company details - radiant cooling systems pvt. ltd.radiantcoolingsystems.com/upload/company profile...

15
301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com Company Details Name of Company M/s Radiant Cooling Systems Pvt. Ltd. Reg. / Admin office Address 301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W) - 400 602 Type of Company Private Limited VAT No. 27920902221V dated: 05.05.2012 CST TIN No. 27920902221C dated: 05.05.2012 GST No 27AAFCR7110Q1ZY MSME No. 27-021-11-05009-PART II dated: 31.12.2013 Registration No. U29253MH20PTC221446 SSI Registration No. 270211105009 Telephone No. 022-25402931 Mobile No. 09167700348 Email [email protected] / [email protected] Managing Director Mr. Bhushan Dhapte Bankers HDFC Bank Kalwa – Thane. CC. No. 50200009072800 CRISIL Rating SE 3 B Channel Partner Kirloskar - Chiller Samsung DVM Products- VRF System Godrej & Boyce Mfg. Co. Ltd.-(MEP division) Manufacturers/Suppliers Air Handling Units, Air Washer Units, Force Draft Ventilation Modular Clean room Systems, Clean Room Panels Clean room Door, Windows, View Glass, False Ceiling (i.e. Walkable & Non-Walkable) Clean room accessories i.e. pass Box, OT Module etc.

Upload: tranthuy

Post on 16-Apr-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

Company Details

Name of Company M/s Radiant Cooling Systems Pvt. Ltd. Reg. / Admin office Address 301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers,

Ram Maruti Road, Thane (W) - 400 602 Type of Company Private Limited VAT No. 27920902221V dated: 05.05.2012 CST TIN No. 27920902221C dated: 05.05.2012 GST No 27AAFCR7110Q1ZY MSME No. 27-021-11-05009-PART II dated: 31.12.2013 Registration No. U29253MH20PTC221446 SSI Registration No. 270211105009 Telephone No. 022-25402931 Mobile No. 09167700348 Email [email protected] / [email protected] Managing Director Mr. Bhushan Dhapte Bankers HDFC Bank

Kalwa – Thane. CC. No. 50200009072800

CRISIL Rating SE 3 B Channel Partner Kirloskar - Chiller Samsung DVM Products- VRF System Godrej & Boyce Mfg. Co. Ltd.-(MEP division) Manufacturers/Suppliers Air Handling Units, Air Washer Units, Force Draft Ventilation

Modular Clean room Systems, Clean Room Panels Clean room Door, Windows, View Glass, False Ceiling (i.e. Walkable & Non-Walkable) Clean room accessories i.e. pass Box, OT Module etc.

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

RADIANT COOLING SYSTEMS PVT. LTD.

DIRECTOR DIRECTOR(SALES & TECHNICAL) (PROJECTS & COMMERCIAL)

HR/ADMIN OFFICER

PEONS PEONS

CLERK

SALES MANAGER

SALES CO-ORDINATOR

SALES EXECUTIVE(EQUIPMENTS)

SALES ENGINEER(PROJECTS)

SALES ENGINEER(PROJECTS)

ACCOUNTS HEAD

ACCOUNT CLERK ACCOUNT CLERK

DESIGNING & ENGINEERING HEAD

DRAUGHTS MAN DRAUGHTS MAN DESIGN ENGINEER

PROJECT HEAD

PROJECT CO-ORDINATOR

PROJECT ENGG.- 1

SEVICE MANAGER

TECHNICIAN - 1+

HELPERPROCUREMENT HEAD

PURCHASE OFFICER / ASSISTANT OFFICER

FACTORY HEAD

PRODUCTION ENGINEER STORE KEEPER

PRODUCTION STAFF- 1

2 3 4 5 6

2 3 4 5 6

2 3 4 5 6 7 8

(1+1) (1+1) (1+1) (1+1) (1+1)

ORGANISATION CHART

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

Our Mission & Vision: Mission: Our belief is in Combining Cost Effective Solutions with the best Technology available with serious quality and safety Consideration. Vision: To expand our locations both domestic and overseas by being the company that best understands and has solutions to the HVAC and Clean Room requirements of our customers. Our Specialization:

Budgetary Estimations for Clean Room and HVAC turnkey projects HVAC and Clean Room Consultancy and Technical Services & Support Preparation of DQ, IQ, OQ and PQ documentation and facility Validation P & I Drawings for Chiller plant, AHU’s, Cooling Towers, Piping and Ducting with

necessary Electrical wiring diagrams. P & I Diagrams for Clean room equipments like LAF’s, Pass Boxes, Bio safety hoods,

etc.,. Cooling Load Estimations Heating Load Estimations Ventilation Load Estimations Chiller Units, Cooling Towers, Pumps, Valves, VFDs, etc. selection Selection & Supply of Air Handling Unit, Ventilation (FDV) Unit & Air Washer Unit. Selection of Heat Recovery Units, Dehumidifier Units, etc., Samsung DVM System Design, Supply, Installation, Testing, Commissioning &

maintaining. Uniflair Precision Air-Conditioning System Design, Supply, Installation, Testing,

Commissioning & Maintenance Continues improvement in efficiency with effective engineering is our prime motto to give our customers uttermost satisfaction.

