
.50
1321
.1
8+50
1324
.50
1321
.1
1324
.50
1321
.3
9+00
1324
.50
1321
.4
1324
.50
1321
.5
9+50
1324
.50
1321
.7
1324
.50
1321
.9
10+00
1324
.50
1322
.1
1324
.50
1322
.4
10+50
1324
.50
1322
.7
1324
.50
1323
.1
11+00
1324
.50
1323
.6
1324
.50
1323
.9
11+50
1324
.50
1324
.5
1325
.05
1325
.112+00
1325
.62
1325
.6
1326
.15
1326
.1
12+50
STA: 11+75.00ELEV: 1324.50END DIKE CONSTRUCTION
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
8+00
9+00
10+0
0
11+0
0
12+0
0
12+5
0
1321
1322 13
23 1324 13
25
1326
13211322
1322 1323 1324 1325 1326 13271328
13221324 1323
13241323 13221321
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
4.dw
g 10
/26/
2018
10:
39:0
6 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
R
4.1BERM PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
TOP OF DIKE/BERM ELEV: 1324.5
EXISTING GRND
EXISTING GRND ELEV. PROPOSED DIKE/BERM ELEV.
390TH ST.
METAL SHEET PILING
24' DOWNSTREAM (TYP.)
18" MIN.
±3'
1'3"
COMPACTEDEARTH
BACKFILL
6" PERFORATEDCORRUGATEDPOLYETHYLENEDRAINAGE TUBING
TOE DRAIN DETAILNOT TO SCALE
POROUS BACKFILL
EXISTING1
UPSTREAM10'
APPROX 1' SUBCUT
1
SURFACE
ELEV=1324.5DOWNSTREAM
TYPICAL X-SECTION OF EMBANKMENT
1
33
MIN 4'1
MIN 8'
CORE TRENCH
MIN 8'
8.0'
ELEV=1321.0
GROUND
10'ACCESSBENCH NWL
ELEV 1319.5
CONSTRUCTION NOTES:
1. PLACE NONWOVEN GEOTEXTILE FABRIC UNDERALL RIPRAP
2. RIPRAP SHALL BE 18" DEEP UNLESS OTHERWISENOTED OR APPROVED BY ENGINEER
3. TOP OF RIPRAP UPSTREAM OF WEIR SHALL BE AMINIMUM OF 0.2' BELOW TOP OF WEIR
4. 4' OF RIPRAP UPSTREAM OF WEIR SHALL BEGROUTED TO A SMOOTH TROWEL FINISH.
5. THE CONTRACTOR SHALL PROVIDE A MINIMUMALLOWABLE SETTLEMENT OF 5% OF THE TOTALFILL DEPTH ON THE BERM
CORE TRENCH NOTES:
1. SUITABLE MATERIAL FOR EMBANKMENTCONSTRUCTION SHALL BE OBTAINED FROM THESPILLWAY EXCAVATIONS AND DESIGNATEDBORROW AREAS.
2. STRIP ALL ORGANICS AND TOPSOIL BENEATHEMBANKMENT.
3. EXCAVATE MINIMUM OF 4 FT DEPTH CORETRENCH (SEE DETAIL) OR UNTIL SUITABLEMATERIAL IS REACHED.
4. CONSTRUCT CORE TRENCH ALONG APPROXIMATECENTERLINE OF FILL.
5. EXTEND CORE INTO AND UP SIDES SLOPES TO 1.5'ABOVE NORMAL POOL ELEVATION.
6. SIDES SLOPES SHALL NOT BE STEEPER THAN 1:1.7. FILL SHALL BE PLACED IN MAXIMUM 9" LIFTS
PRIOR TO COMPACTION.8. BACKFILL WITH LOW PERMEABLE MATERIAL
FROM THE PRIMARY BORROW AREA.9. THE MAXIMUM THICKNESS OF EACH LAYER OF
FILL BEFORE COMPACTION SHALL BE ASSPECIFIED. THE ENTIRE SURFACE LAYER OF FILLSHALL BE COMPACTED BY AT LEAST 2 PASSES OFTHE COMPACTION EQUIPMENT.
>> >>
EXISTING MAIN CONTOUREXISTING INTERMEDIATE CONTOUREXISTING FIELD DRAIN TILEPROPOSED MAIN CONTOURPROPOSED INTERMEDIATE CONTOURPROPOSED GROUTED RIPRAPPROPOSED SHEET PILE WEIR
PROPOSED OUTLET PIPE
LEGEND
CL OF DIKE/BERMELEV: 1324.5
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1321
.2
0+00
1317
.37
1320
.2
1316
.67
1319
.3
1315
.97
1318
.3
1315
.70
1317
.6
1+00
1315
.58
1316
.8
1315
.45
1316
.0
1+50
1315
.33
1315
.7
1315
.20
1315
.5
2+00
1314
.35
1315
.1
1315
.6
2+50
1316
.2
1316
.8
3+00
1317
.9
1318
.8
3+50 4+00
1321
.2
0+00
1320
.2
1319
.3
1318
.3
1317
.6
1+00
1316
.8
1316
.0
1+50
1315
.7
1315
.5
2+0013
15.1
1315
.6
2+50
1314
.80
1316
.2
1315
.25
1316
.8
3+00
1315
.37
1317
.9
1315
.50
1318
.8
3+50 4+00
70' - 6" HDPE @ 2.81%70' 6" HDPE@ 2.81%
91' - 6" HDPE @ 0.50%91' 6" HDPE@ 0.50%
35'6" HDPE@ 0.50%
6'6" HDPE@ 4.53%
9'6" HDPE
@ 4.01%
75' - 6" HDPE @ 0.50%75'
6" HDPE@ 0.50%
STA: 2+55.12FL ELEV: 1314.0012" CMP OUTLET
STA: 2+84.23FL ELEV: 1315.17GRADE BREAK
STA: 3+58.75FL ELEV: 1315.54
STA: 2+32.66FL ELEV: 1314.0012" CMP OUTLET
STA: 2+06.84FL ELEV: 1315.17
GRADE BREAK
STA: 0+81.22FL ELEV: 1315.80GRADE BREAK
STA: 0+11.60FL ELEV: 1317.75
20' - 12" CMP@ 4.53%
20' - 12" CMP@ 4.01%
PP
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
>>
OEOE
OEOE
OE
OEOE
OE
OEOE
OEOE
OE
OEOE
OEOE
OEOE
OEOE
OEOE
OEOE
OEOE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
XX
XX
X
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>> >> >>
0+00
1+00
2+00
3+00
3+58
.75
>>
>>
>>>>-1
:3.0
-1:3
.0
131913181317
13161320 1321 1322 1324
1324
1323 1322
1321 13201319
1318 1317
131713181319
1320 13211322
1324
13241323 132213211320 1319
1317 13161317
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1316
1317
1318
1316
1317
1318
1319
1320
1320
13191318
1317
1316
1315
1320
1321
1319
1324
1324
1321
1322
13211321
13201319
>>>>
>>>>
6" HDPE>>
>>>>
>> >> >>>>
>>6" HDPE
6" HDPE
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
4.dw
g 10
/26/
2018
10:
39:1
2 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
4.2BERM TOE DRAIN PLAN AND PROFILE
4.2BERM TOE DRAIN PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
CL DIKE/BERM
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
PERFORATED TOEDRAIN (EAST SIDE)
PERFORATED TOEDRAIN (WEST SIDE)
390TH ST.
