commercial air conditioners 2018/2019 · air cooled chillers & ac fan coil units commercial air...
TRANSCRIPT
1803-2C1805
Air Cooled Chillers & AC Fan Coil Units
Commercial Air Conditioners 2018/2019
Commercial Air Conditioner Division
Midea Group
Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China
Postal code: 528311
Tel: +86-757-26338346 Fax: +86-757-22390205
cac.midea.com global.midea.com
Note: Product speci�cations change from time to time as product improvements and developments are released and may vary from those in this document.
We have three production bases: Shunde, Chongqing and Hefei.
MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU.
MCAC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled Screw/Scroll
Chillers.
MCAC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters.
Midea CACMidea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating,
ventilation and air conditioning solutions. Midea CAC has continued with the tradition of innovation upon which it was
founded, and emerged as a global leader in the HVAC industry. A strong drive for advancement has created a
groundbreaking R&D department that has placed Midea CAC at the forefront of a competitive �eld. Through these
independent e�orts and joint cooperation with other global enterprises, Midea has supplied thousands of innovative
solutions to customers worldwide.
Midea Company Introduction
Midea CAC Introduction
2017 Developed the large capacity air cooled scroll chiller.
2016 Acquire an 80% stake in Clivet.
2015 Launched the inverter direct-drive centrifugal chiller and magnetic chiller.
An international strategic Platform has brought Midea Group, Carrier Corporation and Chongqing General
Industry Group together in the chiller business.
2013 Launched the super high e�ciency centrifugal chiller with dual-stage compressor and full falling �lm evaporator.
2008 Developed the Smart Star new-generation Semi-hermetic centrifugal chiller.
2007 Won the �rst Midea centrifugal chiller project overseas.
2006 Launched the �rst VFD (Variable Frequency Drive) centrifugal chiller.
2004 Acquired MGRE entered the chiller industry.
2001 The R134a (LC) series centrifugal chiller was named as a key national product.
1999 Entered the CAC �eld.
03 04
Intr
oduc
tion
Intr
oduc
tion
Introduction
Aqua Tempo Power Series
Aqua Tempo Super Series
Fan Coil Units
09
21
35
Midea air-cooled scroll chiller adopts air as the cooling/heating source and water as the cooling/heating medium
to cooling/heating the indoor ambient temperatures through the indoor terminals (AHUs/FCUs). They are
environment friendly products for the R410A refrigerant adopted, which does no harm to ozone layer. The chiller
system always works at the most high efficiency stage thanks to the advanced technology. Also, the air cooled
chiller system has a lower initial investment cost than water cooled system. It does not require cooling tower,
condenser water pump and associated condenser water chemical treatment system.
Midea air-cooled scroll chillers are divided to Tempo Power series and Tempo Super series according to their
structure and capacity. Single unit’s capacity range is from 30kW to 250kW. Modular design concept makes the
application from single unit to multiple units. Maximum combination air-cooled scroll system’s cooling capacity
ups to 2080kW.
Midea fan coil units are divided to ceiling exposed type, ceiling concealed type, wall-mounted type and
floor-standing type according to their structure design and installation method. The air volume ranges from
150CFM to 2200CFM (255m3/h~3740m3/h). It is a highly versatile product suitable for hospitals, office buildings,
hotels, airports and various other applications.
Contents
Reference Projects
05 06
Refe
renc
e Pr
ojec
ts
Refe
renc
e Pr
ojec
ts
Sports
Hotels & Resorts
Complex
Transportation
2015 Youth Olympic Games-Dinamp Arena
Country:
City:
Outdoor Units:
Indoor Units
Total Capacity:
Georgia
Tbilisi
Air-cooled modular chiller
FCU & AHU
780kW
2015 Youth Olympic Games-Volleyball Arena
Country:
City:
Outdoor Units:
Indoor Units
Total Capacity:
Georgia
Tbilisi
Air-cooled modular chiller
FCU & AHU
400kW
Jakarta International Airport
Country:
City:
Outdoor Units:
Indoor Units
Total Capacity:
Indonesia
Jakarta
Air-cooled screw chiller
FCU & AHU
1,400kW
Sheraton Bandara Resort Hotel(Five Star)
Country:
City:
Outdoor Units:
Total Capacity:
Completion Year:
Indonesia
Jakarta
Air-cooled screw chiller
1,050RT
2011
Grand Comfort Material Market
Country:
Outdoor Units:
Indoor Units
Total Capacity:
Completion Year:
Kyrgyzstan
Air-cooled modular chiller
FCU & AHU
5,780kW
2015
Grand Comfort is the largest material market in middle Asia, the total area is 55,000 square meters. Midea CAC provided 21 air-cooled
power and super modular chillers for the project.
The total capacity is up to 5,780kW.
Industry
Education
07 08
Refe
renc
e Pr
ojec
ts
Refe
renc
e Pr
ojec
ts
Harvey Nichols Edinburgh
Country:
City:
Outdoor Units:
Indoor Units
Total Capacity:
UK
Edinburgh
Air-cooled modular chiller
FCU
255HP
City Mall
Country:
City:
Outdoor Units:
Indoor Units
Total Capacity:
Tanzania
Dar es Salaam
Air-cooled modular chiller
FCU & AHU
1,560kW
Zetes Power Station
Country:
City:
Outdoor Units:
Indoor Units
Total Capacity:
Turkey
Zonguldak
Precision A/C, VRF, Air-cooled
modular chiller
Duct & Cassette, AHU
500HP
Komar University
Country:
City:
Outdoor Units:
Indoor Units
Total Capacity:
Iraq
Sulaymaniyah
Air-cooled serew & scroll chiller
FCU & AHU
2,350kW
09 10
Aqu
a Te
mpo
Pow
er
Aqu
a Te
mpo
Pow
er
Midea Aqua Tempo Power chillers use V shape heat exchanger and single unit’ s capacity from 30kW to 250kW.They are divided
to PS and PS-LA series according to their operation ambient temperature range and inner components. PS-LA series are
products with low ambient temperature cooling function.
Product Lineup
Aqua Tempo PowerAir Cooled Scroll Chiller
Series
Appearance
Capacity (kW) 30 65 130 200250
50Hz PS (F/D) / / / / /
50Hz PS-LA(F/D) / / / / /
60Hz PS (F/D) / / / / /
PS: Standard Power Series PS-LA: Power Series with low ambient temperature cooling functionF: Product adopted fixed speed scroll compressorD: Product adopted digital scroll compressor
11 12
Aqu
a Te
mpo
Pow
er
Aqu
a Te
mpo
Pow
er
Aqua Tempo Power Chillers with cooling capacity ranging from 30kW to 250kW, combination model’s maximum capacity ups to
2000kW.
Freely combine with fan coil units and air handling units. Project owners may choose the best types according to their design
taste (for interior) or functional needs.
Wide ambient temperature operating range
For the Aqua Tempo Power chillers with low ambient temperature cooling function, the running ambient temperature down
to -10°C both in cooling and heating.
FeaturesWide application range
250kW 250kW 2000kW
Max 8 modules
Cassette type
Air handling units
Celling & Floor
Floor standing
Wall mounted
Duct type
Advanced technologyDigital scroll technology
PWM valve
DischargeFixed Scroll
Suction
Orbiting Scroll
The digital scroll compressor utilizes axial compliant sealing technology to precisely adjust the axial motion range of the stator
scroll pan. And there is an additional connecting by-pass between the suction inlet and the pressure bore at the floating sealing
point of axial stator.
Operation Principle of Digital Scroll Compressor
When the PWM solenoid valve is open, the pressure in the pressure bore is
released. The pressure in the compression bore is higher than that top of
the stator, then the stator axis of the compressor will move upward a little.
So high pressure bore and low pressure inlet is connected and the unload-
ing is achieved.
When the PWM solenoid valve is closed, two stators engage to achieve an
airtight state and loading functionality.
The compressor can adjust the ratio of ON to OFF freely to control the refrig-
erant output of the compressor.
Provides 40 million times the average service life of PWM
solenoid valves, making sure the long life of compressor.
Guarantees high efficiency by applying axial-compliant
sealing technology.
Provides 10% to 100% stepless capacity output to
precisely control room temperature.
Less electromagnetic interference, no EMC problem.
Compressor motor
Suction
Discharge
High reliability in high ambient temperatures is guaranteed by the low pressure design of the compressor motor.
Effectively cools the compressor motor by suction gas.
Creates stronger resistance to the compressor liquid hammer.
Provides strong reliability in high ambient temperatures.
Inverter EMC Regulation Digital Scroll System
5th
7th
11th
13th
17th
19th 0 1 2 3 4 5
Ampere
EMW
CO
OLI
NG
HEA
TIN
G
-10˚C
46˚C
-10˚C
24˚C
46˚C 27˚C 27˚C-10˚C
Wide outlet water temperature range
For the Aqua Tempo Power chillers with low water outlet temperature function, the lowest outlet temperature in cooling
mode is 0°C.17°C0°C
COOLING MODE
50°C22°C
HEATING MODE
13 14
Aqu
a Te
mpo
Pow
er
Aqu
a Te
mpo
Pow
er
The new designed window fins enlarge the heat-exchanging area, decrease the air resistance, save more power and enhance heat
exchange performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents, assures
a longer coil service life.
Touch key wire controller as standard accessory to control the chillers.
Remote control functions for convenient operation.
There are ON/OFF, Heat/Cool and Alarm terminals ports on PCB, connect switches from these terminal ports and remote
control functions can be easily realized.
In a combination system, if one module failed, other modules can be back-up instead of the failed one for continuing operation.
30kW and 65kW products are compliance with ErP directive, including both PS series and PS-LA series. The seasonal space heating
energy efficiency classes for 30kW models are A rated and 65kW models are A+ rated.
Compliance with ErP directive
Easy controlHigh performance heat exchanger
Back-up functions
New design
Original design
High efficiency inner-threaded pipe, enhance heat transfer.
Reduce air resistance
Hydrophilic fins + inner-threaded pipes
Master SlaveMaster Slave
Note: When use the remote control function, the wired controller will be invalid for ON/OFF and mode selection.
