Transformers & ConnectorsFor Aeronautical Ground Lighting Circuits

Page 2: CONECTORI TRAFO SEPARATIE

Efla �

Company information

Efla Oy

Efla Oy is a leading manufacturer of high-quality AGL transformers, connector kits and prefabricated cable assemblies for aeronautical ground lighting. Our experience stretches back almost 30 years. Efla’s first products were developed under the name Ensto. Due to the growth of the AGL business, a new company was established in September 2003 to concentrate on supplying products for AGL. Efla Oy is part of the EM Group Oy (see page 14 for more details).

For twenty years time our products have been serving various airfields worldwide, including almost every country in Europe, at locations such as Ghangi in Singapore, Schiphol in Amsterdam, Frankfurt, Madrid, Charles de Gaulle, Sydney and Dubai International Airport.

Efla Oy offers has a broad range of standard products and customized solutions. We focus on creating high-tech engin-eering designs with a variety of performance features in order to provide the optimum solution. Customer needs form the basis of Efla Oy’s mission to meet these requirements. The products’ technical quality, design, materials, customized solutions, and electrical and dimensional specifications are based on our long experience. Continuous improvement forms part of our processes which increases overall quality. Efla Oy has been granted the Quality Management System ISO9001:2000 and Environmental Management 14000:1996 certificates.

Contents

Page

Company information 2

Primary Connector Kits 3-5

Secondary Connector Kits 6-7

AGL Series Transformers 8-9

Prefabricated Secondary Leads 10-11

Accessories 12

Voltage Transformers for Parallel Circuits 13

Materials 14

Certificates 15

Page 3: CONECTORI TRAFO SEPARATIE

Efla �

Primary Connector Kits

KD500 series Quick installation with conductive parts, screen continuity and insulation parts filled with silicon grease.

KDR600 seriesA resin-type primary connector kit for the achievement of an indissoluble plug and receptacle connection. Efla’s resin-type connector is supplied with a high performance PU resin to be poured inside the insulation body around the connective parts and screen continuity.

KD510 series Quick installation with conductive parts, and insulation parts filled with silicon grease.

KDR610 seriesA resin-type primary connector kit for the achievement of an indissoluble plug and receptacle connection.

Efla’s resin type connector is supplied with a high performance PU resin to be poured inside the insulation body around the connective parts.

Efla’s primary connector kit is a package of parts for assembly into a primary cable. Each package contains parts for a pair (a plug and a receptacle), resulting in a post-assembly watertight connection of �5A and 5000V. Efla’s connector kits are for screened (shielded) cable and unscreened (unshielded) cable. All of our primary connector kits comply with the appropriate FAA 5�45-�6 requirements for plugs and receptacles (cable connectors).

For screened (shielded) cable:

For Unscreened (unshielded) cable:

Page 4: CONECTORI TRAFO SEPARATIE

Efla 4

Primary Connector Kits

Efla Type for Efla Type forscreened cable unscreened cable FAA L-8�� Conductor size Cable diameter sqmm AWGKDR600 KDR610 Style 3, Style 10 6 mm2 9-19 mm (AWG 8 up to 19 strands)KDR600.2 KDR610.2 Style 3, Style 10 10 mm2 9-19 mm (16 sqmm stranded) AWG 6