ROLF
AVE
.WATER CONTROLSTRUCTURE AND STOPLOG STORAGE
CMP SLOTTEDINTAKE RISER
PROPOSED DIKE/BERM EMBANKMENTEXISTING GROUND
STILLING BASIN ELEV: 1311.7
R
EXISTING GRND ELEV. PROPOSED PIPE FLOWLINE
STEEL SHEET PILE WEIR,32 LF FACE (SEE DETAILS)
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
-0+50
1316
.50
1316
.0
0+00
1316
.37
1315
.9
1316
.24
1315
.9
0+50
1316
.10
1315
.7
1315
.97
1315
.6
1+0013
15.6
1+50 2+00
I=1316.50 18" NE
0+00.0-0.0'R=1319.50
CMP SLOTTED INTAKE RISER
0.5' SUMPSUMP EL=1316.00
I=1316.28 18" SWI=1316.28 18" NE
0+42.3-0.0'R=1323.00
WATER CONTROL STRUCTURE
0.0' SUMPSUMP EL=1316.28
42'18" CMP@ 0.53%
28'18" CMP@ 0.53%
50'18" CMP@ 0.53%
STA: 1+19.93FL ELEV: 1315.8718" CMP OUTLET
ELEV: 1324.50TOP OF DIKE/BERM
STA: 1+36.84ELEV: 1311.70STILLING BASIN
NWL: 1319.5
STOP LOG STORAGE STRUCTURE
ANTI-SEEP COLLARS, SPACE 10' APART10'
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
>>
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
X
X
X
X
X
X
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>
>>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>> >>
>>
WATER CONTROL STRUCTURESTOP LOG STORAGE
CMP SLOTTED INTAKE RISERW/22 TON RIP RAP
18" CMP
18" CMP
18" CMP
>>
>>
>>
>>
6" HDPE
>>>> >> >>
>>>>
>>
>>
6" HDPE
1320
1316
1317
1318
1319
1315
1320
1325
1316
1317
13181319
1321
1322
1323
1324
1330
1315
1320
1320
13241324
1320
1317
1320
1316
1319
13191320
1324
1324 1320 1316
1312
1312
0+001+
00
1+36
.84
>>
>>
>>
12" HDPE
R
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
5.dw
g 10
/26/
2018
10:
39:2
2 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
5.0WATER CONTROL STRUCTURE, OUTLET PIPE PLAN AND PROFILE
5.0WATER CONTROL STRUCTURE, OUTLET PIPE PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
390TH ST.ROLF
AVE
.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
EXISTING GRND
EXISTING GRND ELEV. PROPOSED PIPE FLOWLINE ELEV.
TOE DRAIN (TYP.)
TOE DRAIN (TYP.)
EXISTING TWIN 5'x5' RCBC ROAD CROSSING
STEEL SHEET PILE WEIR(SEE DETAILS)
PROPOSED 18"CMP OUTLET
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
5.dw
g 10
/26/
2018
10:
39:2
5 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
5.1SLOTTED INTAKE RISER AND OUTLET PIPE DETAILS
5.1SLOTTED INTAKE RISER AND OUTLET PIPE DETAILS
BEEHIVE INLET GRATE
SECTION VIEW
NOT TO SCALE
PLAN VIEWNOTE:NUMBER OF RODS AND SIZEOF GRATE VARY W/ SIZE OFTILE INTAKES PAINT WITH (2)COATS RUST INHIBITING PAINTFOLLOWING FABRICATION
(STEEL BARS)
NOTES:1. BEGIN BACKFILL IMMEDIATELY AFTER PIPE HAS BEEN PLACED2. EXCAVATE 3" BELOW PIPE GRADE. THEN BACKFILL WITH DAMP
FRIABLE SOIL FREE FROM LUMPS AND RAKED OR GRADED TOA TRUE PLANE BEFORE PLACING CMP. NO COMPACTION OFBEDDING IS REQUIRED.
3. USE COMPACTED CLAY MATERIAL FOR PIPE BEDDINGUPSTREAM OF PIPE DIAPHRAGM.
4. PIPE BEDDING MATERIAL SHALL BE HAND TAMPED ONLY.POWER TAMPING IS NOT ALLOWED.
3"
CMP PIPE BEDDING FOR WATER
NOT TO SCALE
COMPACTEDBACKFILLAS SPECIFIED
DIACOMPACTED CLAY
MATERIAL
CONTROL STRUCTURE
A
ACONTINUOUS WELDBETWEEN BANDAND COLLAR.
CONTINUOUS WELDBETWEEN BANDAND COLLAR.
TOP OF BAND
BOTTOM OF BAND
BOTTOM OF COLLAR
CORRUGATED METALSHEET WELDED TOCENTER OF BAND.
CMP ANTI-SEEP COLLARNOT TO SCALE
(SOURCE: SUDAS 9040.117)
SLOTTED HOLES@ 8" O.C.