15 16
Aqu
a Te
mpo
Pow
er
Aqu
a Te
mpo
Pow
er
50Hz PS & PS-LA series (Fixed type)Speci�cations
1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.3. 1m away in open field.4. The date is for PS-LA series.5.The data is for low water outlet temperature function
MGC-F30W/RN1(B)MGCL-F30W/RN1
MGBL-F65W/RN1
V/Ph/Hz 380-415/3/50 380-415/3/50
Capacity kW 30 65
Input kW 10.0 20.4
3.00 3.18
Capacity kW 32 69
Input kW 9.8 21.5
3.27 3.21
A 21.1 54.5
Fixed Scroll Fixed Scroll
Quantity Pieces 2 2
Fin-coil Fin-coil
AC Motor AC Motor
Quantity of fan motor Pieces 1 2
Air flow m3/h 12,000 24,000
Double-pipe Shell-tube
Water pressure drop kPa 60 15
Volume L 10 42
Water flow volume m3/h 5.2 11.2
Type R410A R410A
Charged volume kg 7.0 14.0
EXV EXV
dB(A) 65 67
mm 1,514×1,865×841 2,000×1,880×900
mm 1,590×2,065×995 2,106×2,090×998
kg 375/400 580/650
Pipe connections Water inlet/outlet mm DN40 DN100
Wired controller Wired controller
Cooling °C 10~46
Heating °C -10~24
Cooling °C -10~46
Heating °C -10~24
Cooling °C 5~17
Heating °C 40~50
Cooling °C 0~17
Heating °C 22~50
10~46
-10~24
-10~46
-10~24
5~17
40~50
0~17
22~50
Model
Cooling1
Heating2
Power supply
Max. running current
EER
COP
Net/ Gross weight
Type
Water s ide heat exchanger
Type
CompressorType
Fan motor type
Refrigerant
Sound pressure level3
Air s ide heat exchanger
Throttle type
Unit net dimension(D×H×W)
Packing dimension(D×H×W)
Ambient temperature
range
Ambient temperature
range4
Water outlet temperature
range
Water outlet temperature
range5
Controller
50Hz PS & PS-LA series (Fixed type)
1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.3. 1m away in open field.4. The date is for PS-LA series.5.The data is for low water outlet temperature function
MGB-F130W/RN1(B)MGBL-F130W/RN1
MGB-F200W/RN1(B)MGBL-F200W/RN1
MGBL-F250W/RN1
V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50
Capacity kW 130 185 250
Input kW 40.8 63.0 78.3
3.18 2.93 3.19
Capacity kW 138 200 270
Input kW 43.0 61.0 80.0
3.21 3.27 3.38
A 109 150 200
Fixed Scroll Fixed Scroll Fixed Scroll
Quantity Pieces 4 6 8
Fin-coil Fin-coil Fin-coil
AC Motor AC Motor AC Motor
Quantity of fan motor Pieces 4 6 8
Air flow m3/h 48,000 72,000 96,000
Shell-tube Shell-tube Shell-tube
Water pressure drop kPa 25 30 40
Volume L 64 90 131
Water flow volume m3/h 22.4 31.8 43
Type R410A R410A R410A
Charged volume kg 28.0 42.0 60.0
EXV EXV EXV+Capillary
dB(A) 70 74 74
mm 2,000×2,090×1,685 2,850×2,110×2,000 3800×2130×2000
mm 2,090×2,240×1,755 2,980×2,260×2,135 3900×2200×2100
kg 1,150/1,270 1730/2,000 2,450/2,600
Pipe connections Water inlet/outlet mm DN65 DN80 DN100
Wired controller Wired controller Wired controller
Cooling °C
Heating °C
Cooling °C
Heating °C
Cooling °C
Heating °C
Cooling °C
Heating °C
10~46
-10~24
-10~46
-10~24
5~17
40~50
0~17
22~50
10~46
-10~24
-10~46
-10~24
5~17
40~50
0~17
22~50
10~46
-10~24
-10~46
-10~24
5~17
40~50
0~17
22~50
Model
Cooling1
Heating2
Power supply
Max. running current
EER
COP
Net/ Gross weight
Type
Water s ide heat exchanger
Type
CompressorType
Fan motor type
Refrigerant
Sound pressure level3
Air s ide heat exchanger
Throttle type
Unit net dimension(D×H×W)
Packing dimension(D×H×W)
Ambient temperature
range
Ambient temperature
range4
Water outlet temperature
range
Water outlet temperature
range5
Controller
Aqu
a Te
mpo
Pow
er
Aqu
a Te
mpo
Pow
er
17 18
60Hz PS series
1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.3. 1m away in open field.
MGB-F65W/PN1
V/Ph/Hz 380/3/60
Capacity kW 65
Input kW 21.3
3.20
Capacity kW 70
Input kW 21.9
3.20
A 51.5
Fixed Scroll
Quantity Pieces 2
Finned tube
AC Motor
Quantity of fan motor Pieces 2
Air flow CFM(m3/h) 14,126(24,000)
Shell-tube
Water pressure drop kPa 15
Volume L 42
Water flow volume CFM(m3/h) 6.6(11.2)
Type R410A
Charged volume lbs(kg) 30.8(14.0)
EXV
dB(A) 67
inch 78-47/64×74-1/64×35-7/16
mm 2,000×1,880×900
inch 82-9/32×80-29/32×38-25/32
mm 2,090×2,055×985
lbs 1,301/1,389
kg 590/630
Pipe connections Water inlet/outlet mm DN100
Wired controller
Cooling °F(°C) 50~118(10~48)
Heating °F(°C) 14~75(-10~24)
Cooling °F(°C) 41~63(5~17)
Heating °F(°C) 113~122(45~50)
Model
Heating2
Power supply
Max. running current
Cooling1
EER
Throttle type
COP
Type
Water s ide heat exchanger
Type
Compressor
Type
Fan motor type
Refrigerant
Air s ide heat exchanger
Controller
Sound pressure level3
Ambient temperature range
Water outlet temperature range
Net/Gross weight
Unit net dimension(D×H×W)
Packing dimension(D×H×W)
1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.3. 1m away in open field.4. The date is for PS-LA series.5.The data is for low water outlet temperature function.
50Hz PS & PS-LA series (Digital type)MGC-D30W/RN1(B)MGCL-D30W/RN1
MGB-D65W/RN1(B)MGBL-D65W/RN1
V/Ph/Hz 380-415/3/50 380-415/3/50
Capacity kW 30 65
Input kW 10.0 20.4
3.00 3.18
Capacity kW 32 69
Input kW 9.8 21.5
3.27 3.21
A 21.1 54.5
Digital Scroll+Fixed Scroll Digital Scroll+Fixed Scroll
Quantity Pieces 2 3
Finned tube Finned tube
AC Motor AC Motor
Quantity of fan motor Pieces 1 2
Air flow m3/h 12,000 24,000
Double-pipe Shell-tube
Water pressure drop kPa 60 15
Volume L 10 42
Water flow volume m3/h 5.2 11.2
Type R410A R410A
Charged volume kg 7.0 14.0
EXV EXV
dB(A) 65 67
mm 1,514×1,865×841 2,000×1,880×900
mm 1,590×2,065×995 2,106×2,090×998
kg 375/400 610/680
Pipe connections Water inlet/outlet mm DN40 DN100
Wired controller Wired controller
Cooling °C
Heating °C
Cooling °C
Heating °C
Cooling °C
Heating °C
Cooling °C
Heating °C
Model
Power supply
Max. running current
Throttle type
Type
Water s ide heat exchanger
Type
Compressor
Type
Fan motor type
Refrigerant
Cooling1
Heating2
COP
EER
Air s ide heat exchanger
Controller
Water outlet temperaturerange
Water outlet temperaturerange5
Net/Gross weight
Unit net dimension(D×H×W)
Packing dimension(D×H×W)
Ambient temperature range
Ambient temperature range4
Sound pressure level3
10~46
-10~24
-10~46
-10~24
5~17
40~50
0~17
22~50
10~46
-10~24
-10~46
-10~24
5~17
40~50
0~17
22~50
Aqu
a Te
mpo
Pow
er
Aqu
a Te
mpo
Pow
er
19 20
200kW module
B
AF
C
E
D
250kW module
B
AF
C
E
D
65kW module
CFD
EA
B
Dimensions (Unit:mm)30kW module
D
E
F
C
B
A
Model A B C D E F
MGB-D65W/RN1(B)MGBL-F(D)65W/RN1MGB-F65W/PN1
2000 900 1880 350 506 1420
MGB-F130W/RN1(B)MGBL-F130W/RN1
2000 1685 2080 350 506 1420
MGB-F200W/RN1(B)MGBL-F200W/RN1
2850 2000 2110 347 506 2156
MGBL-F250W/RN1 3800 2000 2130 1235 573 2156
130kW module
D F C
EA
B
21 22
Aqu
a Te
mpo
Sup
er
Aqu
a Te
mpo
Sup
er
Air Cooled Scroll Chiller
Midea Aqua Tempo Super chillers use H shape heat exchanger at air side and single unit’s capacity from 25kW to 130kW. Super
chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water side heat exchanger and inner components. SS
series use tube-in-tube or shell-tube heat exchanger and SP series use plate type heat exchanger at water side. SS-LA and SP-LA
series are products with low ambient temperature cooling function based on SS and SP series. SP-HMLA series are products
built-in with hydraulic module based on SP-LA products.
Product Lineup
Aqua Tempo Super
Series
Appearance
Capacity (kW) 25
SP-LA
SP-HMLA
SS-LA
SS
35 65 80 130
SP-LA: Super series with low ambient temperature cooling function based on SP seriesSP-HMLA: Super series built-in hydraulic module based on SP-LA seriesSS:Super series use tube-in-tube or shell-tube heat exchangerSS-LA: Super series with low ambient temperature cooling function based on SS series
/
/ / / /
/ /
/ /
/
/
23 24
Aqu
a Te
mpo
Sup
er
Aqu
a Te
mpo
Sup
er
Aqua Tempo Super chillers with cooling capacity ranging from 25kW to130kW, combination model’s maximum capacity ups
to 2080kW. The chillers use new structure design, H shape condenser, 360°air intake, increase the heat exchanging area, efficiently enhance
the heat exchange efficiency, and decrease the covering area.
H shape condenser uses inner grooved copper tube and hydrophilic aluminum foil, greatly improve the heat exchange efficiency.
Freely combine with fan oil units and air handling units. Home owners may choose the best types according to their functional
needs.
FeaturesWide application range
Advanced technology
H shape high performance heat exchanger
Max 16 modules
130kW 130kW 2080kW
Cassette type
Wall mounted
Duct type
Air handling units
Celling & Floor
Floor standing
Wide ambient temperature operating range
CO
OLI
NG
HEA
TIN
G
-10˚C
46˚C
-15˚C
24˚C
46˚C 27˚C 27˚C-15˚C
Wide outlet water temperature range
Newly designed air profileBig air flow lower noise
360° Condenser coilHigh efficiency
Removable panelEasy to maintain
Transportation holeEasy to install
Multi folder frameNice and strong
4
3
2
1
5
Hydrophilic aluminum foilInner grooved copper tube
17°C0°C
COOLING MODE
50°C25°C
HEATING MODE
25 26
Aqu
a Te
mpo
Sup
er
Aqu
a Te
mpo
Sup
er
Patented liquid distribution components to maximize performance and minimize defrost impact.
500 steps EXV plus capillary for stable and accurate gas flow control.
Fast respond resulting in higher efficiency and improved reliability.In one combination module, all slave units operate as alternative in cycle duty to keep equal running time, realize higher stability,
better reliability and longer lifespan.
For example, five modules combination, no.1 is master unit, others are slave units.
High reliabilityEXV for more precisely flow control
Alternative cycle duty operation
Back-up functions
Reliable protections
High efficiency plate heat exchanger (For SP series)
Tube-in-tube & shell-tube heat exchanger (For SS series)
0%
25%
50%
75%
100%
Refrigerant inlet
Refrigerant outlet
Water inlet
Water outletPlate heat exchanger uses metal plates to transfer heat between
refrigerant and water. The fluids are exposed to a much larger surface
area because the fluids spread out over the plates, so both heat transfer
efficiency and heat exchanger speed are greatly improved.
Multi protections including voltage protection, current protection,
anti-freezing protection and water flow protection ensure system
safety running.
For shell-tube heat exchanger, the module adopts the new helical baffle design to avoid the rectangular place of water dead
zone, greatly improve the heat exchange efficiency.
Chilled water inletRefrigerant inlet
Chilled water outlet
Refrigerant outlet
Flat baffle plate
Helical baffle
Water dead zone
1 3 452
1 2 3 45
1 3 2 45
In a combination system, if one module failed, other modules can be back-up instead of the failed one for continuing operation.
Slave
Master Slave
Master
Multiple protections are adopted to ensure system stable running.