KDR610 series

Current rating: 25 AVoltage rating: 5.000 VNominal cross-section: 6 mm2/10 mm2

Cable diameter ranges from 10 mm to 22 mm

Current rating: 25 AVoltage rating: 5.000 VNominal cross-section: 6 mm2/10 mm2

Cable diameter ranges from 9 mm to 19 mm

Efla Type Efla Type FAA L-823 Conductor size Cable diameter Diameter of for screened for unscreened cable insulationcable cable sqmm AWG KD500 KD510 Style 3, Style 10 6 mm2 AWG 8 (up to 19 strands) 10.0 - 14.5 mm 7.0 - 10.5 mm KD500.1 KD510.1 Style 3, Style 10 6 mm2 AWG 8 (up to 19 strands) 14.0 - 18.5 mm 10.0 - 13.5 mm KD500.2 KD510.2 Style 3, Style 10 10 mm2 (16 mm2 stranded) AWG 6 14.0 - 18.5 mm 10.0 - 13.5 mm KD500.3 KD510.3 Style 3, Style 10 6 mm2 AWG 8 (up to 19 strands) 18.0 - 22.0 mm 12.5 - 16.0 mm KD500.4 KD510.4 Style 3, Style 10 10 mm2 (16 mm2 stranded) AWG 6 18.0 - 22.0 mm 12.5 - 16.0 mm KD500.5 KD510.5 Style 3, Style 10 10 mm2 (16 mm2 stranded) AWG 6 10.0 - 14.5 mm 7.0 - 10.5 mm KD500.6 KD510.6 Style 3, Style 10 6 mm AWG 8 (up to 19 strands) 8.5 - 11.5 mm 5.0 - 7.5 mm

KD510 can also be used for cables with a diameter of 7 - 10 mm, if sealed in the inner sealing surface. Please contact the factory for further information.

KD500 series

Screen continuity

The standard version of screen continuity is 2.5 mm2 tinned copper wire, 300 mm long.

Upon request, KD500 can be supplied with insula-ted screen continuity in yellow-green (KD500/YG) or black (KD500/B).

KD510 series

KDR600 series

Crimping Tools for standard version, some suitable types

Conductor size 4 - 6 mm2

• Elpress EWB 4099C or Klauke K24

KD500 KD500/YG KD500/B

Page 5: CONECTORI TRAFO SEPARATIE

Efla 5

Primary Connector Kits

Each kit contains:

• 1 pair of crimp type connecting parts (pin and socket)• 1 pair of plug and receptacle housings• 1 locking device (polypropylene)• Silicone grease (inside the housing)• Guiding pin for receptacle (PA or PP)• Cleaning cloth• Installation instructions

KD500 -series, for screened (shielded) cable

KD510 -series, for unscreened (unshielded) cable

Efla Type Weight/�pc Standard packing Weight/50pcs CbmKD500 -series 130g 50pcs 6.5kg 0.02 cbmKD510 -series 110g 50pcs 5.5kg 0.02 cbm

Weight and packing

EFLA type D L K KD500 KD510 23.5 mm 95 mm 127 mm KD500.1 KD510.1 23.5 mm 95,5 mm 127 mm KD500.2 KD510.2 23.5 mm 95,5 mm 127 mm KD500.3 KD510.3 23.5 mm 92 mm 123 mm KD500.4 KD510.4 23.5 mm 92 mm 123 mm KD500.5 KD510.5 23.5 mm 95,5 mm 127 mm KD500.6 KD510.6 23.5 mm 95,5 mm 127 mm

Efla Type Weight/�pc Standard packing Weight/�64 pcs Cbm KDR600-610 series 320 g 364 pcs 147 kg 0.72 cbm

Weight and packing

In addition, in the

KD500 series:

• 2 screen continuity connectors (tin-plated brass) with 350 mm long 2.5 mm2 copperwires• 1 terminal block with 2 screws (nickel-plated brass); connector housing made of polyamide 6.6

KD500 and KD5�0 series

KDR600 and KDR6�0 series

KDR600 -series, for screened (shielded) cable

KDR610 -series, for unscreened (unshielded) cable

Each KDR610 series

package contains

* Plug and receptacle housing* Metal parts, pin and socket * Resin bag (resin+hardener) * Guiding pin for receptacle, * Locking device, * Gloves, sandpaper, installation instructions.

In addition, in the

KDR600 series:

* 2 screen continuity connectors (tin-plated brass) with 350 mm long 2.5 mm2 copper wires* 1 terminal block (6 mm2) with 2 screws (nickel-plated brass); connector housing made of polyamide 6.6

Page 6: CONECTORI TRAFO SEPARATIE

Efla 6

Secondary Connector Kits

Efla’s secondary connector kit is a package of parts to be assembled into a secondary cable or wire. Each package contains parts for a plug or receptacle. The result after assembly is a watertight connection of �0 A and 600 V. Efla’s secondary connector kits comprise two core cable or two single core wires. All secondary connector kits comply with latest FAA 5�45-�6 requirements for plugs and receptacles (cable connectors).