1/2" X 2" SLOTTED HOLESFOR 3/8" DIA BOLTS
BAND
6'
3'
2"2"
12"
3'BAND
SECTION A-A
NWL 1319.5
CMP SLOTTED INTAKE RISERNOT TO SCALE
PIPE TOWATER CONTROLSTRUCTURE
CORRUGATED METALRISER W/ PERFORATIONS
WELDED COUPLERWITH THREADED BANDS
BEEHIVE INLETGRATE (SEE DETAIL)
18" D
IA
C.M
. PIP
E
24" DIA
C.M. PIPE
BERM SLOPE
SLOTTED PERFORATIONS2" X 6" SLOTS SPACED 8"
HORIZ. & 6" VERT. OFFSETCOLUMNS 4" AND 8" FROM
TOP OF STRUCTURE
SURROUND RISERWITH RIP RAP
INV =1316.5
SEAM
TOP VIEW
30° TYPICAL
C SLOTL
WELDED COUPLERWITH THREADED BANDS
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
5.dw
g 10
/26/
2018
10:
39:3
0 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
5.2WATER CONTROL AND STOP LOG STRUCTURE DETAILS
5.2WATER CONTROL AND STOP LOG STRUCTURE DETAILS
COVER/STOP LOG STORAGE NOTES:
1. BOTH PADLOCKS FOR ACCESS COVER AND STOP LOG STORAGE TUBE SHALL BE KEYED ALIKE. FOUR KEYSARE TO BE SUPPLIED UPON PROJECT COMPLETION.
2. PROVIDE 24" GRATE AND COLLAR (AGRI DRAIN GR24 GRATE AND GRC24 COLLAR OR APPROVED EQUAL)FOR STOP LOG STORAGE.
3. STOP LOGS ARE TO BE PLACED AFTER SEEDING IS COMPLETE TO AN ELEVATION 1.5 FEET BELOWNORMAL POOL ELEVATION.
4. STOP LOGS NOT USED ARE TO BE PLACED IN THE STOP LOG STORAGE UNIT.
FURNISH & INSTALL2"X6" ALUMINUN STOP LOGSAND REMOVAL TOOLS.STOP LOGS ARE TO BE FINISHEDCUT 1" SHORTER THAN OPENINGIN FIELD TO FIT THE FABRICATEDSTOP LOG CHANNEL.
STOP LOG CHANNEL NOTES:
1. ALL STEEL SHALL BE FY=36 KSI.
2. ANCHORS SHALL BE STAINLESS STEEL FURNISHED W/ STAINLESS STEEL NUTS, WASHERS ANDLOCK WASHERS.
3. STOP LOG CHANNEL SHALL BE FURNISHED AS ONE CONTINUOUS PIECE W/CONTINUOUS WELDS.
4. ALL STEEL STOP LOG CHANNEL COMPONENTS ARE TO BE GALVANIZED AFTER WELDING ANDDRILLING IS COMPLETE.
5. CONTRACTOR IS TO APPLY SEALANT VERY GENEROUSLY TO BACKSIDE OF STOP LOG CHANNEL TOENSURE WATERTIGHT SEAL TO STRUCTURE. SEALANT SHALL BE SIKA 30 YEAR INDUSTRIAL CAULKIN LIMESTONE GREY OR APPROVED EQUIVALENT.
WATER CONTROL STRUCTURE NOTES:
1. STRUCTURE SHOP DRAWINGS ARE REQUIRED FOR ENGINEER'S REVIEW AND APPROVAL BEFOREFABRICATION OF WATER CONTROL STRUCTURE.
2. STOP LOG CHANNEL IS TO BE ANCHORED TO THE WALLS AND FLOOR PRIOR TO PLACING CONCRETEINVERT.
3. A CONCRETE INVERT IS TO BE INSTALLED AFTER STOP LOG CHANNEL IS INSTALLED. THE BOTTOMSTOP LOG IS TO BE CAST INTO THE INVERT WITH THREE HALF INCH DIA. "J BOLTS" FASTENED TOTHE BOTTOM STOP LOG. NO LIFTING HOLES ARE REQUIRED FOR THIS BOTTOM LOG.
4. ALL SECTIONS OF THE STRUCTURE ARE TO HAVE MASTIC APPLIED TO THE JOINTS..
5. PLACE BASE OF STRUCTURE ON FIRM UNDISTURBED EARTH FOUNDATION APPROVED BY ENGINEER.
6. MANHOLE STEPS ARE TO BE INSTALLED FOR MAINTENANCE ACCESS TO THE STOP LOGS.
NOT TO SCALE
STOP LOG & REMOVAL TOOLDETAIL
10'-6
"
2"X6" ALUM TUBE WITH3/16" WALL THICKNESSIS REQUIRED
6"
1 1/2" 1/2"
1"
BEND 6" LOOPAND WELD TOPROVIDE HANDLE
1/2" ROUNDSTEEL ROD
TWO REMOVAL TOOLS REQUIRED,MUST BE USABLE WITH TYPE OFSTOP LOG PROVIDED
SUPPLY 1 1/4" DIA X 1/4"THICK 'WASHER' WELDEDTO 1/2" STEEL ROD
LOCKING BAR2"X2"X1/4" ANGLE 36" LONGINSTALL 1/2" BOLT W/WELDEDNUT AS HINGE AT ONE END.DRILL 1/2" HOLE FOR PADLOCKAT OTHER END.
6"X1/2" EYEBOLT CASTINTO SLAB FOR HINGE
36"X36"X4" CONCRETESLAB FLUSH WITHGROUND W/ GRC24PCOLLAR CAST INTO SLAB
4.5 LF 24" DIA DUAL WALLHDPE BURIED FOR STOPLOG STORAGE TUBE
NOT TO SCALE
COVER AND STOP LOGSTORAGE DETAIL
24" GRATE AND COLLAR(LOCATION AS SHOWNON PLANS)
PLACE 8" COMPACTEDROCK TO SUPPORT TUBEAND PROVIDE DRAINAGE
ALTERNATE STOP LOG MATERIAL1 1/2" X 6" PVC STOP LOGS.STOP LOGS CAN BEPREFABRICATED TO FIT THESTOP LOG CHANNEL.
PROVIDE OPENINGS IN COVERON BOTH SIDES FOR PLATE
TO PROJECT THROUGH
STOP LOGS
C CONDUITL
DIAM = RISER I.D. + 4
LOCKING RODSEE DETAIL
PADLOCK
2" OVERHANG
COVER TO BE MADE OF C.M.METAL THICKNESS = 0.138"WITH CORRUGATIONSRUNNING PARALLEL TO CONDUIT
PLAN VIEW FOR COVER PVC STOP LOGS
1 12"X 6"REMOVABLE
STOP LOGS
HOLD OPENFRAME INPLACE
OF STOP LOG
LOCKABLE LID
C.M. RISER48" DIAM.