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

Few of Our Projects: Since 7 years, we have been providing technical support to the industry in the field of Clean Room and HVAC projects for various companies as listed below, class of cleanliness 100-1,00,000 (Grade A, B, C, D) from Design, Project Execution and Validation. The details are:

BANKS :

ICICI, Chandivali, Mumbai York make water cooled screw chiller 250TR-4Nos Application: Comfort facility Status: Completed Project Cost: 456 Lacs

M/s SBI Bank–Aurangabad

Samsung DVM System(VRF) with Cassette & HiWall for comfort applications. Application: For office Comfort air conditioning with SAMSUNG DVM system. Temperature: 24 +/- 2 Deg C Relative Humidity: 55+/- 5% Equipment Details: Samsung DVM ODU of 54 HP Capacity system with, Cassette & HiWall units as IDU’s Status: Completed Project Cost: 33 Lacs COMMERCIAL:

M/s NITCO LTD.–Kanjurmarg & Thane

Samsung DVM System(VRF) with Cassette & HiWall for comfort applications. Application: For office Comfort air conditioning for total 12000 Sqft area with SAMSUNG DVM system. Temperature: 24 +/- 2 Deg C Relative Humidity: 55+/- 5% Equipment Details: Samsung DVM ODU with, Cassette & HiWall units as IDU’s Status: In progress Project Cost: 52 Lacs

M/s. Huntsman, Chandivali, Mumbai

York make water cooled screw chiller 180TR-3Nos Samsung make VRF of 482HP Application: Comfort & Lab facility Status: Completed Project Cost: 686 Lacs

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

M/s. GODREJ – PROJECT ITC COMMERCIAL GUNTUR Fire fighting PHE Status: In progress Project Cost: 60 Lacs INDUSTRIAL

M/s Siemens Ltd., Walunj, Aurangabad Supply, Installation, Commissioning & validation of HVAc system for production facility. Area: 1250 Sqm Temperature: 25Deg C Relative Humidity: 50+/- 5% Equipment Details: AHU, Condenser Unit, Electrical Panel, Cabling, Ducting, Duct Insulation, Under deck Insulation, Piping. Status: Completed Project Cost: 45 Lacs

M/s. Siemens Ltd., Kalwa Uniflair make Precision air conditioner to maintain very specific temperature & Humidity levels for Cardex unit. Temperature:22 +/- 2 Deg C Relative Humidity: 50+/- 5% Equipment Details: Uniflair make Pac Units, Piping, Ducting & duct Insulation Status: Completed Project Cost: 20 Lacs

M/s. Siemens Ltd., Kalwa Ventilation system for Oven area with tube axial fans. Equipment Details: Tube Axial fans, Ducting, Electrical Panel & cabling work. Status: In Progress Project Cost: 46.5 Lacs

M/s KOHLER LTD., Jaggadia, Dist.: Bharuch, Gujarat Total Turnkey solution including MS structure, Modular Clean room & HVAC system. Total Approximate area 275 Sq.M. Temperature: 25Deg C Relative Humidity: 50+/- 5% Equipment Details: Modular Panels, Samsung DVM system, Ducting, Insulation Project Cost: 94 Lacs.

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

M/s. Sandoz Pvt. Ltd., Kalwa AHU to be connected with chiller unit for UPS room to maintainvery specific temperature & Humidity levels. Temperature:22 +/- 2 Deg C Relative Humidity: 50+/- 5% Equipment Details: AHU, Chilled water piping,Ducting & duct Insulation. Status: In Progress Project Cost: 89 Lacs

GOVERNMENT

M/s DRDE, Nagpur

HVAC system for very critical Lab application. Need to maintain pressure of -15 Pascal in room & -5 Pascal in corridor. Total Approximate area 1100 Sq.M. Temperature: 24Deg C Equipment Details: AHU’s, Condenser Units, VAV Boxes less than 1 second response time. Status: Completed Project Cost: 85 Lacs

MGIMS- Hospital, Wardha

Air cooled chiller 60TR-2Nos Application: Operation Theatre Air conditioning Systems at Wardha Hospital. Status: On Going Project Cost: 75 Lacs

LABS/ HOSPITALS/PHARMACEUTICALS(CLEAN ROOM )

M/s OKASA Pharma Limited, MIDC Satara, Maharashtra (CIPLA GROUP)