For two core cable:

Technical specification

Current rating: 20 AVoltage rating: 600 VNominal cross-section:1.5-2.5 mm2/4 -6 mm2

Efla Type Type FAA L-8�� Conductor size Cable diameterKD501 Plug Style 5 1.5 - 2.5 mm2 8.5 - 13.5 mmKD501.1 Plug Style 5 4.0 - 6.0 mm2 11.5 - 18.0 mmKD501.2 Plug Style 5 4.0 - 6.0 mm2 8.5 - 13.5 mmKD502 Receptacle Style 12 1.5 - 2.5 mm2 8.5 - 13.5 mmKD502.1 Receptacle Style 12 4.0 - 6.0 mm2 11.5 - 18.0 mmKD502.2 Receptacle Style 12 4.0 - 6.0 mm2 8.5 - 13.5 mm

KD501 and KD502 series for two-core cables:

KD501 series (Plug)

KD502 series (Receptacle)

Efla offers two secondary connector-type options that consist of a body with connective parts and insulation.

Page 7: CONECTORI TRAFO SEPARATIE

Efla �

Secondary Connector Kits

KD503 and KD503R -series for two single wires:

Efla Type Type FAA L-8�� Conductor size Wire diameterKD503 Plug Style 4 1.5 - 2.5 mm2 2.8 - 4.0 mm (x 2)KD503.1 Plug Style 4 4.0 - 6.0 mm2 3.8 - 5.5 mm (x 2)KD503.2 Plug Style 4 4.0 - 6.0 mm2 2.8 - 4.0 mm (x 2)KD503.3 Plug Style 4 4.0 - 6.0 mm2 5.0 - 8.0 mm (x 2)KD503R Receptacle Style 11 1.5 - 2.5 mm2 2.8 - 4.0 mm (x 2)KD503R.1 Receptacle Style 11 4.0 - 6.0 mm2 3.8 - 5.5 mm (x 2)KD503R.2 Receptacle Style 11 4.0 - 6.0 mm2 2.8 - 4.0 mm (x 2)KD503R.3 Receptacle Style 11 4.0 - 6.0 mm2 5.0 - 8.0 mm (x 2)

Versions contains:

• 1 body with connecting parts• 1 plug or receptacle housings• Silicone grease tube• Cleaning cloth• Installation instructions

KD502 -series KD503R -series

KD501 -series KD503 -series

Crimping Tools for Secondary connectors

Efla Type Weight/�pc Standard packing Weight/�00pcs CbmKD501-503 series 40 g 100 pcs 5 kg 0.02 cbm

KD503 -series

For two single wires:

KD503R -series

63 mm

ø25 mm

ø25 mm

63 mm

Weight and packing

Secondary connectors Crimping Tool:For conductors 1.5 - 2.5 mm2 ELPRESS DKB 0760Conductor size: 4 - 6 mm2 ELPRESS EWB 4099C

Page 8: CONECTORI TRAFO SEPARATIE

Efla 8

AGL Series transformers

Efla’s AGL series transformers are high quality products designed and manufactured to comply with the majority of international standards and requirements. The toroidal shape of the transformers is optimum for the sizes regularly used in supplying lights in airfields. Transformers are approved by the IEC and/or FAA and also comply with ICAO annex �4 and several national standards.

The range of Efla’s AGL series transformers covers all types and powers normally used in AGL circuits, in-cluding the new LED types. Beyond this, Efla can customize the transformation ratio, lead length and many other features.

Efla uses modern high performance materials and the latest machinery to achieve encapsulation fulfilling the most demanding requirements. Water tightness is achieved using several water barriers resistant to the latest chemicals used in airfields, while the encapsulation material has excellent electrical characteris-tics and good resistance to weathering.