18" D
IAC.
M. P
IPE
18" D
IAC.
M. P
IPE
8" POUREDCONC. BASE
4' MIN4' MIN
18" CRCS CMPSTUB (TYP)
18" CRCS CMPSTUB (TYP)
ONE CORRUGATION
CHANNEL - 2 REQUIREDWELD TO RISER
7.0
FEET
DETAIL A
SECTION ON CENTERLINE OF RISER(STOP LOGS AND COVER NOT SHOWN)
3"5"
3"
7/8"
1 34"
3/4"
2 12"
RISER TOP
DETAIL A
3" X 8" X 1 4" THICKGALVNIZED STEELPLATES WELDED TORISER (2 REQUIRED)
DRAWDOWN INLET RISER DETAIL
ELEV= 1316±
ELEV=1316 +/-
ELEV= 1319.5
ELEV= 1322.0
BOTTOM OF STRUCTURE
NORMAL POOL
ELEV= 1322.0
ELEV= 1323.0
INV= 1316.28INV= 1316.28
NOT TO SCALE
NOT TO SCALE
C.M. RISER48" DIAM.
1'
STEPS
STEPS
FLOW
PROVIDE AT MINIMUM 4" OFTHE CORRUGATED RISERENCASED IN THE 8" POUREDCONCRETE BASE.
1300
1305
1310
1315
1320
1325
1330
1335
1340
1345
1300
1305
1310
1315
1320
1325
1330
1335
1340
1345
1317
.4
0+00
1318
.0
1319
.1
0+50
1320
.4
1320
.70
1321
.7
1+00
1320
.92
1323
.1
1321
.14
1324
.4
1+50
1321
.35
1325
.8
1327
.8
2+00
VPI:
1+00
.00
EL: 1
320.
70
VPI:
1+76
.82
EL: 1
321.
37
25' - 12" HDPE@ 0.87%
20'18" CMP@ 0.87%
INTERCEPT EXISTING 6"CONC. TILE AND RELAY
NEW 12" HDPE TOPOOL. REMOVE
EXISTING TILEDOWNSTREAM
NWL: 1319.5
TOP OF DIKE/BERM ELEV: 1324.5
CL R
OLF
AVE
.
EXISTING GROUND
57' - 12" HDPE@ 0.87%
XX
XX
XX
XX
XX
XX
XX
X
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>>>
>>>>
>>>>
>>
>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
2
3
4
5
0+00
1+00
2+00 2+
17.8
4
>>>>
>>
12" HDPE
1320
1325
1317
1318
1319
1321
1322
1323
1324
1324 13
24
1326
R
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
6.dw
g 10
/26/
2018
10:
39:4
2 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
6.0DRAIN TILE NO. 1 OUTLET PLAN AND PROFILE
6.0DRAIN TILE NO. 1 OUTLET PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
RIP RAP BELOW TILEOUTLET (18 TON)
NORMAL POOLELEV. 1319.5
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
REMOVE EXISTINGTILE DOWNSTREAM 6"
EXIST
. CONC. T
ILE
RIP RAP BELOW TILEOUTLET 1.5' DEEP (18 TON)
ROLF
AVE
.
EXISTING GRND ELEV. PROPOSED PIPE FLOWLINE ELEV.
PERMANENT EASEMENT
CONSTRUCTION NOTES:1. TILE INSTALLATION THAT OCCURS OUTSIDE THE LIMITS OF THE
PERMANENT EASEMENT, CONTRACTOR SHALL MINIMIZE DISTURBEDAREA AND RESTORE TO PRE-CONSTRUCTION CONDITION.
2. CONNECT TO EXISTING TILE AS DETAILED, FITTINGS ARE INCIDENTAL.3. EXISTING TILE LINES TO BE ABANDONED WITH CONCRETE PLUG OR
END CAP.4. FIELD VERIFY ALL TILE LOCATIONS, SIZES, AND DOWNSTREAM INVERT
ELEVATIONS.5. END OF DRAIN TILE SHALL BE CUT OFF AND PLUGGED WHEN
EXPOSED FROM EXCAVATION OF WETLAND POOL.6. IF DRAIN TILE IS NOT EXPOSED FROM EXCAVATION, MATCH EXISTING
TILE SIZE AND RELAY NEW TILE AT A MINIMUM 0.10% SLOPE.7. ALL PROPOSED TILE ENDS SHALL BE MINIMUM 1 FOOT ABOVE
WETLAND POOL ELEVATION 1319.5'.8. ARMOR DOWNSTREAM END OF DRAIN TILE WITH CLASS 'E' RIP RAP.9. FURNISH AND INSTALL RODENT GUARD AT PROPOSED TILE END.
NOT TO SCALE
CIRCUMFERENTIAL WRAP OF 30" WIDE MIN.GEOTEXTILE FABRIC CENTERED ON JOINT ANDOVERLAP A MIN. OF 12"
2dMATCH INVERTS
NEW TILE SHALL BEOF EQUAL SIZE OR THE NEXT
LARGER SIZE PIPE
CONCRETE COLLAR OF 3,000 PSIMIN. STRENGTH CONCRETE, MIN. 2d WIDECENTERED ON JOINT, MIN. 6" THICKNESSFOR FULL 2d WIDTH. THICKNESS CANTAPER DOWN BEYOND TO THE 2d WIDTH.
VERIFY THE ELEVATION OF THE EXISTINGTILE INLETS AND DIRECTION OF FLOW
PROFILE VIEW
d
FIELD TILEREPAIR CONNECTION
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
1300
1305
1310
1315
1320
1325
1330
1335
1340
1345
1300
1305
1310
1315
1320
1325
1330
1335
1340
1345
1317
.9
0+00
1318
.5
1319
.6
0+50
1320
.55
1320
.8
1320
.59
1321
.3
1+00
1320
.64
1322
.0
1320
.68
1322
.9
1+50
1320
.73
1323
.7
1320
.77
1324
.4
2+00
1320
.82
1325
.1
1320
.86
1325
.0
2+50
1320
.90
1325
.0
1320
.95
1325
.2
3+00
1320
.99
1325
.9
1321
.04
1326
.1
3+50
1321
.08
1326
.1
1321
.13
1325
.9
4+00
1321
.17
1325
.8
1321
.22
1325
.84+50
1321
.26
1325
.9
1321
.31
1326
.0
5+00
1321
.35
1326
.1
1321
.40
1326
.2
5+50
1321
.44
1326
.3
1321
.48
1326
.5
6+00
1321
.53
1326
.7
1326
.8
6+50
1327
.0
1327
.2
7+00 7+50
VPI:
0+70
.43
EL: 1
320.
