connect with cpc! cpc... · 2016. 9. 6. · connect with cpc! “the leader in single-use...
TRANSCRIPT
Connect with CPC! “The Leader in Single-Use Connection Technology”
COMPANY OVERVIEW
• CPC is a leader in the design and manufacture of single-
use connection technologies for biopharmaceutical drug
development and production
• Founded in St. Paul, Minnesota in 1978
• Selling into the bioprocessing market for over 20 years
• Global distribution with sales offices in USA, Europe,
Hong Kong, China, and Japan
2
SINGLE-USE CONNECTORS FOR BIOPROCESSING
3
Quick Connects – MPC/MPX
SaniQuik
Back to Back Adapters
SINGLE-USE CONNECTORS FOR BIOPROCESSING
4
SIP Connectors Sterile Connectors
Sterile Connect /Sterile Disconnect Sterile Disconnect
SIP Connector/Sterile Connect
Videos available at colder.com/bio
MATERIALS OF CONSTRUCTION
• Materials (depending on connector):
- Polysulfone USP Class VI
- Polycarbonate USP Class VI
- Seals:
- Silicon USP Class VI
- Membranes: Polyethylene & PES (HT)
- Flow path components are animal free
• Sterilization:
- Gamma up to 50kGy
- Autoclave up to 130◦ C
5
STEAM-THRU ® CONNECTIONS
• Designed to create a sterile connection between
stainless steel bioprocess equipment and single-use
systems
• 3-port design for a true steam-through SIP process
• No Dead legs
• Reduces cleaning and sterilization validation
• STC I – Steam On
• STC II – Steam On & Steam Off
6
ASEPTIQUIK® STERILE CONNECTORS
• AseptiQuik S – Genderless
• ⅛” to ⅜” HB
• ¾” Sanitary
• MPC Insert
7
ASEPTIQUIK® STERILE CONNECTORS
• AseptiQuik G – Genderless NEW! • ¼” to ¾” HB
• ¾” Sanitary
8
GENDERLESS – ADVANTAGES
• No Extra Equipment required to Connect
• Simplifies SOP’s
• Simplifies Ordering Process
• Hit volume breaks quicker
9
ASEPTIQUIK® STERILE CONNECTORS
• AseptiQuik C– Male/Female
• ⅜ & ½” HB
• ¾” Sanitary
10
ASEPTIQUIK® STERILE CONNECTORS
• AseptiQuik X – Male/Female
• ¾” & 1” HB
• 1 ½” Sanitary
• A true 1” Flow path!
11
ASEPTIQUIK® STERILE CONNECTORS
• Easy to Use – reduces risk of operator error
• Robust Construction – Reliable performance without the
need for need for additional fixtures, clamps or tube welders
• Colder Click – Audible confirmation of completed assembly
steps
• Membrane Pull Tabs – Ensure simultaneous & secure
removal of both membranes
• Secondary Equipment – Doesn’t need other items to secure
the connection
12
ASEPTIQUIK® TESTING
• Ingress Testing
• Bacterial Challenge
• Helium Leak Rate Flow Test
• Burst Test
• Tensile Test
• Creep Rupture Test
• Biocompatibility (Class VI)
• Extractables
• Validation Guides - download from colder.com/bio
13
CONTACT DETAILS
MICRO INDUSTRIES IRELAND
Dave O’Donovan
087-2347168
For additional information visit:
www.colder.com/bio
14
THANK YOU
15