Primary leads

• The transformers have two primary leads, standard length 0.6 m, cross section min. 6 mm2

• One lead with FAA L-823, Style 2 plug• One lead with FAA L-823, Style 9 receptacleSecondary leads

• The transformers have one secondary lead of 1.2 m in length with cross-section min. 2.5 mm2, min. 0.6 kV.• Secondary lead fitted with a style 8 connector• Upon request, the transformers can be equipped with other cable sizes and lengths or with a style 7 connector

With earthing (grounding) or without earthing

Efla can supply transformers with or without earthing. If earthing is requested it is connected to the end of the secondary winding in the side of the larger socket.

Small

Large

Primary Secondary

Transformers can be installed using several met-hods and Efla also provides a transformer caddy in which Efla transformers of all sizes can be hung. Transformers are also suitable for direct burial in soil.

Efla’s AGL series transformers are available with and without earthing (grounding). Transfor-mers without earthing must be ordered using the appropriate suffix, for example KR54�.�. An earthing stud is connected to thesecondary winding, to which the larger secondary socket is connected.

Each year, Efla tests each and every transformer in several phases, recording the test results. Test results can be supplied alongside the trans-formers, if requested in advance.

Style 8 Style 7

Page 9: CONECTORI TRAFO SEPARATIE

Efla �

AGL Series transformers

Efla Type D L H (height) Weight Standard gross mm mm mm kg packing* pcs weight cbmKR531, KR531.1 100 125 55 1.7 240 430 kg 0.55 cbm KR536, KR536.1 126 168 56 2.3 144 454 kg 0.55 cbmKR541, KR541.1 147 193 54 3.0 144 454 kg 0.55 cbmKR546, KR546.1 147 193 60 3.3 135 470 kg 0.55 cbmKR551, KR551.1 147 193 64 3.8 126 500 kg 0.55 cbmKR561, KR561.1 147 193 73 4.8 108 540 kg 0.55 cbm

* The standard packing is recyclable cardboard, size 1180 x 780 x 500 mm, on a wooden pallet. On request, the transformers can be packed in seaworthy wooden crates.

Dimensions and packing

Efla Type Short OpenRated Rated Efla Type without Power Load Efficiency Power circuit circuitpower Current with earthing FAA Type range IEC IEC Factor current voltage[W] [A] earthing ETL Certified [W] Ohm % % [A] V (rms)30/45 6.6/6.6 KR531 KR531.1 L-830-1 L-831-1 25-60 0.57-1.38 > 85 > 0.97 < 6.7 < 1365 6.6/6.6 KR536 KR536.1 L-830-3 L-831-3 50-85 1.15-1.49 > 90 > 0.97 < 6.7 < 16100 6.6/6.6 KR541 KR541.1 L-830-4 L-831-4 80-125 1.84-2.87 > 90 > 0.97 < 6.7 < 23150 6.6/6.6 KR546 KR546.1 L-830-19 L-831-19 120-178 2.75-4.13 > 90 > 0.97 < 6.7 < 25200 6.6/6.6 KR551 KR551.1 L-830-6 L-831-6 160-230 3.67-5.28 > 90 > 0.97 < 6.7 < 41300 6.6/6.6 KR561 KR561.1 L-830-10 L-831-10 220-338 5.05-8.25 > 90 > 0.97 < 6.7 < 70LED-Transformers�0/�5 6.6/6.6 KR5�� KR5��.� L-8�0-��/ L-8��-�� �0-�5 0.�4 (FAA) - > 0.�5 (FAA) < 6.� < 8�0/�5 6.6/6,6 KR5�5 KR5�5.� L-8�0-�8/ L-8��-�8 �0-�5 0.5� (FAA) - > 0.�5 (FAA) < 6.� < 8

AGL series transformers with the ratios 20 A/6.6 A and 8.3 A/6.6 A are also available.

When ordering, use the .83 suffix after the transformer type. For example, KR541.83.1.

Page 10: CONECTORI TRAFO SEPARATIE

Efla �0

Prefabricated Secondary Leads

Efla manufactures a wide range of secondary leads for installation according to customer requirements, from half a meter to several hundred meters in length. The result is a high performance secondary circuit and very rapid installation. The majority of this group comes with two core cables and only a small num-ber with two single core wires.