54
VPI:
6+47
.79
EL: 1
321.
57
560' - 24" RCP @ 0.18%131' 24" RCP@ 0.18%
EXISTING 10" PE TILE (DD. 54)
STA: 3+35.97ELEV: 1326.19END FILL OVER NEW 24" RCP20' - 30" CMP
@ 0.18%
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
XX
XX
XX
XX
XX
XX
OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE
>>>>>>>>>>>>>>>>>>
>>>>
>>>>
>>>>
>>>>
>>>>>>>>>>>>>>>>>>>>>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>>>>>>>>>>>>>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>>>>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>>
>>
>>
>>
>>
>>
>>
>>
1325
1330
1321
1322
1323
1324
1326
1327
1328
1329
1331
1332
1333
1334
>>>>>>>>>>>> 24" RCP>>>>
>>
>>
>>
>>
>>
24" RCP
>>
24"RCP
13301328 13291331 1332
>>>>>>>>>>>>>>>>
7+09
.51
0+00
1+00
2+00
3+00
4+00
5+00
6+00 7+
00
1318
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
R
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
6.dw
g 10
/26/
2018
10:
39:4
7 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
6.1DRAIN TILE NO. 2 OUTLET PLAN AND PROFILE
6.1DRAIN TILE NO. 2 OUTLET PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
NWL: 1319.5
PLACE FILL OVER TOP OF PIPE, MIN. COVER 2.5'
RIP RAP BELOW TILEOUTLET 1.5' DEEP (8 TON)
CONNECT EXISTING 10" PE TILE TONEW 24" RCP W/CONC. COLLAR ANDMATCH FLOWLINES. REMOVEEXISTING TILE DOWNSTREAM.
EXISTING GROUND
REMOVE EXISTING TILE
CONNECT EXISTING 10" TILES TONEW 24" RCP W/CONC. COLLAR ANDMATCH FLOWLINES. REMOVEEXISTING TILES DOWNSTREAM.
EXISTING 10" PE TILE (DD. 54)EXISTING 10" CONC. TILE (DD. 54)
EXIST
ING 6"
PE TI
LE
CONNECT EXISTING 6" PE TILETO NEW 24" RCP
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
X
XX
XX
XX
REMOVE EXISTING 10" PE TILEAND EXISTING 10" CONC. TILE
EASEMENT BOUNDARY (TYP.)
ROLF AVE.
MINIMIZE DISTURBANCE THROUGH THIS AREA TO PROTECT EXISTING VEGETATION
RIP RAP BELOW TILEOUTLET 1.5' DEEP (8 TON)
EXISTING GRND ELEV. PROPOSED PIPE FLOWLINE ELEV.
NOTE:SEE CONSTRUCTION NOTES AND FIELD TILEREPAIR CONNECTION DETAIL SHEET NO. 6.0.
1300
1305
1310
1315
1320
1325
1330
1335
1340
1345
1300
1305
1310
1315
1320
1325
1330
1335
1340
1345
1318
.7
0+00
1319
.1
1319
.5
0+50
1319
.8
1320
.0
1+00
1320
.4
1320
.53
1320
.7
1+50
1320
.57
1321
.2
1320
.61
1321
.7
2+00
1320
.65
1322
.2
1320
.69
1322
.7
2+50
1320
.73
1322
.9
1320
.77
1323
.2
3+00
1320
.81
1323
.5
1320
.85
1323
.9
3+50
1320
.89
1324
.2
1320
.93
1324
.5
4+00
1320
.97
1324
.6
1321
.01
1324
.84+50
1321
.05
1325
.0
1325
.0
5+00
1324
.9
1324
.8
5+50 6+00 6+50 7+00 7+50
VPI:
1+34
.10
EL: 1
320.
50
VPI:
4+92
.74
EL: 1
321.
08
20'18" CMP@ 0.16%
340' - 12" HDPE @ 0.16%271' 12" HDPE@ 0.16%
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
EXISTING 10" CLAY TILE
STA: 3+25.00ELEV: 1323.50END FILL OVER 12" HDPE
>>
>>
>>
>>>>
>>>>>>>>
>>>>>>
>>>>>>>>>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>
>>
0+00
1+00 2+
00 3+00 4+
00
5+00
5+50>>>>>> 12" HDPE
>>>>>>>>>>>>>>>>>>>>>>
12" HDPE
1320
1325
1321 1322 1323
1324
1326
1327
1328
1329
13251324
1326
1327
1328
1329
1314 13151316 13171318 1319
13141315 13161317 13181319 1320 1321
R
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
6.dw
g 10
/26/
2018
10:
39:5
2 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
6.2DRAIN TILE NO. 3 OUTLET PLAN AND PROFILE
6.2DRAIN TILE NO. 3 OUTLET PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
CONNECT EXISTING 10" CLAY TILE TONEW 12" HDPE W/CONC. COLLARAND MATCH FLOWLINES. REMOVEEXISTING TILE DOWNSTREAM.
CONNECT EXISTING 10" CLAY TILE TONEW 12" HDPE W/CONC. COLLARAND MATCH FLOWLINES. REMOVEEXISTING TILE DOWNSTREAM.
NWL: 1319.5
PLACE FILL OVER TOP OF PIPE, MIN. COVER 2.0'
RIP RAP BELOW TILEOUTLET 1.5' DEEP (9 TON)
EXISTING GROUND
REMOVE EXISTING 10" TILE
RIP RAP BELOW TILEOUTLET 1.5' DEEP (9 TON)
EASEMENT BOUNDARY
REMOVE EXISTING CLAY TILE
EXISTING GRND ELEV. PROPOSED PIPE FLOWLINE ELEV.
