Page 1: CONDENSATE CHAMBERS / SEAL POTS - Technical …technicalspecialties.net/store/secure/uploads/TechLine-CONDENSATE... · Condensate Chambers/Pots: Condensate Chambers are used to collect

...Supporting Future Industry Today

CONDENSATE CHAMBERS / SEAL POTS

Page 2: CONDENSATE CHAMBERS / SEAL POTS - Technical …technicalspecialties.net/store/secure/uploads/TechLine-CONDENSATE... · Condensate Chambers/Pots: Condensate Chambers are used to collect

Condensate Chambers/Pots: Condensate Chambers areused to collect and accumulate condensate and extrinsicparticles. Condensate chambers aid in protecting delicateinstruments with smaller orifices from becoming damagedor clogged by foreign debris. The bottom connection isused as a drain port to remove condensate. Condensatechambers can also be used to cool very high temperatureliquids.

Seal Pots : Seal pots are used to provide a liquid sealbetween the process instrument and gases such as steam.Its function is to keep the liquid level constant in theimpulse tubes (sensing lines), while preventing stem orcorrosive liquids from reaching the instrument.

Typical Applications

Techline Mfg. Condensate Chambers & Seal Pots arefabricated from seamless pipe. A variety of materials andwall thicknesses are available to meet a customer's designpressure and temperature.

Standard stock chambers are 3” pipe, 12” long with three(3) ½” FNPT connections in Schedule 80 316 StainlessSteel or Carbon Steel. Expedited delivery is available fornon-stock chambers.

All chambers are hydro pressure tested and certified priorto shipping. X-Ray & Dye-Pen testing are available uponrequest.

Typical Chamber Dimensions

2

1/3 LENGTHOF CHAMBER(TYP.)

½” FNPT3000#CONNECTIONS(TYP.)

ASME StandardsTechLine manufactures our vessels to ASME standards. Ifan ASME U or S stamp is required, please request onquote and we can provide pricing according to your specificneed.

1-800-395-3369 www.techlinemfg.com

TechLine Condensate Chambers / Seal Pots

Page 3: CONDENSATE CHAMBERS / SEAL POTS - Technical …technicalspecialties.net/store/secure/uploads/TechLine-CONDENSATE... · Condensate Chambers/Pots: Condensate Chambers are used to collect

Basic Part:TechLine Drip

Size of Part: (2”, 3”, 4”, 6”,etc.)

Wall Thickness of Pipe:(Standard S/40=SExtra Heavy S/80=XHSchedule 100=S/160Extra Extra Heavy=XXH

Material Finish:Carbon Steel=CS304 SS=SS316 SS=316SSChrome 11=P11

Chrome P21=P21Chrome P91=P91Hastelloy=HCGalvanized=GV

Connection Style (Code):Female NPT=FSocket Weld=SSpecial=X

Connections Size Code:1/4”=43/8”=61/2”=8

3/4”=121”=16Special=X

Length of Chamber fromEnd Cap to End Cap:(6”, 7”, 8”, 9”, 10”, 11”, etc.)

Port Connection:

A B C D

E F G

Example: - - - - - -TLDP 3 12 CS XH F 8

3

L

A

O.D.

TechLine Condensate Chambers / Seal Pots

1-800-395-3369 www.techlinemfg.com

Page 4: CONDENSATE CHAMBERS / SEAL POTS - Technical …technicalspecialties.net/store/secure/uploads/TechLine-CONDENSATE... · Condensate Chambers/Pots: Condensate Chambers are used to collect

Techline Mfg. August 2013

Techline Manufacturing

30516 Sgt E.I. Boots Thomas Drive • Spanish Fort, AL 36527

Toll Free: 1-800-395-3369 • Local 251-380-7300 • Fax 251-380-7301