The other group comprises light fixture (and other equipment) supply leads with different kinds of cable and wires. Depending on the OEM solution, two core cables are widely used, as are two single core wires with a different temperature resistance.

Cross-section options are �.5 mm�, �.5 mm� and 4 mm� in two core cables. Cross-section options are �.5 mm� and 4 mm� in wires.

The connector body’s material is modern synthetic elastomere with high electrical and weathering resis-tance:

Extension cords:

The above types are possible with a specific length, with a plug on one end and a receptacle on the other. For example, the type is KDCE501.4.30000 (4 sqmm and 30 m).

Cable information:

Secondary two core cables are EPR–insulated and TPE–sheathed with stranded bare copper conductor. Cables are in accordance with the specifications FAA L-824 (MIL-C-3432 or ICEA S- 66-524) or MIL-C-4921 in general. Possible cross-sections are 1.5 mm2 (OD 8,5mm), 2.5 mm2 (OD 10,0 mm) and 4 mm2 (OD 12 mm). Nominal voltage is 600V. Bending radius is 5D fixed, 10D flexible.

KDC 501-series, Style 1 KDC 502-series, Style 7 KDC 508-series, Style 8

Secondary connectors with two core cables:

Page 11: CONECTORI TRAFO SEPARATIE

Efla ��

Prefabricated Secondary Leads

Also available with teflon wires. Temperature resis-tance, 200°C.

Secondary connectors with two single core wires:

KDCO1 2 pcs 6.3 flat connectors, uninsu-lated

KDCO2 2 pcs 6.3 flat connectors with double insulator (210°C)

KDCO3 2 pcs 6.3 flat connectors with 2 single insulator

KDCO4 2 pcs diam 4 uninsulated circular connectors

Assembly is included in the code (and price). Please order separately.

Free end of the leads:

The standard free end is sheath stripping of 3 cm. The following possibilities are available to order from Efla with the lead.

Cable information

The secondary cable conductor is bare copper, class 5 (IEC 60228). The core insulation is a special EPR compound. The outer sheath is a halogen free TPR compound (IEC60754-2/ EN 50267-2-3). The operating voltage is 0.6/1kV, with a temperature range of -40 up to +120ºC. The short-circuited temperature is 300ºC and the bending radius 5xD. Please see table below.

Efla Type Diameter over insu- Outer dia- Max. conductor resis- Weight approx lation approx. (mm) meter (mm) tance at �0°C (ohm/km) (kg/km)2 x 2.5 mm2 3.7 9.7 0.3 7.98 1082 x 4 mm2 4.6 11.7 0.3 4.95 160

KDC503-series,Style 1

KDC503R-series, Style 7

KDC506-series, Style 6

KDC506S-series, Style 6

200°C

Codes: KDCT506 and KDCT506S

Efla TypeKDC50� secondary plug Style �KDC50� secondary receptacle Style �KDC50� secondary plug Style �KDC50�R secondary receptacle Style �KDC506 secondary plug Style 6KDC506S secondary plug Style 6KDCT506 secondary plug Style 6 (PTFE)KDC508 secondary receptacle Style 8

Cable length Standard Customized lengths lengths �0 (cm) x (cm) 60 (cm) Examples: �00 (cm) 5 = 5 (cm) �50 (cm) �0 = �0 (cm) �00 = �00 (cm) �000 = �000 (cm)

KDC501 . 2 . 100Ordering information

Cable cross section

� �,5 mm�

� �,5 mm�

4 4 mm�

or

Page 12: CONECTORI TRAFO SEPARATIE

Efla ��

Accessories

Prefabricated extension primary leads

• KDCE510.x.x: Extension cable with a plug and recep-tacle. Connectors as above.

Packing

The prefabricated primary leads with connectors are packed in recyclable cartons.

KDCA.P2R

In some cases, it is possible to use two loads after one AGL series transformer, the KDCA.P2R being designed for this purpose.Distance between connectors is approx. 20 cm.

Materials: Both of the above mentioned products are made by assembling prefabricated products in combination. Please see page 14 for material information.