NOTE:SEE CONSTRUCTION NOTES AND FIELD TILEREPAIR CONNECTION DETAIL SHEET NO. 6.0.
SEDIMENT BASIN (TYP.)
1290
1295
1300
1305
1310
1315
1320
1325
1330
1335
1290
1295
1300
1305
1310
1315
1320
1325
1330
1335
1313
.32
1313
.3
0+00
1319
.01
1319
.0
1314
.19
1316
.3
0+50
1312
.47
1312
.0
1312
.59
1312
.7
1+00
1311
.88
1314
.3
1311
.70
1315
.6
1+50
1319
.50
1315
.6
1315
.90
1315
.72+00
1315
.85
1315
.8
1315
.84
1315
.8
2+50
1316
.01
1316
.0
3+00 3+50 4+00
STA: 1+59.19ELEV: 1324.50TOP OF DIKE/BERM
STA: 1+59.19ELEV: 1319.50TOP OF SHEET PILE WEIR
ELEV: 1311.70STILLING BASIN
STA: 1+22.54ELEV: 1312.70
STA: 0+50.09FL ELEV: 1312.355'x5' TWIN RCBC
STA: 0+36.27ELEV: 1319.53
CL 390TH ST.
TEMPORARY BERM FOR SHEET PILEINSTALLATION, REMOVE UPON
COMPLETION OF PILING
GROUTED RIP RAP, PLACE RIPRAP TO 1.5' DEPTH
NWL: 1319.5
CLAY CORE TRENCH (SEE SHT NO. 4.1,TYPICAL X-SECTION OF EMBANKMENT)
EXISTING GROUND
10'
10'
RIP RAP
XX
XX
XX
XX
XX
XX
XX
X>>
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
XX
XX
XX
XX
X
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>
>>
>>
>>
>>>>
>>
>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
0+00
1+00
2+00
2+78
.08
>>>>
>>>>
6" H
DPE
>>>>
>>>>
6" H
DPE
>>
>>
>>>>
WATER CONTROL STRUCTURE
STOP LOG STORAGE
CMP SLOTTED INTAKE RISER
18" CMP
18" CMP
18"
CMP
1320
1316
1316
1316
1316
1317
1317
1318
1319
1321
1315
1316
1317
1316
1317
1318
1320
1320
1320
1320 13
241324
1324 13
20
1324
1320
1320
1319 13
16
1316
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
7.dw
g 10
/26/
2018
10:
40:0
2 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
7.0STILLING BASIN PLAN AND PROFILE
7.0STILLING BASIN PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
390T
H ST
.
EXISTING 5'x5' TWIN RCBC
NOTE:RIP RAP 4' UPSTREAM OF THE SHEET PILE WEIR SHALLBE GROUTED WITH A SMOOTH TROWEL FINISH.
TOE DRAIN
TOE DRAIN
.
REMOVE EXISTING FENCE THROUGHOUTLET CHANNEL
(INCIDENTAL TO EXCAVATION)
EXISTING GRND ELEV. PROPOSED ELEV.
R
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X XX
X
XX
XX
XX
XX
XX
XX
XX
XX
XX
PLACE 1.5' DEPTH OF RIP RAP (475 TON)W/640 SY OF ENGINEERING FABRIC
(INCIDENTAL)
BOTTOM OF SHEET PILEELEV: 1303.50
GROUTEDRIP RAP
PERMANENT EASEMENT
1294
1296
1298
1300
1302
1304
1306
1308
1310
1312
1314
1316
1318
1320
1322
1324
1326
1328
1330
1332
1294
1296
1298
1300
1302
1304
1306
1308
1310
1312
1314
1316
1318
1320
1322
1324
1326
1328
1330
1332
1324
.50
1315
.8
4+40
1324
.50
1315
.7
4+50
1324
.50
1315
.64+60
1324
.50
1315
.5
4+70
1324
.33
1315
.5
4+80
1320
.99
1315
.5
4+90
1319
.50
1315
.6
5+00
1319
.50
1315
.6
5+10
1319
.50
1315
.8
5+20
1320
.67
1316
.0
5+30
1324
.01
1316
.3
5+40
1324
.50
1316
.6
5+50
1324
.50
1317
.1
5+60
1324
.50
1317
.5
5+70
1324
.50
1317
.9
5+80
FINISH TOP OF SHEET PILE WEIRCL STA: 5+10.48ELEV: 1319.50
STA: 4+64.48ELEV: 1324.50
STA: 4+79.48ELEV: 1324.50
STA: 5+41.48ELEV: 1324.50
STA: 5+56.48ELEV: 1324.50
STA: 4+94.48ELEV: 1319.50
STA: 5+26.48ELEV: 1319.50
STA: 4+64.48ELEV: 1310.00 STA: 4+94.48
ELEV: 1310.00
STA: 4+94.48ELEV: 1303.50
STA: 5+26.48ELEV: 1303.50
STA: 5+26.48ELEV: 1310.00
STA: 5+56.48ELEV: 1310.00
STA: 5+10.48ELEV: 1311.70STILLING BASIN
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C07
.1.d
wg
10/2
6/20
18 1
0:40
:11
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
7.1SHEET PILE SECTION AND DETAILS
7.1SHEET PILE SECTION AND DETAILSFEETSCALE
0 10 20HORZ.
FEETSCALE
0 2 4VERT.
TOP OF DIKE/BERMELEV: 1324.5
EXISTING GROUND
BTM OF CORE TRENCH
0.2'
CLE
AR
UPSTREAM RIP RAP ELEV: 1319.3,SUBGRADE ELEV: 1317.8
DOWNSTREAM RIP RAP ELEV: 1311.7,SUBGRADE ELEV: 1310.2
NOTES:THE SHEET PILE SECTIONS SHOWN ARE FOR AN ASSUMEDWIDTH OF 24", IF THE SUPPLIED MATERIAL IS A DIFFERENTWIDTH, THEN THE APPROPRIATE ADJUSTMENTS WILL NEED TOBE MADE IN THE QUANTITIES FOR THE VARIOUS LENGTHS.
