company profile

24
Company Profile

Upload: harish-menon

Post on 16-Feb-2016

18 views

Category:

Documents


0 download

DESCRIPTION

CC

TRANSCRIPT

Page 1: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

1

Company Profi le

Page 2: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

2

Preface

True-out this company profi le we hope to give you a good impression of our company and products.

Thanking you in advance for taking the time to read our company profi le and your interest in our products.We hope to be of any assistance to you in the nearby future.

If you have any questions regarding our products please do not hesitate to contact us.

Kind regards,

Lars WiersmaExport Manager

Page 3: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

3

Table of content

Subject Page

Preface 2

Table of content 3

Company introduction Mission statement 4 Facts & fi gures 4

Company vision 5

Introduction HC Groep 6

Profi le 7

Climate laboratory, Product development & Acoustic reverberation room 8 - 10

Product overview 11 - 14

Induction VAV, the optimum indoor climate & energy effi cient system 15

Combined knowledge VAV & Controls 16

References 17 - 21

Distributor list 22 - 23

HC Barcol-Air continuously aspires to further optimise the construction and the quality of all products. HC Barcol-Air preserve themselves the right to carry out modifi cations in product specifi cations without notice or obligation. S.E. & O.

© Copyright Barcol-Air B.V. 2008

Nothing from this publication may be multiplied and/or made public by means of printing, photocopy, microfi lm or in whatever manner, without preceding written authorisation of HC Barcol-Air.

Page 4: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

4

Company introduction

Mission statement

HC Barcol-air is specialized in designing, developing and realizing a perfect thermal indoor climate. All in com-pliance with the demands of the client, consultant and architect. For small and large projects, in standard and specifi c circumstances, from single products to complete installations, including design and climate laboratory test according to ISO standards.

It is HC Barcol-Air’s goal to create an indoor climate, which offers an optimum in terms of comfort. Always and everywhere with a minimum of energy use.

Facts & Figures

Turnover HC Groep > 40 million euro and • > 150 employees2 products groups Air distribution & Controls• > 60 employees• > 70 years experience in indoor climate / thermal • comfortCombined knowledge of Air distribution & Controls• Added value by technical know-how• R&D departments, 6 engineers with 100 years com- • bined experienceFull scale climate room, > 250 tests• “ Specials”, > 2.500 special developed products• > 200 large BMS projects•

• > 10.000 Air Distribution projectsProjects in > 50 countries with 35 distributors •

Page 5: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

5

Company vision

Introduction

Designing and developing products and systems to cre-ate and control the environment in commercial buildings using the minimum energy and providing with optimal comfort.

HC Barcol-Air is a domestic market leader with good international presence who sets trends trough technical knowledge and excellent broad product offering.

The name HC Barcol-Air must be synonym for thermal comfort and quality.

The “One Source, One Responsibility” concept combines a substantial product & system portfolio, know-how, ser-vice and experience to one effi cient centre of excellence. All components are designed to form complete integrated systems, which guarantee perfect operating and perfor-ming HVAC installations.

Specialist in Air distribution products

HC Barcol-Air is manufacturer and supplier of a com-plete range of high quality Barber Colman air distribution products and systems which can be supplied with a short delivery time mainly from stock. Together with a range of standard products HC Barcol-Air has all facilities (R&D department & climate laboratory) to develop, test and ma-nufacture specifi c products and systems and to provide a total and best comfort solution.

Extensive know-how and cooperation with other company product groups (controls, chilled ceiling and service) re-sults in the best possible solution for every HVAC appli-cation, with project specifi c designs if needed. HC Barcol-Air likes to implicate all its know-how and experience in the early stage of the project, to be able to act as partner in designing the best possible installation.Clients, consultants and contractors can count on the technical support of our sales engineers, supported by our R&D team and climate laboratory facilities.

History

The origin dates back to 1932, when Barber Colman star-ted de develop Air Distribution, products and controls.