KDCA.2PR

If the load supplied by standard AGL series transformers is insufficient, it is possible to use two AGL series transformers connected through KDCA.2PR.

Note: When the secondary circuit is earthed, only one of the transformers can have the earthing option. Otherwise, the secondary circuit will short circuit. Distance between connectors is approx. 20 cm.

Prefabricated Unscreened Primary Leads

Our unscreened primary cables comprise a TPE insulated one core cable with a bare copper conductor (19 strands/min 6 mm2).These cables are manufactured in accordance with the specifications FAA L-824 (MIL-C-3432 or ICEA S-66-524) or MIL-C-4921, in general.Nominal voltage is 5.000 V.Prefabricated, molded primary leads, with the desired cable length• Molded on AWG 8 (8.3 mm2) or 6 mm2, 5 kV cable• KDCP510.x.x: the plug connector is FAA L-823 Style 2• KDCR510.x.x: the receptacle is FAA L-823 Style 9• With KDCP510 and KDCR510, the other cable end is freeThe cable length is given in centimeters as a suffix in the article number, KDC 510.8.xx. (for example, KDCP510.8.60 is a Style 2 connector with a 60 cm lead)

Secondary Circuit Y -connectors

Secondary short circuiting connector

KDC506.SHORTThis connector is designed for the short circuiting secondary side of an unused AGLST, almost eliminating the impedance of the secondary side. The connector also has a totally watertight cap.Current rating: 20A, Voltage rating: 600V

KDCA.2PR KDCA.P2R

Page 13: CONECTORI TRAFO SEPARATIE

Efla ��

Voltage Transformers for Parallel Circuits

KDVS.END KDCVO1 KDCV.P2R

Efla Type DescriptionKDCVO1 End caps for KRV -seriesKDCV.P2R Distribution connector for KRVS -seriesKDVS.END End cap for KRVS -series

Parallel transformers are designed to be connected to a normal line voltage (for example, ��0Vac).

Transformers are manufactured to supply a certain voltage in a secondary side. Normally, the voltages are received from standard 6.6 A bulbs or from �� V bulbs.

Possible connection methods involve using one core cable (KRV-type) or two core cable (KRVS-type).

The standard primary voltage is ��0 Vac, the max current rating �0 A and the frequency 50/60 Hz.

KRV transformers have two primary leads, of 0.6 m in length, with a T-type connector which has a FAA interface L-823, a style 2 Plug, and the other end with a FAA823, style 9 receptacle.

The secondary lead is 1.2 m in length, cable type 2 x 2.5 mm2, 0.6kV with a receptacle FAA L823, style 7.

KRV transformers are installed using Efla’s standard KD510 series con-nector kits (see page 4) or prefabricated unscreened leads and extension cords (see page 11). End Caps (KDCVO1) are used at the end of the circuit.

KRV transformers are installed using Efla’s standard KD501 and KD502 series connector kits (see page 6) or prefabricated secondary leads and extension cords (see page 10 and 11). End Cap (KDVS.END) is used at the end of the circuit.

KRVS uses a standard FAA secondary connector for both incoming and outgoing interfaces. The primary lead length is 0.6 m and it has a style 1 connector. The secondary lead length is 1.2 m and it is equipped with a FAA L-823 style 7 connector.

Each transformer can be connected using a prefabricated distribution connector assembly, KDCV.P2R.

Efla Type Efla Type Primary Voltage Secondary Voltage Secondary PowerKRV530 KRVS530 230V 6.8V 45/50WKRV540 KRVS540 230V 15.2V 100WKRV550 KRVS550 230V 30.2V 200W

Technical specification:

Connecting accessories:

Page 14: CONECTORI TRAFO SEPARATIE

Efla �4

Materials

Environmental Policy

Efla Oy’s environmental policy seeks both to minimize the environmental impact of the company’s activities and improve the firm’s long-term competitiveness by anticipating requirements for environmental protection set by customers and the authorities.Responsible care for environmental, health, safety and quality issues forms an inseparable part of Efla’s policy. We constantly strive to improve our capabilities.