NOTES:
1. ALL BOLTS WILL BE 1" DIA. WITH 2 WASHERS. BOLT SHALL BE EXTENDED A MINIMUM OF 38" BEYONDTHE NUT.
2. ALL HOLES SHALL BE DRILLED 116" DIA. LARGER THE THE BOLT.
3. IT IS RECOMMENDED THAT THE WALER SHALL BE PLACED ON THE DOWNSTREAM SIDE OF THE WEIR.
4. ANY HOLES LEFT IN SHEET PILE (LIFTING HOOKS ETC.) SHALL BE CLOSED OFF TO NOT ALLOW WATERTO FLOW THROUGH SHEET PILE.
5. AFTER SHEETING AND WALER INSTALLATION ALL SHEETING IS TO BE CUT TO CONFORM WITH 3:1SLOPE.
6. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDING WITH THE LATESTSPECIFICATION OF AISC. FABRICATOR SHALL SUBMIT SHOP DRAWINGS. FABRICATE AFTERENGINEERS REVIEW.
7. DEFLECTIONS SHALL BE MADE IN FABRICATED PIECES AND STILL CONFORM TO THE DIMENSIONSGIVEN.
8. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE ALLOWABLE CONSTRUCTION LIVE LOADS.
9. PROVIDE ALL NECESSARY TEMPORARY BRACING, SHORING, GUYING OR OTHER MEANS TO AVOIDEXCESSIVE STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION.
10. IF CONTRACTOR WISHES TO WELD WALER TO SHEET PILE INSTEAD OF BOLTING, CONTRACTOR MUSTPROVIDE ENGINEER THE DESIGN AND SPECIFICATIONS THEY INTEND TO FOLLOW.
DESIGN SHEET PILING AREA IS 1307 SF - AFTERTRIMMING
SHEET PILING REQUIREMENTS
MINIMUM SECTION MODULUS OF 6.04 CUBICINCHES PER FOOT OF WALL.MINIMUM GRADE OF STEEL IS 25 KSI.MINIMUM MOMENT OF INERTIA OF 16.76 INCHES ^ 4 PER FOOT OF WALL.ALL SHEETING SHALL MEET ASTM A-328, A-572GR50.
RECOMMENDED STEEL CHOICES:
SKYLINE STEEL SKS 11 OR EQUIVALENTSHORELINE STEEL SZ-10 OR EQUIVALENTCONTECH SZ-10 OR EQUIVALENTLB FOSTER PZC 13 OR EQUIVALENTGERDAU AMERISTEEL (CHAPPARRAL) PZC 13 OREQUIVALENT
OTHER SHEETING MAYBE ALLOWED WITH PRIORAPPROVAL OF ENGINEER.
BOLT DETAILNOT TO SCALE
GROUTED RIPRAPMETAL SHEET PILING
GEOTEXTILE FABRIC
18"
GROUTED RIPRAP DETAILNOT TO SCALE
FLOWDIRECTION
NOTE: 1 BOLT TO BE PLACED ON EACH SIDE OF SPLICE
0.2'
CLE
AR
WALER BOLT PLACEMENTNOT TO SCALE
C10X15.3 WALERCONTINUOUS
1" BOLT W/ (2) WASHERS
SHEET PILESPLICE
SHEET PILE
SHEET PILESPLICEC10X15.3
WALER CONT.
SHEET PILE
C10X15.3 WALER CONT.
1" BOLT W/ (2) WASHERS
EXISTING GROUND TOP OF WEIR & DIKE/BERM ELEV.
3:13:1
3:13:1
NOTE:AN AREA 4' WIDE ADJACENT TO THE SHEET PILE,EXTENDING THE LENGTH OF THE WEIR SHALL BECONSTRUCTED FROM EXCESS GROUT TO HAVE AFLAT, LEVEL SURFACE WITH FLOAT FINISH. NOPORTION OF THIS AREA OR THE RIP RAP UPSTREAMSHALL EXCEED ELEVATION 1319.3'.
PP
XXXXXXXXXXXXXXXXXX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
X X X X X X X X X X X X X X X X X X
XOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
X X
>> >> >> >> >>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>
>>
>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
8.dw
g 10
/26/
2018
10:
40:2
2 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
8.0SEEDING AREAS
8.0SEEDING AREASFEETSCALE
0 100 200HORZ.
390TH ST.
ROLF
AVE
.EASEMENT BOUNDARY (TYP.)
NORMAL POOL (NO SEEDING)ELEV: 1319.5AREA: 5.16 ACRES
STRUCTURE SEEDING
STRUCTURE SEEDING
SITE ACCESS POINT
DRAINAGE DISTRICT NO. 54 EXISTING TILE
R
SEEDING NOTES:
1. ALL SEED BEDS SHALL BE PREPARED AS SPECIFIED IN SECTION IA-6.
2. ALL ROCKS 3" OR LARGER IN DIAMETER SHALL BE REMOVED FROM THE SEEDBED.
3. CONTRACTOR SHALL SUBMIT A SEEDING PLAN ON FORM IA-CPA-4 FOR EACH TYPE OFSEED TO BE PROVIDED AT LEAST 3 WEEKS PRIOR TO BEGINNING SEEDINGOPERATIONS.
4. NO SEED TO BE PLACED BELOW THE NORMAL WATER ELEVATION.
5. THE 10' ACCESS BENCH ALONG THE PERIMETER OF THE POOL AREA SHALL BE GRADEDTO A UNIFORM SURFACE.
6. MULCH SHALL BE APPLIED TO ALL STRUCTURE SEEDING AND CHANNEL SEEDINGAREAS; NO MULCH TO BE APPLIED TO THE BUFFER SEEDING.
7. SEEDED AREAS WHERE MULCH IS REQUIRED SHALL BE MULCHED WITHIN 24 HOURS.
8. ALL MULCH SHALL BE ANCHORED.
9. SEED TYPES SHALL AS SPECIFIED IN SECTION IA-6 OF THE PROJECT MANUAL.
10. EXISTING VEGETATION SHALL BE REMOVED OR KILLED BY APPLICATION OF HERBICIDEPRIOR TO PREPARATION FOR SEEDING. THIS AREA WILL BE DETERMINED BY THEENGINEER.
11. ANY EXISTING VEGETATION AREAS (BUFFER) THAT ARE TO REMAIN UNDISTURBEDWILL BE DETERMINED IN THE FIELD BY THE ENGINEER AND WILL BE FIELD MEASUREDTO DETERMINE FINAL QUANTITY OF BUFFER SEEDING, NO CHANGE IN CONTRACTPRICE WILL BE ALLOWED DUE TO CHANGE IN SEEDING AREAS.