Timeline:

1900 BARBER-COLMAN Company (USA)

1935 Air Distribution Products Division

1982 BARCOL-AIR (100% subsidiary of Barber-Colman)

1987 Barber-Colman purchased by SIEBE Plc

1998 SIEBE + BTR = Invensys

Current Situation

On April 1st , 2006 Barcol-Air B.V. was taken over by theHC Groep, a market leader in the Netherlands, who can offer a total comfort solution including design, testing and commissioning.

One Source, One Responsibility

Page 6: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

6

Introduction HC Groep

Climate ceilings

Metal ceilingsIndustrial ceilingsPlaster ceilingsAir climate ceilings

Air handling units

9 seriesOwn coilsTB1/T1Eurovent certifi ed

Car parking ventilation

Ventilation systemsCO/LPG detectionFire detectionSwitchboard

Chillers / WP

Air curtainsRoof fansCCU / Dry coolersVentilation concepts

Car parking ventilation

Ventilation systemsCO detectionFire detectionSwitchboard

Air Distribution & Controls

Grilles & DiffusersCAV & VAV UnitsMeasuring and control stationsBuilding Management Systems

Assembly & Metal treatment

Integral supplier

Comfort, safety and an optimal living- and working environment – the main goals for the HC Groep as an integral supplier. Either climate ceilings, ventilation, air treatment- or climate control, you will fi nd the perfect solution within the HC Groep.

Versatile, high quality standards, fl exible and customer-minded. Because of these high standards, consultants, architects and contractors have been calling upon the companies within the HC Groep.

Unity in diversity

The HC Groep consist of seven companies, each of them fully aware of the latest market requirements and in direct contact with business related partners.

The following overview pictures the different companies:

Combined strength

The companies united, the excellent service and the fi nancially strong HC Groep’s accommodated attendan-ce, result in a powerful unit.

A unity, which pays close attention to the wishes and needs of the business. By operating united, the compa-nies can combine their services like never done before, offering you only the best of the business on a daily basis.

The HC Groep combines decades of knowledge and experience. We are eager to share this knowledge with you. On top of this, we have our own climate room, in which full scale mock-ups can be constructed. A great deal of diffi culties, which can occur during construction and/or commissioning, can be prevented by performing climate room tests. The quality of products supplied by the HC Groep are guaranteed by a wide range of certi-fi cations and attests of independent testing authorities. Thus consolidating the reliability of the products.

Page 7: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

7

Profi le

Organization

HC Barcol-Air consist of two main divisions: Air Distribution and Controls

Air Distribution Product: Development • Production• Sales ( domestic & export)• Support•

Controls products/BMS:• Engineering• Supply and Installalation• Wiring and panels• Software & Commissioning

Both are supported by the service department:• Call-out service• Service contracts• Refurbishment & up-grades• Judgment thermal comfort

End of Warranty•

HC Barcol- Air Organization Chart

Climate room

OrganizationManagement

Marketing

Internal OperationsControlsAir Distribution

R&D

Financial Administration

DevelopmentProductionSales Domestic

ExportSupport

Domestic SalesProject managementSupply & InstallationWiring & PanelsSoftware & CommissioningService & support

Call-outContractsRefurbishment UpgradesEnd of Warranty

Order handlingProcurementLogisticsProductionWarehouseQuality

Page 8: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

8

Climate laboratory & Product development

Introduction

Recently,HC Barcol-Air has built a reverberation room for sound testing of products and systems. This enables Barcol-Air to test products and systems in the sphere of thermal indoor climate and sound production and absorp-tion.

Climate laboratory

The purpose of a full-scale climate laboratory test is to give the principal, designer and consultant maximum security about the installation’s design, in an early stage. Especially when the design is completely new, not often used or when the building has specifi c characteristics, a climate laboratory test can prevent a lot of problems du-ring construction or even after commissioning.