Efla’s products are manufactured with the best, economically available technology.

Manufacturing and design

Efla also offers tailored products and components for various customers globally, focusing on designs with a variety of performance features to provide the optimum solution. Quality is based on skilled labor and modern production control. Efla Oy has been certified with the 9001 (2000) Managing System and 14001 (2004) Environmental System.

Materials Encapsulation

Thermoplastic elastomer (TPE) is a modern engineering material with excellent electrical and mechanical properties and good chemical resistance to the chemicals used at airfields. TPE also has very good resistance to weathering, its insulation withstanding UV-radiation and ozone exposure. The material is also resistant to the effects of temperature (below 135ºC).Our experience lies in all classes of TPEs over a wide range of applications specially designed for airfield lighting solutions. Due to close cooperation with global suppliers, Efla Oy always uses the newest technology. Efla Oy has been molding Thermoplastic Elasto-mers (TPEs) for almost 30 years.

Pins and Sockets

Tin-plated copper or brass for the contact parts, while the socket is supplied with a copper beryllium sleeve-type spring, ensuring adequate contact pressure.

RoHS

According to EU directive No 2002/95/EC, the use of lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls and polybrominated diphenyl ethers (hereinafter Restricted Materials) is restricted or prohibited in electrical and electronic equipment.Based on the declarations of our suppliers and the fact that Efla does not add restricted materials during the manufacturing pro-cess, or the materials used are below the limits proposed by the technical adaptation committee of the EU, we can declare that all of our products such as insulation materials, metal parts including primary and secondary options, connectors and AGL trans-formers are designed and manufactured according to the EU directive. Please contact the factory if a declaration of conformity is required.

Packing material

The connectors are packed in recyclable cartons. Each connector kit is individually packed in a low density polyethylene (LDPE) plastic bag. ISPM15, International Phytosanitary Standard for Wood.

Page 15: CONECTORI TRAFO SEPARATIE

Efla �5

Certificates

MAK 262 MAK 263 MAK 264

FAA L-823, FAA L-830 and FAA L-831

ISO 9001 ISO 14001 Factory certificate

IEC 61823

PROGRAM ADMINISTRATOR DEPARTMENT ALECP INTERTEKETL SEMKO Division 3933 U.S. ROUTE 11 CORTLAND, NY 13045-0950

ORIGINAL ISSUE DATE: August 9, 2007

Recertification due: July 2010

An Activity Sponsored and Administered by Intertek

EFLA OY Sepantie 4 07230 Monninkyla, Finland

AIRPORT LIGHTING EQUIPMENT

CERTIFICATION PROGRAM

CERTIFICATE OF CONFORMANCE

The product described below is hereby approved for listing in the next issue of the Federal Aviation Administration (FAA) Advisory Circular (AC) 150/5345-53, Appendix 3 Addendum "Airport Lighting Equipment Certification Program. The approval is based on successful completion of tests in accordance with the specifications listed in, and the requirements for approval described in the Advisory Circular, and the reporting to the Program Administrator the results of such tests, accompanied by related documents by an Intertek recognized testing laboratory. The certification is not valid for a product modified with non-OEM replacement parts or non-production components.

L-823 – Connectors, Cable (AC 150/5345-26C)

Manufacturer Type Class Style Manufacturer's Catalog Number

Efla Oy IIII

BB

512

KD501KD502

1. This Equipment requires continuing validation in accordance with the requirements of AC 150/5345-53, and the Intertek Airport Lighting Equipment Certification Program.

2. Product tested and Report issued by: Helsinki University of Technology; DTL

(A) Report No: 2202hv57; 073313H (B) Date of Report: 7/2002; 4/2003

Approved for Certification by:

David C. Edwards, Program Administrator

NOTE: PLEASE REVIEW, AND ADVISE ADMINISTRATOR AT INTERTEK IMMEDIATELY IF DATA, AS SHOWN, NEED TO BE CORRECTED.

Date: August 9, 2007

Form AL-3 1/2006

Page 16: CONECTORI TRAFO SEPARATIE

Efla �6

Some reference countries