SEEDING QUANTITIES:
20.4 ACRES - TOTAL EASEMENT AREA
5.2 ACRES - NORMAL WATER LEVEL POOL AREA (NO SEEDING)
0.2 ACRES - RIP RAP OUTLET CHANNEL
0.7 ACRES - STRUCTURE AND CHANNEL
14.3 ACRES - BUFFER (SEE SEEDING NOTES NO. 10 & 11)
0.4 ACRES - BUFFER OUTSIDE OF EASEMENT AREA
OWNER:PARTRIDGE, D.G. & ROSEMARY N.
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1313
.3
0+00
1319
.0
1316
.3
0+50
1312
.47
1312
.0
1312
.59
1312
.7
1+00
1311
.88
1314
.3
1311
.70
1315
.6
1+50
1319
.50
1315
.6
1315
.7
2+00
1315
.8
1315
.8
2+50
1316
.0
1316
.2
3+00
1316
.3
1316
.2
3+50
1316
.2
1316
.3
4+00
1316
.4
1316
.44+50
1316
.5
1316
.6
5+00
1316
.7
1316
.9
5+50
1317
.1
1317
.4
6+00
1317
.5
1317
.6
6+50
1317
.7
1317
.9
7+00
1318
.1
1318
.3
7+50
CL 3
90TH
ST. STA: 1+59.19
ELEV: 1324.50CL DIKE/BERM
STA: 1+59.19ELEV: 1319.50TOP OF SHEET PILE
STA: 1+59.09ELEV: 1311.70STILLING BASIN
STA: 1+25.54ELEV: 1311.70STILLING BASIN
STA: 0+50.09ELEV: 1312.35EXISTING 5'x5' RCBC
0+00
1+00
2+00
3+00
4+00
5+00
6+00
7+00
1316
1317
13181319
1320
1321
1322
1323
1315
1316
1317
1318
1319
13171318
131613
1613
17
1318
1317
1318
1319
1316
1316
1319
1316
1317
1318
1319
1320
1321
1322
1323
1324
1324
1323
1322
1321
1320
1319
1318
1316
1317
1317
1319
1320
1321
1322
1323
1324 13
2413
2313
2213
2113
2013
1913
1813
17
XX
XX
XX
XX
XX
XX
XX
XX
>>
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
XX
XX
XX
X
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>
>>>>>>>>>>>>>>
>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>>>>>>>>>>>>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
01
2
3
45
0
1
2
3
4
5
0
1
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XX
XX
XX
XX
X
X
X
X
XX
XX
XX
XX
XX
XX
XX
XX
X
XX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
0
1
1
>>
>>
>>>>
>>>>
>>
>>>>
>>>>
>>>>0
1
2
3
4
5
X
X
XX
X
XX
XX
XX
XX
XX
XX
XXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
13191318
R
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
9.dw
g 10
/26/
2018
10:
40:3
3 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
9.0WETLAND CENTERLINE PLAN AND PROFILE
9.0WETLAND CENTERLINE PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
390T
H ST
.
NWL ELEV: 1319.5
EXISTING TWIN 5'x5' RCBC
EXISTING TWIN 5'x5' RCBC
EASEMENTBOUNDARY
EXISTING GRND ELEV. PROPOSED CL WETLAND ELEV.
WATER CONTROLSTRUCTURE
SLOTTED INTAKE RISER
WETLAND CENTERLINE
SUBMERGED BERM'S, TOP ELEV: 1319.0',TOP = 5' WIDTH W/3:1 SLOPES
SUBMERGED BERM
GROUTEDRIP RAP
TOE DRAIN
TOE DRAIN
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1295
1300
1305
1310
1315
1320
1325
1330
1335
1340
1318
.3
7+50
1318
.6
1318
.8
8+00
1318
.7
1315
.48
1319
.0
8+50
1317
.64
1319
.3
1319
.4
9+00
1319
.30
1319
.5
1319
.17
1319
.6
9+50
1319
.7
1320
.1
10+00
1320
.8
1321
.4
10+50
1321
.6
1321
.7
11+00
1321
.9
1322
.2
11+50
1322
.6
1322
.912+00
1323
.2
1323
.4
12+50
1323
.7
1323
.9
13+00 13+50 14+00 14+50 15+00
EASE
MEN
T BO
UN
DARY
6+00
7+00
8+00
9+00
10+0
0
11+0
0 12+0
0 13+0
0
13+1
4.44
1319
>>>>>>>>>>>>>>>>>>>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>
>>>>>>>>>>>>
>>>>
>>
>>
>>
>>
>>
>>>>
>>>>
4
5
6
7
8
9
10 11
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
2
>>>>>>12" HDPE
>>>>
>>>>
>>>>
>>>>
>>>>
>>
12" HDPE
1320
1321 1322
1323
1324
1325
13261327
13281329
1326
1324
1325
1323
1322
1321
1320
1319
1319
1318
1314131513161317
1318
1314 13151316 13171318 1319
13191320 1321
R
SHEET
Bol
ton
& M
enk,
Inc.
201
8, A
ll Ri
ghts
Res
erve
dc H:
\IDA
LS\A
1411
5046
\CAD
\C3D
\She
et D
wgs
201
8\11
5046
_C00
9.dw
g 10
/26/
2018
10:
40:3
6 AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
REVISION DATENO.
R
300 WEST MCKINLEY ST, P.O. BOX 68JEFFERSON, IOWA 50129
Phone: (515) 386-4101Email: [email protected]
www.bolton-menk.com
IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIPSAC COUNTY CREP PROJECT NO. SAC863635C
RMC
RMC
JDL
A14.115046
1 IDALS 10/18/18
9.1WETLAND CENTERLINE PLAN AND PROFILE
9.1WETLAND CENTERLINE PLAN AND PROFILEFEETSCALE
0 25 50HORZ.
FEETSCALE
0 5 10VERT.
NWL ELEV: 1319.5
SILT SEDIMENT BASIN
EXISTING GROUND
SILT SEDIMENT BASIN
NORMAL POOL ELEV: 1319.5
EASEMENTBOUNDARY
EXISTING GRND ELEV. PROPOSED CL SILT BASIN ELEV.
WETLAND CENTERLINE