HC Barcol-Air’s climate room in Purmerend (Netherlands) has a maximum fl oor space of approx. 8 x 8 meter with fl exible positional walls and ceiling up to a height of 3.3 meter . To perform full-scale tests, the room is built with exact (actual) dimensions. The climate façade simulates the outdoor conditions and can be cooled to simulate win-ter conditions and heated to simulate summer conditions. Uniquely this test room has two climate facades from bottom to ceiling, which enables to test also (complica-ted) corner rooms.

Mock-ups are not only built with actual dimensions but also façade, ceiling, furniture, fl oor covering, convectors and lightning can be built according to project specifi -cation. There is also the possibility of building special application rooms like hospital rooms, dealing rooms, laboratories and so on.

In the climate laboratory of HC Barcol-Air static tests are performed. This means that thermal conditions in- and outside the mock-up are equally; there is no transmission loss via walls, fl oor or ceiling.

Data Acquisition System

All measuring data is collected and processed with a, by “labVIEW®” supported, automatic “Data Acquisition System”. “labVIEW®” is a software program of National Instruments for virtual instrumentation.

Measuring robot

The most important part of the measuring system, in the actual size built mock-up, is the automatic moving measuring robot with accurate air temperature and velo-city sensors. The height of the measuring sensors is ac-cording NEN-ISO standards 0,1 – 0,6 – 1,1 and 1,7 meter above the fl oor. These heights represent ankles, bottom, trunk and head of the human body. The robot measures the area from fl oor to ceiling and from front to back of the test room.Extra sensors are mounted on the robot on other heights and in different measuring areas to detect possible ir-regularities (for instance asymmetry) of the air pattern. Extra sensors are also mounted 5 cm below the ceiling to check the air pattern of the supply diffusers.

Fixed sensors

Besides the sensors on the measuring robot, there are also sensors mounted on fi xed places for primary air tem-perature, supply air temperature, air volume, reference room temperature, windowpane surface temperature (in- and outside) and surrounding temperature.

Accuracy air velocity and temperature sensors

The accuracy and response time of all sensors apply to the standards set in the ISO 7726 (1998). The tempe-rature sensors have a relative accuracy of 0,1 ºC and a time constant of 2,3 second. The air velocity sensors have an accuracy of 0,014 m/s and a time constant of 0,03 second.

Page 9: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

9

Standards

The climate laboratory meets the most recent standards NEN-ISO 7726 and NEN-ISO 7730. The results of measurements and check of the air stream pattern and distribution is generally checked against DIN 1946, part 2. The calculated comfort parameters are checked against NEN-ISO 7730. It is also possible to check theclimate laboratory test results and comfort parametersaccording to specifi c project demands.

Presentation test results

Air temperature and velocity measuring results are pre-sented in both graphical and table format. The data acquisition system has a unique calculation module to present real time not only air temperature and velocity butalso the PMV (Predicted Mean Vote), PPD (PercentagePeople Dissatisfi ed) and DR (Draft Rate). All displayed values are average values per 100 seconds.

The purpose of a full-scale climate laboratory test is to give the principal, designer and consultant maximum security about the installation’s design, in an early stage. Especially when the design is completely new and not used before.

Reporting

After the climate laboratory test has been fi nished and discussed with the principal, a complete and fi nal report is made. This report describes in detail under which conditions and how the test has been performed. The measuring results and conclusion are a written proof of the performance of the tested installation concept. Byrecording accurately all data and results, the test can bereproduced. Product development besides testing pro-ject specifi c installation concepts, the climate laboratory is used for product and system research and deve-lopment. One of HC Barcol-Air’s main competences isproject specifi c design of air distribution components or modifi cation of standard products. These new product can be tested easily to check whether they apply to the set standards.

Climate laboratory & Product development

Page 10: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

10

Acoustic reverberation room

Introduction

HC Barcol-Air has built a reverberation room for pre-design sound testing of products and systems. This ena-bles Barcol-Air to test products and systems for thermal indoor climate as well as sound production and absorp-tion.