Power phases sequence protection
Frequently ON/OFF protection of compressor
System anti-freezing protection in winter
Evaporator low temperature protection in cooling
Over-current protection
of compresor
Air discharge temperature protection of compressor
Sensor malfunction protection
Water flow protectionSystem high temperature protection
High/low pressure protection of compressor
27 28
Aqu
a Te
mpo
Sup
er
Aqu
a Te
mpo
Sup
er
Flexible installation
Intelligent defrosting technology
Compact structure design
Model alternative defrosting technology ensures little fluctuation on water temperature.
Manual defrosting program is available for service purpose.
Super power chiller uses compact structure design, light weight, easy for transportation and installation.
For SP series, built-in hydraulic module products are available. The modules are fully integrated and built-in expansion tank, plate
heat exchanger, water circulating pump, etc. It saves you much installation space and cost.
T min Time saving
Time
Hea
ting
capa
city
Midea Fast Defrosting Traditional defrosting
7 minutes less!
Built-in hydronic module
Inner grooved copper tubeCapacity & efficiency increase
Big air flow but low noise fanBig torque high efficiency fan motor
Control boxEasy to maintain
Scroll compressorHigh efficiencyLow noise
EXV500 steps
Helical baffle Efficiency increase 10%
Multi folder frameLow vibration. Durable and stable
7
1
6
5
4
3
2
Touch key wire controller as standard accessory to control the chillers.
There are ON/OFF, Heat/Cool and Alarm terminals ports on PCB, connect switches from these terminal ports and remote control
functions can be easily realized.
Easy control
Hydraulic Module
Remote control functions for convenient operation
Note: When use the remote control function, the wired controller will be invalid for ON/OFF and mode selection.
SP-LA series
29 30
Aqu
a Te
mpo
Sup
er
Aqu
a Te
mpo
Sup
er
Speci�cationsSP-HMLA series
1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.3. 1m away in open field.4.The data is for low water outlet temperature function.
1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB. 3. 1m away in open field.4.The data is for low water outlet temperature function.
MC-SP25-RN1L MC-SP35-RN1L MC-SP65-RN1L
V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50
Capacity kW 25 35 65
Input kW 8.0 11.5 20.4
3.13 3.04 3.19
Capacity kW 26 37 69
Input kW 8.0 11.3 21.5
3.27 3.27 3.21
A 20.7 28.8 54.5
Fixed Scroll Fixed Scroll Fixed Scroll
Quantity Pieces 1 1 1
Finned tube Finned tube Finned tube
AC Motor AC Motor AC Motor
Quantity of fan motor Pieces 1 1 2
Air flow m3/h
m3/h
13,500 13,500 27,000
Plate type Plate type Plate type
Water pressure drop kPa 77 63 55
Volume L 1.89 2.77 4.44
Water flow volume 4.3 6 11.2
R410A R410A R410A
Charged volume kg 3.1 5.4 10
EXV EXV EXV
dB(A) 65 65 67
mm 1,020×1,770×980 1,020×1,770×980 2,000×1,770×960
mm 1,070×1,900×1030 1,070×1,900×1030 2,090×1,890×1030
kg 276/286 304/314 470/490
Pipe connections Water inlet/outlet mm DN40 DN40 DN50
Wired controller Wired controller Wired controller
Cooling °C
Heating °C
Cooling °C
Heating °C
Cooling °C
Heating °C
Model
Power supply
Max. running current
Heating2
Cooling1
EER
COP
Throttle type
Type
Fan motor type
Water side heatexchanger
Type
Controller
Compressor
Sound pressure level3
Unit net dimension(D×H×W)
Packing dimension(D×H×W)
Net/Gross weight
Type
Refrigerant
Air side heat exchanger
Type
-10~46
-15~24
5~17
45~50
0~17
25~50
-10~46
-15~24
5~17
45~50
0~17
25~50
-10~46
-15~24
5~17
45~50
0~17
25~50
Water outlettemperature range
Water outlettemperature range4
Ambient temperaturerange
MC-SP35M-RN1L
V/Ph/Hz 380-415/3/50
Capacity kW 35
Input kW 12.7
2.76
Capacity kW 38
Input kW 12.5
3.04
A 32.1
Fixed Scroll
Quantity Pieces 1
Finned tube
AC Motor
Quantity of fan motor Pieces 1
Air flow m3/h 13,500
Plate type
Volume L 2.77
Water flow volume m3/h 6
R410A
Charged volume kg 5.4
EXV
dB(A) 65
mm 1,020×1,770×980
mm 1,070×1,900×1,030
kg 343/353
Pipe connections Water inlet/outlet mm DN40
Wired controller
Model
Power supply
Max. running current
Fan motor type
Air side heat exchanger
Type
Type
Throttle type
EER
Cooling1
Heating2
COP
Water side heat
exchanger
Type
Controller
Unit net dimension(D×H×W)
Packing dimension(D×H×W)
Sound pressure level3
Net/Gross weight
Compressor
Type
Refrigerant
Cooling °C
Heating °C
Cooling °C
Heating °C
Cooling °C
Heating °C
-10~46
-15~24
5~17
45~50
0~17
25~50
Water outlettemperature range
Water outlettemperature range4
Ambient temperaturerange
Aqu
a Te
mpo
Sup
er
Aqu
a Te
mpo
Sup
er
SS series & SS-LA series
31 32
1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.3. 1m away in open field.4. The date is for SS-LA series .5.The data is for low water outlet temperature function
MC-SS35/RN1L MC-SS65/RN1L MC-SS80/RN1L MC-SS130/RN1L
V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
Capacity kW 35 65 80 130
Input kW 11.5 20.4 25.8 42.3
3.04 3.19 3.10 3.07
Capacity kW 37 69 85 138
Input kW 11.3 21.5 26.5 43
3.27 3.21 3.21 3.21
A 27.0 54.5 65 109
Fixed Scroll Fixed Scroll Fixed Scroll Fixed Scroll
Quantity Pieces 1 1 2 2
Finned tube Finned tube Finned tube Finned tube
AC Motor AC Motor AC Motor AC Motor
Qualitity of fan motor Pieces 1 2 2 2
Air flow m3/h 13,500 27,000 27,000 50,000
Double-pipe Shell-tube Shell-tube Shell-tube
Water pressure drop kPa 55 30 30 40
Volume L 10 35 47.5 60
Water flow volume m3/h 6 11.2 13.8 22.4
R410A R410A R410A R410A
Charged volume kg 5.4 11.5 13 21
EXV EXV EXV EXV
dB(A) 65 67 67 68
mm 1,020×1,770×980 2,000×1,770×960 2,000×1,770×960 2,200×2,060×1,120
mm 1,070×1,900×1,030 2,090×1,890×1,030 2,090×1,890×1,030 2,250×2,200×1,180
kg 320/330 530/590 645/710 950/1,020
Pipe connections Water inlet/outlet mm DN40 DN65 DN65 DN65
Wired controller Wired controller Wired controller Wired controller
Cooling °C 10~46
Heating °C -15~24
Cooling °C -10~46
Heating °C -15~24
Cooling °C 5~17
Heating °C 45~50
Cooling °C 0~17
Heating °C 25~50
10~46
-15~24
-10~46
-15~24
5~17
45~50
0~17
25~50
10~46
-15~24
-10~46
-15~24
5~17
45~50
0~17
25~50
10~46
-15~24
-10~46
-15~24
5~17
45~50
0~17
25~50
Ambient temperature
range
Ambient temperature
range4
Model
Power supply
Max. running current
Type
Refrigerant
Fan motor typeAir side heat
exchanger
Type
Water outlet
temperature range
Water outlet
temperature range5
Cooling1
Heating2
EER
COP
Type
Throttle type
Unit net dimension(D×H×W)
Packing dimension(D×H×W)
Water side heat
exchanger
Type
Controller
Sound pressurer level3
Net/Gross weight
Compressor
Dimensions (Unit:mm)MC-SS35/RN1L MC-SS65/RN1L
and MC-SS80/RN1L
C
FD
E
F
C
E
D
MC-SS130/RN1(L)
A
B
A
B
B
AF
C
E
D
MC-SS130/RN1(L)
MC-SS35/RN1L
MC-SS65/RN1L
MC-SS80/RN1L
Model A B C D E F
1020 980 1770 237 250 400
2000 960 1770 336 506 1420
2200 1120 2060 390 347 1420
33 34
Aqu
a Te
mpo
Sup
er
Aqu
a Te
mpo
Sup
er
Wired controllerControl System
Model KJRM-120D/BMK-E(standard) KJR-120A/MBTE(optional)
Appearance
Main Functions Parameter setting and display. Real time clock control.Manual reset.Remote control icon display.Hysteresis temperature setting.Touch key operation
Parameter setting and display.Real time clock control.Manual reset.Remote control icon display.Hysteresis temperature setting. Weekly timing function.
Applied Range Aqua Tempo Power & Aqua Tempo Super Aqua Tempo Power & Aqua Tempo Super
Max. connection PCBs 16 16
Compatible Gateway Modbus & Lon Works Lon Works
Max. 16 (P Q E)
(P Q E)
Modbus
gateway
Modbus
gateway
Computer
(X Y E)
(X Y E)
Max. 16 units
Max. 16 units
LonWorks gateway controls the central A/C to facilitate the building management system (BMS). Main settings of LonWorks:
operation Mode, outlet water temperature, hysteresis temperature and clear alarm.
There are two connection methods for LonWorks:
Modbus gateway can be customized by adding X, Y, E ports on wired controller KJRM-120D/BMK-E. It can connect Max. 16 wired
controllers and each controller can control Max. 16 units.
LonWorks gateway
Air-cooled Scroll units: Max. 16 units
LONWORKSNET WORK
LSQ-LONWORKS
BMS SYSTEM
RS485(P Q E)
Air-cooled Scroll units:Max. 16 units
LSQ-LONWORKS
BMS SYSTEM
RS485(P Q E)
Connection 1 Connection 2
RS485(P Q E) LONWORKSNET WORK
C
E
D
F
B
F
D
E
C
A
A
B
A
B
MC-SP25-RN1L
MC-SP35(M)-RN1L
MC-SP65-RN1(L)
Model A B C D E F
1020 980 1770 303 181 481
2000 960 1770 396 188 466
MC-SP25-RN1Land MC-SP35(M)-RN1L
MC-SP65-RN1L
35 36
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Midea Fan Coil Units have ceiling exposed type, ceiling concealed type, wall-mounted type and floor-standing type. The air
volume ranges from 150CFM to 2200CFM. It is a highly versatile product suitable for hospitals, office buildings, hotels, airports and
various other applications.
Fan Coil UnitsM -K T3 E2200 G100
Type Code
Midea
Static PressureG12: 12Pa; G:30: 30Pa; G50: 50Pa;G70: 70Pa; G100: 100Pa;
Fuction Code
Nominal Air Volume (CFM)
Chilled Fan Coil Unit
Nomenclature
37 38
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Product Lineup
2-Pipe FCUs
Air volume (CFM)
1-way cassette
4-way cassette
Wall mounted
Ceiling & floor
Floor standing
150 200 250 300 400 450 500 600 750 800 850 900 950 1000 1200 1400 1500 1600 1800 2000 2200
Compact 4-way cassette
Duct
High static pressure Duct
4-Pipe FCUs
Air volume (CFM)
4-way cassette
Duct
200 300 400 500 600 750 800 850 950 1000 1200 1400 1500
Compact 4-way cassette
450100 900250 1600 1800 2000 2200
Note:The standard power supply for all fan coil units is 220V-240V/50Hz; 208-230V/60Hz can be customized for some series of fan coil units, for further information, please
contact with our salesmen.