Design, Supply, Installation, Commissioning and Validation of HVAC system for QC lab. Total Approximate area 250 Sq.M. Class of Cleanliness: 1000, 10000 & 100000. Temperature: 25Deg C Relative Humidity: 50+/- 5% Pressure Gradient: -40 to +40 Pascal’s with respect to ambient Equipment Details: Air Handling Units, Condensing Units, chilled water piping, Duct work and MCC panel board etc Status: Completed

M/s SCHOTT KAISHA- Jambusar- Baroda , Gujrat

Samsung DVM System(VRF) with AHU for Class 1 lac applications & other Areas. Application: For Cleanroom Application, Humidification & Ventilation System for Production Area And office Comfort air conditioning area with SAMSUNG DVM system. Temperature: 24 +/- 2 Deg C

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

Relative Humidity: 55+/- 5% Equipment Details: Samsung DVM ODU of 400 HP Capacity system with AHU, Cassette & HiWall units as IDU’s Status: Completed Project Cost: 475 Lacs

M/s ARCHPHARMA LABS LTD.–Andheri, Mumbai Samsung DVM System(VRF) with Cassette & HiWall for comfort applications. Application: For office Comfort air conditioning area with SAMSUNG DVM system. Temperature: 24 +/- 2 Deg C Relative Humidity: 55+/- 5% Equipment Details: Samsung DVM ODU of 200 HP Capacity system with, Cassette & HiWall units as IDU’s Status: Completed Project Cost: 86 Lacs

M/s Themis Medicare Ltd, Vapi-Gujarat Installation of Modular Clean Room and HVAC for API facility. Class of Cleanliness: 100K Temperature: 25Deg C Relative Humidity: 50+/- 5% Equipment Details: Low side work-ducting, Insulation, fabrication & modular wall panels, Ceiling etc. Status: Completed Project Cost: 125 Lacs

M/s FLAMINGO PHARMACEUTICALS LTD., Navi Mumbai. Design, Supply, Installation, Commissioning of HVAC system for clean room application. Total Approximate area 300Sqmt Temperature: 24Deg C Relative Humidity: 50+/- 5% Equipment Details: Air Handling Units, FDV’s, Chilled water piping, Ductwork Status: Completed Project Cost: 130 Lacs

M/s SUNSHINE GLOBAL Hospital- Surat / Baroda , Gujrat Samsung DVM S System(VRF) with AHU. Cassette & Hi walls Units for OT & other Areas. Application: For Operation Theatre, Cath Lab, ICCU, Conference, Rooms& other areas with SAMSUNG DVM S system. Temperature: 24 +/- 2 Deg C Relative Humidity: 55+/- 5% Equipment Details: Samsung DVM S ODU of 400 HP Capacity system with AHU, Cassette & Hi Wall units as IDU’s Status: Completed Project Cost: 475 Lacs

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

M/s Solitaire Hitech Products P. Ltd. – Bangalore ( 100% export EOU) Design, Installation, Commissioning of Modular Clean room & structural Work for Modular Paint Booth Application & HVAC system for various dept. Total Approximate area 400Sqmt Temperature: 25Deg C Relative Humidity: 50+/- 5% Equipment Details: Modular Panels, Air Handling Units, Condensing Units, etc Status: Completed Project Cost: 48 Lacs HOSPITALITY

M/s Hotel TAJ President – Vizag. Design, Installation, Commissioning of HVAC system for Engineering Workshop and Complete Hotel rooms. Total Approximate area 400 Sq.M. Temperature: 25Deg C Relative Humidity: 50+/- 5% Equipment Details: Modular Panels, Air Handling Units, Condensing Units, etc. Status: Completed Project Cost: 60 Lacs

M/s Hotel MIRADOR – Mumbai. Design, Installation, Commissioning of LOW SIDE- HVAC system for Complete Hotel rooms. Total Approximate area 400 Sq.M. Temperature: 25Deg C Relative Humidity: 50+/- 5% Equipment Details: Air Handling Units, etc. Status: Completed Project Cost: 30 Lacs ARCHITECTS

M/s. DELLA TECHNICA. Samsung DVM System(VRF) with Cassette & HiWall for comfort applications. Application: For their Prestigious clients-office Comfort air conditioning with SAMSUNG DVM system. Temperature: 24 +/- 2 Deg C Relative Humidity: 55+/- 5% Equipment Details: Samsung DVM ODU & IDU like Cassette & HiWall units as IDU’s Status: Completed Project Cost: 30 Lacs

M/s. Mayash Space Design Pvt. Ltd. Samsung DVM System(VRF) with Cassette & HiWall for comfort applications. Application: For office Comfort air conditioning with SAMSUNG DVM system.

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

Temperature: 24 +/- 2 Deg C Relative Humidity: 55+/- 5% Equipment Details: Samsung DVM ODU & IDU like Cassette & HiWall units as IDU’s Status:Completed Project Cost: 30 Lacs

Clean Room applications.