Acoustic performance

The test at HC Barcol-Air is executed in a reverberation room (not certifi ed), which has a volume of 65 m³ and a reverberation time of 2.2 - 2.5 seconds.Measurements are being executed through a calibrated sound meter fabricated by Delta Ohm type HD2010, which can determine the reverberation time for each room/test set-up individually.

Measurement of inlet sound

The CAV/FCU will be set-up inside the reverberation room with the outlet connected to the opening towards the adjacent small room. This way a combination of the inlet sound together with the radiated sound will be measured.

Measurement of outlet sound

In this case the CAV/FCU will be placed in the small adjacent room with the outlet connected towards the reverberation room. Only discharge sound levels will be measured in this case.

Acoustic calculations

The measured sound levels will be corrected with the background noise and the reverberation time of the room, which will also be measured both individually.The measured sound power levels for the mid ranges of frequency band 125 – 8,000 Hz and NR levels will be presented in table and graph form.

432

200

399

600

H=2,90m

H=2,70m

Reverberation room

Opening in wall max. 110x150cm

(BxH)

Page 11: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

11

Product overview

Type NA/NB Round single duct VAV terminal

Pressure independent • For individual room temperature control• Model 100 to 400• Single or double wall construction• Compact• Low leakage damper• High accurate airfl ow sensor• Quiet in operation•

Type NK/NL Rectangular single duct VAV terminal

Pressure independent • For individual room temperature control• Size 200x150 to 2000x1000mm• Single or double wall construction• 350 mm installation length• Low leakage damper• High accurate airfl ow sensor• Quiet in operation•

Type NS VAV terminal with integrated sound- attenuator

Pressure independent • For low noise requirements in high pressure or • high velocity systems Model 100 to 400• Compact in size• Low leakage damper• High accurate airfl ow sensor • Very quiet in operation •

Type NV Induction VAV terminal

Pressure independent • For comfortable air distribution in systems with • high load variation Model 100 to 400• Low leakage damper• High accurate airfl ow sensor• Very quiet in operation• Provides savings in energy•

VAV units

Page 12: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

12

Product overview

Type NZ Dual duct VAV/CAV terminals

Pressure independent • For individual room temperature control• Model 100 to 400• Low leakage damper• High accurate airfl ow sensor• Constant airfl ow to the room• Quiet in operation•

Type FCU Fan coil unit

Horizontal or vertical application• With or without cabinet• Inlet sound attenuator with fresh air connection • optional Multiple circular outlets section optional• Extended and insulated drip tray• 2 pipe change-over or 4-pipe system• Electric heating coil optional •

Type AIR-FIT® Active Chilled Beam

Using high graded materials• Minimum istallation space• High cooling and heating capacity• Possibility to vary primary air volume•

VAV, Fan coil units & Chilled Beams

Page 13: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

13

Product overview

Type VBG High capacity, circular swirl diffuser with fully adjustable air pattern

Type CLW Linear slot diffuser, adjustable air pattern

Type CSV Linear Jet Flo

Type PBD Square perforated ceiling diffuser

Diffusers & Grilles

Page 14: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

14

Product overview

Type GFA Grille, high induction

Type GKB Grille, aluminuim construction single and double defl ection

Type TBW Wall and Window grille, linear fi xed core, 0° / 15° deflection

Type GCJ High capacity Jet-Flo diffuser adjustable elements

Diffusers & Grilles

Page 15: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

15

Introduction

Conventional VAV systems have proven in the past to be very effi cient in providing an optimal indoor climate. However the latest standard and requirements for energy effi ciency and human comfort make it more and more diffi cult to design conventional VAV systems in new buildings. From an energy point of view, the minimum air volume could cause “cold air dumping” and lack of air movement in the room, resulting in occupants discomfort which results in less productivity.

