company pro˜le - high energy electricnangluongcao.com/upload/tailieu/catalog-taian.pdf · control...

12

Upload: phamtuyen

Post on 09-May-2019

214 views

Category:

Documents


0 download

TRANSCRIPT

Company Pro�leTaian-Jaya Electric was established since year 1988 with a total investment of over 1 Million. Our company is located in Shah Alam, Malaysia and we are proud to be associated with TECO Group of companies. We had been servicing the Malaysia and International market with our quality electrical products for uses in the residential, commercial and industrial needs. Taian-Jaya Electric emphasised on high Quality Control Management System according to ISO9001. Our quality control management system was �rst used in the manufacturing of our D.O.L Starter and we had over 25 years of experienced in the manufacturing �elds.

Taian-Jaya Electric been an expert manufacturer in electrical products and with vast experienced in the international market, had since expanded our chain of electrical products supply for AC/DC Magnetic Contactors, Thermal Overload Relays, Molded Case Circuit Breakers, Residual Current Circuit Breakers, Miniature Circuit Breakers and others.

Supported by e�ective marketing our sales networking is now throughout Asia, South-East Asia and the Middle-East. Recently we had also expanded our business to Hong Kong, Taiwan, Indonesia, Thailand, Myammar, Vietnam, Bangladesh, Iraq, Pakistan and Sri Lanka.

Our Company Quality Policy“ SATISFYING CUSTOMERS NEEDS ” Striving to satisfy our customers by providing suitable products and good services throughout every sta� and with the concept of “ THE NEXT PROCESS IS OUR CUSTOMER ”.

Takes pride in the performance of Total Quality Assurance.

Product Certi�cationOur company and products are certi�cated with ISO 9001, SIRIM (Malaysia Standard and Quality Management System) and CB scheme, which complied to MS IEC 60947-4-1: 2005 (for Starter), MS IEC 60947-4-1: 1996 (for Contactor), MS IEC 60898-1: 2003 (for MCB), MS IEC 61008-2-1: 2003 (for RCCB) and MS IEC 60947-2 (for MCCB) and also comply with the standard of Energy Commission and Public Works Department of Malaysia as well.

Our ProductsWe are the manufacturer of: AC Magnetic Contactor Reversing Magnetic Contactor Thermal Overload Relay Auxiliary Contact Block Direct Online Motor Starter Star Delta Starter

Miniature Circuit Breakers Residual Current Circuit Breakers Molded Case Circuit Breakers Safety Switch Distribution Board Isolator Switch

1/8

Specifications and availabilitysubject to changes

2/8

Frame size ( AF )

Type

Number of Poles

Rated current ( A )At ambient temperature 40

Rated insulation voltage (V)

Rated breaklng capacity (kA)

GB 14048.2IEC 60947-2EN 60947-2

Dimensions (mm)

a

b

c

d

aa

bb

AC 400V

AC 230V

Weight (kg)

Features

Automatic tripping device

Trip button

ON/OFF indicator

Connections

Connections

Accessories ( option )

Inte

rnal

ly m

ount

edE

xter

nally

mou

nted

Shunt trip SHT

Under voltage trip UVT

Auxiliary switch AUX

Alarm switch ALT

Alarm+Auxiliary switch ALT + AUX

Electrical operation mechanics CD

Handles CS

Extension handle EHA

Terminal cover XPR

Interpole barrier TQQ

Attached flat bar TBB

ON

OFF

* : Special Request

Ope

ratio

npe

rform

ance

63 100 225 400 630 800 1250 1600

TJ-63L TJ-100L TJ-225L TJ-400L TJ-630M TJ-800M TJ-1250M TJ-1600M

3*/4 3*/ 4 3*/ 4 3*/ 4 3*/ 4 3* 3 3

6, 10, 16, 20,

25, 32, 40, 50,

63

10, 16, 20, 25,

32, 40, 50, 63,

80, 100

125, 160, 180,

200, 225

250, 315, 350,

400 500, 630 700, 800 1000, 1250 1600

500 800 800 800 800 800 800 800

76 92 107 150 182 210 210 210

135 150 165 257 270 280 330 330

74 68 86 105 110 106 138 138

92 86 110 115 160 145 190 190

25 30 35 44 58 70 - -

117 129 126 194 200 243 - -

15/10 15/10 30/25 35/25 50/35 50/35 85/43 100/50

22/15 25/15 42/35 50/35 85/60 85/60 100/50 125/63

Fixed-thermal and fixed-magnetic

Terminal screw Busbar

1500 1500 1000 1000 1000 1000 1000 1000

8500 8500 7000 4000 4000 4000 4000 4000

Right Right Right Left Left Left Left Left

- - - - - - - -

- - - -

- -

Left Left Left Left Left Left Left Left

Left Right Left Right Left Right Right Right Right Right Right

Left Right Left Right Left Right Right Right Right Right Right

Left Right Left Right Left Right Right Right Right Right Right

dc

b

a

aa

bb

TJ SeriesMolded Case CircuitBreakers (MCCB)

Specifications and availabilitysubject to changes

3/8

TJ SeriesResidual Current CircuitBreakers (RCCB)

Frame Size(AF)

Type

Number of poles

Ambient temperature

Rated Voltage (V)AC

Leakage Acting current

Rated Current (A)

Dimension (mm)

Automatic tripping device

Mount

Weight (kg)