39 40
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Cassette Series
300/400CFM
600CFM
Compact 4-way Cassette
4-way Cassette
1-way Cassette
Compact design, ultra slim body with a minimum thickness of
153mm, especially suitable for narrow ceiling, such as in lobbies
and small meeting rooms.
153mm UItra thin
Min. 153mm Thickness
One direction air flow guarantees quick cooling, flexible installa-
tion positioning.
One Direction Air Flow
High-lift PumpStandard built-in drain pump with 750mm pump head.
750mm
Single direction airflow, flexibly installed in various corners
One direction air flow
Speci�cations
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.
Power supply
Air flow (H/M/L)
Cooling
Heating
Power input (H/M/L)
Auxiliary electric heater (AEH)
Sound pressure level (H/M/L)
Fan motor
Fan
Coil
Panel
Body
Pipe
connections
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight (non-AEH/with-AEH)
Gross weight (non-AEH/with-AEH)
Water inlet/outlet pipe
Drain pipe
V/Ph/Hz
m3/h
CFM
kW
L/h
kPa
kW
kPa
W
W
dB(A)
MPa
mm
mm
mm
kg
kg
mm
mm
kg
kg
inch
mm
510/450/400
300/270/240
3.04/2.79/2.56
520
14
5.13/4.69/4.04
9
32/22/15
750
36/34/32
1
2
1180x25x465
1232x107x517
3.5
5.2
1054x153x425
1155x245x490
12.8/13.1
16.6/17.1
630/560/500
370/330/300
3.79/3.58/3.38
650
20
6.41/5.86/5.11
16
40/30/25
750
37/35/34
1
2
1180x25x465
1232x107x517
3.5
5.2
1054x153x425
1155x245x490
12.8/13.1
16.6/17.1
1000/880/800
590/520/470
5.709/4.85/4.36
982
20.2
9.6/8.36/7.48
18.1
125/88/65
/
42/39/37
4
3
1420×10×755
1500×110×870
9
12
1200×198×655
1380×265×720
32.6
36.3
220-240/1/50
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
1.6
Φ7
RC1/2
ODΦ25
Model
ModelNon-AEH MKC-300R-B MKC-400R-B MKC-600HRN4
With-AEH ///
1-way Cassette
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
41 42
4-way Cassette
Various SelectionsVersions for 2/4 pipe systems.
Versions for compact/normal size.
4-way air supply panel is standard for 4-way cassette.
360°air supply panel is standard for compact 4-way cassette.
Stylish Panel with Large Air�ow Outlet
4-way panel 360°panel
For Compact Four-way Cassette: Extremely compact casing suits any
room's decor and requires little space for installation on a low ceiling.
Due to compact body and light weight, all models can be installed without
a hoist.
Safe factory-installed electric heater is optional.
Extended drainage pan is optional.
Wireless controller is standard, and wired controller is optional.
Standard built-in drain pump with 750mm pump head for normal
size and 500mm for compact size.
575mm
261mm
575mm
Compact Design, Easy Installation
Various Accessories Selections
High-lift Drain Pump
Fresh air can enter through the cassette unit so you can enjoy even
fresher air in a room.
Fresh Air Intake
750mm
2-Pipe 4-Way Cassette
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.
Power supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Auxiliary electric heater (AEH)Sound pressure level (H/M/L)Fan motor
Fan
Coil
Panel
Body
Pipe connections
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop
TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe
V/Ph/Hzm3/hCFMkWL/hkPakWkPaWW
dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
1000/850/720590/500/4205.7/4.73/3.96
980 23.8
9.66/7.72/6.2716.4
125/84/742100
45/41/36
840×230×840900×260×900
25/2730/32
220-240/1/501250/1060/900
740/620/5307/5.62/4.72
1204 25.2
11.55/9.24/7.5111.8
130/102/932100
46/42/37Low noise 3-speed fan motor
1Centrifugal, forward-curved blades
12
1.6Φ7
950×45×9501035×90×1035
69
840×230×840900×260×900
25/2730/32RC3/4
ODΦ32
1400/1190/1010820/700/590
7.27/6.46/5.711250
2712.42/9.93/8.07
14.6150/124/106
285047/43/38
840×300×840900×330×900
30.5/3336.2/39
ModelNon-AEH MKA-600R MKA-750R MKA-850RWith-AEH MKA-600RA MKA-750RA MKA-850RA
Power supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Auxiliary electric heater (AEH)Sound pressure level (H/M/L)Fan motor
Fan
Coil
Panel
Body
Pipe connections
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop
TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe
V/Ph/Hzm3/hCFMkWL/hkPakWkPaWW
dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
1600/1360/1150940/800/680
8.22/7.39/6.541414 31.2
13.85/11.08/914.8
155/131/1062850
48/44/39
2
30.5/3336.2/39
220-240/1/502000/1700/14401180/1000/85010.39/9.25/8.2
1787 44
17.58/14.06/11.4234.7
190/127/1092850
49/45/40Low noise 3-speed fan motor
1Centrifugal, forward-curved blades
12
1.6Φ7
950×45×9501035×90×1035
69
840×300×840900×330×900
30.5/3336.2/39RC3/4
ODΦ32
2550/2170/18401500/1280/108012.9/11.51/10.21
2219 40
17.6/14.08/11.4436.7
190/136/109/
50/46/41
3
31.836
ModelNon-AEH MKA-950R MKA-1200R MKA-1500RWith-AEH MKA-950RA MKA-1200RA /
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
43 44
4-Pipe 4-Way Cassette 2-Pipe Compact 4-Way Cassette
4-Pipe Compact 4-Way Cassette
Model
Power supply
Air flow (H/M/L)
Cooling
Heating
Power input (H/M/L)
Sound pressure level (H/M/L)
Fan motor
Fan
Coil
Panel
Body
Pipe
connections
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
V/Ph/Hz
m3/h
CFM
kW
L/h
kPa
kW
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
mm
mm
kg
kg
inch
mm
MKD-300
510/440/360
300/260/210
3/2.58/2.16
516
14
4/3.5/3.08
12
50/40/30
36/33/28
MKD-400
220-240/1/50
680/580/480
400/340/280
3.7/3.18/2.66
636
15
5.1/4.3/3.83
13
70/50/40
42/39/32
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
1
2
1.6
Φ7
647×50×647
715×123×715
2.5
4.5
575×261×575
670×290×670
16.5
20
G3/4
ODΦ25
MKD-500
850/730/600
500/430/350
4.5/3.6/3.06
774
16
6/4.76/4.07
15
95/53/42
45/42/34
ModelPower supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Sound pressure level (H/M/L)Fan motor
Fan
Coil
Panel
Body
Pipe connections
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water flow rateWater pressure drop
TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight Gross weightWater inlet/outlet pipeDrain pipe
V/Ph/Hzm3/hCFMkWL/hkPakWL/hkPaW
dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
MKA-600F
1150/800/690680/470/4105.1/4.08/3.76
877 15
6.67/5.87/5.07574 37
170/120/8542/32/26
MKA-750F220-240/1/50
1460/1020/880860/600/510
5.93/4.41/3.941020
177.87/6.85/5.9
677 41
188/135/9044/34/28
Low noise 3-speed fan motor1
Centrifugal, forward-curved blades12
1.6Φ7
950×45×9501035×90×1035
69
840×300×840900×307×900
3541
Cold water: RC3/4; Hot water: RC1/2ODΦ32
MKA-850F
1480/1040/890870/610/520
6.17/5.13/4.591061
208.06/6.93/6.05
693 39
198/140/10046/36/30
ModelPower supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Sound pressure level (H/M/L)Fan motor
Fan
Coil
Panel
Body
Pipe connections
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water flow rateWater pressure drop
TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight Gross weightWater inlet/outlet pipeDrain pipe
V/Ph/Hzm3/hCFMkWL/hkPakWL/hkPaW
dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
MKD-300S
510/440/360300/260/2102.5/2.2/1.76
430 22
3.7/3.29/2.92318 17
50/40/3036/33/28
MKD-400S220-240/1/50680/580/480400/340/2802.9/2.55/2.04
499 16
4.6/3.82/3.4396 23
70/50/4042/39/32
Low noise 3-speed fan motor1
Centrifugal, forward-curved blades12
1.6Φ7
647×50×647715×123×715
2.54.5
575×261×575655×290×655
16.520
Cold water: G3/4; Hot water: G1/2ODΦ25
MKD-500S
850/730/600500/430/3503.5/2.87/2.15
602 24
5.1/4.03/3.52439 27
95/65/5045/42/34
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 70°C, temperature drop 10°C DB, entering air temperature 20°C DB.3. Noise is tested in a semi-anechoic test room.
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions(2 pipe): entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions. Heating conditions(4 pipe): entering water 70°C, temperature drop 10°C DB, entering air temperature 20°C DB.3. Noise is tested in a semi-anechoic test room.
ModelPower supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Sound pressure level (H/M/L)Fan motor
Fan
Coil
Panel
Body
Pipe connections
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water flow rateWater pressure drop
TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight Gross weightWater inlet/outlet pipeDrain pipe
V/Ph/Hzm3/hCFMkWL/hkPakWL/hkPaW
dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
MKA-950F
1720/1200/10301010/700/6106.7/5.48/4.85
1152 22
8.67/7.63/6.59746 42
205/145/10547/38/32
2
3541
MKA-1200F220-240/1/50
1860/1300/11101090/760/6509.28/7.45/6.5
1596 32
11.65/10.49/8.851002
57197/135/103
48/40/34Low noise 3-speed fan motor
1Centrifugal, forward-curved blades
13
1.6Φ7
950×45×9501035×90×1035
69
840×300×840900×307×900
3844
Cold water: RC3/4; Hot water: RC1/2ODΦ32
MKA-1500F
2100/1470/12601230/860/74010.58/7.45/6.5
1820 38
12.62/11.36/9.471085
61234/165/115
50/42/36
3
3844
45 46
Duct SeriesVarious Selections
Versions for 2/4 pipe systems.
Versions for normal/large temperature difference systems.
2, 3 or 4 rows coil for 2-pipe systems.
Large range of available static pressure.
Wired controller is optional.
Four fan speeds are avaliable: low, medium, high and one reserved for more choice.
High E�ciency
Standard Return Air Plenum and Filter
Fresh air can enter through the duct unit so you can enjoy even
fresher air in a room.
Fresh Air Intake
Left and right hand piping connections are optional, flexible installation.
Flexible Installation
Duct
High Static Pressure Duct
District Cooling Duct
Standard return air plenum and filter guarantees clean air supply and stable air flow rate.
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Highly efficient heat exchange for complete contranatant flow.