Benefi ts of induction VAV

Up to 100W/m• 2, without loosing comfortCooling, heating and ventilation done by one unit• Perfect fl ush of the room, also with partial loads, no • cold air dumpingLittle space required; small size boxes, relative (30%) • small AHU’s and ductwork due to 10-12°C primary airStandard diffusers with reliable performance can be • usedNo humidity problems with reliable performance can • be usedLow noise level; terminal unit including sound attenu-• atorAutomatic air fl ow adjustment when loads are chan-• ging1.25 mm galvanized steel casing prevents breakout • noise and reduces risk torsion during installationFlo-Cross air volume sensor, fl ow direction indepen-• dent, centre averaging, amplifi ed signal and very accurate ( +/- 2.5%)Possibility to pre-fi t and pre-calibrate the VAV con-• trols ( plug and play)Low maintenance, no fan, no fi lter, no fi ns in recircu-• lated air

Induction VAV, the optimum indoor climate & energy effi cient system

0 50 100min.

q1 (%)q 3

(%)

0

50

100

q1

q2

q3

Page 16: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

16

VAV box with Controls

Compatible with any BMS System

• BACnet® ( BTL Certifi ed)

• LonMark® (LON)

Plug & Play works with any 3rd party BMS• Pre-fi tted• Pre-wired• Pre-calibrated• Pre-tested

Benefi ts of VAV boxes with pre-fi tted controls• Single sourse• Single responsibility• No coordination• No delays in deliveries• Single service responsibility• Open protocol:LonMark®/BACnet®

• Easy integration with BMS

Combined knowledge VAV & Controls

One Source, One Responsibility

Page 17: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

17

Reference projects Europe:UFR de Nantes FranceMontaury FranceHPL Nouvelle Clinique FranceHospital de Meaux, phase II FranceClinique Saint Priest FranceCentre Hospitalier de Cannes FranceNeuro 3D FranceKlinikum Weilmunster GermanyAluminium Factory IcelandPowerstation Hellis Heidi IcelandTCD Comms IrelandDHL Warehouse IrelandComune die Bologna ItalyPalestra Verruchio ItalyEx universita Leon Battista ItalyOspedale di Tricase ItalyShakalin Exxon Mobile RussiaToyota/lexus Showroom SloveniaHarvey Norman Store SloveniaDrapal, Andjelic and Mikec SloveniaPark Hotel Bled SloveniaIndustrial research Industry SwedenSpital Baar Beulach Bauphase 3 SwissSimilason Jona SwissOspedale Civico Lugano SwissOSG Bellinzona Fisioterapia SwissMMM Neuwiesen Winterthur SwissGross Maenendorf SwissCredit Suisse SwissVale Interiors United KingdomUSB Bank, 6th Broadgate United KingdomUKL Wexham Springs United KingdomQueen Alexandria Hospital United KingdomDeutsche Bank Pinnershall United KingdomNortwick Park Hospital United KingdomNomura House London United KingdomMk dons Stadium Ballroom United KingdomHeathrow Air Traffi c Control Tower United KingdomFlourish-Barclays Capital United KingdomFaraday BG Reading United Kingdom338,Euston Road United KingdomBuckinghamshire University United Kingdom123, Buckingham Palace Road United KingdomBroadgate Tower, 201 Bishopsgate United Kingdom55, Bakerstreet United Kingdom200, Aldersgate United Kingdom3rd Hardmann Square United Kingdom31, Gresham Street United Kingdom16, Eastcheap United Kingdom14, Farringdonstreet United KingdomIBM Lakeside Bldg, Portsmouth United KingdomManchester Justice Court United Kingdom Reference projects Africa: New Flight Kitchen-Catering EthiopiaSudapet HQ Sudan