1. Ciron Drugs- Palghar 2. Omni Healthcare Pvt.Ltd., Thane & Pune, Maharashtra. 3. Titan Pharmaceuticals Pvt.Ltd., Mahad, Maharashtra. 4. Bliss Pharma Pvt.Ltd., Palghar, Maharashtra. 5. Jay Research Foundation Ltd. (united Phosphorus Group), Vapi, Gujarat. 6. Pratap Organic Pvt.Ltd, (API), Navi Mumbai, Maharashtra. 7. Mecloids Pharma Pvt.Ltd., Daman (U.T.). 8. Charak Pharma Pvt.Ltd., Silvassa (U.T.). 9. Matrix Ltd., Nasik, Maharashtra.

Other Customers to name the few :

1. Piramal Realty Ltd., Mumbai. 2. Hotel President (Taj Group), Vizag, Andhra Pradesh & Mumbai. 3. Diageo Pvt.Ltd., Mumbai. 4. Trans Union Pvt.Ltd., Mumbai. 5. NISM (National Institute of Security Management – SEBI Group), Navi Mumbai. 6. Blue Umbrella School (AD Plast group), Mumbai. 7. Religare Investments Pvt.Ltd., Mumbai. 8. Chola Mandalam Pvt.Ltd., Mumbai. 9. Orbit Corporation , Mumbai. 10. Prabhavati Patel Developers, Mumbai 11. BPCLChembur Mahul – Mumbai 12. Ramee Guestline Hotel.- Juhu Mumbai 13. The Retreat Hotel- Malad Mumbai 14. Arthi Pharma Tarapur – Maharashtra 15. Siemens Prabhadevi – Mumbai 16. Airtel Ltd. Malad – Mumbai 17. Gammon Worli – Mumbai 18. Raghuleela Mall Malad / Vashi 19. Zim Pharma Nagpur 20. ESI Hospital Parel – Mumbai 21. Cipla Pharma-Pune 22. L & T Technology Services Ltd. DLF IT Park – Chennai 23. West inn Pune 24. Phonix Mall Viman Nagar – Pune 25. Hindustan Lever Andheri (E) – Mumbai 26. Hotal Taj Kamath Goa – Panjim

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

27. Nasik Airport Nasik – Maharashtra 28. Metro Railway – Central Chennai 29. Civil Hospital Ahmadabad – Gujrat 30. Maker Maxity BKC – Mumbai 31. Oberoi Trident BKC – Mumbai 32. AMR Adventure Mall Gr. Noida (Delhi-NCR) 33. Asian Paints Ahmadabad – Gujrat 34. Reliance Mall Rajkot – Gujrat 35. Vidhan Bhavan Admin Building Raipur – Chhattisgarh 36. Appolo Hospital Lavasa – Maharashtra 37. LDC-Relainace Industries Ltd.Navi Mumbai 38. Sanghvi Gems Hazira – Surat 39. Hotel Fortune Indor – M.P. 40. Ever Shine Mall Malad – Mumbai 41. Phonix Mall Viman Nagar – Pune 42. Sri Krishna Dimond Surat – Gujrat 43. Parasi Diomond Surat – Gujrat 44. Shearton Lanka Residency Colombo-Srilanka 45. Hotal Dukes Khandala 46. Hotal Taj Gateway Kolhapur 47. Hotal Taj Gateway Visakhapatnam 48. Radisson Hotel Gandhidham – Gujrat 49. Sumilon Industries Surat – Gujrat 50. Breach Candy Hospital Mumbai 51. Sumilon Industries Gandhidham – Gujrat 52. Ispat Ltd.Alibagh – Maharashtra 53. Godrej & Boyce Mfg.Co.Ltd. 54. ITC– Guntur (Andhra Pradesh)

And many more……………………

With the above information we hereby humbly request you to register our firm in your approved list of vendors as SITC contractors for your HVAC & Clean Room future requirements. Thanking you & assuring you of our best services at all time. For, Radiant Cooling Systems Pvt.Ltd.

Mr. Bhushan Dhapte Managing Director 09324229514

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

SITE PICS – a. AHU with DX System

b. AHU with CHW system

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

c. Ceiling Suspended AHU with DX System

d. AHU with VRF (SAMSUNG) System

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

e. AHU with VRF (SAMSUNG) System-with EEV

MODULAR CLEANROOM SYSTEM A. GIPC/GIPC Wall panel with walkable ceiling, Doors & Epoxy flooring.

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com

B. IPC/GIPC Doors & Coving

301, Ishaan Co-op.Hsg.Soc.Ltd., Opp.P.N.Gadgil Jewellers, Ram Maruti Road, Thane (W)-400602 Contact No.: 022-25402931 www.radiantcoolingsystems.com