Left hand Right handFront discharge
47 48
2-Row Duct 3-Row Duct
Non-AEH
With-AEHPower supplyAir flow (H/M/L)
Standard external static pressureCooling
Heating
Power input
Auxiliary electric heater (AEH)Sound pressure levelFan motor
Fan
Coil
Net dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop12Pa (H/M/L)30Pa (H/M/L)
12Pa (H/M/L)30Pa (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameter
V/Ph/Hzm3/hCFMPakWL/hkPakWkPaWWW
dB(A)dB(A)
MPammmmmmkgkg
inchinch
340/255/170200/150/100
2.2/1.9/1.68378 14
3.5/3.08/2.5910.5
33/25/2249/37/33
55035/32/2641/37/31
1
741×241×522790×260×550
14.6/16.116.9/18.4
510/385/255300/225/150
3.1/2.7/2.3533 26
5.3/4.61/3.9821.8
53/41/3564/49/42
65036/33/2742/38/32
2
841×241×522890×260×550
17/18.519.5/21
220-240/1/50680/510/340400/300/200
G12 models: 12; G30 models: 304/3.4/2.95
688 18
6.8/5.85/5.116.9
66/53/4875/61/54
110037/34/2843/39/33
Low noise 3-speed fan motor1
Centrifugal, forward-curved blades23
1.6Φ9.52
941×241×522990×260×550
20.2/21.722.6/24.1
RC3/4R3/4
850/640/425500/375/250
4.6/3.96/3.45791 24
7.9/6.95/622.3
87/53/4493/56/47
110040/36/3044/40/34
2
941×241×522990×260×550
20.2/21.722.6/24.1
1020/765/510600/450/300
5.8/4.88/4.45998 36
9.8/8.6/7.431.6
100/65/55114/74/63
160042/38/3245/41/35
2
1161×241×5221210×260×550
23/2526/28
MKT3-200G12MKT3-200G30
MKT3-200EG30
MKT3-300G12MKT3-300G30
MKT3-300EG30
MKT3-400G12MKT3-400G30
MKT3-400EG30
MKT3-500G12MKT3-500G30
MKT3-500EG30
MKT3-600G12MKT3-600G30
MKT3-600EG30Model
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.
Non-AEH
With-AEHPower supplyAir flow (H/M/L)
Standard external static pressureCooling
Heating
Power input
Auxiliary electric heater (AEH)Sound pressure levelFan motor
Fan
Coil
Net dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop12Pa (H/M/L)30Pa (H/M/L)
12Pa (H/M/L)30Pa (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameter
V/Ph/Hzm3/hCFMPakWL/hkPakWkPaWWW
dB(A)dB(A)
MPammmmmmkgkg
inchinch
MKT3-800G12MKT3-800G30
MKT3-800EG30
MKT3-1000G12MKT3-1000G30
MKT3-1000EG30
MKT3-1200G12MKT3-1200G30
MKT3-1200EG30
MKT3-1400G12MKT3-1400G30
MKT3-1400EG30Model
1360/1020/680800/600/400
8.2/6.88/6.251410
3913.6/11.97/10.2
33.8145/121/108154/129/114
220043/39/3346/42/36
1461×241×5221510×260×550
31.9/34.435.5/38
1700/1275/8501000/750/500
9/7.8/6.571548
3216/14.24/12
30.7180/114/97180/114/97
220045/41/3547/43/37
1566×241×5221615×260×550
34.4/37.438.1/41.1
2040/1530/10201200/900/600
11/9.8/8.351892
3920.1/18.27/15.43
34.6210/140/120220/147/126
320046/42/3648/44/38
1856×241×5221905×260×550
39.5/4343/46.5
2380/1785/11901400/1050/700
12.5/10.8/9.442150
4521/18.7/15.75
40.1222/179/155278/224/194
320048/44/3849/45/39
2022×241×5222070×260×550
43.1/47.148.4/52.4
220-240/1/50
G12 models: 12; G30 models: 30
Low noise 3-speed fan motor2
Centrifugal, forward-curved blades43
1.6Φ9.52
RC3/4R3/4
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Power supplyAir flow (H/M/L)
Standard external static pressureCooling
Heating
Power input
Auxiliary electric heater (AEH)Sound pressure levelFan motor
Fan
Coil
Net dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop12Pa (H/M/L)30Pa (H/M/L)
12Pa (H/M/L)30Pa (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameter
V/Ph/Hzm3/hCFMPakWL/hkPakWkPaWWW
dB(A)dB(A)
MPammmmmmkgkg
inchinch
340/255/170200/150/100
2/1.74/1.52344
53.2/2.75/2.37
4.231/25/2245/36/32
55036/34/2941/37/31
1
741×241×522790×260×550
13.9/15.416.2/17.7
510/385/255300/225/150
2.7/2.31/2.03464 11
4.3/3.74/3.239.5
50/40/3560/48/42
65038/33/2941/37/32
2
841×241×522890×260×550
16.5/1819/20.5
220-240/1/50680/510/340400/300/200
G12 models: 12; G30 models: 303.6/3.11/2.66
619 19
5.4/4.64/4.0515.5
60/48/4267/54/47
110038/35/3142/39/33
Low noise 3-speed fan motor1
Centrifugal, forward-curved blades22
1.6Φ9.52
941×241×522990×260×550
19.2/20.721.6/23.1
RC3/4R3/4
850/640/425500/375/250
4.4/3.74/3.25757 22
6.8/5.78/5.0718.3
80/64/5689/71/62
110039/36/3245/41/34
2
941×241×522990×260×550
19.2/20.721.6/23.1
1020/765/510600/450/300
5.5/4.58/4.09946 14
8.1/6.77/5.9211.8
97/78/68110/88/77
160040/36/3346/41/35
2
1161×241×5221210×260×550
22/2425/27
MKT2-200G30
MKT2-200EG30
MKT2-300G30
MKT2-300EG30
MKT2-400G30
MKT2-400EG30
MKT2-500G30
MKT2-500EG30
MKT2-600G30
MKT2-600EG30
ModelNon-AEH
With-AEH
Power supplyAir flow (H/M/L)
Standard external static pressureCooling
Heating
Power input
Auxiliary electric heater (AEH)Sound pressure levelFan motor
Fan
Coil
Net dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop12Pa (H/M/L)30Pa (H/M/L)
12Pa (H/M/L)30Pa (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameter
V/Ph/Hzm3/hCFMPakWL/hkPakWkPaWWW
dB(A)dB(A)
MPammmmmmkgkg
inchinch
MKT2-800G30
MKT2-800EG30
MKT2-1000G30
MKT2-1000EG30
MKT2-1200G30
MKT2-1200EG30
MKT2-1400G30
MKT2-1400EG30Model
1360/1020/680800/600/400
7.5/6.33/5.681290
1411/9.48/8.25
12.5140/112/98130/104/91
220042/37/3346/41/36
1461×241×5221510×260×550
30.9/33.434.5/37
1700/1275/8501000/750/500
8.9/7.61/6.411531
2213.5/11.72/10.03
19172/138/120171/137/120
220044/39/3447/43/37
1566×241×5221615×260×550
33.4/36.437/40
2040/1530/10201200/900/600
10.8/9.13/7.931858
3916.5/14.05/12.24
32.6205/164/144212/170/148
320046/40/3548/44/38
1856×241×5221905×260×550
38.5/4242/45.5
2380/1785/11901400/1050/700
12.3/10.46/9.272116
4619.5/16.85/14.63
40.1216/173/151249/200/174
320048/42/3749/44/39
2022×241×5222070×260×550
42.1/46.147.5/51.5
220-240/1/50
G12 models: 12; G30 models: 30
Low noise 3-speed fan motor2
Centrifugal, forward-curved blades42
1.6Φ9.52
RC3/4R3/4
Non-AEH
With-AEH
49 50
4-Row Duct A4 Type Duct
Model
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Heating
Power input (H/M/L)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
kW
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
MKT4-200G30
340/255/170
200/150/100
2.5/2.16/1.87
430
2.6
4.1/3.51/3.03
2.2
50/40/35
37/33/27
1
1
741×241×522
790×260×550
15.3
17.6
MKT4-300G30
510/385/255
300/225/150
3.3/2.85/2.47
568
5
5.8/5.05/4.35
4.2
65/52/46
38/34/28
1
2
841×241×522
890×260×550
17.5
20
MKT4-400G30
680/510/340
400/300/200
4.4/3.72/3.22
757
8.1
7.1/6.11/5.33
6.9
80/64/56
38/35/29
1
2
941×241×522
990×260×550
20.7
23.1
MKT4-500G30
850/640/425
500/375/250
4.8/4.18/3.64
826
9.8
8.5/7.04/6.28
8.1
98/78/69
40/35/30
1
2
941×241×522
990×260×550
20.7
23.1
MKT4-600G30
1020/765/510
600/450/300
6.2/5.38/4.65
1066
15.4
10.5/9.03/7.77
12.7
110/88/77
41/36/31
1
2
1161×241×522
1210×260×550
23.5
26.5
MKT4-800G30
1360/1020/680
800/600/400
8.8/7.43/6.57
1514
12.3
14.5/12.38/10.88
10
155/124/109
42/37/32
2
4
1461×241×522
1510×260×550
32.9
36.5
220-240/1/50
50
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
2
1.6
Φ9.52
1180x340x612
1310x380x693
RC3/4
R3/4
Model
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Heating
Power input (H/M/L)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
kW
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
MKT3-800G50-A4
1500/1412/1265
882/831/745
6.97/6.66/6.28
1198
19.0
9.57/9.09/8.43
16.9
151/130/111
49.7/47.8/45.6
3
38.3
47.2
MKT4-800G50-A4
1400/1342/1200
824/790/706
7.92/7.56/7.09
1363
13.5
10.42/9.89/9.12
39.7
144/124/105
48.4/47.9/46.6
4
39.3
47
MKT3-1000G50-A4
1700/1664/1554
1000/980/915
7.77/7.58/7.33
1336
24.5
10.61/10.25/9.82
21.1
174/147/130
50.1/48/45.8
3
39.8
48.6
MKT4-1000G50-A4
1650/1527/1405
970/900/827
8.15/7.93/7.54
1402
21.4
11.25/10.72/10.06
23.3
176/146/128
49.5/48.1/47.3
4
40.8
49.6
Model
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Heating
Power input (H/M/L)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
kW
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
MKT4-1200G30
2040/1530/1020
1200/900/600
30
11.8/9.82/8.74
2030
21.2
16.5/14.05/12.23
17.6
220/176/154
45/40/34
2
4
1856×241×522
1905×260×550
40.5
44
MKT4-1400G30
2380/1785/1190
1400/1050/700
30
13/11.23/9.83
2236
24.7
17/14.31/12.69
20.8
275/220/193
47/42/36
2
4
2022×241×522
2070×260×550
44.1
49.4
MKT4-1500
2550/2100/1300
1500/1240/760
30
13.5/11.5/10.1
2322
11.5
17.5/14.9/13.2
10
236/189/165
48/44/39
1
2
1369×342×612
1421×381×619
46
49.8
MKT4-2000
3400/2550/1700
2000/1500/1000
30
18/15.3/13.5
3096
26.2
23.4/19.8/17.5
24.3
360/288/252
50/46/41
1
3
1500×342×612
1552×381×619
57
61
220-240/1/50
Low noise 3-speed fan motor
Centrifugal, forward-curved blades
4
1.6
Φ9.52
RC3/4
R3/4
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.