Reference projects Middle East:Marriot Hotel BahrainBahrain City Centre BahrainTrust Insurance Tower BahrainInternational Insurance Tower BahrainFinancial Harbour BahrainFormula 1 circuit BahrainResearch Institute of Petrochemical IranCentral bank of Jordan JordanLand Rover Showroom JordanCooling Industrie JordanIntercontinental Hotel JordanKuwait Oil Tanker Co KuwaitIbis Hotel KuwaitMinistry of Interiors KuwaitQatar University QatarNavigation Tower QatarIntercontinental Hotel QatarScience Technology Park QatarPrince Mohammed University Saudi ArabiaPrivate Palace Musafah United Arab EmiratesMubadala ERWDA Building United Arab EmiratesMinistry of Foreign Affairs United Arab EmiratesIbis en Novotel United Arab EmiratesEmirates Airlines Head Quarter United Arab EmiratesAirport Flower Centre United Arab EmiratesDAFZA Building 7,8,9 United Arab EmiratesCity Hospital United Arab EmiratesBurj Dubai United Arab EmiratesAl Salam Tower United Arab EmiratesEtisalat United Arab Emirates2b+G+3 Offi ce Building United Arab EmiratesStandard Chartered Bank United Arab EmiratesMinistry of Foreign Affairs United Arab EmiratesEmirates Airlines Head Quarter United Arab EmiratesDubai Business Park United Arab Emirates Reference projects Far East:Kun Lun Apartments ChinaMicrosoft phase 3 IndiaMerrillynch IndiaHSBC @ Softzone IndiaShell IndiaGoogle IndiaYahoo IndiaCity Tower PakistanAgaKhan University Hospital PakistanMakro Habib Cash & Carry PakistanYong Xin Pharmaceutical Project SingaporeAbbot Nutrition SingaporeNTU-SPMS Singapore Reference projects Australia: Rhodes Australia66 Waterloo Road AustraliaCitycenter AustraliaKing Street Wharf AustraliaHyundai HQ Australia

Export reference projects 2006-2007

Page 18: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

18

Nomura Bank,London-United Kingdom500x VAV terminals with integrated sound attenuators and elect.heaters

Intercontinental Hotel, Aqaba-Jordan18x VAV terminals + TAC LON controllers

Media City, Dubai-United Arab Emirates1000x Induction VAV terminals, cooling only

Bur Juman Center, Dubai-United Arab Emirates800x High accuracy Flo-Cross air fl ow sensors

Fund Head Quarters, Abu Dhabi-United Arab Emirates400x VAV terminals with sound attenuators

USB Bank-Broadgate,London-United Kingdom150x VAV terminals with integrated sound attenuators and elect.heaters

Page 19: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

19

Neuro 3D, Mulhouse-France20x Laboratory VAV terminals + TAC LON controllers

Heathrow Control Tower, London-United Kingdom16x special Fan coil units with integrated adjustable diffuser + controls

Financial Harbour, Manama-Bahrain1800x Induction VAV terminals with TAC BACnet controllers

Formula 1 circuit, Manama-Bahrain80x VAV terminals, cooling only

Qtel Building, Doha-Qatar800 x Induction VAV + non-induction VAV terminals

Park Hotel, Bled-Slovenia150x Fan coil units, cooling and heating

Page 20: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

20

Hyundai-HQ, Sydney-Australia76x Induction VAV terminals, cooling only

Etisalat, Dubai-United Arab Emirates800x VAV terminals, cooling only

Bishop Square, London-United Kingdom200x CAV terminals, rectangular type + sound attenuators and controls

Gulf Library, Abu Dhabi-United Arab Emirates150x VAV terminals, cooling only

Intercontinental Hotel, Doha-Qatar100 x VAV terminals, cooling only

Klinikum, Weilmunster-Germany16x VAV terminals + TAC LON controllers

Page 21: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

21

2B+G+3 Offi ce Building Health Care City, Dubai-United Arab Emirates100x Induction VAV terminals + TAC LON controllers

Airport Flower Centre, Dubai-United Arab Emirates150x Induction + non-induction VAV terminals, cooling only

Insurance Tower, Manama-Bahrain400x Induction VAV terminals + TAC BACnet controllers