Connections

RCCB

63

RC - 362 RC - 364

2 2 4 4

40 C

240 240 240/415 240/415

10mA/30mA 100mA 10mA/30mA 100mA

0

1A

2A

3A

6A

10A

16A

20A

25A

32A

40A

50A

63A

a

b

c

ca

36 72

82

50

75

Fixed-Thermal and Fixed magnetic

On 35mm DIN rail

0.2 0.2 0.35 0.35

Terminal screw

Note : : Available -: Not Available

Remark : This product is designed specifically for South East Asia

- - - -- - - -- - - -- - - -- - - -- - - -- - - -

- - - -

cac

b

a

Specifications and availabilitysubject to changes

4/8

TJ SeriesMiniature Circuit Breakers(MCB)

Frame Size(AF)Type

Number of poles

Ambient temperature

Rated Voltage (V)AC

Rated Current (A)

Dimension (mm)

Automatic tripping device

MountWeight (kg)

Connections

MCB 6kA

63

TJ63105

MCB 10kA

63TJ63106

Rated Breaking Capacity (kA)

IEC 60947-2Icu

“c” Curve “c” Curve

1

40 C

240/415 240/415 240/415 240/415 240/415 240/415

6kA 6kA 6kA 10kA 10kA 10kA6kA 6kA 6kA 10kA 10kA 10kA

40 C

2 3 1 2 3

0 0

AC 415VAC 240V

1A

2A

3A

6A

10A

16A

20A

25A

32A

40A

50A

63A

a

b

c

ca

18 36 54 16 36 54

82 82

50 50

75 75

Fixed Themal and Fixed magnetic Fixed Themal and Fixed magnetic

On 35mm DIN rail On 35mm DIN rail

0.1 0.2 0.3 0.1 0.2 0.3

Terminal screw Terminal screw

Note : : Available -: Not Available

Remark : This product is designed specifically for South East Asia

cac

b

a

Specifications and availabilitysubject to changes

Dimension

4P:72+453P+N: 54+453P: 54+362P: 36+271P: 1827

5/8

TJ Series Residual Current Operated Circuit BreakersWith Over-current Protection (RCBO)

The Over-current Protection Property

In I n

I n 2I n 5I n(A)6-63

30 2 C

-5~+40 C

Ambienttemperature

Carried out immediatelyafter previous test

Testcurrent

ExpectedresultInitial status

Cold position

Cold position

Cold position

Cold positionCold positionCold positionCold positionCold positionCold position

Test time Note

Type BType BType CType CType DType D

-

-

Current smoothly rises tospecified value within 5s

Non-release

Non-release

Non-release

Non-release

Release

Release

Release

Release

Release

Release

0.03, 0.05, 0.1, 0.3 0.1

1.13ln

1.45ln

2.55ln

2.55ln

3ln5ln5ln10ln10ln20ln

t 1h

t 1h

t 0.1s

t 0.1s

1s t 60s(ln 32A)

1s t 120s(ln 32A)

t 0.1s

0.06 0.04 0.04

5,10,20,50,100,200,500 (A)

0.04

(A)Breaking time(s) when equals to rating following

l t ba

TJ-RCBO-63 is applicable to a line of AC 50/60Hz, rated voltage 240V for single pole two-wire, 2-pole or 415V for 3-pole, 3-pole 4-wire, 4-pole and rated current up to 40A. It can protect the line and motor from overload and short circuit. It can also be used for infrequent line conversion and infrequent motor start. It conforms with the standards of IEC61009.

t 0.1s

t 0.1st 0.1s

Main Technical Parameter

Applicable Conducting Wire

Residual Current Breaking Time

Frame Size (AF)Pole

Rated current (A)Rated voltage (V)

Rated short circuit breaking capacity lcn(kA)Rated residual making/breaking capacity l m(A)

Rated residual action current l n(A)

Rated residual non-action current l no(A)

RCBO-631P+N, 2P 3P, 3P+N, 4P

6,10,16,20,25,32,40,50,63240 415

6-32A :6 / 40-63: 4.52000

0.03,0.05,0.1,0.3

0.5l n

Rated current (A)Norminal cross section of wire mm

1-6A 10A 16,20A 25A 32A 40,50A 63A1 1.5 2.5 4 6 10 16

Specifications and availabilitysubject to changes

6/8

TJ SeriesDirect On LineMagnetic Starters(DOL Magnetic Starters)

RATED CAPACITY AC 3

1 O 240V 3 O 415VT.O.R.RATEDAMPS

T.O.R.RATEDAMPS

HP KW HP KW

STEELENCLOSURE

ABSENCLOSURE

IP-66 ABSENCLOSURE

TYPE TYPE TYPE

0.18

0.37

0.55

0.75

0.18

0.37

0.55

0.75

1.5

2.2

3

3.7

H-16LB

H-16LB

H-18LB

H-20LB

H-25LB

HKFB-16LB

HKFB-16LB

H-11LB HP-11LB HKFB-16LB

HP-16LB

HP-16LB

HP-T 11LB

HP-T 16LB

3

4

5

7

1.5

2

3

5

2

2.5

1.1

1.5

2.2

3.7

1.5

2.2

10

13

15

26

13

15

7.5

10

15

20

5.5

7.5

11

15

13

15

20

26

1 1

1.5-2

3

4

5

TJ SeriesDirect On LineMagnetic Starters(DOL Magnetic Starters)

Specifications and availabilitysubject to changes

7/8

Combination Tables

DEALER :