Model
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Heating
Power input (H/M/L)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
kW
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
MKT4-1200G50-A4
2040/1851/1666
1200/1090/981
10.8/10.17/9.55
1890
27.8
14.3/13.23/12.22
24.8
320/284/250
50.9/50/48.5
2
1369x340x612
1490x380x693
46.3
56.4
MKT4-1400G50-A4
2420/1851/1666
1424/1090/981
12.14/10.17/9.55
2089
32.5
16.08/13.23/12.22
29.2
392/284/250
51.7/50/49.5
2
1369x340x612
1490x380x693
46.3
56.4
MKT4-1600G50-A4
220-240/1/50
2430/1917/1742
1431/1128/1025
50
12.19/10.54/9.87
2096
33.4
16.55/13.83/12.9
30.0
482/338/296
52.9/50.7/50
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
2
4
1.6
Φ9.52
1369x340x612
1490x380x693
46.3
56.4
RC3/4
R3/4
MKT4-1800G50-A4
3380/2239/1878
1990/1318/1105
16.16/12.35/11.01
2779
58.3
21.7/15.79/13.91
52.3
538/358/308
53.6/51.1/50.2
3
1500x340x612
1620x380x693
54.8
64.6
MKT4-2000G50-A4
3670/2544/2199
2160/1497/1294
17.34/13.75/12.44
2983
61.5
23.4/17.92/16.08
52.9
583/387/334
54.4/52.7/51.6
3
1500x340x612
1620x380x693
54.8
64.6
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
MKT4-1000G30
1700/1275/850
1000/750/500
30
9.5/8.18/7.06
1634
18
16.3/13.45/12.05
15.4
180/144/126
44/39/33
2
4
1566×241×522
1615×260×550
35.4
39.1
220-240/1/50
30
Low noise 3-speed fan motor
Centrifugal, forward-curved blades
4
1.6
Φ9.52
RC3/4
R3/4
51 52
High Static Pressure Duct District Cooling Duct
220-240/1/50
70
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
1
1.6
Φ9.52
946×400×816
Left connection: 1075×480×857/1075×480×925 Right connection: 1015×480×857/1015×480×925
RC3/4
R3/4
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Heating
Power input (H/M/L)
Auxiliary electric heater (AEH)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (non-AEH/with-AEH)(W×H×D)
Net weight (non-AEH/with-AEH)
Gross weight (non-AEH/with-AEH)
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
kW
kPa
W
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
1360/1220/1090
800/720/640
6.6/6.37/6.12
1135
8
9.7/8.54/7.18
8.4
320/300/285
5000
49/42/35
2
50/53
55/58
1700/1530/1380
1000/900/810
8.8/8.19/7.57
1514
24
13.2/11.48/9.9
25
350/320/300
5000
50/43/36
3
52/55
57/60
2040/1880/1610
1200/1105/950
10/9.44/8.53
1720
24
15/12.9/11.25
23.4
350/320/290
5000
51/44/37
3
52/55
57/60
2380/2120/1860
1400/1250/1095
12/11.47/10.24
2064
36
17.9/15.75/13.6
34.2
350/300/285
5000
52/45/38
4
54/57
59/62
Non-AEH MKT3H-800G70 MKT3H-1000G70 MKT3H-1200G70 MKT3H-1400G70
With-AEH MKT3H-800EG70 MKT3H-1000EG70 MKT3H-1200EG70 MKT3H-1400EG70Model
Model
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Power input (H/M/L)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
MKS4-200G30
430/380/340
253/224/200
30
2.05/1.742/1.55
196
10
47/38/33
38/33/27
1
741×241×522
790×260×550
15.3
17.6
MKS4-300G30
600/540/480
353/318/282
30
2.61/2.21/1.98
249
10
65/52/46
39/34/28
2
841×241×522
890×260×550
17.5
20
MKS4-400G30
700/630/520
412/370/305
30
4.03/3.42/3.06
385
21
78/62/55
39/35/29
2
941×241×522
990×260×550
20.7
23.1
MKS4-500G30
900/810/720
530/476/424
30
4.57/3.88/3.47
437
25
92/74/64
41/35/30
2
941×241×522
990×260×550
20.7
23.1
MKS4-600G30
1160/1040/930
682/612/547
30
6.39/5.43/4.85
610.6
53.8
116/93/81
42/36/31
2
1161×241×522
1210×260×550
23.5
26.5
MKS4-800G50-A4
1400/1342/1200
824/789/705
50
6.93/5.89/5.26
662
13.3
144/115/101
48/47/46
2
1180x340x612
1310x380x693
39.3
47
220-240/1/50
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
4
1.6
Φ9.52
RC3/4
R3/4
Non-AEH MKT3H-1600G100 MKT3H-1800G100 MKT3H-2200G100
With-AEH MKT3H-1600EG100 MKT3H-1800EG100 MKT3H-2200EG100
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Heating
Power input (H/M/L)
Auxiliary electric heater (AEH)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (non-AEH/with-AEH)(W×H×D)
Net weight (non-AEH/with-AEH)
Gross weight (non-AEH/with-AEH)
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
kW
kPa
W
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
2720/2450/2170
1600/1440/1280
14.1/13.03/11.87
2425
52
21.2/18.23/15.69
51
550/520/500
9500
54/47/40
220-240/1/50
3060/2750/2450
1800/1620/1440
100
15.8/14.6/13.46
2718
90
23.8/20.94/17.85
85
800/680/620
9500
60/53/46
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
2
3
1.6
Φ9.52
1290×400×809
Left connection: 1448×460×877/1448×460×950, Right connection: 1383×422×877/1368×460×950
76/82
83/89
RC3/4
R3/4
3740/3360/2990
2200/1980/1760
19.9/18.58/17.24
3423
130
30/26.7/22.5
121
950/860/760
9500
61/54/47
Model
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 5.5°C, temperature rise 9°C, entering air temperature 27°C DB/19°C WB.4. Noise is tested in a semi-anechoic test room.
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Model
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Power input (H/M/L)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
220-240/1/50
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
4
1.6
Φ9.52
RC3/4
R3/4
MKS4-1000G50-A4
1650/1527/1405
970/898/826
50
7.57/6.43/5.75
723
16.3
176/141/123
49/48/47
2
1180x340x612
1310x380x693
40.8
49.6
MKS4-1200G50-A4
2040/1851/1666
1200/1089/980
50
10.11/8.59/7.68
966
21
320/256/224
51/50/48
2
1369x340x612
1490x380x693
46.3
56.4
MKS4-1400G50-A4
2420/1850/1657
1424/1088/975
50
11.5/9.7/8.74
1099
25.3
392/314/274
52/50/49
2
1369x340x612
1490x380x693
46.3
56.4
MKS4-1600G50-A4
2430/1917/1742
1431/1128/1025
50
11.74/9.97/8.92
1122
27.8
482/386/337
53/51/50
2
1369x340x612
1490x380x693
46.3
56.4
MKS4-1800G50-A4
3380/2239/1878
1988/1317/1105
50
14.74/12.52/11.2
1408
37.9
538/430/376
54/51/50
3
1500x340x612
1620x380x693
54.8
64.6
MKS4-2000G50-A4
3660/2544/2199
2153/1496/1295
50
16.1/13.68/12.23
1538
48.1
583/466/408
54/52/51
3
1500x340x612
1620x380x693
54.8
64.6
53 54
4-Pipe Duct4-Pipe Duct
Model
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Heating
Power input
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water flow rate
Water pressure drop
12Pa (H/M/L)
30Pa (H/M/L)
12Pa (H/M/L)
30Pa (H/M/L)
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
kW
L/h
kPa
W
W
dB(A)
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
Sound pressure level
340/255/170
200/150/100
2/1.76/1.52
344
7.6
3/2.64/2.22
258
6.8
33/26/23
49/39/34
35/32/26
41/37/31
1
741×241×522
790×260×550
15.1
17.4
510/385/255
300/225/150
2.7/2.35/2.13
464
14.4
4/3.48/3
344
12.5
53/38/31
64/50/42
36/33/27
42/38/32
2
841×241×522
890×260×550
17.5
20
680/510/340
400/300/200
3.6/3.15/2.76
619
8.2
5.2/4.47/3.9
447
23.5
66/48/42
75/55/48
37/34/28
43/39/33
2
941×241×522
990×260×550
20.7
23.1
850/640/425
500/375/250
4.3/3.74/3.32
740
9.5
5.7/5.02/4.33
490
24.0
87/54/44
96/58/48
40/36/30
44/40/34
2
941×241×522
990×260×550
20.7
23.1
1020/765/510
600/450/300
5/4.32/3.84
860
17.2
7.2/6.19/5.33
619
40.7
100/67/56
114/76/64
42/38/32
45/41/35
2
1161×241×522
1210×260×550
23.5
26.5
220-240/1/50
G12 models: 12; G30 models: 30
Low noise 3-speed fan motor
1
Centrifugal, forward-curved blades
3
1.6
Φ9.52
RC3/4
R3/4
MKT3-200FG30 MKT3-300FG30 MKT3-400FG30 MKT3-500FG30 MKT3-600FG30 Model
Power supply
Air flow (H/M/L)
Standard external static pressure
Cooling
Heating
Power input
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water flow rate
Water pressure drop
12Pa (H/M/L)
30Pa (H/M/L)
12Pa (H/M/L)
30Pa (H/M/L)
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
Pa
kW
L/h
kPa
kW
L/h
kPa
W
W
dB(A)
dB(A)
MPa
mm
mm
mm
kg
kg
inch
inch
Sound pressure level
220-240/1/50
G12 models: 12; G30 models: 30
Low noise 3-speed fan motor
2
Centrifugal, forward-curved blades
4
3
1.6
Φ9.52
RC3/4
R3/4
MKT3-800FG30 MKT3-1000FG30 MKT3-1200FG30 MKT3-1400FG30
1360/1020/680
800/600/400
6.8/5.78/5.11
1170
18.8
9.6/8.45/7.2
826
20.7
145/130/111
154/132/113
43/39/33
46/42/36
1461×241×522
1510×260×550
32.4
36
1700/1275/850
1000/750/500
7.8/6.74/5.88
1342
30.0
10.8/9.61/8.1
929
34.7
180/104/88
193/114/97
45/41/35
47/43/37
1566×241×522
1615×260×550
34.9
38.6
2040/1530/1020
1200/900/600
10.2/8.89/7.85
1754
40.3
13.5/12.15/10.26
1161
28.6
210/140/123
230/157/131
46/42/36
48/44/38
1856×241×522
1905×260×550
40
43.5
2380/1785/1190
1400/1050/700
11.5/9.9/8.86
1978
51.9
15.5/13.48/11.78
1333
55.2
222/201/182
278/262/228
48/44/38
49/45/39
2022×241×522
2070×260×550
43.6
48.9
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 70°C, temperature drop 10°C DB, entering air temperature 20°C DB.4. Noise is tested in a semi-anechoic test room.
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 70°C, temperature drop 10°C DB, entering air temperature 20°C DB.4. Noise is tested in a semi-anechoic test room.
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
55 56
Stylish front panel blends easily within any interior décor, ideal for use in shops, restaurants or offices with no or narrow false
ceilings.
Stylish Panel
Wall Mounted (C Type)
Wall Mounted (S Type)Built-in 3-Way Electromagnetic Valve
Auto Swing Louver
Easy Maintenance
Multi-directional outlet pipe feature: left\right\rear, to meet the needs of different rooms.
The Auto Swing Louver function ensures that the air direction corresponds to the mode selected.
Removable front panel making maintenance convenient.