Emaar Business Park, Dubai-United Arab Emirates1800x Induction VAV terminals, cooling only

DAFZA Head Quarters Building + Building 4, 5, 6, 7, 8, 9, Dubai-United Arab Emirates, 4,500 x Pressure Independent VAV terminals

City Hospital, Dubai-United Arab Emirates800x Induction + non-induction VAV terminals + electric heaters

Emaar Business Park, Dubai-United Arab Emirates

Arab Emirates, 4,500 x Pressure Independent VAV terminals

Page 22: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

22

Distributor list

Europe

Reliance Engineering Services Ltd. Nicosia CyprusMWH Barcol-Air Malling DenmarkMWH Barcol-Air France Cergy Pontoise Cedex FranceInvent Technika Kft. Budapest HungriaRafn Jensson Mechanical Engineers Reykjavik IcelandCoolair Ltd. Dublin IrelandContel Automation & Control Ltd. Petach-Tikva IsraelOffi cine Volta S.p.A. Bologna ItalyIntelligent Building Systems Sp. z o.o. Wroclaw PolandAHI Carrier Moscow RussiaVavtar Inženiring d.o.o. Ljubljana SloveniaHiensch Engineering AB Stockholm SwedenMWH Barcol-air AG Stäfa SwitzerlandBarcol-Air UK Ltd. Bath United Kingdom America MWH Barcol-Air USA Santa Clara USA

Page 23: Company Profile

HC Barcol-Air Changes w/o notice or obligation.

23

Distributor list

Europe

Reliance Engineering Services Ltd. Nicosia CyprusMWH Barcol-Air Malling DenmarkMWH Barcol-Air France Cergy Pontoise Cedex FranceInvent Technika Kft. Budapest HungriaRafn Jensson Mechanical Engineers Reykjavik IcelandCoolair Ltd. Dublin IrelandContel Automation & Control Ltd. Petach-Tikva IsraelOffi cine Volta S.p.A. Bologna ItalyIntelligent Building Systems Sp. z o.o. Wroclaw PolandAHI Carrier Moscow RussiaVavtar Inženiring d.o.o. Ljubljana SloveniaHiensch Engineering AB Stockholm SwedenMWH Barcol-air AG Stäfa SwitzerlandBarcol-Air UK Ltd. Bath United Kingdom America MWH Barcol-Air USA Santa Clara USA

Middle-East

Almoayyed Air Conditioning Manama BahrainAir Master Equipments India (P) Ltd. Bangalore IndiaWestech Air Equipments Bombay IndiaSauter Race Technologies Pvt. Ltd. Chennai IndiaTakvin Resaneh Tehran IranACE Supplies & Trading Co. Amman JordanBader Al Mulla & Brothers Co.W.L.L. Safat KuwaitDan International LLC Muscat OmanInstrumentation & Management Systems Karachi PakistanShahjan Trading Establishment Doha QatarDanway LLC Dubai United Arab EmiratesBahri & Mazroei Technical Systems Co. (LLC) Dubai United Arab EmiratesIndependent Technical Solutions LLC Dubai United Arab EmiratesAl Taqa Equipment Est. Abu Dhabi United Arab Emirates

Far-East

Air Con Serve Pty. Ltd. Norwood AustraliaXebec Trading Services Dhaka BangladeshStarec Ltd. Hong Kong Hong KongPT Barcol-Air Jakarta IndonesiaAir Filter Manila PhilippinesBarcol Air Engineering Pte Ltd Singapore SingaporeSouthern Automation Systems (Pvt) Ltd. Colombo Sri LankaBarcol Industries Taipei Taiwan

Page 24: Company Profile

HC Barcol-Air is part of

HC Barcol-Air P.O. Box 283, 1440 AG Purmerend - The NetherlandsT +31 (0)299 689 300 | F +31 (0)299 436 [email protected] | www.barcol-air.nl