Convenient Installation
C Type S Type
Rear
Right Left
1
2
3
4
Step
Swing
Model
Power supply
Air flow (H/M/L)
Cooling
Heating
Power input (H/M/L)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
kW
L/h
kPa
kW
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
mm
MKG-250
425/360/320
250/210/190
2.2/1.84/1.65
378
12
3.02/2.6/2.23
10
28/22/20
30/24/20
915×290×210
1020×385×300
12
16
MKG-300
510/430/380
300/250/220
2.64/2.24/2.05
454
18
3.69/3.25/2.77
16.4
40/32/28
35/29/24
915×290×210
1020×385×300
12
16.7
MKG-400
220-240/1/50
680/580/510
400/340/300
3.08/2.62/2.27
530
22
4.34/3.86/3.25
20.8
44/35/31
37/31/26
Low noise 3-speed fan motor
1
Tangential fan
1
2
1.6
Φ7
915×290×210
1020×385×300
12
17
G3/4
ODΦ20
MKG-500
850/720/640
500/420/380
4.07/3.73/3.24
700
26
5.69/5.12/4.32
25.1
50/40/35
39/33/28
1070×315×210
1180×410×300
15
19
MKG-600
1020/870/770
600/510/450
4.45/4.18/3.74
765
29
6.3/5.67/4.73
27.9
60/48/42
40/34/29
1070×315×210
1180×410×300
15
19
Model
Power supply
Air flow (H/M/L)
Cooling
Heating
Power input (H/M/L)
Sound pressure level
Fan motor
Fan
Coil
Net dimensions (W×H×D)
Packing size (W×H×D)
Net weight
Gross weight
Water inlet/outlet pipe
Drain pipe
Capacity (H/M/L)
Water flow rate
Water pressure drop
Capacity (H/M/L)
Water pressure drop
Type
Quantity
Type
Quantity
Row
Max. working pressure
Diameter
V/Ph/Hz
m3/h
CFM
kW
l/h
kPa
kW
kPa
W
dB(A)
MPa
mm
mm
mm
kg
kg
inch
mm
MKG-250-B
425/390/350
250/230/205
2.63/2.41/2.16
452
29.4
3.36/3.1/2.79
27.3
24/19/17
30/24/20
915×290×230
1020×390×315
13
16.3
MKG-300-B
510/470/390
300/275/230
2.97/2.47/2.12
511
35.6
3.91/3.26/2.77
32.9
37/29/26
35/29/24
915×290×230
1020×390×315
13
16.3
MKG-400-B
220-240/1/50
680/550/460
400/325/270
3.28/2.83/2.41
564
43.5
4.37/3.73/3.17
40.8
40/32/28
37/31/26
Low noise 3-speed fan motor
1
Tangential fan
1
2
1.6
Φ7
915×290×230
1020×390×315
13.3
16.7
G3/4
ODΦ20
MKG-500-B
850/745/620
500/440/365
4.25/3.85/3.32
731
31.8
5.81/5.17/4.43
30.2
50/40/35
39/33/28
1072×315×230
1180×415×315
15.8
19.4
MKG-600-B
1020/915/780
600/540/460
5/4.47/3.97
860
42.5
6.7/6/5.28
39.7
66/53/46
40/34/29
1072×315×230
1180×415×315
15.8
19.4
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.
Wall Mounted Series
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
57 58
Flexible Installation
Floor-standing
Flexible Air Return Type
Removable Louver
Cabinet and concealed versions meet various installation requirements.
Horizontal or vertical installation.
Air can return from front or bottom of the unit.
Removable louver for easy maintenance.
Concealed TypeF3/H3 Series
Exposed Type (air return from side)
F4/H4 Series
Exposed Type (air return from bottom)
F5/H5 Series
Power supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Sound pressure level
Fan motor
Fan
Coil
Body (F3 series)
Body (F4/F5 series)
Water inlet/outlet pipeDrain pipe
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop
F3 (H/M/L)F4 (H/M/L)F5 (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weight
V/Ph/Hzm3/hCFMkWL/hkPakWkPaW
dB(A)dB(A)dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
255/215/190150/125/110
1.15/0.93/0.89198 18.3
2.54/2.24/1.8816
27/22/1930/27/2432/29/2630/27/24
13
550×545×212639×639×305
1719
800×592×225889×683×312
22.5/22.526.5/26.5
425/360/320250/210/190
1.87/1.74/1.59322 10.1
4.17/3.36/3.138.8
29/23/2033/30/2835/32/3033/30/28
13
550×545×212639×639×305
1719
800×592×225889×683×312
22.5/22.526.5/26.5
510/430/380300/250/220
2.53/2.25/1.88435 14.2
5.64/4.85/4.2313.7
40/32/2835/32/3037/34/3235/32/30
22
750×545×212839×639×305
2023.5
1000×592×2251089×683×312
26/2631/31
680/580/510400/340/300
3.27/2.84/2.54562 26.3
7.22/6.35/5.4924
46/37/3237/34/3239/36/3437/34/32
22
750×545×212839×639×305
2023.5
1000×592×2251089×683×312
26/2631/31
220-240/1/50
Low noise 3-speed fan motor1
Centrifugal, forward-curved blades
1.6Φ9.52
G3/4ODΦ16
MKF3-150MKF4-150MKF5-150
MKF3-250MKF4-250MKF5-250
MKF3-300MKF4-300MKF5-300
MKF3-400MKF4-400MKF5-400
Model
Power supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Sound pressure level
Fan motor
Fan
Coil
Body (F3 series)
Body (F4/F5 series)
Water inlet/outlet pipeDrain pipe
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop
F3 (H/M/L)F4 (H/M/L)F5 (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weight
V/Ph/Hzm3/hCFMkWL/hkPakWkPaW
dB(A)dB(A)dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
MKF3-450MKF4-450MKF5-450
MKF3-500MKF4-500MKF5-500
MKF3-600MKF4-600MKF5-600
MKF3-800MKF4-800MKF5-800
MKF3-900MKF4-900MKF5-900
Model
765/650/570450/380/335
3.97/3.58/3.15683 23.1
8.85/7.61/6.5522
39/31/2739/36/3441/38/3639/36/34
23
950×545×2121039×639×305
2529
1200×592×2251289×683×312
32.5/32.538/38
850/720/640500/420/375
4.85/4.41/3.72834 20
10.28/9.05/7.7117.4
49/39/3441/38/3643/40/3841/38/36
23
950×545×2121039×639×305
2529
1200×592×2251289×683×312
32.5/3538/40
220-240/1/501020/870/765600/510/450
5.64/5.02/4.46970 11.4
12.24/10.89/9.1810
63/50/4442/39/3744/41/3942/39/37
Low noise 3-speed fan motor1
Centrifugal, forward-curved blades32
1.6Φ9.52
1250×545×2121339×639×305
3236
1500×592×2251589×683×312
39/36.645/42.6
G3/4ODΦ16
1360/1160/1020800/680/600
6.52/5.75/4.361121
2115.35/13.82/11.67
20.288/70/6244/41/3846/43/4044/41/38
32
1250×545×2121339×639×305
3236
1500×592×2251589×683×312
39/3945/45
1530/1300/1150900/760/675
7.85/7.19/6.551350 24.3
18.2/16.38/13.6521.5
137/109/9646/43/4048/45/4246/43/40
32
1250×545×2121339×639×305
3236
1500×592×2251589×683×312
39/3945/45
Ceiling installationFloor installation
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.
Floor-standing / Ceiling&Floor Series
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
59 60
Ceiling&Floor
680(
Hoo
k-lo
catio
n)
840(
Body
)
950(
Pane
l)
780(Hook-location)
840(Body)950(Panel)
4-Pipe 4-way cassetteDimensions (unit: mm)
Service Space (unit: mm)
>1000
>1000
>10
00
>10
00
Ceiling
600mm (ceiling hole)
Ground
PanelInletOutlet Outlet880 (ceiling hole)
>25
00
Water pipe jointDrain pipe joint
Ceiling
880 (ceiling hole)
Ground
PanelInletOutlet Outlet
4000
~25
00
Water pipe jointDrain pipe joint
>33
0
Ceiling
Ground
InletOutlet
4-pipe 4-way cassette
300
190
220
160
210
680(
Hoo
k-lo
catio
n)
840(
Body
)
950(
Pane
l)
780(Hook-location)840(Body)
950(Panel)
Drain sideTubing side
2-pipe 4-way cassetteDimensions (unit: mm)
B A
C D
300 190 145 195
SizeModel
230 170 135 185
A B C D
MKA-950R(A)MKA-1200R(A)MKA-1500R
MKA-600R(A)MKA-750R(A)
2-pipe 4-way cassette
Power supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Sound pressure level
Fan motor
Fan
Coil
Body (H3 series)
Body (H4/H5 series)
Water inlet/outlet pipeDrain pipe
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop
H3 (H/M/L)H4 (H/M/L)H5 (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weight
V/Ph/Hzm3/hCFMkWL/hkPakWkPaW
dB(A)dB(A)dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
255/215/190150/125/110
1.15/0.93/0.89198 18.3
1.52/1.22/1.1416
27/22/1930/27/2432/29/2630/27/24
13
550×545×212795X640X305
1719
800×592×225982X683X326
22.5/22.526.5/26.5
425/360/320250/210/190
1.87/1.74/1.59322 10.1
2.53/2.28/2.18.8
29/23/2033/30/2835/32/3033/30/28
13
550×545×212795X640X305
1719
800×592×225982X683X326
22.5/22.527/26.5
510/430/380300/250/220
2.53/2.25/1.88435 14.2
3.49/2.97/2.4413.7
40/32/2835/32/3037/34/3235/32/30
22
750×545×212995X640X305
2023.5
1000×592×2251182X683X326
26/2631/31
680/580/510400/340/300
3.27/2.84/2.54562 26.3
4.58/3.89/3.4424
46/37/3237/34/3239/36/3437/34/32
22
750×545×212995X640X305
2023.5
1000×592×2251182X683X326
26/2631/31
220-240/1/50
Low noise 3-speed fan motor1
Centrifugal, forward-curved blades
1.6Φ9.52
G3/4ODΦ16
MKH3-150MKH4-150MKH5-150
MKH3-250MKH4-250MKH5-250
MKH3-300MKH4-300MKH5-300
MKH3-400MKH4-400MKH5-400
Model
Power supplyAir flow (H/M/L)
Cooling
Heating
Power input (H/M/L)Sound pressure level
Fan motor
Fan
Coil
Body (H3 series)
Body (H4/H5 series)
Water inlet/outlet pipeDrain pipe
Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop
H3 (H/M/L)H4 (H/M/L)H5 (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weight
V/Ph/Hzm3/hCFMkWL/hkPakWkPaW
dB(A)dB(A)dB(A)
MPammmmmmkgkg
mmmmkgkg
inchmm
MKH3-450MKH4-450MKH5-450
MKH3-500MKH4-500MKH5-500
MKH3-600MKH4-600MKH5-600
MKH3-800MKH4-800MKH5-800
MKH3-900MKH4-900MKH5-900
Model
765/650/570450/380/335
3.97/3.58/3.15683 23.1
5.64/4.79/4.2322
39/31/2739/36/3441/38/3639/36/34
23
950×545×2121195X640X305
2529
1200×592×2251382X683X326
32.5/32.538/38
850/720/640500/420/375
4.85/4.41/3.72834 20
6.98/6.28/5.2317.4
49/39/3441/38/3643/40/3841/38/36
23
950×545×2121195X640X305
2529
1200×592×2251382X683X326
32.5/32.538/38
220-240/1/501020/870/765600/510/450
5.64/5.02/4.46970 11.4
8.23/6.58/5.5910
63/50/4442/39/3744/41/3942/39/37
32
1250×545×2121495X640X305
3236
1500×592×2251682X683X326
39/3945/45G3/4
ODΦ16
1360/1160/1020800/680/600
6.52/5.75/4.361121
219.58/8.14/6.32
20.288/70/6244/41/3846/43/4044/41/38
32
1250×545×2121495X640X305
3236
1500×592×2251682X683X326
39/3945/45
1530/1300/1150900/760/675
7.85/7.19/6.551350 24.3
11.69/10.52/9.3521.5
137/109/9646/43/4048/45/4246/43/40
32
1250×545×2121495X640X305
3236
1500×592×2251682X683X326
39/3945/45
Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.
Dimensions4-way cassette
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Low noise 3-speed fan motor1
Centrifugal, forward-curved blades
Tubing side Drain side
>33
0
82608
61
61 62
2-pipe compact 4-way cassetteDimensions (unit: mm)
Dimensions (unit: mm)
Dimensions (unit: mm)
Dimensions (unit: mm)
4-pipe compact 4-way cassetteDimensions (unit: mm)
30
50 630 570 110
30
30
30
530
655
Cei
ling
hole
wid
th
Pane
l wid
th
695
755
Panel length 1420
Ceiling hole length 1360
645 585 125Panel center65
1015
75
90
210
84
60
CA
D112
65
A 230
Model MKG-250-BMKG-300-BMKG-400-B
MKG-500-BMKG-600-BSize
B
114 D
A
B
D
C
732
915
663
290
892
1072
813
315
Model MKG-250MKG-300MKG-400
MKG-500MKG-600Size
A
B
D
C
915
290
670
725
1070
315
815
88525
42
48
66
290
69
C
290
425
169
MKC-300R(A)-B MKC-400R(A)-B MKC-600HRN4
Tubing sideDrain side
523(
Hoo
k-lo
catio
n)
575(
Body
)
647(
Pane
l)
261
190
124 21
3
261
H
190
124
213
110 15
7
545(Hook-location)
575(Body)
647(Panel)
Tubing sideDrain side
523(
Hoo
k-lo
catio
n)
575(
Body
)
647(
Pane
l)
545(Hook-location)
575(Body)
647(Panel)
Service Space (unit: mm)
Ground Ground2-pipe compact 4-way cassette
Height of the front panel
Type H (mm)
4-way cassette 45
Compact 4-way cassette 50
4-pipe compact 4-way cassette
>1000
>1000
>10
00
>10
00
Outlet600 (ceiling hole)
2300
~28
00
Water pipe joint Drain pipe joint
PanelCeiling
InletOutlet
>30
0
2300
~28
00
Water pipe joint Drain pipe joint
Ceiling
Outlet600 (ceiling hole)
PanelInletOutlet
>30
0
Compact 4-way cassette
1-way cassette
Wall mounted - S type
Wall mounted - C type
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
63 64
0
0
0
0
Model Size
AB
EDC
F
IHG
J
LK
M
900960
910885
1180150195335612342231230340
13271277
130812771500160195335612342231230340
MKT3-800/1000G50-A4
11351085
111210851369160195335612342231230340
MKT4-1200/1400/1500/1600G50-A4
MKT4-1800/2000G50-A4MKT4-800/1000G50-A4J
2-pipe duct 4-pipe duct
F241 241
water inletwater outlet
air release valve
Air release valve
1010140 140
180 180
262
56
58
145
E B
HG
I
170
470 52
2
241
241
180
180
258
258
545
545
126
345
203
291
212
203
345
592
118
178
225
178
74
291
111
178
128
128
AB (Air return)
K (Air return)
FDA
HG
C
Terminal box
4-10×16 hanger slots
4-10×16 hanger slots
C
DE
AB
40 19M
10L
K
EDF
Air filter
Terminal box
Terminal box
C
11650
Drain port
Water inlet RC3/4”
Water outlet RC3/4”
Notes:This figure is for reference only, actual product may differ.The dotted line in the figure is the dimension for air return plenum.Units with air return plenum is standard, unis without air return plenum can be customized.
Air release valve
Drain port ZG3/4”
water inlet RC3/4”
Water outlet RC3/4”
Air release valve
Drain port ZG5/4”
Size
200CFM
300CFM
400CFM
500CFM
600CFM
800CFM
1000CFM
1200CFM
1400CFM
A
545
645
745
745
965
1265
1370
1660
1826
B
485
585
685
685
905
1205
1310
1600
1766
C
513
613
713
713
933
1233
1338
1628
1794
D
485
585
685
685
905
1205
1310
1600
1766
E
741
841
941
941
1161
1461
1566
1856
2022
F
583
683
783
783
1003
1303
1408
1698
1864
Drain portZG3/4” Cold water
inlet RC3/4”Hot waterinlet RC3/4”
Cold wateroutlet RC3/4”
Hot wateroutlet RC3/4”
A
A105 MKF(H)3-150/250
550
526
500
532
MKF(H)3-300/400
750
726
700
732
MKF(H)3-450/500
950
926
900
932
MKF(H)3-600~900
1250
1226
1200
1232
Model
A(mm)
B(mm)
C(mm)
D(mm)
800
584
500
526
1000
784
700
726
1200
984
900
926
1500
1284
1200
1226
Model
A(mm)
B(mm)
C(mm)
D(mm)
192
46
D
B
A
AA
143
B
225
100 100 46 105
106192D
C 150150
140
55
225
592592
C
212 212MKF3 MKH3
Dimensions (unit: mm) Dimensions (unit:mm)
Concealed type
Exposed type
Dimensions (unit:mm)
Model
Size
AB
EDC
F
IHG
JK
816
946
400
778
767
306
219
88
37
338
512
MKT3H-800G70MKT3H-1000G70MKT3H-1200G70MKT3H-1400G70
876
946
400
778
767
306
219
88
97
338
512
MKT3H-800EG70MKT3H-1000EG70MKT3H-1200EG70MKT3H-1400EG70
MKT3H-1600G100MKT3H-1800G100MKT3H-2200G100
809
1290
400
1118
765
900
249
88
39
320
995
MKT3H-1600EG100MKT3H-1800EG100MKT3H-2200EG100
874
1290
400
1118
765
900
249
88
104
320
995
MKF(H)4-150/250MKF(H)5-150/250
MKF(H)4-300/400MKF(H)5-300/400
MKF(H)4-450/500MKF(H)5-450/500
MKF(H)4-600~900MKF(H)5-600~900
Duct
High static pressure duct
Floor-standing / Ceiling&Floor
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
65 66
PC Board Control Kit for FCUWireless Remote ControllersAvailable for all non-PCB FCUs.
Flexibility installation: can be attached to the unit, mounted on a wall or hung under a ceiling.
External installation making maintenance more convenient.
Functions: three fan speeds control, Water pump control, Long-distance ON/OFF control, ALARM function,
electric heater control.
Operating status can be displayed by wired controller lamp indicator.
Centralized control function.
BMS control function through Modbus protocol.
Centralized control
BMS control function through Modbus protocol
X,Y,E
X,Y,E
Centralized controller
X,Y,E X,Y,E
P,Q,E
P,Q,E RS232 Pin hole BMSModbusModbus
USB port
P,Q,E P,Q,E
EPQ R+R-
E
FCUKZ-03 FCUKZ-04
Model
Applicable appliance
Power supply
Operation range
Temp. controlling precision
Net dimension
Packing size
Net weight
Gross weight
Room temp.
Inlet water temp.
W×H×D
W×H×D
V-Ph-Hz
oC
oC
oC
mm
mm
kg
kg
CE-FCUKZ-03
2-pipe FCUs
CE-FCUKZ-04
4-pipe FCUs
220~240-1-50/60
17-30
3-75
±1
296×66×212
410×115×262
1.4
2.5
Model Appearance
R05/BGE
R51/E
Function Descriptions Applicable FCUs
4-way Cassette (standard)
1-way Cassette (standard)
Compact 4-way cassette (standard)
Wall-mounted (standard)
Wired Controllers
Centralized Controllers
LCD display screen
Mode control
Fan speeds control
Time setting / Temp. setting / Swing setting
Model Appearance
KJRP-86A1-E
KJR-18B/E
Function Descriptions Applicable FCUs
Duct without electric heater (optional)
Duct without electric heater (optional)
KJR-21B/D
KJR-15B/E
Duct with electric heater (optional)
Floor-standing / Ceiling&Floor (optional)
LCD display screen
Mode control
Fan speeds control
Timer setting / Temp. setting
Mechanical thermostat
Mode control
Fan speeds control
Temp. setting
LCD display screen
Mode control / Fan speeds control
Electric heater control
Temp. setting
LCD display screen
Mode control
Fan speeds control
Temperature display in oF or oC
KJR-29B Cassette / Wall-mounted (optional)
Receiving remote signal
Mode control
Fan speeds control
Temp. setting
KJR-12B Cassette / Wall-mounted (optional)
Swing function
Mode control
Fan speeds control
Temp. setting
Control Devices Accessories
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Model Appearance
CCM03
CCM09
Function Descriptions Applicable FCUs
CCM30
Large LCD display screen
Max. of 64 FCUs can be controlled by a CCM03
Mode control / fan speed control
Time setting / temp. setting / swing setting
Weekly schedule function
Basic functions are same as CCM03
Touch-style keys
Basic functions are same as CCM03
All FCUs
(1-way cassette and compact 4-way cassette FCUs need
adding NIM01 module, non-PCB FCUs need adding PC
board control kit)
Centralized wiring
Valve KitWorking Voltage: AC230±10%, 50/60Hz (24V can be customized).
Power Consumption: 4W
Nominal Pressure: 1.6MPa
Applied Medium: Cold or hot water, 50% glycol water liquor.
Medium Temperature: 2 - 15°C (DDSTF-01), -20 - 1°C (DDSTF-04/05).
Environment Temperature: -5 - 50°C (DDSTF-01), 0 - 50°C (DDSTF-04/05).
Valve Model
DDSTF-01
DDSTF-04
DDSTF-05
DN(mm)
20
15
20
Inner Screw Thead
3/4”
1/2”
3/4”
Applicable Appliance
2-pipe cassette/duct/floor standing, 4-pipe duct
4-pipe cassette (for hot water)
2-pipe ceiling & floor, 4-pipe cassette (for cold water)
DDSTF-01
DDSTF-04
DDSTF-05
67 68
Application of Central Control & BMS Control
Address setting
LED
XYE terminals
Side port connect to CN20 of FCU PCB
Network Module
Achieve centralized control through XYE connection;
Only available for FCU Cassette Series;
Address setting should be same as connecting FCU;
There LEDs display: operation indicator lamp, communication indicator lamp
and malfunction indicator lamp.
MD-NIM01
BMS gatewayBMS
PC in LAN
BACnetModubusLonWorks
TCP/IP network
LAN
M-interface
Laptop Access
Pad Access
M-net
PC Access
PC
Cloud Servers
InternetRouter
Data converter CCM15
4th generation monitoring system
PCB Kit NIM01
PCB Kit PCB Kit
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts
Centralized controller
XYE XYE XYE XYE XYE
Up to 64 FCUs
CN20 on PCB CN20 on PCB CN20 on PCB CN20 on PCB CN20 on PCB
Note:DDSTF-** is the model of valve. The valve kit includes valve, actuator and conneting pipe. For different model of units, the models of valve kit are different.
Notice:Please note that the PCB kit and Wired Controller( KJR-15B / KJR-18B / KJRP-86A) can not be connected with an Indoor Unit at the same time
69 70
Select by entering air and water conditions as well as fan speed.
Easy to operate interface and visual display.
Powerful project management function.
Features
Main Interface
Selection Interface
Report Data Interface
Selection Software
Fan
Coil
Uni
ts
Fan
Coil
Uni
ts